Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹56.7 L
EMD Value
₹1.1 L
Closing Date
16 Oct 2026, 3:00 pm4d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
EE(E)/ELD-5/DDA
CENTRAL NURSERY SECTOR 5 DWARKA NEW DELHI
Replacement of 4, 5 mtr street light G.I. Octagonal poles along with fittings and other accessories at Metro corridor sector-14 Round about towards sec-16 and other service lanes of Master plan roads of Dwarka
2026_DDA_929727_1
29/EE/ELD-5/DDA/2026-27
Open Tender
Electrical Works
Works
45 days
EE(E)/ELD-5/DDA
Please refer Tender documents.
15 documents required · 15 mandatory
₹0
₹1.1 L
Yes
9 Oct 2026
9 Oct 2026
17 Oct 2026
9 Oct 2026
16 Oct 2026
9 Oct 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying, replacement, testing and commissioning of HOT Dip galvanized octagonal steel pole of 4 mtr height and made of 3 mm thick sheet, having bottom 130 mm OAF & top 70 mm OAF provided with welded base plate of size 200 mm x 200 mm x 12 mm thick inbuilt control box 1.0 mtr above the base plate, complete with 250mm wide 3 mm thick hot dip galvanised MS strip in octagonal shape welded permanenty around on window cover/junction box i/c providing L-hook in opposite side of control box just below the M.S. strip provided on juncion box/cover box of suitable projection from the pole shaft to prevent the movable junction/cover box going down to the base plate and making a suitable size of hole on above the L-hook (600 mm approx) to hold the junction/cover box during the maintenance i/c covering with MS cover arrangement the hole to prevent entry of rain water through it, complete as per drawing & technical specifications attached & providing following accessories with mounted inbuilt control box having flush cover with 2 nos. mounting strips with tapped holes on existing RCC foundation with bolt and nuts, making connections, interconnections with suitable size of copper wire with thimble/lugs in the connector box, earthing, marking/ numbering of pole etc. complete as per drawing & technical specifications attached including following accessories with mounted inbuilt control box.
(a). 6mm thick phenolic laminated/Bakelite sheet inside the window mounted on the existing mounting strips inside the flush door.
(b). 1 no. 63 Amp terminal block suitable for following conductor / cable, fixed on DIN channels i/c providing and fixing DIN channel of suitable length – on the existing phenolic laminated / Bakelite sheet.
(i) 10 sq mm conductor – 2 nos. (incoming and outgoing looping)
(ii) Terminal suitable for 6 SWG GI wire / 2.5 sq mm wire.
(c). 6 Amp, SP MCB,10 KA, ‘C’ Series – 1 no. including mountings on DIN channel, Earth stud 2 Nos. welded at suitable height i/c washers, springs washers & nuts etc.
(d) Suitable arrangement for saddling of incoming / outgoing cables. | 45 | Each | 7,201 | ₹3,24,045 |
| 2 | Supplying, replacement, testing and commissioning of HOT Dip galvanized octagonal steel pole of 5 mtr height and made of 3 mm thick sheet, having bottom 130 mm OAF & top 70 mm OAF provided with welded base plate of size 200 mm x 200 mm x 12 mm thick inbuilt control box 1.0 mtr above the base plate, complete with 250mm wide 3 mm thick hot dip galvanised MS strip in octagonal shape welded permanenty around on window cover/junction box i/c providing L-hook in opposite side of control box just below the M.S. strip provided on juncion box/cover box of suitable projection from the pole shaft to prevent the movable junction/cover box going down to the base plate and making a suitable size of hole on above the L-hook (600 mm approx) to hold the junction/cover box during the maintenance i/c covering with MS cover arrangement the hole to prevent entry of rain water through it, complete as per drawing & technical specifications attached & providing following accessories with mounted inbuilt control box having flush cover with 2 nos. mounting strips with tapped holes on existing RCC foundation with bolt and nuts, making connections, interconnections with suitable size of copper wire with thimble/lugs in the connector box, earthing, marking/ numbering of pole etc. complete as per drawing & technical specifications attached including following accessories with mounted inbuilt control box.
(a). 6mm thick phenolic laminated/Bakelite sheet inside the window mounted on the existing mounting strips inside the flush door.
(b). 1 no. 63 Amp terminal block suitable for following conductor / cable, fixed on DIN channels i/c providing and fixing DIN channel of suitable length – on the existing phenolic laminated / Bakelite sheet.
(i) 10 sq mm conductor – 2 nos. (incoming and outgoing looping)
(ii) Terminal suitable for 6 SWG GI wire / 2.5 sq mm wire.
(c). 6 Amp, SP MCB,10 KA, ‘C’ Series – 1 no. including mountings on DIN channel, Earth stud 2 Nos. welded at suitable height i/c washers, springs washers & nuts etc.
(d) Suitable arrangement for saddling of incoming / outgoing cables | 40 | Each | 8,254 | ₹3,30,160 |
| 3 | Providing and laying in position, M25 reinforced cement concrete foundation of size 400 mm (L) x 400 mm (W) and 1200 mm (D) i/c excavation of earth, providing cutting, bending and placing in position reinforcement of cold twisted bar of 12 mm dia. 1200 mm long (approx.) – atleast 8 Nos. and reinforcement ring of cold twisted bar of 10 mm dia. 1400 mm long (approx.)-atleast 10 Nos. (with 120 mm spacing) i/c supplying of 4 Nos. M-20 x 600 mm long (150 mm top threaded & 250 mm top galvanized portion) M.S foundation bolt (EN 8-grade) with 3 Nos. nuts and 2 Nos. washer, bolt along with 2 Nos. templates/Anchor plate of size 200 mm x 200 mm x 3 mm thick having 4 Nos. 20 mm dia. holes to match with PCD of poles base plate with positioning of foundation bolts and providing 63 mm (OD) 2 Nos. DWC pipe for cable entry/exit, plastering & painting the foundation above the ground level etc complete as required. | 85 | Each | 5,833 | ₹4,95,805 |
| 4 | Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP 66,IK-10, CRI >80, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver& electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C)
90 Watt | 130 | Each | 2,335 | ₹3,03,550 |
| 5 | Supplying of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP 66,IK-10, CRI >80, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver& electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C)
200 Watt | 400 | Each | 4,682 | ₹18,72,800 |
| 5.1 | 90 Watt | 100 | Each | 2,036 | ₹2,03,600 |
| 6 | Supplying & fixing of hot dip Galvanized minimum 1000 mm long Bracket (to be installed at 5 mtr height) made out of suitable sized round pipe B-Class on octagonal pipe (3.60 mm Thick), 48 mm outer dia with 300 mm long galvanized overhang with tightening bolts etc. as reqd. Tilt angle shall be around 10 degree.
a) Single arm bracket | 40 | Each | 1,764 | ₹70,560 |
| 7 | Supplying & fixing of hot dip Galvanized minimum 1000 mm long Bracket (to be installed at 4 mtr height) made out of suitable sized round pipe B-Class on octagonal pipe (3.60 mm Thick), 48 mm outer dia with 300 mm long galvanized overhang with tightening bolts etc. as reqd. Tilt angle shall be around 10 degree. a) Double arm bracket | 45 | Each | 2,412 | ₹1,08,540 |
| 8 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 1.5 sq. mm. | 620 | Each | 104 | ₹64,480 |
| 9 | Supplying of following size of XLPE insulated aluminium Conductor having stranded wire armourd power cable of 1.1 KV grade i/c making, connection testing etc. as reqd. a) 2C x 16 sq.mm | 3,050 | Mtr | 214 | ₹6,52,700 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.10 MB
NIT29PDF.pdf
Tender Documents • 6.98 MB
BOQ_977020.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .