Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.9 LAccepted-AOC C O S 1 ESS GEE COMPLEX NEAR J K BANK SONAWAR BAZAR B B CANTT SRINAGAR 190004 J K | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190004 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹12.9 L+₹1.7 L (14.8%)Rejected-Finance | L2 | Rejected-Finance Being not a lowest bidder | |
| 3 | L3₹14.0 L+₹2.7 L (23.9%)Rejected-Finance | L3 | Rejected-Finance Being not a lowest bidder | |
| 4 | L4₹14.0 L+₹2.8 L (24.4%)Rejected-Finance KHUNMOH SRINAGAR PIN 191104 J K | SRINAGAR | SRINAGAR | J K | 191104 | L4 | Rejected-Finance Being not a lowest bidder | |
| 5 | L5₹15.7 L+₹4.4 L (39.2%)Rejected-Finance AZAD COLONY B 90 FEET ROAD SOURA SRINAGAR J K 190011 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190011 | L5 | Rejected-Finance Being not a lowest bidder |
Tender Value
Refer Docs
EMD Value
₹40,400
Closing Date
19 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 861 EWS
GE 861 EWS PIN-913861 C/O 56 APO
CERTAIN REPAIR REPLACEMENT TO INTERNAL ELECTRIC FITTINGS AND FIXTURES AT VARIOUS UNITS AT WAZUR UNDER AGE EM OF GE 861 EWS
2021_MES_452039_1
GE 861EWS-13/2021-2022
Open Tender
Construction Works
Item Rate
180 days
GE 861 EWS
AS PER NIT
8 documents required · 8 mandatory
₹500
GE 861 EWS
₹40,400
Yes
22 Aug 2021
16 Jun 2021
21 Jul 2021
16 Jun 2021
19 Jul 2021
5 Jul 2021
60 days
Amount
Taking down carefully aluminum/copper point wiring (light fan socket or power) complete with fitting such as switches, tube lights, ceiling rose, pendants, regulators, MCB DB, MCB'S, Main switch from control board and making good disturbed surfaces of walls, floor to match with existing specification complete and all as specified keeping aside regulators/ light fitting/ MCBs serviceable/ unserviceable items for reuse with in the same bldg or deposited to MES store yard
Point wiring for one light point/fan point controlled by one switch with 1.5 sqmm PVC FRLS insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and including PVC casing and capping/Conduit medium grade of suitable size run on wall/surface with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box of required size or PVC Gang Box all as directed by Engr in Charge & 3mm thick plastic laminated sheet, including cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified.
All as per srl item No-2 here in above but for one 3 pin 5A socket outlet independent controlled by one switch.
All as per srl item No-2 here in above but for one 5A socket outlet on the same board controlled by one switch.
All as per srl item No-2 here in above but for one 3 pin 15 Amps socket outlet independent with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 2.5 Sqmm PVC FRLS insulated unsheathed copper conductor single core cable (green color) as earth lead.
M&L for Switch piano flush button single pole one way 5 amps 240 volts, complete all as required at site or directed by Engr-in- charge.
M&L for Switch Socket combination 2 in 1, 5 Amps flush type, 230 volts, complete all as required at site or directed by Engr-in- charge.
M&L for Switch Socket combination, 6 pin 5 and 15 amps multi purpose 2 in 01 flush type, 230 volts, complete all as required at site or directed by Engr-in- charge.
S&F bell push flush type 6 Amps 240 Volt, complete all as required at site or directed by Engr-in- charge.
S&F bell/buzzer multi music type AC 230 volts single pole, complete all as required at site or directed by Engr-in- charge.
Supply and fixing Socket outlet 2 in 1, 5 Amps 5 pin flush type, 230 volts .
Supply and fixing Socket outlet 2 in 1 ,3 pin 5/15 amps flush type, 230 volts.
Supply and fixing in replacement fan regulator electronic, stepped type flush type on existing sheet etc. AC 230 volts ISI marked with and including connecting electrically all as required at site or directed by engineer-in-charge.
S & F Lamp holder angular/straight insulated body with back plate for batten fittings.
S&F decorative ultra slim linear LED in replacement of 18 Watt , 4 ' long lighting fixture with extruded Al heat sink , environment friendly , energy efficient ready to use pack incl LED tube complete with inbuilt electronic driver , PCB , connector block etc including connecting up with three core twisted flexible copper conductor cable with suitable size LED tube all as specified and directed by EIC. Make : Havells Cat Part No LHDD02102674 or Equivalent/C&S/Bajaj.
S&F decorative ultra slim linear LED in replacement of 18 Watt , 4 ' long warm colour lighting fixture with extruded Al heat sink , environment friendly , energy efficient ready to use pack incl LED tube complete with inbuilt electronic driver , PCB , connector block etc including connecting up with three core twisted flexible copper conductor cable with suitable size LED tube all as specified and directed by EIC. Make : Havells Cat Part No LHDD02102674 or Equivalent/C&S/Bajaj.
Supply and fixing in repair LED bulk head fitting 9 W in engineering plastic housing with clear prismatic diffuser, including LED lamp and all accessories for fixing on wall all as specified and directed by Engr-in-Charge.
Supply and fixing in repair LED lamp 07W, 240V, complete all as specified and directed by Egnr-in-Charge.
Supply and fixing in repair LED lamp 09W warm colour, 240V, complete all as specified and directed by Egnr-in-Charge.
Supply & fixing in repair ceiling rose, 3 phase/PVC/polycarbonate isolated body complete all as specified & directed by Engineer -in- Charge.
Supply and fixing in repair oil filled capacitor of 2.5 mfd AC 230 Volts 50 Hz complete all as specified and directed by Engr-In-Charge.
Fixing only exhaust fan 230mm to 250mm sweep PVC body with louvers, 240 volts AC single phase, 50 Hz, ISI marked, including necessary work in wall/sheet, including connection cable of suitable size, nut bolt and other fixing material complete all as specified and directed by Engr-in-Charge Note: Exhaust Fan will be supplied by department free for fixing under Schedule "B"
Supply and fixing in repair modular one way switch 6 Amp 240 volte suitable for 1 module etc complete as specified and directed.
Supply and fixing in repair modular socket outlet, 6A-2/3 pin combined 2 module, 230 volts complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repair modular switch1 way 16A, 1 module single pole, 230 volts complete all as specified & directed by Engr-in-Charge.
Supply and fixing in repair modular socket outlet, 6A/16A-2/3 pin combined 2 module, 230 volts complete all as specified & directed by Engr-in-Charge.
Supply and fixing in repair modular ceiling fan step regulator, 120W-2 module switsh/socket type, AC 230 volts, duly ISI marked complete all as specified & directed by Engr-in-Charge.
Supply and fixing in repair modular white cover plate with frame, 4 module duly ISI marked complete all as specified & directed by Engr-in-Charge.
Supply and fixing in repair modular white cover plate with frame, 6 module duly ISI marked complete all as specified & directed by Engr-in-Charge.
Supply and fixing in repair modular white cover plate with frame, 8 module duly ISI marked complete all as specified & directed by Engr-in-Charge.
Supply and fixing in repair GI/MS sunken (metal) box of suitable size and design for modular white cover plate of 4 module made up of 1.6 mm thick GI/MS sheet all as specified and directed by Engr-in-Charge
Supply and fixing in repair GI/MS sunken (metal) box of suitable size and design for modular white cover plate of 5 module made up of 1.6 mm thick GI/MS sheet all as specified and directed by Engr-in-Charge
Supply and fixing in repair GI/MS sunken (metal) box of suitable size and design for modular white cover plate of 6 module made up of 1.6 mm thick GI/MS sheet all as specified and directed by Engr-in-Charge
Fixing only water heater vertical type ,stationary storage type of 25 ltr capacity 240 volts with heating element including fixing arrangement nut bolts, washer/fasteners and finishing work etc complete as per existing surface, all as specified and directed by Engr-in-Charge. Note : Water heater vertical type ,stationary storage type of 25 ltr capacity will be supplied by department free for fixing under Schedule "B"
Supply and fix in repair MCB Distribution board , 240 volts single pole and neutral , double door, sheet steel, enclosure powder coated with 200 Amps rated copper busbar with neutral link, 4 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection and making good distributed wall surfaces to match with existing specification including taking down existing, complete all as specified and directed by Egnr-in-Charge.
Supply and fix in repair MCB Distribution board , 240 volts single pole and neutral , double door, sheet steel, enclosure powder coated with 200 Amps rated copper busbar with neutral link, 8 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection and making good distributed wall surfaces to match with existing specification including taking down existing, complete all as specified and directed by Egnr-in-Charge.
Supply and fixing in repair MCB, SP, AC, 240 volts "B" series capacity of 06 to 32 Amps, 10kA and making connections complete all as specified & directed .
Supply & fixing in repair MCB, DP (Double Pole), AC, 240 volts, B series capacity 20 Amps to 32 Amps 10kA and making connections complete all as specified & directed.
S&F in repair including connecting Isolator triple pole neutral (TPN) 63 Amps 415 Volts with rupturing capacity 10 KA,as specified and directed by Engr-in-charge.
M & L for replacement of heating element AC 230 volt of rating 1500 watt ISI marked triangular/circular type complete all as specified.
M & L for replacement of heating element AC 230 volt of rating 2000 watt ISI marked triangular/circular type complete all as specified.
M & L for replacement of old unserviceable thermostat switch with Thermostat switch for geyser AC 230 volt adjustable range complete all as specified.
Supply and fixing in repair cable PVC FRLS insulated unsheathed with flexible multistranded copper conductor of size 1.5 Sqmm 1100 Volts grade as per site requirement of existing colour coding adopted.
Supply and fixing in repair cable PVC FRLS insulated unsheathed with flexible multistranded copper conductor of size 2.5 Sqmm 1100 Volts grade as per site requirement of existing colour coding adopted.
Supply and fixing in repair cable PVC FRLS insulated unsheathed with flexible multistranded copper conductor of size 4.0 Sqmm 1100 Volts grade as per site requirement of existing colour coding adopted.
Supply and fixing in repair flexible wire twin core 1100 volt grade 0.75 sqmm copper conductor multistraneded all as specified and directed.
Fixing only ceiling fan 1200 mm sweep, blade set of 3 including connection with three core copper wire etc complete all as specified and directed by engr-in-Charge. Note : Ceiling Fan will be supplied by department free for fixing under Schedule "B"
Supply laying connecting and testing in repair 1100 volt graded heavy duty XLPE cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 16 Sqmm normal cross section 4.0 core including suitable size lugs laid in trenches fixed to pole or passing through pipes incl all necessary clamps nuts, bolts and washers and remove unsv cable complete all as specified.
Supply and laying in repair service cable 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed 4 sqmm 2 Core nominal cross section complete all as specified and directed.
Supply and laying in repair service cable 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed 6 sqmm 2 Core nominal cross section complete all as specified and directed.
Supply and laying in repair service cable 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed 10 sqmm 2 Core nominal cross section complete all as specified and directed.
S&F in repair connecting and testing change over switch Single pole 415 volts on load of rating 63 Amp and including sheet enclosures complete including taking out to old u/s switch complete all as specified.
S&F in repair connecting and testing change over switch Single pole 415 volts on load of rating 100 Amp and including sheet enclosures complete including taking out to old u/s switch complete all as specified.
Supply and fixing in repair Plug top 3 pin 5 amps 230 volts.
Supply and fixing in repair Plug top 3 pin 15 amps 230 volts.
Supply and fixing in repair casing caping of 25mm bore dia medium grade, all as specified and directed by Engineer - in - Charge
Taking down old/UNSV fluorescent security light/street lights and S&F LED 30 Watt security light Energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP66 protection and impact resistance of IK07 complete all as per directed by EIC. Make Havells Cat Part No ENDURACITYLITEPLATSL30WLED757SASYBOPC or equivalent/CROMPTON GREAVES/GE.
Material & labour in repair of earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx6mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level. connecting to the GI wire 4 mm dia by means of bolls, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI light grade pipe 15mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering , perforated at bottom. 1.75 metre long placed on top edge of earth plate. charcoal and common salt filling with fixing arrangement, funnel wire mesh and earth work in soft soil returning filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate 3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion. NOTE :- (i) Item of earthing includes cost of 7.5 m long GI wire of size 4 mm dia with protection pipe of 15mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates enhanced by 25%. (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
M/S Sheikh and Co
BHAT ENGINEERS
M/S HAFIZ AND SONS
FG CONSTRUCTION
M/S Manzoor Constructions
M/S HAMID & CO
M/S SHAH RAOUF
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .