| Sl No | Description | Qty | Unit | PRIDE CONSTRUCTIONS L1 | shanmathi constructions private limited L2 |
|---|---|---|---|---|---|
| 1.00 | Earth work excavation and desposting on banks with initial lead of 10m and initial lift of 2m in hard stiff clay, stiff black cotton soil, hard red earth, shales, murram, gravel, stony earth and earth mixed with small size boulders et., As per SS 20B excluding hard rock requiring blasting inclusive of shoring shuttering, baling ojut water where ever necessary and including refilling consolidation etc., complete in all respects complying with relevent standard specifications and as directed by departmental officers. | 1,738.6 | Cum | 240 ₹4.2 L | 250 ₹4.3 L |
| 2.00 | Earth work open excavation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification. | 161 | Cum | 110 ₹17,710 | 112 ₹18,032 |
| 3.00 | Providing Pre-constructional anti- termite treatment and creating a chemical barrier to the building by injecting chemical emulsion of required concentrations raft slab and beam, under Cellular raft slab, around the footings, column pits, trenches, pits, wall trenches, back fill, plinth filling, junction of wall and floor, side walls of foundation, external perimeter of building,surrounding of pipes expansion joints, etc. as per IS specification and as per the instructions of chemical manufacturer and all as directed.The treatment shall be carried out strictly in accordance with the technical specification and conforming to IS 6313 (PART-2) or equivalent BS specification. | 2,430 | Sqm | 135 ₹3.3 L | 136 ₹3.3 L |
| 4.00 | Supplying and Filling with M - sand in foundation and others sub structures for 100mm thick and well watered, rammed and consolidated by power compacter. The rate includes the cost of M sand, compacting with mechanical compactors, labour charges for leveling, loading & Unloading and Transportation charges etc., complete and as per the standard specification. | 328.4 | Sqm | 1,800 ₹5.9 L | 1,818 ₹6.0 L |
| 5.00 | Plain Cement Concrete 1 : 5 :10 ( one part of cement, five parts of sand and ten parts of hard broken stone ) using 40 mm gauge hand broken hard broken granite stone jelly complying with standard specifications in foundations and basement. | 328 | Cum | 5,400 ₹17.7 L | 5,454 ₹17.9 L |
| 6.00 | Supplying and Filling Gravel in foundation and basement in layers of not more than 15cm.thick well rammed watered and compacted -1m3 etc., complete complying with standard specification. | 1,725 | Cum | 320 ₹5.5 L | 323 ₹5.6 L |
| 7.00 | Refilling the approved good quality earth in plinths, area development etc. wherever specified in layers of not exceeding 200 mm thick., with available earth at site. | 882.2 | Cum | 40 ₹35,288 | 40 ₹35,288 |
| 8.00 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, Sill slabs etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner, vertical stiffener, side support and Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid). | 1,011 | Sqm | 740 ₹7.5 L | 747 ₹7.6 L |
| 9.00 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc. using mild steel sheets of size 1200cm x 60cm and 10 BG stiffened with welded mild steel angles of size 40mm x 40mm x 5 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner, Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals. MS Channel Section (ISMC 100) shall be provided as a vertical support @1.20m C/C and with Lateral support of Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) & steel pipes of 20mm dia @ required level/spacing etc. complete complying with standard specifcation and as directed by the departmental officers. (Payment for centering shall be given after the concrete is laid) | 232 | sqm | 580 ₹1.3 L | 586 ₹1.4 L |
| 10.00 | Supplying and erecting steel centering including necessary supports For plane surfaces such as rectangular or square RCC columns etc. which require only nominal strutting using mild steel sheets made of 10 gauge thick welded with MS angle size 40mm x 40mm x 5 mm and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick).etc..complete in all floors complying with standard specifcation. Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid). | 1,322.26 | sqm | 640 ₹8.5 L | 647 ₹8.6 L |
Tender Value
₹9.5 Cr
EMD Value
₹4.9 L
Closing Date
3 Mar 2026, 3:00 pmClosed
Joint Commissioner/Executive Officer
Joint Commissioner/Executive Officer The Head Office Arulmigu Dhandayuthapani Swamy Temple, Adivaram Palani
Construction of Indoor Stadium For Palaniandavar Womens Arts And Culture College At Chinnakalaiyamuthur Dindigul District
2026_HRCE_655505_1
6/2025-2026/1
Open Tender
Civil Works - Buildings
365 days
Chinnakalaiyamuthur
Please refer Tender documents.
15 documents required · 15 mandatory
₹0
₹4.9 L
Joint Commissioner / Executive Officer
13 Mar 2026
12 Feb 2026
3 Mar 2026
12 Feb 2026
3 Mar 2026
23 Feb 2026
20 Feb 2026
Earth work excavation and desposting on banks with initial lead of 10m and initial lift of 2m in hard stiff clay, stiff black cotton soil, hard red earth, shales, murram, gravel, stony earth and earth mixed with small size boulders et., As per SS 20B excluding hard rock requiring blasting inclusive of shoring shuttering, baling ojut water where ever necessary and including refilling consolidation etc., complete in all respects complying with relevent standard specifications and as directed by departmental officers.
Earth work open excavation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification.
Providing Pre-constructional anti- termite treatment and creating a chemical barrier to the building by injecting chemical emulsion of required concentrations raft slab and beam, under Cellular raft slab, around the footings, column pits, trenches, pits, wall trenches, back fill, plinth filling, junction of wall and floor, side walls of foundation, external perimeter of building,surrounding of pipes expansion joints, etc. as per IS specification and as per the instructions of chemical manufacturer and all as directed.The treatment shall be carried out strictly in accordance with the technical specification and conforming to IS 6313 (PART-2) or equivalent BS specification.
Supplying and Filling with M - sand in foundation and others sub structures for 100mm thick and well watered, rammed and consolidated by power compacter. The rate includes the cost of M sand, compacting with mechanical compactors, labour charges for leveling, loading & Unloading and Transportation charges etc., complete and as per the standard specification.
Plain Cement Concrete 1 : 5 :10 ( one part of cement, five parts of sand and ten parts of hard broken stone ) using 40 mm gauge hand broken hard broken granite stone jelly complying with standard specifications in foundations and basement.
Supplying and Filling Gravel in foundation and basement in layers of not more than 15cm.thick well rammed watered and compacted -1m3 etc., complete complying with standard specification.
Refilling the approved good quality earth in plinths, area development etc. wherever specified in layers of not exceeding 200 mm thick., with available earth at site.
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, Sill slabs etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner, vertical stiffener, side support and Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid).
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc. using mild steel sheets of size 1200cm x 60cm and 10 BG stiffened with welded mild steel angles of size 40mm x 40mm x 5 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner, Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals. MS Channel Section (ISMC 100) shall be provided as a vertical support @1.20m C/C and with Lateral support of Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) & steel pipes of 20mm dia @ required level/spacing etc. complete complying with standard specifcation and as directed by the departmental officers. (Payment for centering shall be given after the concrete is laid)
Supplying and erecting steel centering including necessary supports For plane surfaces such as rectangular or square RCC columns etc. which require only nominal strutting using mild steel sheets made of 10 gauge thick welded with MS angle size 40mm x 40mm x 5 mm and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick).etc..complete in all floors complying with standard specifcation. Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid).
Supplying and erecting centering for plane surfaces such as RCC Floor Slab, Roof Slab, Loft, Landing Slabs, etc with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over steel adjustable span of size 2m x 2m (expandable upto 3.60m) and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) , etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid).
Providing and laying in position, standardised concrete Mix M-20 Grade in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials).
Foundation & Basement
Ground Floor
First Floor
Second Floor
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. (Contractor has to make his own arrangements for the supply of steel and binding wire)
Foundation & Basement
Ground Floor
First Floor
Terrace Floor
Brickwork in Cement Mortar 1:5(One cement and five sand) using II Class Ground Moulded Chamber Burnt Bricks of size 9" x 43/8" x 23/4" in foundation, basement and superstructure including curing etc. complete complying with standard specification.
Foundation & Basement:-
Brickwork in Cement Mortar 1:6(One cement and six sand) using II Class Ground Moulded Chamber Burnt Bricks of size 9" x 43/8" x 23/4" in foundation, basement and superstructure including curing etc. complete complying with standard specification.
Ground Floor:-
First Floor
Second Floor
Brick partition walls of 11.50cm thickness using best quality II Class Ground Moulded Chamber Burnt Bricks of size 9" x 41/2" x 3" in Cement Mortar 1:3 (One Cement and Three Sand) and both side plastering with CM 1:5 12mm thick using hoop iron reinforcement if found necessary including curing etc.complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately).
Ground floor
First Floor
Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers
Plastering with Cement Mortar 1:3 for Internal walls & External walls (One cement and Three Plastering sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
Plastering with Cement Mortar 1:5 for Internal walls & External walls (One cement and Five Plastering sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
STRUCTURAL STEEL WORKS: Designing, Providing and fixing in position Hot rolled structural steel Members / Sections consists of MS joists, channels, angles, purlins, pipes, hollow tubes, runners, insert plates, flats etc. at all levels. Surface preparation of all MS members by Sand blasting to SA 21/2 grade and painted with anti corrosive, low VOC PU paint (metallic finish) with compatible primer to a minimum film thickness of 75 microns and 2 coats of low VOC PU paint of Akzonoble make and total dry film thickness 225 microns. (Only Main structural supports related to Facade works if required any shall be considered and no base frame or support structure shall not be considered, which shall form part of the respective cladding and Glazing items). Refer Particular Specification for Mode of measurement for this item.
Providing and Fixing of polyurethane foam for Sloped roof as thermal insulation panels or Sandwich insulated panels with external 0.50mm total coated thickness pre painted Galvalume sheet with trapezoidal roofing profile having crest height of 38mm at every 333mm span , whereas internal 0.50mm total coated thickness pre painted galvanized iron sheet with micro ribbed profile and the insulation material will be chlorofluoro carbon and hydro chlorofluoro carbon free , high performance rigid polyurethane foam (PUF) conforming to IS 12436 having density not less than 40±2Kg/M3, Thermal conductivity (K-Value) 0.024 W/m.K measured at 10 degree C mean temperature along with necessary flashings such as L flashing, C flashing etc& accessories such as screws, fastners ,sealants etc for fixing the panel etc ., complete complying with standard specification.
Supplying and fixing G.I Sheet Gutters fir Collecting rain water from slopped position of G.I Sheet 0.8cm thick, 0.70cm wide with appropriate hanger including fixing in position and necessary cost of brackets, screws, nails etc., complete.
Dadooing walls with best approved quality, white / colour glazed tiles of size 450x300x8mm set in Cement Mortar 1:2 (One Cement and Two crushed stone sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers.
Flooring with Joint free double charged vitrified tiles of approved quality, colour and design joint free of size 600 x 600 x 8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (one cement three sand) 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40 kg/Sqm laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officers. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. (Including Skirting work)
Flooring with following Topflex sports flooring made with 4.5mm thk PVC sports flooring which has abrasion resistance, impact resistance, residual impression, fire resistance, light resistanct and sound isolation etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Flooring with following ceramic tiles of size Joint Free Rectified Ceramic tile of Size- 305 x 305 x 8mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three crushed stone Sand) base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Paving the floor with best approved quality Natural flammed finish granite for flooring/ steps & Landing of 18 / 20mm thick of with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three crushed stone sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification
Paving the floor with best approved quality fine polished Granite Stone Slabs of size 1200 x 600 of 18 / 20mm thick of Synthetic Grey, Paradise and similar varieties with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three crushed stone sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.
Supplying and laying hydraulic pressed monolithic natural grey colour cement concrete inter locking paver block of 83mm thick, in cement concrete 1:2:4 (one cement, two sand, four aggregate) using difference design and with stand for pressure of 150 - 200 kg/m2 over the existing sand cushion by using earth rambers and also vibratting the concrete blocks often laying using plate vibrators etc, complete as directed by the departmental officers.
Plain Cement Concrete 1:2:4 (one cement, two crushed stone sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.
Paving the Top of roof with Solar refelective ceramic tiles of approved quality and colour laid in Cement mortar bed in 1:3 (One cement and three crushed stone sand) 12mm thick and pointed with water resistant tile epoxy grout for joint, curing etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by the Executive Engineer before use on works)
Manufacturing supplying and fixing in position of teracotta jally 20x20x5cm thick approved quality and design in cement slurry including cost of materials labour curing lifting fixing in position etc, complete complying with standard specification and as directed by the departmental officers in all floors.
UPVC Window :Supplying and fixing UPVC (Un-Plasticized PolyvinylChloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm125GSMand 100% corrosion free, the profiles are multichambered sections with wall thick of 2mm. The EPDMrubber (black colour) covered with over all the edges offrame and shutter the shutter will be provided withEspag multi power point locks and also it operates ashandle. The corners and joints should be welded andcleaned. Radiations free pin headed plain or browncolour glass 4mm thick should be provided to theshutter and it should not allow leakage of water evenat most ranging storms and should have key lockableaction, security protective hinges, strong lockingsystems and as per size for arresting noise and energyloss. The connecting mechanism between sash andouter frame that enables opening of the window. Thewindow should be fixed to the wall with 100% packingwith screws and silicon packing all round the frames.The window should be got approved from the Executive Engineer before use on work.
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride)Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (blackcolour) covered with all over the edges of frame and shutter.The corners and joints should be welded and cleaned.Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
Solid PVC door shutters Toilet door using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC sheets. Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, Lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm, with suitable rebate for housing the shutter.
SLIDING DOOR :Providing & fixing sliding door using aluminium powder coated door frame and shutter sections with matt finish, party glazed with 6 mm plaing galss and partly panelled using 12 mm thick both side prelaminated particle board, fixed with fixed & sliding aluminium channels and fittings like 2 door handles, one concealed 4 lever lock, door stopper, 2 nos- 150mm long PC Aluminium tower bolts etc. all complete.
Door Frame: Supplying and fixing CRCA Pressed Steel Box Section 18 Gauge or 1.25mm thick for Door Frames including providing holes and fixing wooden blocks for fixing furniture and fittings etc. complete in all floors.
Supply & Fixing of Single Leaf Solid core Flush shutters with Teak ply on both side with teak wook lipping alround 35 mm thick, with necessary adhesives and CP screws complying with standard specification.The cost is inclusive of 1 No Lock arrangement, handel, tower bolt ,approved equivalent make SS ball bearing hinges of quivalent make of aproved make, 2 no floor mounted SS door stopper etc.complete as per drawing.
Supply & Fixing of 35mm thk.Double leaf high density interior grade marine plywood shutters pasted both sides 1.5mm thk.laminate approved design with 35x12mm T.W.lipping on all edges with necessary adhesives and CP screws complying with standard specification.The cost is inclusive of 1 no Lock arrangemen,handel,tower bolt ,approved equivalent make SS ball bearing hinges of quivalent make of aproved make,2 no floor mounted SS door stoper ect.complete as per drawing. Make:Kutty,Sharon,Trojan. Accessories Make:Dorma, Godrej.
Providing and fixing welded M.S. grills to the window openings,along the details as per drawing with necessary screws, bolts and fixed with necessary M.S. lugs embedded in masonry with C.C. 1:2:4 and finishing the surface neatly. Rate shall welding and consumables, etc. complete, as directed. Design of grills and the size of members to be used shall be got approval before put into use & as directed by the Engineer-in-charge.
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of all materils, Labour charges for cutting, bending, welding, grinding, polishing, Transportation, electrical charges, etc. complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors including cost of priming coat etc., complete complying with standard specification. ( The make quality and colour of paint should be got approved by the executive Engineer before use on works.)
Painting new wood work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Providing and applying Emulsion paint finish of approved make & shade in two coats over a coat of approved primer and 2 coats of patty to give an even shade as per manufacturer's instruction to the internal plastered surfaces including preparation of surfaces, scaffolding etc. all complete as per drawings and specification for all heights.
Providing and applying Emulsion paint finish of approved make & shade in two or more coats over a coat of approved primer to give an even shade as per manufacturer's instruction to the external plastered surfaces and internal ceiling plastered surfacesincluding preparation of surfaces, scaffolding etc. all complete as per drawings and specification for all heights.
PLUMBING WORKS:- EWC:- Supplying and fixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm "P" or "S" trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittingssuch as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications. (The EWC and flushing tank wiht all accessories should be got approved by the Executive Enginer before use on works)
Supplying and fixing white colour glazed Indian water closet, Orissa pattern Parryware or equivalent, with PVC, P or S trap having 110mm dia outlet and 50mm deepwater seal, embedding trap and water closet in cement concrete in 1:4:8 mix.
Providing and keeping in stores, shifting to the place of installation, fixing, testing and commissioning of white viterous china white color large flat back urinal with CP angle cock spreader flushing supported by CI/MS bracket including built in was
Supplying and fixing of 15mm CP two way bib cock with health faucet of parryware or equivalent make conforming to BIS specification and quality including cost of shellac, thread etc., complete complying with standard specification and including cutting and threading wherever necessary.
WASH BASIN:- Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia "B" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works).
Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks).
Over head Shower: Supplying & Fixing in postion of CP Shower Rose with CP Stop cock arrangements of size 15mm inlet 100mm outlet to the pipe line with necessary cutting, threading and jointing using shellac Etc.,Complete complying with standard specification and as directed by departmental officer. ( The CP Shower rose should be got approved by the Executive engineer before use on Works
Supplying & fixing of Angle valve stopcock with connecting hose and wall flange. (Make: Parryware or equivalent)
Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc.,complete complying with standard specifications. (The tower rail should be got approved by Executive Engineer before use on works).
Supply & fixing C.P soap tray of approved quality (Parryware or equivalent) including cost and conveyance complying with standard specification.
Supplying & fixing of Long body Bibcock with brackets including fixing over Wall tile dado complete.(Make: Parryware or equivalent)
PART - B SOIL AND WASTE PIPES Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition,including testing for any leakages,etc.,complete complying with standard specifications.(The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below Stilt level.
40mm dia
50mm dia
75mm dia
110mm dia
Supplying and fixing in position cost iron Nahini / Floor trap with Stainless steel grating / PVC nahini / Floor Trap with PVC Grating type of size 100 x 75 / 75 x 50 mm with best quality gratings of approved brand fixed over a bed of brick jelly lime concrete 1;2;5 (One lime two sand and five aggregate ) brick jelly 40mm and finishing with cm 1;3(One cement and three sand) including dismantling masonary wherever found necessary and making good to the original condition and giving connections to the cast iron pipe etc, complete complying with standard specififcation and as directed by the departmental Officers.
RAIN WATER PIPE:- Supply and fixing in position best quality PVC IS 4985 - CLASS-II - 4 Kg/Sqcm -Rain water pipes of various size having ISI mark and providing leak proof joints with such as Bend, Tee Junction, door etc.,of approved qualityincluding fixing to the wall with special PVC /MS clamps, etc., and making connection to all sanitary fittings, wherever necessary and making chipping good to the original condition, complying with standard specification etc.,complete.
110mm dia
PART-C EXTERNAL DRAINAGE Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level
75mm dia
110mm dia
160mm dia
GULLY TRAP:- Supplying and fixing in position 150 x 100mm "P" or "S" stoneware gully trap 'A' grade with CI double gratings of size 150 x 150mm and 230 x 230mm at bottom and top respectively with necessary earth work excavation laid over a bed of brick jelly cement concrete 1:3:6 (One cement, Three sand and Six broken brick jelly) 150mm thick using 40mm size broken brick jelly including necessary brick work and plastering including dismantling masonry wherever necessary and re-doing the damaged portions to the original conditions using cement concrete 1:3:6 using 20mm stone jelly for fixing the gully trap and giving connections to stoneware sewer line etc., complete complying with standard specifications. [Earth work excavation, brick work, plastering shall be measured and paid separately]. The stoneware gully trap should be got approved by the Executive Engineer before use on works.
Construction of INSPECTION CHAMBER following clear sizes including earth work excavation, CC 1:5:10 of 10 cm thick and brick work in Cement Mortar 1:5 [One cement and Five sand] using best quality of second class Table Mould Bricks of size 9" x 43/8" x 23/4" with Plastering with Cement Mortar 1:3 [One Cement and Three Plastering Sand] 12 mm thick to inner and outer sides and wearing coat 1:3:6 [One Cement, Three crushed stone sand and Six Aggregate] 15 cm thick and covered with precast slab 5 cm thick etc., complete complying as directed by the departmental officers as per standard specification.
INTER CONCEALED WORK:- Providing, supplying & laying of Chlorinated Poly Vinyl Chloride (CPVC-SDR-11) Pipes conforming to IS 15778 having thermal stability with brass and CPVC fittings like Elbow, Brass Tee, Brass Elbow, Offsets, Tee with clamps @1.00 meters spacing, with jointing of pipes with one step CPVC solvent cement with including cutting of chase including testing of the joints complete and making good the walls etc. Rate is inclusive of all material labour, transportation, tools & tackles taxes, etc all complete as per as per specifications, Exposed work including chase cutting, bracket fixing)complete complying with standard specification and as directed by the Departmental Officer.
20mm dia
25mm dia
32mm dia
PART F.EXTERNAL PLUMBING WORKS Providing, supplying & laying of Unplasticized Polyvinyl Chloride (UPVC-SDR-11) Pipes conforming to IS 15778 having thermal stability cold water with brass and UPVC fittings like Elbow,Brass Tee, Brass Elbow,Offsets,Tee with clamps @1.00 meters spacing, with jointing of pipes with one step UPVC solvent cement with including cutting of chase including testing of the joints complete and making good the walls etc.Rate is inclusive of all material labour, transportation,tools & tackles all complete as per as per specifications,Concealed work including chase cutting) complete complying with standard specification and as directed by the Departmental Officer.
32mm dia
40mm dia
50mm dia
Providing, supplying & laying of Gunmetal type NRV - pressure rating less tahn 16 Kg/Sqcm and IS778 with 2 Nos of MTA with jointing material like shellac, thread including testing of the joints complete and making good the walls etc. Rate is inclusive of all material labour, transportation, tools & tackles taxes, levies VAT etc all complete as per as per specifications, complete complying with standard specification and as directed by the Departmental Officer
32mm dia
40mm dia
50mm dia
Supplying and erection of horizontal shaft centrifugal mono block power pump set of single phase 2.00 H.P of best approved quality and make with ISI mark on suitable pedastal with foundation bolt and nut including labour supplying and fixing of starter and main switch suitable for 2.00 H.P pumpset on suitable angle iron frame work with necessary labour including panel board, supply and run off 4 of 10 Sq,mm, in P V C pipe with 14 SWG TC wire including fixing of suction pipe and foot valve up to a maximum depth of 7m and delivery pipes upto the exterior wall of pump room etc., complete and operating the pumps on trial run for 3 days. (The make and quality of pump set to be got approved by the Executive Engineer before use on works.) (TWAD- Pa no:103 Sl.no:45)200mx60m
BOREWELL:- Drilling of bore wells in alluvial soil or sedimentary strata of clay and sand or sand stone, shale, pebbles, boulders etc., by first taking a pilot bore of 150 mm dia and then enlarging to the required dia by direct or reverse rotary mud circulation method including charges for all T&P, cost of fuel, labour charges, bentonite mud and water required for drilling at the site shown by the departmental officers including construction of mud pit etc., complete.
Upto 60 m Depth ending below ground level
From 60 m to 90 m Depth ending below ground level
Reaming 150mm dia Pilot bore to 300mm dia bore as directed by the departmental officers upto required depth
Upto 60 m Depth ending below ground level
From 60 m to 90 m Depth ending below ground level
Supplying, and fixing the following size of PVC pipes of approved quality and variety conforming to pressure IS 4985. The rate is inclusive of cost of pipe, all taxes, conveyance charges of materials and all other labour charges for fixing the PVC pipe as directed by the departmental officers etc., complete complying with standard specifications. The PVC pipe should be got approved by the departmental officers before use on work and Labour Charges for insering PVC casing pipe assembly (with slots and without slots) in the drilled holes including jointing the pipes with PVC couplers with PVC adhesive etc., complete and supplying and packing annular space with pebbles of size and quality as approved by the Departmental Officers.
150mm dia PVC Casing Pipe (With or without Slot)
Charges for developing Borewell with air compressor of 600 CFM capacity (Min 8 Hours) including transportation and labour and fuel charges for the compressor as directed by the departmental officers and conducting yeild test by 'V' notch methods, excluding cost of bore charges and conveyance charges for handling boring
Supply, errection and giving necessary water supply and electrical connections of new type 2 HP submersible pumpset confiming to IS-14220 with ISI mark suitable for 150mm borewell, complete complying with standard specification including suitable 3-phase panel board with DOL with two level guard starter and accessories and Labour charges for the erection of submersible pump set in bore well including fixing and jointing the submersible cable ( but excluding cost of 2.50sqmm - 3core copper cable)with proper clamps upto othe starter to the required depth, valves section clamps, pressure gauges upto the exterior wall of the panel board consisting of JPICN switch starter, voltammeter, ammeter, 3 pilot (indicating) lamps, capacitor, single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per I.E. rules etc. complete and testing pump sets on trial run for 3 days etc., complete complying with standard specifications. with Three phase panel board
Supplying and fixing HDPE pipe for sub-mersible pump in Bore well (class-5 1 MPa or 10 Kg / cm2 pressure) of best approved quality including welding wherever necessary etc., complete as directed by the Executive Engineer. The pipe should be got approved by the Executive Engineer before use on works.
40mm dia
50mm dia
Suppling and fixing PVC bore well end cap of size 165/168mm dia etc., complete complying with standard specifications as directed by departmental officers
Supply of 4.00 Sq.mm / PVC insulated and sheathed, 3 core flat type copper cable for submersible motor complete complying with standard specifications as directed by departmental officers
Supply and fixing the Nylon Rope to connect the Submersible motor in borewell etc., complete complying with standard specifications as directed by departmental officers
ELECTRICAL WORK:- Wiring Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) (Higher End )
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) (Higher End ) (
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories with suitable Module GI switch box in flush with wall with 1 no. 6A one way module switch and 1 no. 6A 3/2 pin module socket with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with painting of suitable colour for concealed PVC pipe Plug point ( 8 points / Coil) Higher End
Light Fixture & Fans Supply and fixing of 4' 20W LED fitting with LED on wall or ceiling with PVC unsheathed copper leads from terminals to the fitting (Higher end)
Supply and fixing of WT bulk head fitting with guard suitable for 15 W LED Bulb
Supply and fixing of 20W LED Mirror light fitting on wall or ceiling with PVC unsheathed copper leads from terminals to the fitting (Higher end)
supply and fixing of 24W LED 2x2 square type surface/ Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting.
supply and fixing of 30W LED street light fitting with LED (Higher end) with 25mm dia. GI pipe (class B) with 1 no.25 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting .
supply and fixing of 60W LED street light fitting with LED (Lower end) with 32mm dia. GI pipe (class B) with 1 no.32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting .
supply and fixing of 1200mm (48") sweep AC ceiling fan complete ( Higher end) with 2 module 100W fan step regulator (Higher end) with 1 metre down rod on the existing fan clamp
Supply and fixing of 450 mm sweep wall mounting fan (Higher end) on wall with all necessary arrangments and testing complete.
Supply and fixing of 35W LED Well Glass , Aluminimum Housing with PC diffuser with roboust construction and high specifications for sustained lighting performance in harsh conditions. Product is deisgned for Ingress protection of IP65 and Impact resistance of IK08 with Eye Bolt and Cradle mounting assembly options (Higher end) at Galley area
Supply and fixing of 95Watts LED highbay designed to deliver excellent efficiency at 160lm/w and right optics suited for various applications. Offering excellent beam and glare control with suitable hanging support with connection complete at auditorium
Supply and fixing of 300mm (12") sweep (Heavy duty) AC exhaust fan complete with necessary wall opening and making good of the wall
Supply and fixing of louvers shutters arrangements for 300mm (12") sweep (light duty) AC exhaust fan
Wall Sockets Supply and fixing of 2nos.6A two module 3 pin socket , 2 nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End
Supply and fixing of 25A Flush type Wall Socket 25A DP MCB complete set for AC Plug in flush with wall with earth connection (For AC Plug)
Supply and fixing of 1no.6A two module socket , 1 no. 6/16A two module socket, 1 no. 6A one module switch, 1 no.16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End
Meter Board Supply and fixng of TNEB meter board suitable for 3 phase 100A service connection made up of suitable angle iron frame work of size 2 feet x 1-1/2 feet using angle iron of size 1-1/2" x 1-1/2" x 1/4" rigidly fixed on wall covered with hylem sheet of size 2 feet x 1-1/2 feet of 12mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos. 100A fuse units (500V), 1 No. neutral link, copper earth flat of size 1" x 1/4" with inter connection of EB meter to fuse units by 16 Sq.mm PVC insulated copper wire with earth connection complete
Distribution Boards Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End
Supply and fixing of 4 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63A 4P MCB switch as incoming and 1 no. 32A 3P MCB , 9 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End
Supply and fixing of 4 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A 4P MCB switch as incoming and 12 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End
Supply and fixing of 4 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63A 4P MCB switch as incoming and 12 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End
Supply and fixing of 6 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal door) with 1 no.32A 4P MCB switch as incoming and 18 nos. 6-32A SP MCB as outgoing with suitable cable end box in flush with wall with earth connection only. Higher End
Run of mains and UG cable Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire and making good of the concealed portion
Supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire and making good of the concealed portion with suitable colour
Supply and run of 4 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire and making good of the concealed portion with suitable colour
Supply and run of 4 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 6 sq.mm copper wire and making good of the concealed portion with suitable colour
Supply and clarnping of 2x4 sq.mm. PVC LTUG armoured copper cable on post or on wall with MS clamps
Supply and Laying of 3 1/2 x 95 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.
Supply and clarnping of 3 1/2 x 95 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps
Supply and fixing of brass cable gland for 3-1/2 x 95 sq.mm. PVC armoured LTUG cable with earth connection
Supply and providing cable end termination of 3-1/2 x 95 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete
Main switches & Panel Supply and fixing of 100A TPN switch disconnector fuse units in sheet steel enclosure with HRC fuses double break on suitable angle iron frame work with MS cable entry boxes with earth connection only.
Supply and fixing of 100 A Three phase 500V 4 Pole Change over Switch on suitable angle iron frame work with MS cable entry boxes with earth connection only
Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than 40mm with copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry
Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection
Supply of Passenger Lift MRL (16 Person Capacity), Speed 1.5 m/s with Stainless Steel Panels, Disable friendly, microprocessor based controller, VVVF drive, Fire rated doors and ARD.
TECHNICAL SPECIFICATIONS- 1) Location: INDOOR STADIUM 2) No. of lifts / Type of Lift: One/ Liftpassange 3) Capacity of lift: 8 persons capacity (544 Kgs) passenger lift 4) Speed: 1.50 Mtr Per Second. 5) Type of Drive, Microprocessor based VariableVoltage Variable frequency (V3F) drive with enhanced ride comfort and levelling functions 6) Position of Machinary. Directly above the lift well Gearless 7) No of floors: G+1 (2 landing) 8) Total travel: 7.8 Mts 9) Leveling accuracy- High level accuracy with smooth and jerk free stopping 10) Design of car: Stainless Steel hairline finish combination car body with SS finish ceiling (sleek medium circular LED lights, regular circular fans SS Handrail & PVC flooring ) 11) No. of landing entrance ; 2Nos (G.F+ F.F ) 12) No & position of car entrance one in front only 13) Size of lift well: 2250 x 1900mm (width x depth)
27) Steel for lift machinary To be provided by the lift contractor. 28)Servicing and maintenance: Lift contractor should provide free comprehensive servicing and maintenance during the guarantee period. 29)Automatic Rescue Device To facilitate the landing of the lift to the nearest floor at the time of power failure This shall consists of suitable type battery system with charger, invertor, under voltage protection system etc Complete with all accessories. 30) Provision if Intercom with phone. To be provided by the lift contractor 31) Lift license Preparation of drawings, lift contractor should do payment of charges to CEIG and insurance policies if any and obtaining CEIG safety certificate as per lift act.
32) Floor announciator with music. To be provided in the car 33)Special features: (a) Battery Operated Emergency Light and Alarm (b) Call Register Signal And Vf Door Operator (c) Automatic Rescue Device. (d) Stainless Steel Button with S S. Cover. (e) Dot Matrix Led D & P Indicators in Car & Landings-Orange Colour. (f) Floor Annunciator with Music (g) Firemans Switch (h) False Ceiling in Car (i) Fire Rating of Landing Doors-One Hour (j) Infra Red Door Screen (k) Overload warning Indicator (1) Laminated Mirror At Rear Side. (m) Scaffolding (n) Two way Intercom with press & speak in Cop (o) Provision for EBABX (p) Free Service for One Year (q) Pit Ladder (r) Ss Handrail
(s) Lift License (t) Minor Builders Work (u) Provision for Cctv Camera lp (Cat6 Flat Travelling Cable) 34) Over speed governor, phase failure and phase reversal relay, alarm bell, T Guide brackets for car and counter weight, rubber padding under winding unit, motor of adequate capacity, electro magnetic brake with compression spring etc. 35) Guarantee: Gurantee for the materials and lift firm should offer workmanship of equipments complete for a period of not less than one year.
SOLAR PV Design, supply , Installation , testing and commissioning of 15 KWp On Grid Solar PV Plant comprising of: i) Solar panels of type Mono Crystline, PERC, etc. ii) Power Conditioning Unit (PCU)with MPPT, Inverter, Controls, Protection Devices, Interconnecting D.C. cables, Connectors, Junction Boxes and accessories. iii) D.C. D.B iv) A.C. D.B v) A.C. cables and accessories vi) Lightning arrestor, earthing, etc. vii) Module Metallic Mounting Structures viii) Installation, Testing and Commissioning corresponds to BIS and IEC requirements
TECHNICAL SPECIFICATIONS 1. SOLAR PV MODULES AND ARRAY (i) Only indigenous modules shall be used in the Solar module shall be Mano Crystalline(or) Concentrator Py modules type. The peak power output of |the PV Module shall be min 550Wp under STC. Module Voc shall be minimum 21V., The total array capacity shall not be less than required capacity and this shall be operating at the required DC voltage. The power output of the PV module must be reported under standard test conditions (STC), 550 WWp watt modules of the sample |module should be submitted. The Rating of the Blocking Diode should be 15Amp The Efficency of the modules should not be less than 18% (ii) The mechanical structure shall withstand gusts of wind cyclonic wind up to 150km/hr from back side of the panel. iii) The offered modules must conforn to the latest edition of any of the following IEC equivalent BIS
iv) In addition, the modules must conform to IEC 61730 1- requirement, for construction &Part 2 - requirements for testing, fos safety qualification or Equivalent IS (Under Dev.) v) SPV modules shall be certified by NABL/IECQ accredited test centre. The bidder shall submi appropriate certificates. vii) Protective devices against surges a |the PV module shall be provided. Low voltage drop bypass diodes shall be provided viii) Module Junction box (weather proof), where the module terminals shall be interconnected and output taken, shall be designed for long life out doo operation in harsh environment as pe he relevant BIS specifications anc protected agninst surges. It should have provision for "Opening" for replacing the cable, if required. ix) PV modules used in solar poweu |plants must be warranted for output wattage, which should not be less than
h. Date and year of oblaining IEC PV module qualification certificate i) Name of the test lab isuing IEC certificate j) Other elevant information or traceability of solar cells and module as per 1SO 9000 series RFID shall be mandatorily placed inside the module laminate 1.1 ORIENTATION AND TILT OF PV MODULES Modules shall be North -South oriented althe Tilt Angle of 8.4977 N, 78.1194 E
2 MOUNTING STRUCTURES The PV modules will be mounted os fixed metallic structures of adequate strenoth and appropriate design, whick can withstand lond of modules and high wind velocities up to 150 km per hour. The support structure used in the power plants will be hotdip Galvanized Iron (G.). The "Mounting Structure" should have the following features: |-The modules support structure shall be Mild Stcel /hot dipped Galvanized (atleast 120 micron) Iron for holding the PV modules. The size of angle iron as ner site condition as instructed by the |site engineer.Each panel frame structure shall be so fabricated as to be grouted on roof on its legs. The legs of the structure shall be fixed and grouted in the PCC foundation column made witl 1:2:4 cement concrete.The foundation shallsupport SPV |modules at a given orientation, absorb and transfer the mechanical loads to the |ground properly and shiall withstand…
3.JUNCTION BOXES The junction boxes shall be dust proof, vermin and waterproof and made of FRP / Thermo Plastic. The terminals be connected to copper bus- bar shall arrangement of proper sizes. The junction boxes shall have suitable cable points fitted with eable glands of entry appropriate sizes for both incoming and outgoing cables. Suitable markings shall be provided on the bus-bar for casv identification and cable ferrules shall be fitted at the cable termination points fo identification. Each main junction box shall be fitted with appropriate rating blocking diode. The junction boxes shall be of reputed make. 4. POWER CONDITIONING UNIt (PCU) The PCU shall also house MPPT (Maximum Power Point Tracker), an interface between Solar PV array & the Inverter, to maximize Solar PV array energy input into the System. PCU including MPPT & protection conform |toIEC 61683/IS 61683, IEC 60068-
DETAILED SPECIFICATION 1)DCArray InputVoltage :-20% to +15% of the Operating DC Array voltage in Sl. No. 1 above 2) Type of Solar Charge Controller: MPPT Based Solar Charge Controller 3) Switching device: MOSFET/ IGBT based 4) Output Wave Form: Pure Sinc Wave Output |5) Total Harmonic Distortion : < |3% with resistive load 6)Output Voltage 230+ 3 % in case of 1 phase PCU 400+ 3 % in casc of 3 phase PCU 7)Output Frequency : 50 HZ 4 0.5 Hz 8) Power Factor: > 09 9) PCU efficiency -:>90% at nominal yollage &power 10) Idle Current < 4% of rated capacity 11) Regulation:Line regulation & Load regulation -2 % 12)Cooling Forced Air cooling controlled cooling fan
INVERTER: The power conditioning unit/inverter should be grid interactiveand also DG set interactive if necessary. Inverter output should be compatible with the grid frequcncy. Nominal AC O/P voltage and frequency: 415V, 3-ph, 50Hz Accuracy of AC voltage control Output frequency : +1% Output frequency 50 Hz Accuracy of frequency control +0.1% Grid Frequency Synchronization rang +3Hz Maximum inverter Dependant Ambient temperature considered 40°C Humidity :95% Non condensing Protection of Enclosure IP-20(Min) Indoor, 1P-65(Min)Outdoor Grid Frequency Tolerance range +3% Grid Voltage tolerance : -20% & -+15% No-load losses : <1% of rated power Inverter efficiency(minimum) >95% THD % : <3%
5.DC & AC Swiches a DC SIDE (i) MCB of suitable rating shall be provided for connection and disconncction of aray & PCU for maintenance purpose. (ii) Switches and Circuit Breakers on sideshalibe DC ruted or they shll be sufficiently de- rated , if AC rated switches are used, b.AC SIDE suitable rating shall be MCB of provided for connection and |disconnection of PCU & 1oad 6.Cables and accessorie All ha ables shall b supplied conforming to IEC 60227/1S 694 & IEC 60502/IS 1554 shall be of 1.1 kV grade as pet requirement. Only PVC copper cables shall be used. The size of the cables between array interconnections, array to junctior boxes, Junction box to PCU, PCU to AC Distribution Box ete shall be so sclected to keep the voltage drop and losses to the minimum Permissible Wire Drop on DC side shal <10 The bider sbhall upply installation nccessories, which are required to instal and successfully commission the powe plant.
7.Earthing and Lightning Protection: Earthine: The array structure of the PV yard shall be grounded properly using adequate number of earthing kits. All metal casine or shicldine of the power plants shall be thoroughly grounded to ensure safety of the solar power plants Lightning: The SPV power plants shall be provided with lightning &over voltage |protection. The main aim in this protection shall be to reduce the over voltage to a tolerable valu before it reaches the P or other sub system components, The Source f over voltage an be lightening. atmosphere disturbances etc
8.INTEGRATION OF PV POWER WITH GRID: The output power from SPV would be fed to the inverters which converts DC produced by SPV array to the AC and r-ode it into the main electricity grid lafer svnchronization. In case of grid failure, or low or high voltage, solar PV system will be out of synchronizatior and will be disconnected fromn the grid Once the DG set comes into s service PV |system will again be synchronized with DG supply and load requirement would be met to the extent of availability of power 4 pole isolation of inverter output with respect t he gridDG power |connection need to be provided.
9.GRID ISLANDING: PV svstem software and control system will be equipped with islanding protection. In addition to disconnection from the gird (islanding protection t.e on no supply), under and over voltage conditions will adequate ratine fuses fuses on inverter inout side (DC) as wel as output side (AC) for overload and short circuit protection and disconneeting switches to isolte the DC and AC system for maintcnances as needed. Fuses of adequate rating will also be provided n ach solar arra: module to protect them against short circuit. A manual disconnect 4 pole solation switch beside automatis tisconnection to grid would have to be provided at utility end to isolate the grid connection by the utility personal to carry out any maintenance
10.WARRANTY (i) Solar panel at 90 % efficicncy - 10 years (ii ) Solar panel at 80 % efficiency -25 years (i ii) All other cquipments ycars WARRANTIES & GUARANTIEES The goods supplied under this contrac are new. unused. of the most recent or latest technology and incorporate all recent improvements in desien and materials. This warrantee will also be covering the rectification of any and all defects in the design of equipment matcrials and workmanship includin spare parts for the guarantee period specified by MNRE/ TEDA from th date of commissioning. All the Guarantees Wartintes of the dirent components will be transferred to Owner of the project. 11.Make_ofthe.Component (i) Indigenous MNRE approved Multi Crystalline modules- Adani/ Goldi /Loom Swelece/ TATAViamWale/ Rayzon Equivalent |(ti)ON grid Inverter ( PCU)- Grow Watt K. Solarie/ Polycab/ Evvo/ Salie /Goowe/ solis/Solox Equivalent
Supply and fixing of 63A 4P MCB with sheet steel enclosure in flush wall with Earth connection (Higher end)
Supply and clarnping of 4 x 10 sq.mm. PVC armoured Copper LTUG cable on post or on wall with MS clamps
Design, Supply, erection, Testing, Commissioning and handing over of 12 metre Mini Mast Structure (Bajaj / Philips / Crompton make or equivalent) with required number of continuously tapered hot dip galvansied steel polygonal side sections with telescopic strip joints to a total of 12 meters capable of sustaining the maximum
wind pressure at the erection site with single flange base mast section with vertically movEable hot dip galvanised lantern carriage and accessories such as electrical junction box brackets for providing 6 Nos of 150W LED flood light luminaries with control gEar box complete hEad frame assembly, pulley drive stainless steel wire
rope single / double drum self-lubricating winch arrangements suitable for raising and lowering the luminaries carraige ring flexible multi core power cable and necessary high tensile hot dipped galvanized foundation, bolt & nuts along with washers and templates including supply and fixing the following accessories in the
Mast design and casting of suitable foundation with 1:2:4 mix RCC concrEate with 30cm projection above the ground level with 1 Mt width x 1Mt length x 2 Mts depth with necessary galvanised foundation bolts nuts and washers and dump plates enclosing the bolts nuts for high mast cosidering the safe soil bEaring capacity at site-1 Set
b) High powered power tool with complete with hand held control panel and motor with push button type remote control switch suitable for 3 phase 415 V /50 HZ for raising and lowering of the lantern carriage complete to operate all fittings mounted in the base to couple with winch-1 Set
c) Feeder pillar box comprising of 0.90m x 0.45m x1.20m floor angle iron frame with 63 A power contactor starter for the 3 Phase motor-1Set
d) Neon aviation obstruction light (Bajaj/equivalent) - 1No
e)2Nos of special GI Earth electode with copper plate 300 x300x3mm and copper flat (1"x1 1/4")inter connection as per ISS complete with Earth connections-1Set
f) Hot dip galvanised lighting arrester- 1 No
(Data AA)
Supply and clarnping of 4C x 16 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the Earth to make good.
Supply and clarnping of 4C x 16 sq.mm. PVC armoured LTUG aluinium cable on post or on wall with MS clamps
Supply and fixing of brass cable gland for 4C x 16 sq.mm. PVC armoured LTUG Aluminium cable with earth connections
Supplyandprovidingcableendterminationof 4C x 16 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete
Supply and erection of hot dip GI double arm octagonal poles of 7 Mt length and necessary GI pipe bend and luminalre with MCB control and cable entry (complete including all civil work for founadation etc.) with supply and fix of 2 Nos 150W LED street light as per specification with RCC civil foundation and U bolts & Nuts
Supply , Erection Testing and commissioning of 415V/50 HZ 125A Cubicle panel board with centre switches Chamber the bus bar chamber and cable chamber on extreme end with 16 SWG thick CRCA sheet with 1”x 1/8 ” tinned copper flats for 3 phases and neutral with 6mm hylem sheet separation of 3 phases and neutral and with synthetic moulded insulators bus supports at equal intervals as per IS specification and 2 runs of 1”x 1/8” copper flat on rear side of the panel board for earth buses and Digital Multifunction meter.with suitable CT coil , with 3 nos. LED pilot lamps set withfuse base, top & 10A HRC Fuse link for 3 phases on a separate Chamber and with the following switches complete.
a)125A TPN switch disconnector fuse units interior only with HRC fuse double break -1no.
b)63A TPN switch disconnector fuse units interior only with HRC fuse double break -5 nos.
c)32A TPN switch disconnector fuse units interior only with HRC fuse double break 3 nos.
Sub Total
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.42 MB
Chinnakalaiyamuthurpart1.pdf
Tender Documents • 1.29 MB
Chinnakalaiyamuthurpart2.pdf
Additional Documents • 1.49 MB
11.pdf
Additional Documents • 1.11 MB
BOQ_786004.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid