Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.2 LAccepted-AOC C 410 PRAGYA LANE SHYAM NAGAR KANPUR 208013 | KANPUR | KANPUR | UTTAR PRADESH | 208013 | L1 | Accepted-AOC Being (L1) | |
| 2 | L2₹27.9 L+₹2.1 L (8.29%)Rejected-Finance 24 SHANTI BHAWAN DHARI ROAD BELTARI PITHORAGARH UTTARAKHAND 262520 | PITHORAGARH | UTTARAKHAND | 262520 | L2 | Rejected-Finance Other than (L1) | |
| 3 | L3₹28.1 L+₹2.4 L (9.20%)Rejected-Finance | L3 | Rejected-Finance Other than (L1) | |
| 4 | L4₹29.7 L+₹4.0 L (15.4%)Rejected-Finance H NO 200 GIRJA NAGAR 37 BN P A C LINE KANPUR 208015 | KANPUR | KANPUR | UTTAR PRADESH | 208015 | L4 | Rejected-Finance Other than (L1) | |
| 5 | L5₹30.1 L+₹4.4 L (17.0%)Rejected-Finance | L5 | Rejected-Finance Other than (L1) |
Tender Value
₹34.4 L
EMD Value
₹68,800
Closing Date
14 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF) EM Chakeri
Area under GE(AF) EM Chakeri, Kanpur-08
Periodical Services and other BR repair to EM installation and other misc work at AFS Kanpur
2023_MES_575983_1
8607/E8
Open Tender
Civil Works
Item Rate
180 days
Area under GE(AF) EM Chakeri
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GE(AF) EM Chakeri
₹68,800
Yes
24 Mar 2023
19 Jan 2023
20 Feb 2023
20 Jan 2023
14 Feb 2023
2 Feb 2023
Amount
Preparation of old decorated surface by complete removal of existing treatment on walls/coloumns, bracings, domes and all as directed by Engr-in-Charge. NOTE- This stage will be physically passed by GE/Engr-in-Charge before progressing further coarse of process.
M&L for applying for anti fungal weather proof wall care putty on coloumns, bracings, domes on overhead reservoir upto 24 Mtrs height including leveling/edging the disturbed place/edge upto thickness 1mm to 2mm and using necessary filling compound of wall care putty to obtain smooth regular/even finish using sand paper all as directed by Engineer in Charge. NOTE- This stage will be physically passed by GE/Engr-in-Charge before progressing further any coat of antifungal weather coat primer / paint.
M&L applying for anti fungal weather proof wall care putty on walls including leveling/edging the disturbed place/edge upto thickness 1mm to 2mm and using necessary filling compound of wall care putty to obtain smooth regular/even finish using sand paper . NOTE- This stage will be physically passed by GE/Engr-in-Charge before progressing further any coat of antifungal weather coat primer / paint.
M&L for applying one coat of 100% anti fungual acrylic emulsion exterior grade weather proof paint over a coat of weather resistent Acrylic primer on prepared surface of wall complete all as direct by the Engr-in-Charge.
M&L for applying two coats of 100% anti fungual acrylic emulsion exterior grade weather proof paint over a coat of weather resistent Acrylic primer on prepared surface of coloumns, bracings, domes on overhead reservoir upto 24 Mtrs height complete all as direct by the Engr-in-Charge. In operation of each coat wise shall be got approved by GE in token of their satisfactory application and there after subsequent coat shall be applied complete all as directed by the Engr-in-Charge.
M&L for preparing of old decorated surfaces of walls ( plastered or un plastered ) including cornices etc and applying two coats of white wash complete all as specified and directed.
M & L for preparing of old decorated surfaces of ceilings and applying two coats of white wash complete all as specified & directed by Engineer in Charge .
M & L for preparation of old painted wooden surface of any description, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint all as directed and specified by Engr-in-Charge..
M & L for one coat of synthetic enamel paint including preparation of old decorated steel surfaces of any description over 10 Cm width or girth not otherwise described all as directed.
M & L for writing letters or figures (Block, Roman, Italic or Indian) n exc 30 cm high complete all as specified and as directed by the Engineer-in-Charge
M&L for preparing of old decorated surfaces of walls ( plastered or un plastered ) including cornices etc and applying one coat of oil bound distemper, complete all as specified and directed.
M&L for preparing of old decorated surfaces of walls ( plastered or un plastered ) including cornices etc and applying one coat of cement base paint, complete all as specified and directed
Demolition of Cement concrete (Unreinforced) of any description in ground floors and pavings n exe 15 cm thickness (below or above ground level) complete all as directed.
M&L for 75 mm thick cement concrete (1:3:6) type C-2 (using 40mm graded stone agg) as in flooring/plinth protection/sub-base finishing concrete surface even and smooth without using extra cement complete all as specified and directed.
Supply and spreading of sand filling / sand cushioning not exceeding 25mm thick as filling under floors including watering and consolidation complete all as specified and directed.
M&L machine pressed, precast concrete, glazed interlocking paver block (having rubber moulded finish) any shape and size, confirming to IS 15658-2006 of 60 mm thick, M-35 grade with grey cement and pigment including all exposed sides of inter locking paver block shall locked with PCC (1:2:4) type B1 using 20 mm graded stone aggregate complete all as specified and directed. Note: Brand name shall be embosed in each paver blocks.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with oil putty or fixed with beads complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal frames including punching or drilling out old glazed pins / spring clip and providing and fixing new ones. complete all as specified and directed.
M & L for sheet glass 3.0mm thick, ordinary quality and glazing with oil putty in square n exc 0.5 sq m in each pane complete all as specified and as directed.
Dismantling of AC Corrugated Sheets as in Roofing including Ridge or Similar Pattern Roof Coverings, complete all as directed.
S & F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mps as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and as directed by Engr-in-Charge.
S & F Pre-painted galvaume aluminium zink coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified as in roof covering all as specified and directed.
Dismantling Wall and ceiling boards (fibre pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as directed.
M&L 16 mm thick of size 600 x 600 mm mineral fibre false ceiling system of pattern classic lite RH 99 (bevelled regular) of Armstrong or equivalent make and model including grid system using hot dipped galvanised steel section, exposed surface with pre-powder coated capping, main runner and cross runner and to comprise main tee/runner 15mm x 38 mm size (load carring capacity 14 kg/sqm) spaced at 1200 mm centres securely fixed to the structural soffit and flush fitting 1200 mm long cross tee/runner to be interlocked between main runners at 600 mm centre to centre from 1200 x 600 mm module, cut sub cross tee/runner 600 mm require independent support. Wall angle of size 19 mm x 19 mm, securred to the periphery of the wall at 450 mm maximum centres. The above grid is suspended at every 1200 mm centre to centre in both direction and starting from wall at the distance 350 mm from wall by using 3.50 mm dia aquline wire with suitable fasterners and hook clip complete all as specified and directed.
Demolition of cement Concrete of any description over roof slab complete all as specified and as directed by Engr-in-Charge.
M & L for 25mm thick cement concrete (1:2:4) type B-0, using 12.5 mm graded stone aggregate mixed with WPC @ 3.00 % by weight of cement complete all as specified and as directed by the Engineer-in-Charge Note:- WPC shall be measured & paid separately.
M & L for wire brushing and cleaning top surface of tiles, lime terracing or cement concrete, including flashings and junction of parapets, etc., and surface painting, with a layer of blown bitumen of any penetration applied hot @ 1.7 kg per sq. m, blinde complete all as specified and as directed by Engr-in-Charge.
M & L for brushing neat cement slurry with 3.0 kg of cement per sq. metre complete all as specified and as directed by Engr-in-Charge.
M & L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric(wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified and directed.
M & L for 20mm thick Screed bed or bedding layer in CM (1:6) for laying floor tiles, complete all as directed by the Engineer-in-Charge.
M & L for cement concrete tiles 25cm x 25cm x 22mm thick, machine pressed, set jointed and pointed in neat cement slurry with grey cement and no pigments, in floors, cut and polished complete all as specified and directed by the Engineer-in-Charge complete all as specified and as directed by Engr-in-Charge.
M & L providing, cement concrete in roof typeB0 1:2:4 (12.5mm graded) for copings, kneelers, apex stones, bed plates, kerbs not provided for complete all as specified and as directed by Engr-in-Charge .
Taking up or down 15mm bore steel tubing and connecxtions, including cleaning for Refixing or removal to store all as directed by Engineer in Charge.
Taking up or down 20mm dia bore steel tubing and connections including cleaning for rating and removal to store all as directed by Engineer in Charge.
Taking up or down 25 or 32 mm bore steel tubing and connections, including cleaning for refixing or removal to store all as directed by Engineer in Charge.
Taking up or down 40 or 50 mm bore steel tubing and connections, including cleaning for refixing or removal to store all as directed by Engineer in Charge.
S & F 15 mm bore Galvanized Steel tubes, medium grade for flush pipes, water supply pipes etc., fixed to walls and ceilling or laid in floors in short lengths complete all as specified & directed by Engineer in Charge.
S & F 20 mm bore Galvanized Steel tubes lights grade for flush pipes, water supply pipes etc., fixed to walls and ceilling or laid in floors in short length complete all as specified & directed by Engineer in Charge.
S & F 25 mm bore Galvanized Steel tubes, medium grade for flush pipes, water supply pipes etc., fixed to walls and ceilling or laid in floors in short lengths complete all as specified & directed by Engineer in Charge.
S & F 50 mm bore Galvanized Steel tubes, medium grade for flush pipes, water supply pipes etc., fixed to walls and ceilling or laid in floors in short lengths.
Refixing old steel tubing of 15mm bore and connections in new or old position (walls,cellings, floors etc.) all as directed by Engineer in Charge
Refixing old steel tubing of 20 mm bore and connections in new or old position (walls, cellings, floors etc.) all as directed by Engineer in Charge
Refixing old steel tubing of 25 mm bore and connections in new or old position (walls, cellings, floors etc.) all as directed by Engineer in Charge
Refixing old steel tubing of 50 mm bore and connections in new or old position (walls, cellings, floors etc.) all as directed by Engineer in Charge
S & F in repair 15 mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified & directed by Engineer in Charge
S & F in repair 20 mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified & directed by Engineer in Charge.
S & F in repair 25 mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified & directed by Engineer in Charge
S & F in repair 50 mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified & directed by Engineer in Charge.
Dismantling of floor, hearth or wall tiles / terrazo including cement mortar bedding (but not backing),removal servicable tiles to store and rubbish off the premises, all as specified and directed.
M&L rendering 10 mm thick in cement mortar 1:4 on wall of brick work or concrete surface, to receive tiles all as specified and directed.
M & L for 15mm thick screed screed bed or bedding layer in cement mortar 1:6 complete all as specified and as directed by Engr-in-Charge
Dismantling of stone slab and tiles of any type , any description or thickness laid bedded and pointed in any mortar as in floors,aprons etc,
M&L for 20-25 mm thick machine cut kota stone slab in floors ,setand jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed.
M&L for 7 to 8 mm area exc 0.09 and n exc .11 sqm of eash tile, coloured non skid ceramic tiles(Ist quality) as in floors set& jointed in neat cement slurry and pointed in white/coloured cement to match the tiles all as specified and directed
M&L for 300x200x 7mm coloured ceramic tiles(Ist quality) as in vertical surface set& jointed in neat cement slurry and pointed in white/coloured cement to match the tiles all as specified and directed.
M&L for chequerred Cement concrete tiles 20 cm X 20 cm X 25 mm thick, set jointed and pointed in neat cement slurry with mixture of white and grey cement in equal proportion and no pigment complete all as specified.
M&L for 19-20 mm thick machine cut Granite stone slab BLACK or RED table rubbed polished and round edges as in cooking plateform, steps and window cills and like in CM 1:4 includimg pointing in white cement (1:2) using marble dust with admixture of pigmen to match with shade of graniteomplete all as specified and directed.
M & L for 20 mm thick Screed bed or bedding layer in CM (1:6) for laying floor tiles etc, complete all as specified and as directed.
Dismantling damage/broken water tanks exc 250 and n.exc 500 ltrs and supply and fixed 500 ltrs rotational moulded polyethylene HDPE double layers water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I , including providing union for inlet and out let pipe of dia not less that 25mm and overflow pipe of 40mm dia of 300 mm long complete all as specified & directed by Engineer in Charge
S & Fixed in repairs ball valves high pressure PTMT with epozy coated aluminium rod & highdensity plastic ball screwed for iron pipe and fixed size 20mm dia all as specified & directed by Engineer in Charge.
M&L for taking up/removal plants or vegetation growth from wall upto roof level by means of cutting hole into brick wall and making good the surface of dismantled portion (not exc 150 sqm superfical area and not exc one brick depth) using brick bats/aggregate and plastering in cement mortar (1:4) to distributed portion and applying two coats of cement base paint to match the existing surfaces upto 5 mtr height complete all as specified and directed.
Taking down rolling shutters of any description not exceeding 10 Sq.m area straightening of certain springs, guide channel hood cover, etc and refixing the same to the original position including greasing/oiling i.e. complete servicing to make the shutter fully functional to the entire satisfaction of Engineer-in-Charge.
Supply and fixing in repair for curtain built up of interlocking lath sections of any size and description shall have a distance of 75mm between rolling centers formed cold rolled steel strips of 1.2mm thick with interlocking curls at both edges and deep corrugation at the centre with a bridge depth of not less than 12 mm to provide sufficient curtain stiffness including one coat of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surfaces and all as specified and directed.
Supply and fixing in repair for guide channel made up of mild steel deep channel section not less than 3.15mm thickness. Depth of guide channel should be 65mm and width should be 25mm for the lath section and there should be a clearance of 10mm between the guide wall and the end clips of the curtain. Each guide channel should be provided with a minimum of three fixing cleats as per the site requirement and spacing of cleats should not exceed 0.75m. The projecting fashion of guide channel should be embedded in grooves and channel should have a box welded on at the bottom to conceal the end of the sliding bolt when fixed on side and all as specified and directed.
Supply and fixing in repair of fabricated lock plate of riveted construction of any size and description made up of mild steel sheet not less than 3.15mm thickness supported with steel angle or Tee section as per existing site requirement with sliding bolts made up of flat iron 40X6 mm hand made type provided at the either ends to engage with suitable receiving pockets at the bottom of the guide channel and pulling handle hand made type made up of flat iron 25X6mm and all as specified and directed.
Supply and fixing in repair of bracket plate of any size and description made up 3.15 mm thick mild steel plate with 'U' clamp and stopper made up flat iron 40X6mm and welded to the appropriate place complete and fixed to wall with foundation bolts at the required height all as per the site requirement and directed.
Supply and fixing in repair of roller made of heavy duty 40mm nominal bore cast iron pipe and fixed with nuts and bolt to orm wheel, helical wire springs/rings and beveled gear including necessary nuts and bolts, split pins, holes etc complete all as per the site requirement and directed.
Supply and fixing in repair of hood cover of any size and any description made of mild steel sheet 1.0mm thick and fixed with necessary nuts and bolts by drilling to the wall complete all as per the site requirement and directed.
Demolition of Brickwork masonry, built in cement mortar complete all as directed .
M & L for brickwork with subclass `B` bricks, in straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and as directed.
Taking down cement of cement lime plaster of any description on brick or stone walls or concrete surfaces etc including ranking out joints hacking for key scrubbing down with water etc complete all as specified and as directed by the Engineer-in-Charge
M & L for rendering 15mm thick in cement plaster (1:4) on fair faces of external surface of brick work or concrete surfaces , finished even and smooth without using extra lime or cement complete all as directed by the Engr-in-Charge.
M & L for rendering 15mm thick in cement plaster (1:4) on fair faces of brick work or concrete surfaces , finished even and smooth without using extra lime or cement mixing with WPC mixing with water proofing compound by 3% of cement by weight or as per manufacturers instructions complete all as directed by the Engr-in-Charge. (Note :- WPC will be measured and paid separately)
M & L for rendering 15mm thick in cement plaster (1:6) on fair faces of brick work or concrete surfaces , finished even and smooth without using extra lime or cement all as directed by the Engr-in-Charge.
M&L rendering 5 mm thick in cement mortar 1:3 on ceiling of brick or concrete surface, finished fair and even all as specified and directed.
Supply only integral water proofing compound.
M&L for preparation of the newly plastered surfaces and applying two coats of cement base paint on walls all as specified and direcrted.
M&L for preparing the newly plastered surfaces and applying two coats of Oil bound distemper over a coat of primer on walls all as specified and direcrted.
M&L for preparing the newly plastered surfaces and applying three coats of white wash on walls all as specified and direcrted.
M&L three coats of white wash on newly plastered or unplastered surfaces of ceiling including preparation of surface complete all as specified and directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
M &L for excavating in post holes each n exc. 0.5 cum in soft/loose soil, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n exc. 25cm, watering and removing surplus soil to distance n exc 50m and making good surface complete all as specified and directed.
M&L for Plain Cement Concrete 1:2:4 Type B 2 (using 40 mm graded aggregate ,in foundations, filling and mass concrete complete all as specified and directed.
S&F medium grade mild steel work in tubular trusses including special shaped washer including all necessary drilling, bolting or riveting, etc and similar work complete using ERW or induction butt welded tubes conforming to I. S. 1161-1979 grade St. - 240. complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc. 1.5 sq. m but not exc 4 sq. m each complete all as directed.
Taking down Chowkats or Frame (without taking off shutter from the frame) n exc. 1.50 Sqm all as directed.
S&F Steel window with side hung shutter incl.box type hinges with steel handle of MS flat 25x5mm and 2nos tower bolt of 100mm long fixed to shutter comp. With glazing bar dovtailed or welded including one shop coat of primer complete all as specified & directed by Engineer in Charge.
S&F framed work such as grills ,framed guard bars barred iron doors ;ladders framed balusters railings and similar work conforming to Fe 410-0or Fe 310-0 complete all as specified & directed by Engineer in Charge.
S&F 1.25 mm thick Pressed steel frames of size 125mm x 60mm for single doors including necessary fixing lugs, hinges, lock strike plate, etc complete all as per IS provns complete all as specified & directed by Engineer in Charge.
M & L PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in filling in pressed steel frames complete all as specified and as directed by Engineer-in-Charge
S&F Butt hinges of 100 mm size, Medium weight, cold rolled mild steel and fixed,
S&F 250 mm long mild steel sliding door bolts, ISI marked clip type, stove enamelled black, with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed
S & F 150mm long mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed complete all as specified and as directed.
S & F 150mm mild steel pressed handles, oval type, stove enamelled black complete all as specified and as directed.
Supply & Fixing MS work as in hold fast etc conforming (Fe-410-0 or Fe-310-0) all as specified & directed by Engineer in Charge.
Material & labour PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in hold fast, PCC Bed blocks incl finished all exposed surfaces of concrete incl necessary form work etc.
S&F 2nd class hard wood 30mm thick plain framed panelled shutter two panels with veneered particle board with commercial face venners supplied and fixed to chowkhat .
M&L for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specified.
Supply and fix in repair steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay complete with glazing bars dovetailed or welded all as specified.
M&L for painting to new steel surfaces of any dedcription over 10 cm in with or girth,not otherwise describe and applying two coats of synthetic enamel paints over a coat of red oxide primer complete all as directed.
Dismantling of fencing post or struts (wood, steel, RCC) any section , post embedded in concrete , brick work, masonry etc , including taking out embedded portion and making good distrubed ground.
M & L for excavating in post holes each n exc. 0.5 cum in soft/loose soil, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n exc. 25cm, watering and removing surplus soil to distance n exc50m and making good surface.
M&L for Plain Cement Concrete 1:4:8 type D 2 (using 40 mm graded aggregate ,in foundations, filling and mass concrete complete all as specified and directed.
S & F for Mild steel angles , bars , flats, etc as in posts and struts in fencing including cutting tops to shape as supports for stiffening of fencing , wall ties, hold fasts, clamps plain angle cleats for securing purlins as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed..
Fixing only chain link fencing including line wires, any mesh size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire. complete all as specified and directed.
Supply only for Chain link MS galvanisd fencing of any size or type including line wires, any type of standards, rails, straining bolts, etc including provission of binding wire and all as specified and directed by Engr in Charge. Note: Unit weight of chain link fencing shall be min 5.8 Kg per Sqm)
Demolition of RCC in (other than ground floors) beams,chajjas,landing slab and similar suspended works all as specified and directed.
S & F mild steel bars TMT 6 to 8 mm dia cut to length bent to shape required incl. cranking bending spirally for hoop for columns ,hooking ends and binding with and including mild steel wire not less than 0.9mm dia deformed or twisted bars all as specified & directed by Engineer in charge.
Mild steel TMT bars 10mm dia and over, cut length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to complete all as specified and directed.
M & L for Formwork to faces of wall , lintel beam, window chajja etc and similar work; vertical or to batter complete all as specified and as directed by Engr-in-Charge .
M & L reinforcement cement concrete nominal mix Type B1 1:2:4 (20 mm graded aggregate) Beams, cantilevers, bressummers, lintels over 1.5m span using 20mm graded stone aggregate all as specified.
shanti trading company
M/s S.G. BUILDERS
DHARM ENTERPRISES
M/S SDS Construction Co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .