Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.0 LAccepted-AOC | L1 | Accepted-AOC AWARD OF CONTRACT | |
| 2 | L2₹11.9 L+₹1.5 L (14.2%)Rejected-Finance B 68 MOTIKUNJ MATHURA 281001 UP | MATHURA | UTTAR PRADESH | 281001 | L2 | Rejected-Finance NOT LOWEST BIDDER |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
30 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Maj Mathews M Shepherd
GE (WEST) Mathura
REMOVAL OF BLOCKAGE OF SEWAGE LINE INCLUDING NECESSARY REPAIR AND DEWATERING/SLUDGE REMOVAL FROM SEPTIC TANK AND DISPOSAL TO OUTSIDE NEW RATC SHIVA JI AREA UNDER GE (W) MATHURA
2023_MES_606537_2
8300/1174/E8
Open Tender
Civil Works
Item Rate
180 days
GE (WEST) Mathura
AS PER NIT
9 documents required · 9 mandatory
₹500
GE (West) Mathura
₹30,000
Yes
21 Sept 2023
9 Aug 2023
6 Sept 2023
9 Aug 2023
30 Aug 2023
16 Aug 2023
Amount
Cleaning of sewage lines blocked/filled with sludge, semi solid/solid material etc man holes to manholes by sewage suction machine without causing any damage to sewage lines/manholes. Manholes covers and taking out the same and removing to a non inhabitant area or buried into ground all as specified for the following internal dia of pipes:-
150mm dia.
200mm dia
M & L for cleaning, de-silting and testing of manholes of any depth deep by pumping manually with required rope, buckets and ladders and depositing the sludge at distance n.exc 50mtr and then removing sludge outside MD land area all as directed by the Engr-in-Charge. Note :- The contractor shall remove the sewage / sludge and other foreign material from the site by mechanical equipment etc or by way or other any mean to outside MOD land in covered Vehicls ie Veh required for tpt of foul matters/gas etc and shall be disposed off as directed by Engineer-in-Charge. The site shall be left by the contractor in neat and tidy condition before claiming his payment.
Cleaning/dewatering of blockage of any type in WC (Indian/Pedestal) from WC pan to 1st manhole in single/double/triple storied bldg (distance of 1st manhole from outer wall exc. 2 Mtr but n.exc. 5 Mtr including resetting/refitting of access door in soil pipe wherever open without causing any damage to the WC pan 'P' or 'S' trap and pipe including fitting complete all as specified.
Cleaning of blockage of any type in Nahani trap /floor trap provided in bath room, kitchen and indoor water pipe of kitchen sinks and WHB and removing all the sludge and foreign material from the trap and the waste pipe from trap to gully trap surface drain wherever opened or without causing any damage to the trap and pipe including fitting, distance of gully trap from outer wall of bldg up to 2 Mtr complete all as specified.
Excavation in trenches in soft/loose soil not exc. 1.5 M wide and not exc. 1.5 M deep and getting out including forming bottom to required level or slope for laying pipe and concrete bed or for manhole etc not exc. 10 Sqm on plan all as specified and directed by Engineer-in-Charge. (Pipe and concrete bed shall be measured and paid separately).
Excavation in trenches in soft/loose soil not exc. 1.5 m wide and exc 1.5m but not exc 3.0m deep and getting out including forming bottom to required level or slope for laying pipe and concrete bed or for manhole etc not exc. 10 Sqm on plan all as specified and directed by Engineer-in-Charge. (Pipe and concrete bed shall be measured and paid separately).
Excavation in trenches in soft/loose soil not exc. 1.5 m wide and exc 3.0m but not exc 4.5m deep and getting out including forming bottom to required level or slope for laying pipe and concrete bed or for manhole etc not exc. 10 Sqm on plan all as specified and directed by Engineer-in-Charge. (Pipe and concrete bed shall be measured and paid separately).
Returning, filling in soft/loose soil including spreading, leveling and watering well ramming in layers n.exc. 25cm all specified and directed by Engineer-in-Charge.
Removing surplus soil to a distance exc 250m but n.exc. 500m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
Demolition and breaking up drain pipes, set in cement mortar 150mm internal dia (SGSW, AC or reinforced concrete).
Demolition and breaking up drain pipes, set in cement mortar 200mm internal dia (SGSW, AC or reinforced concrete).
M&L cement concrete 1:3:6 mix type C2 (using 40mm graded stone aggregate) as in bed (Thickness of bed below the barrel of pipes 10cm) to drain pipe including packing under and hunching against the sides of pipes after laying in trenches to required slope and tested complete all as specified for 150 mm bore pipe complete all as specified and directed by Engineer-in-Charge.
M&L cement concrete 1:3:6 mix type C2 (using 40mm graded stone aggregate) as in bed (Thickness of bed below the barrel of pipes 15cm) to drain pipe including packing under and hunching against the sides of pipes after laying in trenches to required slope and tested complete all as specified for 200 mm bore pipe complete all as specified and directed by Engineer-in-Charge.
S&F DWCPE (SN8) pipe 150 mm dia (inner) as per IS-16098 (Part-II) laid in trenches or in floor on moorum bed to required shape including all necessary accessories / fitting / jointing / rings, joiting and testing complete all as specified & directed by Engineer-in-charge.
M&L for 150mm dia Reinforced concrete pipe, class NP2, laid in trenches and jointed complete all as specified and directed.
S&F DWCPE (SN8) pipe 200 mm dia (inner) as per IS-16098 (Part-II) laid in trenches or in floor on moorum bed to required shape including all necessary accessories / fitting / jointing / rings, joiting and testing complete all as specified & directed by Engineer-in-charge.
M&L for 200mm dia Reinforced concrete pipe, class NP2, laid in trenches and jointed complete all as specified and directed.
M&L Moorum filling in trenches or pavings, laid in layers not exc 15 cm thick spread, levelled complete all as specified.
S&F 110 mm bore PVC (SWR) pipes single socketd, in any length with rubber ring joints,laid in trenches or in floors including taking down old unserviceable pipe and fittings complete all as specified and directed.
S&F 75 mm bore PVC (SWR) pipes single socketd, in any length with rubber ring joints,laid in trenches or in floors including taking down old unserviceable pipe and fittings complete all as specified and directed.
S&F 75mm bore PVC (SWR) pipes single socketd, in any length with rubber ring joints, fixed to walls including taking down old unserviceable pipe and fittings complete all as specified and directed.
S&F 110mm bore PVC (SWR) pipes single socketd, in any length with rubber ring joints, fixed to walls including taking down old unserviceable pipe and fittings complete all as specified and directed.
S&F 75 mm bore PVC (SWR) bends any radius with oval access door all as directed.
S&F 110 mm bore PVC (SWR) junction single, (Single T) equal or unequal with oval access door all as directed.
S&F epair 75 mm bore PVC (SWR) junction single, (Single T) equal or unequal with oval access door all as directed.
Dismantling of 100mm bore cast iron drain pipe alongwith fittings and accessories jointed in cement mortar and taking out from walls, floors or from trenches, if required complete all as specified and directed.
Dismantling of 75mm bore cast iron drain pipe alongwith fittings and accessories jointed in cement mortar and taking out from walls, floors or from trenches, if required complete all as specified and directed.
S&F100mm dia Cast iron soil, waste and vent pipes, in any length with or without ears with cement joints, laid in trenches or in floors fixed to wall complete all as specified and directed.
S&F 75 mm dia Cast iron soil, waste and vent pipes, in any length with or without ears with cement joints, laid in trenches or in floors fixed to wall complete all as specified and directed.
S&F cast iron 75mm bore bends any radius with oval acess door complete all as specified and directed.
S&F cast iron 75mm bore Branch pieces, single Tee (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval acess door complete all as specified and directed.
S&F cast iron 110mm bore Branch pieces, single Tee (equal or unequal), ordinary or inverted(spigot or socket type) or with parallel branches with oval acess door complete all as specified and directed.
M&L for PCC 1:4:8 type D-2, using 40mm graded stone aggregate in foundation, filling and mass concrete all as specified.
Demolition of brick work of any description and in any position built in cement Mortar and removing rubbish n.exc. 50m all as specified.
Taking down cement plaster including racking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed by Engineer - in - Charge.
M&L for brick work built in cement mortar 1:4 with sub class 'B' bricks old size straight or curved on plan exc. 6m mean radius complete all as specified.
M&L for rendering 15mm thick on fair faces of brick work/internal faces in man holes in CM 1:4 mixed with water proofing compound @ 3% by weight of cement per 50 kg including finishing the surface even and smooth without using extra cement all as specified. (Supply of WPC shall be measured and paid separately).
Supply only integral water proofing compound.
M&L rendering 15mm thick in CM 1:4 on external surface of manholes surfaces finished fair and even without using extra cement complete all as specified and directed.
M&L for PCC type C1 1:3:6 (20 mm grade aggregate) in Copings complete all as specified & directed.
Cutting into existing manholes for connecting new drains, making good for pipes and cutting out existing benching for and forming branch channels(1/2 round or ¾ section) in cement concrete 1:2:4, type B-1 smooth finished and forming benching as required for 150 mm dia SGSW pipe complete all as directed.
Demolition of cement concrete (reinforced) in ground floor/road (below or above ground level) all as specified.
M/L Precast Cement Conctete 1:2:4 type B1, using 20mm graded stone aggregate as in cover slabs for man holes etc set in cement morter 1:6 including necessary form work complete all as specified and directed.
M/L TMT steel bars 6 to 8 mm dia TMT bars over cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking end and binding with and including mild steel wire (annealed ) not less than 0.90 complete all as specified and directed.
S&F 50-70mm thick factory made precast RCC manhole covers including precast frame of any size & shape (Squre / rectangular / circuler), light duty, out side, fixed at site etc 40 x 40 x 6mm angle complete all specified and directed.
M&L for pumping out sewage water from the blocked manhole for any depth for cleaning the existing sewage line through diesel pump set 7.5HP & disposal of sludge as directed.
M&L cleaning/desludging of heavy blockage manhole for any depth by mechanically operated jetting machine with pressure water supply. Note:- The contractor shall remove the sewage / sludge and other foreign material from the site by mechanical equipment etc or by way or other any mean to outside MOD land in covered Vehicls ie Veh required for tpt of foul matters/gas etc and shall be disposed off as directed by Engineer-in-Charge. The site shall be left by the contractor in neat and tidy condition before claiming his payment.
M/s Hoti Lal Contractor
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .