| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.2 LAccepted-AOC H NO B III 95 MOHALLA GHARTHOLI MISSION ROAD PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹37.0 L+₹43,568 (1.19%)Rejected-AOC 137 MODEL TOWN PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹37.5 L+₹92,649 (2.54%)Rejected-AOC DALHOUSIE ROAD BYE PASS CHOWK PATHANKOT 145001 PUNJAB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹38.0 L+₹1.4 L (3.88%)Rejected-AOC SAHEED UDHAM SINGH NAGAR THANDI KHUEE SUJANPUR PATHANKOT 145023 | PATHANKOT | PATHANKOT | PUNJAB | 145023 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹40.1 L+₹3.6 L (9.83%)Rejected-AOC BHANDARI NIWAS BHARAT NAGAR TEH DISTT PATHANKOT PIN 145023 | PATHANKOT | PATHANKOT | PUNJAB | 145023 | L5 | Rejected-AOC Rejected |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
6 Jul 2023, 6:00 pmClosed
Garrison Engineer(N) Mamun
Garrison Engineer(N) Mamun Pin-145001
SPL REPAIR TO BLDG NO P-26 (OR LIVING) OF ARTY BDE CAMP AND BLDG NO P-26 OF DIV CAMP AND REPAIR TO CHAJJAS, SEWERAGE LINE, ROOF TREATMENT, CONNECTING PATHS AT KV-03 STAFF QTRS UNDER AGE B/R-II OF GE(N) MAMUN
2023_MES_601423_1
GE(N)/M-15/2023-24
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer(N) Mamun
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer(N) Mamun
₹96,000
28 Aug 2023
6 Jun 2023
8 Jul 2023
6 Jun 2023
6 Jul 2023
24 Jun 2023
Amount
M&L for roof treatment (over existing non-accessible RCC roof slab / chajjah / canopy / parapet walls etc) to be executed through approved authorised applicator of manufacturer with following specification complete all as specified and directed :- (a) cleaning existing surface properly, (b) apply first coat of cold liquid Membrane STP Tarfelt LM or equivalent make having elongation not less then 200% conforming to ASTM-C-412 & having crack bridging of 8mm confirming to ASTM-C-836 with tensile strength conforming to ASTM-C-412 with no diluation of water & consumption @ 700gm per Sqm, (c) Lay Geotex of 45 GSM/ Fibre mesh simultaneously and paste it properly with overlap of 50mm, (d) Apply 2nd coat after 12 Hrs of first coat in opposite direction of first coat by Brush or Roller, (e) Applying two coats of U V Resistant Elastomeric Exterior Axcrylic Weather resistant water proof coating of Shalicryl-215 or equivalent approved make.
M&L for 20mm thick cement plaster in cement mortar 1:4 on concrete surface finished even and smooth mixed with with WPC as per manufacturer's instruction complete all as specified & directed. (WPC measured & paid separetaly)
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for, rubbish off the premises complete all as specified and directed
M&L for PCC 1:2:4 type B-0 ( using 12.5mm graded crushed stone aggregate) padding as roof , surface finished even and smooth without using extra cement complete all as specified and directed.
Supply only liquid water proofing compound
Dismantling of brick tile or terracing tiles with bedding layer of mortar etc and removal of rubbish beyond MOD land complete all as specified & directed.
M & L for brick tiles laid on cement mortar in CM 1:4 and joints grouted and flush pointed in CM(1:3) and mixed with 5 % of crude oil by wt. of cement
All as per item No 7 but except brick tiles.
S&F Box type Steel windows comprised of tubular frame and shutters made out of 1.25mm thick MS steel tube factory made with double side shutters wire gauged shutter & glass glazed shutter (wire mesh and glass panes shall be measured and paid separately) with side hung shutters with steel handle and steel peg stay dovetailed or welded including 2 Nos tower bolts 150mm long for each leaf and 8mm square bar grills at spacing as shown on drg welded to FI frame work, including other fittings, hinges, handles, tarred hold fasts, PCC blocks (1:2:4 type 12.50mm graded crushed stone aggregate) including two coats of synthetic enamel paint over a shop coat of red oxide primer etc. all as shown on drg No CEPZ /TD-354/09 sheet 1/3 to 3/3 complete all as specified and directed.
S&F 3mm thick frosted/pin head glass ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares any size in each pane complete all as specified and directed.
S&F Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with tinned tacks, or galvanized wire staples complete all as specified & directed.
Taking down cement plaster on brick walls or stone walls of any description etc including raking out joints, hacking for key, scrubbing down with water etc, rubbish off the premises complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 in two layers (10+5mm) on brick masonary of brick work surfaces finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for Rendering 10mm thick on fair faces of brick work, concrete sruface in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 5mm thick in CM 1:3 on concrete surface of ceiling, chajja etc, finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for breaking/dismentling, cleaning of loose concrete, replacement of corressive reinforcement, filling plain cement concrete 1:1.5:3 type A0 using 12.50mm graded crushed stone aggregate using approved bonding chamical (from Fosroc/STP/Sikka/ Dr. Fixit) at places like chajja, sunshades, roof projection, fascia, beams, columns etc including necessary scafolding, formwork etc complete all as specified and directed. Note :- Reinforcement steel shall be measured and paid for seperately.
Taking out peeled off plaster/ concrete surface, providing rust coating of PHRB-167/ rust free SHIELDOXY over old reinforcement and welded with new required reinforcemet, applying bonding adhesive chemical of STP/Fosroc over old concrete and M&L for plastering 10 mm thick in CM 1:3 in fascia / edging / ceiling of Chajjas, roof projections etc, making the edges in line, in true shape and finishing the surface without using extra cement including rubbish off the premises complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) n.exc 1.50 sqm each complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 Sqm and n.exc 4 Sqm each complete all as specified and directed.
S&F pressed steel frames for doors/windows of size 125x60mm (1.25mm thick MS sheet) with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, duly filling of cement concrete 1:3:6 type C-0 (using 12.50 mm graded crushed stone aggregate) to back of chowkhats, painted with a shop coat of red oxide primer complete all as specified and directed.
S&F 35mm thick factory made 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass or gauge etc (divided into squares with plain chamfered or rounded, mitred and rebated sash bars, any numbers), edges of framing plain chamfered or rounded, fitted with cut and mitered beads and fitted to chowkats for securing glass/gauge. Size of stiles rails and other parts as per clause 8.24 (a) of SSR Part-I complete all as specified & directed.
S&F 35mm thick factory made plain framed panelled shutters of 2nd class hard wood, two panels with lock rail and panel of 9mm thick BWP commercial ply. The size of rail and stile as per IS-1003 (Part-I), Kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F Solid PVC Door Frame of size 50 x 47 mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube, supplying & fixing in opening as per specification and drawing complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded wood grain printed PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and wood grain printed PVC sheet s for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of wood grain printed PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with 5mm thick & 15 mm wide PVC sheet beading used inside stiles and rails and decorative PVC beading of 10mm x 10mm (90 degree), and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing complete all as specified and directed.
M&L for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
S&F 100 mm long Butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and directed.
S&F aluminium anodized barrel tower bolts 150 mm of extruded section (as per sample) fixed complete all as specified and directed.
S&F 150 mm size aluminium alloy handles, febricated type extruded section (as per sample), complete all as specified and directed.
S&F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor Overall length of cover plate 150mm, fixed in floor complete all as specified & directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and jointed (joint free) in neat cement slurry and pointed in coloured cement laid over 15mm thick screed bed or bedding layer of mortar in CM 1:6 including dismantling floor, hearth or walls tilling and terrazo topping including cement mortar bedding (but not backing), rubish off the premises complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surface 450x300x7mm set and jointed (joint free) in neat cement slurry and pointed in white or coloured cement to match over 10mm thick screed bed or bedding layer of mortar in CM 1:4 complete all as specified and directed, Dismantling floor, hearth or walls tilling and terrazo topping including cement mortar bedding (but not backing), rubish off the premises complete all as specified and directed.
Taking up or down steel water tubing and connections including cleaning for refixing of pipe 15mm bore complete all as specified and directed.
All as per item No 32 but 20mm bore
S&F 15mm bore tubes medium grade galvanized ISI marked with all fittings, short pieces and fixed to walls, floor, ceiling etc complete all as specified and directed.
All as above item No 34 but fixing only complete all as specified and directed.
M&L for cutting chases, pinning in brick work, making good to facing where required, pointing in CM 1:3, cutting n.exc. 10cm in girth complete all as specified and directed.
S&F 20mm bore tubes medium grade galvanized ISI marked with all fittings, short pieces and fixed to walls, floor, ceiling etc complete all as specified and directed.
All as above item No 37 but fixing only.
S&F in repair 15mm bore dia angle valve / stop valve cast copper alloy chromium plated fancy type (as per sample) ISI marked with crutch or butter fly handles screwed down, screwed for iron pipe complete all as specified and directed.
S&F in repair 15mm bore dia concealed type angle valve / stop valve (as per sample) cast copper alloy chromium plated fancy type with long shank and cup ISI marked with crutch or butter fly handles screwed down, screwed for iron pipe of 15mm bore complete all as specified and directed.
S&F in repair 15mm bore dia Bib taps long nose, cast copper alloy, chromium plated fancy type ISI marked (as per sample) with crutch or butter fly handles, screwed down, screwed for iron pipe complete all as specified and directed.
S&F in repair towel rail, brass, CP 600 mm long 15mm dia pipe of 1mm thick complete all as specified and directed.
S&F in repair over head shower 125mm size for 15mm bore pipe, cast copper alloy chromium plated fixed in repairs complete all as specified & directed. Make - Jaquar , Marc and Johnson
S&F in repair vitreous china, squatting Pan 'Orissa' pattern 'white' size 580mm x 440mm white with integral footrest including provision of lean concrete bedding, connection to drain out pipe, flush pipe, flush pipe and anti syphonage pipe etc, making good to floor where required complete all as specified & directed.
S&F in repair Vitreous china wash down water closet pan pedestal pattern , white (excluding supply of flushing cistern and flush pipes, but including fixing thereof), including making connections to trap, and to flush pipe including plastic seat and cover with stainless steel or aluminised hinging device and fixed complete all as specified and directed.
S&F in repairs Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and directed.
S&F in repairs Vitreous china wash basin, white flat back, size 550 x 400 mm (as per sample), brackets, CP waste coupling and cutting for and pinning in ends of brackets or errecting stand including 32 mm dia waste pipe complete all as specified and directed.
S&F in repair PVC low level flushing cistern 10 ltr capacity, inlet and outlet connections, brackets, PVC flush pipe with bend 32 mm dia of suitable length including making necessary connections to water supply pipe line and jointing to WC complete all as specified and directed.
S&F in repair PVC connection 15 mm dia & length 450 mm with PTMT nuts complete all as specified and directed.
Taking down eaves gutters and rain water pipes (any size or pattern), including all fitting, head, shoes, bend, swan-nacks etc., including cleaning or refixing and removal complete all as specified & directed.
S&F PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints, fixed to walls having strength not less then 6kg/cm sq complete all as specified and directed.
S&F PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints, fixed to walls having strength not less then 6kg/cm sq complete all as specified and directed.
S&F PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors having strength not less then 6kg/cm sq complete all as specified and directed.
S&F PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors having strength not less then 6kg/cm sq complete all as specified and directed.
S&F PVC (SWR) 75mm bore vent cowl complete all as specified and directed.
S&F PVC (SWR) 110mm bore junction single, (Single T) equal or unequal, complete all as specified and directed.
S&F PVC (SWR) 75mm bore junction single, (Single T) equal or unequal, complete all as specified and directed.
S&F PVC (SWR) 110/75mm bore reducers, complete all as specified and directed.
S&F PVC (SWR) 110mm bore bends any radius , complete all as specified and directed.
S&F PVC (SWR) 75mm bore bends any radius with access door, complete all as specified and directed.
S&F PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75mm bore, complete all as specified and directed.
M&L for PCC 1:5:10 type E2 using 40mm graded crushed stone aggregate as in sunken floors portion including demolition of PCC & removal of rubbish complete all as specified and directed.
M&L for Rotational moulded polyethylene water storage tanks cylindrical vertical with closed top) two layers, Capacity 1000 litres, ISI Marked including all accessories, 20mm bore Ball brass valves, high pressure with polythene float and flynut complete, screwed down for iron pipe fixed complete, hoisted and fixed in position all as specified in SSR Part-I including dismantling of old tank complete all as specified and directed.
S&F in repair 20mm bore dia gun metal globe or gate valves (as per sample) with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed
M&L for preparation of new plastered surface of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for preparation of new plastered surface of walls and applying two coats of cement base paint over one coat of primer complete all as specified and directed.
M&L for preparation of new plastered surface of walls and applying two coats of oil bound distemper over a coat of chalk whiting complete all as specified and directed.
M&L for APP modified roof treatment over existing non-accessible RCC roof slab / chajjah / canopy / parapet walls to be executed through approved applicator of the membrane manufacturer with following specification etc complete all as specified and directed :- (a) Cleaning existing surface properly. (b) Applying oil bound bitumen primer @ 0.30 liter/Sqm manufacture by the same agency as that of APP having a density 0.87-0.89 Kg per liter at 25 degree centigrade on prepared surface. (c) Laying not less than 3mm thick APP modified water proofing membrane weighing not less than 3.60 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gsm using butane torch by torch application with 10cm side laps and 15cm end overlap of membrane. (d) Top of membrane shall be provide with solar reflective bituminous aluminum paint @ 0.1 Kg/Sqm or as prescribed by manufacture of membrane/ directed by Engr-in-charge.
Demolition of brick work or stone masonry built in cement mortar including all quoins arches, pillar etc but excluding ashlar facing , dressed stone work and precast concrete articles,and removal of debris out off the premises etc complete all as specified and directed.
M&L for Brick work with fly ash bricks (Old Size bricks) straight or curved on plan exc 6 mtr mean radius built in CM (1:6) complete all as specified & directed.
All as per Srl item No 71 but except bricks using old serviceable bricks.
M&L for 15mm thick cement plaster in CM 1:4 on brick masonary on other than fair faces of brick work, surfaces finished even and smooth without using extra cement complete all as specified and directed.
S&F Mild steel TMT bars bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified & directed.
M&L for 200 mm bore reinforced cement concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and directed.
Demolition and breaking up RCC drain pipes of upto 200mm bore and removal of rubbish complete all as specified and directed.
Excavating in trenches n exc 1.5m wide and n exc 1.5m depth for foundation etc or for shafts, well, cesspits, manholes, pier holes, etc n exc 10 sq m on plan and n exc 1.5m depth and getting out in any type of soil complete all as specified and directed.
Returning filling in, including spreading , levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
Removing excavated material to a distance n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
M&L for preparation of new plastered surface of external wall and chajjas, making surface smooth using sand paper, priming the surface with alkali resistance primer paint for external surface, applying two coats of cement base paint including curing complete all as specified & directed.
All as per item 81 but on old surfaces.
Taking down carefully unsv copper/aluminium point wiring (light/fan/socket or power) complete, including fixture and fittings such as switches, sockets, ceiling rose, lamp holders etc and making good disturbed surface of wall/floor with cement mortar and finishes to match existing surface.
M&L Point wiring with 1.5 Sq. mm (nominal area) FRLS PVC insulated and sheathed multistranded copper conductor cable 1100 Volts grade with proper colour coding and 1.5Sqmm PVC insulated unsheathed copper conductor multistranded cable( green colour) as earth lead drawn through and incl PVC rigid concealed conduit medium grade (ISI Marked) not less than 20mm dia and thickness not less than 1.5mm with all accessories incl CI/MS terminal box of adequate size having thickness not less than 1.6mm including 3mm thick hylam sheet including cutting chases on wall and making good the disturbed surface complete connection of cable for one light/fan point controlled by one switch.
All as per Ser item No 84 above but for one light point controlled by two 2way switches.
All as per Ser item No 84 above but for one 5/6 amp socket point on same board.
All as per Ser item No 84 above but for one 5/6 amp socket point on independent board.
All as per Srl item No 84 above but using 2.5Sqmm (nominal area) FRLS PVC insulated multistranded unsheathed copper conductor cable including 2.5 Sqmm FRLS PVC insulated and unsheathed copper conductor cable as earth conductor (green colour) connected to common earth dolly for one power point on independent board complete all as specified.
S & F switch piano flush button single pole one way 5/6 Amp AC 240 volts, all as specified.
S & F switch piano flush button single pole two way 5/6 Amp AC 240 volts, all as specified.
S&F socket outlet 2 in 1, 3pin, 5/6 Amps complete all as specified and directed.
S & F Socket outlet 2 in 1, 6 pin, 15/16 Amps, flush type, AC 240 volts all as specified.
S & F switch piano flush type, single pole 15/16 amps, one way, AC 240 volts all as specified.
M & L for ceiling rose, PVC/Polycarbonate, insulated body, surface Bakelite 65mm dia three terminals all as specified.
M&L for Lamp holder,fancy jumbo type, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified.
S&F 20W surface / wall mounted box type batten LED luminaire 4feet long, extruded PC housing with diffuser and integrated electronic driver with high efficiency long life, PF > 0.95, system luminous efficacy≥100 lumens/Watt operating voltage 140V-240V complete with all accessories internally prewired and including connecting up with suitable size flexible copper conductor cable from ceiling rose to connector of LED fitting complete all as specified.
S&F 10W wall mounted box type batten LED luminaire 2feet long, extruded PC housing with diffuser and integrated electronic driver with high efficiency long life, PF > 0.95, system luminous efficacy≥100 lumens/Watt operating voltage 140V-240V, complete with all accessories internally prewired and including connecting up with suitable size flexible copper conductor cable from ceiling rose to connector of LED fitting complete all as specified.
S & F in replacement SPN MCB DB 4 way sheet metal enclosures double door 230 V AC, 50 Hz AC with IP 43 and IK 09 rating having fully insulated copper busbar, neautral bar, earth bar and cable ties for cable management including polyuthrene gasket complete fixed flush in wall including cutting chases on wall for fixing of DB and making good disturbed surface of wall with cement mortar and finishes to match exisiting surface.
S&F MCB SP 240V, 50Hz, 10 KA, of rating 6 to 32 Amp using thimbles of required size complete all as specified and directed.
S&F MCB SPN 240V, 50Hz, 10 KA, of rating 32 Amp using thimbles of required size complete all as specified and directed.
S&F sub Main Wiring with two single core PVC insulated unsheathed multistranded flexible copper conductor cable of size 2x4 sqmm and one single core PVC insulated multistranded unsheathed flexible copper conductor 4 sqmm size (green colour) cable as earthing lead connecting to main earthing dolly drawn in and including non metallic concealed conduit medium grade with all accessories of dia not less than 20mm and 1.8mm thick incl cutting chases on wall and making good to disturbed surface of wall/floor with cement mortar and finishes to match existing surface all as specified. Note: 3 runs of copper conductor incl PVC conduit will be measured as one unit.
All as per item No 101 above but for size 6sqmm.
Deduct : Total amount of SCH 'A' SECTION-II (SCH OF CREDIT) Rs. 30,849.00 to be deducted from Schedule ‘A’ (BOQ) to arrive at the Contract Sum.
M/S DUGGAL CONSTRUCTION CO
WALIA ENTERPRISES
yash paul gupta
M/s GIrdhari Lal Rakesh Kumar
VIKRAM SINGH MANHAS
RD Engineers
M/S CHAMAN LAL GUPTA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .