| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Others-Tender cost and EMD registration etc not uploaded by the Contractor |
Tender Value
₹5.7 L
EMD Value
₹11,500
Closing Date
29 Mar 2025, 6:00 pmClosed
Nodal Officer (Tender)
O/o Sr. Chief Engineer(Civil) BSNL MP Civil Zone Block-C, BDA Flats, First Floor, Vidya Nagar, Behind Petrol Pump Hoshangabad Road , Bhopal (M.P.)- 462026
External repair work and other miscellaneous external civil works in TIV Annexie block no 32 to 37 and 38 to 42 in BRBRAITT Jabalpur MP
2025_BSNL_230610_1
NIT NO. EECD/BSNL/JBP/2024-25/25
Open Tender
Civil Works
Item Rate
90 days
Jabalpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Accounts Officer Cash Oo GMTD BSNL Jabalpur
₹11,500
8 Apr 2025
20 Mar 2025
1 Apr 2025
20 Mar 2025
29 Mar 2025
20 Mar 2025
Amount
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift up to 1.5 m, as directed by Engineer-in-Charge:
All kinds of soil
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift upto1.5 m.
All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, bases of columns, etc. for mass concrete
Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:
Cement Mortar 1:6 (1 cement : 6 coarse sand).
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.
Using M.S. angels 40x40x6 mm for diagonal braces
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Hot finished welded type tubes.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
(i)Single socketed pipes. 110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
Single pushfit Coupler : 110mm
Bend 87.5°110mm
Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge.( Note;-Agency will submit 5 years bond as per applicable annexure of DNIT after execution of work).
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer, of required shade and colour all complete :
Old work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
Two or more coats on new work.
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade :
Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface.
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-harge.
With cement mortar 1:4 (1 cement : 4 fine sand).
Carrying and putting upto 50 mm thick plain stone cover of size upto 600x600mm over drain , manhole or places as decided by Engineer -In -Charge ( Flag stone is available near campus near Vikram Bhawan)
Cleaning of drainage manholes and sewer lines by removing the deposited and other rubbish from the manholes and cleaning the sewer lines by rodding and flushing with water as directed by the Engineer -in- charge. (Rate per One manhole and sewer line from previous to next manhole) including disposal of sludge out side the campus in MC dumping ground all complete as per direction of Enginneer -In -charge,
Repairing of steel door frame , shutters with electric welding and providing necessary accessories like cleat, angle, M.S sheet hinges (as per requirement) etc.and fixing to wall if damaged with appropriate steel hold fasteners all complete as directed by Engineer-In-Charge
Repairing of steel section window including frame with electric welding by providing & fixing necessary hinges/peg stays wherever required etc. all complete to open/close the window smoth/properly as directed by Engineer-In-Charge
Cleaning of window chajja including removing all grass & other dumped material etc and repairing for any damage all complete as directed by Engineer-In-Charge.
Repairing of man hole of size 90x90x90cm or more to bring in desired slope to next manhole including excavation, brickwork, concrete 1:2:4 and making necessary channel and plastering wherever required etc complete as per direction of enginear in charge.
Repairing of gully trap chamber of any size including excavation, brickwork, concrete 1:2:4 and making necessary channel and plastering wherever required etc complete as per direction of enginear in charge.
M/s K.K.Sutrakar (BID ID -835812)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .