| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 LAccepted-Finance MEGHNATH SAHA ROAD P O PANIHATI KOLKATA 700114 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700114 | ₹2.4 L | L1 | Accepted-Finance Lowest |
| 2 | L2₹2.5 LRejected-Finance | ₹2.5 L | L2 | Rejected-Finance 2nd Lowest |
| 3 | L3₹2.5 LRejected-Finance 112 JAGAT BERH SRIPALLY 713103 PURBA BARDHAMAN WEST BENGAL | BARDHAMAN | PURBA BARDHAMAN | WEST BENGAL | 713103 | ₹2.5 L | L3 | Rejected-Finance 3rd Lowest |
| 4 | L4₹2.6 LRejected-Finance 585A UPEN BANERJEE ROAD PARNASREE KOLKATA 700060 | KOLKATA | KOLKATA | WEST BENGAL | 700060 | ₹2.6 L | L4 | Rejected-Finance 4th Lowest |
| Sl No | Description | Qty | Unit | Zenith Enterprises L2 | JOY MAA TARA ELECTRICAL CO L3 | KAJAL CHANDRA L1 | M.N. ENTERPRISES L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR'(Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 3 no. suitable size “Ph & N, E" copper bar attachment fixed on wall incl. mending good damages to original finish. Average run 8 mtr | 14 | Point | 1,175 ₹16,450 | 1,180 ₹16,520 | 1,156.05 ₹16,184.64 | 1,177 ₹16,478 |
| 1.20 | on board | 2 | Each | 260 ₹520 | 270 ₹540 | 257.43 ₹514.86 | 268 ₹536 |
| 2.00Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required | |||||||
| 2.10 | 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC | 30 | Mtr | 125 ₹3,750 | 126 ₹3,780 | 121.56 ₹3,646.91 | 125 ₹3,750 |
| 2.20 | 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC | 45 | Mtr | 150 ₹6,750 | 151 ₹6,795 | 141.82 ₹6,382.09 | 151 ₹6,795 |
| 2.30 | 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC for AC | 30 | Mtr. | 190 ₹5,700 | 190 ₹5,700 | 177.58 ₹5,327.35 | 191 ₹5,730 |
| 3.00Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. | |||||||
| 3.10 | 3 x (1.5 sqmm) | 4 | Set | 21 ₹84 | 22 ₹88 | 6 ₹24 | 21 ₹84 |
| 3.20 | 2 x (2.5 sqmm) + 1 x (1.5 sqmm) | 6 | set | 21 ₹126 | 22 ₹132 | 14 ₹84 | 21 ₹126 |
| 3.30 | 2 x (4 sqmm) + 1 x (2.5 sqmm) | 4 | set | 24 ₹96 | 25 ₹100 | 21 ₹84 | 25 ₹100 |
Tender Value
₹2.5 L
EMD Value
₹5,080
Closing Date
3 Jan 2026, 3:00 pmClosed
AEWBESDPWD
Block I Ground Floor Writers Buildings Kolkata 700001
Electrical repairing and renovation works incl. SITC of AC installation work at the department of Dalit Bandhu Welfare Development Board 4th Floor at Mitra Buildings, Lyons Range, BBD Bag Kolkata.
2025_WBPWD_965586_1
WBPWD/AE/WBESD/eNIQ-29 of 2025-26
Open Tender
ELECTRICAL WORKS ORG
15 days
Mitra Building
Please refer Tender documents.
6 documents required · 6 mandatory
₹5,080
9 Jan 2026
2 Dec 2025
5 Jan 2026
2 Dec 2025
3 Jan 2026
8 Dec 2025
Amount
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR'(Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 3 no. suitable size “Ph & N, E" copper bar attachment fixed on wall incl. mending good damages to original finish. Average run 8 mtr
on board
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required
2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC for AC
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
3 x (1.5 sqmm)
2 x (2.5 sqmm) + 1 x (1.5 sqmm)
2 x (4 sqmm) + 1 x (2.5 sqmm)
S&F 240 V, 1 no. 16 A, 5 pin Modular type plug socket with 1 no. 16A Modular type switch (Brand approved by EIC) & 3 nos. 6A Modular type plug socket with 3 nos. 6A Modular type switch and Indicator without plug top on 16 Module GI Modular type switch board with 16 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. Make (Legrand myrius/Schneider/ABB)
S&F 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 2 nos 6 A, 3 pin Modular type plug socket (Brand approved by EIC) with 2 nos 6A Modular type switch, without plug top on 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etcMake (Legrand myrius/Schneider/ABB)
S&F 240 V, 6 A, 3 pin Modular type plug socket (Brand approved by EIC) with 6A Modular type switch, without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
S&F 21A, single ph AC OLP 3+ starterwith over voltage/undervoltage protection on 2 module GI Box with necy. Connections as per GS
S & delivery of 240V,90W, minimum rpm 1325rpm, 3-blades, AC Full body metal wall bracket fan (motor housing canopy should be metalic and inbuild thermostate protection )450 mm or 18 inch on wall by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) on 150mmX300mm best quality vernished wood or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length Make orient Tornado Wall - II/ crompton strom 2/EPC
Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length
Supply & Delivery 230V, Recess Mounted 2'x2' LED,36W,Min 3600lm high efficient light , white(4000 to 5700K) slim pannel light fitting for false ceiling (Make:Wipro,Philips(signify) or equivalent) (warrenty should beTwoyears )(the light should be connected through two way terminal connector and Gi flexible wire to protect rat bite effect)
Fixing of above Light on false ceiling by hanging GI Wire from ceiling to Both end of The light incl necy Electrical Connection & as per direction of the E. I. C.
Supplying &delivery wireless 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board
S & F Acrylic Edge Light Engaged Board(Red colour) wiith 12 Volt smps.(Make-Bajaj)
Supply & delivery of Hi- wall Inverter type Split Air conditioner having following specification: Minimum Cooling Capacity(Kcal/Hr)- 6000K.Cal/hr Or 6900W ISEER Rating - 3.8-4.39 /2022-2024 as per BEE/BIS IS Compliance- IS 1391 Refrigerant- R410A/R32 Compressor - Rotary/ Scroll Evaporator & Condenser Coil: Copper LCD Remote and All other accessories operating outdoor Temperature - 50°C Power supply - 240 V,50Hz(+ Tolerrance as per applicable standard) Make:- O-General/ Mitsubishi Electric/ Daikin/ Hitachi
Installation Testing & commissioning of the above Said Split Acs incl. Supply & fixing required Angle iron structure on wall for placing outdoor unit and mending Good the damages as per direction of EIC
S & Installation of Extra Add-on Items HVAC grade 5/8"(for suction) & 1/4"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle, screws, insulation tape, fasner etc for above AC machines as per direction of EIC.
Supply & Laying 1.1KV grade 3 core 4 sqmm flexible copper cable with screw, saddle drill machine nut bolt etc all necy. items needed for connection.(from starter to AC outdoor connection)(Make: Havells/KEI/Polycab/Fenolex as per approved by EIC)
Supply & Laying 20mm hard PVC pipe(heavy type) for water discharge(Make: supreme )
S & F 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supplying, fabrication & fixing M.S. Angle Frame for installation of 2 nos Outdoor unit . the structure having 5 nos 50 x 50 x5 mm MS angle for main bottom support grouted on wall with total length 16' and in between main support 7 nos 25 x 5 mm ms strip . For railing vertical & horizontal support is made by 25 x 25 x 5 mm Angle for safety of maintenance , total length 35' ; including cutting holes , welding , painting and mending good damage as per EIC
Dismentling of all existing light points, fan points , computer boards, ,old damage wiring and other defunction materials as per site requirment and mending to good damage as per direction EIC
Zenith Enterprises (BID ID -7589579)
JOY MAA TARA ELECTRICAL CO (BID ID -7627069)
M.N. ENTERPRISES (BID ID -7627167)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid