| 1 | L1₹27.7 LAccepted-AOC 53 13 A OUTER CIRCULAR ROAD KILPAUK GARDEN COLONY CHENNAI 600 010 | CHENNAI | CHENNAI | TAMIL NADU | 600010 | L1 | Accepted-AOC Being the lowest tenderer and fulfilling all the criteria | |
| 2 | L2₹29.6 L+₹98,370 (3.43%)Rejected-Finance NO 13 B 31 JEGAJEEVAN RAM STREET ANANDANPURAM EAST TAMBARAM CHENNAI 600 059 | CHENGALPATTU | TAMIL NADU | 600059 | L2 | Rejected-Finance Not being the lowest tenderer | |
| 3 | L3₹32.6 L+₹4.0 L (13.9%)Rejected-Finance NO 235 PSK ILLAM SANKARAN NAGAR CHINNAMMAN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L3 | Rejected-Finance Not being the lowest tenderer | |
| 4 | L4₹33.0 L+₹4.3 L (15.0%)Rejected-Finance 131 SANGAM NAGAR OPP NATIONAL SCHOOL SANGHVI PUNE 411027 | PUNE | MAHARASHTRA | 411027 | L4 | Rejected-Finance Not being the lowest tenderer | |
| 5 | L5₹33.8 L+₹5.1 L (17.8%)Rejected-Finance OLD NO 338 NEW NO 17 19TH NEDUMANEHLIAN STREET G K M COLONY CHENNAI 600 082 | CHENNAI | CHENNAI | TAMIL NADU | 600082 | L5 | Rejected-Finance Not being the lowest tenderer |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
24 Feb 2022, 6:00 pmClosed
Garrison Engineer Chennai
Garrison Engineer Fort Saint George, Chennai
REPAIR MAINTENANCE OF LT EXTERNAL ELECTRIFICATION SUB STATION AND ITS ALLIED WORKS AT ZONE A B AND D AREA UNDER GE CHENNAI
2022_MES_503941_1
8572/E8
Open Tender
Electrical and Maintenance Works
Item Rate
243 days
Fort Saint George
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
₹84,000
Yes
12 May 2022
27 Jan 2022
2 Mar 2022
27 Jan 2022
24 Feb 2022
10 Feb 2022
Amount
BOQ UPLOADED ON 04 FEB 2022
Excavation in trenches in soft/ loose soil n. exc. 1.50m wide and n. exc. 1.50m deep for taking out/ laying cables, CI/ GI/ DI/ HDPE pipe line and getting out complete all as specified and directed.
Returning filling in including spreading, leveling, watering & well ramming in layers not exceeding 25cm thick in soft/ loose soil complete all as specified and directed.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Supply, laying/ spreading in trenches clean dry sand to required width and depth at bottom and top of cable including spreading, levelling, punning for laying/ cushioning of cable all as specified and directed. Note: Punned thickness only will be considered or payment.
Supply and laying burnt bricks, old size, sub class 'B', laid flat abutting each other, perpendicular to cable with width equal to width of brick laid in trenches for protection of cable all as specified and directed.
Laying only old size burnt bricks, laid flat abutting each other, perpendicular to cable with width equal to width of brick laid in trenches for protection of cable all as specified and as directed. Note: Old re-useable bricks obtained during taking out of cable shall be re-used.
Taking out existing PVC/ XLPE cable 1100 volts grade LT cable of size 6 sqmm 2 core with glands, bricks/ cable protection pipe, cable route indicators etc. from the trench/ fixed along wall or passing through pipes/ in floor, removing the unserviceable/ faulty cable and stacking serviceable cable for re-use complete all as specified and directed. Note: Excavation and earthwork will be measured and paid separately under appropriate items.
All as per item No. 7.00 above but cable size 10 sqmm 2 core.
All as per item No. 7.00 above but cable of size 25 sqmm 3½ core.
All as per item No. 7.00 above but cable of size 35 sqmm 3½ core.
All as per item No. 7.00 above but cable of size 50 sqmm 3½ core.
All as per item No. 7.00 above but cable of size 95 sqmm 3½ core.
All as per item No. 7.00 above but cable of size 150 sqmm 3½ core.
All as per item No. 7.00 above but cable of size 185 sqmm 3½ core.
All as per item No. 7.00 above but cable of size 240 sqmm 3½ core.
Laying only old serviceable cable of size 25 sqmm 3½ core including jointing, testing and commissioning complete all as specified and directed. Note: Old serviceable cable as obtained from taking down shall be re-used after testing as directed.
All as per item No. 16.00 above but cable of size 35 sqmm 3½ core.
All as per item No. 16.00 above but cable of size 50 sqmm 3½ core.
All as per item No. 16.00 above but cable of size 95 sqmm 3½ core.
All as per item No. 16.00 above but cable of size 150 sqmm 3½ core.
All as per item No. 16.00 above but cable of size 185 sqmm 3½ core.
All as per item No. 16.00 above but cable of size 240 sqmm 3½ core.
Supply and laying in trenches, fixed on wall (or) passing through pipes/ in floors including connecting up, testing and commissioning of XLPE insulated screened PVC bedded galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 Sqmm 2 core complete all as specified and directed.
All as per item No. 23.00 above but cable size 10 sqmm 2 core.
All as per item No. 23.00 above but cable of size 25 sqmm 3½ core.
All as per item No. 23.00 above but cable of size 35 sqmm 3½ core.
All as per item No. 23.00 above but cable of size 50 sqmm 3½ core.
All as per item No. 23.00 above but cable of size 95 sqmm 3½ core.
All as per item No. 23.00 above but cable of size 150 sqmm 3½ core.
All as per item No. 23.00 above but cable of size 185 sqmm 3½ core.
All as per item No. 23.00 above but cable of size 240 sqmm 3½ core.
M&L cable jointing kit for 1100 volts grade cable for straight through heat shrink type joints complete with jointing material and accessories suitable for 25 to 70sqmm 3½ core XLPE armoured aluminium conductor cable complete all as specified and directed.
All as per item No. 32.00 above but for 95 to 120sqmm 3½ core cable.
All as per item No. 32.00 above but for 150 to 185sqmm 3½ core cable.
All as per item No. 32.00 above but for 240 to 300sqmm 3½ core cable.
Supply and laying GI tube light grade 50mm bore with all fittings laid in trenches/ floor for cable protection and for drawing earth strip/ earth lead wire etc., complete including taking down old pipe complete all as specified and directed.
Supply and laying GI tube light grade 80mm bore with all fittings laid in trenches/ floor for cable protection and for drawing earth strip/ earth lead wire etc., complete including taking down old pipe complete all as specified and directed.
Supply and laying GI tube light grade 100mm bore with all fittings laid in trenches/ floor for cable protection and for drawing earth strip/ earth lead wire etc., complete including taking down old pipe complete all as specified and directed.
M&L taking out existing LT underground cable PVC/ XLPE insulated 1100 volts grade of size 16 sqmm to 25 sqmm and re-fixing in panel by providing 4 No. aluminium lugs with crimping tools including providing insulation tap around the burnt cable complete all as specified and directed.
M&L taking out existing LT underground cable PVC/ XLPE insulated 1100 volts grade of size 50 sqmm to 70 sqmm and re-fixing in panel by providing 4 No. aluminium lugs with crimping tools including providing insulation tap around the burnt cable complete all as specified and directed.
M&L taking out existing LT underground cable PVC/ XLPE insulated 1100 volts grade of size 95 sqmm to 150 sqmm and re-fixing in panel by providing 4 No. aluminium lugs with crimping tools including providing insulation tap around the burnt cable complete all as specified and directed.
M&L taking out existing LT underground cable PVC/ XLPE insulated 1100 volts grade of size 185 sqmm to 240 sqmm and re-fixing in panel by providing 4 No. aluminium lugs with crimping tools including providing insulation tap around the burnt cable complete all as specified and directed.
Supply, fix, connecting and testing MCCB three pole 125 Amps, 415 volts breaking capacity, 16kA with adjustable thermal and magnetic setting including taking down the existing one complete all as specified and directed.
Supply, fix, connecting and testing MCCB four pole 160 Amps, 415 volts breaking capacity, 36kA with adjustable thermal and magnetic setting including taking down the existing one complete all as specified and directed.
Supply, fix, connecting and testing MCCB four pole 200 Amps, 415 volts breaking capacity, 36kA with adjustable thermal and magnetic setting including taking down the existing one complete all as specified and directed.
Supply, fix, connecting and testing MCCB four pole 250 Amps, 415 volts breaking capacity, 36kA with adjustable thermal and magnetic setting including taking down the existing one complete all as specified and directed.
M&L for preparing old painted steel surface (LT panel of any size and type) of any description over 10cm width or girth and applying two coats of synthetic enamel grey colour paint after thoroughly burning the existing paint including repairing the LT panel door by tack welding as required complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 6.0mm thick buried directly in ground vertically to a depth of not less than 2.25 mtr below normal ground level with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip of size 25 x 4mm as earth lead by means of bolts, nuts and washers of galvanised iron, protected by means of 40mm dia light grade GI pipe all as specified and shown in MES schedule electrical plate No. 3 of SSR (Part-I) including necessary excavation and earth work in soft/ loose soil, PCC (1:3:6) type C-1 in chamber, 50mm thick RCC (1:2:4) type B-1 cover slab with 8mm dia MS bars at 100mm centre to centre both ways and MS 6mm dia hook, charcoal dust, salt, funnel for watering complete and testing the earth resistance and writing on the chamber by paint including demolition of existing earthing complete all as specified and as directed.
S&F ON LOAD change over switch in sheet steel enclosure change over switch 4 pole, compact design type 415V AC, 50 Hz, 200 Amps, 4 pole conforming to IS 13947-3 including taking down the old change over switch complete all as specified and directed.
S&F OFF LOAD change over switch in sheet steel enclosure change over switch 4 pole, compact design type 415V AC, 50 Hz, 100 Amps, 4 pole conforming to IS 13947-3 including taking down the old change over switch complete all as specified and directed.
M&L for opening 1250 Amps, LT, 11KV, VCB front and back side complete after taking shutdown, cleaning the dusting inside & outside of VCB, greasing, oiling the mechanical parts of VCB and complete servicing including the following :- (a) Replacement of nuts/ bolts. (b) Replacement of insulators. (c) Replacement of protect release (8538). (d) Replacement of shunt release (8538). (e) Repair and replacement of under voltage release. (f) Repair and replacement of earth fault release. (g) Repair and replacement of service position micro switch right (2). (h) Repair and replacement of service position micro switch left (2). (j) Repair and replacement of vertical thermal adopter. Notes:- (i) The numerical in brackets against various accessories indicate the SIC's required for wiring purpose in draw out brackers. (ii) Shunt release requires one set of auxiliary contacts. (iii) Maximum 24 SIC's can be fitted on ACB. Electrical ACB's are pre-wired for control circuit purpose.
M&L for opening 630 Amps, LT, 11KV, VCB front and back side complete after taking shutdown, cleaning the dusting inside & outside of VCB, greasing, oiling the mechanical parts of VCB and complete servicing including the following :- (a) Replacement of nuts/ bolts. (b) Replacement of insulators. (c) Replacement of protect release (8538). (d) Replacement of shunt release (8538). (e) Repair and replacement of under voltage release. (f) Repair and replacement of earth fault release. (g) Repair and replacement of service position micro switch right (2). (h) Repair and replacement of service position micro switch left (2). (j) Repair and replacement of vertical thermal adopter. Notes:- (i) The numerical in brackets against various accessories indicate the SIC's required for wiring purpose in draw out brackers. (ii) Shunt release requires one set of auxiliary contacts. (iii) Maximum 24 SIC's can be fitted on ACB. Electrical ACB's are pre-wired for control circuit purpose.
Testing the underground or on the surface cable to find out the fault with location and locate all types of faults core to core, core to earth, short or low insulation upto 1 mega ohm in cable irrespective of location rating of transmission of power and length of cable from start point and any size of cable complete all as specified and directed.
S&F GI strip of size 25mm x 4mm complete with necessary nuts, bolts and washers buried in ground fixed in replacement complete all as specified and directed.
M&L for 60mm thick M-35 grade machine pressed precast concrete interlocking paver block any shape and size conforming to IS: 15658-2006 with grey cement and no pigment laid as per manufacturer's instructions laid over and including 50mm thick layer of sand cushioning including demolition of existing pavers complete all as specified and directed.
Supply, install, test & commissioning LT panel outdoor, floor mounted/ pedestal type, cubical, self supported, CPRI approved make, front and rear openable, double door hinged type with locking arrangement and suitable ventilations on both sides with wire mesh, IP-65 protection, fabricated out of 3mm CRCA sheet duly powder coated, mounted/ fixed on and including MS angle iron stand of 50cm height above ground, fabricated out of 50mm x 50mm x 6mm thick MS angles duly painted with black enamel synthetic paint over a red oxide primer duly grouted in PCC (1:3:6) type C-2 using graded stone aggregate as in foundation, control wiring copper stranded PVC insulated FRLS cables not less than 1.5sqmm, interconnection of suitable size/ capacity of copper strips for switch gear connection from main bus bar four run including earth bus strip of 300A capacity for entire length of panel, suitable size of MS gland with gland plate and aluminium lugs/ thimbles for all incoming/ outgoing cables etc. complete and including taking down the old panel and accommodating the followings: (A) INCOMING: MCCB with adjustable thermal & magnetic setting 4 pole 250 Amps, 25 KA, 415 volts - 01 No.
S&F street light panel, 3 phase, digital 24 hours timer with 32 Amp TP contactor and 40 Amp TPN MCB provided with inbuilt circuit protection with protection degree IP 54 suitable for 6 KW load including taking down old street light panle complete all as specified and directed. Make: Havells Cat No. IHXTS03060 OR equivalent from other makes specified in particular specifications.
S&F street light panel, 3 phase, digital 24 hours timer with 65 Amp TP contactor and 63 Amp TPN MCB provided with inbuilt circuit protection with protection degree IP 54 suitable for 12 KW load including taking down old street light panle complete all as specified and directed. Make: Havells Cat No. IHXTS09120 OR equivalent from other makes specified in particular specifications.
M&L painting to LT steel tubular poles 8.5/ 9Mtr long including all fittings and fixtures complete, fixed with poles with one coat of aluminium paint after scrapping of rust and preparation of surfaces complete all as specified and directed.
M&L for writing letters and figures in white enamel in black Roman, Italic or Indian of 10 cm height including circular back ground with black enamel paint of two coats and white circular border over steel/ RCC surfaces of electric poles complete all as specified and directed.
power engineer
PSK Enterprises
LEO ENTERPRISES
GK ENTERPRISES
EVEREST ENGINEERING WORKS
G.L.THIRUMALAI NAIDU AND COMPANY
Anand electrical
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .