Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.9 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹40.6 L+₹4.7 L (13.2%)Rejected-AOC | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹44.3 L+₹8.4 L (23.3%)Rejected-AOC 64 A JASRAJ MANSION 1ST FLOOR OLD HANUMAN LANE KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹44.6 L+₹8.7 L (24.2%)Rejected-AOC | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹46.2 L+₹10.3 L (28.6%)Rejected-AOC | L5 | Rejected-AOC REJECTED |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
11 Feb 2023, 6:00 pmClosed
GE NW BHANDUP
GE(NW) BAHDNUP, MUMBAI
SPECIAL REPAIRS AND REPLACEMENT OF LT PANELS FEEDER PILLARS AND PROVISION OF CENTRALIZED HOT WATER SUPPLY FOR INLIVING SAILLORS ACCN P-209 DEFFICIENT WATER GEYSERS FOR SS BLOCK BLDG NO. P-95 AND P-144 AT INS HAMLA UNDER GE(NW) BHANDUP
2022_MES_571185_1
8244/B
Open Tender
Civil Works
Item Rate
180 days
HAMLA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(NW) BHANDUP
₹92,000
Yes
28 Mar 2023
24 Dec 2022
13 Feb 2023
24 Dec 2022
11 Feb 2023
28 Jan 2023
Amount
Supply, installing, testing and commissioning factory made and tested LT Panel Indoor type(C.P.R.I Approved), platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system conforming to IS : 375 all as specified herein after. Degree of protection shall not be less than 1P-51 as per IS : 2147 and it shall be suitable to withstand a Fault level of 50 KA (RMS) for one second.hall be dust and vermin proof, and made of 2.00 mm thick Stainless Steel Sheet SS316 thick & suitable frame work/ support made out of MS Iron angle frame, front and Back opening type with space for cable entry from back side of the panel, with proper ferrule & cable gland, internal Connections with Aluminium Bus bars only of adequate size complete. Note :The panel manufacturer should have Govt. Approved CPRI Certification.and The contractor duly shall submit the Manufacturer'S Design and drawings of LT panels before placing the order. Location:- 'B' Zone Sub Station 400 KVA Transformer Outgoing Panel.
Supply, installing, testing and commissioning factory made and tested LT Panel Indoor type(C.P.R.I Approved), platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system conforming to IS : 375 all as specified herein after. Degree of protection shall not be less than 1P-51 as per IS : 2147 and it shall be suitable to withstand a Fault level of 50 KA (rms) for one second.hall be dust and vermin proof, and made of 2.00 mm thick Stainless Steel Sheet SS316 thick & suitable frame work/ support made out of MS Iron angle frame, front and Back opening type with space for cable entry from back side of the panel, with proper ferrule & cable gland, internal Connections with Aluminium Bus bars only of adequate size complete. Note :The panel manufacturer should have Govt. Approved CPRI Certification.and The contractor duly shall submit the Manufacturer'S Design and drawings of LT panels before placing the order. Location:- 'B' Zone Sub Station 200 KVA Transformer Outgoing Panel.
Supply, installing, testing and commissioning factory made and tested LT Panel Outdoor type(C.P.R.I Approved), platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system conforming to IS : 375 all as specified herein after. Degree of protection shall not be less than 1P-42 as per IS : 2147 shall be dust and vermin proof, and made of 2.00 mm thick Stainless Steel Sheet SS316 grade & suitable frame made out of MS Iron angle frame, front and Back opening type with space for cable entry from back side of the panel, with proper ferrule & cable gland, internal Connections Shall be Aluminium Bus bar only if MCCB rating is 100 Amps and above sizes, Copper wiring with PVC FRLS insulated multistranded copper conductor FRLS cable can be done of adequate size for MCCB rated below or equal 63 Amps complete all as specified and directed.(Location P-209 Bldg) Note :The panel manufacturer should have Govt. Approved CPRI Certification.and The contractor duly shall submit the Manufacturer'S Design and drawings of LT panels before placing the order.
The scope of work also comprising of the following:- BUS BAR CHAMBER :- (a) 400 Amp 4 Strips, Aluminium conductor, with color coded(R,Y,B,N) heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings. INSTRUMENT CHAMBER :- (i) Digital Multifunction Meter- 01 Set. (ii) R,Y,B,Phase indicating Lights LED type 220V AC- 1 Set. (Set of three). (iii) Protection MCB 6 A SP C Series- 1 Set. (Set of three). (iv) CT 400/5A Set of -03 INCOMING SUPPLY :- (i) MCCB 200 Amps breaking capacity 35 KA, 4 Pole, 50Hz at 415 Volts, Thermal and Magnetic release with adjustable overload. OUTGOING SUPPLY :- (i) MCCB 63 Amps 25 KA, 4 Pole with Fixed thermal & magnetic release 415 volts , 50Hz = 06 Nos. Note : All MCCB'S shall conform to IS : 13947 (Part 3, 1993) and IEC-60947 (Part 2) with MES Approved List Makes
Supply, installing, testing and commissioning factory made and tested LT Panel Outdoor type(C.P.R.I Approved), platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system conforming to IS : 375 all as specified herein after. Degree of protection shall not be less than 1P-42 as per IS : 2147 shall be dust and vermin proof, and made of 2.00 mm thick Stainless Steel Sheet SS316 grade & suitable frame made out of MS Iron angle frame, front and Back opening type with space for cable entry from back side of the panel, with proper ferrule & cable gland, internal Connections Shall be Aluminium Bus bar only if MCCB rating is 100 Amps and above sizes, Copper wiring with PVC FRLS insulated multistranded copper conductor FRLS cable can be done of adequate size for MCCB rated below or equal 63 Amps complete all as specified and directed.(C zone well Pump Opposite Panel) Note :The panel manufacturer should have Govt. Approved CPRI Certification.and The contractor duly shall submit the Manufacturer'S Design and drawings of LT panels before placing the order.
The scope of work also comprising of the following:- BUS BAR CHAMBER :- (a) 400 Amp 4 Strips, Aluminium conductor, with color coded(R,Y,B,N) heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings. INSTRUMENT CHAMBER :- (i) Digital Multifunction Meter- 01 Set. (ii) R,Y,B,Phase indicating Lights LED type 220V AC- 1 Set. (Set of three). (iii) Protection MCB 6 A SP C Series- 1 Set. (Set of three). (iv) CT 400/5A Set of -03 INCOMING SUPPLY :- (i) MCCB 200 Amps breaking capacity 35 KA, 4 Pole, 50Hz at 415 Volts, Thermal and Magnetic release with adjustable overload. OUTGOING SUPPLY :- (i) MCCB 125 Amps 25 KA, 4 Pole with Fixed thermal & magnetic release 415 volts , 50Hz = 03 Nos. (ii) MCCB 100 Amps 25 KA, 4 Pole with Fixed thermal & magnetic release 415 volts ,50Hz = 01 Nos. (iii) MCCB 63 Amps 25 KA, 4 Pole with Fixed thermal & magnetic release 415 volts , 50Hz = 01 Nos. Note : All MCCB'S shall conform to IS : 13947 (Part 3, 1993) and IEC-60947 (Part 2) with MES Approved List Makes
Supply, installing, testing and commissioning factory made and tested LT Panel Outdoor type(C.P.R.I Approved), platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system conforming to IS : 375 all as specified herein after. Degree of protection shall not be less than 1P-42 as per IS : 2147 shall be dust and vermin proof, and made of 2.00 mm thick Stainless Steel Sheet SS316 grade & suitable frame made out of MS Iron angle frame, front and Back opening type with space for cable entry from back side of the panel, with proper ferrule & cable gland, internal Connections Shall be Aluminium Bus bar only if MCCB rating is 100 Amps and above sizes, Copper wiring with PVC FRLS insulated multistranded copper conductor FRLS cable can be done of adequate size for MCCB rated below or equal 63 Amps complete all as specified and directed.(P-23 Back Side Panel) Note :The panel manufacturer should have Govt. Approved CPRI Certification.and The contractor duly shall submit the Manufacturer'S Design and drawings of LT panels before placing the order.
The scope of work also comprising of the following:- BUS BAR CHAMBER :- (a) 300 Amp 4 Strips, Aluminium conductor, with color coded(R,Y,B,N) heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings. INSTRUMENT CHAMBER :- (i) Digital Multifunction Meter- 01 Set. (ii) R,Y,B,Phase indicating Lights LED type 220V AC- 1 Set. (Set of three). (iii) Protection MCB 6 A SP C Series- 1 Set. (Set of three). (iv) CT 300/5A Set of -03 INCOMING SUPPLY :- (i) MCCB 160 Amps breaking capacity 25 KA, 4 Pole, 50Hz at 415 Volts, Thermal and Magnetic release with adjustable overload. OUTGOING SUPPLY :- (i) MCCB 100 Amps 25 KA, 4 Pole with Fixed thermal & magnetic release 415 volts , 50Hz = 02 Nos. (ii) MCCB 63 Amps 25 KA, 4 Pole with Fixed thermal & magnetic release 415 volts , 50Hz = 02 Nos. Note : All MCCB'S shall conform to IS : 13947 (Part 3, 1993) and IEC-60947 (Part 2) with MES Approved List Makes
Supply, installing, testing and commissioning factory made and tested LT Panel Outdoor type(C.P.R.I Approved), platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system conforming to IS : 375 all as specified herein after. Degree of protection shall not be less than 1P-42 as per IS : 2147 shall be dust and vermin proof, and made of 2.00 mm thick Stainless Steel Sheet SS316 grade & suitable frame made out of MS Iron angle frame, front and Back opening type with space for cable entry from back side of the panel, with proper ferrule & cable gland, internal Connections Shall be Aluminium Bus bar only if MCCB rating is 100 Amps and above sizes, Copper wiring with PVC FRLS insulated multistranded copper conductor FRLS cable can be done of adequate size for MCCB rated below or equal 63 Amps complete all as specified and directed.(P-24 Back Side Corner Panel) Note :The panel manufacturer should have Govt. Approved CPRI Certification.and The contractor duly shall submit the Manufacturer'S Design and drawings of LT panels before placing the order.
The scope of work also comprising of the following:- BUS BAR CHAMBER :- (a) 400 Amp 4 Strips, Aluminium conductor, with color coded(R,Y,B,N) heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings. INSTRUMENT CHAMBER :- (i) Digital Multifunction Meter- 01 Set. (ii) R,Y,B,Phase indicating Lights LED type 220V AC- 1 Set. (Set of three). (iii) Protection MCB 6 A SP C Series- 1 Set. (Set of three). (iv) CT 400/5A Set of -03 INCOMING SUPPLY :- (i) MCCB 200 Amps breaking capacity 35 KA, 4 Pole, 50Hz at 415 Volts, Thermal and Magnetic release with adjustable overload. OUTGOING SUPPLY :- (i) MCCB 100 Amps 25 KA, 4 Pole with Fixed thermal & magnetic release 415 volts ,50Hz = 01 Nos. (ii) MCCB 63 Amps 25 KA, 4 Pole with Fixed thermal & magnetic release 415 volts , 50Hz = 05 Nos. Note : All MCCB'S shall conform to IS : 13947 (Part 3, 1993) and IEC-60947 (Part 2) with MES Approved List Makes
Material and labour for earthing complete with GI earth plate electrode 600x600x6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground lavel) with top edge of the plate not less than 1.5mtr below normal ground lavel connected to GI Earth strip 32x6 mm by mean of bolts, nuts, check nuts and washer of brash all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including PCC pit and CI cover fullel with watering pipe, wire mess and copper lugs etc GI protection pipe 40 mm dia medium grade including testing on completion all as specified and directed.
Supply Installation Testing and commsissioning of commercial Heat pump water heater(HPWH) of water circulating type system working with input electric power single phase A.C supply 230 Volts,50 Hz , Average Electrical input power between 2.75-3.0 KW at 25° C and produces average Electrical Heating output 12.0 KW Hot water Output 258 Ltrs/Hr at 40-55 ° C Temperature for generate hot water along with Smart Digital Display Controller,Control remote for each pump with Required length of control cable run from Heat pump machine to Smart digital controllers as specified and directed by the Engineer-in-Charge.The warrenty period shall be minimum of 02 Years on heat pump water heater. Make : Jaquar Model No. 12kWHPHS Product No - BFD BCL 120295N,of or Any other equivalent specifications of Racold/A.O.Smith as approved by the GE.
Supply and install 1500 Ltrs storage capacity made with Stainless steel SS304 tank pressurized(Jindal/Tata or any Superior make of SS 304 as approved by the G.E) with Insulation material and Stand. Complete Internal system Piping between tank to Heat Pump, Necessary safety pressure relief valve,Immersion sssesor pockets,Dial type Thermometers ,brass valves,NRV'S Valves and Accessories required for the system Installation with MES approved makes only including Supporting accessiories. complete all as specified and directed. Note : The Installation of the Heat pump water heater and Storage tank should be as per Company Manual Instructions With Company's authorised service person only.The warrenty period shall be minimum of 02 Years on Storage Tank.
Supply,Install,Testing & Commissioning of single phase 230 V 0.75-1 H.P Capacity self priming water Pump with SS Pressure Regulating Valve of 25 mm size(0.5 bar to 5 bar range control) Connected to delivery pipeline with DOL Starter Control direct connected to Heat pump complete all as specified and directed. Make : Kirloskar/Crompton
Supply and Fix Rotational moulded polyethylene water storage tank Capacity 2000 Ltrs (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed. Note : The Rate quoted by the Contractor Shall also Provide Staging base made Up of C section Iron Channel with required size of angular channel or by brick work as directed by the Engr-in-Charge, for placing PVC Tank Upto 2.0 Mtr Height from the Roof of the Building No any extra amount will be paid for provisioning Staging base
Supplying and laying of 32 mm Dia CPVC pipes SDR 11 withstand temperature rating upto 83°C & Plain CPVC SDR fittings on walls/ceiling or laying in floors complete all as specified and directed
Supplying and laying of 20 mm Dia CPVC pipes SDR 11 withstand temperature rating upto 83°C & Plain CPVC SDR fittings on walls/ceiling or laying in floors complete all as specified and directed.
Supply & Fix Chrome plated(CP) 3 Bib taps fancy type cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed Taps on each floor Bathroom for the bore 20mm complete all as specified and directed.
M&L for sub main wiring complete two run of size 4.0 sqmm PVC insulated ,unsheathed, heavy duty 1100 volts grade (FRLS) multi-stranded copper conductor cable,drawn in only PVC casing caping fixed on the surfaces of RCC slab/ceiling/columns/beams etc with all accessories, fittings, PVC junction boxes etc, also including one run of 4.0 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts multi-stranded copper conductor green colour as continous earth wire connected to common earth dolly and mains, complete all as specified and directed. Note: Three run 4 Sqmm PVC cable and one run of Casing Caping will be measured as "one unit"length.
M&L for sub main wiring complete two run of size 6.0 sqmm PVC insulated ,unsheathed, heavy duty 1100 volts grade (FRLS) multi-stranded copper conductor cable,drawn in only PVC casing caping fixed on the surfaces of RCC slab/ceiling/columns/beams etc with all accessories, fittings, PVC junction boxes etc, also including one run of 6.0 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts multi-stranded copper conductor green colour as continous earth wire connected to common earth dolly and mains, complete all as specified and directed. Note: Three run 6 sqmm PVC cable and one run of Casing Caping will be measured as "one unit" length.
Supply and fix sheet metal enclosure powder coated for MCB DB SPN 8 way double door with din rail and 200 A rated bus bar including making good to the disturbed surface matcing with the existing complete all as specified and directed.
Supply and fix MCB SPN 240 volts 63 Amps with breaking capacity 10 KA 'C' Series rating complete all as specified and directed.
Supply and fix MCB SP 240 volts 6-32 Amps with breaking capacity 10 KA 'C' Series rating complete all as specified and directed.
Material and labour for earthing complete with GI earth plate electrode 600x600x6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground lavel) with top edge of the plate not less than 1.5mtr below normal ground lavel connected to GI galvanised iron strip size 25 x 4 mm by mean of bolts, nuts, check nuts and washer of brash all as shown in electrical plate No 4 connected to earthing test point all as specified or indicated including PCC pit and CI cover fullel with watering pipe, wire mess and copper lugs etc GI protection pipe 40 mm dia medium grade including testing on completion all as specified and directed.
S & F Earth continuity conductor GI Galvanised iron strip size 25 x 4 mm or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. complete all as specified and directed.
Material and labour for point wiring complete with 2.5 sqmm PVC insulated unsheathed 1100 volts grade FRLS cable stranded copper conductor single core in PVC casing caping of 20/25 mm complete with sunk iron pressed steel terminal box for fitting mounting switch/sockets regulators etc with laminated sheet 3 mm thick cover and with 2.5 sqmm PVC insulated copper conductor earth wire and connected to earth dolly for power point controlled by one switch complete all as specified and directed.
M&L for sub main wiring complete two run of size 2.5 sqmm PVC insulated ,unsheathed, heavy duty 1100 volts grade (FRLS) multi-stranded copper conductor cable,drawn in only PVC casing caping fixed on the surfaces of RCC slab/ceiling/columns/beams etc with all accessories, fittings, PVC junction boxes etc, also including one run of 2.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts multi-stranded copper conductor green colour as continous earth wire connected to common earth dolly and mains, complete all as specified and directed.(For Storage Geysers) Note: Three run 2.5 Sqmm PVC cable and one run of Casing Caping will be measured as "one unit"length.
Supply & fixing switch modular type 16 Amp single pole one way 230V complete all as specified and directed.
Supply & fixing Socket modular type 16Amp 2/3 pin single pole one way 230V complete all as specified and directed.
Supply & fixing Modular white cover plate with frame 3 Module complete all as specified and directed.
Supply & fixing Modular PVC Surface Box 3 Module complete all as specified and directed.
Supply and laying in trenches/fixing to wall/ ceiling or floor, jointing, GI tubing, medium grade including all fittings such as bends, elbows, tees, union, short pieces, connectors, check nuts, caps, plugs etc complete all as specified and directed for 15 mm dia bore of pipes complete all as specified and directed.
Supply and fixing stop valve 15 mm bore cast copper alloy, screwed down, high pressure with crutch or butterfly handle fancy typ chromium plated, with long shark and cup(concealed type), screwed both ends for iron pipe or for unions and fixed as specified and directed
Supply and fixing bib taps, cast copper alloy with crutch or butterfly handle fancy type chromium plated, screwed for iron pipe fixed as complete all as specified and directed.
Supply and fix electric water heater,storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, inlet and outlet SS Metal conenction Pipes not Less than 0.5 mtr length with Brass nuts etc complete all as specified and directed.
Supply and fix electric water heater,storage type steel body with copper inner tank and heating element upto 2 KW capacity 50 litres Storage capacity, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, inlet and outlet SS Metal conenction Pipes not Less than 0.5 mtr length with Brass nuts etc complete all as specified and directed.
Supply and fix sheet metal enclosure powder coated for MCB DB SPN 8 way double door with din rail and 200 A rated bus bar including making good to the disurbed surface matcing with the existing complete all as specified and directed.
Deduct Credit for Demolished/ Dismantled material Rs. (-) 40000.00 (Minus) as listed in Schedule of Credit Note1: Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum' Note 2:- The tenderer must keep in mind when quoting rates against items out in multiple store house having height 4 mts to 7 mts. Necessary scaffolding and saftey measures required during execution of work are including in this items.
Radha Engineering Services
M/s Mukesh Engineers
somnath engineering corporation
DHARMESH ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .