Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.4 LAccepted-AOC | L1 | Accepted-AOC DUE TO L1 BIDDER | |
| 2 | L2₹50.4 L+₹3.6 L (7.65%)Rejected-Finance PO PS BOMDILA DISTT WEST KAMENG ARUNACHAL PRADESH 790001 | BOMDILA | WEST KAMENG | ARUNACHAL PRADESH | 790001 | L2 | Rejected-Finance REJECTED DUE TO L2 BIDDER | |
| 3 | L3₹55.0 L+₹8.1 L (17.3%)Rejected-Finance | L3 | Rejected-Finance REJECTED DUE TO L3 BIDDER | |
| 4 | L4₹55.7 L+₹8.8 L (18.8%)Rejected-Finance | L4 | Rejected-Finance REJECTED DUE TO L4 BIDDER | |
| 5 | L5₹56.1 L+₹9.2 L (19.7%)Rejected-Finance | L5 | Rejected-Finance REJECTED DUE TO L5 BIDDER |
| Sl No | Description | Qty | Unit | M/s Paramount Association of India L2 | M/S DK TRADERS L9 | D.P. Traders L4 | M/s 99 Enterprise of India L5 | M/S ASHOK CONSTRUCTION L7 | M/S N D ENTERPRISES L8 | M/s GTC Enterprises L1 | M/S MURPHEW ENTERPRISES L3 | M/S HIGHLANDERS ASSOCIATE OF HIMALAYAS L6 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling of water tanks exc 500 ltrs & n exc 1000 ltrs capacity and removing to stores. | 15 | Each | 750 ₹11,250 Lowest | 1,450 ₹21,750 | 1,500 ₹22,500 | 900 ₹13,500 | 1,450 ₹21,750 | 1,400 ₹21,000 | 1,110 ₹16,650 | 1,300 ₹19,500 | 1,400 ₹21,000 |
| 2.00 | S & F rotational moulded poythene water storage tank of 1000 ltrs capacity (multilayered, cylindrical vertical with closed top) hoisted and fixed in position all as specified. | 15 | Each | 10,500 ₹1,57,500 | 11,500 ₹1,72,500 | 10,000 ₹1,50,000 | 10,300 ₹1,54,500 | 10,000 ₹1,50,000 | 11,600 ₹1,74,000 | 8,196.46 ₹1,22,946.9 Lowest | 10,500 ₹1,57,500 | 10,500 ₹1,57,500 |
| 3.00 | Dismantling of water tanks exc 250 ltrs & n exc 500 ltrs capacity and removing to stores. | 24 | Each | 700 ₹16,800 Lowest | 1,210 ₹29,040 | 1,320 ₹31,680 | 930 ₹22,320 | 1,300 ₹31,200 | 1,200 ₹28,800 | 751.24 ₹18,029.76 | 1,000 ₹24,000 | 950 ₹22,800 |
| 4.00 | S & F rotational moulded poythene water storage tank of 500 ltrs capacity (multilayered, cylindrical vertical with closed top) hoisted and fixed in position all as specified. | 24 | Each | 5,400 ₹1,29,600 | 5,500 ₹1,32,000 | 4,400 ₹1,05,600 | 5,000 ₹1,20,000 | 4,400 ₹1,05,600 | 4,900 ₹1,17,600 | 4,219.6 ₹1,01,270.4 Lowest | 5,500 ₹1,32,000 | 5,400 ₹1,29,600 |
| 5.00 | Disconnecting existing water tanks of capacity exc 250 ltrs but n exc 500 ltrs, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position incl cleaning and removing all scale and dirt etc, from tanks and from mouths of circulating pipes etc complete all as specified and directed. | 90 | Each | 400 ₹36,000 Lowest | 600 ₹54,000 | 700 ₹63,000 | 550 ₹49,500 | 620 ₹55,800 | 590 ₹53,100 | 940 ₹84,600 | 610 ₹54,900 | 600 ₹54,000 |
| 6.00 | Disconnecting existing water tanks of capacity exc 500 ltrs but n exc 1000 ltrs, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position incl cleaning and removing all scale and dirt etc, from tanks and from mouths of circulating pipes etc complete all as specified and directed. | 42 | Each | 450 ₹18,900 Lowest | 600 ₹25,200 | 700 ₹29,400 | 650 ₹27,300 | 690 ₹28,980 | 690 ₹28,980 | 705 ₹29,610 | 700 ₹29,400 | 700 ₹29,400 |
| 7.00 | M & L for storage tanks exc 250 ltrs and nexc 500 ltrs, Cleaning & Sterilization of PVC/RCC Water Tanks through Bacteriological treatment by using TERBAC-G5,TERBAC-G65 and Ultra violet Ray with following procedure :- (a) Drain out water by using exit valve or own high capacity de watering system. (b) Cleaning all the algae formation inside the tank by using TERBAC-G10 a labotatory tested branded chemical of the company and scrubbing the walls of the tanks. (c ) Fresh water cleaning by high speed jet pump with pressure 5 PSI. (d) First bacteria screening is sterilization by using TERBAC-G5 a laboratory certified branded halogen compound, test certificate of TERBAC -G5 from govt lab mentioning suitability for sterilization should be submitted to the office before using for sterilization. (e ) Claning the bottom of the tank by heavy duty industrial vaccuum cleaner. (f) Secound bacteria screening and sterilizing method by using ultra voilet ray ejector covering 360 degree with in the tanks and kills all suspended bacteria. (g) Cleaning and third bacteria screening is to sterlize the floor of the water tanks by using Lab certifyied branded strong oxidizing agent TERBAC- G65, Test cetificate of TERBAC- G65 from Govt Lab mentioning suitability for sterilization should be submitted to the office before using sterilization. | 250 | Each | 700 ₹1,75,000 Lowest | 770 ₹1,92,500 | 770 ₹1,92,500 | 750 ₹1,87,500 | 750 ₹1,87,500 | 750 ₹1,87,500 | 720 ₹1,80,000 | 750 ₹1,87,500 | 760 ₹1,90,000 |
| 8.00 | As per item No 7 above but storage tanks exc 500 ltrs and nexc 1000 ltrs | 150 | Each | 900 ₹1,35,000 | 1,110 ₹1,66,500 | 1,100 ₹1,65,000 | 1,000 ₹1,50,000 | 1,100 ₹1,65,000 | 1,100 ₹1,65,000 | 820 ₹1,23,000 Lowest | 1,000 ₹1,50,000 | 1,000 ₹1,50,000 |
| 9.00 | S & F in Repair Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe pf 20mm dia or brass ferrule and fixed all as specified and directed. | 140 | Each | 500 ₹70,000 | 600 ₹84,000 | 550 ₹77,000 | 500 ₹70,000 | 590 ₹82,600 | 590 ₹82,600 | 460 ₹64,400 Lowest | 600 ₹84,000 | 500 ₹70,000 |
| 10.00 | Fixing only of Ball brass valves, high pressure with polythene float and flyout complete, screwed for iron pipe of 20 mm dia or brass ferrule and fixed all as specified and directed. | 20 | Each | 100 ₹2,000 | 1,000 ₹20,000 | 1,110 ₹22,200 | 110 ₹2,200 | 1,100 ₹22,000 | 990 ₹19,800 | 82.91 ₹1,658.2 Lowest | 900 ₹18,000 | 110 ₹2,200 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
2 Aug 2025, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE TENGA
GE TENGA PIN- 790116 C/O 99 APO
ROOF TREATMENT WITH REPAIRS AND REPLACEMENT AND CERTAIN MISC B/R ITEMS PHASE-I (RUPA, GACHHAM, BIRPUR, DP, BOMDILA) OF AGE B/R UNDER GE TENGA.
2025_MES_715032_2
8004/E8
Open Tender
Civil Works
Item Rate
270 days
GE TENGA
PLS REF NIT
7 documents required · 7 mandatory
₹500
GE TENGA
₹96,000
Yes
26 Sept 2025
15 Jul 2025
4 Aug 2025
15 Jul 2025
2 Aug 2025
22 Jul 2025
Amount
Dismantling of water tanks exc 500 ltrs & n exc 1000 ltrs capacity and removing to stores.
S & F rotational moulded poythene water storage tank of 1000 ltrs capacity (multilayered, cylindrical vertical with closed top) hoisted and fixed in position all as specified.
Dismantling of water tanks exc 250 ltrs & n exc 500 ltrs capacity and removing to stores.
S & F rotational moulded poythene water storage tank of 500 ltrs capacity (multilayered, cylindrical vertical with closed top) hoisted and fixed in position all as specified.
Disconnecting existing water tanks of capacity exc 250 ltrs but n exc 500 ltrs, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position incl cleaning and removing all scale and dirt etc, from tanks and from mouths of circulating pipes etc complete all as specified and directed.
Disconnecting existing water tanks of capacity exc 500 ltrs but n exc 1000 ltrs, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position incl cleaning and removing all scale and dirt etc, from tanks and from mouths of circulating pipes etc complete all as specified and directed.
M & L for storage tanks exc 250 ltrs and nexc 500 ltrs, Cleaning & Sterilization of PVC/RCC Water Tanks through Bacteriological treatment by using TERBAC-G5,TERBAC-G65 and Ultra violet Ray with following procedure :- (a) Drain out water by using exit valve or own high capacity de watering system. (b) Cleaning all the algae formation inside the tank by using TERBAC-G10 a labotatory tested branded chemical of the company and scrubbing the walls of the tanks. (c ) Fresh water cleaning by high speed jet pump with pressure 5 PSI. (d) First bacteria screening is sterilization by using TERBAC-G5 a laboratory certified branded halogen compound, test certificate of TERBAC -G5 from govt lab mentioning suitability for sterilization should be submitted to the office before using for sterilization. (e ) Claning the bottom of the tank by heavy duty industrial vaccuum cleaner. (f) Secound bacteria screening and sterilizing method by using ultra voilet ray ejector covering 360 degree with in the tanks and kills all suspended bacteria. (g) Cleaning and third bacteria screening is to sterlize the floor of the water tanks by using Lab certifyied branded strong oxidizing agent TERBAC- G65, Test cetificate of TERBAC- G65 from Govt Lab mentioning suitability for sterilization should be submitted to the office before using sterilization.
As per item No 7 above but storage tanks exc 500 ltrs and nexc 1000 ltrs
S & F in Repair Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe pf 20mm dia or brass ferrule and fixed all as specified and directed.
Fixing only of Ball brass valves, high pressure with polythene float and flyout complete, screwed for iron pipe of 20 mm dia or brass ferrule and fixed all as specified and directed.
Material and labour for taking down of existing tarfelt and bituminous compounds in roof of any description from roof or terracing, roughening surfaces of old concrete surface by picking out,sweeping clean and washing down with water to remove dust etc providing 15mm thick screed bed or bed or bedding layer of cement mortar (1:4) for laying waterproofing membrane and finishing surface even and smooth without using extra cement and providing waterproofing treatment over smooth finished surfaces after applying one coat of cold bituminous primer at the rate of 0.30 ltrs / Sqm , providing laying APP polymer, modified , non-woven polyster mat,reinforced membrane, 3mm thick (min) weighing 3.50 Kg/Sqm with surface finish of white mineral ,by torch application method , with minimum 75mm overlap on longitudinal direction and 100 mm overlap on the transverse direction and finally applying one coat of bituminous based solar reflective aluminium paint @ 100Gms /Sqm over APP modified membrane all as specified and directed by Engr-in-Charge.
Demolition and breaking up CI/AC/PVC drain pipes (Salt glazed ware, AC or Reinforced concrete) of 100mm dia.
S&F PVC (SWR) pipes single socketed 110mm dia in any length with rubber ring joints fixed to walls
S&F PVC (SWR) pipes single socketed 75mm dia in any length with rubber ring joints fixed to walls
S&F PVC (SWR) bends any radius, with access door 110mm dia.
S&F PVC (SWR) junction single, (single T) equal or unequal with access door 110mm dia.
S&F PVC (SWR) bends any radius, with access door 75mm dia.
Demoloition of Cement concrete (unreinforced) of any description and in any situation not otherwise specifically provided for complete all specified and directed.
M&L for cement concrete type B-1, 1:2:4 (20mm graded agg) as inchajja, roof kerbs or mud stops, levelling course/roof pedding, surface finished even and smooth w/o using extra cement.
Material and labour for providing cement concrete 1:2:4 type B-1 using 20 mm graded aggregate ) in plinth walls or retaining walls,drain walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases)
Use and waste flat form work to vertical faces of drain/retaining wall and similar work .
M&L for Cement concrete type B-2, 1:2:4 (using 40mm graded agg) as in surface channels and drains complete all as specified and directed.
M&L for 75mm thick Pcc type C-2, 1:3:6 (using 40mm graded stone agg) as in plinth protection complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi- tred/stopped ends etc
M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces with CM 1:4 finished even smooth without using extra cement complete all as specified.
Taking down of cement or cement lime plaster/tile work any description from brick or stone wall etc. including raking out of joints, hacking for key, scrubbing down with water etc.
M&L for rendering 15 mm thick cement plaster on external surface in CM 1:6 on brick & concrete surfaces and finished even and smooth (without using extra cement) all as specified and directed.
M&L Preparing new plastered surfaces and applying Two coats of cement base paint over one coat of white wash surfaces of walls all as specified and directed.
Taking up or down 15 mm bore steel tubing and connections.
Taking up or down 20 mm bore steel tubing and connections.
Refixing 15mm bore old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.)
Refixing 20mm bore old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.)
S & F 15 mm bore Galvanized Steel tubes, medium grade with all fittings for water supply pipes fixed to walls or laid in trenches .
S & F 20 mm bore Galvanized Steel tubes, medium grade with all fittings for water supply pipes fixed to walls or laid in trenches .
M/s Paramount Association of India (BID ID -3367650)
M/S MURPHEW ENTERPRISES (BID ID -3372173)
D.P. Traders (BID ID -3373168)
M/s 99 Enterprise of India (BID ID -3373135)
M/S HIGHLANDERS ASSOCIATE OF HIMALAYAS (BID ID -3373194)
M/S ASHOK CONSTRUCTION (BID ID -3373031)
M/S N D ENTERPRISES (BID ID -3372707)
M/S DK TRADERS (BID ID -3374154)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .