| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.9 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹4.3 L+₹40,236.73 (10.2%)Rejected-Finance 1018 DR MUKHARJEE NAGAR DELHI 09 | 2 | Rejected-Finance L2 | |
| 3 | 3₹4.4 L+₹42,600.82 (10.8%)Rejected-Finance | 3 | Rejected-Finance L3 |
Tender Value
₹4.7 L
EMD Value
₹9,456
Closing Date
9 Mar 2026, 11:00 amClosed
Ex. ENGINEER (ELECT)/CSPZ
OFFICE OF THE EX. ENGINEER (ELECT)/CSPZ UNDER GROUND CAR PARKING ASAF ALI ROAD, DELHI-110002
Improvement in Electrical Installation in Ultrasound Department and HOD Paediatrics department Kasturba Hospital.
2026_MCD_269246_3
79/MWEEE-I/2025-26/TC
Open Tender
Electrical Works
Percentage
180 days
CSPZ
refer special conditions
2 documents required · 2 mandatory
₹590
₹9,456
31 Mar 2026
2 Mar 2026
9 Mar 2026
2 Mar 2026
9 Mar 2026
2 Mar 2026
Wiring for light point / fan point / exhaust fan point /call bell point with 1.5 mm. sq FRLS insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI Box and earthing the point with 1.5 mm. sq FRLS insulated Copper conductor single core cable etc as required.
Group-"C"
Rewiring for light point/fan point/exahust point/call bell point with1.5SQmm FRLS PVC insulated copper conducter S/c cable and1.5 sq.mm.FRLS PVC insulated copper conductor S/C cable as earth wire in existing surface/recessed steel /PVCconduit,i/c dismentling asrequired.
Group-C
Supplying and fixing suitable size G.I box with Modular Plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps. modular socket outlet and 5/6 amps modular switch, connections, painting etc.as required.
Supplying and fixing suitable size G.I box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch, connections, painting etc.as required.
Supply & Drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required.
3x2.5 sq.mm.
6x2.5 sq.mm.
3x4 sq.mm.
5x4 sq.mm.
6x4 sq.mm.
Supply & fixing of following sizes of medium class PVC conduit alongwith accessories in surface/recess i/c painting in case of surface conduit,or cutting the wall & making good the same in case of recessed conduit as reqd.
Supply & Fixing of metal box of following size (nominal Size) on surface or in recess with following size of phenolic laminated sheet cover in front i/c painting etc.as required.
200 mm x 250 mm x 60 mm deep
S & F two module stepped type electronic fan regulator on the existing modular plate switch box i/c connection but excluding modular plate etc.as reqd.
Supply & Fixing following size/module,GI box alongwith modular base & cover plate for moduler switches in recess etc.as reqd.
8 Module (125 mm x 125 mm)
12 Module (250 mm x 150 mm)
S & F following Modular base & cover plate on existing modular boxes etc.as required.
8 Module
12 Module
Supply & Fixing following modular switch/socket on the existing modular plate & switch box i/c connections but excluding modular plate etc.as reqd.
5/6 Amp.Switch
15/16 Amp.Switch
3 pin 5/6 Amp.Socket Outlet
6 pin 15/16 Amp.Socket Outlet
Supplying & Fixing 20 A,240 V, SPN Industrial type socket outlet with 2 pole & earth,metal enclosed plug top alongwith20 A "C" curve,SP,MCB, in sheet steel enclosure, on surface or in recess,with chained metal cover for the socket out let & complete with testing & commissioning etc.as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 Way, Double Door
12 Way, Double Door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
6 way (4 + 18), Double door
Supply & Fixing Cable End Box (Loose Wire Box) suitable for following single pole & neutral,sheet steel,MCB distribution board,240 Volts,on surface/recess,complete with testing & commissioning etc,as required.
For 8 Way, Double Door SPN MCBDB
Supply & Fixing Cable End Box (Loose Wire Box) suitable for following Tripal pole & neutral,sheet steel,MCB distribution board,415 Volts,on surface/recess,complete with testing & commissioning etc,as required.
For 6 Way, Double Door TPN MCBDB
Supplying and fixing 5 A to 32 A rating, 240/415V,10 KA, "C" curve miniature circuit breaker suitable for inductive load of following pole in the existing MCB DB complete with connection testing and commissioning etc, as required.
Single Pole
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supply and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connection, testing and commissioning etc, as required.
P & F of 6 SWG dia.G.I. wire on surface or in recess for loop earthing along with existing surface/recessed conduit/submain wiring/cable as reqd.
Laying of one number pvc insulated and PVC sheathed/ XLPE power cable of 1.1 kv grade of following size in the existing masonary open duct as required
Upto 35 sq.mm.
Laying of one number pvc insulated and PVC sheathed/ XLPE power cable of 1.1 kv grade of following size in the existing surface as required
Upto 35 sq.mm.(Clamped with 1 mm thick saddle)
Supplying and installing following size of perforated painted with powder coating MS Cable tray with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
100 mm width X 50 mm depth X 1.6 mm thickness
Installation of exhaust fan in the existing opening,i/c making good the damage,connection,testing,commissioning etc.as reqd.
Upto 450 mm sweep
S/I/T/C of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000/4000/5700/6000/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCTshall be as approved by Engineer-in-Charge as per requirement.(Thermal management : hear sink of aluminium housing such that LED junction temperature shall not rise above 90 degree Centigrade) CRCA Sheet body (Thickness ≥ 0.50 mm)
S/I/T/C of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al bodyPower Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS:-374:2019 fan,Supply,earthing etc.as reqd.
1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
S/I/T/C of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved byEngineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). CRCA Sheet Body (Thickness > 0.50 mm).
SITC of wall mounted fan 400mm sweep rated voltage 220-230 AC rated frequency 50HZ speed 1280-1350 RPM with desired color
Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-4C*25 sqmm
Supply of 250 mm (10 inch) sweep 1250 rpm exhaust fan Fresh Air Type complete with shutter blades etc. as required.
S/o 15'' (380mm) sweep 1400 rpm exhaust fan heavy duty complete with shutter,blade etc as required.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.84 MB
Tendernotice_2.pdf
PDF • 26.38 MB
Tendernotice_3.pdf
PDF • 0.70 MB
DNIT03_0001.pdf
Tender Documents • 3.42 MB
BOQ_313523.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .