Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.5 LAccepted-AOC | ₹16.5 L Quoted ₹17.4 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹20.4 L+₹3.0 L (17.2%)Rejected-Finance FLAT NO 201 GREEN VALLEY CHS PLOT NO 26 SECTOR 19 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | ₹20.4 L+₹3.0 L (17.2%) | L2 | Rejected-Finance Being not L1 |
| 3 | L3₹21.9 L+₹4.5 L (25.9%)Rejected-Finance 702 A1 SHREE PRASAD TAWADEWADI SHREE DATTAGURU PARK KUMBHARWADA URAN DIST RAIGAD MAHARASHTRA 400 702 | URAN | RAIGAD | MAHARASHTRA | 400702 | ₹21.9 L+₹4.5 L (25.9%) | L3 | Rejected-Finance Being not L1 |
| 4 | L4₹24.9 L+₹7.5 L (43.4%)Rejected-Finance | ₹24.9 L+₹7.5 L (43.4%) | L4 | Rejected-Finance Being not L1 |
| 5 | L5₹25.0 L+₹7.6 L (43.6%)Rejected-Finance 1501 BHAGWATI EMINENCE SAVITRIBAI PHULE MARG BESIDES R R PATIL GARDEN SECTION 13 NERUL E NAVI MUMBAI | RAIGAD | MAHARASHTRA | 400702 | ₹25.0 L+₹7.6 L (43.6%) | L5 | Rejected-Finance Being not L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
6 Dec 2019, 6:00 pmClosed
GE NW KARANJA
NAVAL STATION KARANJA, URAN, RAIGAD, MAHARASHTRA
REP REPLACEMENT MAINT OF LT SWITCH GEAR CAPACITOR BANK APFC PANEL SERVO VOLTAGE STABILIZER AND IMPROVMENTS OF SUB STATION INCL REPLACEMENT OF EARTHING CABLE DUCT COVER PAINTING REP OF PANELS REPLACEMENT OF GLOW SIGNS BOARD AND OTHER CONNECTED AT N S
2019_MES_296437_1
8209/05/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE NW KARANJA
REP REPLACEMENT MAINT OF LT SWITCH GEAR CAPACITOR BANK APFC PANEL SERVO VOLTAGE STABILIZER AND IMPROVMENTS OF SUB STATION INCL REPLACEMENT OF EARTHING CABLE DUCT COVER PAINTING REP OF PANELS REPLACEMENT OF GLOW SIGNS BOARD AND OTHER CONNECTED AT N S
8 documents required · 8 mandatory
₹500
Yes
GE NW KARANJA
₹60,000
Yes
15 Jan 2020
9 Nov 2019
7 Dec 2019
9 Nov 2019
6 Dec 2019
23 Nov 2019
9 Nov 2019 - 23 Nov 2019
Amount
Taking down carefully copper/aluminium point wiring ( light, fan socket or powder) complete, including fixtures fitting such as switches, ceiling roses , pendants regulators socket etc. removing material to store for keeping in safe custody or for taking credit (Credit for above items should be made as per conditions separately) and making good disturbed surfaces walls, floors etc. all as specified and directed.
M&L for point wiring in steel conduit 20 mm dia or more confirming to IS 2079-1973 medium grade in consealed with PVC insulated unsheathed multistranded copper conductor cable( FRLS) 1.5 sqmm nominal cross sectional area 1100 volts grade complete with all fittings such as Elbow, bends, junction boxes, saddles incl sunk 20mm dia medium grade steel conduit (2mm wall thickness minimum as per IS-9537) (ISI marked) pressed steel not less than 2 mm thick, 50 mm deep terminal boxes with 3mm thick ISI marked minimum width 25 mm, white/creamy colour, plastic laminated sheet top cover fastended with chromium plated brass screws including 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts Multistranded copper conductor green colour as continuous earth wire connected to common earth dolly all as specified and directed for the following:-
a) One light point/fan point/ exhaust fan point controlled by one 5 Amp switch
b) One multi pin socket outlet 5 Amps independent complete
As per sl item No 2 here -in- before but with 4 sqmm cable for one 3 pin socket outlet 15 Amps multipurpose independent in & including 1.5 sqmm PVC insulated unsheathed multistranded copper earth continuity wire connected from common earth point complete all as specified and directed.
S&F switch piano flush button single pole one way, 5 Amp ( ISI marked), complete all as specified and directed.
S & F switch socket outlet 2 in 1, 3 pin 6 Amp (ISI marked) , complete all as specified and directed. .
S&F switch socket outlet multi purpose 5-in-1, 15 Amp controlled by one switch (ISI marked), complete all as specified and directed.
S&F ceiling rose surface bakelite 65 x 50mm, three terminals ISI marked, all as specified and directed.
S&F step type electronic regulator flush type on the existing phenolic laminated sheet complete all as specified and directed.
S&F LED Tube light fitting 1x18 watt with LED tube fixed on wall and conection with ceiling rose complete all as specified an directed. Make/Model : Bajaj/BLRB-DB/BLRB 18 W CW or equivalent of Philips/Wipro.
S & F SPN 8 way vertical type DB double door 240 Volts
S & F SPN 4 way vertical type DB double door 240 Volts
S & F SPN 2 way vertical type DB double door 240 Volts
S & F SP MCB 240 V 50 Hz 10 KA confirming to IS 8828 of rating 6 to 32 Amp as per Cat No. Cat No. DHMCCSPF006-032 of Havells or equivalent of Legrand/schneider all as specified and directed.
S&F MCB DP, 240V, 50Hz, 10 KA , conforming to IS 8828 of rating 32 Amp Make Havells or equivalent of of M/s Legrand/Schneider/Siemens as in repairs, all as specified and directed.
Supply and fixing LED building security light fitting with suitable size bracket/angle to fit security light of 60w IP 66 protection LED make bajaj ct pt no-169680 of EDGE Series or equivalent in havells/c&s
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr depth and getting out in any type of soil including taking out faulty cable / cable / cable covers and GI pipe complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and depth exceeding 1.5mtr but not exceeding 3.0 mtr and getting out in any type of soil including taking out faulty cable / cable /cable covers and GI pipe complete all as specified and directed.
Removing excavated materials to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point.
M & L for PCC type C2, 1:3:6 using (40 mm graded stone aggregate) in foundations of poles / struts includings necessary form work complete all as specified & directed
M & L for PCC type B-1, 1:2:4 using (20 mm graded stone aggregate) for pole / strut coping, including form work complete all as specified & directed
Supply and installation of steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts, and screws as specified type confirming to IS 2713 complete including 2 coats of aluminium paint over one coat of red oxide primer on external exposed surfaces and 2 coats of black bituminous paint on portion embedded in concrete complete all as specified and directed for the following:- NOTE :- Excavation and earth work and PCC foundation and plinth will be measured and paid separately under respective items of Sch ‘A’
(a) 410 SP-31 (9 mtr long)
(b) 410 SP -22 (8.5 mtr long)
M&L Danger notice plate of 1.6 mm thick mild steel sheet,vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S Clamps, bolts and nuts of size 20 x 15 cm.
Earthing complete with GI earth plate electrode 60cm x 60 cm x 6 mm buried directly in ground vertically to a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level connected to and including GI strip 32 x 6 mm by means of bolts, nuts and check nuts and washers etc made of GI & connected to Earthing test point and earth dolly all as shown in elect plate No 5 of SSR Pt-I incl all necessary earth work, excavation, PCC chamber, chamber cover with handle (PCC 1:2:4) including 15 mm dia protection pipe & 20 mm dia watering pipe and wire mesh funnel etc all as specified and as directed by Engr-in-charge.
M & L for preparing old surfaces of exposed surfaces of LT street light steel tubular poles 8.5/9.0 mtr long & Painting exposed surfaces with one coat of aluminium paints, including numbering etc all as specified and directed by Engineer-in-Charge
S & F MCCB -DPX3 160 thermal & magnetic type 4 pole 415 volt 25 kA breaking cap. adjustable thermal release range 100 Amps to 125 Amp Cat ref no. 4200 55 of make Legrand or equivalent in M/s Schenider/M/s L&T in replacement/ repairs complete all as specified and directed.
S & F MCCB -DPX3 250 thermal & magnetic type 4 pole 415 volt 25 kA breaking cap. adjustable thermal release range 200 Amps Cat ref no. 4202 18 of make Legrand or equivalent in M/s Schenider/M/s L&T in replacement/ repairs complete all as specified and directed.
S & F MCCB -DPX3 250 thermal & magnetic type 4 pole 415 volt 36 kA breaking cap. adjustable thermal release range 250 Amps Cat ref no. 4202 49 of make Legrand or equivalent in M/s Schenider/M/s L&T in replacement/ repairs complete all as specified and directed.
S & F MCCB -DPX3 630 thermal & magnetic type 4 pole 415 volt 36 kA breaking cap. adjustable thermal release range 400 Amps Cat ref no. 4220 07 of make Legrand or equivalent in M/s Schenider/M/s L&T in replacement/ repairs complete all as specified and directed.
S & F On load change over switch as sheet steel enclosure 63 A, 415V,AC 23 A,4P & Type CO3-63 Cat Ref No CO6300OSOO of M/s L & T or equivalent in M/s Havells/ M/s Schneider as in replacement/ repairs complete all as specified and directed
S & F On load change over switch Manual as open Execution 250 A, 415V,AC 23 A,4P & Type CO3-250 Cat Ref No CO32500OSOO of M/s L & T or equivalent in M/s Havells/ M/s Schneider as in replacement/ repairs complete all as specified and directed
S & F On load change over switch Manual as open Execution 400 A, 415V,AC 23 A,4P & Type CO4-400 Cat Ref No CO4400OSOO of M/s L & T or equivalent in M/s Havells/ M/s Schneider as in replacement/ repairs complete all as specified and directed
Supply and fix in repairs 1.1 KV straight through joint kit 3.5 core 25 sq mm to 50 sqmm of make 3M/M Seal/ Raychem.
Supply and fix in repairs 1.1 KV straight through joint kit 3.5 core 70 sqmm to 120 sq mm of make 3M/M Seal/ Raychem.
Supply and fix in repairs 1.1 KV straight through joint kit 3.5 core 150 sq mm to 185 sqmm of make 3M/M Seal/ Raychem.
Supply and fix in repairs 1.1 KV straight through joint kit 3.5 core 240 sq mm to 300 sqmm of make 3M/M Seal/ Raychem.
Supply and fix in repairs 1.1 KV straight through joint kit 3.5 core 400 sq mm of make 3M/M Seal/ Raychem.
Supplying, fixing, jointing, connecting & testing in trenches XLPE/PVC insulated PVC sheathed cable heavy duty 1100 volts grade, aluminum conductor in trenches / ducts /on wall surface as in repairs of following sizes all as specified and directed.
(a) 2 core 10 Sqmm
(b) 2 core 16 Sqmm
(c) 4 core 16 Sqmm
(d) 3.5 core 25 Sqmm
Returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm complete all as specified & directed.
M & L for dry river sand as sand cushioning for protection of UG cable including punning of sand in layers all as specified.
Supply & laying un-reinforced precast concret cable cover class LV type 1, flat size 250mm x 150mm x 40 mm all as specified & directed.
M & L for MS plate plain or chequerred squre cut or notched forming holes with or without any attatchment including welding etc all as specified and directed.
M & L for PCC type C2, 1:3:6 using (40 mm graded stone aggregate) in foundations ,filling and mass concrete includings necessary form work complete all as specified & directed
Supply and filling in layers n.exc 25cm thick with 40mm graded coarse aggregates in structures complete all as specified and directed.
Supplying, installing, testing and commissioning of factory made LT cubical double door panel with roof canopy ,INDOOR TYPE, suitable size made out of CRCA sheet 2 MM thick duly powder coated with Seimens Grey Shade RAL 7032, totally enclosed, dust and vermin proof outer cubicle. Inner cubicle should be made out of 2 MM thick CRCA sheet with working voltage of 415V, 50 Hz, 3 phase 4 wire fully compartmentalised with single door system for each compartment. Outer cubicle having both sides door openable and Bus bars provided shall be adequately supported on insulators to withstand dynamic stresses due to short circuit current and shall be suitably colour coded with heat shrinkable sleeve for phase indication. The standard phase arrangement when facing the switchgear shall be R-Y-B from left to right. The bus bar connections and their insulated supports shall be mechanically strong, and shall withstand all the stresses which shall be imposed upon them in ordinary working due to fixing, vibration, fluctuation in temp., shot-circuit or other causes. The bus bar should be supported on DMC. Provision shall be made for expansion and contraction of the bus bars and connections with variation of temp. Internal wiring should be done with 2.5 sqmm multi-stranded copper conductors and shall be properly bunched, tied, ferruled for proper identification, crimped and shall be connected with suitable lugs and PVC sleeves, etc. The bottom of the panel should contain detachable plate having provision for entry of armoured cable of adequate size with glands. Threaded earthing studs - 02 Nos shall be provided at the bottom and lifting lugs of suitable size at top to lift the panel safely shall be made. The cubicle incomer MCCB as well as outgoings shall have copper TPN/TP extension links of current rating not less than 1.5 times the rated capacity of individual feeders with Ics = 100% Icu in all MCCBs with extended Rotary Handle. The cubicle should be inclusive of following : The cubicle should be inclusive of following :
Location:- NAD Main PUMP House (A) INCOMING - (a) Air Circuit breaker with micropressor release 4 pole, 800 Amps, 50 kA, manual Drawn out type. Make Legrand Cat Part No. 028731 + 028802 with O/L, S/C & E/F protections or equivelent in Siemens/ABB/L&T - 01 No (b) On-load Changeover Switch I-O-II open execution, 4 pole - 800 Amps, L&T Make Cat No CO58000OOOO or equivalent in Havells/ABB/Siemens/Legrand - 01 No (B) OUTGOING - (a) MCCB -DPX3 630 thermal & magnetic type 4 pole 415 volt 36 kA breaking cap. adjustable thermal release range 630 Amps Cat ref no. 4220 09 of make Legrand or equivalent in M/s Schenider/M/s L&T – 01 No. (b) MCCB -DPX3 630 thermal & magnetic type 4 pole 415 volt 36 kA breaking cap. adjustable thermal release range 400 Amps Cat ref no. 4220 07 of make Legrand or equivalent in M/s Schenider/M/sSiemens – 02 No. (c ) MCCB -DPX3 160 thermal & magnetic type 4 pole 415 volt 25 kA breaking cap. adjustable thermal release range 250Amps Cat ref no. 4202 19 of make Legrand or equivalent in M/s Schenider/M/sSiemens – 02 No. (d) MCCB -DPX3 160 thermal & magnetic type 4 pole 415 volt 25 kA breaking cap. adjustable thermal release range 100 Amps Cat ref no. 4200 55 of make Legrand or equivalent in M/s Schenider/M/sSiemens – 02 No. (e) Multi function meter having LCD Display,96 x 96 sq.mm -01 No
M&L Glow sine board 3mm Acrylic shut and 1.25 inch molded LED letter for writting of " GARRISON ENGINEER (NW) KRANJA 22 KV ELECTRIC SUB STATION - MRF " with one side MES logo and another side Div sign on board complete with support frame of 3mm aluminium composite panel with 1" x 1.5" alumnium pipe complete with fixing on wall surface by using of MS clamp Nut, bolt ,anchor fastioner etc complete all as specified and directed
M&L Glow sine board 3mm Acrylic shut and 1.25 inch molded LED letter for writting of " GARRISON ENGINEER (NW) KRANJA 22 KV ELECTRIC SUB STATION - J" with one side MES logo and another side Div sign on board complete with support frame of 3mm aluminium composite panel with 1" x 1.5" alumnium pipe complete with fixing on wall surface by using of MS clamp Nut, bolt ,anchor fastioner etc complete all as specified and directed
M&L Glow sine board 3mm Acrylic shut and 1.25 inch molded LED letter for writting of " GARRISON ENGINEER (NW) KRANJA 22 KV ELECTRIC SUB STATION - FODC " with one side MES logo and another side Div sign on board complete with support frame of 3mm aluminium composite panel with 1" x 1.5" alumnium pipe complete with fixing on wall surface by using of MS clamp Nut, bolt ,anchor fastioner etc complete all as specified and directed
Painting to electric control panel/APFC Panel/LT Panel/Feeder Piller box /Bus bar panel any type and any size of E/M installations by cleaning the existing old paint with the help of mechanical tools such as wire brush, scraper and sand paper from the surface of panel and painting the prepared surface with two coat of synthatic enamel paint of approved shade over a coat of red oxide primer complete all as specified and specified.
S & F in repairs Pressure die cast aluminium housing LED street light luminaires with IP66 ,EDGE Series,72 Watt & accessories and connecting up to looping box with PVC insulated multi stranded copper conductor cable 1.5 sqmm twin Core all as specified and directed. Make : Bajaj Cat ref No BRTFG 72 W LED I or equivalent in M/S Surya /Philips.
As per item No 49 above but Cat ref No BRTFG 90 W LED I of M/S Bajaj or equivalent in Crompton / Philips.
As per item No 49 above but Cat ref No BRTFG 120 W LED I of M/S Bajaj or equivalent in Crompton / Philips.
M&L GI pipe light grade with all fittings complete laid in trenches all as specified for 40 mm bore of pipe complete all as specified and directed
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed
M&L 15mm thick cement plaster (1:6) on fair faces of brick work or concrete surfaces complete all as specified and directed
Applying three coats of white wash on new wall surface including preparation of surface complete all as specified and directed
M&L for cleaning of sub-station Bldg from inside and outside by brooming /scrasing of wall/floor /roof and taking out LT cables from duct after disconnecting from LT panel and relaying of cable with properly dressed, refixing the duct cover and reconnecting the cable to LT panel complete as dircted with area cleaning of sub stn by cutting of tree, bushes, roots, crepers and taking out the bubrais from the sub-staion boundaries and deposited within a distance of 1 KM radious complete all as specified and directed by Engineer-in-Charge.
S&F automatic power factor control relay of 8 stage supply Voltage - 230 V AC and current Input - 1A or 5 A,Steps- 8 relay outputs ,Supply Voltage - 1Ph 230 VAC (-20% to +10% ),Measurement Voltage : 1Ph 2 wire 230 VAC (-20% to +10% ) ,Operating temperature : 0 to 70 º C , COMPACT 96 X 96 MM Front fascia of M/S EPCOS CAT NO.BR4000,PFC CONTROLLER-BR-4000-08 ST-RELAY 230V Material Code - B44066R4808A230N 1 or equivalent in Schnieder/ABB/Syntron including testing, connecting, commissioning in such a way to avoid "controller hunting" complete as in repairs as specified and as directed having following features - a) Microcontrller logic for measurement b) User frindly operation c) Control mode : binary , unequal and user defined d) Multifunctional LCD display e) Single CT sensing for balanced loads f) Individual harmonic measurement upto 15th order
S&F automatic power factor controller of 12 stage supply Voltage - 230 V AC and current Input - 1A or 5 A,Steps- 12 relay outputs ,Supply Voltage - 1Ph 230 VAC,Measurement Voltage : 1Ph 30V-525V AC (L-N) or (L-L),Operating temperature : 20 to 60 º C , of M/S EPCOS CAT NO.BR6000,PFC CONTROLLER-BR-6000-12 STP-RELAY 230V Material Code - B44066R6012R230N 1 or equivalent in Schnieder /ABB /Syntron including testing, connecting, commissioning in such a way to avoid "controller hunting" complete as in repairs as specified and as directed having following features - a) Microcontrller logic for measurement b) Self explanatory menu navigation in several languages c) Self optimizing control capability d) Control modes: LIFO, FIFO and Self optimized Intelligent Control. e) Large and multifunctional LCD with backlit display (2 X 16 characters) f) Single CT sensing for balanced loads g) Dual target Power Factor setting (available in 12 stage) - useful for utility and DG mode operation available optional h) Automatic synchronization possible j) Display and storage of maximum values, number of switching operations and operating time k) Recall function of recorded values l) RS232 Interface optional m) Alarm output optional n) Dynamic Power Factor Controller (Transistorised) available in 6 and 12 steps
o) Cascading possible with master slave versions p) Protective earth terminal to reduce noise and unwanted interference signals q) EMI/ EMC type tested r) Individual Harmonic measurement th upto 19 order.
S&F Capacitor square cap EHDLL - 440 V (AC) , 3phase, 50 Hz, of capacity 2 kVAr of M/s EPCOS CAT No.-B32459L5002A 11 or equivalent in M/s L&T / M/s Schnieder / M/s ABB / M/s Siemens including testing, commisioning as in repairs complete all as specified and directed.
S&F Capacitor same as Item No. 14 but of capacity 5 kVAr of M/s EPCOS CAT No.-B32459L5005A 11 or equivalent in M/s L&T / M/s Schnieder / M/s ABB / M/s Siemens including testing, commisioning as in repairs complete all as specified and directed.
S&F Capacitor same as Item No. 14 but of capacity 10 kVAr of M/s EPCOS CAT No.-B32459L5010A 11 or equivalent in M/s L&T / M/s Schnieder / M/s ABB / M/s Siemens including testing, commisioning as in repairs complete all as specified and directed.
S&F Capacitor same as Item No. 14 but of capacity 15 kVAr of M/s EPCOS CAT No.-B32459L5015A 11 or equivalent in M/s L&T / M/s Schnieder / M/s ABB / M/s Siemens including testing, commisioning as in repairs complete all as specified and directed.
S&F Capacitor same as Item No. 14 but of capacity 20 kVAr of M/s EPCOS CAT No.-B32459L5020A 11 or equivalent in M/s L&T / M/s Schnieder / M/s ABB / M/s Siemens including testing, commisioning as in repairs complete all as specified and directed.
S&F Capacitor same as Item No. 14 but of capacity 25 kVAr of M/s EPCOS CAT No.-B32459L5025A 11 or equivalent in M/s L&T / M/s Schnieder / M/s ABB / M/s Siemens including testing, commisioning as in repairs complete all as specified and directed.
Supply & fix power capacitor duty contactor 3 phase with auxilary switch block 415 volts suitable for 8.5 kVAR as per Cat No. CS96320 of M/s L & T or equivalent of M/s Siemens/ M/s Schnieder / M/s ABB/ M/s Epcos including testing connecting commissioning complete all as specified and directed.
Supply & fix power capacitor duty contactor 3 phase with auxilary switch block 415 volts suitable for 15 kVAR as per Cat No. CS90019 of M/s L & T or equivalent of M/s Siemens/ M/s Schnieder / M/s ABB/ M/s Epcos including testing connecting commissioning complete all as specified and directed.
Supply & fix power capacitor duty contactor 3 phase with auxilary switch block 415 volts suitable for 30 kVAR as per Cat No. CS96323 of M/s L & T or equivalent of M/s Siemens/ M/s Schnieder / M/s ABB/ M/s Epcos including testing connecting commissioning complete all as specified and directed.
Supply & fix HRC Bolted fuse link,Type HQ,offset, fixing method A2, 32 amps per Cat No. ST30753 with suitable fuse holders for bolted fuse links 32 amp type HK 32 H ,Fuse type A2 as per Cat No. ST30754 of M/s L & T or equivalent of M/s Schneider/ M/s Siemens M/s HPL complete as in repairs all as specified and directed.
Supply & fix HRC Bolted fuse link,Type HQ,offset, fixing method A3, 63 amps per Cat No. ST30761 with suitable fuse holders for bolted fuse links 63 amp type HK 63 H ,Fuse type A3 as per Cat No. ST30762 of M/s L & T or equivalent of M/s Schneider/ M/s Siemens M/s HPL complete as in repairs all as specified and directed.
Supply & fix HRC Bolted fuse link,Type HQ,offset, fixing method F1, 2-20 amps per Cat No. ST30730 with suitable fuse holders for bolted fuse links 2-20 amp type HD 20 H ,Fuse type A3 as per Cat No. ST30772 of M/s L & T or equivalent of M/s Schneider/ M/s Siemens M/s HPL complete as in repairs all as specified and directed.
M&L for control wiring of the panel with 440V 10 Sq mm PVC insulated stranded single core copper conductor cable conforming to IS for power circuit, the wire ends will be ferruled including disconnecting and removing the unserviceable wire complete connecting testing all as specified and directed. Make- Nicco/Plaza/Havells/Finolex
As Srl item No 71 herein before but 6 Sqmm cable.
As Srl item No 71 herein before but 4 Sqmm cable.
As Srl item No 71 herein before but 2.5 Sqmm cable.
S&F Analogue Ammeter in replacement for measuring alternating current of range : 0 - 200 A flush type 96x96MM size all as specified and directed.
S&F Analogue Voltmeter in replacement for measuring alternating current voltage of range : Range 0-500 V flush type 96x96MM size all as specified and directed.
S&F in replacement indoor resin cast ring type current transformer of ratio 200/5 Amps, accuracy - 15VA, Class - 1 all as specified and directed.
M & L for sheet metal work for repair to electric panel doors, bus bar cover and accessories mounting supports for alignment with front door with 2 mm thick MS sheet duly painted with super enameled paint over one coat of red oxide primer including necessary cutting, welding and fixing in repairs complete.
S&F MCB SPN, 10kA, 6-32 AMPS of Legrand Make, CAT NO-4086 09 to 4086 17 all as specified and directed.
S&F MCB TP, 10kA, 40-63 AMPS of Legrand Make, CAT NO-40896 59 to 4086 61 all as specified and directed.
S&F MCB SP, 10kA, 6-32 AMPS of Legrand Make, CAT NO-4085 87 to 4085 95 all as specified and directed.
S&F in replacement Rotary Type A/M Switch, 1 Pole, 2 Way with Off, Make - KAYCEE//L&T/SIEMENS all as specified and directed.
S&F Flush head Push Button Green/Red colour with 1 NC Block, Make - L&T all as specified and directed.
S&F Plastic body Instrument Cooling axial fan of 120 x 120 x 38 mm size fitted complete within the panel including cutting of a suitable sized hole on the panel body and wiring with 1.5 Sqmm copper conductor cable and MCB SPN 6 Amps all complete as per satisfaction of Engr-in-Charge.
S&F in replacement LED indicator - R/Y/B/G 240 V AC.
S & F power contractor 3 pole , type ML-2 with 2 No + 2NC aux contacts with standard coil voltage 240 volts, rating 32 amp asper cat No 90701 of M/s L & T or or equivalent in M/s Schnieder / M/s ABB / M/s Siemens including testing, commisioning as in repairs complete all as specified and directed.
S & F power contractor 3 pole , type ML-3 with 2 No + 2NC aux contacts with standard coil voltage 240 volts, rating 40 amp asper cat No 90721 of M/s L & T or or equivalent in M/s Schnieder / M/s ABB / M/s Siemens including testing, commisioning as in repairs complete all as specified and directed.
S & F power contractor 3 pole , type ML-4 with 2 No + 2NC aux contacts with standard coil voltage 240 volts, rating 70 amp as per cat No 90910 of M/s L & T or or equivalent in M/s Schnieder / M/s ABB / M/s Siemens including testing, commisioning as in repairs complete all as specified and directed.
S & F power contractor 3 pole , type MNX 25, Size fr 2,AC3 rating (25 amp) as per cat No CS94110 of M/s L & T or or equivalent in M/s Schnieder / M/s ABB / M/s Siemens including testing, commisioning as in repairs complete all as specified and directed.
S & F power contractor 3 pole , type MNX 40, Size fr 2,AC3 rating (40 amp) as per cat No CS94190 of M/s L & T or or equivalent in M/s Schnieder / M/s ABB / M/s Siemens including testing, commisioning as in repairs complete all as specified and directed.
S & F power contractor 3 pole , type MNX 50, Size fr 3,AC3 rating (50 amp) as per cat No CS97075 of M/s L & T or or equivalent in M/s Schnieder / M/s ABB / M/s Siemens including testing, commisioning as in repairs complete all as specified and directed.
Disconnecting incoming and outgoing connections, taking out and overhauling of manually operated, draw out type air circuit breaker of any make 3 pole, 415 volts, AC, current rating 800-1600 A, including cleaning/ oiling/ greasing all mechanical moving parts, replacement of defective accessories, racking in and connecting incoming/ outgoing cables complete all as specified and directed. Note : Accessories required for replacement shall be measured & paid separately under respective item of this schedule'A'.
Supply only following accessories suitable for ACB of any make and capacity :-
a)Auxiliary contact
b)motor
c)Trip alarm contact
d)Under voltage release
e)Shunt realease
f)Insulation barrier
g)Earth fault release
h)Racking interlock
Supply and fill in new Tranformer /stablizer oil having 60 KA di-electric strength and conforming to IS-335/1993. Make :- M/S Kirloskar/ M/s Hindustan Petrolium/ Indial Oil/ BP.
M&L for carrying out following work/repairs through manufacturer's authorised service engineer of voltage stabilizer of following capacities located at various tech Accn at Naval Station Karanja :- i) Opening of stabilizer at tech Accn workshop and taking out all defective / unserviceable parts, fixing of new parts after repair inplace of defective part, rewiring of defective control wiring etc and assembling complete all as specified & directed. ii) Testing of stabilizer after repair on existing load to give desired & rated output. iii) M & L for preparation of old painted surface by hand scrap and applying one coat of primer and two coats of synthetic enamel paint by spray painting. Note : - All defective parts including cable & oil to be replaced will be measured & paid separately under relevent item of schedule as supply only. However, cost of labour for fixing of new part is deemed to be included in unit rate of Sl item No.1 above. a) 25 to 75 KVA capacity
b) 100/125 KVA capacity
c) 150 KVA capacity
d) 200 KVA capacity
Supply only under mentioned spares for voltage stabilizer of different capacitites:- a)Synchronising motor low speed instant start, stop high torque input voltage 250V single phase 50HZ, 60 RPM type -of following capacity Make AE/ME/ as per existing make (i). 3 Kg
b)Voltage meter 0-500 Volts flush type square dial 96mm size Make :- AE/ME/as per existing make
d)Control relay AC 230V, 250 OHMS, 1 pin with base plate.AC Make :- AE/ME or equivalent
e)Control relay 250 OHMS, 1 pin with base plate, 12V DC. Make :- AE/ME or equivalent
f)Control relay 230V, 250 OHMS, 1 pin with base plate, 24V DC. Make :- AE/ME or equivalent.
g)Control operational switch 10 Amps capacity. Make : AE/ME/KAYCEE
j)Control transformer/relay 24Volt DC. Make :- AE/ME or equivalent
l)Toggle switch 10Amps. Make :- AE/ME/SIEMENS/BCH
m)Indication lamp with bulb RYB. Make :- L&T/Teknic or equivalent
n)Limit switch with aluminum housing. Make :- AE/ME or equivalent
o)Reset switch 10 Amps 230V AC. Make :- AE/ME/TEKNIC
p)Voltage increase/ decrease switch 10 A cap. Make :- AE/ME/KAYCEE
q)Aluminum hand wheel for manual operation. Make :- AE/ME or equivalent
r)Aluminum brush assembly for 200KVA stabilizer. Make :- AE/ME
s)Aluminum brush assembly for 50/75/100/125/150 KVA stabilizer. Make :- AE/ME or equivalent
t)Terminal strip for 200 KVA stabilizer
u)Terminal strip for 25/50/75/100/125/150 KVA /3x 16.6 KVA stabilizer
v)Variable voltage wound coil single phase. Make:- AE/ME for 200 KVA stabilizer
w)Variable voltage wound coil single phase. Make:- AE/ME for 50/75/100/125/150 KVA /3x 16.6 KVA KVA stabilizer
x)Variable voltage wound coil single phase. Make:- AE/ME for 25 KVA stabilizer
y)Rectifier 15 Amp. Make :- AE/ME/RATANSHAH
z)Insulator for dimmer. Make :- AE/ME
aa)Electrolytic capacitor 150mfd. 220V. Make :- Asian/Rescon or equivalent
ab)Electrolytic capacitor 1200mfd. 440V. Make :- Asian/Siemens or equivalent
ac)Carbon brush. Make :- AE/ME or equivalent
ad)AC motor drive control cord. Make :- AE/ME or equivalent
ae)Control PCB of control circuit of stabilizer 16.6 KVA to 500 KVA voltage stabilizer.
af) as per above but cut off PCB
ag)Control transformer for 16.6 KVA to 500 KVA voltage stabilizer.
ah)as per above but cut off control tranformer
M.K Enterprises
Sagar Electricals
R A Electric Co.
SREE HARITHA ASSOCIATES
somnath engineering corporation
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .