Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance C 5 156 YAMUNA VIHAR EAST DELHI DELHI 110053 | NORTH EAST DELHI | DELHI | 110053 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 1 GANESH DARSHAN ADV SURVE MARG SANDHURST ROAD W MUMBAI 9 | MUMBAI | MAHARASHTRA | Admitted-Finance |
Tender Value
₹40.3 L
EMD Value
₹80,624
Closing Date
3 Jan 2023, 3:00 pmClosed
SM ( E ) Z4
1st floor, TE Bldg Goregaon, SV road, Goregaon West, Mumbai-400104
As per NIT
2022_MTNL_730601_1
SM (E)Z4/NIT/22-23/24
Open Tender
Electrical Works
Works
180 days
Zone -4
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Accounts Officer (CASH-BW), MTNL
₹80,624
5 Jan 2023
21 Dec 2022
4 Jan 2023
21 Dec 2022
3 Jan 2023
21 Dec 2022
Supply, Installation on existing foundation/platform/stand/frame, testing and commissioning of following rating microprocessor controlled package type air-cooled air-conditioning units with two independent refrigerant circuits and two compressors of equal rating, all other components & controls, interlocking, electrical accessories, indoor & outdoor units, various motors, coils, filters, microprocessor controller having provision to communicate with sequential controller, initial charge of oil & refrigerant as per detailed specifications attached etc. complete as required. The Air-conditioning unit shall be suitable for operation on 415V+/-10%, 50Hz, Three phase AC supply. ( This item includes pressure testing, vaccumazation &necessary gas charging) NOTE: 1. If any a.c. unit of rating higher than that mentioned above is offered by the firm which meets the prescribed technical specifications shall be accepted by the department without any extra charges. 2. In case of replacement of existing AC plant/ AC units, dismantling of all components of existing air cooled AC units along with associated copper piping, ducting, electrical cables and panels, foundations MS works for indoor and outdoor units and all other associated components as per site requirement including cutting, handling and stacking at required place in the premises of the same building and handing-over to the department is included in the above item for which nothing extra shall be paid by the department. 10TR Top Feed
Supply, Installation on existing foundation/platform/stand/frame, testing and commissioning of following rated microprocessor controlled air-cooled air-conditioning units with all components, controls, interlocking, electrical accessories including indoor & outdoor units, various motors, coils, filters, controller as per detailed technical specifications attached etc. complete as required. The Air-conditioning unit shall be suitable for operation on 415V+/-10%, 50Hz, Three phase AC supply. ( This item includes pressure testing, vaccumazation &necessary gas charging) Note: 1. If any a.c. unit of rating higher than that mentioned above is offered by the firm which meets the prescribed technical specifications shall be accepted by the department without any extra charges. 2. In case of replacement of existing AC plant/ AC units, dismantling of all components of existing air cooled AC units along with associated copper piping, ducting, electrical cables and panels, foundations MS works for indoor and outdoor units and all other associated components as per site requirement including cutting, handling and stacking at required place in the premises of the same building and handing-over to the department is included in the above item for which nothing extra shall be paid by the department. 5.5TR ductable A C unit
Providing and fixing of following sizes of copper refrigerant piping (soft annealed/hard drawn) with/without class 'O' tubular insulation and all accessories i/c cutting, bending, jointing, brazing etc. for refrigerant circuits of air-conditioning units, on existing surface complete as per specifications attached.
a) 7/8" without tubular nitrile rubber insulation
b) 5/8" without tubular nitrile rubber insulation
c) 7/8" with tubular nitrile rubber insulation
Providing and fixing factory fabricated/ site-fabricated GSS ducting i/c plenum of following sheet thickness, guide vanes i/c minor civil works making opening in the walls/partitions/floors and subsequent repairs etc. complete as per specifications and site requirement.
a) 0.63mm (24 gauge)
b) 0.80mm (22 gauge)
c) 1.00 mm (20 gauge)
Supply and installation of fresh air package suitable for following CFM provided with coarse filter having efficiency of 90% down to 20 microns, EU-2 type and fine filters for outside air having efficiency of 99.9 % for dust particles down to 5 microns, EU-5 type, mounted on a suitable frame along with necessary dry fabric synthetic type cleanable pre-filters, necessary sheet metal louvers/grills with volume control damper, minor civil works including making opening in the wall and subsequent repairs etc. compete as per specification. Necessary booster fans suitable for operation on 230 (+/- 5%) volts single phase 50 Hz A.C. Supply shall be provide to overcome the static pressure of fine filters as required. a) 1200 CFM
Providing and fixing 25mm thick, 24kg/m3 resin bonded glass wool insulation wrapped in hessian base vapor barrier covered with suitable gauge Al. sheet for supply air distribution system including frame work, etc. as per detailed specifications.
Providing and fixing acoustic insulation with 25mm thick 24 kg/ mtr3 fiber glass board covered with tissue paper of fiber glass and 28 SWG perforated factory laminated Al. sheet including frame work etc. complete as required.
Providing/making & fixing canvass connection made out of fire-resistant canvas cloth and GI frame of size suitable for package/ductable a.c. unit etc. complete as required.
Supplying and fixing of PVC insulated PVC sheathed copper conductor armored cables of following sizes on the existing M.S. trays/walls with saddles, screws etc i/c 2 nos. 8 SWG GI wire for loop earthing and end terminations of cables with glands etc. as required.
a) 4 x 10 sq. mm (For AC package unit)
b) 4 x 1.5sq. mm (For FA fan & condensers)
c) 3x2.5sq. Mm
d) 4 x 6 Sq. mm
Supplying and fixing following PVC insulated PVC sheathed copper conductor multi core armored cable for control wiring on existing tray/ surface of wall as req.
a) 2 x 1.5 Sq.mm.
b) 4 x 1.5 Sq.mm
c) 10 x 1.5 Sq.mm
Providing plumbing work for humidification circuits and drainage requirements including supply of cPVC/uPVC pipes, pipe fittings such as bends, reducers, elbows, tees, unions, flanges etc. for water supply/drain connection of various components of the system.
a) 38mm dia (NB)
b) 25mm dia (NB)
Supply, Installation, Testing and commissioning of audio visual annunciation prewired panel complete with required control accessories like relays, contactors and lamps, switches, fuses, wires, ferrules, connectors and proportional sheet metal work as per site requirement with each set consisting of required number of indications, suitable for package/ductable AC plants suitable up-to 3 no. of AC units complete as required. a) up-to 3 no. of AC units complete as required.
Supplying, Laying & fixing of following earthing material including fixing of hardware complete as required. 8 SWG G I wire
Providing & fixing cable tray, M.S structure for cables / refrigeration pipes / indoor units /outdoor units etc. fabricated out of M.S Channels/ Angles/ Flats/mesh i/c cutting, welding, painting, drilling holes, fixing on existing surface etc complete as required.
a) 150mm wide M.S. slotted angle cable tray
b) 300mm wide M.S. slotted angle cable tray
c) M.S. flat/Angle iron/Channel/Tee/I -section
d) Pdg. & fixing MS frame(stand type) for outdoor A C unit complete as reqd..
e) Pdg. & fixing MS frame/suspender for indoor A C unit complete as reqd.
Pressure testing with nitrogen pressure standing for at least 8hr vacuuming & commissioning with refrigerant of following A.c unit complete as reqd. 10TR PAC Unit
Supplying and filling refrigerant suitable for top-up in various AC units
Supply & fixing of following type of damper of size upto 5sq.ft. Made out of 18 gauge CRC/G I sheet used as fire damper, supply air damper or return air damper in main duct or branch duct or in return air path for package/ ductable AC indoor units as per site requirement. i/c nut bolt, gasket etc. as required. Volume control damper
S/F 11 watt LED ( Higher wattage) portable emergency light complete with maintenance free rechargeable battery suitable for 6 hours back up with inbuilt charger and extension lead with 5 Amp top etc complete as reqd.
S/L 6mm thick ISI marked rubber matting suitable for 11 KV grade supply as per site requirements.
Providing PCC water barrier with 1:2:4 cement concrete of required size i/c plastering, centering, providing suitable size angle iron etc. complete as required. (Angle iron shall be measured in item no.14-C)
Pdg. & fixing sequential controller system in a metal enclosure operating on 220V, single phase A C supply for controlling upto 7 number A.C. units in such a way that only designated number of A.C. units out of the seven A.C. Units will operate at a time for a fixed period of time keeping the other units in standby mode and there-after next A.C. unit start operating switching the earlier unit(s) in standby mode and so on i/c making closed loop system in such a way that in case of faults in one or more AC units, the standby unit transits to operational mode thereby operating the entire AC plant to maintain the temperature of the conditioned area. The sequential controller should be compatible to communicate with the main microprocessor controllers of the AC units. All necessary wiring between the sequential controller and the A.C. units is also included in the item.
SPEEDFROST SERVICES PVT LTD
M/s Om Vaishnav Technocrates
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .