Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.8 LAccepted-AOC | ₹18.8 L Quoted ₹19.1 L | L1 | Accepted-AOC Being L1 bidder |
| 2 | L2₹19.9 L+₹84,189.40 (4.41%)Rejected-Finance | ₹19.9 L+₹84,189.40 (4.41%) | L2 | Rejected-Finance Being other than lowest bidder |
Tender Value
₹23 L
EMD Value
₹46,000
Closing Date
28 Nov 2022, 6:00 pmClosed
GE 865 EWS
GE 865 EWS, PIN-913 865 C/o 56 APO
REPAIR REPLACEMENT OF TILING JOINERY PLUMBING SANITARY FITTINGS INTERNAL ELECTRIFICATION LT CABLES AND DG SET AT PAO OR LSRC UNDER AGE BR I OF GE 865 EWS
2022_MES_554910_2
865/EWS(NIT-79)/2022-23
Open Tender
Civil Works
Item Rate
270 days
GE 865 EWS
As per tender documents and as per policy in vogue
9 documents required · 9 mandatory
₹500
GE 865 EWS
₹46,000
Yes
13 Jan 2023
5 Nov 2022
6 Dec 2022
5 Nov 2022
28 Nov 2022
13 Nov 2022
Amount
Dismantling wall/floor and ceiling boards (fiber, pulp, inlsulation, blankets) any thickness including covered fillets and supporting members complete all as specified and as directed
Dismantling timber scantling in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section as in framed work complete all as specified and directed.
M&L for 2nd class softwood clean sawn plain fillets, square,rectangular or triangular in section, clean sawn, secured with nails or brads exceeding 13 Sqcm and n.exc 25 Sqcm in section as in framed work complete all as specified and directed.
M&L for 2nd class soft wood clean sawn as in beeding for edges of Ceiling ,lining ,or wooden flooring work fixed with nails exc 6 sqcm and n exc 13 sqcm in section.complete all as specified and as directed.
9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work on walls complete all as specified and as directed by Engr-in-Charge. MAKE: NOVA PAN/GREEN PLY BHUTAN BOARD/MYSORE WOOD BOARD/CENTURY PLYWOOD
9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work on ceiling complete all as specified and as directed by Engr-in-Charge. MAKE: NOVA PAN/GREEN PLY BHUTAN BOARD/MYSORE WOOD BOARD/CENTURY PLYWOOD
Taking down chowkats or frames with shutters (without taking off shutters from frames) area exceeding 1.50 square metre and not exceeding 4.0 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt), complete all as specified and directed by Engineer-in-Charge.
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed by Engr-in-Charge.
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) window and ventilator shutters, side hung type without sash bars, aluminium sections weighing not less than 0.55kg/m including necessary joining cleats, glazing clips, rubber packing, powder coated aluminium snap beading, screws, powder coated aluminium fittings such as peg stays 150mm long - 01 Nos, telescopic hinges 100mm long - 02 Nos, suitable handle - 01 Nos etc in each shutter complete all as specified and directed.
S&F in repair Aluminium door closer hydraulically regulated designation No 3 , universal type, suitable for door shrtters of 851 to 1000 mm in width and weight between 61 to 80 kg and fixed compelte all as specified and directed by Engr-in-Charge. Make : As per PS.
M&L for 4 mm thick plain glass ordinary quality type fixed with oil putty or aluminium beads or fixed to steel etc complete all as specified and directe by Engr-in-Charge
S&F 25 mm bore 3-layer PP-R Polypropylene random copolymer concealed pipes SDR 7.4 (PN 16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass treaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. including taking down of existing pipes of any description complete all as specified and directed by Engr-in-Charge. Make : JINDAL/KISAN/SFMC/Supreme/Kanha Plastic Pvt Ltd
Supply and fixing in replacement PP-R gate valve confirming to ISO 9001- 2000 conforming to IS-15801 screwed down high pressure with crutch or butter fly handle screwed both ends for PP-R pipes or for union and fixed completely as specified for the size 25 mm dia bore complete all as specified and directed bt Engr-in-Charge. Make : JINDAL/KISAN/SFMC/Supreme/Kanha Plastic Pvt Ltd.
M&L for cleaning of blocked/ice frozen drain pipes 100 mm to 200 mm bore by poring hot water, rodding from trap to manhole to septc tank or vice versa and well flushing with water after cleaning including manholes and removing waste material to a distance not exc 50 mtr and burrying in pits and refilling the same complete all as specified and directed by Engr-in-Charge. Note :- The cost of excavation and earth work for pits is deemed to be included in the unit rate.
Demolition of reinforced cement concret as in ground floor of any description and in any position not other wise specifically provided for and Removing demolished material to a distance and depositing out site of MoD land Where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed by Engineer-in-Charge.
Dismantling wrought iron or mild steel work of any description complete all as specified and directed by Engr-in-Charge.
M&L for providing precast reinforced cement concrete type A1, 1:2:4 using 20mm graded aggregate as in landings, cover slabs (for man holes etc) and similar articles with plain faces and setting in cement mortar 1:6 complete with joints to match including use of necessary formwork all as specified and directed. Note : S&F reinforcement shall be measured and paid separately.
S&F mild steel TMT bars of 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia or securing with clips , complete all as specified and directed by Engr-in-Charge.
Demolition of precast concrete block/Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles complete all as specified and directed by Engineer-in-Charge.
M&L for pre cast cement concrete block masonary of 1:3:6, type C-1 (using 20 mm graded crushed stone aggregate) with soild blocks, exc.10cm in width, set and jointed in cement mortor 1:6 complete all as specified and as directed by Engr-in-Charge.
Dismantling of cast iron /PVC or reinforced concrete pipes upto 150 mm bore jointed in cement mortar and taking out of trenches complete all as specified and directed by Engr-in-Charge.
Material and labour for Concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 for 150 mm bore pipes complete all as specified and directed by Engr-in-Charge.
S&F 150mm dia bore (inner dia) double wall corrugated HDPE pipe (SN 8) in any length including all fittings and jointing with eastomeric rubber link and cuppler/other jointing materials laid in trenches or in floor all as specified and directed by Engr-in-Charge Make : ALOMK/GEMNI/REX
S&F 110mm dia bore PVC pipes single socketed having compressive strength 655 - 675 Kg/Cm2 , in any length with rubber ring joints , laid in trenches or in floors including PCC 1:4:8 type D-2 (using 40mm draded aggregate) bed to drain complete all as specified and directed by Engr-in-charge.
S&F110mm bore PVC (SWR) pipe bends any radius complete all as specified and directed by Engr-in-Charge.
Taking down cement or cement lime plaster, any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc, including cutting of trees, shrubs or any type of vegitation upto and including roots complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15 mm thick rendering in cement mortar 1:6 on fair faces of brick walls or on concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by Engr-in-Charge.
M&L for rendering 15 mm thick rendering in cement mortar 1:4 on fair faces of brick walls or on concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by Engr-in-Charge.
M&L for Preparation of old treated plastered / unplastered surfaces of walls and applying two coats of cement base paints of any shade on walls (shade as approved by users) including curing before and after applying each coat complete all as specified and directed by Engineer-in-Charge. Make as per PS.
M&L for preparation of new plastered/concrete surfaces of wall and applying 1 to 2 mm thick JK / Birla wall putty in two layer as per manufactures instructions, surfaces to be finished even and smooth over a coat of alkali resisstane primer and applying two coats of oil emulsion distember first quality of approved colour complete all as specified and directed by Engr-in-Charge.
M&L for one coat of synthetic enemal paint old treated on steel surfaces including preparation complete all as specified and direceted by Engr-in-Charge.
M&L for one coat of synthetic enemal paint on old treated wooden surfaces including preparation complete all as specified and direceted by Engr-in-Charge.
Taking down carefully copper/Aluminum point wiring (Light, Fan, Socket or power) complete fitting such as switches, ceiling, regulator, sockets etc removing materials to be store for keeping in safe custody for taking credit and making good disturbed surfaces of walls, floors etc complete all as speciifed and directed by Engr-in-Charge.
M&L for point wiring complete with 1.5 Sqmm nominal area of copper conductor multi strandared FRLS PVC insulated and unsheathed 1100 Volts for one light/exhaust point or fan point controlled by one light/exhaust fan controlled by one way switch with including PVC casing/caping fixed with screw and fisher, terminated in existing sunk CI/pressed steel terminal boxes for fixing and 1.5 sqmm PVC insulated copper wire as earth wire connected to earth wire connected to earth dolly and 3.0mm thick plastic laminated sheet cover all as specified and directed by Engr-in-Charge.
All as per item No. 35 here-in-before but 1.5 Sqmm for one 3 pin 6 Amps socket outlet including 1.5 sqmm insulated copper wire as earth wire to the same earth dolly on the same board complete all as specified and directed by Engr-in-Charge.
All as per item No. 34 here-in-before but 1.5 Sqmm for one 3 pin 6 Amps socket outlet including 1.5 sqmm insulated copper wire as earth wire to the same earth dolly on the independent board complete all as specified and directed by Engr-in-Charge.
All as per item No 35 here in before but using 4 Sqmm cable in size compelte all as specified and directed by Engr-in-Charge
S&F in replacement for one way Switch piano flush button single pole 6 Amps 240 volt one way complete all as specified and directed by Engr-in-Charge.
S&F in replacement of switch socket 5 pin, 6 Amps flush type, 240 volts universal complete all as specified and directed by Engr-in-Charge
S&F in replacement of switch socket combination 2 in 1, 5 pin, 5/6 Amps, 240 volt flush type universal complete all as specified and directed by Engr-in-Charge
S&F in replacement of ceiling rose surface bakelite 65x50 mm two to three terminals complete all as specified and directed by Engr-in-charge.
S&F in replacement of 9 W LED bulb including testing complete all as specified and directed by Engr-in-Charge.
S&F in replacement of 7 W LED bulb including testing complete all as specified and directed by Engr-in-Charge.
S&F in replacement of 5 W LED bulb including testing complete all as specified and directed by Engr-in-Charge.
M&L in replacement of lamp holder PVC/Poly corbonate type insulated body with back plate suitable for batten fittings as specified and directed by Engr-in-Charge.
S&F in replacement of Endura slim pro plus 2' x 2' aesthetically designed LED flat panel which provides soft light and glare free symetrical illumination also for POP celing 36 W slim type with separate driver model strato2x2pir36wled857 mod of make Havells or equivalant make of PS. complete all as specified and directed by Engr-in-Charge.
S&F in replacement of LED single tube light fittings surface pendent mounting complete with batten for LED tube light 20 watt with extruded aluminium housing provided for efficent heat dissipation with polycorbonate diffuser and integrated electronic driver complete all as specified and directed by Engr-in-Charge.
S&F in replacement of suface mounted Bulk head fittings environmental frendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge-lit LED luminare comprising of high brightness LEDs 10 watt model Hexaft10wled857ssYmBoPC make - Havells or equivalant make of PS.
Supply and fixing of exhaust fan, plastic body, AC single phase 230 volts of size 250 mm sweep including taking down the existing exhaust fan and making necessary arrrangement and connecting with flexible three core cable from the ceiling rose with blades and frame and louvers complete all as specified and as directed by Engr-inCharge Make as per PS.
S&F in replacement of change over switch 415 volt in sheet mental enclosure 4 pole of capacity 400 Amps with connecting acessories complete all as specified and directed by Engr-in-Charge.
Supply and laying, in replacement of jointing and testing cable XLPE insulate, screened, PVC bedded galvanised steel strip or wire armoured, electric power ccable heavy duty 1100 volts grade with sith stranded aluminium conductor in size 10 Sqmm 2 core complete all as specified and directed by Engr-in-Charge. Make as per PS.
M&L for Checking, Inspection, maintanance and servicing complete including replacement of unserviceable spare parts of the DG set (comprising of Engine/ Alternator/ Control panel) of the following capacity for smooth functioning complete all as per manufacturers instructions and all as directed by Eng in Charge including the following works also: - A:(a) Checking of lubricating oil condition, (b) Checking engine for oil, water leakage and correcting the same (c) Checking of all the nut bolts of engine and alternator, (d) Checking of all belts and adjust the tension properly, (e) Cleaning of air filters, (f) Checking and readjusting the valve clearance, (g) Change of Oil/Fuel filters and engine oil if necessary, (h) Checking of starter motor battery and charger, (i) Checking of cooling system and fuel system, (j) checking of all power cables and AVR connections and mounting bolt tightnees of alternator, (k) checking the function of AVR genaral checks, (l) Checking of control panel meters and gadgets functioning, (m) Checking of all control and safety wirings. B. (a) Checking of flexible coupling of engine and alternator, (b) Cleaning of crank case ventilation pipe, (c) Checking of injectors and fuel pump, (d) Checking of alternator and carbon brushes of following capacity DG sets: - Note (1) Cost of Spare parts required will be measured and paid separately, (2) Servicing/routine check up carried out through authorised service centre of manufacturer, (3) Make of spare recommendation by auth service centre of manufacturer. (i) 250 KVA DG Set
M & L for changing /toping up of best quality of engine oil 20W40 type for 250 KVA DG sets including removing of old burnt engine oil from DG Sets complete all as specified and directed . Make Castrol/ Veedol/ Valvoline.
S&F in replacement of Oil Filter Element for DG Sets of 250 KVA Make Kirloskar/Cummins/Greaves complete all as specified and directed by Engr-in-Charge Make :- Kirloskar/Mico/TVS
S&F in replacement of Air cleaner Element (inner and outer) for DG Sets of 250 KVA Make Kirloskar/Cummins/Greaves complete all as specified and directed by Engr-in-Charge
S&F in replacement of Fuel filter Element (Primary & Secondary) of DG Set 250 KVA Make Kirloskar/Cummins/Greaves complete all as specified and directed by Engr-in-Charge
S&F Battery 12 volt 180 AH (maint free) heavy duty complete all as specified and directed by Engr-in-Charge. Make Exide/Amaron/Luminous/V Guard
S&F replacement of auotmatic voltage regulator (AVR) 24 volt suitable for DG Sets 250 KVA Make Kirloskar/Cummins/Greaves complete all as specified and directed by Engr-in-Charge
S&F in Replacement of self starter DG Set of 250 KVA Make Kirloskar/Cummins/Greaves complete all as specified and directed by Engr-in-Charge
S&F in Replacement of 'V' belt for radiator/water pump suitable DG Sets of 250 KVA Make Kirloskar/Cummins/Greaves complete all as specified and directed by Engr-in-Charge
Supply and topping up of best quality antifreezing, inhabitor (Coolant) liquid for DG Set of various capacity and locations complete all as specified and directed.
M&L for dismantling the defective radiator assembly and taking it to contractor workshop for cleaning of radiator, finding the leakages by pressure method and providing leak proof treatment to defective radiator assembly by welding/brazing/glazing suitable material for cohessiveness for 250 KVA DG sets cleaning solution (ready to wash) by pressure of pump and brush and re-assembling after painting of the same complete all as specified and directed by Engr-in-Charge.
M&L for removing the fuel injection pumb (FIP) and injetors from the following capacity of DG sets and carry out servicing and calibration including repacement of injector nozzles, etc and refitting the same for smooth and efficent functioning all as directed by Engr-in-Charge Note:- Repairs will be carried out from authrosied workshop of MICO or manufacturer of DG set
Material and labour for in replacement of Earthing complete with galvanised iron earth plate electrode 600x600x6mm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, connected with 25x4 mm size GI strip as earth lead, by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 40mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15, type B-1 in pit with precast RCC M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates) in cover reinforced with XPM not less than 4.0 Kg per Sqm, test point etc. all as shown in electric plate No-3 of SSR Part-I (2009), complete with necessary earth work in any type of soil, removal to a distance not exceeding 50mtr, including testing on completion, complete all as specified and as directed by Engineer-In-Charge. Note: Earth pit chamber and RCC pit cover shall be painted with two coats of red synthetic enamel paint over one coat of primer including preparing of surfaces.
Material and labour for in replacement of earthing complete with galvanised steel earth plate 600 x 600 x 6 mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level connected to and including GI wire of size 4 mm dia by means of nuts, bolts, washers etc made of and connected to test point and earth dolly as all shown in electrical plate No.3 of SSR Part-I 2009 and specified or indicated including excavation and earth work in any type of soil PCC (1:3:6) type C1 in chamber, pre cast RCC slab 50mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM jali (weight not less than 4.0 kg/Sqm) with cast iron frame, funnel, with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore light grade GI protection pipe, test point, etc, incluidng taking down of old u/s earthing set complete all as specified and as directed. Note: (i) Item includes the cost of 7.5 m GI pipe for protection of earth lead. Any additional length shall be adjusted through deviation order. (ii) Item includes the cost of 7.5 m GI earth lead. Any additional in length shall be adjusted through deviation order ( For Main DBs ) (iii) Item includes the cost of Charcoal and commercial salt ( For Main DBs )
M&L for in replacement of Sub main wiring with two run of 2.50 Sqmm (2x2.50 sqmm) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC casing caping ISI marked with all accessories etc with one run of2.50 Sqmm (1x2.50sqmm) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire and making good to match with existing surfaces including taking down of old sub main wirings complete all as specified and directed by Engineer-in-Charge. Note:- 2 runs of 2.50 Sqmm (2x2.50sqmm), one run of 2.5 Sqmm (1x2.5 sqmm) cable and one metre of PVC casing caping will be measured as one unit. Make of cable: As per PS.
Supply, fixing, in replacement of connecting and testing street light LED type suitable for working on 230 volts, 50 Hz, AC of 60 Watts, including connection of copper wire complete all as specified and directed by Engr-in-Charge. Make : As per PS
Supply and fixing in replacement of MCB distribution board Double door, regal grey, sheet metal enclosure, SPN 240 volts 4 way with 200 amps rated bus bar concealed to wall and making flush with wall surfaces and making good to disturbed surfaces of walls to match with the exisiting surface etc . Make: Cat part No 5076 11 of Legrand (Ekinoxe) or equvalant make of PS.
Supply and fixing in replacement of MCB distribution board Double door, regal grey, sheet metal enclosure, SPN 240 volts 8 way with 200 amps rated bus bar concealed to wall and making flush with wall surfaces and making good to disturbed surfaces of walls to match with the exisiting surface etc . Make: Cat part No 5076 11 of Legrand (Ekinoxe) or equivalant make of PS.
S&F in replacement of MCB (SPN), 40 Amps, 240 Volts, AC ISI marked complete all as specified and directed by Engr-in-Charge.
S&F in replacement of MCB (SPN), 6 to 32 Amps, 240 Volts, AC ISI marked complete all as specified and directed by Engr-in-Charge.
Supply and replacement of plug top, 3 pin, 15 Amps earth mental clad ISI marked complete all as specified and directed by Engr-in-Charge.
Supply and laying, in replacement of jointing and testing cable XLPE insulate, screened, PVC bedded galvanised steel strip or wire armoured, electric power ccable heavy duty 1100 volts grade with sith stranded aluminium conductor in size 50 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge. Make as per PS.
Supply and laying, in replacement of jointing and testing cable XLPE insulate, screened, PVC bedded galvanised steel strip or wire armoured, electric power ccable heavy duty 1100 volts grade with sith stranded aluminium conductor in size 35 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge. Make as per PS.
Supply and laying, in replacement of jointing and testing cable XLPE insulate, screened, PVC bedded galvanised steel strip or wire armoured, electric power ccable heavy duty 1100 volts grade with sith stranded aluminium conductor in size 25 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge. Make as per PS.
Supply and laying, in replacement of jointing and testing cable XLPE insulate, screened, PVC bedded galvanised steel strip or wire armoured, electric power ccable heavy duty 1100 volts grade with sith stranded aluminium conductor in size 16 Sqmm 4 core complete all as specified and directed by Engr-in-Charge. Make as per PS.
Excavating in trenches, n. exc 1.5 m wide and n. exc 1.5 m depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying cables/pipes, etc. n exc 10 sq m on plan in hard/dense soil and getting out soil, complete all as specified and as directed by Engineer-in-charge.
Returning filling in (soil) including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in any type of soil complete all as specifed and as directed by Engineer-in-Charge.
Removal of excavated material (soil) to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specifed and as directed by Engineer-in-Charge.
Sand cushining for cables 8 cm below the cable and 15 cm above the cable and punned thickness of 18 CM will be measured and paid separately compelte all as specified and directed by Engr-in-Charge.
Supply and laying in replacement of un-reinforced precast concrete cover LV type-I flat size 250 x 150x 40 mm complete all as specified and directed by Engr-in-Charge.
Supply and laying in replacement of Galvanised iron tubes, light grade 50 mm dia including all fitting laid in trenches or fixed to wall and posts complete all as specified and directed by Engr-in-Charge. Make: As per PS
Supply and replacement of electric cable PVC insulated rubber sheathed circular multistranded copper conductor of size 2.5 sqmm 3 core complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of heating element suitable for water storage heater vertical type ORISON/PEARL make 220/240 Volt, AC, 2000 watts and making connections and testing complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of heavy duty PVC connection armoured type with brass union, nut, heat resistance type rubber washer for hot water complete all asspecified anddirected by Engr-in-Charge.
Rampal Singh Contractor
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .