Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹79.6 CrAccepted-Finance | ₹79.6 Cr | L1 | Accepted-Finance Accepted for further process |
| 2 | L2₹85.3 CrRejected-Finance THIRD FLOOR AMIT CRYSTAL SENAPATI BAPAT ROAD PUNE 411 016 | PUNE | PUNE | MAHARASHTRA | 411016 | ₹85.3 Cr | L2 | Rejected-Finance Rejected as not quoted Lowest. |
| 3 | L3₹86.3 CrRejected-Finance | ₹86.3 Cr | L3 | Rejected-Finance Rejected as not quoted Lowest |
Tender Value
Refer Docs
EMD Value
₹80 L
Closing Date
22 Feb 2024, 3:00 pmClosed
Manager-Admin (Purchase)
CDAC Innovation Park, Panchavati Pashan, Pune 411 008
INTEGRATED CONSTRUCTION OF ACADEMIC BUILDING AT CHIKHALI CAMPUS, CDAC, PUNE
2024_DIT_792279_1
CDACP/LB-ABAC-PH1/23-24/400
Open Tender
Civil Works - Buildings
730 days
Pune
Please refer Tender documents.
2 documents required · 2 mandatory
₹11,800
CDAC
₹80 L
CDAC IP Pune
30 Apr 2024
25 Jan 2024
22 Feb 2024
25 Jan 2024
22 Feb 2024
15 Feb 2024
26 Jan 2024 - 6 Feb 2024
7 Feb 2024
Amount
PLUMBING
Providing, Fixing,testing and commissioning of Sanitary fixtures & CP fittings including all accessories (ISI- marked , sample to be approved from client). The contractor rates to include for supply all Sanitary fixtures & CP fittings including fixing/supporting accessories like WC pan connectors, nuts, bolts, screws, hangers,bottle traps, rubber buffers, CI or MS brackets, anchor fastners, sealents, washers, adhesives,Flanges, plumber's tape, white cement, masking tape (if required for protection),clamps,m.s angles for support etc which are required for the successful installation of the fixtures/fittings including the steel shuttering in a neat workman like manner to the satisfaction of Project Manager.
Rates are inclusive of Providing ,fixing ,testing and commissioning of Sanitary fixtures & CP fittings with all accessories at all the heights, depths and locations within the project premises.
Rates are inclusive of Providing ,fixing ,testing and commissioning for underslung plumbing system or embeded piping, including all clamps & hooks including their painting to complete the work.Mostly, all the toilets in the residencial units have been designed for under slung piping.
Rates are inclusive of provision of extension piece for final connection of CP fitting shall be supplied and installed by the contractor accordingly (as required)
All pressure pipe will be tested on 1.5 times of the working pressure or as per CPWD specifications.
SUB HEAD - I - SANITARY FIXTURES & FITTINGS: Consider all plumbing fixtures with following flow-rates at 3.1 bar or 45 psi pressure.
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:
White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 2 litre/ 4 litre, including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. Notes:- The Flow rate of fixture shall be 1.5 LPM
Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. Notes:- The Flow rate of fixture shall be 1.5 LPM
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing, Fixing,testing and commissioning of 15 mm dia CP brass two way bib cock with flow 4 LPM (Litre per Minute) at 3.1 bar or 45 psi test pressure with C.P. wall flange of approved quality as approved by architect and complete in all respect.
Providing & fixing S.S. health faucet for ablution with 1.2 meter long PVC tube with flow 4 LPM, hand shower, couplings, wall hook and other accessories of quality and make as approved by architect.
Providing and fixing Push stop cock 15 mm nominal bore. Weighing not less than 85 gms.
Estylo Full Brass Auto Push Pillar Cock/Auto Push Faucets/Push Button Taps (Chrome Finished) Heavy Quality(1955) with flow 4 LPM
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.
15 mm nominal bore
Providing and fixing toilet paper holder :
C.P. brass
Providing and fixing uplasticised PVC connection pipe with brass unions :
30 cm length 15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
15mm nominal bore
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
Semi rigid pipe 32 mm dia
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing PTMT liquid soap container 109 mm wide, 125mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
Providing and fixing brass bib cock of approved quality :
15 mm nominal bore
SUB HEAD - II - COLD / FLUSHING WATER SUPPLY (INTERNAL):
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc. 20 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall
20 mm nominal outer dia Pipes
25 mm nominal outer dia Pipes
32 mm nominal outer dia Pipes
40 mm nominal outer dia Pipes
50 mm nominal outer dia Pipes
65 mm nominal outer dia Pipes
80 mm nominal outer dia Pipes
Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends)
32 mm dia, nominal bore
40 mm dia, nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
20 mm nominal bore
25 mm nominal bore
Providing and fixing gun metal non- return valve of approved quality (screwed end) :
50 mm nominal bore Horizontal
65 mm nominal bore Horizontal
BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot eater circulation as specified
80 nominal bore
65 nominal bore
50 nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.
25 mm dia nominal bore
32 mm dia nominal bore
40 mm dia nominal bore
50 mm dia nominal bore
65 mm dia nominal bore
80 mm dia nominal bore
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design :
With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :
With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :
25 to 40 mm nominal bore
50 to 80 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Supplying, fixing,testing and commissioning of storage type waer heater(Geyser) etc. with outer body of ABS, 2MM Thick Mild Steel Inner Tank with glass line coating, option of 1/2/3 KW electrically operated single phase 230V, including Glass Lined Double Heating Element, Digital Display, Multifunction Safety Device, ELCB,Anode Rod System and Brackets For fixing on wall withconnecting Wire & plug etc. conforming to IS:2082 and energy efficient star rated model. Note:- geyser shall be BEE 5 star rated type.
6 Litre capacity
Supplying, Installation, testing and commissioning of water cooler full SS body from front externally connected with water cooler with minimum 60 LPH cooling capacity and having 120 Ltrs water storage tank capacity with multiple function of cooling. Dimension :-700x540x1160mm Weight :-57Kg
Supply & Installation of SOVISY - SMC Panel Tank confirming to: IS 14399 (Part 1& 2): 1996 & IS 4249 :1967 (50mm Insulated )
SUB HEAD - III - INTERNAL DRAINAGE (SOIL, WASTE & VENT):
Providing, jointing, testing and fixing UPVC Soil, Waste & Vent system Class Bconforming to IS : 4985-1983 and UPVC fittings (moulded as well as fabricated) like bends, tees, Y-tees, crosses, boss connections, access pieces, saddle pieces, cleanouts, adaptors for connections to other materials, plugs, reducers, cowls, offset and other specials. Jointing shall be done with pushfit EPDM ring jointing technique in general. Solvent cement joints may be provided for fittings and specials which are not manufactured with pushfit rubber joints.Fixing at wall/ceiling level supported by galvanized steel clamps & hangers etc. Making proper connection and also pipes may be laid / fixed in sunken floors, under slung from ceiling. The pipes laid in sunken floor shall be encased with not less than 75 mm thick cement concrete (1:2:4) all around.The installation shall be complete in all respects including cutting chases / holes in walls, slabs and making good the same as per specifications. (All major MS structure to hold the stack is included in this item) as approved by architect and complete in all respect.
110 OD Type B
Providing, fixing, jointing, testing and commissioning UPVC (Class B) Rain water downtake pipe conforming to IS:13592 cut to required lengths including all necessary fittings and specials.UPVC fittings (moulded as well as fabricated) like bends, tees, Y-tees, crosses, boss connections, access pieces, saddle pieces, cleanouts, adaptors for connections to other materials, plugs, reducers, cowls, offsets and other specials. Fixing at wall/ceiling level supported by galvanized steel clamps & hangers etc. Making proper connection with cement solvent joint as per BIS / manufacturer. Cutting, chases / holes in floors / walls / slab and making good wherever required. (All major MS structure to hold the stack with fixing including anchor fasteners,sand, cement etc is included in this item).
160 mm dia
110 mm dia
Providing, fixing, jointing and testing UPVC soil, waste, vent pipework comprising UPVC pipe conforming to IS :4985-1983 of class 3 ( 6kg/cm2) as specified below and fittings (moulded as well as fabricated) like elbows, bends, reducers, threaded tail pieces, caps, suitable elbow with suitable extension piece for drain point and other specials jointing with cement solvent, chasing, cutting and making good the walls & floors pipes laid in floors shall be encased with 40 mm thick concrete all around, complete in all respects including testing of complete installation.(All major MS structure to hold the stack with fixing including anchor fasteners, sand, cement etc is included in this item) as approved by architect and complete in all respect.
40 mm dia 6 kg/cm2 (Class III )
50 mm dia 6 kg/cm2 (Class III )
Providing and fixing UPVC/SWR trap (P trap) of self cleaning design as per IS:13592 : 1992 complete including cost of cutting and making good the cutouts in walls and floors etc.including cutting and making good the walls and floors wherever required complete as approved by architect and complete in all respect. as approved by architect and complete in all respect.
110 mm inlet and 110 mm outlet
Providing and fixing floor drain made out of 110x63 mm OD uPVC. elbow connected to uPVC pipe complete as per direction of Project Manager as approved by architect and complete in all respect as approved by architect and complete in all respect.
Providing and fixing Inlet Fitting for Urinal trap, formed out of 110 mm PVC pipe with multiple side inlets formed with saddle pieces, suitable for 40, 50 and 63 mm dia side connections as per standard detail and support through galvanized steel support from slab or set in cement concrete mix 1:2:4 including cutting and making good the walls and floors wherever required as approved by architect and complete in all respect..
Providing and fixing Inlet Fitting for floor trap, formed out of 110 mm PVC pipe with multiple side inlets formed with saddle pieces, suitable for 40, 50 and 63 mm dia side connections as per standard detail and support through galvanized steel support from slab or set in cement concrete mix 1:2:4 including cutting and making good the walls and floors wherever required as approved by architect and complete in all respect..
Providing and fixing Heavy Class SS grating of approved design including setting in floor with cement motor to match with floor finish as per architect requirement suitable for waster and FT, UT & FD as approved by architect and complete in all respect..
Size 100 mm X 100 mm
Providing and fixing P.V.C. WC connector (straight or bend type) with rubber lip ring. Including 110 mm dia PVC pipe / bend of required length and proper connection with M seal to C.I. pipe complete as required as approved by architect and complete in all respect..
Providing and fixing cleaning eye 110mm dia on horizontal UPVC soil & waste pipes of 300 mm long UPVC pipe with one plain end lead caulked in to the collar of UPVC pipe and the other end with flange which in covered by neoprene rubber gasket and blank flange, complete with nuts, bolts etc and hot dip galvanization after fabrication to the satisfaction of Project Manager as approved by architect and complete in all respect..
100 mm dia
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
SUB HEAD - IV - EXTERNAL SEWAGE / STORM WATER DRAINAGE :
DWC ID SN-8 & SN-4 Pipe(HDPE Black Pipe) with Coupler & Rubber Ring as per IS:16098(PART 2)
150 mm Dia
200 mm Dia
250 mm Dia
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
150 mm dia. R.C.C. pipe
200 mm dia. R.C.C. pipe
250 mm dia. R.C.C. pipe
300 mm dia. R.C.C. pipe
450 mm dia. R.C.C. pipe
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
100x100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design :
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) :
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra for depth for manholes : Size 90x80 cm
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, outside plastering with cement mortar 1:3(1 cement : 3 coarse sand), foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :
0.91 m deep with SFRC cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering , excavation, refilling, disposal of surplus earth in all kinds of soil, footrest etc. all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be including in this item.) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 m
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :
For pipes 100 to 250 mm diameter
For pipes 250 to 300 mm diameter
Providing, laying and making kerb channel 30cm wide and 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth etc. complete as per direction of Engineer-incharge.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
SUB HEAD-V-TUBEWELL AND TUBEWELL PUMPS Note: The quantities may varies as per site conditions.
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. All types of soil
300 mm dia
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineerin-charge.
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge. (Quantity of pipes of indicated in quanty is indicative. Exact depth will be ascertened as per water aquifer of site)
200 mm nominal size dia having minimum wall thickness 5.40 mm
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge. (Quantity of pipes of indicated in quanty is indicative. Exact depth will be ascertened as per water aquifer of site)
200 mm nominal size dia
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. (Quantity given is indicated in quantity is indicative. Exact time of development quality of water aquifer of site)
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:
200 mm clamp
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.
200 mm clamp
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).
200 mm clamp.
SUBHEAD - VI - WATER SUPPLY, DRAINAGE, PUMPS & EQUIPMENT
Providing and fixing of package type skid mounted hydropneumatic system comprising of as approved by architect and complete in all respect.
Horizontal / Vertical inline single/multistage centrifugal pumping set with stainless steel SS stage casing and SS impellers with stainless steel shaft, cast iron suction & discharge casing, connected to suitable capacity TEFC ventilated induction motor 2 pole, 2900rpm, suitable for 415±10% Volts, 3 phase, 50 Hz A.C. supply.
Pressure vessel of non corrosive FRP composite construction lined with NSF and/or FDA listed material, like high density polyethylene with fully replaceable polyurethane. Air cell burst pressure of minimum of 5 times the vessel operating pressure and cycle tested for 2,50,000 cycles.
No. and capacity of Pressure Vessel - 01 No. x 100 Ltrs.
Electronic Pressure switches having maximum pressure and differential scale should confirming BS-6134 standards and IP55 protection class.
Complete set system to be mounted on a common MS base frame and shall follow following duty.
The cost will include making necessary flanged suction and delivery headers in GI (C class)
Motor to be of the same make as the pump
(Vendor to submit performance curves and technical catalog of the proposed model for review & information)
Domestic Pump Capacity : 280LPM Each Pump (1 Working + 1 Standby) @ 45 M head. (location at UGT Plant room) as above
Flushing Pump Capacity : 185 LPM Each Pump (1 Working + 1 Standby) @ 45 M head. (location at STP room)as above
Soft Water Pump Capacity : 42 LPM Each Pump (1 Working + 1 Standby) @ 45 M head. (location at UGT Plant room)as above
Supply, assembly, erection, testing and commissioning of pumping system comprising the following: as approved by architect and complete in all respect. Vertical/Horizontal centrifugal pumps (1 Working + 1 Stand-by) with mechanical seal, SS Volute casing and SS impeller connected to suitable capacity TEFC induction motor suitable for 415 ± 10 % volts, 3 phase, 50 cycles A.C. supply with 100 mm dia. pressure gauges including MS skid and mounting of the pumps on the skid. (Motor to be of the same make as the pump)
Raw Water Filter Feed Pump : Capacity : 186 LPM Each Pump (1 Working + 1 Standby) @ 30 M head. (location at UGT Plant room)
Soft Water Filter Feed Pump : Capacity : 183 LPM Each Pump (1 Working + 1 Standby) @ 30 M head. (location at UGT Plant room)
For tube well water supply Capacity : 467 LPM Each Pump (1 Working) @ 118 M head (location in tube well).
Supply, assembly, erection, testing and commissioning of SS/CI submersible grinder type pumps, suitable to handle basement drainage having the following capacities, complete with 3 phase squirrel cage submersible motor of required HP for 415 ± 10% volts, 3 phase, 50 Hz. A.C. supply cooled by surrounding liquid, submersible cable upto main panel within the plant room, dry running preventor, G.I. guide pulling chain, all the necessary piping and accessories, valves, delivery header etc. as required complete in all respects. The rate will include electrical panel with cyclic operation as supplied by the manufacturers. The rate will also include a three level sensor, controller and level indication (low, mid and high) system with a sounder for high level. The pumps will start as follows: (a) At mid level pump 1 will start. (b) At high level pump2 will start and there will be a sounder alarm as approved by architect and complete in all respect. The above installation shall be complete with sump pump lifting assembly, ready made electro – galvanized MS lifting chain, GI pipe header complete with discharge manifold, flanges, tee, elbow etc. complete including GI pipe upto the top of sump and including GI union. Header shall be sized for both pump working under delivery velocity of 1.5 m/sec.
Capacity of 216 lpm against a total head of 20m (solid handling 20 mm) (Pump room drainage) (1 Working + 1 Stand by) (SS Body and SS Impeller and shaft)
SUBHEAD - VII - WATER TREATMENT PLANT
MULTIGRADE SAND FILTER (For Domestic/soft supply) Supply, installation, testing & commissioning of vertical self supporting Dual Media Filter (DMF) fabricated from FRP as per IS : 2825, ASMI code, complete with pressure gauges at inlet & outlet, sample cock, PVC face piping with ABS multiport valves and all accessories, with initial charge of filter media for Dual media filter with multi grade quartz sand & anthracite, lining inside with PP and FRP wounded outside, testing and commissioning complete as approved by architect and complete in all respect.. a) Capacity : 117 lpm b) Filtration rate : 13.93 M³/M²/hr c) Max. operating pressure : 3.5 Kg/Sq.cm d) Test pressure : 5.5 Kg/Sq.cm
ACTIVATED CARBON FILTER (For Domestic/soft supply) Supply, assembly, erection, testing & commissioning of vertical M.S. Activated Carbon filter fabricated from 6mm thick M.S plate shell and 8mm thick M.S. plate dished ends with 3mm non-toxic, non-leaching rubber lining (rubber lining to be tested for pin-holes by spark tester) inside complete with initial charge of filter media activated carbon, face piping (GI, C Class), diaphragm/ball/non-return valves, accessories, painting, testing and commissioning of any under drainage system as required, complete. (Tested to 10 kg/sq cm) as approved by architect and complete in all respect. Capacity : 117 lpm Filtration rate : 13.93 M³/M²/hr Max. operating pressure : 3.5 kg/Sq.cm Test pressure : 5.5 Kg/Sq.cm
Supplying, installing, testing and commissioning electronic chlorine solution dosing system comprising of F.R.P/ chemical grade HDPE solution tank of 200 litres capacity electronic dosing pump of capacity 0-4 LPH against 4.5 Kg/Sq.cm dosing valves, flexible teflon tube pipes etc. complete for dosing of chlorine solution into water on line.
Supplying, assembly, erection, testing and commissioning of magnetic level sensors and controllers, CPVC probe tube, PP actuating float and all other equipment required for the performance of the system to the satisfaction of the engineer in charge complete including providing and fixing wiring from control junction box near the UG tank to probes of required length, interconnection wiring between level controller and the concerned contactor in the starter panel as required. The level controller will perform the following functions as approved by architect and complete in all respect.. a) To switch on the pumps (including tube well pumps 2 nos., raw water pumps, Domestic Water Treatment etc.) To cut off the pump when the level in the receiving water tank is high and switch off the pumps when the level of water in the supply water tank is low. b) To indicate 3 levels of water in all tanks through a control panel with LEDs c) To start the pumps in a cyclic order. The system shall be complete to ensure automatic quotation of pump in accordance to water level in respective tanks. The Contractor will include all the under ground and over head tanks and all the pumps as required for level control in this item
Providing & fixing Electric control panel to open / close the solenoid valve at low / high water level through level controller in OH water tanks including wiring, level controller probes & other accessories as required to operate the system automatically, including providing motorized butterfly valves with weather proof enclosure valves of suitable size as approved by architect and complete in all respect..
"Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :" "Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture"
Supply, installation, testing and commissioning of tanker inlet connection complete with 80 mm dia GI inlet piping, hose inlet connection, MS cabinet enclosure (epoxy painted after fabrication), pad locking arrangement, inlet flexible hose complete with all necessary arrangementas approved by architect and complete in all respect..
Providing & fixing C.I. 'Y' Strainer (screwed / flanged) with stainless steel fine wire mesh perforated sheet basket with necessary flanges / union nuts, bolts & washers complete as required (on pump suction)as approved by architect and complete in all respect. 80 mm dia
SUBHEAD -VIII - MISCELLANEOUS ITEMS
Providing and fixing M.S. puddle flanges (fabricated of 750 mm long pipe pieces) to R.C.C. water tanks wall / slab. The entire fitting shall be hot dipped galvanized (Flanges shall confirm to BS10 Table E) as approved by architect and complete in all respect..
25 mm dia (Screwed ends MS plate 6 mm thick; 100 mm x 100 mm plus dia of pipe).
40 mm dia (Screwed ends MS plate 6 mm thick; 100 mm x 100 mm plus dia of pipe).
50 mm dia (Flanged ends MS plate 6 mm thick; 100 mm x 100 mm plus dia of pipe).
65 mm dia (Flanged ends MS plate 6 mm thick; 100 mm x 100 mm plus dia of pipe).
80 mm dia (Flanged ends MS plate 6 mm thick; 100 mm x 100 mm plus dia of pipe).
100 mm dia (Flanged ends MS plate 6 mm thick; 100 mm x 100 mm plus dia of pipe).
150 mm dia (Flanged ends MS plate 6 mm thick; 100 mm x 100 mm plus dia of pipe).
Providing and fixing Expansion flexible bellows between existing puddle flange in water tank retaining wall and proposed puddle flanges as mentioned under item No. 3 above. The bellow flanges shall match with exiting puddle flanges at site as approved by architect and complete in all respect.
50 mm dia
65 mm dia
Providing and fixing in position G.I. vent with brass mosquito proof coupling and air filter including return bend, complete as required. The entire fitting shall be hot dip galvanizedas approved by architect and complete in all respect.
100 mm dia
Providing, testing & commissioning of dial type pressure gauge with pressure scale of 0 to 15 kg / cm2. Provision of isolation cock suitable for pressure of 15 kg / cum2 shall be included in cost.
Supply complete testing kit with all chemicals complete suitable for conducting test on water quality. The test kit shall be suitable to measure TDS, pH, Hardness, Iron content and other parameters (Make : Ion Exchange)as approved by architect and complete in all respect..
Providing & fixing in position Vane Type mechanical water flow meter for following pipe sizeas approved by architect and complete in all respect..
UPTO 50 mm dia
50- 80 mm dia
Providing, fixing, testing and commissioning of Air Release Valves screwed ends with ball valve of approved brand of manufacture, with accessories etc., complete.
25mm dia
CIVIL WORK
EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.
Ordinary rock
Hard rock (blasting prohibited)
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.
All kinds of soil (From 1.50 to 3.00 mtr)
From 3.00 to 4.50 mtr
From 4.50 to 6.00 mtr
Supplying and filling in plinth with local sand under floors, including watering, ramming, consolidating and dressing complete.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
Supplying chemical emulsion in sealed containers including delivery as specified.
Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for POSTCONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete:
With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor :
With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All Kinds of soil
Pipes, cables etc, not exceeding 80 mm dia.
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
Stripping of 6-8 inches of top soil , maintaing and filling it back during final landscaping
CONCRETE WORK
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shttering - All work up to plinth level
1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size).
1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing :
1:1½:3 (1 cement : 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
Extra for providing and mixing water proofing material in cement concrete work @ 1 kg per 50kg of cement.
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
REINFORCED CEMENT CONCRETE
Centering & shuttering including strutting, propping etc. and removal of form work for
Foundations, footings, bases of columns, etc. for mass concrete
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platform.
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Columns, Pillars, Piers, Abutments, Posts and Struts
Stairs, (excluding landings) except spiral-staircases
Edges of slabs and breaks in floors and walls Under 20 cm wide
Steel reinforcement for R.C.C. work ncluding straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose.(2) The payment will be made once only for execution of all items for such works.
Design Mix Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.( minimum 40% opc cement ) All works upto plinth level
Concrete of M25 grade with minimum cement content of 330 kg /cum
Concrete of M30 grade with minimum cement content of 350 kg /cum
All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum
Concrete of M30 grade with minimum cement content of 350 kg /cum
Concrete of M40 grade with minimum cement content of 390 kg /cum
Add for using extra cement in the items of design mix over and above the specified cement content therein.
Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete in lintels, beams and bressumers, including setting in cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering and shuttering but , excluding the cost of einforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) .( minimum 40% opc cement )
Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 6mm nominal size ), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits
40 mm thick
Providing and fixing Rebar couplers of different thickness to join TMT bars of dia more than 25 mm confirming to all IS code and BIS standards.
25 mm dia
32 mm dia
40 mm dia
BRICK WORK
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) With F.P.S.(non modular) bricks
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.
Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand).
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry
CLADDING WORK
Providing and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with (machine cut edges) of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately).
Red sand stone - 30mm thick gang saw cut stone
White sand stone - 30mm thick gang saw cut stone
Extra for stone work for wall lining on exterior walls of height more than 10 m from ground level for every additional height of 3 m or part there of.
Height 10 to 13 mtr
Height 13 to 16 mtr
Height 16 to 19 mtr
Height 19 to 22 mtr
Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, welding etc. The frame work shall be fixed to the wall with the help of M.S. brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in brick wall with cement concrete block 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) of size 300x230x300 mm, including cost of necessary centring and shuttering and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to support stone cladding, the steel work will be given a priming coat of Zinc primer as approved by Engineerin- charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-in-charge for approval before execution). The frame work shall be fixed in true horizontal & vertical lines/planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall be paid).
Providing and fixing cramps of required size & shape in RCC/ CC / Brick masonry backing with cement mortar 1:2 ( 1 cement :2 coarse sand), including drilling necessary hole in stones and embedding the cramp in the hole (fastener to be paid separately). Stainless steel cramps
Stone work, plain in copings, cornices, string courses and plinth courses, upto 75 mm thick in Cement mortar 1:6 (1 cement : 6 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. Red Sand Stone
Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. Red sand stone
Providing wet cleaning of stone cladding with High Pressure Jet with minimum 120 bar pressure to wipe out foreign particles on the surface and then allow the surface to dry for at-least 24 Hours .As a second step, providing and applying “ Anti- Fungal Water Repellent Coating ” consisting of silane siloxane of BRAND KONEX WRA 2318 on the stone cladding by spraying complete in all respect and heights over dry stone cladding.
MARBLE & GRANITE WORK
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab over 0.50 sqm
Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete.
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc.complete.
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
Marble work
Granite work
Providing and making V groove in granite steps for staircase , treads etc. complete as per design approved by Engineer-in-Charge.
WOOD WORK
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).
Saal wood
Kiln seasoned and chemically treated hollock wood
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) One Side only
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of doorshutter to be measured).
Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : 2nd class teak wood 50 x 20 mm
Providing and fixing teak wood lipping of size 25x3 mm in pelmet.
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed onthe body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady] the frame.
Providing and fixing to existing door frames. 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.
Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete.
uPVC Providing and fixing factory made uPVC white colour casement/ casement cum fixed glazed windows comprising of uPVC multichambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable
Casement window single panel with S.S. friction hinges (300 x 19 x 1.9 mm), made of (small series) frame 47 x 50 mm & sash 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glass pane glazing bead of appropriate dimension. (Area of window upto 0.75 sqm.)
Casement window double panels with S.S. friction hinges (300 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window above 0.75 sqm upto 1.50 sqm).
Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 2.50 sqm).
Providing and fixing in wall lining medium density fibre board IS: 14587:1998 marked, Pre-laminated with one side decorative lamination and other side balancing lamination, with necessary fixing arrangement and screws etc. all complete. 12 mm thick
Providing and fixing wooden moulded corner beading of triangular shape to the junction of panelling etc. with iron screws, plugs and priming coat on unexposed surface etc. complete 2nd class teak wood. 50x50 mm (base and height)
Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/m²) suitable for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulation having density min 96Kg/m³ . The frame will have a provision of G.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter. The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded).
Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634- 1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 kg/m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge (panelling to be paid for seperately).
Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per direction of Engineer-in- charge. The glass shall be clear, toughened, interlayered, non-wired fire resistant having 11 mm thickness of approved brand with 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 15 min of insulation (EI15) and having a sound reduction of 37dB and LT of 86%. Glass shall be compliant to class 2(B)2 category of Impact Resistance as per EN 12600. The glass should be manufactured in UL & TUV audited Facility and including UL-EU Certification.The maximum glazing size cannot be more than 1100 mm x 2200 mm (w x h) or 2.42 sq mts in total area. The test report for the complete system (Glazed Door or Partition) will be considered valid only if it contains the stamp and signature of the authorized signatory from the glass manufacturer. (Actual glass size is to be measured at site for payments)
Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured).
Extra if louvers (not exceeding 0.2 sqm) are provided in flush door shutters (overall area of door shutters to be measured). Decorative type door
FIRE RESISTANT GLAZED DOOR SYSTEM WITH UNIFORM SLEEK 50x50 Profiles
Supply and installation of tested fully glazed fire rated unlatched double leaf door sleek uniform profiles system with 120 minutes of integrity and radiation control (EW 120) with symmetrical (Bi-Directional) fire protection. The frames shall be cold rolled profiles as per EN standard EN 10327. The door frames are cold rolled from 1.5 mm steel sheet to form a profile of 50 mm x 50 mm on all sides. The door shutter would have the uniform top rail, side rail and bottom rail dimensions of 50 mm x 50 mm. The overall door opening shall be as per tested evidence and tested as per EN 1634-1/ IS16947/ ISO 834-1 / ISO 3009 in an accredited laboratory.
The glass must be minimum 14mm ( MADE IN INDIA ) clear 120 min fire rated for Integrity, Radiation control (EW 120) and partially insulation (EI 20) Non Wired Toughened Interlayered glass with a light transmission of 86% and a sound reduction of 38 dB and manufactured in UL & TUV audited Facility and including UL-EU Certification( certification copy to be submitted) and compliant to class 1(B)1 category of Impact Resistance as per EN 12600. The glass shall be tested and certified for no formation of bubbles or yellowing after 5000 hours of exposure to UV radiation as per EN 12543-4..The glass shall provide bi-directional (Symmetrical) fire protection .The base glass for the interlayer Fire glass must bemade in India and with ISI mark as per IS 2553
The shutters should be fixed to the frame using Weld-on hinges of dimensions 179mm X 20mm . The profiles shall have groves to incorporate Fire Resistant gaskets. The glass should be held in its place with the help of 1.5 mm cold rolled steel beading and Kerafix 2000 ceramic tape with cross section of 4 x 15 mm as per the test evidence. Beading shall be clipped on using Stainless Steel self-tapping screws fixed at a distance of 70 mm from the edges and 150 mm c/c henceforth. The glass panes are to be supported on non-combustible 6 mm Calcium Silicate setting blocks. The door should be fitted with offset pull handle and door closer of Dorma (TS 73V, TS 83V, TS93V), Geze (TS 2000NV) or equivalent. The inactive leaf should be fixed to the frame using a tower bolt at meeting edge at top or as per the tested evidence. The doors shall be manufactured in a TUV audited facility and shall be of Saint Gobain or as per in approved make list complying to the above specification . The maximum glazing size shall be as per the test certification. The profile has to be fixed to the supporting construction by means of M10 or bigger steel bolts at every 150 mm from the edges and every 500 mm (approx.) c/c. The door shall also be subjected to durability tests as per EN 12400 for minimum C5 classification (200,000 cycles) tested.
Fire Rated Door Makes- Saint Gobain, Acodor , Matrix, Godrej Fire Rated Glass - Saint Gobain, Trosch , Pilklinton , TGP The test report will be considered valid only if it contains the stamp and signature of the authorized signatory from the supplier. DOOR SYSTEM SIZE: W X H In mm
2000X2400 AS ABOVE
1500X2400 AS ABOVE
1200X2400 AS ABOVE
ELECTRICAL SHAFT DOOR Providing and fixing of approved or equivalent make HMPS doors. Doors should be finished in Powder Coating with film thickness of 60 microns approx. in desired RAL Shades. The manufacturer company must be ISO 9001-2015 certified. Door frame is Single rebate profile of minimum size 100mm X 57 mm made out of 1.5 mm minimum thick galvanized steel sheet. Aco100 profile of 100x57 Frames wshall be Mitred jointed and field assembled with mitred joint. The frames is finished with Powder Coating in desired RAL Shade. Frame having provisions and necessary reinforcement for receiving appropriate hardware like lock and hinges. Frames will be provided with back plate bracket to receive anchor fasteners for installation on a finished plastered wall opening. Door leaf shall be manufactured from 0.8 mm thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be honey Comb craft paper. All Acodor steel doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement . Vision lite wherever applicable should be provided as per manufacturers recommendation and desired to be fixed with 'Z' clipping on system or double glazed glass .
Providing & Fixing of Fabric Blinds for all windows at all heights with translucent fabric & 100% Polyster woven with .40 mm thickness & conditionally cleanable as approved by architect and complete in all respect.
Providing & fixing of Roller Blinds (Blackout) on the windows at all heights, as approved by architect and complete in all respect. Note:- The blind is 100% Polyster with thickness of 0.45 mm
Providing & fixing of wooden Blinds for all windows with 35 mm to 50 mm wide with mechanism in which lifting & tilting is done by same cordian as approved by architect and complete in all respect.
providing & Fixing of Roman Blind for all windows with 0.40 mm thickness and one touch down system with one cord and suitable for Moist environment as approved by architect and complete in all respect.
Providing & Fixing ofRooler Blind Perforated Screen Fabric on the windows at all heights as approved by architect and complete in all respect.
GLASS WORK
Supply and installation of SGIPL Clipper Sleek Series for minimal frame, room dividing solutions. Single glazed demountable glass partition using clear toughened glass in proprietary natural anodized/black aluminum sections Clip- on / U-Section of size 30mm x 21mm with suitable gaskets for insertion with glass. It also consists of clipper two way profiles, 90 Degree L Junction and T Junction profiles suitably to be used as per room configuration designs. Glass thickness - 10mm( LSG). All Profiles are min 2.5mm thickness excluding 20 microns of Anodizing, Standards applicable • Aluminium profile made by Al Alloy 6063-T6 grade ( Make : Saint Gobain, Jeb, Alloy and Dorma)
Door - 1200mm -Single Door- W1200mmx H2400mm Clipper Sleek Series System for 70x45mm Stile door. ( Make : Saint Gobain, Jeb, Alloy and Dorma)
Door - 1000mm - Single Door- W1000mmx H2400mm Clipper Sleek Series System for 70x45mm Stile door. ( Make : Saint Gobain, Jeb, Alloy and Dorma)
Providing & Fixing Stainless Steel Indicating Bolt & Dead Bolt, SS Plate Black Body with SS Finish Lock as approved by architect and complete in all respect.
Providing & Fixing Mortise handle in SS304 Pipe with 22mm dia & latch with SS Front & Strike Plate as approved by architect and complete in all respect.
Providing & Fixing Mortise handle in SS304 Pipe with 22mm dia & latch with SS Front & Strike Plate as approved by architect and complete in all respect.
Providing & Fixing Mortise handle in SS304 Pipe with 22mm dia & latch with SS Front & Strike Plate as approved by architect and complete in all respect.
Providing & Fixin Pull & Mortise handle in SS304 Pipe with25mm & 22mm dia respectively + lockbody with SS Front & Strike Plate, Heavy Duty Springs, Anti Corrosive Plating, Double Throw Deadbolt, Brass follower for mortise rod + 5 Pin Euro Profile Cylinders, 3 Brass Keys, EN Standard, 2 Lakh Cycle Tested as approved by architect and complete in all respect.. 10"x25mm Pull / 100 ss 50x85mm / 09 ss 60mm)
Providing & Fixin Pull & Mortise handle in SS304 Pipe with25mm & 22mm dia respectively + lockbody with SS Front & Strike Plate, Heavy Duty Springs, Anti Corrosive Plating, Double Throw Deadbolt, Brass follower for mortise rod + 5 Pin Euro Profile Cylinders, 3 Brass Keys, EN Standard, 2 Lakh Cycle Tested as approved by architect and complete in all respect. (100 ss 50x85mm / 09 ss 60mm)
Providing & Fixing Plasma pull handle in SS304, 10" length & 22mm dia as approved by architect and complete in all respect.
Providing & Fixing Redfire pull handle in SS304, 12" length & 22mm dia as approved by architect and complete in all respect.
Providing n& Fixing Heavy Deluxe Tower Bolt (10") in SS304 with Front Fixing Screws as approved by architect and complete in all respect.
Providing n& Fixing Heavy Deluxe Tower Bolt (6") in SS304 with Front Fixing Screws as approved by architect and complete in all respect.
Providing & Fixing Sign Plates 170 mm stainless steel as approved by architect and complete in all respect.
Providing & fixing Double door Lock with cylinder 10 to 12 mm Glass Left,right complete as approved by architect and complete in all respect.
STEEL WORK
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position andmapplying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
FLOORING
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand), laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab of all colour and texture except Black, Cherry/Ruby Red
Extra for pre finished nosing in treads of steps of Kota stone/ local stone slab. (Details As above Refer SR. No.196 )
Extra for Kota stone/ sand stone in treads of steps and risers using single length up to 1.05 metre( Details As above Refer SR No.196 )
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 800x800 mm
Size of Tile 1000 x 1000 mm
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
Glazed vitrified floor tiles polished finish of size
Size of Tile 800 x 1200 mm (Details As above Refer SR. No.201.1 )
Size of Tile 1200 x 1200 mm (Details As above Refer SR. No.201.1 )
Glazed Vitrified tiles Matt/Antiskid finish of size
Size of Tile 1200 x 1200 mm AS ABOVE (Details As above Refer SR. No.201.1 )
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete.
Size of Tile 600x600 mm
Size of Tile 800x800 mm
Size of Tile 1000x1000 mm
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Providing and laying machine cut, mirror polished, Italian Marble stone flooring laid in required pattern in linear portion of the building all complete as per architectural drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm including pointing with white cement slurry admixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 18 mm thick Italian Marble stone slab, Perlato, Rosso verona, Fire Red or Dark Emperadore etc.
52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick
Providing and fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Fibre glass wool conforming to IS : 8183, density 24kg / m3, 50mm thick, wrapped in 200 G Virgin Polythene bags, fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5 mm x 24 gauge wire mesh, for top most ceiling of building.
40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints finished flush. Red sand stone
Floor Carpet Providing and laying machine made woolen carpet (1200gm/sqmt.) of approved sample, shade and of approved manufacturer. The woolen carpet shall be fixed on 12mm thick rubberized coir under layer fixed on floor with rubberized adhesive, ends of the carpet shall be secured in position with floor by providing necessary wooden nailed beading fixed to floor with necessary adhesives, PVC fasteners and steel screws etc. as per locations shown in architectural drawing for carpet flooring and direction by architect and complete in all respect.
Supply & Fixing Sports Flooring in Play Area includes Shock absorption,Sliding Coeffiecient, impact Resistance Properties or as approved by architect and complete in all respect.
Providing & fixing 12 mm thickness Laminated wooden Flooring with high five resistence, water resistance, scratch resistance and coated with layers of aluminium oxide particles for better strength and durability as approved by architect and complete in all respect.
ROOFING
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing and fixing on wall face unplasticised Rigid PVC rainwater pipes confirming to IS:13592 Type A including jointing with seal ring confirming to IS:5382 leaving 10 mm gap for thermal expansion.(I)single socketed pipes. 110 mm diameter
Providing and fixing on wall face unplasticised PVC moulded fitting acessories for unplasticised Rigid PVC rain water pipes confirming to IS-13592 type A including jointing with seal ring confirming to IS 5382 leaving 10mm gap for thermal expansion. Coupler 110 mm
Bend 87.5* 110 mm bend (Details As above Refer SR. No.217 )
Shoes (plain) 110 mm shoe (Details As above Refer SR. No.217 )
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and erimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
Fully Perforated Gypsum Plaster Board of size 1200 x 2400x12.5 mm having approx. 15 % perforated area with perforation size and pattern as approved by the Engineerin- charge and as per manufacturer's specification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60
Providing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be paid separately): Flat Surfaces
Providing and fixing Gl Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing 'C' wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of Gl steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring T with :
GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation.
Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm ) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised @80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be prepainted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge.
With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6)
Providing & Fixing of Wooden finished Suspended Ceiling System with Woodworks Vector edge tiles with Armstrong 15mm Prelude 43 exposed grid as approved by architect and complete in all respect.
Providing & Fixing of Custom Printed Mineral Fibre Acoustical Suspended Ceiling System with Ultima (Bevelled Tegular) Edge Tiles With Armstrong 15mm Exposed Grid as approved by architect and complete in all respect.
Providing and Fixing Channeled Woodworks perforated panels of width 192mm, thickness of 15mm and length 2400 mm or as required by the Architect/ approving engineer, made of a high density fibre board with minimum 725 Kg/M3 density substrate with a laminated facing as per the approved shade & finish and a melamine balancing layer on the reverse side. The boards shall have a special perforation pattern where the visible surface has a “Helmholtz” fluted perforation of 3mm width and 5mm/13mm/21mm of visible panel each. The edges of the panels shall be “tongue-and-grooved” to receive special clips for installation. The back of the perforated panel shall have sound absorbing non-woven acoustical fleece having NRC of 0.52-0.63. The panels shall be mounted on special aluminium splines using clips provided by Armstrong and as approved by architect and complete in all respect..
Providing and fixing china mosaic tile of 6 - 8 mm for terrace to reduce the heat effect in a pattern as approved by architect and complete in all respect.
Providing fixing thermal insulation of ceiling (under deck insulation)with Resin Bonded Fibre glass wool conforming to IS : 8183, density 24kg / m3, 80 mm thick, wrapped in 200 G Virgin Polythene bags, fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5 mm x 24 gauge wire mesh, for top most ceiling of building.
FINISHING
12 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement : 4 fine sand)
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement : 4 fine sand)
Neat cement punning
Providing and applying 12 mm thick (average) premixed formulated one coat gypsum lightweight plaster having additives and light weight aggregates as vermiculite/ perlite respectively conforming to IS: 2547 (Part - 1 & II) 1976, applied on hacked / uneven background such as bare brick/ block/ RCC work on walls & ceiling at all floors and locations, finished in smooth line and level etc. complete.
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.
Extra for plastering on circular work not exceeding 6 m in radius: In two coat
Extra for plastering done on moulding, cornices or architraves including neat finish to line and level: In two coats
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
6 mm plaster on cement concrete or reinforced cement concrete work with white cement based polymer modified self curing mortar of approved make as per the direction of Engineer-In-Charge.
Finishing walls with 100% Premium Acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
French spirit polishing : Two or more coats on new works including a coat of wood filler
Providing & fixing hexagonal chicken mesh having opening 20mmx20mm of 26 gauge at juncitons of concrete & brick work or between different material etc. as approved by architect and complete in all respect.
Forming groove of uniform size from 12x12mm and upto 25x15mm in plastered surface as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repairs to the edges of plaster panel and finishing the groove complete as per specifications and as approved by architect and complete in all respect.
Controlled Dismantling of 150 MM thik. RCC Slab with Diamond floor Sawing and core
Controlled Dismantling of 450X650 MM thik. RCC Beam with Diamond floor Sawing and core Machine
Stair Case Slab Demolished by Electric Breaker
WATER PROOFING
Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of : Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions. Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer. Using rough kota stone.
Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge : Using rough kota stone.
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, erraces etc consisting of following operations: Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.
Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Eng ineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.
After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.
(Described above)The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete : Serrated with central bulb (225 mm wide, 8-11 mm thick)
Providing and laying terrace garden with water proofing treatment including preparation of surface as required for treatment of roofs, plants and growing medium etc consisting of following operations: (a) Laying Drain cell (500x500x30 mm) over the water proofing compound. (b) Laying a layer of geotextile sheet ( 150 gsm) having non woven property over drain cell. (c) Spreading Cocopeat upto height of 450 mm over the roof & parapet. (d) Spreading & dressing of wormicompost over the roof. (e) Laying a layer of Carpet S-1 (grass including levelling, dressing & handling) over the roof. (f) Supply & Installation of Plants approved by Architect.
Cleaning and Surface Preparation: The cleaning and preparation of the substrate to which waterproofing is applied must be carried out thoroughly to leave a sound base for the application. Any oil, grease, rust, etc. present on the surface must be removed mechanically which otherwise may impair adhesion.Making coving with MasterSeal S 348 as required complete.
Waterproofing Coat : Prior to application of the waterproofing membrane, an epoxy primer MasterSeal P2525 shall be applied over the spray foam insulation at a coverage rate of 0.4 kg/m2. This shall be followed by sprinkling of MasterTop SRA no. 3 @ 1 Kg/sqm over the primed surface to provide for a mechanical key for the subsequent layer. The waterproofing membrane shall beMasterSeal M800, which is a solvent free, two component waterproofing membrane. It is highly reactive and can only be applied by special, two-component spray equipment. The mixed product should have the following features and benefits : (i) Elongation at break as per DIN 53504 shall be 400 %. (ii) Tensile Strength as per DIN 53504 shall be 8 – 10 N/mm2. (iii) Tear propagation resistance as per DIN 53515 shall be 16 N/mm2. (iv) Consumption shall be in the range of 2.1 – 2.2 Kg/m2 to achieve average thickness of 2 mm.
STRUCTURAL GLAZING ALUMINIUM COMPOSITE PANEL
Providing, assembling and supplying vision glass panels (DGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthened clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor.“(Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.25.2)“For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.“
Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approvedmshop drawings , the aluminium quality as per grade 6063 T5 or T6mas per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)- cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:
Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.
Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it water tight.
Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, abour for fabricating and installation of aluminium grid, installation ofglazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified.The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge
The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.
Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places.
Note:- 2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories
(1) Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr. (2)Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. (3)Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml (4) Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm (5)Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test. Tests to be conducted on site. (6)Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml
Work defined as above
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge.
Extra For Toughning Float Glass 6 mm thick as per directed by the Engineer-in-charge.
Providing and fixing ‘UniStone’ Wall Cladding Clay Tiles in Size 230mm x 75mm x 15mm thick in approved natural clay shade or ‘Terracotta’ made from natural clay. The appearance and shade of tiles should be natural terracotta having subtle variation in shade. The tiles would be made from special clay and firing temperature would be more than 1100° Celsius & shall have 1.75mm deep groove at the back side of the tile. The allowed variance in these tiles should not be more than ±2.5mm & top surface should be coated with silicone and surface water absorption should not exceed 2%. The breaking strength of the tile shall be ≥ 20 N/mm² asper DIN – 18166.The product should be applied on cured rough plastered surface. The substrate plaster should be in ratio of 1:3 (Cement: Coarse Sand) & tiles should be applied by an exterior polymer modifiedcementitious tile adhesive having tensile adhesion strength ≥ 2.5 N/mm2 as per EN 1348. The product should be applied with plus shaped spacers in desired groove width i.e. 6-8mm and all grooves horizontal and vertical should be pointed with a mix of fine sand and cement in ratio of (3 parts fine sand and 1 part of cement). All work should be carried out as per manufacturer’s laying instructions. jointing with grey cement slurry @ 3.3kg/sqm including grouting the. joint with white cement & matching pigments & all hieght etc. complete.
Wet cleaning of stone e levation with High Pressure Jet with minimum 120 bar pressure to wipe out foreign particles on the surface and then allow the surface to dry for at least 24 Hours .As a second step, providing and applying " Efflorescence prohibitor , anti fungal water pepellent Coating " consisting of BRAND KONEX WRA 2318 meant for herita ge building and having accreditation of Central Building Research Institute Roorkee on the st one elevation wall by spraying complete in all respect and heights ov er stone elevation .The work would be carried out all complete as per direction of the Engin eer in charge.
MISCELLANEOUS WORK
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately).
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia 4 mm
Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant(Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete.
CARRIAGE OF MATERIALS
Carriage of material by mechanical transport including. Loading , unloading and stacking.
0 km. upto 1 km. (Hard work)
0 km. upto 0.5 km. (Hard rock)
BARRICADING WORK
Providing and erecting 6.00 metre high temporary barricading at site; each panel of size 3.0m x12.0m made of MS Pipe of 80mm dia and 25mm dia posts/horizontal members/bracings covered with 0.3mm thick GI sheet. The sheet shall be fixed with suitable welding/riveting. The panels shall be made so that gap of 50cm above the ground is available making overall height as 12.5 m. Suitable arramgement shall be made to fix the barricading to avoid from overturning by providing 250mm long expansion fastners at both ends. The work shall be executed as per drawing/ direction of Engineer-in-Charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps, reflective signs, marking, flags, caution tape as directed by the Engineer-in- Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Engineer in-Charge. (Note :- One time payment shall be made for providing barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completion of the work).
P. T. Beam
Designing of PT Beams for Gravity Loads and taking approval of the same from Structural Consultants. (BONDED & UNBONDED PT SYSTEM) Providing, supplying and executing Post Tensioning works with 12.9mm/15.2mm dia. H. T. Strand (Make: Tata, Usha Martin, Kataria , JSW, D. P. Wires or equivalent with prior approval of the Engineer In Charge) conforming to IS:14268 with temporary corrosion protection including supply of all approved fittings and fixtures viz. anchorages, block-outs, wedges, ducts, adhesive tapes, pipes for grouting, HDPE Sheathing,Monobond Encapsulated Anchorages, Barrels, all consumables, etc., including cutting & profiling of H. T. Strands, Ducts, anchorages, tensioning of HT strands, grouting of tendons, all required equipment's, skilled manpower and technicians required to execute the job etc are included in the rates as directed by Engineer In charge.This rate is based on drawing provided without Pour Strip. In case of addition of Pour Strip as per site requirement, rate shall be revised subsequently.
ELECTRICAL WORK
RMU BREAKER WITH (2 INCOMER LOAD BREAK SWITCH + 2 SF6 BREAKER OUTGOINGS) AS PER PUNE MSEDCL/ GOVERNMENT APPROVED 22 KV HT SWITCHGEAR Supply, Receiving, Unloading, Shifting, Storing, Installation Testing & Commissioning of 22kV 630Amps 21KA/1 sec. Ring Main Unit Compact switchgear consisting of 2 NOS. INCOMING LOAD BREAK SWITCH & 2 NOS. SF6 OUTGOING BREAKER in insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. RMU Shall be provided as per Local MSEDCL/Govt standard.
Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil. Capacitive voltage indication fixed type system with LED SF6 Gas pressure indicator. Padlocking facility. Fault passage indicator for incoming Load break switch only Protection CT shall be minimum 150/1A ,5VA ,5P10. - 3 nos. All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work. - 1 Set
22 KV HT VCB PANEL 22/33KV H.T. VCB SEVEN BREAKER PANEL BOARD (2 INCOMMING + 3 OUTGOING+1 SPARE + 1Nos. Bus Coupler) Supply, Receiving, Unloading, Shifting, Storing, Installation Testing & Commissioning of 22KV Five Vacuum Circuit Breaker Panel Board as 2 Incomming, 3 Outgoing+1 Spare & 1 Bus coupler and shall be metal clad floor mounting complete as per BOQ, specification and tender drawing as described.
1250A Vacuum circuit breaker of 31.5KA ruputuring capacity at 22KV rated, totally enclosed, air insulated metal clad housing, floor mounting, horizontal isolation, vermin proof, fully interlocked horizontal drawout type having isolation features and control devices complete with the following: Manually and motor operated, spring charged (release closing mechanism) trip free type,triple pole truck/trolley mounted draw out, vacuum circuit breaker, incorporating mechanical as well as electrical ON/OFF indication. Spring charge/discharge mechanical indication"OFF" push buttons for emergency trip (shrouded) test/service position limit switches with 6 NO/6 NC breaker auxilliary contacts in service position, 24 Volts DC shunt trip coil and strip heater to prevent moisture absorption. HT Panel shall have both & rear door interlock. HT panel shall be Internal arc tested for 31.5KA/1 sec with AFLR classification as per IEC standard & manufacturer shall submit test report certificate.
INCOMING PANEL - 2 NO.(Each feeder shall have following) 1250 A Vacuum circuit breaker of 31.1KA for 3 sec ruputuring capacity, totally enclosed,air insulated metal clad housing, floor mounting, horizontal isolation,vermin proof,fully interlocked horizontal drawout type having isolation features and control devices complete with the following: Single Phase double core current transformer 150/75/5 Amp epoxy cast insulated class of insulation E. Core 1-15VA burden class 1.0 for metering. Core 2- 15VA burden class 5P10 for protection. P.T's of 22KV/1.732, 110V/1.732, 100VA with suitable rating H.T. & L.T. fuse conforming to relevant IS Standards and complete as required.
Spring charge indication. Auto trip indication. 1 No. hooter with hooter acceptance and reset push button. 1 no. master trip relay similar to PQ8 (ABB) or equivalent. Trip circuit supervision relay similar to TCS or equivalent. 1250A color coded heat shrinkable HT sleeved TP Copper busbar of 31.5KA for 3 sec fault rating. 1 Set of fuses, ferrules, wiring etc. as required. 1 Set. Three Phase Electronic static type under / over voltage Protection relays with alarm & indication. (Does not trip the VCB at Zero Voltage) (Model - Minilec - D2 VCT1). Or it can be part of main numerical relay. 1Set Surge protection-3 Nos. surge arrestor of suitable rating for surge protection from main supply - 22KV, 10KA discharge current, Class-2. Window Annunciation - 1 Set 8 Window solid state Audio/ Visual Annunciator with Test/ Accept/ Reset Push buttons and Electronic Hooter. (for O/C, E/F, Master trip opt, PT MCB Failure status, Under / Over voltage)
Note: All spare contacts of breaker or any other equipment inside the breaker shall be wired upto the outgoing terminal strip with appropriate ferrules/ coding. The terminal strip rating shall be suitable for connecting two wires of 2.5sqmm subjected to providing minimum size strip suitable for 4/6sqmm. 1 Set of Power Pack 24V DC Supply Power Pack with 7 Ah Maintenance free Battery back up. Power Pack should be with Protections of over voltage/ under voltage / over charging.
1 No. electronic type digital energy analyser having 30 days memory and parameters of KW, KWH, Power factor, frequency etc. Suitable for BMS compatible with all accessories. 1 Set of following indicating lamps. Red, Yellow & Blue for phase indication. Amber for Trip indication. Red `ON' Green `OFF' Spring charge indication. Auto trip indication. 1 No. hooter with hooter acceptance and reset push button. 1 no. master trip relay similar to PQ8 (ABB) or equivalent. Trip circuit supervision relay similar to TCS or equivalent. 1 Set of fuses, ferrules, wiring etc. as required. Auxiliary relay for transformer fault, alarm and trip as per below. 12 Annunciator window for all electrical and transformer fault. (for O/C, E/F, Master trip opt, WTI-(A & T), OTI-(A&T), Bucholz- (A &T), MOG-(A), PRV-(T), Oil Surge-(T)) Note: All spare contacts of breaker or any other equipment inside the breaker shall be wired upto the outgoing terminal strip with appropriate ferrules/ coding. The terminal strip rating shall be suitable for connecting two wires of 2.5sqmm subjected to providing minimum size strip suitable for 4/6sqmm. 1 Set of Power Pack 24V DC Supply Power Pack with 7 Ah Maintenance free Battery back up. Power Pack should be with Protections of over voltage/ under voltage / over charging. H.T. Panel (Panel, VCB, interrupter, relay & Meter must be of same make for better life cycle optimization) describe as above "Make : Siemens/Schneider Infrastructure /ABB. Note :VCB Panel shall be from OEMs only . Licensed System Integrators are not allowed to supply" Earth Bus - 75 x 6 mm Alu. earth bus with proper bonding to the panel Bus Coupler (1 Nos.) One (1) Nos. 1250A, 3-pole, 22 KV VCB Earth Bus - 75 x 6 mm Alu. earth bus with proper bonding to the panel TOTAL OF 33/22 KV HT PANELS C/O TO SUMMARY
H.T. VCB Panel describe as above
Manhole: Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
SUBSTATION WORKS
DIESEL GENERATING SET: 1500KVA, 415V DG SET WITH CANOPY Supply of 1500 KVA DG Set as per specification coupled with engine of , 16 cylinder four stroke, Radiator cooled developing rated output of min. 1735 BHP at 1500 RPM under NTP condition of ISO 3046. The DG set shall be with sound proof enclosure.The engine shall be complete with starting system with 24 volt DC supply having sealed maintenance free batteries of min. 160 AH / as per manufacturer standard, charger, inbuilt regulator, flywheel, coupling with guard, instrument panel. the engine shall be with exhaust mainfold, residential / hospital type silencer as per genset manufacturer standard, electronic governor and safety system such as low lube pressure, high water temperature, over speed, low coolant level alarm etc. AVM pads, special tools operation manual, including first fill of lube oil with accoustic enclosure as per particular specifications. The alternator shall be for 1500KVA at 0.8 power factor 415 volt, designed at 40 C/S, having class H insulation and temp rise limit to class H, self excited, self regulated, self ventilated in brush less design with automatic voltage regulator having voltage regulation +/- 1% at all load between no load to full loadand having min. of 95% efficiency at 100% load at 0.8 PF as per IEC60034-1 . It shall confirm to IS 4722 / BS 5000 / IEC 60034 & as per specification and equipment schedule. DG Set shall be Provided with PCC-3.3 / Eqv. Controller.
ANCILLARY WORK
FUEL PIPING Supply, fixing, testing and commissioning of MS heavy class piping (Class -C) conformting to IS: 1239 with necessary clamps, supports, anti vibration mountings, hangers and fittings such as bends, tees, reducers etc. painted as per specification.
50 NB Class "C" MS ERW pipe AS ABOVE
40 NB Class "C" MS ERW pipe AS ABOVE
25 NB Class "C" MS ERW pipe AS ABOVE
Supply, & fixing of 990 liter (3.0 mm thick) fuel oil service tank with oil lavel indicator, inlet / outlet connection valve, air vent, pedestal for mounting etc.
Fuel Transfer Pump Supply and installation of 0.5HP (Suitable capacity) fuel transfer pump with flame proof motor starter for transfering fuel from barrel to oil service tank.
Supplying and fixing 6 Amps TPN MPCB's duly Sets housed in Flame proof Enclosure (weather proof) etc. as required
Supply, fixing, testing and commissioning of 25mm dia 5mtr long flexible hose for connecting barral to fuel pump
VALVES & STRAINERS Supply, Receiving shifting to site, fixing and testing of following valves, stariners, for 990 Ltr tank fuel Handling system piping complete with companion flanges,nut bolts gaskets supports and painted etc. as per specification
Ball Valves 50 mm Gunmetal Valve
Ball Valves 40 mm Gunmetal Valve
Ball Valves 25 mm Gunmetal Valve
Non return valves 50 mm dia
Non return valves 40 mm dia
Non return valves 25 mm dia
Y- Strainers 50 mm dia
Y- Strainers 40 mm dia
Y- Strainers 25 mm dia
Pot- strainers 50 mm dia
Pot- strainers 40 mm dia
Pot- strainers 25 mm dia
Foot valves 50 mm dia
Foot valves 40 mm dia
Foot valves 25 mm dia
EXHAUST SYSTEM Supply & fixing of exhaust piping with bends (including 90° and 45° bends), flanges packing and hardwares from flexible pipe outlet to outside including canopy at each outlet of following sizes
400 MM MS ERW pipe (5.2 MM THK) Details as above sr.no 282.26
350 MM MS ERW pipe (5.2 MM THK) Details as above sr.no 282.26
250 MM MS ERW pipe (4.85 MM THK) Details as above sr.no 282.26
200 MM MS ERW pipe (4.65 MM THK) Details as above sr.no 282.26
Supplying and fixing of 75 MM thick, mineral wool insulation (of 96 Kg. Per cubic metre density) over the exhaust pipes of following diameter including cladding covered with wire mesh, aluminium sheet of 26 SWG and covering from outside complete, as required.
400 MM MS ERW pipe (5.2 MM THK) Details as above sr.no 282.31
350 MM MS ERW pipe (5.2 MM THK) Details as above sr.no 282.31
250 MM MS ERW pipe (4.85 MM THK) Details as above sr.no 282.31
200 MM MS ERW pipe (4.65 MM THK) Details as above sr.no 282.31
Insulation of Aluminium clading on residential silencers (1No. 1500KVA DG sets)
Supply & Fixing of SS expansion Bellow for exhaust pipes .
400 MM exhaust SS Bellows
350 MM exhaust SS Bellows
250 MM exhaust SS Bellows
200 MM exhaust SS Bellows
MS STRUCTURE WORK Supply, fabrication, transportation, hoisting, erection & painting of common MS stack structure / MS support for 1500KVA DG Sets Exhaust pipes i.e channel angles, plates, flat, beam sheet etc. as per design including anchor bolts / dash fasterners/ boltsnuts/hardwares etc. as required complete with painting with one coat of primer and two coats of synthetic enamel paint as per approved shade for exhaust stack. (RCC Foundation is out of scope. (Structural Fabrication dwgs will get approval from structural consultant). stack Height Approximate 30-35Meter as per CPCB - IV Norms.
Supply & execution of canopy type MS structure made out of 40mm medium class MS pipe (class-B), 25 x 25 x 3mm angle iron form work and 14 SWG GI sheet structure shall be grouted in 1:2:4 CC foundation for hanging 3 Nos. 9 lit. each fire fighting buckets including providing buckets with two coats of anticorrosive paints etc. complete as required.
D.G SET SHALL BE EQUIPED WITH SYNC. CONTROLLER OF DAIF / WOODWARD / EQV. MAKE The engine & alternator of mentioned makes shall be mounted on common base frame as per specification & equipment schedule. Note: DG sets to be run in synchronizing mode when complete capacity being installed at site. D.G Sets foundation shall be in the contractor scope
1600 KVA DRY TYPE UNITIZED SUB-STATION WITH OFF LOAD TAP CHANGER (OUTDOOR TYPE)
Supply, installation, testing & commissioning of package type/unitised 22kV / 415 V Outdoor sub-station ,1600kVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-20 Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation. Note : CSS shall be from OEMs only . Licensed System Integrators are not allowed to supply.
Package substation will have the following equipment :- HT SWITCHGEAR 22kV 630Amps 21KA/1 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of 1 no. fixed manual Vacuum Circuit Breaker Module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No. Vacuum Interrupter, RMU and CSS shall be of same make to ensure life cycle optimization.
Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil. Capacitive voltage indication fixed type system with LED SF6 Gas pressure indicator. Padlocking facility. Fault passage indicator for incoming Load break switch only Protection CT shall be minimum 50/1A ,5VA ,5P10. - 3 nos. All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work.- 1 Set
TRANSFORMER "1600KVA 22kV/0.415kV Dyn11 Copper Wound, Cast Resin Step Down ,Dry Type Transformer with OFF load tap Changer of +5% to -15% @ 2.5% with WTI scanner. Class of Insulation: H, Temperature rise limits 115 deg.C over an ambient of 50 degrees. Losses (Subject to IS tolerances) - No load losses - as per ECBC 2017 norms, Full load losses - as per ECBC 2017 norms, Vector group - Dyn11 and Impedance of as per IS(Subject to IS Tol.) with WTI scanner Transformer" OUTDOOR ENCLOSURE Outdoor type encloser of 1.6 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robust construction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.
1600 KVA Cu wound dry type (-15 to +15 OFFLTC @ 2.5%) 22kv/415V T/F with 22KV RMU as described above
HT CABLES (INCLUDING INCOMING CABLES FROM MSEDCL) : 22 KV Cable
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 22KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 120 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 22 KV grade of following size in the existing RCC/HUME/ METAL pipe as required. Above 120 sq. mm and upto 400 sq. mm
Supply of HT Cable Supplying of 3 core 22 KV, HT XLPE Earthed cable as per IS:7098 (part-II), on IS angle, supports/ existing hume pipe, including clamps, saddles, screws etc, for fixing cables in indoor trenches, cable route marker mentioned the depth & voltage level at every 20Mtr. etc as required. 3 C x 300 Sq.mm, XLPE HT cable (Earthed)
HT Cable Termination supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 22 KV grade as required : 300 sq. mm
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 22 KV grade as required : 300 sq. mm
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required as approved by architect and complete in all respect.
150 mm dia (FOR L.T.CABLE & COMMUNICATION CABLE)
250 mm dia at 1000 mm depth(H.T..CABLE)
300 mm dia at 900 mm depth(L.T.CABLE)
MAIN PANEL
Design, manufacture, supply, Loading/ Un-Loading, installation, testing and commissioning of Main LT Panel Cum Synchronizing Panel fabricated out of 2mm thick for structural members (Load bearing members) and 1.6mm thick for door and covers (Non load bearing members) CRCA sheet in cubicle compartmentalize free standing floor mounted, dust and vermin proof with reinforcement of suitable size angle iron, channel 'T' irons and/ or flats wherever necessary, 16 gauge CRCA sheet steel shall be used for final distribution panels. Cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be (form-3b Construction) treated with all anticorrosive process before painting as per specifications with 2 coats of zinc chromate primer and final approved shade of enamelled paint. 2 Nos. earthing terminals shall be provided for all distribution panels. Panels shall be suitable for 415V, 3-phase, 4-wire, 50Hz supply system and with 15% spare space, lifting hooks shall also be provided in case of large panels.
Approval shall be taken for each panel before fabrication. Galvanized hardwares with zinc passivation shall be used in fabrication of panels. ACB: LSIG (Microprocessor Based) releases with Display & Comm. Port shall be used for incoming feeders such as Transformers and DG Sets & LSI releases for outgoing breakers. MCCB: MCCBs of above 250A Microprocessor Based and upto 250A thermal Magnetic releases.
Breaking capacity mentioned is Ics value. This BOQ to be read in conjunction with technical specifications and Single Line Diagram (attached for reference). If any discrepancy occurs that should be brought to the notice of Client/Consultant before quoting the price otherwise stringent condition will be deemed to have been considered. All MCCBs shall be provided with rotary operating handle and ON/OFF lamps backed by 2Amp control MCB. All meters shall be digital type (unless otherwise specified) Multi-function meter with Rs-485 port to be provided as required to cover all the parameters as mentioned. All current/voltage transformer shall be cast resin type. All indicating lamps shall be LED type. Current density for bus bar shall not be more than 0.8A/Sqmm. Rating of Bus bar is after considering all derating factors. (Bus bar sizing calculation to be submitted for approval.) All internal control wiring shall be heat resistant type. All incoming breakers in Main LT panel shall be electrically interlocked. Bus bar chamber shall be provided at top only. Incoming and outgoing cable entry shall be from top/bottom as required. All feeders shall be provided with door interlocked with door defeat, pad lock facility. Live parts shall not be accessible after opening the door, Transparent acrylic sheet to be provided to cover the same. Spare contacts of ACBs/ MCCBs/ Relay/ Contactor shall be wired upto terminal block. 20% spare control terminal to be provided. All MCCBs shall be provided with variable O/L & S/C releases. Incoming MCCB shall be provided with E/F releases also All incoming/outgoing cables shall be terminated on links/terminals.
Protection: Undervoltage Relay (Inside Breaker). Overvoltage Relay (Inside Breaker). Under Frequency (Inside Breaker). Over Frequency (Inside Breaker). Maximum Demand (Inside Breaker). Leading & Lagging Power Factor (Inside Breaker). Earth Fault Relay REF Restricted earth relay Relay (6 Nos). Phase Sequence Relay (3Nos.) Reverse Power Relay (3Nos.) 3 Sets of 8 window Annunciator with Hooter,Auxillary Relays & all required Accessories for Relay Fault. 3Sets of metering C.T. of suitable ratio for 1Nos. APFC Relay in Capacitor control Panel at Transformer incomer. 3 Set of Surge Suppressor type B+C wiith 160A 4P FUSE backup protection.
MAIN BUS BAR Three sets of 5000 A, TPN, 36kA, TPN AL. Bus Bar with PVC Sleeve in sealed Bus Chamber. Bus Coupler (2 Nos.) Two (2) Nos. 2500A, 4-pole, EDO type ACB (microprocessor based with all releases) (50kA) with ON/OFF indication. INTERLOCKING Electrical interlocking between 3Nos. Transformer incoming ACB's, 3 Nos. D.G. supply incoming ACB's & 2 No. Bus coupler 2500A ACB's so that any of the incoming ACB "ON" one bus & Bus coupler ACB's or only any of the incoming ACB on both with Bus coupler "OFF" can be closed at a time as per interlocking sequrence required. When main supply trips then DG should start automatically & Vice versa to restore power supply, with auto change over at the incomers. System should include Micro PLC etc as required as approved by architect and complete in all respect.
OUTGOINGS : Three (3) Nos. 2500A, TP+N MDO ACB.(50K) Three (3) Nos. 800A, TP+N MDO ACB.(36K) Six (6) Nos.3-phase Digital Energy Meters with RS -485 Port (Dual Source) with necessary CTs. AUTO START / AUTO STOP & AUTO / MANUAL LOAD SHARING, AUTO LOAD MANAGEMENT THROUGH PLC (SHALL BE CONSIDERED WOODWARD / DIEF EQV. RELAY CONTROLLER FOR AUTO SYNCHRONISATION DUE TO UN-AVAILABILITY OF PCC-3.3 CONTROLLER POWER COMMAND)
BATTERY CHARGER:- (For DG Sets) 3 Sets 24V 30A DC Battery charger having proterction of over Voltage / Under voltage / Over charging. Battery charger shall be comptele with DC ammeter , DC Voltmeter & LED indicating lamps as required. * Upto 500KVA DG Sets Capacity 20A & Above 500KVA DG Sets 30A DC Charger shall be provided. - Suitable size of Exhaust fans with Air filter as per requirment. - Mimic Panel shall be Provided sufficient size (370mmX270mm) as per suggested in Previuos projects, Indicative LED lamp type. - Panel space heaters with control MCB & Thermostat, covered LED lamp controlled by door switch for each panel.
1 No. 75 x 6 mm. Aluminium earth bus across the width of panel Any additional component/ device (Including UPS, SMPS, Power supply, power pack) required for proper operation of control/ synchronization/ interlocking scheme shall be considered by Panel manufacturer without any additional cost. FIRE SUPPRESSION SYSTEM IN ABOVE MAIN LT PANEL Supply, Installation, testing & commissioning of fire suppression sytem in Above Main LT Panel with Novec gas (FK 5 112 / Eqv) including heat detection polymide tube alongwith master control unit & all fixing accessories to complete the job. (Make: Honeywell / Ceasefire / minimax)
Main LT Panel described above.
MAIN BUILDING DISTRIBUTION PANEL (MBDP) Design, manufacture, supply, Loading/ Un-Loading, installation, testing and commissioning of Main LT Panel Cum Synchronizing Panel fabricated out of 2mm thick for structural members (Load bearing members) and 1.6mm thick for door and covers (Non load bearing members) CRCA sheet in cubicle compartmentalize free standing floor mounted, dust and vermin proof with reinforcement of suitable size angle iron, channel 'T' irons and/ or flats wherever necessary, 16 gauge CRCA sheet steel shall be used for final distribution panels. Cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be (form-3b Construction) treated with all anticorrosive process before painting as per specifications with 2 coats of zinc chromate primer and final approved shade of enamelled paint. 2 Nos. earthing terminals shall be provided for all distribution panels. Panels shall be suitable for 415V, 3-phase, 4-wire, 50Hz supply system and with 15% spare space, lifting hooks shall also be provided in case of large panels.
Approval shall be taken for each panel before fabrication. Galvanized hardwares with zinc passivation shall be used in fabrication of panels. ACB: LSIG (Microprocessor Based) releases with Display & Comm. Port shall be used for incoming feeders such as Transformers and DG Sets & LSI releases for outgoing breakers. MCCB: MCCBs of above 250A Microprocessor Based and upto 250A thermal Magnetic releases.
Breaking capacity mentioned is Ics value. This BOQ to be read in conjunction with technical specifications and Single Line Diagram (attached for reference). If any discrepancy occurs that should be brought to the notice of Client/Consultant before quoting the price otherwise stringent condition will be deemed to have been considered. All MCCBs shall be provided with rotary operating handle and ON/OFF lamps backed by 2Amp control MCB. All meters shall be digital type (unless otherwise specified) Multi-function meter (EM6436 or equivelent) and Meter can be capable to show olts, Amps, F & PF Simultaneously, W/VA.to be provided as required to cover all the parameters as mentioned. All current/voltage transformer shall be cast resin type. All indicating lamps shall be LED type. Current density for bus bar shall not be more than 0.8A/Sqmm. Rating of Bus bar is after considering all derating factors. (Bus bar sizing calculation to be submitted for approval.)
All internal control wiring shall be heat resistant type. All incoming breakers in Main LT panel shall be electrically interlocked. Bus bar chamber shall be provided at top only. Incoming and outgoing cable entry shall be from top/bottom as required. All feeders shall be provided with door interlocked with door defeat, pad lock facility. Live parts shall not be accessible after opening the door, Transparent acrylic sheet to be provided to cover the same. Spare contacts of ACBs/ MCCBs/ Relay/ Contactor shall be wired upto terminal block. 20% spare control terminal to be provided. All MCCBs shall be provided with variable O/L & S/C releases. Incoming MCCB shall be provided with E/F releases also All incoming/outgoing cables shall be terminated on links/terminals.
Protection: Undervoltage Relay (Inside Breaker). Overvoltage Relay (Inside Breaker). Under Frequency (Inside Breaker). Over Frequency (Inside Breaker). Maximum Demand (Inside Breaker). Leading & Lagging Power Factor (Inside Breaker). Earth Fault Relay 1No. RPR (Reverse Power Relay) at Solar incomer
MAIN BUS BAR Two sets of 2500 A, TPN, 50kA, TPN AL. Bus Bar with PVC Sleeve in sealed Bus Chamber. Bus Coupler (1 Nos.) One (1) Nos. 2500A, 4-pole, EDO type ACB (microprocessor based with all releases) (50kA) with ON/OFF indication. INTERLOCKING Electrical interlocking between 2Nos. Transformer incoming ACB's, 1No. Solar supply incoming ACB's & 1 No. Bus coupler 2500A ACB's & so that any of the incoming ACB "ON" one bus & Bus coupler ACB's or only any of the incoming ACB on both with Bus coupler "OFF" can be closed at a time as per interlocking sequrence required. When main supply trips then DG should start automatically & Vice versa to restore power supply, with auto change over at the incomers. System should include Micro PLC etc as required as approved by architect and complete in all respect.
OUTGOINGS : Tow (2) Nos. 1000A, TP+N MDO ACB.(50K) (HVAC Panel Feeder) Two (2) Nos. 630A, TP+N MCCB.(36K) (Cap. Panel) Two (2) Nos. 250A, TP+N MCCB.(36K) (Future Floor- 1&2 ) Three (3) Nos. 200A, TP+N MCCB.(36K) (G.F,S.F,T.F L,SP& CSU/AHU Panel) One (1) Nos. 200A, TP+N MCCB.(36K) (Future Floor) Two (2) Nos. 200A, TP+N MCCB.(36K) (Lift Panel ( W+S)) Two (2) Nos. 200A, TP+N MCCB.(36K) (UPS Panel-1 & Panel-2) One (1) Nos. 200A, TP+N MCCB.(36K) (Fire Fighting Panel) One (1) Nos. 160A, TP+N MCCB.(36K) (Ventilation Panel G.F) One (1) Nos. 160A, TP+N MCCB.(36K) (EV Vehical Charging Panel) Provision One (1) Nos. 125A, TP+N MCCB.(36K) (Plumbing Panel)
One (1) Nos. 100A, TP+N MCCB.(36K) (Ventilation For Lift Pressurization) Two (2) Nos. 100A, TP+N MCCB.(36K) (External Feeder-1 & 2) One (1) Nos. 100A, TP+N MCCB.(36K) (For Dedicated Server panel) One (1) Nos. 100A, TP+N MCCB.(36K) (For STP Panel Incomer) One (1) Nos. 1000A, TP+N MDO ACB.(50K) (Spare) One (1) Nos. 630A, TP+N MCCB.(36K) (Spare) One (1) Nos. 400A, TP+N MCCB.(36K) (Spare) One (1) Nos. 250A, TP+N MCCB.(36K) (Spare) One (1) Nos. 125A, TP+N MCCB.(36K) (Spare) One (1) Nos. 100A, TP+N MCCB.(36K) (Spare) 2 Nos. B+C Type (SDP) with 160A 4P Fuse 28 Nos.3-phase Digital Energy Meters with RS -485 Port (EM6436 or equivelent) with necessary CTs. Meter can be capable to show olts, Amps, F & PF Simultaneously, W/VA. FIRE SUPPRESSION SYSTEM IN ABOVE MAIN BUILDING DISTRIBUTION PANEL (MBDP) Supply, Installation, testing & commissioning of fire suppression sytem in Above MAIN BUILDING DISTRIBUTION PANEL (MBDP) with Novec gas (FK 5 112 / Eqv) including heat detection polymide tube alongwith master control unit & all fixing accessories to complete the job. (Make: Honeywell / Ceasefire / minimax)
Main Building Distribution Panel described above.
2 NOS. CAPACITOR PANEL (CCP) 250 KVAR :- Note: Provision for APFCR Panel to be made in such a way that if any transformer will go in shutdown for maintenance than its relevant capacitor panel will do compensation of power factor for other transformer which isnow taking load of shutdown transformer.
OUTGOING : Capacitor Banks shall be Heavy Duty type equal to MPP- HD and 7% detuned reactor shall be copper wound only design at 525V. 2 Set of 50KVAR Capacitor bank with 7% Harmonic Block Reactor, 125A TP contactor and 125 A TP MCCB (25kA) Capacitor rating to be designed for required output KVAR at 415V. 4 Sets of 25 KVAR Capacitor bank with 7% Harmonic Block Reactor, 63A TP contactor and 63 A TP MCCB (25kA) Capacitor rating to be designed for required output KVAR at 415V. 2 Sets of 15 KVAR Capacitor bank with 7% Harmonic Block Reactor, 40A TP contactor and 40 A TP MCCB (25kA) Capacitor rating to be designed for required output KVAR at 415V. 1 Set of 10 KVAR Capacitor bank with 7% Harmonic Block Reactor, 32A TP contactor and 32 A TP MCCB (25kA) Capacitor rating to be designed for required output KVAR at 415V. 2 Set of 5 KVAR Capacitor bank with 7% Harmonic Block Reactor, 16A TP contactor and 16 A TP MCCB (25kA) Capacitor rating to be designed for required output KVAR at 415V. 1 Nos. B+C Type (SDP) with 125A 4P Fuse Capacitor shall be rated @ 525 Volt for required capacitor value at 415V after 7% derating.
CAPACITOR PANEL described above.
GROUND FLOOR L, SP & AHU/CSU PANEL INCOMING : 1 No. 200A, 4P MCCB (25KA) with inbuilt Thermal Magnatic based release for Over load, Short circuit & Earth Fault protection. BUS BAR : One set of 250A TPN Alu. Bus Bar 25 kA with PVC Sleeve in sealed bus chamber. METERING AND INDICATIONS 1 No. digital Multi Function Meter (A,V, KWH) and CT's & control MCBs. (EM 6436/Eqv and Meter can be capable to show olts, Amps, F & PF Simultaneously, W/VA etc 1 set of R/Y/B phase indication Lamp & MCB. 1 Set of ON/OFF/TRIP Indicating lamps .
OUTGOING : 8 nos. 63A FP MCB (10KA) C-Curve 6 nos. 40A FP MCB (10KA) C-Curve 4 nos. 32A FP MCB (10KA) C-Curve 8 nos. 20A FP MCB (10KA) C-Curve 4 nos. 16A FP MCB (10KA) C-Curve 1 Nos. B+C Type (SDP) with 125A 4P Fuse
G.F Light small power, CSU/AHU Panel described above.
SECOND FLOOR LIGHT, SMALL POWER & AHU/CSU PANEL INCOMING : 1 No. 200A, 4P MCCB (25KA) with inbuilt Thermal Magnatic based release for Over load, Short circuit & Earth Fault protection. BUS BAR : One set of 250A TPN Alu. Bus Bar 35 kA with PVC Sleeve in sealed bus chamber. METERING AND INDICATIONS 1 No. digital Multi Function Meter ( A,V, KWH) and CT's & control MCBs. (EM 6436/Eqv) and Meter can be capable to show olts, Amps, F & PF Simultaneously, W/VA etc 1 set of R/Y/B phase indication Lamp & MCB. 1 Set of ON/OFF/TRIP Indicating lamps .
OUTGOING : 7 nos. 63A FP MCB (10KA) C-Curve 5 nos. 40A FP MCB (10KA) C-Curve 1 nos. 32A FP MCB (10KA) C-Curve 7 nos. 25A FP MCB (10KA) C-Curve 6 nos. 20A FP MCB (10KA) C-Curve 2 nos. 16A FP MCB (10KA) C-Curve 1 Nos. B+C Type (SDP) with 125A 4P Fuse
S.F Light small power, CSU/AHU Panel described above.
THIRD FLOOR LIGHT, SMALL POWER & AHU/CSU PANEL INCOMING : 1 No. 200A, 4P MCCB (25KA) with inbuilt Thermal Magnatic based release for Over load, Short circuit & Earth Fault protection. BUS BAR : One set of 250A TPN Alu. Bus Bar 35 kA with PVC Sleeve in sealed bus chamber. METERING AND INDICATIONS 1 No. digital Multi Function Meter ( A,V, KWH) and CT's & control MCBs. (EM 6436/Eqv) and Meter can be capable to show olts, Amps, F & PF Simultaneously, W/VA etc 1 set of R/Y/B phase indication Lamp & MCB. 1 Set of ON/OFF/TRIP Indicating lamps .
OUTGOING : 9 nos. 63A FP MCB (10KA) C-Curve 5 nos. 40A FP MCB (10KA) C-Curve 3 nos. 32A FP MCB (10KA) C-Curve 3 nos. 25A FP MCB (10KA) C-Curve 12 nos. 20A FP MCB (10KA) C-Curve
T.F Light small power, CSU/AHU Panel described above.
VENTILATION PANEL (GROUND FLOOR) INCOMING : 1 No. 160A, 4P MCCB (25KA) with inbuilt Thermal Magnatic based release for Over load, Short circuit & Earth Fault protection. BUS BAR : One set of 200A TPN Alu. Bus Bar 35 kA with PVC Sleeve in sealed bus chamber. METERING AND INDICATIONS 1 No. digital Multi Function Meter ( A,V, KWH) and CT's & control MCBs. (EM 6436/Eqv) and Meter can be capable to show olts, Amps, F & PF Simultaneously, W/VA etc 1 set of R/Y/B phase indication Lamp & MCB. 1 Set of ON/OFF/TRIP Indicating lamps .
OUTGOING : 2 nos. 63A TP+N MCCB (25KA) 1 nos. 63A FP MCB (10KA) D-Curve 2 nos. 40A FP MCB (10KA) D-Curve 5 nos. 25A FP MCB (10KA) D-Curve 1 Nos. B+C Type (SDP) with 125A 4P Fuse
Ventilation Panel (Ground Floor) described above.
SUB VENTITION PANEL (SECOND FLOOR) INCOMING : 1 No. 63A, 4P MCCB (25KA) with inbuilt Thermal Magnatic based release for Over load, Short circuit & Earth Fault protection. BUS BAR : One set of 100A TPN Alu. Bus Bar 25 kA with PVC Sleeve in sealed bus chamber. METERING AND INDICATIONS 1 No. digital Multi Function Meter ( A,V, KWH) and CT's & control MCBs. (EM 6436/Eqv) and Meter can be capable to show olts, Amps, F & PF Simultaneously, W/VA etc 1 set of R/Y/B phase indication Lamp & MCB. 1 Set of ON/OFF/TRIP Indicating lamps .
OUTGOING : 3 nos. 32A FP MCB (10KA) D-Curve 5 nos. 20A FP MCB (10KA) D-Curve
Sub-Ventilation Panel (Second Floor) described above.
SUB VENTITION PANEL (THIRD FLOOR) INCOMING : 1 No. 63A, 4P MCCB (25KA) with inbuilt Thermal Magnatic based release for Over load, Short circuit & Earth Fault protection. BUS BAR : One set 100A TPN Alu. Bus Bar 35 kA with PVC Sleeve in sealed bus chamber. METERING AND INDICATIONS 1 No. digital Multi Function Meter ( A,V, KWH) and CT's & control MCBs. (EM 6436/Eqv). 1 set of R/Y/B phase indication Lamp & MCB. 1 Set of ON/OFF/TRIP Indicating lamps . OUTGOING : 2 nos. 32A FP MCB (10KA) D-Curve 5 nos. 25A FP MCB (10KA) D-Curve 1 nos. 20A FP MCB (10KA) D-Curve
Sub-Ventilation Panel (Third Floor) described above.
VENTILATION PANEL (LIFT PRESS.) INCOMING : 1 No. 100A, 4P MCCB (25KA) with inbuilt Thermal Magnatic based release for Over load, Short circuit & Earth Fault protection. BUS BAR : One set of 150A TPN Alu. Bus Bar 35 kA with PVC Sleeve in sealed bus chamber. METERING AND INDICATIONS 1 No. digital Multi Function Meter ( A,V, KWH) and CT's & control MCBs. (EM 6436/Eqv) and Meter can be capable to show olts, Amps, F & PF Simultaneously, W/VA etc 1 set of R/Y/B phase indication Lamp & MCB. 1 Set of ON/OFF/TRIP Indicating lamps . OUTGOING : 11 nos. 25A FP MCB (10KA) D-Curve 1 Nos. B+C Type (SDP) with 125A 4P Fuse
Ventilation Panel (Lift Press.) described above.
MAIN UPS PANEL INCOMING : 2 No. 200A, TP+2N MCCB (25KA) with inbuilt Thermal Magnatic based release for Over load, Short circuit & Earth Fault protection. BUS BAR : One set of 400A TP+2N Cu. Bus Bar 35 kA with PVC Sleeve in sealed bus chamber. METERING AND INDICATIONS 2Nos. digital Multi Function Meter ( A,V, KWH) and CT's & control MCBs. (EM 6436/Eqv) and Meter can be capable to show olts, Amps, F & PF Simultaneously, W/VA etc 2 sets of R/Y/B phase indication Lamp & MCB. 2 Sets of ON/OFF/TRIP Indicating lamps .
OUTGOING : 5 nos. 100A TPN MCCB (25KA) (G.F,S.F,T.F UPS Main DB) 1 nos. 100A TPN MCCB (25KA) (Spare)) 1 no. 63A TPN MCCB (25KA) 1 nos. 63A FP MCB (10KA) C-Curve (Spare) 1 nos. 32A FP MCB (10KA) C-Curve (Spare) 1 Nos. B+C Type (SDP) with 125A 4P Fuse MCCB IN INSULATED ENCLOSURE FOR UPS 2 Nos. 200A 4P MCCB 2 Nos. 200A TP +2N MCCB 1 Nos. 63A 4P MCCB 1 Nos. 63A TP+2N MCCB
Main UPS Panel described above.
G.F MAIN UPS DB INCOMING : 1 No. 100A, 4P MCCB (25KA) with inbuilt Thermal Magnatic based release for Over load, Short circuit & Earth Fault protection. BUS BAR : One set of 150A TPN Alu. Bus Bar 35 kA with PVC Sleeve in sealed bus chamber. METERING AND INDICATIONS 1 No. digital Multi Function Meter ( A,V, KWH) and CT's & control MCBs. (EM 6436/Eqv) and Meter can be capable to show olts, Amps, F & PF Simultaneously, W/VA etc 1 set of R/Y/B phase indication Lamp & MCB. 1 Set of ON/OFF/TRIP Indicating lamps .
OUTGOING : 4 nos. 40A FP MCB (10KA) C-Curve UPS DB (Small Power) 2 nos. 40A FP MCB (10KA) C-Curve Emergency Light DB-1,2 1 nos. 40A DP MCB (10KA) C-Curve BMS 1 nos. 25A DP MCB (10KA) C-Curve (Fire Alarm) 1 nos. 100A FP MCCB (16KA) (Spare)) 2 nos. 63A FP MCCB (16KA) 2 nos. 40A FP MCB (10KA) C-Curve (Spare)
Main UPS DB GF described above.
S.F MAIN UPS DB INCOMING : 1 No. 100A, 4P MCCB (25KA) with inbuilt Thermal Magnatic based release for Over load, Short circuit & Earth Fault protection. BUS BAR : One set of 150A TPN Alu. Bus Bar 35 kA with PVC Sleeve in sealed bus chamber. METERING AND INDICATIONS 1 No. digital Multi Function Meter ( A,V, KWH) and CT's & control MCBs. (EM 6436/Eqv) and Meter can be capable to show olts, Amps, F & PF Simultaneously, W/VA etc 1 set of R/Y/B phase indication Lamp & MCB. 1 Set of ON/OFF/TRIP Indicating lamps .
OUTGOING : 4 nos. 40A FP MCB (10KA) C-Curve For UPSDB-1/2/3/4 2 nos. 40A FP MCB (10KA) C-Curve Emergency Light DB-1,2 2 nos. 40A FP MCB (10KA) C-Curve (Spare)
Main UPS DS S.F described above.
T.F MAIN UPS DB INCOMING : 1 No. 100A, 4P MCCB (25KA) with inbuilt Thermal Magnatic based release for Over load, Short circuit & Earth Fault protection. BUS BAR : One set of 150A TPN Alu. Bus Bar 35 kA with PVC Sleeve in sealed bus chamber. METERING AND INDICATIONS 1 No. digital Multi Function Meter ( A,V, KWH) and CT's & control MCBs. (EM 6436/Eqv) and Meter can be capable to show olts, Amps, F & PF Simultaneously, W/VA etc 1 set of R/Y/B phase indication Lamp & MCB. 1 Set of ON/OFF/TRIP Indicating lamps .
OUTGOING : 4 nos. 40A FP MCB (10KA) C-Curve For UPSDB-1/2/3/4 2 nos. 40A FP MCB (10KA) C-Curve Emergency Light DB-1,2 2 nos. 40A FP MCB (10KA) C-Curve (Spare)
Main UPS DS T.F described above.
MAIN ELEVATOR PANEL-1 INCOMING : 2 No. 200A, TP+N MCCB (25KA) with inbuilt Thermal Magnatic based release for Over load, Short circuit & Earth Fault protection as approved by architect and complete in all respect. 2 No. 200A, 4P Power Contactor Electrical Interlocking between Two Incomers BUS BAR : One set of 250A TPN Alu. Bus Bar 25 kA with PVC Sleeve in sealed bus chamber. METERING AND INDICATION : 2 Nos. digital Multi Function Meter ( A,V, KWH) and CT's & control MCB's (Eqv. To EM6436) and Meter can be capable to show olts, Amps, F & PF Simultaneously, W/VA etc Two set of R/Y/B phase indication Lamp with control MCBs. 2 Sets of ON/OFF/TRIP Indicating lamps .
OUTGOING : 2 Nos. 100A TPN MCCB (25KA) (Sub Lift Panel) 2 Nos. 63A TPN MCCB (25KA) (Lift-1/2) 1 Nos. 100A TPN MCCB (25KA) (Spare) 1 Nos. 63A 4P RCBO (100mA) 3 Nos. 40A FP MCB (10KA) C-Curve 1 Nos. B+C Type (SDP) with 125A 4P Fuse
MAIN ELEVATOR PANEL described above.
ELEVATOR PANEL-2 & PANEL-3 INCOMING : 1 No. 100A, TP+N MCCB (25KA) with inbuilt Thermal Magnatic based release for Over load, Short circuit & Earth Fault protection as approved by architect and complete in all respect. BUS BAR : One set of 150A TPN Alu. Bus Bar 25 kA with PVC Sleeve in sealed bus chamber. METERING AND INDICATION : 1 No. digital Multi Function Meter (A,V, KWH) and CT's & control MCB's (Eqv. To EM6436) and Meter can be capable to show olts, Amps, F & PF Simultaneously, W/VA etc One set of R/Y/B phase indication Lamp with control MCBs. 1 Sets of ON/OFF/TRIP Indicating lamps .
OUTGOING : 2 Nos. 63A TPN MCCB (25KA) (Lift-1/2) 1 No. 63A 4P RCBO (100mA) (10KA) 3 Nos. 40A FP MCB (10KA) C-Curve
ELEVATOR PANEL-2 & PANEL-3 described above.
PLUMBING PANEL INCOMING : 1 No. 125A, 4P MCCB (25KA) with inbuilt Thermal Magnatic based release for Over load, Short circuit & Earth Fault protection as approved by architect and complete in all respect. BUS BAR : One set of 200 A TPN Alu. Bus Bar, 36kA with PVC Sleeve in sealed Powder Coated Bus Chamberas approved by architect and complete in all respect. METERING AND INDICATION : 1 No. digital Multi Function Meter ( A,V, KWH) and CT's & control MCB's (Eqv. To EM6436) and Meter can be capable to show olts, Amps, F & PF Simultaneously, W/VA etc One set of R/Y/B phase indication Lamp with control MCBs. 1 Sets of ON/OFF/TRIP Indicating lamps .
OUTGOING : 2 Nos. 50A TP MPCB (50KA) with Star delta Starter (1W+1S) & O/L Relay according to type -2 co-ordination, current sensing single phasing preventor, Ammeter with 1 C.T., Start/Stop Push Button, ON/OFF/TRIP indication Lamps, control MCB 6A and associate wiring as required. for 30HP/22.4 K.W 2 Nos. 14A TP MPCB (50KA) with DOL Starter (1W+1S) & O/L Relay according to type -2 co-ordination, current sensing single phasing preventor, Ammeter with 1 C.T., Start/Stop Push Button, ON/OFF/TRIP indication Lamps, control MCB 6A and associate wiring as required. for 5HP/3.7K.W 4 Nos. 10A TP MPCB (50KA) with DOL Starter (1W+1S) & O/L Relay according to type -2 co-ordination, current sensing single phasing preventor, Ammeter with 1 C.T., Start/Stop Push Button, ON/OFF/TRIP indication Lamps, control MCB 6A and associate wiring as required. for 3HP/2.2 K.W
2 Nos.7A TP MPCB (50KA) with DOL Starter (1W+1S) & O/L Relay according to type -2 co-ordination, current sensing single phasing preventor, Ammeter with 1 C.T., Start/Stop Push Button, ON/OFF/TRIP indication Lamps, control MCB 6A and associate wiring as required. for 1HP/ 0.7K.W 2 Nos. 6A TP MPCB (50KA) with DOL Starter (2W+2S) & O/L Relay according to type -2 co-ordination, current sensing single phasing preventor, Ammeter with 1 C.T., Start/Stop Push Button, ON/OFF/TRIP indication Lamps, control MCB 6A and associate wiring as required. for 2HP/1.5 K.W 1 Nos. 50A TP MPCB (50KA) 1 Nos. 14A TP MPCB (50KA) 1 Nos. 10A TP MPCB (50KA) 1 Nos. B+C Type (SDP) with 125A 4P Fuse
PLUMBING PANEL described above.
FIRE FIGHTING PANEL INCOMING : 1 No. 200A, 4P MCCB (25KA) with inbuilt Thermal Magnatic based release for Over load, Short circuit & Earth Fault protection as approved by architect and complete in all respect. BUS BAR : One set of 250 A TPN Alu. Bus Bar, 25kA with PVC Sleeve in sealed Powder Coated Bus Chamberas approved by architect and complete in all respect. METERING AND INDICATION : 1 No. digital Multi Function Meter ( A,V, KWH) and CT's & control MCB's (Eqv. To EM6436) and Meter can be capable to show olts, Amps, F & PF Simultaneously, W/VA etc One set of R/Y/B phase indication Lamp with control MCBs. 1 Sets of ON/OFF/TRIP Indicating lamps .
OUTGOING : 2 Nos. 150A TP MCCB (25KA) with Soft Stator & O/L Relay according to type -2 co-ordination, current sensing single phasing preventor, Ammeter with 1 C.T., Start/Stop Push Button, ON/OFF/TRIP indication Lamps, control MCB 6A and associate wiring as required for Hydrant pump 75HP/56. KW 2 Nos. 16A TP MPCB (10KA) with DOL Starter & O/L Relay according to type -2 co-ordination, current sensing single phasing preventor, Ammeter with 1 C.T., Start/Stop Push Button, ON/OFF/TRIP indication Lamps, control MCB 6A and associate wiring as required for Fire Terrace pump 7.50HP/(5.6KW) 1 Nos. 160A TP MCCB (25KA) 1 Nos. 14A TP MPCB (50KA)
FIRE FIGHTING PANEL described above.
MCB BEFORE CONTACTOR / WITHOUT TIMER 4Nos 40A 4P MCB (10kA) for LPDB For HT/Meter, Guard Room-1 ,2 &3,4 2Nos 40A 4P MCB (10kA) for Sliding Gate-1 & 2 3 Nos 40A 4P MCB (10kA) for Spare 1 Nos 25A 4P MCB (10kA) for Spare 2 Nos 20A 4P MCB (10kA) for Spare 2 Nos 6A 4P MCB (10kA) for Spare B+C Type (SDP) with 63A 4P Fuse Internal wiring
Feeder Pillar Panel described as above
POINT WIRING & ACCESSORIES
WIRING IN MS CONDUIT
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit,and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. FOR LIGHTING CIRCUIT/ SUB MAIN WIRING
2x1.5 sq mm + 1x1.5 sq mm earth wire
2x2.5 sq mm + 1x2.5 sq mm earth wire
2x6 sq mm + 1x6 sq mm earth wire
2x10 sq mm + 1x10 sq mm earth wire
4x6 Sq. mm + 2x6 Sq. mm Cu earth wire.
4 X 10sq.mm + 2 X 6 sq.mm earth wire
4 X 16sq.mm + 2 X 6 sq.mm earth wire.
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
20mm dia
25mm dia
32mm dia
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing of 3 nos.20A 3PIN SP MOULDED SOCKET FOR WATER COOLER modular socket outlet and 20A amps modular switch, connection etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supply and fixing following size/modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1 or 2 module (75mmX75mm)
3 Module (100mmX75mm)
6 Module (200mmX75mm)
8 Module (125mmX125mm)
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
RACE WAYS AND JUNCTION BOXES AND COVERS Supply & fixing of following size (GI RACEWAY- Fabricated from 1.5 mm thick GI Sheet) race ways for electrical & LV wiring including Fixing Bracket, Coupler, neoprene gasket in joints, bends, sockets cutting the floor & jaming the race way/ hanging in ceiling, supporting arrangement as approved by consultant/ architect with all necessary hard ware (including civil work) as per site requirement. The thickness of raceway & cover shall be as per technical specification.
100 mm wide x 38 mm deep. (1 Compartment)
150 mm wide x 38 mm deep. (2 Compartment)
150 mm wide x 38 mm deep. (1 Compartment)
225 mm wide x 38 mm deep. (3 Compartments)
300 mm wide x 38 mm deep. (3 Compartments)
Supply & fixing of following size of Raceway Junction Box made out of 2.0 mm thick GI Sheet & top cover of 3mm thick GI Sheet for electrical & LV wiring including, cutting the floor & jaming the junction box/ hanging in ceiling, supporting arrangement as approved by consultant/ architect with all necessary hard ware (including civil work). (Junction box to be provided as per drawing/ as per site requirement & as per specification). Height of the junction box should be adjustable from 65-90mm. Junction box should be supplied with the metal cover for protecting the junction box during constructions at site.
150 mm wide x 38 mm deep. (1 Compartment)
225 mm wide x 38 mm deep. (3 Compartments)
300 mm wide x 38 mm deep. (3 Compartments)
MV DISTRIBUTION BOARDS
MCB DISTRIBUTION BOARDS Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
6 way, Double door
8 way, Double door
12 way, Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
6 way (4 + 18), Double door
8 way (4 + 24), Double door
12 way (4 + 36), Double door
Supplying and finishing 5 amps to 32 amps rating, 240 volts 'C' series, miniature circuit breaker suitable for inductive and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, 'C' series, four pole, 415 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, 'C' series, Double pole, 240 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.
MV CABLES, FIRE SURVIVAL CABLE & CABLE TRAY
With Sand & Protective Covering
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and up to 95 sq.mm (clamped with 25x3 mm MS Flat clamp)
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
4 X 35 sq. mm (32mm)
3½ X 50 sq. mm (35 mm)
3½ X 70 sq. mm (38mm)
3½ X 95 sq. mm (45 mm)
3½ X 120 sq. mm (45 mm)
3½ X 150 sq. mm (50 mm)
3½ X 185 sq. mm (57mm)
3½ X 240 sq. mm (62mm)
3½ X 300 sq. mm (70 mm)
3½ X 400 sq. mm (90 mm)
4 X 10 sq. mm (25 mm)
4 X 16 sq. mm (28mm)
4 X 25 sq. mm (28mm)
4C X 6 Sq.mm
4C X 4 Sq.mm
4C X 2.5 Sq.mm
3C x 16 Sqmm
3C x 10 Sqmm
3C x 6 Sqmm
3C x 4 Sqmm
3C x 2.5 Sqmm
Supply, loading, transportation unloading at site, storages at site, shifting from storage place to site of following sizes of XLPE insulated PVC sheathed, FRLS, Aluminium/Copper conductor armoured power cable of 1.1 KV grade conforming to IS amended upto date and as per specifications. Aluminium conductor
3.5C x 400 Sq.mm
3.5C x 300 Sq.mm
3.5C x 240 Sq.mm
3.5C x 185 Sq.mm
3.5 C x 150 Sq.mm
3.5 C x 120 Sq.mm
3.5 C x 95 Sq.mm
3.5 C x 70 Sq.mm
3.5 C x 50 Sq.mm
4 C x 35 Sq.mm
4C X 25 Sq.mm
4C X 16 Sq.mm
Copper conductor:-
4C X 16 Sq.mm
4C X 10 Sq.mm
4C X 6 Sq.mm
4C X 4 Sq.mm
4C X 2.5 Sq.mm
3C x 16 Sqmm
3C x 10 Sqmm
3C x 6 Sqmm
3C x 4 Sqmm
3C x 2.5 Sqmm
Supplying and laying of following 1100 volts grade PVC insulated sheathed copper conductor armoured control cables in existing trenches cables trays, clamped on wall with suitable saddles, fixing bolts, including testing and commissioning.
2 core 2.5 Sq.mm PVC insulated copper conductor armoured control cables
4 core 2.5 Sq.mm PVC insulated copper conductor armoured control cables
4 core 1.5 Sq.mm PVC insulated copper conductor armoured control cables
10 core 2.5 Sq.mm PVC insulated copper conductor armoured control cables
12 core 2.5 Sq.mm PVC insulated copper conductor armoured control cables
Control Cables termination: Supplying of all materials and making terminations of control cable terminations for control cables above item complete with single brass compression glands, copper lugs etc. as required.
2 Core x 2.5 Sq.mm Cable
4 Core x 2.5 Sq.mm Cable
4 Core x 1.5 Sq.mm Cable
10 Core x 2.5 Sq.mm Cable
12 Core x 2.5 Sq.mm Cable
COPPER FLEXIBLE CABLES FOR UPS & EARTH
1CX70 sq mm PVC cu flexible cable
1CX50 sq mm PVC cu flexible cable
1CX10 sq mm PVC cu flexible cable
1CX6 sq mm PVC cu flexible cable
1CX4 sq mm PVC cu flexible cable
1CX2.5 sq mm PVC cu flexible cable
1CX1.5 sq mm PVC cu flexible cable
CABLE TRAY Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
100 mm width x 50 mm depth x 1.6 mm thickness
150 mm width x 50 mm depth x 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 62.50 mm depth X 2.0 mm thickness
600 mm width X 62.50 mm depth X 2.0 mm thickness
750 mm width X 62.50 mm depth X 2.0 mm thickness
900 mm width X 75 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
100 mm width x 50 mm depth x 1.6 mm thickness
150 mm width x 50 mm depth x 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 62.50 mm depth X 2.0 mm thickness
600 mm width X 62.50 mm depth X 2.0 mm thickness
750 mm width X 62.50 mm depth X 2.0 mm thickness
900 mm width X 75 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
100 mm width x 50 mm depth x 1.6 mm thickness
150 mm width x 50 mm depth x 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 62.50 mm depth X 2.0 mm thickness
600 mm width X 62.50 mm depth X 2.0 mm thickness
750 mm width X 62.50 mm depth X 2.0 mm thickness
900 mm width X 75 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Cross member"(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.
100 mm width x 50 mm depth x 1.6 mm thickness
150 mm width x 50 mm depth x 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
600 mm width X 50 mm depth X 2.0 mm thickness
750 mm width X 50 mm depth X 2.0 mm thickness
900 mm width X 75 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Reducer” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
100 mm width x 50 mm depth x 1.6 mm thickness
150 mm width x 50 mm depth x 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
600 mm width X 50 mm depth X 2.0 mm thickness
750 mm width X 50 mm depth X 2.0 mm thickness
900 mm width X 75 mm depth X 2.0 mm thickness
DANGER BOARD/SHOCK RESTRORATION CHART ETC.
Supplying and fix of standard shock restoration chart in heavy wooden frame with 3 mm thick plane glass.
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both side, and with inscription in single red colour on front side as required.
Providing and fixing M.V. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both side, and with inscription in single red colour on front side as required.
Supply & laying of insulating mats suitable for 1.1 KV Class A (2mm thick) as per IS15652-2006 (1.0 m wide) for LT Panel as approved by architect and complete in all respect.
Supply & laying of insulating mats suitable for 22 KV Class A (2.5mm thick) as per IS15652-2006 (1.0 m wide) for HT Panel as approved by architect and complete in all respect as approved by architect and complete in all respect.
Supply of First Aid Box including items like Gauze pads (at least 4 by 4 inches), Two large gauze pads (at least 8 by 10 inches), A box of adhesive bandages , One gauze roller bandage , Two triangular bandages , Wound cleaning agent , Scissors , At least one blanket , Tweezers , Adhesive tape , Latex gloves , Resuscitation equipment (such as resuscitation bag, or airway or pocket mask ), Two elastic wraps , A splint , Direction for requesting emergency assistance .
Supply of Rubber Hand gloves suitable for 22KV supply System as approved by architect and complete in all respect.
Supply & fixing of following fire extinguishers complete with high pressure control value, rubber braided discharge hose. Body of fire extinguishers should be CCE approved with IS: 2878 marking. The valve shall confirm to IS: 3224 as approved by architect and complete in all respect.
9 KG CO2 Fire Extinguishers.
10 KG DCP Fire Extinguishers.
50 liters foam type Fire Extinguishers with Troly.
EARTHING SYSTEM MAINTENANCE FREE EARTHING
Copper bonded rod with Low carbon steel, high tensile strength copper bonded rod with min 254 microns of copper plating, UL listed with company name marked on rod. Diameter- 17.2 mm, Length- 3 meters, Material- Copper Bonded, Coating thickness- 250 microns, min, Approvals- Tested acc. IEC / EN 62561-2, UL 467., 20 kg backfilled compound, - Material Carbon based backfill/earthing compound, Fulgurite formation test at direct lightning (10/350 μm), lightning long duration test at- 100C No fulgurites/Pass, Environmentally Friendly ROHS certified, Resistivity- < 0.12 ΩM, Complying Standard- IEC 62561-7 , Testing Approvals Certified from- NABL accredited Laboratories. StSt 316 grade clamp to terminate the load on earth electrode. Dimension- 160x35x3 mm., Poly plastic pit cover of material- Polymer Body & Cover, Product Code- HEP, Dimensions- 308 mm (L) x 308 mm (W) X 214 mm (H), Weight 2.5 kg (5.50 LBS).,
Supplying, receiving, laying, fixing, jointing, and terminating of the following Strips / wires in masonry treches / on walls / on cable tray / along the cable with suitable G.I. / Copper Clamps, screws etc. The wire shall be terminated with proper sockets, washers, bolts & nuts. All joints shall be rigid using double rivites as approved by architect and complete in all respect.
50 x 6 mm CU Strip with PVC sleeve
50 x 6 mm GI Strip
40 x 6 mm GI Strip
40 x 6 mm CU Strip
25 x 3 mm GI Strip
Providing & fixing 25mm x 5mm Copper strip on surface or in recess for connection etc as required.
Providing & fixing 25mm x 5mm G.I strip on surface or in recess for connection etc as required.
Providing and fixing 8 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
LIGHT FIXTURE AND FAN
Deep Recessed downlight luminaire with HPE (High-Performance Efficiency) LED (Light Emitting Diode) maximum system power: 15 W, minimum Luminous flux of luminaire 1650 lm, 110 Lm/w, Colour temperature of 4000 K, Neutral white, CRI > 80, R9>0, THD<5%, P.F>0.95, Driver Efficiency>88%, SDCM<3, 230 V constant current driver, 70% of luminous flux after 50,000 operating hours; Energy efficient LEDs, Direct light emission, Luminaire housing in aluminium, Polyester powder white coloured coat applied over a 5- stage pre-treatment, deep recessed Prismatic diffuser for homogenous light distribution, UGR<19, ZHLS (ZERO HALOGEN LOW SMOKE) wiring, Electronic control gear, Protection class II, IP 20 Ø = 175 mm, DA(Ø) = 160 mm, H = 59 mm.
LED recessed luminaire (2X2Panel Light) SM with LED(Light Emitting Diode) maximum system power: 25W, Luminous flux of luminaire 3500 lm, 140 Lm/w, colour temperature of 4000K, neutral white, 230V constant current driver, 70% of luminous flux after 50,000 operating hours, energy efficient LEDs, CRI>80, R9>0, THD<5%, P.F>0.95, Driver Efficiency>88%, SDCM<3, electronic control gear, direct light emission, sheet metal CRCA housing, polyester white powder coat applied over a 5-stage pre-treatment, Prismatic diffuser for glare-free uniform light distribution, UGR<19, Protection class I, IP40, surge protection of 2.5kV, L = 595mm, B = 595mm, H = 70mm
Pendant luminaire Alcove Up Dn with LED (Light Emitting Diode), maximum system power 28 W ( 14 W Up, 14 W Dn), minimum luminous flux of luminaire 3360 lm, 120 Lm/w, CRI>80, R9>0, THD<5%, P.F>0.95, Driver Efficiency>88%, SDCM<3, colour temperature of 4000 K, Neutral white, 230V constant current driver, 70% of luminous flux after 50,000 operating hours, energy-efficient LEDs, luminaire profile in aluminium, Plastic moulded end caps, Polyester powder Aluminium white coloured coat applied over a 5- stage pre-treatment, Deep recessed high-efficiency glare-free snap-fit micro-prismatic diffuser for homogeneous light distribution, UGR<19, ZHLS (Zero Halogen Low Smoke) internal wiring, integral electronic control gear, adjustable suspender, Protection class I, IP20, L = 1199 mm, B = 75 mm, H = 90 mm, PL max = 1500 mm.
COB based LED recessed adjustable directional downlight , with maximum system power: 35 W, minimum Luminous flux of luminaire 3500 lm, 100 Lm/W, Colour temperature of 4000 K, Neutral white, CRI > 80, R9>0, THD<5%, P.F>0.95, Driver Efficiency>88%, SDCM<3, 230V constant current driver, 70% of luminous flux after 50,000 operating hours; energy-efficient LEDs, direct light emission, housing in die-cast aluminium, Polyester powder white coloured coat applied over a 5-stage pre-treatment ceiling trim, deep recessed clear glass cover with aluminium reflector and a beam angle of 25°, UGR<16, ZHLS (ZERO HALOGEN LOW SMOKE) wiring, electronic control gear, Protection class II, IP 40, Ø = 162 mm, DA(Ø) = 150 mm, H = 162 mm.
Pendant luminaire Slash S with HE-High Efficiency LED (Light Emitting Diode), maximum system power: 25W, minimum luminous flux of luminaire 2750 lm, 110 Lm/W, colour temperature of 4000K, CRI>80, R9>0, THD<5%, P.F>0.95, Driver Efficiency>88%, SDCM<3, 230V constant current driver, 70% of luminous flux after 50,000 operating hours, energy efficient LEDs, direct light emission, luminaire profile powder coated white, Prismatic diffuser for homogenous light distribution, Driver replacement from the top without opening the optical part, UGR<19, ZHLS(ZERO HALOGEN LOW SMOKE) internal wiring, integral electronic control gear, Protection class I, IP40, L = 1175 mm, B = 52 mm, H = 64 mm, PH=1500mm.
Recessed with Trim luminaire Slash S with HPE (High Performance Efficiency) LED (Light Emitting Diode) maximum system power: 25W, minimum luminous flux of luminaire 2750 lm, 120 Lm/W, Colour temperature of 4000 K, Neutral white, CRI > 80, R9>0, THD<5%, P.F>0.95, Driver Efficiency>88%, SDCM<3, 230 V constant current driver, 70 % of luminous flux after 50,000 operating hours, Energy efficient LEDs, Direct light emission, Luminaire profile in aluminium, Polyester powder white coloured coat applied over a 5- stage pre-treatment, Prismatic snap fit diffuser for homogenous light distribution, Driver replacement from the bottom without removing the fixture from ceiling, UGR<19, ZHLS (ZERO HALOGEN LOW SMOKE) internal wiring, Electronic control gear, Protection class I, IP 40, L = 1187 mm, B = 64 mm, H = 64 mm, L (ET) = 1175 mm, B (ET) = 52mm
LED strip (flexible) with 60 LEDs per meter, 10W per Meter, 4000K, 2835 SMD package with thermal tape of high thermal convection factor, beam angle of 120°, MacAdum 5, constant voltage driving circuit, L = 1000mm, H = 10mm, B = 1.4mm.
Pendant luminaire Ring with HPE (High Performance Efficiency) LED (Light Emitting Diode) maximum system power: 60 W, minimum Luminous flux of luminaire 6000 lm, Colour temperature of 4000 K, Neutral white, CRI > 80, SDCM<3 , R9>0 230 V constant current driver, 70% of luminous flux after 50,000 operating hours; Energy efficient LEDs, Direct light emission, Luminaire profile in aluminium, Polyester powder black coloured coat applied over a 5- stage pre-treatment, Prismatic diffuser for a homogenous light distribution, ZHLS (ZERO HALOGEN LOW SMOKE) internal wiring, Electronic control gear, Protection class I, IP20, Ø = 980 mm, W = 100 mm, H =67 mm, PL = 1500 mm.
COB based wall mounted luminaire Frost, maximum system power: 2x12 W, minimum luminous flux of luminaire 2400 lm, colour temperature of 4000 K, Neutral white, CRI > 80, 70% of luminous flux after 50,000 operating hours, 230V constant current driver, direct-indirect light emission, aluminium housing polyester powder coated white applied over a 5-stage pre-treatment, clear glass cover with reflectors and a beam angle of 24°, integral electronic control gear, Protection class II, IP 20 Ø = 75 mm, H = 300 mm, B = 90 mm.
Surface Mounted luminaire Tube with HPE (High-Performance Efficiency) LED (Light Emitting Diode) maximum systempower: 9 W,minimum Luminous flux of luminaire 900 lm, Colour temperature of 4000 K, Neutral white, CRI > 80, R9>0 230 Vconstant current driver, 70 % of luminous flux after 50,000 operating hours, Energy-efficient LEDs, Direct light emission,Luminaire profile in aluminium, Polyester powder whitecoloured coat applied over a 5- stage pre-treatment, snap-fitsatin diffuser for homogenous light distribution, ZHLS (ZEROHALOGEN LOW SMOKE) internal wiring, Electronic controlgear,Protection class I, IP 40, MacAdam 3, T.H.D ≤ 10%, driverefficiency ≥ 88%, surge protection of 2.5 kV, PF = 0.95
Wall Mounted luminaire Bulkhead with HPE (High-Performance Efficiency) LED (Light Emitting Diode) system power: 10W, Luminous flux of luminaire 800 lm, Colour temperature of 4000 K, Neutral white, CRI > 80, 230 V constant current driver, 70% of luminous flux after 50,000 operating hours; Energy efficient LEDs, Direct light emission, Luminaire housing in aluminium, Polyester powder grey coloured coat applied over a 5- stage pre-treatment, Opal diffuser for homogenous light distribution, ZHLS (ZERO HALOGEN LOW SMOKE) internal wiring, Electronic control gear, Protection class II, IP 65, L = 215 mm, B = 132 mm, H = 55 mm.
LED Recessed directional spotlight JUPITER with LED(Light Emitting Diode) maximum system power: 15W, minimum luminous flux of luminaire 1500lm, 230V constant current driver, 70% of luminous flux after 50,000 operating hours; energy efficient LEDs, colour temperature of 4000K, neutral white, direct light emission, beam angle of 20°, luminaire part adjustable, polyester powder coat applied over a 5-stage pre-treatment, electronic control gear, Protection class II, IP20, MacAdam 3, T.H.D≤ 10%, driver efficiency ≥ 88%, surge protection of 2.5kV, L = 90mm, B = 90mm, DA(ø) = 80mm, ET = 65mm
Ceiling mounting downlight Zing with LED (Light Emitting Diode), maximum system power of 15W, minimum luminous flux of luminaire 1650 lm, 110 Lm/W, colour temperature of 4000K, neutral white, CRI > 80, R9>0, P.F>0.95, Driver Efficiency>88%, SDCM<3, 70% of luminous flux after 50,000 operating hours, 230V constant current driver, direct light emission, housing in die-cast aluminium, polyester powder coated white applied over a 5 stage pre-treatment, opal protuded for uniform illumination, LG7 Complaince, integral electronic control gear, Protection class II , IP 20, Ø = 170 mm, H = 43 mm
Pendant luminaire with LED(Light Emitting Diode) maximum system power: 26W, minimum luminous flux of luminaire 2730lm, a colour temperature of 4000K, neutral white, CRI>80, 230V constant current driver, 70% of luminous flux after 50,000 operating hours; energy efficient LEDs, direct light emission, aluminium housing powder coated black, integral electronic control gear, SDCM <3, T.H.D≤ 10%, driver efficiency ≥ 88%, surge protection of 2.5kV, Protection class I, IP20, Ø =427mm, H = 227mm,
Supply of 60W LED Street Light delivering minimum system lumen of 7200 lm & the luminaire shall be with system efficacy ≥ 120 lm/W. Aluminium die cast powder coated & High purity PC lenses. The operating CCT shall be 5700K with CRI of ≥70. The luminaire shall be BIS Registered with electronic driver with input voltage range of 150-300V, IP 66, IK 10, 50000 Hrs LED life with L70 Criteria. The LED driver shall be easily available in India for repair and service. The LED shall be SMD type. The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacturer along with Photo Biological Safety Standard. 4KV internal surge protection in both Common Mode and Differential Mode.
Supply of 45W LED Post Top Light delivering minimum system lumen of 4500 lm & the luminaire shall be with system efficacy ≥ 100 lm/W. Aluminium die cast powder coated & High purity PC lenses. The operating CCT shall be 5700K with CRI of ≥70. The luminaire shall be BIS Registered with electronic driver with input voltage range of 150-300V,IP 66,IK 07, 50000 Hrs LED life with L70 Criteria. The LED driver shall be easily available in India for repair and service. The LED shall be SMD type. The luminaire shall be with following certifiactions: LM79 & LM80 issued by LED manufacturer along with Photo Biological Safety Standard.
Supply of 45W LED Gate Light delivering minimum system lumen of 4275 lm & the luminaire shall be with system efficacy ≥ 90 lm/W. Aluminium die cast powder coated housing with Acrylic diffuser. The operating CCT shall be 5700K with CRI of ≥70. The luminaire shall be BIS Registered with electronic driver with input voltage range of 150-270V,IP 65,IK 05, 50000 Hrs LED life with L70 Criteria. The LED driver shall be easily available in India for repair and service. The LED shall be SMD type. The luminaire shall be with following certifiactions: LM79 & LM80 issued by LED manufacturer along with Photo Biological Safety Standard.
Supply of LED surface mounted tube light.
15 Watt Klite Rado Bollard Light.
300MM Dia Plastic Body Exhaust Fan. Minimum fan power required : 0.37 KW
450MM Dia MS body heavy duty Exhaust Fan . Minimum fan power required : 0.37 KW
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored).
LAN SYSTEM
Supply, Installation, Testing & Commissioning of Core Switch 1RU cchassis with 24 SFP+ users, 2 SFP+ uplinks or VFL and 2 QSFP28 ports. QSFP28 ports operate as 40/100G-4x10/25G. Back to front cooling. Includes dual AC power supplies.with 05 year support & warranty
Supply, Installation, Testing & Commissioning of Supply of Gigabit Ethernet 1RU chassis with 24 10/100/1000 BaseT ports and 2 1G* RJ45/SFP+ combo, 2 1G/10G SFP+ uplink/VFL ports. I with a power cord, .with 05 year support & warranty Stacking Cables etc as required
Supply, Installation, Testing & Commissioning of Supply of Gigabit Ethernet 1RU chassis with 24 PoE 10/100/1000 BaseT ports and 2 1G* RJ45/SFP+ combo, 2 1G/10G SFP+ uplink/VFL ports. Includes an internal AC power supply 380W power budget) with a power cord, .with 05 year support & warranty Stacking Cables etc as required (for IP Phones)
Supply, Installation, Testing & Commissioning of Supply of 10 Gigabit optical transceiver SFP+). Supports monomode fiber over 1310nm wavelength nominal) with an LC connector. Typical reach of 10Km.with 05 year support & warranty
Supply of 10 Gigabit direct attached cable (DAC, uplink/stacking) 1m, SFP+ with 05 year support & warranty
Supply, Installation, testing and commissioning of UTP 4 pair 23 AWG CAT 6A LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required conforming to the following standards like ANSI TIA/TIA 568.2-D, ISO/IEC 11801. Cable Dia 7.6 mm with bending radius - 4 X Cable Diameter, pulling force is 11.5Kg. Operates at frequency of 500 Mhz
Supply, Installation, testing and commissioning of 24 port Cat 6A 19" Modular Toolless Patch Panel (loaded) enable all possible combinations of the various types of cable (UTP, FTP, SFTP) mounted on the same panel by using various toolless connector blocks/modules. Have a metal structure enabling them to be durably fixed to the uprights of the 19” chassis and assuring automatic grounding between toolless RJ-45 connectors, the panel, and the 19” uprights of the enclosure. Include rear cable support with plastic cable guides to hold cable without need for cable ties. Include quick mounting system to mount the panel into the 19” rails without use of cage-nuts. These may be used to secure the connections of wifi access points, IP cameras, servers, or other critical devices. Front Removal IO's option for maintenance and trouble shooting with 6 Different Colours Labels for Labelling & Identification of Individual Ports. Tested and guaranteed under dual circuit IEEE PoE++ more than 90W for up to 2500 on-load connections / disconnections.
SITC of CAT6A UTP 26 AWG Patch Cord - 1 mtr with cross separator , Manufactured from stranded wires for longer flex-life , Minimum length of 1m, and maximum length of 5m Conforming to the following standards like Smoke density: Series IEC 61034 / IEC 61034-2, EN 61034-2, IEC 60754/IEC 60754-2, EN 60754-2, IEC 60332-1/60332-1-2, UL VW-1 with tensile strength >50N, Number of Insertion upto 2500 Duty Cycle
SITC of CAT6A UTP 26 AWG Patch Cord - 2 mtr with cross separator , Manufactured from stranded wires for longer flex-life , Minimum length of 1m, and maximum length of 5m Conforming to the following standards like Smoke density: Series IEC 61034 / IEC 61034-2, EN 61034-2, IEC 60754/IEC 60754-2, EN 60754-2, IEC 60332-1/60332-1-2, UL VW-1 with tensile strength >50N, Number of Insertion upto 2500 Duty Cycle
Supply of Wall Mount, assembled, UL Certified rack (RAL 7035 in Pastal fine texture OR RAL 9005 in Black fine texture) with Sheet steel riveted metal frame, Top and bottom cover with brush cable entries, confirming to following standards - IEC 60529 EN 60529 (IP20), IEC 62262 EN 62262 (IK08), DIN 41494, EIA 310, IEC 60297, Rack including accessories like Horizontal PDU, Metal Cable manager, Hardware packet and Cantilever Shelf should be from same OEM 15U (600*500mmD) with Std Acc(
SITC of RJ-45 Connectors / Modular Plugs Pack of 100
Supply, Installation, testing and commissioning of Cat6A Tool less Information outlet for Data & Voice. Cat6 U/UTP RJ45 socket with built in crimping mechanism with capability of retermination without refreshing the wires. Toolless RJ45 Information outlet with insertion cycle (in & out) upto 2500 times (I/O) along with front side Label holder and transparent shutter. The Information Outlet connector shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors shall be compatible as per IEEE 802.3bt standard for POE++ application
Supply of Floor Stand UL certified rack with Multi hollow extrusion Aluminium profile frame, Top and bottom cover with provision of either brush cable entry or cable entry holes with rubber grommets, Front single door with Glass/ Mesh and rear double door with mesh, Static load bearing capacity of Upto 1200KG., confirming to following standards - IEC EN 60529, IEC EN 62262, ISO 9001:2008, ISO 14001: 2015, ISO 45001: 2018, Salt spray test according to ISO 9227 (NSS test) for 250 Hours, Colour -Black of RAL 9005 with fine texture 42U (600*800mmD) with Std Acc
Supply of Floor Stand UL certified rack with Multi hollow extrusion Aluminium profile frame, Top and bottom cover with provision of either brush cable entry or cable entry holes with rubber grommets, Front single door with Glass/ Mesh and rear double door with mesh, Static load bearing capacity of Upto 1200KG., confirming to following standards - IEC EN 60529, IEC EN 62262, ISO 9001:2008, ISO 14001: 2015, ISO 45001: 2018, Salt spray test according to ISO 9227 (NSS test) for 250 Hours, Colour -Black of RAL 9005 with fine texture 32U (600*800mmD) with Std Acc
Metal 19” pre-equipped fibre optic drawers, 4 cable entries, supplied with screw fixing kit, 2 cable glands (Ø 13.5 and 16 mm), coiling system and splicing cassette.Panel and optical ports marked on dedicated marking area.Sliding: end stop at a 30° angle for easier wiring.
Supplying & Fixing of Fiber Optic LC style fully loaded Patch Panel (FOPP), 19" Rack Mount ,Shall have all accessories including coupler plates pre loaded with 12 Nos of LC couplers SM with all accessories complete in all respect. Pigtails Should Complie to ITU-G657.B-Bend insestive fiber.
Supplying & Fixing of Fiber Optic LC style fully loaded Patch Panel (FOPP), 19" Rack Mount ,Shall have all accessories including coupler plates pre loaded with 48 Nos of LC couplers SM with all accessories complete in all respect. Pigtails Should Complie to ITU-G657.B-Bend insestive fiber..
Supplying & Fixing of SM Fiber Optic Patch Cable (LC-LC), 3 Mtrs. Long, , LSZH,Shall have LC-LC Connector connectors at the ends, Conform to IEC, EIA-TIA, and Telecordia performances requirements,RoHS, REACH & SvHC compliant complete in all respect..
Supply, Installation, testing and commissioning of Single Mode OS1/OS2 SC-SC Duplex Fiber Patch Cord LC-LC - 3 mtrs. Conform to IEC 61754-4,61300-3-4,61300-3-34,61300-3-6,61300-2-1/2/4/5 EIA-TIA, G.657.A2 and Telecordia performances requirements
Supply, laying and fixing of 6 core OS1/OS2 - loose tube outdoor/corrugated steel tape with Unitube construction Crush Resistance 2000N with 8.5 mm Diameter and confirming to IEC/EN 60793-2-50 class B1.3 ITU G.652.D EN 50 173-1:2007 ISO/IEC 11801:2002 ISO/IEC 24702:2006- through existing GI/HDPE/ Hume pipe or on cable trays inside the cable duct including all necessary fixing accessories e.g. cable ties, hardware etc.
FIRE ALARM SYSTEM & PA SYSTEM, TALK BACK (ADDRESSABLE TYPE)
4 -loop - With Digital Voice Command Center ( Expaandable to 16 Loop)
Intelligent field mountable 100W amplifier with onboard power supply and Battery backup & support 8 speaker zones.The unit should be UL listed and FM approved complete as per specifications.
Supply,Installation,Testing & Commissioning of customizable 500X500mm Mimic panel with min 20 LEDs projected on floor/area for easy identification of the sector/zone in fire condition & Installed at control center as per IS standards
Supply, installation and testing & commissioning of Active Repeater Panel with backlit Liquid Crystal Display & Reset, Silence & Acknowledge function. The unit should be UL listed and FM approved complete as per specifications.
Supply,Installation,Testing & Commissioning of Addressable Muliti-sensor Detector (smoke & heat) with following features Smoke Sensitivity min 1.5% obs/ft for detecting Grey smoke. Dual Thermistors for Thermal activation at 57 Deg C Field adjustable min 3 levels of Alarm Setting Addressing using basic hand tools Bicolor LED with 360 deg view. The unit should be UL listed and FM approved complete as per specifications. Above False Ceiling.
Supply,Installation,Testing & Commissioning of Addressable Smoke Detector with following features Smoke Sensitivity min 1.5% obs/ft for detecting Grey smoke. Field adjustable min 3 level of Alarm Setting Addressing using basic hand tools Bicolor LED with 360 deg view The unit should be UL listed and FM approved complete as per specifications. Below False Ceiling.
Supply,Installation,Testing & Commissioning of Addressable Rate of Rise Heat Detector with following features Rate of rise detection 8.3 Deg C Thermal activation at 57 Deg C Addressing using basic hand tools Bicolor LED with 360 deg view.The unit should be UL listed and FM approved complete as per specifications.
Supply,Installation,Testing & Commissioning of Addressable Manual Call point with following features Bicolor LED monitor the heath status of the device LED Blinking in normal state & get steady on activation Test Key for manual testing Addressing using basic hand tools The unit should be UL listed and FM approved complete as per specifications.
Supply,Installation,Testing & Commissioning of Addressable Control Module for Notification devices with following features Supervised NAC output rated at 24v DC, 2A LED Blinking in normal state & get steady on activation Supervised power input port Addressing using basic hand tools The unit should be UL listed and FM approved complete as per specifications.
Supply,Installation,Testing & Commissioning of Addressable Output Module for 3rd Party integration with following features Dual Pot. free contact rated 24v DC, 2A LED Blinking in normal state & get steady on activation Addressing using basic hand tools The unit should be UL listed and FM approved complete as per specifications.
Supply,Installation,Testing & Commissioning of Addressable Input Module for 3rd Party integration with following features Monitor pot. free contacts LED Blinking in normal state & get steady on activation Addressing using basic hand tools The unit should be UL listed and FM approved complete as per specifications.
Supply,Installation,Testing & Commissioning of Isolator Module with following features Isolate short circuits with automatic resetting arrangement LED Blinking in normal state & get steady on activation Addressing using basic hand tools The unit should be UL listed and FM approved complete as per specifications.
Supply,Installation,Testing & Commissioning of Hooter cum Strobe with following features Sound level 80 dBA @ 3m for Audible annunciation Visual - 115cd flashing at 1 Hz Wall/Ceiling Mountable The unit should be UL listed complete as per specifications
Supply,Installation,Testing & Commissioning of 2W Multi-Tap (0.25W; 0.5W; 1W; 2W), Ceiling Mount Speakers. The speakers shall be of same make as that of the Control Panel & Amplifiers. They shall be compatible with supplied Amplifiers and shall work on 70.7Vrms. UL Listed
Supply,Installation,Testing & Commissioning of 2W Multi-Tap (0.25W; 0.5W; 1W; 2W), Wall Mount Speakers. The speakers shall be of same make as that of the Control Panel & Amplifiers. They shall be compatible with supplied Amplifiers and shall work on 70.7Vrms. UL Listed
Telephone Talkback
Supply,Installation,Testing & Commissioning of Fire Fighter's Telephone Communication System Capable of supervising upto 72 telephone circuit support Min 10 concurrent communitation on the network The unit should be UL listed and FM approved complete as per specifications.
Supply,Installation,Testing & Commissioning of Addressable Fire Fighter's Telephone Jack with suitable supervised module for two way communication between Remote Fire Fighter & Fire Command Center. UL Listed
Supply,Installation,Testing & Commissioning of Fire Fighter's Telephone Handset for two way communication between Remote Fire Fighter & Fire Command Center
Supplying & laying of 2x1 .5 sqmm fire survival armoured cable, 600/1 OOOV rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.
Supply and drawing of 2 C X 1.5 Sq mm multi stranded twisted shielded FRLS Copper cable. (For Speakers)
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
32 mm dia.
25 mm dia.
20 mm dia.
Supplying, installing, testing and commissioning approved make 20 mm dia. PVC flexible conduits on ceiling / wall / floor etc. complete with accessories like, Junction boxes, Collars, Bends etc.
ACCESS CONTROL SOLUTION
Readers - Supply, installation, testing & commissioning of 13.56MHz, ISO 14443A/B Smart Card readers, Read Range 3" with weigand data format, UL, CE, FCC listed, Operating Temp 0 to 60 Deg C as per specification suitable for mounting on metal surface/metal frames or wooden frames wall or as required based on site conditions.
Cards - Supply and commisioning of 13.5MHz, ISO 14443A Smart cards, 1KB (Kilo byte) memory, ISO Thickness, Smart Cards with the possibility of printing the company details on its facia using sublimation method.
Access Control - Accessories - Supply, installation, testing and commissioning of Feed back type electromagnetic Lock (fail safe type) of 5000 Newtons holding force , with door ajar alarm buzzer connectivity for the following type doors :
Single Leaf door
Double Leaf door
12V/5V Door Ajar Buzzer with timer circuit suitable to be connected to above EM locks
Supply installation, testing, commissioning of Green ABS plastic Resetable type Emergency Break Glass Units. - ISI marked
Access Controller - Supply Installation of 2 reader intelligent controller with onbaord LAN/Web server, 8 supervised Inputs and 4 form C relay outputs, with 32-bit CPU, 32 MB Flash memory, 16 MB SDRAM memory, Real-time clock, supports 8 card formats and 8 facility codes, 10,000 card holder and 20,000 offline event buffer, CE, FCC Listed, Along with cabinet and power support and 3 hrs battery backup.
Softwares - Supply installtion testing commissioining of Access Control Software Supporting minimum 512 online readers, 100,000 card holders, 01 concurrent Clients/User expandable to 05, LDAP based and Application logon users, MS SQL Based, inbuild Guard Tour module, various Reports with time stampping nearest to seconds, unlimited Timezones, various card attributes VIP, Normal, integration with Fire Alarm System to free open/Lock designated door in case fire.
Supply installation testing & commissioning of web based Time & Attendance various T&A reports such as Attendance details with IN-Out time and total Manhours, overtime, Leave Management, out duty, online leave application and approval as a min.
CABLING Supply installation testing & commissioning of PVC insulated and PVC sheathed 8 core 0.5 sq.mm. twisted pair standard cable with PVC/steel conduit as required as per specification a
Supply installation testing & commissioning installation of PVC insulated and PVC sheathed 4 core 1.5 sq.mm. copper condcutor cable with PVC/steel conduit as required as per specification
Supply installation testing & commissioning, of CAT 6 cable with PVC/steel conduit as required as per specification
UPS SYSTEM :
Design, manufacturing, assembly, testing at works, supply, receiving at site, erection, testing and commissioning of true-online double conversion VFI Technology UPS, 3Ph. AC input & 3Ph AC output UPS system suitable for 415VAC, 50Hz supply, variation +/-1% , PF 0.8 as required as per specification and consisting of following: Input range should be 312V AC-467V AC at full lod and 208V -467 V at Half Load, in case the voltage range does not meet the specified range, cost of servo stabilizer should be added. IGBT Rectifier Modules to achieve less than 5% Input Current distortion and greater than 0.98 PF at Input at all loads and THDv<2% at Output Fully microprocessor based with diagnostics capability. Dual Input (Separate Input for rectifier and separate input for Bypass) Required quantity and details of UPS are as mentioned below. Location details and mode of operation of UPS shall be as per SLD. Design, manufacturing, testing at works, supply, erection, testing and commissioning of One sets of SMF VRLA battery with each UPS capacity as mentioned below, having back up time as mentioned below at full load, with interconnecting cables, cabinets and standard accessories as per specification and as required for the UPS system. (12V Cells) Battery shall be external type with rack and suitable for 15 minute backup with minimum VAH of 30240 on 100% load. Battery to be included in UPS cost UPS shall be compatible for Parallel operation and kit shall be supplied with UPS. Please refer technical specfication for more details
100 KVA UPS.
15 KVA UPS.
EMERGENCY SIGNAGES :
Providing and Fixing of Green LED emergency exit signage single Sided sign type fixed on wall above the door. 2W LED Emergency Backup of minimum 2 hours
Providing and Fixing of Green LED emergency exit signage double Sided Ceiling hung sign type made of powder coated MS housing and acrylic sheet indicator with light source 2W LED Emergency Backup of minimum 2 hours.
Providing, fixing and commissioning of single sided photoluminescent signs. Primary and secondary route to be marked. Rigid Photo luminescent based Glow-in-the-dark rigid sheet with high intensity luminous properties enclosed in a transparent weather-proof UV stabilized coated sheet with UV screen printing by imported links, Thickness : 1 mm, Service Temp. : -10 to + 60°C, Application : Suitable for INDOOR use only, Surface Colour : Greenish Yellow, Visibility : Glow visible up to> 24 hours in total darkness, Properties : *Fungistatic *Non-radioactive *Contains no lead or Phosphorus * No health or environmental problem *Simple to install & easy to maintain, can be screwed or just peel off to stick *Self-Extinguishing
1) Providing, fixing and commissioning of single sided non Illuminated signs as per design submitted. Sign made in photoluminescent sheet. Rigid Photo luminescent based Glow-in-the-dark rigid sheet with high intensity luminous properties enclosed in a transparent weather-proof UV stabilized coated sheet with UV screen printing by imported links, Thickness : 1 mm, Service Temp. : -10 to + 60°C, Application : Suitable for INDOOR use only, Surface Colour : Greenish Yellow, Visibility : Glow visible up to> 24 hours in total darkness, Properties : *Fungistatic *Non-radioactive *Contains no lead or Phosphorus * No health or environmental problem *Simple to install & easy to maintain, can be screwed or just peel off to stick *Self-Extinguishing
1) Providing, fixing and commissioning of single sided non Illuminated signs as per design submitted. Sign made in photoluminescent sheet. Rigid Photo luminescent based Glow-in-the-dark rigid sheet with high intensity luminous properties enclosed in a transparent weather-proof UV stabilized coated sheet with UV screen printing by imported links, Thickness : 1 mm, Service Temp. : -10 to + 60°C, Application : Suitable for INDOOR use only, Surface Colour : Greenish Yellow, Visibility : Glow visible up to> 24 hours in total darkness, Properties : *Fungistatic *Non-radioactive *Contains no lead or Phosphorus * No health or environmental problem *Simple to install & easy to maintain, can be screwed or just peel off to stick *Self-Extinguishing (Ground floor)
1) Providing, fixing and commissioning of single sided non Illuminated signs as per design submitted. Sign made in photoluminescent sheet. Rigid Photo luminescent based Glow-in-the-dark rigid sheet with high intensity luminous properties enclosed in a transparent weather-proof UV stabilized coated sheet with UV screen printing by imported links, Thickness : 1 mm, Service Temp. : -10 to + 60°C, Application : Suitable for INDOOR use only, Surface Colour : Greenish Yellow, Visibility : Glow visible up to> 24 hours in total darkness, Properties : *Fungistatic *Non-radioactive *Contains no lead or Phosphorus * No health or environmental problem *Simple to install & easy to maintain, can be screwed or just peel off to stick *Self-Extinguishing (Second floor)
1) Providing, fixing and commissioning of single sided non Illuminated signs as per design submitted. Sign made in photoluminescent sheet. Rigid Photo luminescent based Glow-in-the-dark rigid sheet with high intensity luminous properties enclosed in a transparent weather-proof UV stabilized coated sheet with UV screen printing by imported links, Thickness : 1 mm, Service Temp. : -10 to + 60°C, Application : Suitable for INDOOR use only, Surface Colour : Greenish Yellow, Visibility : Glow visible up to> 24 hours in total darkness, Properties : *Fungistatic *Non-radioactive *Contains no lead or Phosphorus * No health or environmental problem *Simple to install & easy to maintain, can be screwed or just peel off to stick *Self-Extinguishing (Third floor)
1) Providing, fixing and commissioning of single sided non Illuminated signs as per design submitted. Sign made in photoluminescent sheet.
Exit signage to be added at each staircase , signage to be made in photoluminescent sheet. Rigid Photo luminescent based Glow-in-the-dark rigid sheet with high intensity luminous properties enclosed in a transparent weather-proof UV stabilized coated sheet with UV screen printing by imported links, Thickness : 1 mm, Service Temp. : -10 to + 60°C, Application : Suitable for INDOOR use only, Surface Colour : Greenish Yellow, Visibility : Glow visible up to> 24 hours in total darkness, Properties : *Fungistatic *Non-radioactive *Contains no lead or Phosphorus * No health or environmental problem *Simple to install & easy to maintain, can be screwed or just peel off to stick *Self-Extinguishing
POLES
Supplying, Installation , testing and commissioning of outdoor lighting with fabricated pole made of MS pipe ( medium class) complete with base plate, luminaire bracket arm bed concrete foundation in 1:3: 6 ratio (1cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) including excavation and refiling , painting of Poles with one coat of primer and two coats of approved synthetics enamel paint etc. as required as approved by architect and complete in all respect. 6 mtr.high steel tubular decorative pole with 450 x 450 x 10 mm thick base plate. Outside dia and thickness of sections of the pole shall be at bottom 114.3mm x 5.4mm , middle 88.9mm x 4.85mm & top 76.1mm x 3.25mm.
Double arm decorative Pole (Apprx. Weight 85kg) as above in sr no.444
4.0 meter, Mild steel decorative Pole for post top lantern (ISI marked) with 76.1mm O/D and 3.65 mm thickness and with 300 x 300 x6 mm thick base plate. as above in sr no.444
Supplying and embedding following dia G.I.pipe (meduim class) inpole collar / foundation (during casting) for cable entry including bending the pipe to the required shape complete as required.
32 mm dia (for Cable entry to pole box.)
40 mm dia (for Gate light )
POLES MOUNTING BOXES : Supply and fixing of Thermoplastic type water proof pole mounting boxes of size 205 x 255 mm x 112 mm , with cover and Gasket with cablel entry knock outs, 4 way 20A connectors mounted inside box etc.as per design including mounting arrangements. (Box depth 112mm)
LIGHTINING ARRESTORS
Parallel Connectors for (700mm air terminal) connecting two conductors in parallel manner. Material- StSt, with clamping range- Rd / Rd 7-10 mm & Complied as per Standard EN 62561-1.
Air-termination rod having length- 3000 mm, of Material- AlMgSi, of Diameter Ø 16 mm, & Complied as per Standard EN 62561-2.
Side Wall Clamp for air terminal,
Air-termination rod clamps for connecting air-termination rods with one or two conductors. Material of clamp Al, with clamping range of air-termination rod 16 mm and Clamping range of conductor Rd 2x 8-10 mm, & Complied as per Standard EN 62561-1.
Universal connector of Material- StSt, with clamping range- 8-10mm, with truss head screw M10x35 mm & Complied as per Standard EN 62561-1.,
Roof Conductor of Diameter Ø- 8 mm, Cross-section- 50 mm2, of Material- AlMgSi & Complied as per Standard EN 62561-2.,
Conductor holder for Parapet wall/Side wall. Having height- 16 mm, Thread of conductor holder- M8, Material of conductor holder- SS, Conductor leading- loose, Conductor holder support Rd- 8 mm. With accessories Screw and Gitty, Material SS (M5 x 50mm)
Roof conductor holder FB2 for flat roofs with concrete block-C35/45 with double conductor holder- Rd 8 mm fixed, Dimension- 141 x 86 x 70 mm
Down conductor Down Conductor of Diameter Ø- 8 mm, Cross-section- 50 mm2, of Material- AlMgSi & Complied as per Standard EN 62561-2.,
Conductor holder for Parapet wall/Side wall. Having height- 16 mm, Thread of conductor holder- M8, Material of conductor holder- SS, Conductor leading- loose, Conductor holder support Rd- 8 mm With accessories Screw and Gitty, Material SS (M5 x 50mm)
UNI Disconnecting Clamps with intermediate plate for round and flat conductor of Material- StSt, Material thickness- 2.5 mm, with clamping range- Rd / Fl 8-10 / 30 mm, & Complied as per Standard EN 62561-1.,
For Earthing GI flat (25x6mm) for interconnection of earth pit & termination to earth pit Weight 1.2 kg/m (approx.) Cross Section 150 mm2 ,Coating thickness Avg. 70 microns. As per IEC 62561-2 ,Material Hot dipped Galvanized Iron
GI strip holder of material- Dow moulded compound, having height- 19mm, Slot Size- 25x6 mm.
Copper bonded rod with Low carbon steel, high tensile strength copper bonded rod with min 254 microns of copper plating, UL listed with company name marked on rod. Diameter- 17.2 mm, Length- 3 meters, Material- Copper Bonded, Coating thickness- 250 microns, min, Approvals- Tested acc. IEC / EN 62561-2, UL 467.,
20 kg backfilled compound, - Material Carbon based backfill/earthing compound, Fulgurite formation test at direct lightning (10/350 μm), lightning long duration test at- 100C No fulgurites/Pass, Environmentally Friendly ROHS certified, Resistivity- < 0.12 ΩM, Complying Standard- IEC 62561-7 , Testing Approvals Certified from- NABL accredited Laboratories.
Steel 316 grade clamp to terminate the load on earth electrode. Dimension- 160x35x3 mm.,
Poly plastic pit cover of material- Polymer Body & Cover, Product Code- HEP, Dimensions- 308 mm (L) x 308 mm (W) X 214 mm (H), Weight 2.5 kg (5.50 LBS).,
GI flat (25x6mm) for interconnection of earth pit & termination to earth pit Weight 1.2 kg/m (approx.) Cross Section 150 mm2 ,Coating thickness Avg. 70 microns. As per IEC 62561-2 ,Material Hot dipped Galvanized Iron
Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric.
Supply & fixing of 5Kg clean Agent Ceiling suspended Auto Fire extinguisher (UL Listed HFC-236fa agent)
BUILDING AUTOMATION SYSTEM:
BMS Computer System: server grade Pentium Core with 3GHz minimum CPU speed, minimum of 8 GB RAM, 520GB HDD, optical Mouse, 106 keys keyboard, 10/100 Mbps Ethernet card ,USB connection & internal modem, 21" colour graphics TFT monitor & Original Windows 11 loaded.
BMS System Software : Web Based Graphical Software meeting the requirements in the Given I/O Summary & technical specifications including configuration and facility to create / provide the graphic mapping for all I/O Summary points, animate the Graphics, Navigation between pages, display of logs, changing the time zones, popup alarms, configurable password protection for Building Mgmt System as per Specifications. Software shall be able to communicate with Lon works, Bacnet, Modbus devices simultaneously, with unlimited user license capacity.
Hardware Interface for Modbus RTU Unit, Open Protocol Software Integration for following :-Chiller System Interface on BACnet/Modbus MSTP - 3 Nos. (20 I/O's per Chiller) Secondary Pumping System on Modbus RTU - 3 Nos.(20 points / Pump) VFD on Modbus RTU - 2 Nos.(12 points / VFD) UPS on Modbus RS485 - 3 No.(30 points/unit) FAS Panel on Bacnet / Modbus - 600 points
DDC Controller
DDC Controller with I/O module, expandable upto 192 points, to meet the IO summary listed, The controllers shall be minimum 32 bit single microprocessor based standalone working on TCP/IP on LAN with integral web browser, calender fundtion complete with day, month, week, year etc, real time clock & 1 second scan time. DDC working on 230V AC are preferred. The DDC's shall be capable of peer to peer communication without help of communication controller / router / system interface controller / PC. with locable mounting cabinets duly powder coated connector strip, internal wiring and space to house controller & relays, connector strip step down transformer, MCB, internal wiring. (Contractor shall confirm his I/O provision w.r.t requirement on basis of data point) on AHRAE approved Bacnet protocol only
DDC Panel for Chiller Plant Room AS ABOVE
DDC Panel for Other Equipment at terrace and metering AS ABOVE
DDC Panel for AHUs AS ABOVE
DDC Panel for Ventilation Fans AS ABOVE
Field Devices Supply, installation, testing, commissioning of necessary Input sensor transmitters/transducers comprising the following:
Immersion Temp Sensor for CHW line with brass thermowell. Measuring range: -30 to 110 Deg C, Accuracy: +/- 1.3 Deg C
Outside Temp & Humidity Sensor with radiation shield. Measuring Range: Temp:-30 to 50 Deg C & RH 0-100%, Accuracy: +/- 1 Degc +/- 3%
Flow meter (Flow range to be provided)
Differential pressure switch Water Trigger Range:150-1000mbar with 1A (resistive) @ 240V AC contact rating
Duct type temperature & RH sensor. Meauring range: 0 -40 DegC & 0-100% RH, Accuracy: +/-0.5 DegC & 3%
Air Quality sensor to measure VOC contamination in air with 0-10 VDC output.
CO2 sensor Duct mount type Measuring range: 0 to 2000 ppm
Differential pressure switch for filters (0-400Pa range)
Water DP Sensor
Level Switches (Hi/Low)
Water Flow Switch with operating range of 15Kg/sq.cm
Conduiting , Wiring and cabling Supply, installation, testing and commissioning of following cables:
2 Core 1.0 Sqmm, unarmoured ATC conductor multistranded, Unshielded cable.
2 Core 1.5 Sqmm, unarmoured ATC conductor multistranded, shielded cable.
3 Core 1.5 Sqmm, unarmoured ATC conductor multistranded, cable for Powering DDC , Actuators.
Cat-6 networking cable
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
20mm dia AS ABOVE
25mm dia AS ABOVE
STP (CIVIL)
EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
CONCRETE WORK
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shttering - All work up to plinth level 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
REINFORCED CEMENT CONCRETE
Centering & shuttering including strutting, propping etc. and removal of form work for:
Foundations, footings, bases of columns etc. for mass concrete.
Suspended floors, roofs, landings, balconies and access platform.
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars. FE 500 D
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discre
All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum
All works above plinth level upto floor V level "Concrete of M25 grade with minimum cement content of 330 kg /cum"
BRICK WORK
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
STEEL WORK
Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc.as required. In gratings, frames, guard bar, ladders, railings, brackets, gates & similar works.
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angles 40x40x6 mm for diagonal braces
FLOORING
52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nomina size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
FINISHING
12 mm cement plaster finished with a floating coat of neat cement - 1:4 (1 cement: 4 fine sand)
6 mm cement plaster of mix : - 1:3 (1 cement : 3 fine sand)
Neat cement punning.
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers
15 mm cement plaster on the rough side of single or half brick wall of mix : - 1:4 (1 cement: 4 fine sand)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : - New work (two or more coats) over and including water thinnable priming coat with cement primer
Finishing walls with Acrylic Smooth exterior paint of required shade : - New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
MISCELLANEOUS WORK
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS : 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Supplying and fixing C.I. cover without frame for manholes : 455x610 mm rectangular C.I. cover (light duty) the weight of the cover to be not less than 23 kg
Providing and fixing soil, waste and vent pipes : Centrifugally cast (spun) iron S&S pipe as per IS:3989 100 mm dia.
LIFTS
Lift -22 Persons Capacity (Kgs) : 22 Persons ( 1496 kg ) SPEED (MPS : 1.75 Mps RISE (M) : 25 M Stops : 6 Stops with (all opening on the same side) Controller type : ACD3 - MRL DRIVE : VF Regenerative ( Closed Loop) Power Supply : 415 Volts, + 5%, 3 phase , 50 Cycles Operation : Full collective operation Car Group : One Car (simplex) Machine : PM Gearless (Located in staft on to of guide rails ) Traction Media : Flat Coated /Grooved steel Belt
CAR FINISH * Rear Side panels = Powder Coated Paint Finish * Side mid panels = Powder Coated Paint Finish * Side Corner Panels = Powder Coated Paint Finish * Front Panels = Powder Coated Paint Finish False Ceiling Type : CD - 41 False Ceiling Finish : Powder Coated Paint Finish Ventillation : Cross Flow fan Hand Rails : Powder Coated Paint Finish Handrails on rear Car Panels Flooring : Vinyl Tiles Car door finish : Powder Coated Paint Finish Landing Door Finish : Powder Coated Paint Finish PIT Depth : 1450 Overhead : 4400
Hoistway Dimensions Required (W x D - mm) : 2580 mm W x 2400 mm D Car Dimensions (W x D x H - 1750x2000x 2300 mm ) : / asper drawing CAR & Hoistway Door : Telescopic 2 Speed Door Door Opening ( W x H - mm) : 1200 mm W x 2000 mm H Door Operator ; DC Door Operator COP : Buttons in Stainless steel # 4 ( Hairline) CAR Position Indicator : Dot matrix (LED) Scrolling Display Hall Fixtures : PAN Type Fixture Hall Fixture Face Plate : Stainless Steel # 4 ( Hairline) Standard Fiatures : Anti-nuisance Car Call Protection, Independent Service (for Duplex only), Overload Device, Nudging, Emergency Firemen’s Service, Emergency Car Light Unit, Infrared Curtain Door Protection, Door Time Protection, Emergency Alarm Button, Extra Door Time of Lobby & Parking, Door Open/Close Button, Manual Rescue Operation, Belt Inspection Drive, Auto Fan Cut Off Option Included : * Automatic Rescue Operation
Lift -19/20 Persons Capacity (Kgs) : 19 /20 Persons ( 1292 kg ) SPEED (MPS : 1.75 Mps RISE (M) : 25 M Stops : 6 Stops with (all opening on the same side) Controller type : ACD3 - MRL DRIVE : VF Regenerative ( Closed Loop) Power Supply : 415 Volts, + 5%, 3 phase , 50 Cycles Operation : Full collective operation Car Group : One Car (simplex) Machine : PM Gearless (Located in staft on to of guide rails ) Traction Media : Flat Coated /Grooved steel Belt
CAR FINISH * Rear Side panels = Powder Coated Paint Finish * Side mid panels = Powder Coated Paint Finish * Side Corner Panels = Powder Coated Paint Finish * Front Panels = Powder Coated Paint Finish False Ceiling Type : CD - 41 False Ceiling Finish : Powder Coated Paint Finish Ventillation : Cross Flow fan Hand Rails : Powder Coated Paint Finish Handrails on rear Car Panels Flooring : Vinyl Tiles Car door finish : Powder Coated Paint Finish Landing Door Finish : Powder Coated Paint Finish PIT Depth : 1450 Overhead : 4400
Hoistway Dimensions Required (W x D - mm) : 2330 mm W x 2400 mm D Car Dimensions (W x D x H - 1450x2000x 2300 mm ) : / asper drawing CAR & Hoistway Door : Telescopic 2 Speed Door Door Opening ( W x H - mm) : 1200 mm W x 2000 mm H Door Operator ; DC Door Operator COP : Buttons in Stainless steel # 4 ( Hairline) CAR Position Indicator : Dot matrix (LED) Scrolling Display Hall Fixtures : PAN Type Fixture Hall Fixture Face Plate : Stainless Steel # 4 ( Hairline) Standard Fiatures : Anti-nuisance Car Call Protection, Independent Service (for Duplex only), Overload Device, Nudging, Emergency Firemen’s Service, Emergency Car Light Unit, Infrared Curtain Door Protection, Door Time Protection, Emergency Alarm Button, Extra Door Time of Lobby & Parking, Door Open/Close Button, Manual Rescue Operation, Belt Inspection Drive, Auto Fan Cut Off Option Included : * Automatic Rescue Operation
GOODS Lift - Capacity (Kgs) : 2440 kg and above SPEED (MPS : 0.40 Mps RISE (M) : 25 M Stops : 6 Stops with (all opening on the same side) Controller type : ACD3 - MRL DRIVE : VF Regenerative ( Closed Loop) Power Supply : 415 Volts, + 5%, 3 phase , 50 Cycles Operation : Full collective operation Car Group : One Car (simplex) Machine : PM Gearless (Located in staft on to of guide rails ) Traction Media : Flat Coated steel /Grooved Belt
CAR FINISH * Rear Side panels = Powder Coated Paint Finish * Side mid panels = Powder Coated Paint Finish * Side Corner Panels = Powder Coated Paint Finish * Front Panels = Powder Coated Paint Finish False Ceiling Type : CD - 41 False Ceiling Finish : Powder Coated Paint Finish Ventillation : Cross Flow fan Hand Rails : Powder Coated Paint Finish Handrails on rear Car Panels Flooring : Vinyl Tiles Car door finish : Powder Coated Paint Finish Landing Door Finish : Powder Coated Paint Finish PIT Depth : 1600
Overhead : 4800 Hoistway Dimensions Required (W x D - mm) : 2900 mm W x 3050 mm D Car Dimensions (W x D - 2000x2500 mm ) : / asper drawing CAR & Hoistway Door : Telescopic 2 Speed Door Door Opening ( W x H - mm) : 1200 mm W x 2000 mm H Door Operator ; DC Door Operator COP : Buttons in Stainless steel # 4 ( Hairline) CAR Position Indicator : Dot matrix (LED) Scrolling Display Hall Fixtures : PAN Type Fixture Hall Fixture Face Plate : Stainless Steel # 4 ( Hairline) Standard Fiatures : Anti-nuisance Car Call Protection, Independent Service (for Duplex only), Overload Device, Nudging, Emergency Firemen’s Service, Emergency Car Light Unit, Infrared Curtain Door Protection, Door Time Protection, Emergency Alarm Button, Extra Door Time of Lobby & Parking, Door Open/Close Button, Manual Rescue Operation, Belt Inspection Drive, Auto Fan Cut Off Option Included : * Automatic Rescue Operation
HORTICULTURE AND PLANTATION
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil
Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.
Ordinary rock
Hard rock (blasting prohibited)
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and stacking of good earth at site including royalty and carriage up to 5 km (earth measured in stacks will be reduced by 20% for payment).
Supplying and stacking sludge at site including royalty and carriage up to 5 km (sludge measured in stacks will be reduced by 8% for payment).
Supplying and stacking at site dump manure from approved source, including carriage up to 1 km (manure measured in stacks will be reduced by 8% for payment) :
Screened through sieve of I.S. designation 16 mm
Fine dressing of the ground.
Spreading of sludge, dump manure and / or good earth in required thickness as per direction of Officer-in-charge (Cost of sludge, dump manure and / or good earth to be paid separately).
Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge..
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) : - Holes 90 cm dia, and 90 cm deep
Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately).
Complete maintaince of the entire garden features in the garden area i.e. lawn trees, shurbs, hedges, flower beds, creepers etc. including hoeing, pruning replacements of plants, gap filling, watering, mowing of lawn, clipping of hedges, removal of garden waste, applying inseticide, pesticide & fertilizer(whenever required) top dressing of lawn with good earth and manure and maintenace of other garden related works for 12 months (1 year) as directed by officer-in-charge. (Note:-Good earth, maure, fertilizer, insecticide, pesticide etc & all T&P articles & stock material will be provided bt the department.) - Open spaces(as per yard stick 1Mali =3.00Acre).
Providing and Displaying plants Budded Rose (H.T. variety) 3 to 4 healthy branch 30 cm and above ht. well developed with one and above flower plant in 20 cm Earthen Pot, as per direction of the officer-in-charge.
Providing and Displaying plants Creeper Rose variety 3 to 4 healthy branch 60 cm and above ht. well developed with one and above flowers in 25 cm Earthen Pot, as per direction of the officer-in-charge.
Providing and Displaying plants Standard Rose (H.T. variety) 3 to 4 healthy branch 90 cm and above ht. well developed with one and above flowers in 25 cm Earthen Pot, as per direction of the officer-in-charge.
Timber and Flowering tree
Supply and stacking of Grevillea robusta (Silver Oak) plant of height 150- 165 cm. in big poly bags of size 25 cm as per direction of the officer-incharge
Supply and stacking of Polyalthia longifolia (Ashok) plant of height 150- 165 cm. in earthen pots of size 25 cm as per direction of the officer-incharge.
Supply and stacking of Acacia auriculiformis (Amaltas) plant of ht 150-165 cm in bag size of 25 cm as per direction of the officer-in-charge.
Supply and stacking of Millingtonia hortensis plant of height 150-165 cm.in big poly bag of size 25 cm as per direction of the officer-in-charge.
Supply and stacking of Spathodea campanulata plant of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
Supply and stacking of Delonix regia (Gulmohar) plant of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge
FURNITURE
Providing & fixing Reception Table as per photograph. Size: 4350(W) x 900(D) x 750/1100(Ht)mm. Reception worksurface top 25mm thick in prelaminated particle board at 750mm ht. Side Gable end 25mm thick in pre laminated particle board. Reception table modesty 25mm thick in prelaminated particle board of 1100mm ht, working Table top have wiremanager hole cut for passing the wires. Ledge top (white) of 200mm (d) and below the ledge top 200mm (d), 25mm thick in pre laminated particle board supprted with studs. Front white panel in 25mm pre laminated particle board All exposed edges sealed with 2mm thick pvc edge banding tape. Table have metal cable tray duly powder coated below the table top run for the wires without switch & socket plates. Metal wire riser for carrying wires. Providing and placing Metal Pedestal with an overall size 400(w) x 450(d) x 600(ht)mm with 2nos of drawers & 1 filling Drawer. Pedestal shall be movable with castors. Pedestal facia have recessed type in built handle with locking arrangement. Metal pedestal having facia in 1mm and rest of the body and inner drawer are made of 0.8mm thick CRCA high yield strength CRCA sheet of grade ‘D’ confirming to IS: 513 duly powder Coated with 40-50 microns after 7 tank pre-treatment process flow of approved colour & shade etc. The Pedestal Drawers are mounted on metallic roller slides on both sides.
Providing & Placing Side Storage as per photograph. The Storage top shall be made out of 25mm thick Pre-Laminated Particle Board of approved shade, design and colour. All exposed edges are sealed with 2mm thick pvc edge banding tape pressed at 200 degree C with hot melt glue on special machines. The understructure shall be made out of 18mm thick Pre-Laminated Particle Board. The storage is having openable shutter with locking arrangement. The storage is having 18mm thk. PLPB shelves. Size: 1500(w) x 450(D) x 750(Ht)mm.confirming to ANSI/BIFMA standards
Supplying and placing ergonomically designed, comfortable & aesthetically appealing Medium back chair. The seat shall be made of 15mm thick hot pressed commercial plywood upholstered with high resilience moulded polyurethane foam having density 48kg/m³ with foam net tapestry. The seat shall be upholstered with fabric tapestry 0.8mm thick and 300 GSM and the back shall be made of polypropylene net cover upholstered with breathable mesh tapestry. The backrest shall be made with contoured lumbar support and maintain the natural curvature of the spine. The chair shall be supplied with PU adjustable arm. The chair shall have synchro tilt 360 degree revolving mechanism with upright position locking. The Pedestal should have five legged injection moulded black nylon having pitch circle dia. 650 mm fitted with 5 nos. twin wheel castors which shall be made of injection moulded in 30% glass filled nylon having self lubricating property for friction free movement, confirming to ANSI/BIFMA standards .
Supplying and placing sofa that shall be constructed from natural hard wood and commercial plywood having inner frame. The thickness of the wood should allow for the heavy tension webbing. The sofa shall have spring attached and also be padded separately. The frame shall be padded with high resilience polyurethane foam having density 40Kg/m³ in seat and 32Kg/m³ in back. There shall be cushion arm provided padded with high resilience polyurethane foam having density 32Kg/m³. The complete structure shall be upholstered with leatherite tapestry 0.8±0.1 mm thick and 535 GSM. The understructure shall consist of SS 202 grade leg having Dia. 38mm. There shall be shoe provided at the bottom to avoid scratches on the floor.
THREE SEATER SOFA (SIZE- 1950 X 750X 750HT)(-+10)
TWO SEATER SOFA (SIZE- 1350 X 750X 750HT)(-+10)
Providing & Supplying in position of Table as per photograph. Center Table top made out of glass. Table understructure shall be made SS brushed frame. Table have a small buffer to avoiding the scracing on the floor.
Size:- 600(L) x 450(D) x 400(ht)
Size:-1200(L) x 600(D) x 400(ht)
L-SHAPE WORKSTATION Size: 1500 X 1500 (W) X 600 (D) X 750/1050 (HT) WorkTop - Table top made up of 25mm thick prelaminated partical board with 2mm thick pvc edge banding tape. Understructure of 50 x 50mm droit Legs duly MS powder coated on both sides with connecting beam. Wire Management - Metal Flipper of 400 x 120mm size without switch socket is fixed on worktop with metal cable tray below the table top for Electrical points and wire riser for carrying wires. 32mm thick Screen half white board/ half pinup board 300ht. Providing and placing Metal Pedestal with an overall size 400(w) x 450(d) x 600(ht) mm with 2nos of drawers & 1 filling Drawer. Pedestal shall be movable with castors. Pedestal facia have recessed type in built handle with locking arrangement. Metal pedestal having facia in 1mm and rest of the body and inner drawer are made of 0.8mm thick CRCA high yield strength CRCA sheet of grade ‘D’ confirming to IS: 513 duly powder Coated with 40-50 microns after 7 tank pre-treatment process flow of approved colour & shade etc. The Pedestal Drawers are mounted on metallic roller slides on both sides. confirming to ANSI/BIFMA standards
Supplying and placing ergonomically designed, comfortable & aesthetically appealing Medium back chair. The seat shall be made of 15mm thick hot pressed commercial plywood upholstered with high resilience moulded polyurethane foam having density 48kg/m³ with foam net tapestry. The seat shall be upholstered with fabric tapestry 0.8mm thick and 300 GSM and the back shall be made of polypropylene net cover upholstered with breathable mesh tapestry. The backrest shall be made with contoured lumbar support and maintain the natural curvature of the spine. The chair shall be supplied with PU adjustable arm. The chair shall have synchro tilt 360 degree revolving mechanism with upright position locking. The Pedestal should have five legged injection moulded black nylon having pitch circle dia. 650 mm fitted with 5 nos. twin wheel castors which shall be made of injection moulded in 30% glass filled nylon having self lubricating property for friction free movement, confirming to ANSI/BIFMA standards .
Providing & Placing Storage as per photograph. The Storage top shall be made out of 25mm thick Pre-Laminated Particle Board of approved shade, design and colour. All exposed edges are sealed with 2mm thick pvc edge banding tape pressed at 200 degree C with hot melt glue on special machines. The understructure shall be made out of 18mm thick Pre-Laminated Particle Board. The storage is having openable shutter with locking arrangement. The storage is having 18mm thk PLPB shelves.
Size: 1200(W) x 450(D) x 750(Ht)mm.
Size: 6600(W) x 450(D) x 1200(Ht)mm.
Size: 3000(W) x 450(D) x 1200(Ht)mm.
WorkTop - Table top made up of 25mm thick pre laminated partical board with 2mm thick pvc edge banding tape. Understructure of 50 x 50mm Droit Legs duly MS powder coated on both sides with connecting beam. Modesty 18mm thick PLPB 600ht with edge banding tape. Wire Management - Flipper of 400 x 120 mm without switch socket on worktop with metal cable tray below Table top for Electrical points and wire riser for carrying wires. Side storage top made of 25mm thick plpb. Side storage understructure made of 18mm pre laminted partical board. Side storage shall have a design of openable shutter. Side Storage shall have proper locking arrangement. Back storage top made of 25mm thick plpb. Back storage understructure made of 18mm prelaminted partical board. Back storage shall have a design of openable shutter. Storage shall have proper locking arrangement. confirming to ANSI/BIFMA standards
Table Size: 1800W x 700D x 750Ht mm, Side Size: 1000W x 400D x 750Ht mm, Back Storage Size: 2550W x 450D x 750Ht mm.
Table Size: 1800W x 700D x 750Ht mm, Side Size: 1000W x 400D x 750Ht mm, Back Storage Size: 2200W x 450D x 750Ht mm.
Table Size: 1800W x 700D x 750Ht mm, Side Size: 1000W x 400D x 750Ht mm, Back Storage Size: 3000W x 450D x 750Ht mm.
Table Size: 1500W x 600D x 750Ht mm, Side Size: 900W x 400D x 750Ht mm, Back Storage Size: 1800W x 450D x 750Ht mm.
Table Size: 1800W x 700D x 750Ht mm, Side Size: 900W x 400D x 750Ht mm, Back Storage Size: 2700W x 450D x 750Ht mm.
Table Size: 1200W x 600D x 750Ht mm, Side Size: 900W x 400D x 750Ht mm, Back Storage Size: 2000W x 450D x 750Ht mm.
Table Size: 1800W x 700D x 750Ht mm, Side Size: 1000W x 400D x 750Ht mm
Table Size: 1800W x 700D x 750Ht mm, Side Size: 1000W x 400D x 750Ht mm, Back Storage Size: 3900W x 450D x 750Ht mm.
Supplying and placing ergonomically designed, comfortable & aesthetically appealing High back chair. The seat shall be made of 15mm thick hot pressed commercial plywood upholstered with high resilience moulded polyurethane foam having density 48kg/m³ with foam net tapestry. The seat shall be upholstered with fabric tapestry 0.8mm thick and 300 GSM and the back shall be made of polypropylene net cover upholstered with breathable mesh tapestry. The backrest shall be made with contoured lumbar support and maintain the natural curvature of the spine. The chair shall be supplied with PU adjustable arm. The chair shall have Synchro tilt 360 degree revolving mechanism with upright position locking. The Pedestal should have five legged injection moulded black nylon having pitch circle dia. 650mm fitted with 5nos. twin wheel castors which shall be made of injection moulded in 30% glass filled nylon having self lubricating property for friction free movement, confirming to ANSI/BIFMA standards.
Supplying and placing ergonomically designed, comfortable & aesthetically appealing Medium back chair. The seat shall be made of 15mm thick hot pressed commercial plywood upholstered with high resilience moulded polyurethane foam having density 48kg/m³ with foam net tapestry. The seat shall be upholstered with fabric tapestry 0.8mm thick and 300 GSM and the back shall be made of polypropylene net cover upholstered with breathable mesh tapestry. The backrest shall be made with contoured lumbar support and maintain the natural curvature of the spine. The chair shall be supplied with PU adjustable arm. The chair shall have synchro tilt 360 degree revolving mechanism with upright position locking. The Pedestal should have five legged injection moulded black nylon having pitch circle dia. 650mm fitted with 5nos. twin wheel castors which shall be made of injection moulded in 30% glass filled nylon having self lubricating property for friction free movement, confirming to ANSI/BIFMA standards.
ATTENDANT BED * Frame work made of rectangular/ square MS tube. * 5 cm foam padded top covered with rexine * Legs fitted with PVC Stumps * Overall Size: 180 L x 60 W x 46H cms. * Finish: Exoxy Powder coated.
Providing & Placing Storage as per photograph. The Storage top shall be made out of 25mm thick Pre-Laminated Particle Board of approved shade, design and colour. All exposed edges are sealed with 2mm thick pvc edge banding tape pressed at 200 degree C with hot melt glue on special machines. The understructure shall be made out of 18mm thick Pre-Laminated Particle Board. The storage is having openable shutter with locking arrangement. The storage is having 18mm thk. PLPB shelves. Size: 1800(w) x 450(D) x 750(Ht)mm.
Supplying and placing sofa as per photograph. The Sofa shall be constructed from natural hard wood and commercial plywood having inner frame. The thickness of the wood should allow for the heavy tension webbing. The sofa shall have spring attached and also be padded separately. The frame shall be padded with high resilience polyurethane foam having density 48Kg/m³ in seat and having density 32Kg/m³ in back. There shall be cushion arm provided padded with high resilience polyurethane foam having density 32Kg/m³. The complete structure shall be fully upholstered with Leathrite / Fabric tapestry. The understructure shall have metal. There shall be shoe provided at the bottom to avoid scratches on the floor.
THREE SEATER SOFA (SIZE- 1950 X 750 X 750HT)(-+10)
ONE SEATER SOFA (SIZE- 1350 X 750 X 750HT)(-+10)
Providing & Supplying in position of Table as per photograph. Center Table top made out of glass. Table understructure shall be made SS brushed frame. Table have a small buffer to avoiding the scracing on the floor.
Size:- 600(L) x 450(D) x 400(ht)
Size:-1200(L) x 600(D) x 400(ht)
WorkTop - Table top made up of 36mm thick pre laminated partical board with 2mm thick pvc edge banding tape. Understructure of 50 x 50mm Droit Legs duly MS powder coated on both sides with connecting beam. Wire Management - Flipper of 400 x 120mm without switch socket on worktop with metal cable tray below Table top for Electrical points and wire riser for carrying wires. Size: 7200W x 1500D x 750Ht mm
Providing & fixing table as per photograph. Size 3600 W x 1200D x 750mm height. Table Top shall be made out of 25mm thick Pre laminated particle Board of approved shade, design and colour. All exposed edges are sealed with the 2mm thick pvc edge banding tape and all unexposed edges sealed with 0.6mm edge banding tape pressed at 200o C with hot melt glue on special machines. The Metal Flipper is fixed on worktop of size 400 x 120mm, without switch & socket with metal cable tray below Table top for Electrical points with metal wire riser for carrying wires. The gable end shall be made of 25mm thick prelaminated particle board. The Modesty shall be made of 18mm thick prelaminated particle board. All exposed edges are sealed with the 2mm thick pvc edge banding tape and all unexposed edges sealed with 0.6mm edge banding tape pressed at 200o C with hot melt glue on special machines.
Supplying and placing ergonomically designed, comfortable & aesthetically appealing High back chair. The seat shall be made of 15mm thick hot pressed plywood upholstered with high resilience polyurethane foam having density 48kg/m³ with black leatherite tapestry 0.7mm thick and 535 GSM and the back shall be supported by MS CRCA metal frame upholstered with black leatherite tapestry 0.7mm thick and 535 GSM with contoured lumbar support which helps to provide full back support and maintain the natural curvature of the spine. The armrest shall be used MS chrome plated completely joint with seat and back. The chair shall have centre tilt 360 degree revolving mechanism with upright position locking and tilt tension adjustment. The Pedestal shall be made up of MS CRCA chrome plated having pitch circle Dia 650mm fitted with 5nos. 50mm twin wheel castors which shall be made of injection moulded black nylon 30% glass filled having self-lubricating property for friction free movement, confirming to ANSI/BIFMA standards .
Supplying and placing ergonomically designed, comfortable & aesthetically appealing Medium back chair. The seat shall be made of 15mm thick hot pressed plywood upholstered with high resilience polyurethane foam having density 48kg/m³ with black leatherite tapestry 0.7mm thick and 535 GSM and the back shall be supported by MS CRCA metal frame upholstered with black leatherite tapestry 0.7mm thick and 535 GSM with contoured lumbar support which helps to provide full back support and maintain the natural curvature of the spine. The armrest shall be used MS chrome plated completely joint with seat and back. The chair shall have swivel tilt 360 degree revolving mechanism with upright position locking and tilt tension adjustment. The Pedestal shall be made up of MS CRCA chrome plated having pitch circle Dia 650 mm fitted with 5 nos. 50mm twin wheel castors which shall be made of injection moulded black nylon 30% glass filled having self-lubricating property for friction free movement, confirming to ANSI/BIFMA standards.
Providing & Placing Storage as per photograph. The Storage top shall be made out of 25mm thick Pre-Laminated Particle Board of approved shade, design and colour. All exposed edges are sealed with 2mm thick pvc edge banding tape pressed at 200 degree C with hot melt glue on special machines. The understructure shall be made out of 18mm thick Pre-Laminated Particle Board. The storage is having openable shutter with locking arrangement.The storage is having 18mm thk. PLPB shelves. Size: 4950(w) x 450(D) x 750(Ht)mm.
Size: 5000(w) x 450(D) x 1200(Ht)mm.
WORKSTATION WorkTop - Table top made up of 25mm thick pre laminated partical board with 2mm thick pvc edge banding tape. Understructure of 50 x 50mm droit Legs duly MS powder coated on both sides with connecting beam. Wire Management - wire manager hole on worktop with metal cable tray below the table top for Electrical points and wire riser for carrying wires. 32mm thick Screen half white board/ half pinup board 300ht. Providing and placing Metal Pedestal with an overall size 400 (w) x 450 (d) x 600(ht) mm with 2nos of drawers & 1 filling Drawer. Pedestal shall be movable with castors. Pedestal facia have recessed type in built handle with locking arrangement. Metal pedestal having facia in 1mm and rest of the body and inner drawer are made of 0.8mm thick CRCA high yield strength CRCA sheet of grade ‘D’ confirming to IS: 513 duly powder Coated with 40-50 microns after 7 tank pre-treatment process flow of approved colour & shade etc. The Pedestal Drawers are mounted on metallic roller slides on both sides. confirming to ANSI/BIFMA standards
Size:1200(W) X 600(D) X 750/1050(HT)
Supplying and placing ergonomically designed, comfortable & aesthetically appealing Medium back chair. The seat shall be made of 15mm thick hot pressed commercial plywood upholstered with high resilience moulded polyurethane foam having density 48kg/m³ with foam net tapestry. The seat shall be upholstered with fabric tapestry 0.8mm thick and 300 GSM and the back shall be made of polypropylene net cover upholstered with breathable mesh tapestry. The backrest shall be made with contoured lumbar support and maintain the natural curvature of the spine. The chair shall be supplied with PU adjustable arm. The chair shall have synchro tilt 360 degree revolving mechanism with upright position locking. The Pedestal should have five legged injection moulded black nylon having pitch circle dia. 650mm fitted with 5nos. twin wheel castors which shall be made of injection moulded in 30% glass filled nylon having self lubricating property for friction free movement, confirming to ANSI/BIFMA standards .
Providing & Placing Storage as per photograph. The Storage top shall be made out of 25mm thick Pre-Laminated Particle Board of approved shade, design and colour. All exposed edges are sealed with 2mm thick pvc edge banding tape pressed at 200 degree C with hot melt glue on special machines. The understructure shall be made out of 18mm thick Pre-Laminated Particle Board. The storage is having openable shutter with locking arrangement. The storage is having 18mm thk. PLPB shelves.
Size: 3000(w) x 450(D) x 750(Ht)mm.
Size: 3150(w) x 450(D) x 1200(Ht)mm.
Size: 2100(w) x 450(D) x 750(Ht)mm.
Providing & fixing Main Table along with the side unit and drawer as per photograph. The Table Top shall be made out of 36mm thick prelaminated particle board, all exposed edges sealed with 2mm thick pvc edge banded tape. The table have one side Drawer unit with metal studs support for the top, Metal Flipper of 400 x 120mm without switch socket with metal cable tray below Table top for Electrical points. Drawer unit made of 18mm thick prelaminated particle board, Drawer have 3 equal drawer, all exposed edges sealed with 2mm thick pvc edge banded tape, Table have other side support with Side storage. Side stoarge have openable shutters along with Drawer unit & open space. The table Modesty shall be made out of 18mm thick pre laminated particle board. The Side Storage top shall be made out of 18mm thick pre laminated particle board and understructure shall be made out of 18mm pre lamionated partical board. Table Drawer & Side Storage rest on the metal beam all exposed edges sealed with 2mm thick pvc edge banded tape. The back Storage top shall be made out of 25mm thick Pre-Laminated Particle Board of approved shade, design and colour. All exposed edges are sealed with 2mm thick pvc edge banding tape pressed at 200 degree C with hot melt glue on special machines. The understructure shall be made out of 18mm thick Pre-Laminated Particle Board. The storage is having openable shutter with locking arrangement. The storage is having 18mm thk. PLPB shelves. Table Size: 2250(w) x 1050(D) x 750(Ht)mm, Side unit size- 1650(w) x 450(D) x 650(Ht)mm, Back Storage size- 4000(w) x 450(D) x 750(Ht)mm.
Supplying and placing ergonomically designed, comfortable & aesthetically appealing High back chair. The seat shall be made of 15mm thick hot pressed commercial plywood upholstered with high resilience moulded polyurethane foam having density 48kg/m³. The seat shall be upholstered with fabric tapestry 0.8mm thick and 300 GSM and the back shall be made of polypropylene net cover upholstered with breathable mesh tapestry. The backrest shall be made with contoured lumbar support and maintain the natural curvature of the spine. The chair shall be supplied with PU adjustable arm. The chair shall have Synchro tilt with multi locking 360 degree revolving mechanism with upright position locking with tilt adjustment. The Pedestal should have five legged injection moulded black nylon having pitch circle dia. 650 mm fitted with 5 nos. twin wheel castors which shall be made of injection moulded in 30% glass filled nylon filled having self lubricating property for friction free movement, confirming to ANSI/BIFMA .
Supplying and placing ergonomically designed, comfortable & aesthetically appealing Medium back chair. The seat shall be made of 15mm thick hot pressed commercial plywood upholstered with high resilience moulded polyurethane foam having density 48kg/m³. The seat shall be upholstered with fabric tapestry 0.8mm thick and 300 GSM and the back shall be made of polypropylene net cover upholstered with breathable mesh tapestry. The backrest shall be made with contoured lumbar support and maintain the natural curvature of the spine. The chair shall be supplied with PU adjustable arm. The chair shall have Synchro tilt with Mutli locking 360 degree revolving mechanism with upright position locking with tilt adjustment. The Pedestal should have five legged injection moulded black nylon having pitch circle dia. 650mm fitted with 5 nos. twin wheel castors which shall be made of injection moulded in 30% glass filled nylon filled having self lubricating property for friction free movement, confirming to ANSI/BIFMA standards.
Supplying and placing a sofa that shall be constructed from natural hard wood and commercial plywood having inner frame. The thickness of the wood should allow for the heavy tension webbing. The sofa shall have spring attached and also be padded separately. The frame shall be padded with high resilience polyurethane foam having density 48Kg/m³ in seat and having density 32Kg/m³ in back. There shall be cushion arm provided padded with high resilience polyurethane foam having density 32Kg/m³. The complete structure shall be fully upholstered with leatherite tapestry 0.7mm thick and 535 GSM. The under structure shall have wooden leg. There shall be shoe provided at the bottom to avoid scratches on the floor.
THREE SEATER SOFA (SIZE- 1950X 750X 750HT)(-+10)
TWO SEATER SOFA (SIZE- 1350X 750X 750HT)(-+10)
Supplying and Placing Table as per photograph. Table Size:- 1200(L) x 600(D) x 450(Ht). The Table top 25mm thick Pre laminated particle Board with decorative Laminate, All exposed edges Sealed with 2mm thick pvc edge banding tape laminate of approved shade, design and colour. Base in Chrome Finish.
Supplying and Placing Table as per photograph. Table Size:- 600(L) x 600(D) x 450(Ht) The Table top 25mm thick Pre laminated particle Board with decorative Laminate, All exposed edges Sealed with 2 mm thick pvc edge banding tape laminate of approved shade, design and colour. Base in Chrome Finish.
Providing & Placing Table. Size:- 1800(w) X 600(d) X 750(ht). The top shall be made out of 25mm thick Pre-Laminated Particle Board of approved shade, design and colour. All exposed edges are sealed with 2mm thick pvc edge banding tape pressed at 200 degree C with hot melt glue on special machines. The Gable end shall be made out of 18mm thick Pre-Laminated Particle Board. The Modesty shall be made out of 18mm thick Pre-Laminated Particle Board 600ht. Back Storage Size:- 1800(w) X 450(d) X 750(ht). The back Storage top shall be made out of 25mm thick Pre-Laminated Particle Board of approved shade, design and colour. All exposed edges are sealed with 2mm thick pvc edge banding tape pressed at 200 degree C with hot melt glue on special machines. The understructure shall be made out of 18mm thick Pre-Laminated Particle Board. The storage is having openable shutter with locking arrangement. The storage is having 18mm thk. PLPB shelves.
Supplying and placing ergonomically designed, comfortable & aesthetically appealing Medium back chair. The seat shall be made of 15mm thick hot pressed commercial plywood upholstered with high resilience moulded polyurethane foam having density 48kg/m³ with foam net tapestry. The seat shall be upholstered with fabric tapestry 0.8mm thick and 300 GSM and the back shall be made of polypropylene net cover upholstered with breathable mesh tapestry. The backrest shall be made with contoured lumbar support and maintain the natural curvature of the spine. The chair shall be supplied with PU adjustable arm. The chair shall have synchro tilt 360 degree revolving mechanism with upright position locking. The Pedestal should have five legged injection moulded black nylon having pitch circle dia. 650mm fitted with 5 nos. twin wheel castors which shall be made of injection moulded in 30% glass filled nylon having self lubricating property for friction free movement, confirming to ANSI/BIFMA standards .
WorkTop - Table top made up of 25mm thick pre laminated partical board with 2mm thick pvc edge banding tape. Understructure of 50 x 50mm Droit Legs duly MS powder coated on both sides with connecting beam. Modesty 18mm thick PLPB 600ht with edge banding tape. Size:- 750(L) x 500(D) x 750 (Ht)
Supplying & Placing Chair ergonomically designed for user comfort & shall have aesthetically appealing design. The seat shall be made of 12mm thick hot pressed plywood upholstered with high resilience polyurethane foam having density 48kg/m³ with fabric tapestry of 300 GSM and the back shall be made of polypropylene. The arm shall be provided MS chrome plated having Dia. 25.4mm with PU on top for comfort. The frame structure shall be four legged support type made up of chrome plate round pipe of Dia 20mm with 1.5mm thick. There shall be PPCP shoe provided at the base to avoid scratches on the floor.
WorkTop - Table top made up of 25mm thick pre laminated partical board with 2mm thick pvc edge banding tape. Understructure of 50 x 50mm Droit Legs duly MS powder coated on both sides with connecting beam. Modesty 18mm thick PLPB 600ht with edge banding tape. Size:- 1800(L) x 600(D) x 750 (Ht)
Supplying and placing ergonomically designed, comfortable & aesthetically appealing Medium back chair. The seat shall be made of 15mm thick hot pressed commercial plywood upholstered with high resilience moulded polyurethane foam having density 48kg/m³ with foam net tapestry. The seat shall be upholstered with fabric tapestry 0.8mm thick and 300 GSM and the back shall be made of polypropylene net cover upholstered with breathable mesh tapestry. The backrest shall be made with contoured lumbar support and maintain the natural curvature of the spine. The chair shall be supplied with PU adjustable arm. The chair shall have synchro tilt 360 degree revolving mechanism with upright position locking. The Pedestal should have five legged injection moulded black nylon having pitch circle dia. 650 mm fitted with 5 nos. twin wheel castors which shall be made of injection moulded in 30% glass filled nylon having self lubricating property for friction free movement, confirming to ANSI/BIFMA standards .
Providing & Placing Table as per photograph. Table Top shall be made out of 25mm thick, pre laminate particle board, laminate of approved shade, design and colour. The Gable end shall be made out of 18mm thick, prelaminated particle board, laminate of approved shade, design and colour. Modesty shall be made out of 18 mm thick, prelaminated particle board, laminate of approved shade, design and colour, Modesty 600mm HT. In Center box shall be made out of 18mm thick, pre laminate particle board, laminate of approved shade, design and colour. Size:- 2100(L) x 600(D) x 750(Ht).Partition height will be 1200mmx50/75mm inbetween any two students to ensure student reading privacy
Providing & Placing Round Table as per photograph. Table Top shall be made out of 25mm thick, pre laminate particle board, laminate of approved shade, design and colour. The Gable end shall be made out of 18mm thick, prelaminated particle board, laminate of approved shade, design and colour. Modesty shall be made out of 18 mm thick, prelaminated particle board, laminate of approved shade, design and colour, Modesty 600mm HT. In Center box shall be made out of 18mm thick, pre laminate particle board, laminate of approved shade, design and colour. Size:- 1200(Dia.) x 750(Ht)
Supplying & Placing Chair whose seat and back shall be made of 12mm thick hot pressed plywood upholstered with high resilience polyurethane foam having density 32kg/m³ with black leatherite tapestry 0.7mm thick and 535 GSM. The seat and back shall be fixed with metal frame. The frame structure shall be supported by four legs made up of MS CRCA chrome plated round pipe of size 20mm with 1.5Mm thick. There shall be PPCP shoe provided at the base to avoid scratches on the floor.
Providing & Placing Storage as per photograph. The Storage top shall be made out of 25mm thick Pre-Laminated Particle Board of approved shade, design and colour. All exposed edges are sealed with 2mm thick pvc edge banding tape pressed at 200 degree C with hot melt glue on special machines. The understructure shall be made out of 18 mm thick Pre-Laminated Particle Board. The storage is having openable shutter with locking arrangement. The storage is having 18mm thk. PLPB shelves.
Size: 4600(w) x 450(D) x 1200(Ht)mm. (LIBRARY)
Size: 23700(w) x 450(D) x 1200(Ht)mm. (LIBRARY)
Size: 5600(w) x 450(D) x 1200(Ht)mm. (LIBRARY)
Size: 14250(w) x 450(D) x 1200(Ht)mm.(LIBRARY)
Office Steel Almirah without locker : Providing and placing in position of Office Steel Almirah without locker of size 910(w) x 480(d) x 1980(ht)mm. Almirah carcass made of 0.8mm thikness high yield strength CRCA steel sheet of grade ‘D’ confirming to IS: 513. Almirah shall have 4 shelves making 5 compartments. Almirah is having door made of 1mm thick high yield strength CRCA steel sheet of grade ‘D’ confirming to IS: 513 with locking arrangement. Almirah shelves shall be made of CRCA steel sheet of 1mm thickness with stiffners below the shelfs for good Strength & support.The Almirah is having Mazak Handle with hidden rod & lock. The Almirah shall have metal legs. Almirah shall be powder coated of approved colour and shade with 40-50 microns with 7 tank pre-treatment process.
Supplying and placing 3 seater sofa that shall be constructed from natural hard wood and commercial plywood having inner frame. The thickness of the wood should allow for the heavy tension webbing. The sofa shall have spring attached and also be padded separately. The frame shall be padded with high resilience polyurethane foam having density 40Kg/m³ in seat and 32Kg/m³ in back. There shall be cushion arm provided padded with high resilience polyurethane foam having density 32Kg/m³. The complete structure shall be upholstered with leatherite tapestry 535 GSM. The understructure shall consist of SS 202 grade leg having Dia. 38mm. There shall be shoe provided at the bottom to avoid scratches on the floor. THREE SEATER SOFA (SIZE- 1950 X 750 X 750HT)(-+10)
THREE SEATER SOFA (SIZE- 1950 X 750 X 750HT)(-+10)
TWO SEATER SOFA (SIZE- 1350 X 750 X 750HT)(-+10)
Providing & Supplying in position of Table as per photograph. Center Table top made out of glass. Table understructure shall be made SS brushed frame. Table have a small buffer to avoiding the scracing on the floor.
Size:- 600(L) x 450(D) x 400(ht)
Size:-1200(L) x 600(D) x 400(ht)
Indutrial Locker with 12 door : Providing and placing a personal locker in perfectly upright and straight position. The overall size of the locker is 910(w) x 480(d) x 1980(ht)mm. The personal locker shall have 12 nos. of doors. It shall be (like top, side, back, door, shelf etc.) made of 0.8mm thickness high yield strength CRCA sheet of grade ‘D’ confirming to IS: 513. The main frame and base shall be semi welded and folded constructions which have intrinsic rigidity and high load carrying capacity. Uniformly distributed load capacity of each shelf shall be 40 Kg. The door shall be operated with aesthetically appealing snap fit ABS plastic handle and concealed crank hinge. Adjustable leveler shall be provided with metal insert to resist scratches on the floor and also level & support structure. The structure shall be supplied duly powder coated with 40-50 microns with 7 tank pre-treatment process. Locker shall have individual locking arrangement.
UG TANK
EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kind of Soil
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. Ordinary rock
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials. All kinds of soil
CONCRETE WORK
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shttering - All work up to plinth level
1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
REINFORCED CEMENT CONCRETE
Centering & shuttering including strutting, propping etc. and removal of form work for:
Foundations, footings, bases of columns etc. for mass concrete.
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platform.
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Columns, Pillars, Piers, Abutments, Posts and Struts
Edges of slabs and breaks in floors and walls Under 20 cm wide
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level or above plinth level. Thermo-Mechanically Treated bars.Fe 500D
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum
All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum
BRICK WORK
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.
WOOD WORK
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 100x10 mm
STEEL WORK
Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc.as required.
In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete
In gratings, frames, guard bar, ladders, railings, brackets, gates & similar works.
Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).
Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Extra for providing and fixing steel beading of size 10 x 10 x 1.6 mm (box type), approved shape and section with screws instead of glazing clips and metal sash putty, in steel doors, windows, ventilators and composite units.
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 10 x 140 mm
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece
FLOORING
Providing and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with (machine cut edges) of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). Red sand stone - 30mm thick gang saw cut stone
Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, welding etc. The frame work shall be fixed to the wall with the help of M.S. brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in brick wall with cement concrete block 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) of size 300x230x300 mm, including cost of necessary centring and shuttering and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to support stone cladding, the steel work will be given a priming coat of Zinc primer as approved by Engineerin- charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-in-charge for approval before execution). The frame work shall be fixed in true horizontal & vertical lines/planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall be paid).
Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required.
ROOFING
Providing and fixing on wall face unplasticised Rigid PVC rainwater pipes confirming to IS:13592 Type A including jointing with seal ring confirming to IS:5382 leaving 10 mm gap for thermal expansion.(I)single socketed pipes. 110 mm diameter
Providing and fixing on wall face unplasticised PVC moulded fitting acessories for unplasticised Rigid PVC rain water pipes confirming to IS-13592 type A including jointing with seal ring confirming to IS 5382 leaving 10mm gap for thermal expansion. Coupler 110 mm
Single tee with door AS ABOVE 110x110x110
Bend 87.5* AS ABOVE 110 mm bend
Shoes (plain) AS ABOVE 110 mm shoe
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
FINISHING
12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)
15 mm cement plaster on the rough side of single or half brick wall of mix: 1:6 (1 cement: 6 fine sand)
6mm cement plaster 1:3 (1 cement : 3 fine sand) on ceiling / R.C.C. Beams etc.
Neat cement punning.
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats
Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
MISCELLANEOUS WORK
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS : 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per stand ard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Supplying and fixing C.I. cover without frame for manholes : 455x610 mm rectangular C.I. cover (light duty) the weight of the cover to be not less than 23 kg
Providing and fixing soil, waste and vent pipes : 100 mm dia. Centrifugally cast (spun) iron S&S pipe as per IS:3989
WATER PROOFING
Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of : Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions. Using Roungh Kota stone
Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge : Using rough Kota stone
Providing and mixing integral crystalline admixture for waterproofing treatment to RCC structures like basement raft , retaining walls, re servior, sewage & water treatment plant , tunnels / subway and bridge deck etc. At the time of transporting of concrete into the drum of the ready- mix truck, using integral crystalline admixture @0.80% (minimum) to the weight of cement content per cubic metre of concrete ) of higher as recommended by the manufacture's specifictaion in renforced cement concrete at site of work. The material shall meet the requirments as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.
Providing and applying of swellable type water stop tape 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC stucture, such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the rataining primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all comlete as per specification and the direction of the engineer- in- chagre. The product performance shall carry guaranteed for 10 years against any leakage.
CAMPUS ROAD WORK
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm. depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth lead upto 50 metres.
Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density).
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25
Construction of dry lean cement concrete sub base over a prepared sub-grade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per specifications, cement content not to be less than 150 Kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, for all leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing etc. complete as per direction of Engineer-incharge.
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
"Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints ( 10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately ( minimum 40% flyash) Cement concrete manufactured in automatic batching plant (RMC plant) i/c transportation to site in transit mixer
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars.FE 500D
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). ( minimum 40% flyash)
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 75 mm diameter
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 300 mm dia. R.C.C. pipe
Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade 'A' sealing compound.
Supplying and stacking at site. Good earth
Providing and laying Grooming over finshed surface of CC road to make the surface rough as approved by architect and complete in all respect..
Providing grooves in CC road as per architecture drawing and design as approved by architect and complete in all respect..
HVAC WORK
All the rates quoted by the contractor shall be complete finished work including cost of all labour, material, scaffolding, finishing as required with tools, plants, lead, lift, taxes, tollage, octroi, royalties etc. except those specially excluded in the description of the individual items. All works shall be executed as per drawings, specification and instructions of Site incharge and shall include the supply and installation at site of all the equipment, ancillary materials as specified and all such items what-so-ever which may be required to fulfill the intent and purpose as laid down in the specification and/or the drawings. All materials shall be as per ISI specification and with IS certification marked wherever applicable. The material shall be duly approved by Site incharge before incorporation in the actual work NOTE a) All Equipment should be BMS Compatiable with BACnet / MODbus application b) All equipments foundation to be included in the quote C) All equipments should comply with ECBC(Latest) applicable Requirements along with BOQ requirements
Part-A : High Side Works-Air Conditioning
Chilling Units (Screw Type) with VFD 'Supply, Installation, Testing and Commissioning of AHRI Certified Air cooled Screw Water Chillers with VFD complete with Air cooled Copper - Aluminium condensers, Single/ multiple Compressors, Single/multi circuit Chiller, refrigerant R-134a, microprocessor based Control system, Electrical panel, mounting frame works, vibration isolators, integral refrigerant piping and wiring, all required accessories, automatic & safety controls, advanced microprocessor based control panel along with required hardware & software for integration with a 3rd party BMS (Open protocol). The condenser shall be mandatory coated with goldfin or epoxy or equivalent coating. ASME Stamped evaporator first charge of refrigerant and oil, incommer switchgear with terminations box suitable for terminations of XLPE AL armoured cables, earthing terminations etc. all mounted on a steel frame, foundation bolts nuts and accessores complete duly finished as per manufacturer standard as required & as per technical specifications with the following charactreistices complete as required :
WATER CIRCULATION PUMPS
Primary Chilled Water Pumps Supply, installation, testing and commissioning of Vertical Closed Coupled, Single stage, Single suction, Inline Centrifugal casing, top-pull-out design (i.e, the power head (motor, pump head, and impeller) can be removed for maintanence or service while the pump housing remains in the pipe work), primary chilled water pumps set complete with, Cast iron casing, Lead free bronze impeller, an internally-flushed mechanical seals and close coupled with stainless steel stub shaft arrangement with electric motor for re-circulation of chilled water circulation. The pump motor shall be TEFC squirrel cage induction motor having efficiency class IE3 (as per IEC 60034) with class 'F' insulation, 1500 RPM synchronous speed, operating on 415 V +/- 10%, 3 phase, 50 Hz AC supply. The motor shall be non- overloading type. Pumps will be with performance characteristics as given below. The pump and motor shall be mounted on a common base plate. All external and exposed cast iron parts of pumps should have an epoxy-based coating made in a cathodic electro-deposition (CED) process. Pump set shall be complete with thermal insulation same as chilled water pipes, aluminium cladding at suction and discharge, necessary anti vibration pads, MS base plate, and all other accessories complete as required.Pump material and operating conditions are given here unde(3Working + 1Standby) Flow: 1514 LPM Head: 12 Metre WC Motor HP : 7.5HP Pump Efficiency(Min): 80% or above 2 Nos. 150 mm dia. Dail-type pressure gauges. Lot- A mounting framework with anti-vibration pads. Lot- RCC/Cement concrete foundation for the pump unit. Primary chilled water pumps as described above. (2W+1S)
Secondary Pumps (Variable speed) Supply, installation, testing and commissioning of Vertical Closed Coupled, Single stage, Single suction, Inline Centrifugal casing, top-pull-out design (i.e, the power head (motor, pump head, and impeller) can be removed for maintanence or service while the pump housing remains in the pipe work), secondary chilled water pumps set complete with, Cast iron casing, Lead free bronze impeller, an internally-flushed mechanical seals and close coupled with stainless steel stub shaft arrangement with electric motor for re-circulation of chilled water circulation. The pump motor shall be TEFC squirrel cage induction motor having efficiency class IE3 (as per IEC 60034) with class 'F' insulation, 1500 RPM synchronous speed, operating on 415 V +/- 10%, 3 phase, 50 Hz AC supply. The motor shall be non- overloading type. Pumps will be with performance characteristics as given below. The pump and motor shall be mounted on a common base plate. All external and exposed cast iron parts of pumps should have an epoxy-based coating made in a cathodic electro-deposition (CED) process. Pump set shall be complete with thermal insulation same as chilled water pipes, aluminium cladding at suction and discharge, necessary anti vibration pads, MS base plate, and all other accessories complete as required.Pump material and operating conditions are given here under(3Working + 1Standby) Flow: 1514 LPM Head = 18 Metre WC Motor HP : 12HP Pump Efficiency(Min) : 80% or above 2 Nos. 150 mm dia. Dail type pressure gauges. Lot- Mounting frame work with anti vibration pads. Lot- RCC/Cement concrete foundation for the pump unit. Secondary chilled water pumps as described above (2W+1S)
Variable Speed Pumping System Supply, installation, testing and commissioning of VARIABLE SPEED PUMPING SYSTEM consisting of variable speed secondary chilled water pumps as per above with matching VFDs with pulse width modulation (PWM)type, one dedicated microprocessor based pump controller with parallel pumping software duly installed. Multi Pump Controller shall be listed by and bear the label of Underwriter’s Laboratory Inc (UL). Pump logic controller inbuilt with Variable frequency drives are not accepted. Logic controller should be external to the drives used in the system. Multi Pump Controller shall have programs to safeguard the system against the following conditions Pump flow surges, System Hunting, End of curve protection. Multi Pump Controller shall have program function to accept the pump curve data for optimizing the system performance in terms of energy consumption. Multi Pump Controller shall be capable of controlling up to six pumps in parallel. Automatic cascade control of pumps, automatic sequence change, friction loss compensation, pump status shall be there. Display screen shall be graphical type with minimum 320 pixels x 240 pixesl VGA display with backlight. The entire system along with chilled water pumps as described must be sourced from pump supplier only, to ensure unit responsibility. Should be compatible with Modbus / Bacnet.
Control panel (IP41) with VFD and Differential pressure transmittor as per above statement.
Civil work The HVAC vendor should include the cost of foundation requird for each chiller and other euipment in plant room. This include the civil work required after the approval of foundation drawings issued by OEM. The rubber pad should aslo be provided in the foundation in order to reduce the vibration.
Part 'B' : Low Side Works
Unitary Type Air Handling Units Ceiling suspended Supplying, installing, testing and commissioning of factory built Ceiling Suspended double skin type air handling units made of 43±2 mm thick panel with thermal break profile consisting of pre plasticized/ Pre-coated GI casing of 0.6 mm thickness outside layer and plane GI of 0.6 mm thick inside layer with polyurethene foam (PUF) insulation of density 40±2 kg/m3 factory injected between them by injection moulding machine, complete with blower section with blower forward curved belt deriven or direct driven plug fan with VFD for energy saving, having suitable external static pressure, aluminium finned copper tubes (tube thickness not less than 0.41mm), filter sections with 50 mm thick washable synthetic type Pre filters having efficiency 90% down to 10 micron with belt drive package with TEFC drive motor (IE-2) IP-55 Rating suitable for 415 ± 10% volts, 50 Hz, 3 phase, A.C supply TP isolator with MS enclosure box of required capacity, complete with drain connections with fittings, drain valve, test point for pressure guage & thermometer at the inlet and outlet of coil, stainless steel drain pan, necessary vibration isolation arrangement etc, complete as per tender specifications of following capacities:The Ahu casing should be third party certified confirming to EN 1886 2007 or Equivalent. ALL FLOOR
1200 CFM with 4 Rows Coil Cooling 2.4 Sqft. Coil Area, @ 30 mm Static WITH ALL VALVE WITH OUT 2WAY
1400 CFM with 4 Rows Coil Cooling with 2 pipe system, 2.8 Sqft. Coil Area, @ 40 mm Static WITH ALL VALVE WITH OUT 2WAY (1 pipe for CHW & 1 pipe for DX coil)
1500 CFM with 4 Rows Coil Cooling 3 Sqft. Coil Area, @ 35 mm Static WITH ALL VALVE WITH OUT 2WAY
1600 CFM with 4 Rows Coil Cooling 3.2 Sqft. Coil Area, @ 35 mm Static WITH ALL VALVE WITH OUT 2WAY
2000 CFM with 4 Rows Coil Cooling 4 Sqft. Coil Area, @ 35 mm Static
2200 CFM with 4 Rows Coil Cooling 4.4 Sqft. Coil Area, @ 35 mm Static
2400 CFM with 4 Rows Coil Cooling 4.8 Sqft. Coil Area, @ 35 mm Static
2500 CFM with 4 Rows Coil Cooling 5.0 Sqft. Coil Area, @ 35 mm Static
2800 CFM with 4 Rows Coil Cooling 5.6 Sqft. Coil Area, @ 40 mm Static
3200 CFM with 4 Rows Coil Cooling 6.4 Sqft. Coil Area, @ 40 mm Static
3200 CFM with 4 Rows Coil Cooling with 2 pipe system, 6.4 Sqft. Coil Area, @ 50 mm Static (1 pipe for CHW & 1 pipe for DX coil)
3500 CFM with 4 Rows Coil Cooling 7.0 Sqft. Coil Area, @ 40 mm Static
4000 CFM with 4 Rows Coil Cooling 8.0 Sqft. Coil Area, @ 40 mm Static
4500 CFM with 4 Rows Coil Cooling 9.0 Sqft. Coil Area, @ 40 mm Static
5000 CFM with 4 Rows Coil Cooling 10.0 Sqft. Coil Area, @ 40 mm Static
5500 CFM with 4 Rows Coil Cooling 11.0 Sqft. Coil Area, @ 40 mm Static
Horizontal Type Air Handling Units Supplying, installing, testing and commissioning of factory built Floor mounted double skin type air handling units made of 43±2 mm thick panels with suitable thermal break profile consisting of pre plasticized/Pre-coated G.I casing made of thickness 0.8 mm outside layer and G.I sheet of thickness 0.8 mm inside layer with polyurethane foam (PUF) insulation of density 42 kg/m3 factory injected between them by injection moulding machine, complete with Direct Driven Backward Curved Aerofoil Plug Type Fans with aluminium finned copper tubes (tubes thickness not less than 0.5 mm),filter sections with 50 mm thick washable synthetic type pre filter having efficiency 90% down to 10 micron, , Direct Drive package with TEFC (EFF-1) with VFD operation at 415 ± 10% volts, 50 Hz, 3 phase, A.C supply, mixing box ,drain connections with drain valve, stainless steel drain pan, necessary vibration isolation arrangement etc. TP isolator with MS enclosure box should be Provided. etc, complete as per specifications of following capacities:
8000 CFM with 6 Rows Coil Cooling 16.0 sqft. Coil Area, 45 mm Static pressure.
Control Valves for AHUs Dynamic Balancing cum modulating Supply, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure independent/electronic pressure independent type dynamic balancing valve with integrated 2 way modualating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum.
Water flow rate 6.0-10 USGPM 32dia
Water flow rate 11.0-20 USGPM 40dia
Water flow rate 21.0-40.8 USGPM 50dia
Modulating Themostat
Fan Coil Units. Supply, installation, testing and commissioning of ceiling suspended Normal static type FCU's each complete with 3 row deep cooling coil of copper tubes aluminium fins construction, centrifugal fan, 3 speed motor, with factorty fitted complete valve station (it includes ball valve with Strainer, ball valve without strainer, 2 way motorized valve, gauges etc.) ,filters insulated drain pan which covers the valve station completely, coil piping connections, thermostat, condensate drain connection, complete as required complete with manual air vent valve, SP isolator with MS enclosure box should be Provided etc. as required as per specification & drawings with the following capacities:-
400 CFM (1.0 TR)
600 CFM (1.5 TR)
800 CFM (2.0 TR)
Split Units Hi Wall Split Units (UPS Room) Supplying, fixing, testing and commissioning of Hi Wall/CASSETTE type split air-conditioning unit suitable to operate from 230±10% volt, 50 Hz, 1 phase power supply, with air-cooled evaporator with coil, fan,drain pump, and fan motor, air-cooled condenser with hermetically sealed rotery / reciprocating compressor condenser coil, propeller fans controls, control panel, Including control wiring, necessary power cable, M.S. frame duly painted to locate Outdoor Unit etc. The Unit should be atleast 3 Star rated. The Refrigerant pipe size and gas quantity should suit to the cupper pipe length at actual.(total circuit including liquid & suction) with interconnecting cabling between indoor / outdoor units as per site incharge, 13 mm thick.
2.0 TR (HUB ROOM) (hi-wall)
2.0 TR (HOD ROOM) (cassette unit)
Supply, installation, testing & commissioning of split type outdoor condensing unit. The unit shall be compatable with HERMETICALLY SEALED SCROLL compressor with inverter technology and air cooled heat exchanger and complete in all respect as per specification and drawing. The refrigerant pipe of respective outdoor condensing unit with communication cable, DX expansion kit, TPN isolator, power cable, outdoor stand etc. the unit shall be with 2.8 EER value or as per the latest ECBC.
Refrigerant Piping
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete withfittings, with suitable adjustable ring type hanger supports, jointing/brazingin cluding accessories, insulated with XPLE Class-O tubular sleeves section of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete withfittings, with suitable adjustable ring type hanger supports, jointing/brazingin cluding accessories, insulated with XPLE Class-O tubular sleeves section of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete withfittings, with suitable adjustable ring type hanger supports, jointing/brazingin cluding accessories, insulated with XPLE Class-O tubular sleeves section of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete withfittings, with suitable adjustable ring type hanger supports, jointing/brazingin cluding accessories, insulated with XPLE Class-O tubular sleeves section of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 19.00 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete withfittings, with suitable adjustable ring type hanger supports, jointing/brazingin cluding accessories, insulated with XPLE Class-O tubular sleeves section of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 15.86 mm dia (OD) (Softdrawn) with tube thickness 1.2 mm with 19 mm thick insulation
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete withfittings, with suitable adjustable ring type hanger supports, jointing/brazingin cluding accessories, insulated with XPLE Class-O tubular sleeves section of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 12.70 mm dia (OD) (Softdrawn) with tube thickness 1.2 mm with 19 mm thick insulation
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete withfittings, with suitable adjustable ring type hanger supports, jointing/brazingin cluding accessories, insulated with XPLE Class-O tubular sleeves section of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 9.5 mm dia (OD) (Softdrawn) with tube thickness 1.2 mm with 19 mm thick insulation
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete withfittings, with suitable adjustable ring type hanger supports, jointing/brazingin cluding accessories, insulated with XPLE Class-O tubular sleeves section of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 6.4 mm dia (OD) (Softdrawn) with tube thickness 1.2 mm with 19 mm thick insulation
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 300 mm width X 50 mm depth X 1.6 mm thickness
UVGI (Ultra Violet Germicidal Irradiation) SYSTEM The Active Air Purification system should consist of Supply, Installation, Testing and commissioning of Bipolar Ionisation System. The Bipolar Ionisation System must be a combination of Tube Based Model and Needle Point Model (Needle Point should have Nitinol (nickel titanium) Needles) and Carbon Fibre Brush Model, System should produce positive and negative ions for creating a Bio Climate rich in ions and hence neutralising harmful pollutants including pathogens, Volatile Organic Compounds and Particulate Matter. The Carbon Brush self-balancing ionizer should be installed at the fan inlet of fan coil units, VRF cassettes, ductless splits , AHU and Ductable HVAC System. These ionizers should be self-contained in a potted ABS box with a moulded flange and mounting holes and is protected with an inline 500mAglass cartridge fuse. The Needle Point Ionizer should be automatic cleaning needlepoint ionizer producing positive and negative ions that neutralize harmful pollutants and odours in the occupied space. The Needle Point compact unit Should automatically remove dust and dirt build-up on the emitters eliminating the need for any maintenance. The Unit can be easily mounted at the fan inlet of any air handling system, including RTU's, ptacs, mini-splits, fan coil units and VRF systems. The Unit should accept 12-24 VAC/DC. The Tube Based Model should be a single-tube or double tube or 5 tube unit that can be installed in ductwork utilizing the pre-drilled flange and factory applied gasket. The installer makes a duct cut out and secures the unit with self-tapping sheet metal screws. The unit can also be installed inside an AHU, Treated Fresh Air unit, Heat Recovery Ventilation Unit, utilizing a contractor supplied mounting bracket. Power to the ionization unit should be interlocked with system fan operation. The power input fitting provides easy disconnection of the power supply for servicing the unit. A five position ion level control knob varies the ion output between 50% and 100%. The Life of Tube should be minimum 17600 working hours.
Product should have UL 867 and UL 2998 certification (for zero ozone emission). The OEM shall have Efficacy test report on COVID from any Internationally/Nationally recognised Laboratory The System should be capable of providing periodic Preventive maintenance for automated after sales support service in form of notification/alerts and user interaction through dashboard application. Supplier must have experience of more than 3 years of executing projects with the same technology products. and have done at least 3 multi-location projects (Private Or Government) Pan India and Minimum Value of each project must be at Least 50 Lac.
Following Certifications are mandatory to produce The Carbon Brush and Self Cleaning nickel titanium based Needle Point Bipolar Ionizer must be UL 2043 certified. · The Carbon Brush and Self Cleaning nickel titanium based Needle Point Bipolar Ionizer must have UL-2998 Certification for Safety against Zero Ozone Emission as per recommendation by ASHRAE. · The Carbon Brush and Self Cleaning nickel titanium based Needle Point Bipolar Ionizer and Tube Based Model Should be tested on UL or Intertek/ETL to prove conformance to UL 867 for electronic devices. Other Product Certifications required are ISO16000 , CSA C22.2# 187, and CARB.
Manufacturers shall provide Test report from Internationally/Nationally recognized Lab for proven efficacy on below pathogens with minimum kill rates for the following pathogens given the allotted time and in a space condition: a) SARS-CoV-2 (COVID-19) Human Strain b) MS2 Bacteriophage (Surrogates COVID-19) c) Omicron Variant of SARS-CoV-2 d) H1N1 e) Total Bacterial Count Reduction rate of more than 90% from NABL Accredited Lab f) Yeas & Mold/Total fungal count Reduction rate of more than 90% from NABL Accredited Lab
FOR 26 FCU (19 NO.S 400CFM,4 NO.S 600 CFM, 3 NO.S 800 CFM)
FOR AHU 8000 CFM
Electrically Charged Filter Air purification for ceiling suspended Ductable indoor units and AHU The air purification system should be suitable to reduce harmful pollutants like particulate matter (PMx), PM 2.5, allergens, pollen, smoke, bacteria, pathogens etc. based on below principle technology viz;Impingement, Polarisation and Agglomeration as a passive air It should be a slim structured unit specifically designed for integration in Return Air path of ceiling suspended indoor units, to centrally capture. It should be equivalent to Merv-14 or Higher efficiency for AHU and Ductable* Units with low pressure drop. It should have 3x working principles and it should be aluminium based or powder coated steel casing and should be self-contained. It should be a US patented technology with UL certified components. The units shall meet ANSI/ASHRAE 52.2 standards and have valid test report to verify filtration efficiency. The Basic Media of Electric Filter shall Carry Class 2 Fire Rating Listing by UL.The EAC filter/Electrostatic percipitator (ESP), which have Metal based collection plate shall not be accepted. The Supplier shall carry UL2998 certification or at least Acknowledgement letter from UL2998 for testing against Zero Ozone Emission. The system shall be integrated with the existing pre-section filter area of AHU. The test report for pressure drop need to be submitted for passive air purification and the same shall be demonstrated at site. Product sholud be make in india (NSIC)
Electronic filters should consist of an Internet of Things (IoT) based Smart Filtration option employing a 3-Tier Architecture. This architecture would serve to identify pressure drops across the filter, indicating when a replacement is necessary due to clogged filters. Furthermore, it should gauge levels of filter blockage, enabling scheduled preventive maintenance to ensure sustainability. To facilitate user interaction, a well-designed UI/UX experience in the form of a dashboard is essential, complete with appropriate color-coding. Additionally, the system should generate alerts and notifications via text messages or emails to signal instances of filter clogging or the need for filter replacement. To enhance compatibility, the system must support various communication protocols, including options such as WiFi, Bluetooth Low Energy, Modbus RS485, or LoRaWAN. *Subject to Available Static as per OEM Technical Data Sheet.
FOR AHU-8000 CFM AS ABOVE
FOR CSU 1200 CFM-2400 CFM AS ABOVE
FOR CSU 2500 CFM-4500 CFM AS ABOVE
FOR CSU 5000 CFM-5500 CFM AS ABOVE
Indoor Air Quality Monitoring System- Supply, Installation, Testing & commissioning of IAQ Monitor to remotely measure the levels of PM 2.5, VOCs, CO2, Temperature, Humidity on a real time basis. The IAQ Monitor shall be capable of getting connected with Wi-Fi. The Monitor should be capable of sending the indoor air quality information on display Screen/Mobile/Workstation as per Client's requirement. The Monitor should indicate the quality of air through changing the colours on the display screen as per the NAAQS standards and should meet the WELL building standards. The monitor should be a 3 tier architecture including sensor Hardware, secure cloud infrastructure, monitoring apps including dashboard, android/IOS. Quoted price shall be inclusive of all necessary arrangement as required to make the unit proper functional. The System should provide Soft Assistance in form of Notifications and Alerts for Periodic Preventive Maintenance.
Dot matrix HMI/USB LAN Wi Fi Port based display system for dislplaying the air quality. AS ABOVE
Central Air Cleaner (CAC) For Fresh Air Fan CAC unit for Fresh AIr Fan. The air purification system should be suitable to reduce harmful pollutants like particulate matter (PMx), PM 2.5, allergens, pollen, smoke, bacteria, pathogens etc. It should be specifically designed for integration in Return Air path of Frsh Air Fan, to centrally capture the polutants. It should be equivalent to Merv-14 or Higher efficiency with low pressure drop. It should have 3x working principles and it should be aluminium based or powder coated steel casing and should be self-contained. It should be a US patented technology with UL certified components. The units shall meet ANSI/ASHRAE 52.2 standards and have valid test report to verify filtration efficiency. Contactor shall carry out tests at site for measuring the PM levels in various rooms to tests the efficacy of the air purification system.
Fresh Air Fan of 4000 CFM AS ABOVE
AIR CURTAIN Supply,Installation, testing & commissioning of Air Curtain for isolation of Air conditioned area from air cooled area .The length of the aircurtain length should be 1.2m minimum.The outlet velocity should be between 9.6 to 11.6m/sec and minimum airvelocity at 3meter shall be 2.4 m/sec
Insulation Chilled Water Piping Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by ENIFIX 530 adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.(underground pipe coating in header plant room to Building as per specification and drawing)
250 MM (32 mm thick insulation)
200 MM (32 mm thick insulation)
150 MM (32 mm thick insulation)
125 MM (32 mm thick insulation)
100 MM (32 mm thick insulation)
80 MM (32 mm thick insulation)
65 MM (32 mm thick insulation)
50 MM (32 mm thick insulation)
40 MM (32 mm thick insulation)
32 MM (19 mm thick insulation)
25 MM (19 mm thick insulation)
20 MM (19 mm thick insulation)
Butterfly Valves Providing and fixing the following Butterfly Valves with body, seat, disc, liner, bearing, shaft, handle, gear assembly etc.
100 MM for floor taping
80 MM for floor taping
Motorized Butterfly Valves Providing and fixing the following motorized butterfly valves BUTTERFLY VALVE WITH ON/OFF TYPE MOTORIZED ACTUATOR Single phase 220V with limit switches, C I body & PN 16 pressure rating SS Disc & shaft of Feedback, BMS Compatible for chilled water circulation as specified duly insulatated of following sizes as per specification and drawings. Cost should include necessary control wire (minimum size 1.5 sq.mm) . The differential pressure function shall be a Flow Sensor, BMS Compatible with flow details and flow has to be measured and set by the OEM/supplier at the time of commissioning
Balancing Valves BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified.
100 MM FOR FLOOR
80 MM FOR FLOOR
Non-Return Valves Providing and fixingthe following Non-Return Valve with body, seat, disc, liner, bearing, shaft, handle, gear assembly etc. 150 MM
Suction Guide Providing and fixing of suction guide of following sizes in the inlet of chilled water pumps 150 MM
Y Strainer Providing and fixing of Y Strainer of following sizes in the inlet of air handling units, pumps,Chillers
Pipe Flexible Connection Providing and fixing of rubber flexible connection of on pump outlet complete as per specifications and drawings. 150 MM
Pressure Gauges Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
Thermometers Providing & fixing in position the mercury in glass industrial type thermometers.
Flow Switches Providing and fixing water flow switch on chilled water outlet complete as per specifications and drawings.
Automatic Air Vents Providing and fixing auto airvent purging valve complete as per specification and drawings.
SUB HEAD 'C' - AIR DISTRIBUTION WORKS
Ducting Supply, fabrication, installation, balancing and commissioning of factory fabricated GI sheet metal rectangular ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings of following gauges as per SMACNA standard:-
Thickness 24 G sheet
Thickness 22 Gsheet
Thickness 20 G sheet
Supply, fabrication, installation, balancing and commissioning of site fabricated GI sheet metal rectangular ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings of following gauges as per IS standard:-
Thickness 24 G sheet
Thickness 22 Gsheet
Thickness 20 G sheet
Pre-insulated Ducting (Air Conditioning) Supplying, fixing smart PIR Panels CFC & HCFC free , Embossed Aluminium Foil of 80 Micron on both the side, 20 mm thick Anti Fungal and Anti Microbial with Pin holes on both the sides. Thermal Conductivity = 0.019 W/mk of SMART Preinsulated Panels 20mm/30mm thick with both sides Embossed Aluminium foil of 80 - 80 Micron(Anti microbial, Anti fungal, Anti Dust & Anti Rust coating & UV protection STARBOND 30 -36 Coating) and close cell not less than 95% Rigid Cellular foam insulation of thickness as specified below and material shall be Class O as per BS 476 Part 6 & 7, with Density of 48kg/m3 and should have Thermal Conductivity 0.019 W/mK , Water absorption shall be not more than 0.03% as per EN 13403 standard with 2 hours Fire Rating STARCOAT CRC complying BS476 Part 6,7,20 & 24 as per CBRI for vertical and horizontal duct. The ductwork should be capable of handling pressures upto 2000 Pascals. The joint between the ducts shall be done by means of Polymer slide in type joint between the ducts with New Advanced Gasketed Bayonet(maufacture make) and shiplap joints with Tiger Clamp and Special Tape manufactured approved for ducts with sizes below 400mm only for zero leakages. Duct supports to be provided at regular intervals.ENIFIX 550 adhesive is recommended for Preinsulated Panel insulation.
20 mm Thickness (Internal Ducting)
Supply, installation, balancing and commissioning of SMART Preinsulated Panels 30mm thick with both sides Embossed Aluminium foil of 200 - 200 Micron(Anti microbial, Anti fungal, Anti Dust & Anti Rust coating & UV protection Coating - Starbond 30 -36 ) and close cell not less than 95% Rigid Cellular foam insulation of thickness as specified below and material shall be Class O as per BS 476 Part 6 & Part 7, with Density of 48kg/m3 and should have Thermal Conductivity 0.019 W/mK , Water absorption shall be not more than 0.03% as per EN 13403 standard with 2 hours Fire Rating Starcoat CRC coating complying BS476 Part 6,7,20 & 24 as per CBRI for vertical and horizontal duct. . The ductwork should be capable of handling pressures upto 2000 Pascals. The joint between the ducts shall be done by means of Polymer slide in type joint between the ducts with New Advanced Gasketed Bayonet(maufacture make) and shiplap joints with Tiger Clamp and Special Tape manufactured approved for ducts with sizes below 400mm only for zero leakages. Duct supports to be provided at regular intervals. ENIFIX 550 adhesive is recommended for Preinsulated Panel insulation.
30 mm Thickness (External Ducting)
Supply, installation, testing & commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications.
Supply, fixing and commissioning of powder coated extruded aluminum grilles / diffuser complete with nuts, bolts, screws etc. as per approved drawings and specfications.
Supply & fixing of powder coated extruded aluminum Supply Air Grilles with aluminium volume control dampers as per specfications.
Supply & fixing of powder coated extruded aluminum Return Air Grilles with louvers but without volume control dampers as per specfications.
Supply & fixing of powder coated extruded aluminum exhaust air diffuser of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removal core.
Supply & fixing of powder coated extruded aluminum supply air diffuser of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removal core.
Supply & fixing of powder coated extruded aluminum return air diffuser of powder coated aluminium without aluminium volume control dampers with anti smudge ring & removal core.
jet diffuser with volume control damper
Supply, installation, testing and commissioning of anodised aluminium Fresh / exhaust air louvers with bird screen, as per specifications and drawings.
Supply, installation, testing and commissioning of fire rated canavas cloth connection as per specifications and drawings.
Supply, installation, testing and commissioning of the NON RETURN/Back draft Damper rated canavas cloth connection as per specifications and drawings.
SOUND ATTENUATORS :- Suuply, installation, testing & commissioning of sound attenuators to reduce noise in the duct. It is to be madd of GI type rectangular with 150mm wide air gaps and 75mm thick side in accoustic performance and construction as per specification & drawings.
Supplying, installation, testing and commissioning of fire dampers, the blades and frame shall be min. 1.6 mm thick GI and factory fitted in a sleeve made out of 1.6 mm thick GI of min. 400 mm long, as & where required, of required sizes including control wiring. The damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal. CBRI tested and certified for 90 minute fire rating etc. complete as required and as per specifications. (Total assembly should be UL listed)
Fire damper
Actuator
Duct Insulation Closed cell, Fire retardant, self extinguishing type crossed linked polyethylene insulation density not less than 24 Kg/sqM, 'K' value not be less than 0.031 W/mK with adhesive ENIFIX 530 and adhesive tape etc. on ducts complete as per specification and drawings. 10 MM thick
Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m3, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound ENIFIX BA - 60 adhesive etc. complete as required and as per specifications.
25 MM thick (for indoor ducts)
Supplying, fixing acoustic lining on wall and ceiling of AHU rooms with 50mm thick, density 32 kg/cu.m resin bonded glass fiber insulation friction fixed in 610mm x 610 mm frame work made of 25X50X50X50X25 mm made out of 0.6mm thick GI sheet U shaped channel and covered with reinforced fiber glass tissue and finished with 0.80 mm perforated aluminium sheet, CPRX compound ENIFIX BA - 60 adhesive etc. complete as required and as per specifications.
Underdeck Insulation Providing and fixing of crossed linked polyethylene class "O" insulation 15 mm thick fire retardand, self extingushing type, density not less than 24 Kg/sqM, 'K' value not more than 0.028 Kcal/degC for underdeck insulation with recommended ENIFIX 530 adheisve for better adhesion.
Expansion tank
Supply, Installation, Testing of open type expansion tank of MS Construction made of 6 mm thick mild steel sheet duly insulated with 50mm thick T.F quality expended polystyrene of 24 kg/cum density with adhesive ENIFIX BA 60 and covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) and finally cement plastered over chicken wire netting of 24 gauge and complete with vent and outlets for system connection over flow and drain 40 mm dia. Make up connection with float valve drain valve and incoming line valves, vent connections, valves and fittings as required. (OPEN TANK) 500 LTRS
Drain Piping G. I. drain piping of 'B' Class complete with fittings, supports, valves of 6 mm thick closed cell elastomeric insulation as per specifications and drawings. Providng and fixing pipes with all necessary fittings, supports and insulation.
Part-"D" - Ventilation
Axial Flow Fans for Exhoust Air Supply, Installation, Testing and Commissioning of AMCA certified ceiling hung type Exhaust air Tube Axial flow fan having 20 mm WG Static Pressure of following capacity with MS casing and aluminium alloy impellers with aero-foil sections, blades, the impeller directly driven by TEFC induction motor suitable for 415 V ± 10 %,50 Hz, 3 Phase,1400 RPM of class 'H' insulation, TP isolator with MS enclosure box etc. complete as required and as per specifications . Fan and Motor should be VFD compatible & Class IE-03 Efficiency , Fan Should be CE certified ALL FLOOR Exhaust Air Fan
2500 CFM @ 25 mm wg
6000 CFM @ 25 mm wg
6500 CFM @ 25 mm wg
7000 CFM @ 25 mm wg
12000 CFM @ 25 mm wg
13000 CFM @ 25 mm wg
16000 CFM @ 25 mm wg
Axial Flow Fans for Fresh Air Supply, Installation, Testing and Commissioning of AMCA certified ceiling hung type Supply air Tube Axial flow fan having 20 mm WG Static Pressure of following capacity with MS casing and aluminium alloy impellers with aero-foil sections, blades, the impeller directly driven by TEFC induction motor suitable for 415 V ± 10 %, 50 Hz, 3 Phase, 1400 RPM of class 'F' insulation, TP isolator with MS enclosure box etc. complete as required and as per specifications .Motor should be VFD compatible & Class IE-03 Efficiency , Fan Should be CE certified
6000 CFM @ 25 mm wg
6500 CFM @ 25 mm wg
7000 CFM @ 25 mm wg
12000 CFM @ 25 mm wg
13000 CFM @ 25 mm wg
16000 CFM @ 25 mm wg
4000 CFM @ 15 mm wg FOR CORRIDOR
Inline Fans Supplying, installing, testing and commissioning of AMCA certified Inline Fans in 120GSM galvanized steel sheet construction complete as per technical specifications. The scope of supply includes all accessories including flanges, supports, Baffels, flexible canvass connections, vibration mountings, making coutout in the wall and finishing the same upto the satisfaction of site incharge, Powder coated MS stand/support work etc complete in all respects.F class of insulation shall be considered for the electrical motor.
400-500 CFM @ 15 mm wg
100-300 CFM @ 15 mm wg
Propeller Fan Supply, Installation, Testing & Commissioning of Propeller type exhaust air fans suitable for following capacities complete with electric motor suitable for operation at 230 V+ 10%,50 Hz, 1 phase AC supply ,graivty louvers of the following capacities. 225 MM Dia
PRESSURIZATION FANS Supply, Installation, Testing and Commissioning of Axial flow fan suitable for outdoor application of following capacity with powder coated M.S. casing and aluminium alloy impellers with high efficiency (IE-3) aero-foil sections, blades, the impeller directly driven by TEFC induction motor (motor should be of high efficiency, suitable for 3 Phase 50 Hz 415 V ± 10 %,1400 RPM of class 'F' insulation etc. complete as required and as per specifications (40 mm Static Pressure WC) (For Pressurization of lift lobby, lift well, stair). Isolator with MS enclosure box should be Provided.
9700 CFM for pressurization of Lift Lobby
10000CFM for pressurization of Lift Well
Part "E": Electrical Works
Main A.C. Panel-P1 Incomer 1 Nos. 630 Amps EDO ACB TP+NL incoming (drawout type) 1 No. 900 Amps aluminium conductor bus bar duly sleeved 1 No. electronic energy meter with CTs. 1 No. Ammeter with ASS & CTs. 1 No. voltmeter with VSS. 3 Nos. phase indicating lamps Outgoing 3 Nos. 300 Amps TP+NL MCCB with rotary Screw type operated handle outgoing for chillers.(1 stand by) 1 No. Ammeter with ASS & CTs. 2 Nos. ON/OFF indicating lights 3 Nos. 32 Amps MCB TP+NL outgoing for primary chilled water pumps with 5.5 KW motor (1 standby) 3 Nos. 40 Amps MCB TP+NL outgoing for secondary chilled water pumps with 9.0 KW motor (1 standby) 1 No. 63 Amps MCCB TP+NL outgoing for spare 3 Nos. automatic star delta starter for 5.5 KW motor of primary chilled water pumps (1 standby) All starter shall have following accessories : 1 No. overload relay 1 No. Ammeter with ASS & CTs. 1 No. single phase preventer VSP-2. 2 Nos. ON/OFF indicating lights 2 Nos. ON/OFF push buttons
Panel - 4 (GROUND TO THIRD FLOOR) OUTGOING (FAN) 1 Nos. 16 Amps MCB outgoing for 1.5 TO 2.2 KW motor 1 No. DOL Starter 1 No. single phase preventer VSP-2. 1 No. Voltmeter 1 No. ammeter 2 Nos indicating lights 2 Nos. Push buttons 3 Nos Phase indicating lights
Panel - 5 (GROUND TO THIRD FLOOR) OUTGOING (FAN) 1 Nos. 32 Amps MCB outgoing for 3.7 KW motor 1 No. DOL Starter 1 No. single phase preventer VSP-2. 1 No. Voltmeter 1 No. ammeter 2 Nos indicating lights 2 Nos. Push buttons 3 Nos Phase indicating lights
Panel -6 (AHUs) OUTGOING 1 No. 16 Amps MCB 10 KA for 0.37-2.2 KW motor 1 No. DOL Starter 1 No. single phase preventer VSP-2. 1 No. Voltmeter 1 No. ammeter 2 Nos indicating lights 2 Nos. Push buttons 3 Nos Phase indicating lights
Panel -7 (AHUs) OUTGOING 1 No. 16-32 Amps MCB 10 KA for 3.7-5.5 KW motor 1 No. DOL Starter 1 No. single phase preventer VSP-2. 1 No. Voltmeter 1 No. ammeter 2 Nos indicating lights 2 Nos. Push buttons 3 Nos Phase indicating lights
Weather Proof isolators for outside equipments. Supply, installation, testing and commissioning of out door weather proof switch box of continuous welded construction, fabricated out of 2 mm thick G.I. sheet complete with water tight gasket with front openable and lockable door including earthing, painting, glands, danger boards etc. suitable for mounting on wall with M.S. angle iron frame of size 40x40x6 mm consisting of relevant I.S. specifications and drawings. 80 Amps TP+NL Isolator for outside equipments.
Providing, fixing, and termination of PVC insulated armoured aluminium conductor cables from main panel boards to various equipments and from sub-panel to AHU/Blowers etc. through walls/ceiling with appropriate clamps and fixing arrangements, termination, glands cable tray etc. as per specifications and drawings.
Earthing
Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for earth connection etc. complete as required.
Providing and fixing 6 SWG dia GI wire on surgace or in recess for loop earthing alongwith the existing surface/ recessed conduit/ submain wiring/ cable as required.
Cable Tray Fabricating and installing perforated MS cable trays including horizontal and vertical bends, reducers, tees cross members and other accessories as required and duly suspended from the ceiling with M.S. suspenders and including painting etc. as required.
100 mm x 50 mm x 1.6 mm
300 mm x 62.5 mm x 1.6 mm
SUB HEAD 'F' - CHILLER PLANT MANAGER
Chiller Plant Optimizer/ Manager
Supply, Installation, testing and commissioning of Chiller plant optimizer unit shall have stand alone control algorithm with 10 inch graphical touch screen to control all chillers (Air Cooled 5nos)and ancillary equipment having function for automatic smooth start and stop the entire chiller plant without any ON/OFF hunting, Maintaining equal run time of chillers and ancillary equipments, automatic turning off the equipment when it is not needed, easily enable/disable equipment in program of maintenance time if required, data logging for the temperature, Pressure, flow, TR, Kw/TR etc., alarm logging for equipment failure, low temperature trip protection for condenser circuit, minimising the by pass flow with maintaining flow parameters, optimization of pumping energy of variable primary/secondary/condenser pumps. Best possible balance between compressor energy consumption and the energy required to reduce condensing pressure with changing outdoor condition, system must have Modbus connectivity to give the data to third party BMS. Required sensors/flow meter/water DPT/bypass valve/motorized isolation valve shall be in scope of CPM supplier
Plant Machinery as under: Air cooled Chiller 250TRx 5nos. Primary Pumps 5nos. Secondary variable Pumps 5nos. Workstation PC Pentium IV computer 3000 Mhz with 500 GB hard disk,17" TFT monitor, 104 windows key board, mouse,serial and parallel ports WITH 600 DPI colour ink jet printer. This must have software integration on Chillers with 3rd party interface avaiable on Bacnet with accessories like Transformer, MCB, internal wiring and Relays with bases complete as per specifications.
FIRE FIGHTING WORK
SUB HEAD - I - (WET RISER SYSTEM - PUMPING EQUIPMENTS)
Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads.
2280 lpm at 88 m Head
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment with Batteries, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads.
2280 lpm at 88 m Head
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads.
180 lpm at 88 m Head
Supplying, Fabricating, Installation, Testing and Commissioning Air Vessel of continuous welded construction with flanged discharge header in pump house fabricated out of 10 mm thick dished ends and 8 mm thick MS sheet, Air Release Valve, complete with drain arrangement with 25 mm dia gun metal wheel valve complete with all accessories etc. as required of the following sizesas approved by architect and complete in all respect..:
2 Meter high and 450 mm dia suitable to operate Jockey Pump, Main Fire Pump & Diesel Engine Driven Fire Pump. (Valve Make -Zoloto/Sant/Eqv.) (Paint Make:-Asian / Burger/ Eqv.)
Supplying and fixing air realease valve made of 25 mm dia on top and flanged connection to riser with required accessories, paintingwith synthetic enamel paint and after One coat of primer of approved shade as required. (MAKE - ZOLOTO/SANT)
SUB HEAD - II - (HYDRANTS & SPRINKLER SYSTEM)
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :
Single headed Stainless steel
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISi marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as reauired :
Single headed Stainless steel
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforminq to IS 636 (type-A) as required :
Stainless Steel (Grade 304)
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. - 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 - 20 mm nominal internal dia gun metal globe valve & nozzle - Drum and brackets for fixing the equipmets on wall. - Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe & Socket
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :
Stainless Steel (Grade 304)
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :
2 way-100 mm dia M.S. Pipe
4 way-150 mm dia M.S. Pipe
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories.
Pendent Sprinkler
Upright Sprinkler
Horizontal side wall sprinkler
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required.
100mm dia
150mm dia
Providing, fixing, testing & comrnissioninq of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required
150mm dia
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, support channel, stockbar of following sizes comolete as reauired.
Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required.
Providing and fixing weather proof lockable cabinet of size not less than 0.75 x 0.6 x 0.25 mtr made out of MS sheet 2mm thick having central opening and 6 mm thick glazed glass doors (Two nos.) suitably marked on the outside with the letters "FIRE HOSE" including necessary locking arrangement and shall be painted with one coat of primer and two coats of synthetic enamel paint of approved shade as required as per specificationsas approved by architect and complete in all respect.. (Make - Exflame)
SITC weather proof M.S cabinet size 2100 mm x 1200 mm x 600 mm Supplying, installation, testing and commissioning of weather proof M.S cabinet size 700 mm x 600 mm x 300mm deep fabricated from 1.6mm thick M.S. sheets and M.S angle 40mmx40mmx6mm complete with glass, locking arrangements to accommodate the followingas approved by architect and complete in all respect.
The cabinet shall be painted with one coat of primer and 2 coats of synthetic enamel paint of approved shade.
MS Fire Hose Cabinet (750 X 600 X 300)mm, Fabricated from 16 Gauge MS Sheet, 5mm Thick Glass , Double Door with Locking Arrangement , powder coated (Make- Exflame) Rates are only for hose box
SUB HEAD - III - (PIPING, VALVES AND ACCESSORIES)
SLTC of M.S. pipe on surface Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint after One coat of primer required shade complete as required :
25 mm dia
32 mm dia
40 mm dia
50 mm dia
65 mm dia
80 mm dia
100 mm dia
150 mm dia
200 mm dia (wall thickness 6.3 mm)
250 mm dia (wall thickness 6.3 mm)
Providing, laying, testing & commissioning of 'B' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint after One coat of primer of required shade complete as required :
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gasket conforming to IS 13095 of following sizes as required :
50 mm dia
65 mm dia
80 mm dia
100 mm dia
150 mm dia
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISi marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :
65 mm dia
80 mm dia
150 mm dia
200 mm dia
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :
65mm dia
100mm dia
150mm dia
Supply, Installation, Testing and Commissioning of 100 mm dia Bourden type, Stainless Steel dial type Pressure Gauge including brass isolation valve and siphon pipe having calibration of 0-16 Kg / cm2 .as approved by architect and complete in all respect.. (MAKE:H-GURU / EQV.)
Providing, Installation, Testing and Commissioning of Gun Metal / Bronze Ball Valves screwed ends of following sizes as required. (For sprinkler drain )as approved by architect and complete in all respect. (MAKE - ZOLOTO , SANT) 25 mm dia
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 150 mm dia
Supplying and fixing of Fire Man's axe with heavy insulated rubber as per standard conforming to IS 926as approved by architect and complete in all respect. (MAKE - ZOLOTO , SANT)
Providing & fixing double flanged Metallic expansion with M.S. fixed flanges (PN-1.6) joint (suitable for system test pressure) of standard length as per manufacturers specs including rubber gaskets, flanges, nuts, bolts and washers complete as required as per specificationsas approved by architect and complete in all respect. (Make :- Electroflex / Eqv.)
65 mm dia
80 mm dia
150 mm dia
200 mm dia
SUB HEAD - IV - (FIRE EXTINGUISHERS)
Supply, installation, testing and commissioning of ISI marked (IS:15683:2006) portable chemical fire extinguisher halon free, water (gas pressure) type capacity 9 litres with gun metal cap and nozzle and complete in all respects including initial fill and wall suspension brackets as required as per specificationsas approved by architect and complete in all respect.
Providing and fixing fire extinguisher of carbon dioxide type consisting of brand new high pressure steel cylinder bearing IS: 7285 mark and having the approval of controller of explosives Nagpur, wheel type valve bearing IS:3224 mark internal discharge tube, 1 meter long high pressure discharge hose, non conducting horn, suspension bracket, fully charged bearing IS: making fixed to wall as directed conforming IS : 15683:2006as approved by architect and complete in all respect.
4.5kg capacity cylinder
Fire Extinguisher, Mechanical Foam Type Capacity 45 ltr, ISI Marked , IS :16018 (Wheeled Type) (Make- Exflame)
Providing & fixing foot valve are installed in side of the pumps to avoid flow reversal from to the sump, in order to maintain pump priming.
150 mm dia(Kirlosker)
COMMON EFFLUENT TREATMENT PLANT
Supplying Installation And commissioning of Equipmqnts for Sewwerage Treatment Plant of 135 m3/day (85+50) . The main source of effluent is wastewater resulting from toilets, kitchens, pantries, water washroom and Factory, restrict to mentioned blow inlet Parameter. The scope of work includes detail design, drawing, erection, commissioning as per MBBR including tertiary treatment type Common Effluent Treatment Plant complete with necessary equipment, interconnecting piping network etc.
The Details of electromechanical equipments are as follows The CETP design based on the following parameters: Daily average flow: 135 M3/Day PH : 6.5 to 7.5 BOD : Up to 300 S. Solids : Up to 200 COD : Up to 400 Oil & Grease : 20 mg/l Sewage discharge standard after treatment :- PH : 6.5 to 7.5 BOD : Not more than 30 mg/l S. Solids : Not more than than 20 mg/l COD : Not more than 50 mg/l COD : Not more than 10 mg/l Parameters/specification
Bar Screen : Supplying, installing, testing & commissioning of 1 nos manual bar screen of particular size having provision for lifting arrangement etc. complete as required. Size : 600mm X 800mm MOC : MSEP Type : Manual operated coarse bar screen
Air Blower For Collection, MBBR , Sludge tank & Treated water tank Qty. (Nos.) : 3 (2 duty+1 Standby) Make : AKASH/EVEREST/USHA/Equivalent Capacity : 95 m3/hr Head (m) : 4 MWC Power : 3.7 kw
Fine Bubble air diffusers ( Retrieval type) for MBBR Tank Qty. (Nos.) : 1 Lot as required Type: Fine Bubble Diffuser Size : 90 mm OD x 1000 mm Length Make : SCI
Coarse Bubble air diffusers for Collection, Sludge & Treated water tank Qty. (Nos.) : 1 Lot as required Type: Coarse Bubble Diffuser Size : 80 mm Dia Make : SCI
MBBR Media Qty. (Nos.) : 1 Lot as required MOC: PP Surface area : 400m2/m3 Make : GFT/Cooldeck/Equiv
Tube Pack Media Qty. (Nos.) : 1 Lot as required Type : Square Tube Type MOC: PVC Make : GFT/Cooldeck/Equiv
Dosing System Dosing pump : 01 No. Make : 0-6 lph , E-Dose Dosing Tank: 01 No, 100 lit, 0.03 kw
Sand filter in FRP Quantity : 01 no. Type : Vertical Down flow Valve: Manual Operated Diameter: 30” Inch HOS: 72” Inch Filter Material: FRP Vessel Make: Pentair Frontal piping: In UPVC Valve: Multiport Accessories: Pebbles, Gravels and Graded Quartz Sand
Sand filter in FRP Quantity : 01 no. Type : Vertical Down flow Valve: Manual Operated Diameter: 30” Inch HOS: 72” Inch Filter Material: FRP Vessel Make: Pentair Frontal piping: In UPVC Valve: Multiport "Accessories: Pebbles, Gravels, Graded Quartz Sand and Carbon IV 550"
Sludge Pump Duty : To feed sludge to SHT Type : Horizontal , Self priming, Monoblock pump Qty: 2 nos. (1 duty + 1 Standby) Capacity: 1 m3 /hr Head: 10 m Power: 0.75 kw Make: Kirloskar
Interconnected piping ( within battery limits) Quantity : 1 Lot, As required Gravity piping : UPVC, Pressure piping: UPVC, sch 40,ASTM D178/ HDPE Make: Prince / Finolex/Astral. Fittings: UPVC solvent jointed Air Piping: MS Make: Tata/Jindal/Eqv.
Valves (Manual) Quantity : 1 Lot, As required Pump Discharge : Gate – CI , Screwed end – Make - Aarko "Discharge Non return: Wafer – M.S.body, M.S.disc, Nitrile - Make - Marck" "Bypass/ Tank Drain/Sludge drain: Gate – CI , Screwed/Flange end – Make - Aarko" Sampling valves/Filter pump valves: Ball valve –PVC /PP – Make – Parth/Prince
Electrical Control Panel Quantity : 01 no. Operation : Auto/Manual operation Type: Non – Compartmentalized
Electrical accessories & cabling Flexible –PVC copper cables : 01 Lot Make : Polycab
Instruments Level Switch : 01 Lot, MOC-PP, As required Pressure Gauge : 01 Lot, As required
COMMON EFFLUENT TREATMENT PLANT AS DESCRIBED ABOVE(SR NO 762 TO 780)
RAIN WATER HARVESTING PIT
EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. All kind of Soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil (from 1.5 mtr to 3.0 mtr)
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
CONCRETE WORK
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shttering - All work up to plinth level
1:4:8 (1 Cement : 4 coarse sand (zone-III) dervied from natural sources : 8 graded stone aggregate 40 mm nominal size) dervied from natural sources
BRICK WORK
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
Cement mortar 1:4 (1 cement : 4 coarse sand)
MISCELLANEOUS WORK
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata,preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer –in-charge, beyond 90 metre & upto 150 metre depth below ground level. All types of soil
300 mm dia
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc.all complete, for all depths, as per direction of Engineer –in-charge 100 mm nominal size dia
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 100 mm nominal size dia
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 100 mm dia
NON SCHEDULE WORK
Double layer of Geo textile Non Woven (400 GSM):- To avoid invasion of soil, provide stability to the tank, and improve quality of water within the tank with tensile strength. (40 meter depth )
Supply of Rain Maxx Tank modules (Honeycomb design on each plate) made up of recycled polypropylene. These modules are made from combination of large and small plates. Each large plate should have atleast fourteen locking slots inorder to give stability to tank. These tank should have optimum connection & block stability using double lock stability.
Retas Makes - Supply and Installation of FRP Filter having SS 304 mesh bracket with dia 750mm and height 1000mm capable of removing particles from infllow water. FRP filter should be Griha certified under criterions 21& 18 and SVAGRIHA criterion 9. Certificate should be valid on date of installation
SIGNAGE ITEM
Building Tactile Door and/or Directional Braille Signages (Sizes between 225mmx150mm till 600mmx600mm) : Design, Supply of Acrylic multilingual Braille Tactile signages - like Building entrance , Door signages, Name plates, (raised domes) signboards of minimum size 9"X6" (225x150mm) to for doors, specific areas like toilets, water, etc. & directions (without maps or drawings) , designed as per the drawings issued and having 3+2mm thick blue Acrylic non glare base plate, and 0.5mm Thick Aluminium plate at backside, with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15mm raised 0.8mm above base plate and the equivalent word/s written in Hindi with Devnagri non glare acrylic letters of height 15mm raised 0.8mm above base plate. Signage to have a relevant symbol made of white cut out acrylic and raised by 0.8mm above base plate. Grade 1 Braille consisting of raised domes of 1.5 to 1.6mm dia. and spacing as per Braille standards given by GOI to be integral with the sign face and be raised 0.6 to 0.9mm above base plate.Each signboard to be fixed as per manufacturers specifications at the specified locations at a height of 1200mm from FFL and up to the satisfaction of the engineer in charge. ( These rates for all sizes specific to sizes from 22.5cmx15cm upto or below of 60cmx60cm maximum dimensions, in two colour scheme only)
Building Tactile Floor Directory, Evacualtion maps signage: Size from 24x18 Inches /600mmx450mm till max. 48x36 inches /1200mmX900mm) Design, supply, fabrication and fixing Acrylic multilingual Braille for Layouts / Maps, Floor directories, Evacuation plans maps, etc(raised domes) signboards of size 24"x 18" or above for directions, designed as per the drawings issued and having 3+3mm thick Blue Acrylic non glare base plate (Green in case of Fire evacaution plans) with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15mm raised 0.8mm above base plate and the equivalent word/s written in Hindi with Devnagri non glare acrylic letters of height 15mm raised 0.8mm above base plate. Signage to have a relevant symbol made of white cut out acrylic and raised by 0.8mm above base plate. Grade 1 Braille consisting of raised domes of 1.5 to 1.6mm dia. and spacing as per Braille standards given by GOI to be integral with the sign face and be raised 0.6 to 0.9mm above base plate.Each signboard to be fixed as per manufacturers specifications at the specified locations at a height of 1200mm from FFL and up to the satisfaction of the engineer in charge. ( These rates for all sizes under or upto 60cmx60cm maximum dimensions, in two colours scheme only)
Night Glowing Braille embedded Tactile signs: Building Tactile Door signs, Directional signs, Floor Directory, Evacualtion maps signage: Size from 24x18 Inches /600mmx450mm till max. 48x36 inches /1200mmX900mm) Design, supply, fabrication and fixing Acrylic multilingual Braille for Layouts / Maps, Floor directories, Evacuation plans maps, etc(raised domes) signboards of size 24"x 18" or above for directions, designed as per the drawings issued and having 3+3mm thick Blue Acrylic non glare base plate (Green in case of Fire evacaution plans) with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15mm raised 0.8mm above base plate and the equivalent word/s written in Hindi with Devnagri non glare acrylic letters of height 15mm raised 0.8mm above base plate. Signage to have a relevant symbol made of white cut out acrylic and raised by 0.8mm above base plate. Grade 1 Braille consisting of raised domes of 1.5 to 1.6mm dia. and spacing as per Braille standards given by GOI to be integral with the sign face and be raised 0.6 to 0.9mm above base plate.Each signboard to be fixed as per manufacturers specifications at the specified locations at a height of 1200mm from FFL and up to the satisfaction of the engineer in charge. ( These rates for all sizes under or upto 60cmx60cm maximum dimensions, in two colours scheme only)
Stainless steel Building tactile map , Floor directories , Door signs, Directional Signs, signage: Size (Sizes between 225mmx150mm till 600mmx600mm) Design, supply, fabrication and fixing SS 304 non glare matt finish 1.2mm thick sheet with braille rasters + backside acrylic multilingual Braille (raised domes) signboards of size 24"x 18" for directions, designed as per the drawings issued and having 1.2mm SS 304 sheet + 3mm thick acrylic base plate with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15mm raised 0.8mm above base plate and the equivalent word/s written in Hindi with Devnagri non glare acrylic letters of height 15mm raised 0.8mm above base plate. Signage to have a relevant symbol made of white cut out acrylic and raised by 0.8mm above base plate. Grade 1 Braille consisting of raised domes of 1.5 to 1.6mm dia. and spacing as per Braille standards given by GOI to be integral with the sign face and be raised 0.6 to 0.9mm above base plate.Each signboard to be fixed as per manufacturers specifications at the specified locations at a height of 1200mm from FFL and up to the satisfaction of the engineer in charge. ( These rates for all sizes under or upto 90cmx60cm maximum dimensions, in various colours as per layout and feasbilties as per ADA norms)
Providing of PU Tactile Tiles Brand " Prosafe" in standard tile size of 300x300x2.5mm for "Warning tiles & Directional tiles", with square edge for tight joints and minimum gaps, made from TPU from Covestro India (Former Bayers India), Yellow colour (RAL 1026), with properitory double sided self adhesive tape, suitable for Indoor high friction, with sufficient contrast colour as per ADA norms (ISO 23599:2012 complaint) and to be used togeter as warning tiles 20-25% ratio with Directional tiles 75-80% approx , for the visually impaired persons, on the pedestrian pathway as per manufacturers design / specification and as per harmonised guidelines of MOUD Govt. of India.
Providing and fixing Acrylic LED Letter on the Building itself as per the Elevation & drawings provided by Architect in charge
GRIHA
The contractor is responsible for overall management with GRIHA authorities, GRIHA Consultant, Design Architect and PMC for successful minimum GRIHA Three (03) Star certification of project. CDAC will only pay for the statutory fees for registrations of the project and other statutory requirements under GRIHA Certification process after submission of challans . Contractor is responsible for arranging all necessary documentations with revisions, drawings, arranging and coordinating stay, tour , site visits and site audits of GRIHA officials for successful certification of the project. CDAC will not pay any incidental expenditure in this regard.
Shubham EPC Private Limited
S K Integrated Consultants
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid