Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.6 LAdmitted-Finance | ₹39.6 L | L1 | Admitted-Finance |
| 2 | L2₹43.8 LAdmitted-Finance | ₹43.8 L | L2 | Admitted-Finance |
| 3 | L3₹44.9 LAdmitted-Finance | ₹44.9 L | L3 | Admitted-Finance |
| 4 | L4₹46.0 LAdmitted-Finance | ₹46.0 L | L4 | Admitted-Finance |
| 5 | L5₹49.9 LAdmitted-Finance | ₹49.9 L | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/s K L M INFRATECH L4 | SHRI GANESH ENTERPRISES L7 | Srinivasa Consructions L6 | BHAGYARAM ENTERPRISES L1 | SHILPA CONSTRUCTION COMPANY L3 | SUN LIGHT HOUSE L8 | MM PROJECTS L2 | M. Laxman Rao and sons L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Disconnecting the electric supply, removing the HT and LT cable connections and taking out the transformer of capacity 3500 KVA from the platform, lifting the transformer with suitable crane, loading into the goods carrier and shifting the transformer to an approved factory (workshop) for reairs and transporting back installation in its original location including connection of HT and LT cable connections all as directed by Engineer-in- Charge.
Note : Repairs to tranformer and testing will be measured and paid separately | 1 | Each Job | 90,000 ₹90,000 | 88,000 ₹88,000 | 1,10,000 ₹1.1 L | 70,000 ₹70,000 | 80,000 ₹80,000 | 80,000 ₹80,000 | 7,000 ₹7,000 | 63,000 ₹63,000 |
| 2.00 | M&L for draining out the transfomer oil, removing the inspection cover, lifting the core with suitable crane and removing the winding from the core replacing the unserviceable insulation of LV coil, HV coil and rewinding the unserviceable HV, LV coil turns with new electrolytic copper conductor, drying of core and winding in the oven upto required IR values, assembling the core with new insulation, replace the unserviceable LT, HT bushing washers, oil seal, gaskets of inspection cover with new ones, conduct all testing, commissioning complete for 3500 KVA Transformer all as directed by Engineer-in-Charge.
Note : HT / LT bush, transformer oil, LV, HV coils, inspection cover gasket and testing of transformer will be measured and paid separately under relevant items. | 1 | Each Job | 92,000 ₹92,000 | 3,45,000 ₹3.5 L | 1,10,000 ₹1.1 L | 25,000 ₹25,000 | 90,000 ₹90,000 | 75,000 ₹75,000 | 7,500 ₹7,500 | 63,000 ₹63,000 |
| 3.00 | M&L for making HV / LV coil insulation with required gauge of craft paper cotton tape as per specification of old transformer of capacity of 3500 KVA complete all as directed by Engineer -in-Charge. | 1,500 | KG | 150 ₹2.3 L | 130 ₹1.9 L | 200 ₹3 L | 100 ₹1.5 L | 150 ₹2.3 L | 260 ₹3.9 L | 170 ₹2.5 L | 300 ₹4.5 L |
| 4.00 | M&L for making HT coil insulation with required gauge of craft paper cotton tape as per specification including copper wire of required gauge as per specification of old transformers capacity 3500 KVA complete all as specified and directed by Engineer -in-Charge. | 1,500 | KG | 1,400 ₹21 L | 1,705 ₹25.6 L | 1,520 ₹22.8 L | 1,000 ₹15 L | 1,347 ₹20.2 L | 1,450 ₹21.8 L | 1,500 ₹22.5 L | 1,350 ₹20.3 L |
| 5.00 | M&L for conducting oven charges for removing of moisture and cure insulating varnish leading to electrical failure so as to restore electric strength for 3500 KVA capacity Transformer | 1 | Each Job | 15,000 ₹15,000 | 22,000 ₹22,000 | 20,000 ₹20,000 | 25,000 ₹25,000 | 1,50,000 ₹1.5 L | 15,500 ₹15,500 | 15,000 ₹15,000 | 15,000 ₹15,000 |
| 6.00 | M&L for conducting the following tests after repairs of transformers capacity upto 3500 KVA including submitting the test report.
(a) I.R values of HV to LV, HV to Earth and LV to Earth.
(b) winding resistance.
(c) Ratio test
(d) No-load test
(e) Short circuit test
(f) Dielectric strength of oil
(g) Transfomer tap switch positions
Note: contractor shall arrange all measuring instuments / equipment for testing of transformer. | 1 | Each Job | 10,000 ₹10,000 | 25,000 ₹25,000 | 15,000 ₹15,000 | 10,000 ₹10,000 | 11,805 ₹11,805 | 20,000 ₹20,000 | 7,000 ₹7,000 | 16,000 ₹16,000 |
| 7.00 | Supply and fix HT / LT porcelain bush rods and Top cover gaskets suitable for any make of transformer of capacity 3500 KVA all as directed by Engineer-in-Charge | 1 | Each Job | 70,000 ₹70,000 | 65,000 ₹65,000 | 80,000 ₹80,000 | 5,000 ₹5,000 | 70,800 ₹70,800 | 55,000 ₹55,000 | 70,000 ₹70,000 | 6,000 ₹6,000 |
| 8.00 | M&L for servicing of OLTC of 3500 KVA capacity Transformer includes draining the transformer oil and inspect the die electric strength, check for wear & tear, pitting and carbon buildup on the arcing and selector contacts, assess and replace the worn or damaged components like contacts, springs & gaskets with newone, inspect & lubricate the drive mechanism inside the diverter switch, control circuit and also inspect the control cabinet incl motor drive panel and tests its proper operation and do the adanced electrical test like Dynamic Resistance Measurement (DRM) if needed all as specified and directed by the Engineer-in-Charge. | 1 | Each Job | 29,000 ₹29,000 | 35,000 ₹35,000 | 35,000 ₹35,000 | 25,000 ₹25,000 | 30,705 ₹30,705 | 35,000 ₹35,000 | 30,000 ₹30,000 | 45,000 ₹45,000 |
| 9.00 | Supply and replacing of transformer oil conforming to IS: 335 (1993), dielectric strength not less than 60 KV at 2.5 mm gap in various capacities distribution transformers installed at various indoor and outdoor sub stations complete all as specified and directed.
Make: Power oil / SERVO / Castrol / Shell. | 3,500 | Ltr | 160 ₹5.6 L | 140 ₹4.9 L | 190 ₹6.7 L | 150 ₹5.3 L | 132 ₹4.6 L | 200 ₹7 L | 120 ₹4.2 L | 181 ₹6.3 L |
| 10.00 | Dehydration of transformer oil of various capacities distribution transformers installed at various indoor and outdoor transformers with ultra high vaccum filtration machine to obtain the dielectric strength of 60 KV at 2.5 mm gap complete all as specified and directed. | 10,000 | Ltr | 9 ₹90,000 | 10 ₹1 L | 10 ₹1 L | 10 ₹1 L | 8 ₹80,000 | 12 ₹1.2 L | 3 ₹30,000 | 9 ₹90,000 |
Updated dates
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
17 Feb 2026, 3:00 pmClosed
GE(I) R AND D RCI, HYDERABAD
GE(I) RND RCI, MILITARY ENGINEER SERVICES, VIGNYANAKANCHA, RCI, HYDERABAD
REPAIRS TO THE DISTRIBUTION TRANSFORMERS AT CARBON -CARBON SUB STATION AND ELSEC SUB STATION AND RECENTLY TAKEN OVER FROM CCE SOUTH OF RCI UNDER GE I RND RCI HYDERABAD.
2026_MES_748245_1
8358
Open Tender
Electrical and Maintenance Works
180 days
GE(I) R AND D RCI, HYDERABAD
MES enlisted Class D category b ii enlisted Meeting enlistment criteria of D class in MES and having no recovery pending. For further details ref NIT.
8 documents required · 8 mandatory
₹500
Yes
GE(I) R AND D RCI, HYDERABAD
₹84,000
Yes
30 Mar 2026
13 Jan 2026
19 Feb 2026
13 Jan 2026
17 Feb 2026
27 Jan 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: GE(I) R&D RCI HYDERABAD
Name of Work: REPAIRS TO THE DISTRIBUTION TRANSFORMERS AT CARBON CARBON SUB STATION & ELSEC SUB STATION AND RECENTLY TAKEN OVER FROM CCE SOUTH OF RCI UNDER GE (I) R&D RCI, HYDERABAD
Contract No: GE(I) RCI/HYD/ OF 2025-2026
Sl No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency Basic Rate In Figures To be entered by the Bidder Rs. Ps. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e. DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit, if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes Total Amount With Taxes Total Amount In Words
Disconnecting the electric supply, removing the HT and LT cable connections and taking out the transformer of capacity 3500 KVA from the platform, lifting the transformer with suitable crane, loading into the goods carrier and shifting the transformer to an approved factory (workshop) for reairs and transporting back installation in its original location including connection of HT and LT cable connections all as directed by Engineer-in- Charge. Note : Repairs to tranformer and testing will be measured and paid separately 1 Each Job Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
technical_837936.pdf
techsummary_837936.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.09 MB
BOQ_837936.xls
BOQ • 0.28 MB
8358PS.pdf
Tender Documents • 0.34 MB
Download all tender documents and submit your bid