Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹4.6 LAdmitted-Finance | L1 | Admitted-Finance | ||
| 2 | L2₹4.6 L+₹4,700.71 (1.02%)Admitted-Finance | L2 | Admitted-Finance | ||
| 3 | L3₹4.7 L+₹5,208.38 (1.13%)Admitted-Finance | L3 | Admitted-Finance |
Tender Value
₹4.7 L
EMD Value
₹9,400
Closing Date
5 Feb 2026, 4:00 pmClosed
Executive Engineer, Projects Div. JMC
Town Hall, JMC
Repair works at Death and Birth Section, Block A of Town Hall, JMC (Smart offices)
2026_HAUDD_300689_1
e-NIT No 51(P) of 2025-26 of Projects Div. JMC
Open Tender
Civil Works
Percentage
120 days
Jammu
Please refer Tender documents.
2 documents required · 2 mandatory
₹600
Yes
Executive Engineer, Projects Div. JMC
₹9,400
Yes
7 Feb 2026
15 Jan 2026
6 Feb 2026
15 Jan 2026
5 Feb 2026
15 Jan 2026
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.1 mm thick
Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm)
Providing and applying integral crystalline (dry shake) of hydrophilic in nature for waterproofing treatment to the RCC structures like basement raft, foundation slab, sewage & water treatment plant slab, warehouses floor, parking structures and water tank base slab etc. sprinkled @0.60kg per sqm or higher as recommended by the manufacturer’s specification over the lean concrete of above cited structures. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 85%, compared control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline dry shake shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
Providing, fixing and installing of 18-20W surface Batten LED lighter, 6500K colour temperature, maximum system wattage of 20W , useful life of 50000 Hrs (Complete LM 80 test report for LED should be submitted) , isolated type, multistage Constant Current Constant Voltage topology driver suitable to operate in input voltage range of 150V to 270V ( nominal rated voltage – 240V) with minimum 2KV surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less that 10% should be integral to the luminaire complete with all accessories required with lamps.Wipro Cat. No LL20-281-XXX-65AL1/Tisva RAY SQ PRO LED BATTEN FL1862T5R 18W 65K/ Philips : BN308C LED40S-6500 L120 PSU WH/ Trilux:TRL-X F OTA 4000-857 ET or equivalent. The rate quoted is for inclusive of wiring of 2x1.5 sqmm, modular switch, modular plate, modular box etc all complete fittings for switching on and off of the fixture. Each fixtures to be controlled by 1 no. 5 amp. switch
Hiring of Plumber for management of installed Sanitary and Plumbing works De-Clogging of existing pipes and propoer flushing of jalis and other pipes to ascertain stoppage free working of all infrastructure.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work-exposed on wall, including fixing the pipe with clamps at 1.00 meter spacing 15mm nominal outer dia pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work-exposed on wall, including fixing the pipe with clamps at 1.00 meter spacing 20mm nominal outer dia pipes.
Providing, jointing, testing and fixing UPVC Soil, Waste & Vent system conforming to IS : 13592 - Type B and UPVC fittings (moulded as well as fabricated) like bends, tees, Y-tees, crosses, boss connections, access pieces, saddle pieces, cleanouts, adaptors for connections to other materials, plugs, reducers, cowls, offSet and other specials. Jointing shall be done with pushfit EPDM ring jointing technique in general. Solvent cement joints may be provided for fittings and specials which are not manufactured with pushfit rubber joints. Pipes may be laid / fixed in sunken floors, under slung from ceiling. The pipes laid in sunken floor shall be encased with 75 mm thick cement concrete (1:2:4) all around. The installation shall be complete in all respects including cutting chases / holes in walls, slabs and making good the same as per specifications. 110 mm dia
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.72 MB
BOQ_975386.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .