Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹47.5 L+₹2.3 L (5.09%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹47 L+₹1.8 L (3.98%)Rejected-Finance 429 FUNCTIONAL INDUSTRIAL ESTATE PATPARGANJ EAST DELHI DELHI 110092 | EAST DELHI | DELHI | 110092 | L3 | Rejected-Finance L3 | |
| 4 | Rejected-Technical 147 UDHYOG VIHAR PH I GURGOAN HARYANA 122016 | GURUGRAM | HARYANA | 122016 | - | Rejected-Technical Disqualified |
Tender Value
Refer Docs
EMD Value
₹90,480
Closing Date
28 May 2024, 3:00 pmClosed
MD, WBMSCL
Swasthya Sathi, GN-29, Sector-V, Salt Lake, Kolkata 700091
Repair and renovation of IC Building (Gplus4 storied) of Medinipur Medical College and Hospital in the District of Paschim Medinipur-SITC of Lifts.
2024_WBMSC_679959_1
WBMSCL/NIT-165/2024 Dated 05/03/2024
Open Tender
Electrical Work/ Equipment
Item Rate
45 days
Paschim Medinipur MCH
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹90,480
Conference Room of WBMSCL, Swasthya Sathi Building
24 Sept 2024
6 Mar 2024
29 May 2024
6 Mar 2024
28 May 2024
11 Mar 2024
7 Mar 2024
Amount
Supply installation testing & commissioning of New 13 Passenger-884KG Elevator (G+4 = 5 STOPS) having the following basic features: (Make: Mitsubishi / OTIS / KONE / Schindler / TK Elevator )
Type & Capacity: Passenger 13 Persons – 884 Kg. Speed: 1.50 Mtr/Sec Drive: AC Variable Voltage Variable Frequency Drive with Microprocessor based Simplex Collective Control Machine type & Location: MR - Gearless machine in machine room located directly above lift well. Travel considered: 17.5 mtrs. (Approx) Serving:Ground Floor to 4th Floor ( G,1,2, 3, 4) 5 Stops, 5 Levels, 5 Openings
Well Size: 2100 mm (W) X 1950 mm (D) or as per available well size Car Size (Clear Inside) approx.: 1200 mm Wide x 1400 mm Deep x 2200 mm Height Pit Depth: 1600 mm Head Room: 4500 mm (Aprox) Car Enclosure: SS Hairline + Silver Sky finish for front & back Panel and side panel with SS Honey ComB. Car door: 2 panel automatic center opening / side opening door with ACVF drive in Stainless steel Landing door: 2 panel automatic center opening door in Stainless Steel Silver Sky finish Handrail: Round handrail in Stainless Steel finish provided on rear wall of car Car suspended ceiling: Stainless Steel Silver Sky finish with Square LED for car lighting & full metal body Cross Flow Fan for air circulation Car Flooring: 20mm recess provided for granite/marble flooring (Shall be done by the OEM of Lift) No. of Entrances: One Location – Front. Car Entrance: Stainless steel Silver Sky finish with Frame All Landings: Stainless steel Silver Sky finish with Frame Clear Opening:as per standard Landing operating panel: Individual landing operating panel for each elevator
Power Supply: 415 volts, 3 phase, 50Hz, AC Auxiliary Power Supply: 220 volts, 1 phase, 50Hz, AC Light: Square LED Light Inside the Car Fan: Cross Flow Fan Indicators: Car & Landings: Direction & Position Indicator Display Audio System: Announcement of Car Position & provision to play song from inside the car
Other Features: Battery Operated Emergency Light & Alarm Call Registration LEDs OSG Electronic Switch Full Length Infra Red Light Curtain Door Safety Fireman Drive Load Weight Device Rescue Device KDS300 Round push Button. Lift Announcement Systems Full Height COP inside the CAR Intercom Telephonic Systems Car Door Lock systems
Supply installation testing & commissioning of New 15 Passenger-1020KG Elevator (G+4 = 5 STOPS) having the following basic features: (Make: Mitsubishi / OTIS / KONE / Schindler / TK Elevator )
Type & Capacity: Passenger 15 Persons – 1020 Kg. Speed: 1.50 Mtr/Sec Drive: AC Variable Voltage Variable Frequency Drive with Microprocessor based Simplex Collective Control Machine type & Location: MR - Gearless machine in machine room located directly above lift well. Travel considered: 17.5 mtrs. (Approx) Serving: Ground Floor to 4th Floor ( G,1,2, 3, 4) 5 Stops, 5 Levels, 5 Openings
Well Size: 2800 mm (W) X 1950 mm (D) or as per available well size Car Size (Clear Inside) approx.: 1200 mm Wide x 1400 mm Deep x 2200 mm Height Pit Depth: 1600 mm Head Room: 4500 mm Car Enclosure: SS Hairline + Silver Sky finish for front & back Panel and side panel with SS Honey ComB. Car door: 2 panel automatic center opening/side opening door with ACVF drive in Stainless steel Landing door: 2 panel automatic center opening door in Stainless Steel Silver Sky finish Handrail: Round handrail in Stainless Steel finish provided on rear wall of car Stretcher Impact Protection: Yes Car suspended ceiling: Stainless Steel Silver Sky finish with Square LED for car lighting & full metal body Cross Flow Fan for air circulation Car Flooring: 20mm recess provided for granite/marble flooring (Shall be done by the OEM of Lift) No. of Entrances: One Location – Front. Car Entrance: Stainless steel Silver Sky finish with Frame All Landings: Stainless steel Silver Sky finish with Frame Clear Opening: 800 mm Wide x 2000 mm High / as per standard Landing operating panel: Individual landing operating panel for each elevator
Power Supply: 415 volts, 3 phase, 50Hz, AC Auxiliary Power Supply: 220 volts, 1 phase, 50Hz, AC Light: Square LED Light Inside the Car Fan: Cross Flow Fan Indicators: Car & Landings: Direction & Position Indicator Display Audio System: Announcement of Car Position & provision to play song from inside the car
Other Features: Battery Operated Emergency Light & Alarm Call Registration LEDs OSG Electronic Switch Full Length Infra Red Light Curtain Door Safety Fireman Drive Load Weight Device Rescue Device KDS300 Round push Button. Lift Announcement Systems Full Height COP inside the CAR Intercom Telephonic Systems Car Door Lock systems
Additional Features: 1. ACVVVF closed loop drive 2. Alarm button in car operating panel with battery back-up 3. Automatic operation for car fan 4. Adjustable door open time 5. Anti-nuisance (empty car) 6. Anti-nuisance (car call cancellation at direction reversal) 7. Blower fan in car for ventilation 8. Braille on push buttons 9. Car call cancellation by double pressing floor button in car operation panel 10. Door open and door close buttons in car operating panel 11. Door closing retries
12. Door nudging 13. Emergency light 14. Full load by-pass 15. Home landing 16. Infra-red screen for car door 17. Intercom 18. Jammed landing operating panel call button by-pass 19. Motor overheat protection 20. Overload function with audio-visual indication in car operating panel 21. Phase failure and phase reversal protection 22. Automatic rescue device in case of power failure 23. Attendant control
24. Car arrival chime on car top 25. Red dot matrix scrolling display in car operating panel 26. Red dot matrix scrolling display in landing operating panel on All Floors 27. Fireman control 28. Fireman emergency return 29. BMS Compatibility 30. Independent operation (car VIP function) 31. Parking operation (key switch in landing operating panel) on main floor 32. Voice announcement unit in English language in car 33. RCC Socle for car and counter weight buffers 34. Auto light & fan switch OFF (POD) 35. 3-YEARS WARRANTY FROM THE DATE OF HANDING OVER
Scope of Work: 1. Supply installation, testing and commissioning of elevators at site as listed under Technical Specifications. 2. Material transportation, marine/inland Insurance, unloading of material at site 3. Obtaining Lift License (including all associated fees and expenses). 4. Site security (including security of partial, ongoing and Completed Work) 5. Store security (including on-site/off-site stores and stored Materials/Products within or outside storage area) 6. Provision and availability of safe, dry, weather-proof, lockable store (with sufficient lighting and two numbers three pin plug points) consisting of minimum 50 sqm area per elevator near the elevator shaft on ground or basement floor, for entire installation period. 7. Shifting of Materials/Products within the site (including shifting from existing store to another store or location on client’s request) except for the purpose of Installation of Products.
8. Provision of elevator shaft & pit/ escalator pit duly plastered, white washed, waterproofed, clean/ clear elevator pit/escalator pit, with shaft/pit dimensions as per approved General Arrangement Drawings (“GAD”) and within tolerance level and complete in all aspects without any further need of modification/rectification of shaft, pit, overhead, and entrance wall etc. 9. Provision of electrical power supply, including 230 V Single phase, 5A socket and 415 V three phase 50 HZ AC with earth leakage circuit breaker (ELCB) of required capacity as per GAD within 5 meters of each elevator/ escalator controller for installation, testing and commissioning, Effective double earthing from a separate (independent from other power equipment) earth pit exclusively for elevator(s)/escalator(s) Lightning arrestor and other electrical protective devices necessary to meet local regulatory/statutory requirement. Shaft lighting should be independent of main switch provided for control board.
10. Supply and erection of suitable scaffolding (as per approved GAD) inside elevator shaft/escalator pit for entire installation period and dismantling/removal of the same after completion of Works. Note: If in company’s’ scope, scaffolding shall be used for elevator installation works only and not for shaft preparation works etc. Also, the company may use scaffoldless method for installation works, at its own discretion. 11. Provision of minor builders’ works (details as per GAD) 12. Provision of dry and clean machine room with provision of cross ventilation (through exhaust fan), sufficient machine room lighting, lockable door (2m x 1m, outside opening type), with provision of rain protection guard on doors and windows, direct approach from terrace to machine room by a stairs or through rigid ladder with handrails and fall protection rails, trap door cover, fire extinguisher, smoke vent of suitable size in shaft covered with wire mesh.
13. Provision and fixing of support structures, hoisting beam/ hook fixed in the roof slab of the machine room, as required. 14a. Provision and fixing of separator channels for common shaft, if required. 14. Provision and fixing of screen between two adjacent shafts and or glass for glass shafts, if required. 15. Provision and maintenance of adequate light points/ lighting and lux level inside elevator shaft (including at each landing, machine room and the elevator pit)/ escalator pit. 16. Provision and availability of Flooring inside elevator car/cabin. 17. Supply of shaft reduction channels. 18. Installation of shaft reduction channels.
TK ELEVATOR INDIA PRIVATE LIMITED
M/S. S.B. CONSTRUCTION
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .