Loading…
Loading…
Tender Value
₹27.0 L
EMD Value
₹53,992
Closing Date
1 Sept 2026, 3:00 pm4d left
EE,ELD-9,DDA
EE,ELD-9,DDA
Repair works of street lights on approach roads from heliport road UER-II to the District Centre, Sector-23, Rohini.
2026_DDA_923741_1
22/EE/ELD-9/DDA/NIT/ 2026-27
Open Tender
Electrical Works
Works
30 days
ROHINI
Please refer Tender documents.
11 documents required · 11 mandatory
₹0
₹53,992
27 Aug 2026
27 Aug 2026
2 Sept 2026
27 Aug 2026
1 Sept 2026
27 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing 2mm CRCA sheet powder coated fitting to window opening and fixing on existing 12 mtr poles and also supplying and fixing bakelite plate of size fitting at space in window with connector 32A 2Nos. SPMCB and special bolts opening with allen key i/c testing, commissioning etc. complete as required. | - | Job | 2,436 | - |
| 2 | Providing 2mm CRCA sheet powder coated fitting to window opening and fixing on existing 9 mtr poles and also supplying and fixing bakelite plate of size fitting at space in window with connector 32A 2Nos. SPMCB and special bolts opening with allen key i/c testing, commissioning etc. complete as required. | - | Job | 2,210 | - |
| 3 | Providing of GI sleeve on connector box of 9 mtrs high octagonal pole, made of 3 mm thick MS sheet 250 mm wide duly welded with existing connecter box cover of pole as required | - | Job | 1,439 | - |
| 4 | Providing of GI sleeve on connector box of 12 mtrs height octagonal pole, made of 3 mm thick MS sheet 250 mm wide duly welded with existing connecter box cover of pole as required | - | Job | 1,593 | - |
| 5 | Reparing of damaged/unfinished existing pole foundation of size 1000 mm X 650mm X100 mm using CC work and coating of cement upto the satisfaction of engineer-in-charge complete as required | - | Job | 1,234 | - |
| 6 | Supplying and drawing 3 x 1.5 sq. mm FRLS PVC insulated Copper Conductor, Single Core Cable in the Existing Surface/ Recessed Steel/ PVC Conduit as required. | - | Meter | 104 | - |
| 7LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P.F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K/6500°K(As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.(Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). | |||||
| 7.01 | 72 W | - | Each | 2,128 | - |
| 7.02 | 120 W | - | Each | 2,958 | - |
| 8 | Providing,fabricating,repairing of street light control panels at various locations attached i/c works of CRCA sheet 2 mm thickness,cutting,bending,powder coating,hinges,onsite welding & fixing,panel locks, suitable qty, of DIN Bar channel/MCBs/leads/wires/G.I.nuts.bolts,washers,aluminium strip for earthing upto the satisfaction of engineer-in-chrage etc.testing and commissioning complete as required i/c rebate for dismantled material. | - | sq. ft. | 1,087 | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.30 MB
BOQ_970716.xls
BOQ • 0.29 MB
NIT22.pdf
Tender Documents • 1.92 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].