Staff Officer E and M Pench Area Parasia
AGM Office Pench Area Parasia
Diversion of 3.3kV HT line feeding power to Shivpuri OCM and Shivpuri Colony from VP2 UG Mine Substn
2022_WCL_248555_1
wcl-pe3350-enm-023-2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
60 days
Vishnupuri 2 UG Mine Pench Area Parasia
2 documents required · 2 mandatory
₹25,800
4 Jun 2023
30 Jun 2022
19 Jul 2022
30 Jun 2022
18 Jul 2022
30 Jun 2022
30 Jun 2022 - 8 Jul 2022
Amount
Diversion of 3.3kV HT line feeding power to Shivpuri OCM and Shivpuri Colony from VP2 UG Mine Substation.
Dismantling of existing steel pole, R.S. Joist, girder with bracket clamp insulator or stay from the cement concrete foundation and making the site clear by refilling the pit to ground level i/c transportation to required destination within township.
Dismantling of existing overhead ACSR, AAAC, GI, conductor and making the site clear i/c transportation to required destination within township
RS Joist/H-Beam: Supply of R.S. Joist (25.4 kg/metre and 11 mtr height each) including drilling of hole, other work as required.
ACSR conductor: Supplying and drawing of stranded aluminium conductor steel reinforced (ACSR) conforming to IS:398-1976 of approved make, stringing, making off complete with binding at existing insulator, jointing, jumpering, tearing off, connecting etc. as required and clearing of obstacles (if any) etc. Dog: ACSR 0.1 sq inch (100 sq.mm Al. EQ.)- (Dog)
Erection of poles, length exceeding 10 metres but not exceeding 13 metres; Erection of RS Joist pole/'H' beam/steel tubular/steel rail pole of length exceeding 10 metres but not exceeding 13 metres in cement concrete M-10 (1 cement:3 core sand: 6 graded stone aggregate 40mm nominal size) base, foundation, muffing including excavation and back refilling etc. as required
Stay set complete (galvanized) with 16mm dia x1.8 metre long stay; Supplying and erection of stay set complete (galvanized) with 16mm dia x1.8 metre long stay anchor plate of size 200mm x 200mm x 6.0mm thimble stay clamp turn buckle 19mmx600mm, 7/3.15mm dia G.I. stay wire etc. in cement concrete M-10 (1 cement: 3 coarse and: 6 grinded stone aggregate 40mm nominal size) foundation including excavation and refilling etc. as required.
11 KV porcelain pin insulator: Supplying and erection of 11KV porcelain pin insulator complete with long steel head G.I. pin, nut, washer etc. as required
Set of three 11KV porcelain disc insulators for 33KV overhead lines; Supplying and erection of a set of three 11KV porcelain disc insulators for 33KV overhead lines with galvanized insulator fittings, ball and socket type, and complete with galvanized strain clamp, bolts, nuts, washers etc. as required.
Labour, 11/33KV porcelain pin insulator; Labour for erection of 11/33KV porcelain pin insulator complete with hardware as required.
Labour, 11KV porcelain disc insulators for 33KV overhead lines; Labour for erection of a set of three/ four 11KV porcelain disc insulators for 33KV overhead lines complete with hardware as required.
Single piece nonlinear resistor type lightning arrestor (set of 3 nos) for 3 wire, 11 KV; Supplying and erection of single piece nonlinear resistor type lightning arrestor (set of 3 nos) for 3 wire, 33KV overhead lines/sub-station with rated voltage of 9 KV (rms) with a nominal discharge current rating of 10 KA and complete with galvanized clamping arrangement, G.I. bolts, nuts, washer etc. as required.
Outdoor H.T., AB switch assembly set; Supplying installing, testing & commissioning of outdoor H.T., AB switch assembly set gang operated with brass contact parts, including required GI pipe operating rod, handle & locking arrangement on On-Off position conforming to IS complete with required material and installing on existing DP structure to complete the job as required as per specification.(Set of 3 nos.); 11 KV, 400Amp
D.O. fuse; Supplying installing, testing & commissioning D.O. fuse assembly with brass part contact for 33 or 11/0.4 KV DP Structure set of 3 Nos. with fuse barrel i/c required fuse element & other materials as per specification on existing D.P. structure as required., 11 KV
Angle/channel/flat iron fitting for overhead line & substation etc.; Supply, fabrication and erection of angle/channel/flat iron fitting for overhead line & sub-station etc such as 'D' bracket, cross arms, top clamp, 'V' cross arms, back/support clamp or other similar work etc. including nut bolts of required size, making holes, fabrication, welding, cutting, etc. and painting with one coat of red oxide paint & two coat of aluminium paint as required as per specification.
Labour charges for erection of angle/channel/flat iron fitting for overhead line & substation etc; Labour charges for erection of angle/channel/flat iron fitting for overhead line & sub-station etc such as 'D' bracket, cross arms, top clamp, 'V' cross arms, back/support clamp or other similar work etc. including nut bolts of required size, as required as per specification
GST as applicable should be quoted in percentage, it will be calculated on total amount of Sl. No. 1.01 to 1.16
RAJ ENGINEERING ASSOCIATE
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .