Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹9,900
Closing Date
16 Oct 2026, 10:55 amClosed
AE/BMCESD/PWD
Kenduadihi, Gobindanagar Hospital campus, Bankura-722102
Annual Maintenance Estimate of the E.I Work at PMSSY -III Building of Bankura Sammilani Medical College and Hospital under BSMC and H Electrical Section -II , P.W.Dte . For the period of the year of 2024-25-------Repair of 2 nos 500 KVA DG set withi
2026_WBPWD_5077431_1
WBPWDTE/AE/BMCESD/NIQ-29/Q of 2026-2027
Open Tender
ELECTRICAL WORKS ORG
Item Wise
14 days
AE/BMCESD /BANKURA
Please refer Tender documents.
3 documents required · 3 mandatory
₹9,900
Yes
16 Oct 2026
5 Oct 2026
19 Oct 2026
5 Oct 2026
16 Oct 2026
5 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Cost for supply, installation, commissioning & testing of Relay board 2.5 Channel, 70 Amp as per sample replacing existing damaged one as per direction of the EIC. | 1 | Each | - | - |
| 2 | Cost for supply, installation, commissioning & testing of Relay board 4 Channel, as per sample replacing existing damaged one as per direction of the EIC. | 1 | Each | - | - |
| 3 | Cost for supply, installation, commissioning & testing of Lucas Starter 9.0 Kw SM50 series for DV engine as per sample replacing existing damaged one as per direction of the EIC. | 1 | Each | - | - |
| 4 | Cost for supply, installation, commissioning & testing of Injector as per sample replacing existing damaged one as per direction of the EIC. | 8 | Each | - | - |
| 5 | Cost for supply, installation, commissioning & testing of Lube oil pressure sensor as per sample replacing existing damaged one as per direction of the EIC. | 1 | Each | - | - |
| 6 | Cost for supply, installation, commissioning & testing of Fuel filter cartridge as per sample replacing existing damaged one as per direction of the EIC. | 4 | Each | - | - |
| 7 | Cost for supply, installation, commissioning & testing of Air cleaner primary element as per sample replacing existing damaged one as per direction of the EIC. | 4 | Each | - | - |
| 8 | Cost for supply, installation, commissioning & testing of Air cleaner safety element as per sample replacing existing damaged one as per direction of the EIC. | 4 | Each | - | - |
| 9 | Cost for supply, installation, commissioning & testing of Lube oil filter as per sample replacing existing damaged one as per direction of the EIC. | 2 | Each | - | - |
| 10 | Cost for supply, installation, commissioning & testing of Lube oil filter (with Kirloskar logo reversal) as per sample replacing existing damaged one as per direction of the EIC. | 2 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.91 MB
2911.pdf
Additional Documents • 0.13 MB
BOQ_5174679.xls
BOQ • 0.29 MB
OID.pdf
Other Document • 0.38 MB
Date_Corrigendum.pdf
PDF • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .