Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.6 LAccepted-AOC 131 SHINGANAPUR ROAD KOLKI KOLKI SATARA MAHARASHTRA 415523 | SATARA | MAHARASHTRA | 415523 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹32.5 L+₹2.3 L (7.46%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹32.6 L+₹2.4 L (8.07%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹35.7 L+₹5.5 L (18.4%)Rejected-Finance | L4 | Rejected-Finance Other than lowest |
| Sl No | Description | Qty | Unit | PAWAN COOL CORPORATION L2 | M/s Hanspal Enterprises L3 | keerti trading corporation L4 | VISHAL TRADERS L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | M&L for servicing of window air conditioner 1/1.5 /2TR at various locations complete by cleaning/ filter/ condenser/ evaporator section with spraying water jet, and brushing, removing of dust/ dirt from air conditioner all over, check all electric connections, checking any leakage by applying soap solution on joints and liquid/ vapour lines properly. Cheking of functionally of spares of air conditioners and replacing the detective items supply under relevant item of schedule & rectifying the defects and put the air conditioners into operation complete all specified and directed by Engr-in-Charge. | 55 | Each Job | 325 ₹17,875 | 300 ₹16,500 | 1,200 ₹66,000 | 249 ₹13,695 Lowest |
| 1.10(Notes- (i)Spares shall me measured and paid saperately under relevent item of schedule (ii) As the nature of work is of daily maintanace of air conditioners contractor should deploy adequate trained two technicians with helpers as intimated by Engineer in charge to rectify the complaint within 48 hours of receipt of complaint failing which penalty of Rs 200 per complaint per Day till the rectiication shall be charged from the contractor (iii) Contractor should make own arrangement for transportation of Air conditioners from site to workshop. Note :- Contractor shall be maintane register for servicing of AC with date wise commencement & completion. | |||||||
| 2.00 | M&L for servicing of indoor and outdoor units of split type AC of capacity 1.5/2 TR at various locations complete by cleaning of filters, indoor cooling coil, condenser coil with sparying water and brushing, removing of dust, dirt from air condtioners all over heck all electric connections, checking any leakage by applying soap solution on joints and liquid/ vapour lines properly. Cheking of functionally of spares of air conditioners and replacing the detective items supply under relevant item of schedule & rectifying the defects and put the air conditioners into operation complete all specified and directed by Engr-in-Charge. | 150 | Each Job | 375 ₹56,250 | 300 ₹45,000 | 1,200 ₹1,80,000 | 249 ₹37,350 Lowest |
| 3.00 | All as per item no. 2 here in before but tower AC of capacity 3.5 TR | 4 | Each Job | 425 ₹1,700 Lowest | 900 ₹3,600 | 500 ₹2,000 | 499 ₹1,996 |
| 4.00 | Supply,fixing and replacement of Running capacitor 1.5 MFD Make :ASIAN/ELLYT/EPCOS | 30 | Each | 45 ₹1,350 | 40 ₹1,200 | 30 ₹900 | 19 ₹570 Lowest |
| 5.00 | Supply only Running capacitor 2.5 MFD Make :ASIAN/ELLYT/EPCOS | 40 | Each | 55 ₹2,200 | 50 ₹2,000 | 30 ₹1,200 | 29 ₹1,160 Lowest |
| 6.00 | Supply only Running capacitor 4 MFD Make :ASIAN/ELLYT/EPCOS | 40 | Each | 60 ₹2,400 | 70 ₹2,800 | 35 ₹1,400 Lowest | 39 ₹1,560 |
| 7.00 | Supply only Running capacitor 6 MFD Make :ASIAN/ELLYT/EPCOS | 30 | Each | 65 ₹1,950 | 60 ₹1,800 | 50 ₹1,500 | 49 ₹1,470 Lowest |
| 8.00 | Supply only Running capacitor 36 MFD Make :ASIAN/ELLYT/EPCOS | 50 | Each | 175 ₹8,750 Lowest | 300 ₹15,000 | 200 ₹10,000 | 289 ₹14,450 |
| 9.00 | Supply only Running capacitor 45+6 MFD Make :ASIAN/ELLYT/EPCOS | 60 | Each | 265 ₹15,900 | 390 ₹23,400 | 250 ₹15,000 | 219 ₹13,140 Lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
2 Feb 2026, 6:00 pmClosed
GE(AF) EM Chakeri
GE(AF) EM Chakeri Kanpur
REPAIR/ MAINT AND SERVICING OF SPLIT TYPE AND WINDOW TYPE AIR CONDITIONER AT ADM AND SEMI TECH AREA AND OF WATER COOLERS, REFRIGERATOR, DEEP FREEZER AND DESERT COOLERS AT AFS CHAKERI KANPUR
2026_MES_748225_1
8806/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Area under GE(AF) EM Chakeri
As per tender document
9 documents required · 9 mandatory
₹500
GE(AF)EM Chakeri
₹80,000
Yes
15 Apr 2026
13 Jan 2026
6 Feb 2026
13 Jan 2026
2 Feb 2026
27 Jan 2026
M&L for servicing of window air conditioner 1/1.5 /2TR at various locations complete by cleaning/ filter/ condenser/ evaporator section with spraying water jet, and brushing, removing of dust/ dirt from air conditioner all over, check all electric connections, checking any leakage by applying soap solution on joints and liquid/ vapour lines properly. Cheking of functionally of spares of air conditioners and replacing the detective items supply under relevant item of schedule & rectifying the defects and put the air conditioners into operation complete all specified and directed by Engr-in-Charge.
(Notes- (i)Spares shall me measured and paid saperately under relevent item of schedule (ii) As the nature of work is of daily maintanace of air conditioners contractor should deploy adequate trained two technicians with helpers as intimated by Engineer in charge to rectify the complaint within 48 hours of receipt of complaint failing which penalty of Rs 200 per complaint per Day till the rectiication shall be charged from the contractor (iii) Contractor should make own arrangement for transportation of Air conditioners from site to workshop. Note :- Contractor shall be maintane register for servicing of AC with date wise commencement & completion.
M&L for servicing of indoor and outdoor units of split type AC of capacity 1.5/2 TR at various locations complete by cleaning of filters, indoor cooling coil, condenser coil with sparying water and brushing, removing of dust, dirt from air condtioners all over heck all electric connections, checking any leakage by applying soap solution on joints and liquid/ vapour lines properly. Cheking of functionally of spares of air conditioners and replacing the detective items supply under relevant item of schedule & rectifying the defects and put the air conditioners into operation complete all specified and directed by Engr-in-Charge.
All as per item no. 2 here in before but tower AC of capacity 3.5 TR
Supply,fixing and replacement of Running capacitor 1.5 MFD Make :ASIAN/ELLYT/EPCOS
Supply only Running capacitor 2.5 MFD Make :ASIAN/ELLYT/EPCOS
Supply only Running capacitor 4 MFD Make :ASIAN/ELLYT/EPCOS
Supply only Running capacitor 6 MFD Make :ASIAN/ELLYT/EPCOS
Supply only Running capacitor 36 MFD Make :ASIAN/ELLYT/EPCOS
Supply only Running capacitor 45+6 MFD Make :ASIAN/ELLYT/EPCOS
Supply only Running capacitor 50+6 MFD Make :ASIAN/ELLYT/EPCOS
Supply only Running capacitor 55+6 MFD Make :ASIAN/ELLYT/EPCOS
Supply only starting relay 1.5/2.0 TR/3.5 TR Make: Asian/Epcos/renutrol
Supply only thermostate switch with knob suitable for window AC all as specified & directed by Enginner in Charge.
Supply only in replacement contactor relay for split/tower AC of capacity up to 3.5 TR AC, 415V, 50Hz, 3 Phase all as specified & directed by Enginner in Charge.
M & L for disconnecting of u/s PCB from the unit of split AC/ window AC transporting to Market for repair/ replacement of defective part required to make servicable & reinstalling with the unit and making connections complete all as per specified and directed by Engr-in-Charge.
M & L for disconnecting of u/s PCB from the unit of inverter type split AC/ window AC transporting to Market for repair/ replacement of defective part required to make servicable & reinstalling with the unit and making connections complete all as per specified and directed by Engr-in-Charge.
S & F replacement of MCB SP 240 Volt 32 Amp 10 KA capacity all as specified & directed by Enginner in Charge
S & F in replacement Metal clad socket industrial 2pin & earth plug of 20A, 230V complete suitable for AC Box all as specified & directed by Enginner in Charge. Make : Legrand/ABB/Havells
S & F in replacement Metal plug top industrial 2pin & earth plug of 20A, 230V complete suitable for AC Box all as specified & directed by Enginner in Charge. Make : Legrand/ABB/Havells
Supply only (NRV) suitable for window/split Ac of 1.5/2 TR all as specified & directed by Enginner in Charge
Supply,fixing and replacement of Flare nut 6/8'' all as specified and directed by Engr-in-Charge.
Supply,fixing and replacement of Flare nut 5/8'' all as specified and directed by Engr-in-Charge.
Supply,fixing and replacement of Flare nut 3/8'' all as specified and directed by Engr-in-Charge.
Supply,fixing and replacement of Flare nut 1/2'' all as specified and directed by Engr-in-Charge.
Supply,fixing and replacement of Flare nut 1/4'' all as specified and directed by Engr-in-Charge.
Supply,fixing and replacement of Dead nut 6/8'' all as specified and directed by Engr-in-Charge.
Supply,fixing and replacement of Dead nut 5/8'' all as specified and directed by Engr-in-Charge.
Supply,fixing and replacement of Dead nut 3/8'' all as specified and directed by Engr-in-Charge.
Supply,fixing and replacement of Dead nut 1/2'' all as specified and directed by Engr-in-Charge.
Supply,fixing and replacement of Dead nut 1/4'' all as specified and directed by Engr-in-Charge.
Supply,fixing and replacement of suction valve 6/8'' all as specified and directed by Engr-in-Charge.
Supply,fixing and replacement of suction valve 5/8'' all as specified and directed by Engr-in-Charge.
Supply,fixing and replacement of suction valve 1/2'' all as specified and directed by Engr-in-Charge.
Supply,fixing and replacement of suction valve 1/4'' all as specified and directed by Engr-in-Charge.
Supply,fixing and replacement of Discharge valve 3/8'' all as specified and directed by Engr-in-Charge.
Supply,fixing and replacement of Discharge valve 1/4'' all as specified and directed by Engr-in-Charge.
Supply only replacement OLP relay suitable for 1.5 TR/2.00 TR AC Make :ASIAN/EPCOS/RENUTROL
Supply only copper liquid line filter 3 way suitable for copper pipe of 3/8 dia for window/ split AC
Supply and fix in replacement Copper pipe 5/8 " outer dia all as specified and directed by Engr-in-Charge.
Supply and fix in replacement Copper pipe 3/8 " outer dia all as specified and directed by Engr-in-Charge.
Supply and fix in replacement only Copper pipe 1/2 " outer dia all as specified and directed by Engr-in-Charge.
Supply and fix in replacement Copper pipe 1/4 " outer dia all as specified and directed by Engr-in-Charge.
S & F in replacement copper pipe insulation of any size complete suitable for split /Tower AC all as specified and directed by Engr-in-Charge.
M&L for dismantaling, disconnecting u/s compressors from Split/window AC of capacity 1.5 TR and replacement with new HSCM compressor (rotary type) on mountings such as rubber pads, nut, bolt, wahers and breezing suction and discharge lines properly, making electrical connections, checking and leakage at joints and vaccuming the system all as specified and directed by Engr-in-Charge. Note:- Serial Number of compressor & its Make shall be recorded in MB
All as per item no. 44 but Rotary Compressor for 2.0 TR AC, 220V, Single Phase.
All as per item no. 44 but Reciprocating compressor for 1.5 TR AC 220 V.
All as per item no. 44 but Reciprocative compressor for 2.0 TR AC 220 V.
All as per item no. 44 Scroll compressor of capacity 3.5 TR AC, 415V,50Hz , Three phase
M & L transportaion of air conditioner from site to work shop for defecting leakage from the close circuit of window air conditioner 1/1.5/2.0 TR capacity, rectifying the leakage by breezing of copper rod using by butane gas flame, vaccuming the system after rectification of leak charging nitrozen and holding the pressure not less than 24 hours & refixing back to its original position at site all as specified and directed by Engr-in-Charge.(Note:- Cost of brazzing rod, butane gas cartridge and nitrogen shall be included in the quoted rates)
M & L for dismantling of indoor unit split Air conditionerof capacity 1.5/2 TR transporting from site to workshop for defecting leakage from the close circuit of split air conditioner of rectifying the leakage by breezing of copper rod using by butane gas flame, vaccuming the system after rectification of leak charging nitrozen and holding the pressure not less than 24 hours & refixing back to its original position at site all as specified and directed by Engr-in-Charge.(Note:- Cost of brazzing rod, butane gas cartridge and nitrogen shall be included in the quoted rates)
M & L for dismantling of outdoor unit split Air conditioner of capacity 1.5/2.0 TR transporting from site to workshop for defecting leakage from the close circuit of Split air conditioner of rectifying the leakage by breezing of copper rod using by butane gas flame, vaccuming the system after rectification of leak charging nitrozen and holding the pressure not less than 24 hours & refixing back to its original position at site all as specified and directed by Engr-in-Charge.(Note:- Cost of brazzing rod, butane gas cartridge and nitrogen shall be included in the quoted rates)
M & L for defecting leakage from the close circuit of Tower air conditioner of capacity 3.5 TR rectifying the leakage by breezing of copper rod using by butane gas flame, vaccuming the system after rectification of leak charging nitrozen and holding the pressure not less than 24 hours or as specified and directed by Engr-in-Charge & refixing back to its original position at site.
M & L for charging of refrigerent R-22 in window / split AC of capacity 1/1.5/2.0/3.5 TR capacity after detection and rectification of leakage under relevant item No. 35,36, 37 & 38 of schedule and testing Complete all as specified and directed by Engr-in-Charge.Make:-Mefron/Retron/Freon/Godrej
All as per item no. 53 but charging of refiregent R-32
All as per item No.53 but charging of refiregent R-410
Supply only refrigerent R-22 gas suitable for split/ window type air conditioner in empty cylinder at AGE E/M-III storeyard complete all as specified and directed. Note: (i) Empty cylinder will be provided by the department for filling up refrigerent. (ii) Refrigerent purchase voucher should be provided by the contractor. (iii) The refrigerent shall be taken on ledger charge with receipt voucher and issued as per requirement complete all as specified and directed.
All as per item No.56 but charging of refiregent R-32
All as per item No.56 but charging of refiregent R-410
M&L for disconnecting and dismentaling of blower/ condenser fan motor of window air conditioner of capacity 1.5/2.0 TR transporting for civil workshop and rewinding with super enamelled copper conducter wires of superior quality and assembling with the AC unit and testing and commisioning complete all as specitfied directed by Engr-in-Charge.
All as per item No.59 but motor of out door unit of split type air conditioner of capacity 1.5/2.0 TR
All as per item No.59 but motor of Tower AC 3.5 TR capacity
S&F in replacement of single phase electric motor AC of indoor unit capacity 1.5/2.0 TR split AC as per existing make and sample as per site requirement all as specified and directed by Engr-in-Charge.
S&F in replacement of single phase electric motor DC of indoor unit capacity 1.5/2.0 TR split AC as per existing make and sample as per site requirement all as specified and directed by Engr-in-Charge.
M & L for disconnecting and leak almunium condenser coil from split air conditioner of capacity 1.5/2.0 TR and supply & Fixing of copper tube condenser coil of suitable size as per sample and make and fixing with the outdoor unit of air conditioner vaccuming the system complete and commissioning after fixing complete all as specified and directed by Engr-in-Charge.
S&F replacement sheet metal enclosure, 32 Amp single pole and nutral with a two pin and earth plug socket complete metal clad board (industrial type with MCB 32 Amp fix properly all as directed by engr-in-charge. Make: ligrand/HPL/L&T
M & L for factory made ms angle iron stand of suitable size to mount outdoor unit of capacity 1.5/2.0 TR split AC complete all as specified and directed.
S & F Nylon stranded PVC flexible pipe Drain pipe of size 15 mm as per sample all as specified & directed by Engr-In-charge.
S & F in replacement PVC insulated & sheathed round multi stranded copper conductor 2.5 sq mm 3 core 1100 Volts graded. Make : Plaza / Havells / Finolex
Supply and fix in replacement fan blade for window AC of 1.5/2.0 TR capacity as per existing make and sample and as specified and directed by Engr-in-Charge.
S&F replacement of condenser fan blade of outdoor unit of split type air conditioner 1.5/2.0 TR capacity as per make & sample and all as specified and directed by Engrin Charge.
M&L for disconnecting of burnt PCB from the unit and supply and fixing of new PCB of window AC of cap of 1.5/2.0 TR of any make/model including testing and commitioning all as specified & directed by Engr-in-charge. Note :- Serial number of PCB and its Make shall be recorded in MB.
M&L for disconnecting of burnt PCB from the unit and supply and fixing of new PCB of split AC of cap of 1.5/2.0 TR of any make/model including testing and commitioning all as specified & directed by Engr-in-charge. Make:- OEM/Universal Note :- Serial number of new PCB alongwith its Make shall be recorded in MB.
M&L for disconnecting of burnt PCB from the unit and supply and fixing of new PCB of inverter type split AC (Indoor and outdoor) of cap of 1.5/2.0 TR of any make/model including testing and commitioning all as specified & directed by Engr-in-charge. Make:- OEM/Universal. Note:-Serial number of new PCB alongwith its Make shall be recorded in MB.
M&L for disconnecting of burnt PCB from the unit and supply and fixing of new PCB of Tower AC of cap of 3.5 TR of any make/model including testing and commitioning all as specified & directed by Engr-in-charge. OEM/Universal Note:-Serial number of new PCB alongwith its Make shall be recorded in MB.
S&F in replacement of condenser fan motor including mounting base, rubber, clips, as per existing make and soft length in split type AC of 1.5/2.0 TR capacity complete all as specified and directed.
S&F swing motor any type, split/ window type AC of 1.5/2.0 TR capacity complete all as specified and directed.
M & L for rewiding of burnt transformer of voltage stablizer of capacity 5 KVA with super enameled copper conducter winding wire and assembling with the stablizer complete all as specified and directed by Engr-in-Charge.
S & F in Repair/Replacement of relay 25/30 AMPS 24 volt make and capacity of 5 KVA voltage stabilizer complete all as specified & directed.
S & F in Replacement of main PCB with high and low voltage cut off PCB suitable for 5 KVA voltage stabilizer suitable making for existing all as specified & directed.
S & F window AC kit for 1.5 TR ( with compressor) complete all as specified & directed. Make:- Voltas, LG & Carrier,
Shifting of existing split type A/C of any capacity from one location to another location complete pumping down refrigerant gas into compressor including disconnecting electrical/ gas connections and making good disturbed surface in CM (1:4) with existing one and its installation by making necessary electric connection incl brazing and refixing complete all as directed.
Supply,fixing and replacement of of Timer tower AC complete all as specified & directed.
Supply,fixing and replacement of New remote as per OEM alongwith its suitable battrtery complete all as specified & directed.
Supply,fixing and replacement of coling coil senser complete all as specified & directed.
Supply,fixing and replacement of remote battery complete all as specified & directed.
M & L for Disconnecting water cooler of any size from main power and taking out for carrying out necessary repair/service/maintanance to check serviceability of compressors, fan motor , capacitor,thermostates, switches, gas leackage , push taps,fan blades,relays,over load protectors, condensor coils and any otyher spares required to make the water cooler functionaland fixing in origional / existing position complete all as specified and directed.
S & F in replacement Push cock, of brass chromium plated, 15 mm bore, complete all as specified.
S & F in replacement 15 mm bore PTMT float valve assembly with PVC float for water cooler complete all as specified and directed.
S & F in replacement combination relay unit complete suitable for water cooler 40/80 litre capacity complete all as specified and directed. Make: RANUTROL/ INDFOS/ KIRLOSKAR/ SRI RAM/HI TECH.
S & F in replacement combination relay unit complete suitable for water cooler 60/120 litre capacity complete all as specified and directed. Make: RANUTROL/ INDFOS/ KIRLOSKAR/ SRI RAM/HI TECH.
S & F in replacement combination relay unit complete suitable for water cooler 80/150 litre capacity complete all as specified and directed. Make: RANUTROL/ INDFOS/ KIRLOSKAR/ SRI RAM/HI TECH.
S & F in replacement over load protector suitable for water cooler complete all as specified and directed. Make: SHRIRAM/ RANUTROL/ KIRLOSKAR/HI TECH.
S & F in replacement copper condenser coil suitable for water cooler 40/ 80 litre capacity as per existing size complete all as specified and directed.
S & F in replacement copper condenser coil suitable for water cooler60/120 litre capacity as per existing size complete all as specified and directed.
S & F in replacement copper condenser coil suitable for water cooler 80/150 litre capacity as per existing size complete all as specified and directed.
S & F in replacement thermostat switch suitable for water cooler including knob plate and screw complete all as specified and directed. Make: INDFOS/RANUTROL/ SRIRRAM/USHA/HI TECH.
S & F in replacement condenser fan motor not less than 1/5 HP or as required complete suitable for water cooler complete all as specified and directed. Make: AMERICAN UNIVERSAL/USHA/AIR MASTER/COOLER MASTER.
Disconnecting old defective burnt sealed compressor unit of water cooler of capacity 40/80 Ltrs and replacement of same with new sealed compressor unit as per sample and including soldering of copper pipes, foundation rubber bushes, nut bolts cleaning the refrigerant system complete all as specified and directeded by Engr in charge, Note:- Serial number of compressor and its make shall be recorded in MB
Disconnecting old defective burnt sealed compressor unit of water cooler of capacity 60/120 and replacement of same with new sealed compressor unit as per sample and including soldering of copper pipes, foundation rubber bushes, nut bolts cleaning the refrigerant system complete all as specified and directeded by Engr in charge, Note:- Serial number of compressor and its make shall be recorded in MB
Disconnecting old defective burnt sealed compressor unit of water cooler of capacity 80/150 and replacement of same with new sealed compressor unit as per sample and including soldering of copper pipes, foundation rubber bushes, nut bolts cleaning the refrigerant system complete all as specified and directeded by Engr in charge, Note:- Serial number of compressor and its make shall be reeorded in MB
Preparation of old painted metal surfaces of water cooler by applying two coats spray painting of synthetic enamel paint ( colour as approved ) over outside metal body of water cooler of any make after removal of all dust and all foreign matter with the help of sand paper and rubbing with cleaning compound complete all as specified and directed by Engr in charge.
S & F in replacement fan blade of blower motor of water cooler suitable for any make and capacity complete all as specified and directed.
Testing of water cooler vacuumising properly and rectification of leakage in entire system and making the gas system leak proof by brazing/welding charging of refrigerent R-22 to the entire satisfaction of Engineer-in-Charge saperate items.
M & L for factory made ms angle moter stand of suitable size to mount of water cooler capacity of any size and including two coat of synthetic enamel paint and a coat of red oxide primer complete all as specified and directed.
M & L for disconnecting refrigerator from main power to carry out necessary servicing and checkups to maintain efficient working throughout the season/year by checking, cleaning all parts all as directed by Engg-in-charge
S & F in replacement freezer of refrigerator of cap upto 165 to 190 Ltr ltr including shouldering to copper pipes etc complete as directed.
S & F in replacement freezer of refrigerator of capacity 290 litres including shouldering to copper pipes etc charging of refrigerant complete as directed.
Disconnecting old defective burnt sealed compressor unit of Refrigerator 165 Liters capacity of any make and replacement of same with new sealed compressor unit including soldering of copper pipes, foundation rubber bushes, nuts bolts, cleaning the refrigerant system and testing complete all as specified and directed. Make: KIRLOSKAR/ KELVINATOR/ GODREJ/ WHIRLPOOL/ LG. Note :- Serial number of compressor and its Make shall be recorded in MB.
All as per Srl item No-108 here-in-before but capacity 190 litres.
All as per Srl item No-108 here-in-before but capacity 310 litres.
S & F in replacement starting relay assembly suitable for refrigerator up to 310 litres capacity complete all as specified and directed. Make: RANUTROL/ INDFOS/HI TECH.
S & F in replacement thermostat switch with defrosting arrangement suitable for Refrigerator 165/190/290/310 litres capacity including knob plate and screw complete all as specified and directed. Make: INDFOS/ RANUTROL/ HONEY WELL/HI TECH.
Cleaning the gas system along with rectification of leakage in the system of 165/190/290/310 litres capacity refrigerator and charging of refrigerent 134A complete all as specified and directed.
S & F in replacement DC freezer fan motor of refrigerator suitable for any make and capacity complete all as specified and directed.
M & L for disconnecting Deep freezer from main power to carry out necessary servicing and checkups to maintain efficient working throughout the season/year by checking, cleaning all parts all as directed by Engr-in-charge
Disconnecting old defective burnt sealed compressor unit of Deep freezer 320 Liters capacity of any make and replacement of same with new sealed compressor unit including soldering of copper pipes, foundation rubber bushes, nuts bolts, cleaning the refrigerant system and charging of refrigerant and testing complete all as specified and directed. Make: KIRLOSKAR/ KELVINATOR/ GODREJ/WHIRLPOOL/LG. Note :- Serial number of compressor and its Make shall be recorded in MB.
All as per Srl item No 116 here-in-before but capacity 425 litres.
All as per Srl item No 116 here-in-before but capacity 500 litres.
S & F in replacement starting relay assembly suitable for Deep freezer up to 500 litres capacity complete all as specified and directed. Make: RANUTROL/ INDFOS/HI TECH.
S & F in replacement thermostat switch with defrosting arrangement suitable for Deep freezer up to 500 capacity including knob plate and screw complete all as specified and directed. Make: INDFOS/ RANUTROL/ HONEY WELL/HI TECH.
S & F in replacement over load protector suitable for deep freezer complete all as specified and directed. Make: SHRIRAM/ RANUTROL/ KIRLOSKAR/HI TECH.
S & F in replacement condenser fan motor not less than 12 watt or as required complete suitable for deep freezer complete all as specified and directed. Make: AMERICAN UNIVERSAL/USHA/AIR MASTER/ COOLER MASTER.
Cleaning the gas system with CTC vacuum pump and charging the Deep freezer R-134A with antimoist substance and filter along with rectification of leakage in the system of up to 500 litres capacity Deep freezer and charging of refrgerent R-290 complete all as specified and directed.
M & L for Disconnecting Industrial cooler from main power and taking out for carrying out necessary repair/service/maintanance to check serviceability of water pump, fan motor , capacitor, switches, cooler body , water distribution pipes from the desert cooler, removing existing paint/treatment completely preparing the surface and applying externally two coats of synthetic enamel spray paint( as approved) over a coat of red oxide primer (shutters shall be painted all-round i.e. externally internally with one coat of synthetic enamel spray paint over a coat of red oxide primer) and painting cooler body internally with one coat of bituminous paint and refixing only serviceable motor, pump, PVC pipe, distributor and shutters in existing position complete all as specified and directed.
M & L for Disconnecting desert cooler from main power and taking out for carrying out necessary repair/service/ maintanance to check serviceability of water pump, fan 2.motor , capacitor, switches, cooler body , water distribution pipes from the desert cooler, removing existing paint/treatment completely preparing the surface and applying externally two coats of synthetic enamel spray paint( as approved) over a coat of red oxide primer (shutters shall be painted all-round i.e. externally internally with one coat of synthetic enamel spray paint over a coat of red oxide primer) and painting cooler body internally with one coat of bituminous paint and refixing only serviceable motor, pump, PVC pipe, distributor and shutters in existing position complete all as specified and directed.
M& L for rewinding fan motor of Industerial cooler with suitable size of super enameled copper wire including replacement of bush, insulating material, greasing, testing and refixing complete after repair all as specified and directed.
M & L for rewinding fan motor of desert cooler with suitable size of super enameled copper wire including replacement of bush, insulating material, greasing, testing and refixing complete after repair all as specified and directed.
S & F PVC flexible tubing , distributor and elbows and providing PVC flexible tubing distributor and elbows for desert cooler complete all as specified and directed.
S & F in replacement submersible pump of desert cooler single phase AC, 230 Volts, 50 Hz including necessary connection and testing complete all as specified and directed. Make: POLAR/KHAITAN/GEC.
S & F in replacement submersible pump of industrial cooler single phase AC, 230 Volts, 50 Hz including necessary connection and testing complete all as specified and directed. Make: POLAR/KHAITAN/GEC.
S & F in replacement PVC sheathed 3 core cable with copper conductor size 23/0.0076 for Desert cooler complete all as specified and directed. Make: FINOLEX/PLAZA/HAVELLS.
S & F in replacement new wooden wool dry pad of suitable size as required for desert cooler of best quality as approved by GE/Engg-in-charge , complete all as specified and directed.
S & F in replacement 3 Pin Plug top 5A, 240 Volt. Make : Havells /Anchor / Philips
All as per item No 134 but 3 pin plug top 15A, 240Volt -ditto-
S & F in replacement Piano type switch one way 5A, 240 V. Make : Anchor / Cona /Philips.
S & F in replacement Running Capacitor 4 MFD, 240 Volt AC. Make : Asian/Ellyt/Epcos
S & F in replacement Running Capacitor 6 MFD, 240 Volt AC. Make : Asian/Ellyt/Epcos
S & F in replacement Running Capacitor 8 MFD, 240 Volt AC. Make : Asian/Ellyt/Epcos
S & F in replacement Running capacitor 36 MFD 240 V. Make : EPCOSS/Asian/Ellyt
S & F in replacement Starting relay suitable for 1 TR Make : Renutrol/EPCOS/KELTRON
S & F in replacement Metal clad top industrial 2pin & earth plug top 20A, 230V complete suitable for AC Box. Make :Legrand/ ABB/Schneider
S & F in replacement Metal clad socket industrial 2pin & earth plug socket 20A, 230V complete suitable for AC Box. Make : Legrand/ ABB/Schneider
S & F in replacement MCB SP 20 amp 10 KA 240 volt capacity having C-curve characteristics. Make :Legrand / ABB/ HAVELLS
Supply and replace Cable flexible multistranded copper conductor PVC insulated sheathed 1.5 sqmm 3 core. Make : Havells/Plaza/Polycab
Supply and replace Cable flexible multistranded copper conductor PVC insulated sheathed 2.5 sqmm 3 core. Make : Havells/Plaza/Polycab
S & F in replacement NRV suitable for any make and capacity complete all as specified and directed.
M & L for servicing of water Dispenser of any make & capacity and carrying out repair as mentioned in respective items of Sch 'A' including transporting back after repair &, fixing at site, reconnecting electrical connections, testing & commissioning all as specified and directed. Note : Replacement of spare parts shall be measured and paid separately under relevant item of Sch 'A' and fixing and taking out is deemed to be included under this item.
Supply and replace PVC tap with capsten heads, down high pressure, with long screwed shanks and fly-nuts, screwed for PVC pipe and fixed. Make : Jaguar / Zenith
S & F in replacement of HSCM (rotary, single phase, 220V, 50 Hz) compressor suitable for water dispensor complete all as specified & directed by Engr in charge.
Testing of water dispenser vacuumising properly and rectification of leakage in entire system and making the gas system leak proof by brazing/welding to the entire satisfaction of Engineer-in-Charge saperate items.
S & F in replacement, for socket outlet 3 pin, 16 Amps flush type white finish complete all as specified. Make : Cona/Havells/Anchor
S & F in replacement, for socket outlet 3 pin, 6 Amps flush type white finish complete all as specified. Make : Cona/Havells/Anchor
S & F for GI Tube 15 mm dia, medium grade',galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified.
S & F for GI Tube 20 mm dia, medium grade',galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified.
S & F for GI stop/gate valves 15 mm dia,cast copper alloy screwed down, high pressure with clutch or butterfly handle screwed both ends for iron pipe or for union for fixed complete all as specified.
S & F for GI stop/gate valves 20 mm dia,cast copper alloy screwed down, high pressure with clutch or butterfly handle screwed both ends for iron pipe or for union for fixed complete all as specified.
stage.html
html • 0.05 MB
technical_837913.pdf
techsummary_837913.pdf
finance_837913.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.06 MB
BOQ_837913.xls
BOQ • 0.54 MB
8806E8_Tender_1.pdf
Tender Documents • 0.75 MB
Workdetails.pdf
Additional Documents • 0.09 MB
8806E8_CreditSchdule_1.pdf
Additional Documents • 0.21 MB
Tender_Acceptance_Letter.pdf
Additional Documents • 0.08 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .