| 1 | L1₹38,393Accepted-AOC B 12 BULANDSHAHAR ROAD GHAZIABAD NEAR RTO OFFICE GHAZIABAD UTTAR PRADESH 201001 UDYAM UP 29 0001058 09AAACK5948C1ZJ B R M MII STATUS AS NOT VERIFIED | GHAZIABAD | UTTAR PRADESH | 201001 | ₹38,393 | L1 | Accepted-AOC L1 |
| 2 | L1₹5.3 LAccepted-AOC | ₹5.3 L | L1 | Accepted-AOC L1 |
| 3 | L1₹7.1 LAccepted-AOC | ₹7.1 L | L1 | Accepted-AOC L1 |
| 4 | L1₹14.1 LAccepted-AOC KHASRA NO 605 612 615 618 PILKHUWA DHOLANA ROAD VILLAGE KHERA PILKHUWA PILKHUWA HAPUR UTTAR PRADESH 245304 UDYAM UP 76 0000242 09AAACU6959R1Z9 R M MII STATUS AS VERIFIED | HAPUR | UTTAR PRADESH | 245304 | ₹14.1 L | L1 | Accepted-AOC L1 |
| 5 | NOT L1Rejected-Finance 17 17 WESTON STREET WESTON STREET KOLKATA WEST BENGAL 700013 | KOLKATA | WEST BENGAL | 700013 | - | NOT L1 | Rejected-Finance NOT L1 |
| Sl No | Description | Qty | Unit | Kisaan Steels Pvt Ltd | Britex Engineering Works | Maass Flange India P Ltd | M.S.FITTINGS MFG. CO. PVT. LTD. | Maxell Forge Industries | Utsah Engineering Private Limited | R D F ENGINEERING PVT LTD |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00SUPPLY OF FLANGES-CS as per Material Requisition | ||||||||||
| 1.00 | WN FLG,CS, 150,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001 | 13 | Nos. | 16,601 ₹19,589.18 | 12,701 ₹14,987.18 | - | 15,769 ₹18,607.42 | 12,285 ₹14,496.30 | 15,093 ₹17,809.74 | 39,000 ₹46,020 |
| 1.00 | WN FLG,CS, 150,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001 | 22 | Nos. | 50,490 ₹59,578.20 | 37,444 ₹44,183.92 | - | 43,736 ₹51,608.48 | 34,100 ₹40,238 | 39,468 ₹46,572.24 | 1,21,000 ₹1.4 L |
| 1.00 | WN FLG,CS, 150,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001 | 11 | Nos. | 40,392 ₹47,662.56 | 28,765 ₹33,942.70 | - | 38,863 ₹45,858.34 | 35,750 ₹42,185 | 32,494 ₹38,342.92 | 71,500 ₹84,370 |
| 1.00 | WN FLG,CS, 150,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001 | 2 | Nos. | 20,196 ₹23,831.28 | 10,390 ₹12,260.20 | - | 13,514 ₹15,946.52 | 12,000 ₹14,160 | 12,660 ₹14,938.80 | 26,000 ₹30,680 |
| 1.00 | WN FLG,CS, 150,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001 | 6 | Nos. | 79,866 ₹94,241.88 | 55,458 ₹65,440.44 | - | 68,910 ₹81,313.80 | 55,200 ₹65,136 | 50,640 ₹59,755.20 | 90,000 ₹1.1 L |
| 1.01 | WN FLG,CS, 150,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001 | 4 | Nos. | 60,588 ₹71,493.84 | 41,184 ₹48,597.12 | - | 52,320 ₹61,737.60 | 48,000 ₹56,640 | 42,200 ₹49,796 | 68,000 ₹80,240 |
| 1.01 | WN FLG,CS (NACE), 150,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005 | 12 | Nos. | 10,476 ₹12,361.68 | 10,596 ₹12,503.28 | - | - | 8,100 ₹9,558 | 10,128 ₹11,951.04 | 30,000 ₹35,400 |
| 1.01 | WN FLG,CS (NACE), 150,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005 | 6 | Nos. | 13,770 ₹16,248.60 | 12,846 ₹15,158.28 | - | - | 9,750 ₹11,505 | 10,764 ₹12,701.52 | 33,000 ₹38,940 |
| 1.01 | WN FLG,CS (NACE), 150,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005 | 2 | Nos. | 50,490 ₹59,578.20 | 73,710 ₹86,977.80 | - | - | 48,600 ₹57,348 | 48,530 ₹57,265.40 | 59,000 ₹69,620 |
Tender Value
Refer Docs
Closing Date
13 Aug 2025, 3:00 pmClosed
Mr. Nilesh Sathe
tkUIPL-Mumbai
SUPPLY OF FLANGES-LOT5 FOR P25 PROJECT AT IOCL PANIPAT REFINERY
2025_REFHQ_185964_1
6745-PPM-000-CA-PI121
Limited
Mechanical - Piping, materials, flanges, valves, seals
70 days
IOCL Panipat Refinery
Please refer Tender documents.
6 documents required · 6 mandatory
Exempted
8 Jan 2026
30 Jul 2025
14 Aug 2025
30 Jul 2025
13 Aug 2025
6 Aug 2025
SUPPLY OF FLANGES-CS as per Material Requisition
WN FLG,CS, 150,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,CS, 150,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,CS, 150,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,CS, 150,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,CS, 150,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,CS, 150,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,CS (NACE), 150,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
WN FLG,CS (NACE), 150,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
WN FLG,CS (NACE), 150,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
WN FLG,CS, 150,0, B16.5, BW ENDS,SCH XS,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,CS, 150,0, B16.5, BW ENDS,SCH XS,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,CS, 150,0, B16.5, BW ENDS,SCH XS,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,CS (NACE+H2), 150,0, B16.5, BW ENDS,SCH XS,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005, 3.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
WN FLG,CS (H2 SER.), 150,0, B16.5, BW ENDS,SCH XS,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
WN FLG,CS (NACE), 150,0, B16.5, BW ENDS,SCH XS,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
WN FLG,CS, 150,0, B16.5, BW ENDS,SCH 160,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,CS (NACE), 150,0, B16.5, BW ENDS,SCH 160,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
WN FLG,CS, 300,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,CS, 300,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,CS, 300,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,CS (NACE+H2), 300,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005, 3.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
WN FLG,CS (H2 SER.), 300,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
WN FLG,CS (H2 SER.), 300,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
WN FLG,CS (H2 SER.), 300,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
WN FLG,CS (H2 SER.), 300,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
WN FLG,CS (NACE), 300,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
WN FLG,CS (NACE), 300,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
WN FLG,CS (NACE), 300,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
WN FLG,CS, 300,0, B16.5, BW ENDS,SCH XS,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,CS, 300,0, B16.5, BW ENDS,SCH XS,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,CS (H2 SER.), 300,0, B16.5, BW ENDS,SCH XS,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
WN FLG,CS (NACE), 300,0, B16.5, BW ENDS,SCH XS,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
WN FLG,CS (NACE), 300,0, B16.5, BW ENDS,SCH XS,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
WN FLG,CS (NACE), 300,0, B16.5, BW ENDS,SCH XS,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
WN FLG,CS (NACE), 300,0, B16.5, BW ENDS,SCH NON-STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
WN FLG,CS, 600,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,CS (NACE), 600,0, B16.5, BW ENDS,SCH STD,RF, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
WN FLG,CS, 600,0, B16.5, BW ENDS,SCH XS,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,CS, 600,0, B16.5, BW ENDS,SCH XS,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,CS (NACE+H2), 600,0, B16.5, BW ENDS,SCH XS,RF, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005, 3.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
WN FLG,CS, 600,0, B16.5, BW ENDS,SCH 160,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,CS (IBR), 150,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.IBR CERTIFICATE IN FORM IIIC REQUIRED
WN FLG,CS (IBR), 150,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.IBR CERTIFICATE IN FORM IIIC REQUIRED
WN FLG,CS (IBR), 150,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.IBR CERTIFICATE IN FORM IIIC REQUIRED
WN FLG,CS (IBR), 150,0, B16.5, BW ENDS,SCH XS,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.IBR CERTIFICATE IN FORM IIIC REQUIRED
WN FLG,CS (IBR), 150,0, B16.5, BW ENDS,SCH XS,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.IBR CERTIFICATE IN FORM IIIC REQUIRED
WN FLG,CS (IBR), 150,0, B16.5, BW ENDS,SCH 160,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.IBR CERTIFICATE IN FORM IIIC REQUIRED
WN FLG,CS (IBR), 150,0, B16.5, BW ENDS,SCH 160,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.IBR CERTIFICATE IN FORM IIIC REQUIRED
WN FLG,CS (IBR), 300,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.IBR CERTIFICATE IN FORM IIIC REQUIRED
WN FLG,CS (IBR), 300,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.IBR CERTIFICATE IN FORM IIIC REQUIRED
WN FLG,CS (IBR), 600,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.IBR CERTIFICATE IN FORM IIIC REQUIRED
WN FLG,CS (IBR), 600,0, B16.5, BW ENDS,SCH XS,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.IBR CERTIFICATE IN FORM IIIC REQUIRED
WN FLG,CS (IBR), 600,0, B16.5, BW ENDS,SCH XS,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.IBR CERTIFICATE IN FORM IIIC REQUIRED
BF,CS, 150,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
BF,CS, 150,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
BF,CS, 150,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
BF,CS, 150,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
BF,CS, 150,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
BF,CS, 150,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
BF,CS, 150,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
BF,CS (NACE+H2), 150,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005, 3.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
BF,CS (NACE), 150,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
BF,CS, 300,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
BF,CS, 300,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
BF,CS, 300,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
BF,CS, 300,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
BF,CS (NACE+H2), 300,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005, 3.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
BF,CS (H2 SER.), 300,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
BF,CS (H2 SER.), 300,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
BF,CS (NACE), 300,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
BF,CS, 600,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
BF,CS (NACE+H2), 600,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005, 3.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
BF,CS (H2 SER.), 600,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
BF,CS (H2 SER.), 600,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
BF,CS (GALV.), 150,0, B16.5, FF, FLANGE A105 (GALV.), ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
BF,CS (GALV.), 150,0, B16.5, FF, FLANGE A105 (GALV.), ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
BF,CS (IBR), 150,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.IBR CERTIFICATE IN FORM IIIC REQUIRED
BF,CS (IBR), 150,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.IBR CERTIFICATE IN FORM IIIC REQUIRED
BF,CS (IBR), 150,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.IBR CERTIFICATE IN FORM IIIC REQUIRED
BF,CS (IBR), 150,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.IBR CERTIFICATE IN FORM IIIC REQUIRED
BF,CS (IBR), 300,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.IBR CERTIFICATE IN FORM IIIC REQUIRED
BF,CS (IBR), 300,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.IBR CERTIFICATE IN FORM IIIC REQUIRED
BF,CS (IBR), 300,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.IBR CERTIFICATE IN FORM IIIC REQUIRED
BF,CS (IBR), 300,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.IBR CERTIFICATE IN FORM IIIC REQUIRED
BF,CS (IBR), 300,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.IBR CERTIFICATE IN FORM IIIC REQUIRED
BF,CS (IBR), 600,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.IBR CERTIFICATE IN FORM IIIC REQUIRED
BF,CS (IBR), 600,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.IBR CERTIFICATE IN FORM IIIC REQUIRED
THREADED FLANGE,CS (GALV.), 150,0, B16.5, SCRD NPT(F) B1.20.1,FF, THREADED FLANGE WITH HUB, FLANGE A105 (GALV.), ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
THREADED FLANGE,CS (GALV.), 150,0, B16.5, SCRD NPT(F) B1.20.1,FF, THREADED FLANGE WITH HUB, FLANGE A105 (GALV.), ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
THREADED FLANGE,CS (GALV.), 150,0, B16.5, SCRD NPT(F) B1.20.1,FF, THREADED FLANGE WITH HUB, FLANGE A105 (GALV.), ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
THREADED FLANGE,CS (GALV.), 150,0, B16.5, SCRD NPT(F) B1.20.1,FF, THREADED FLANGE WITH HUB, FLANGE A105 (GALV.), ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
THREADED FLANGE,CS (GALV.), 150,0, B16.5, SCRD NPT(F) B1.20.1,FF, THREADED FLANGE WITH HUB, FLANGE A105 (GALV.), ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SO FLG,CS, 150,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SO FLG,CS, 150,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SO FLG,CS, 150,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SO FLG,CS, 150,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SO FLG,CS, 150,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SO FLG,CS (GALV.), 150,0, B16.5, FF, FLANGE A105 (GALV.), ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SW FLG,CS, 150,0, B16.5, SW END,SCH XS,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SW FLG,CS, 150,0, B16.5, SW END,SCH 160,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SW FLG,CS, 150,0, B16.5, SW END,SCH 160,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SW FLG,CS, 300,0, B16.5, SW END,SCH XS,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SW FLG,CS, 300,0, B16.5, SW END,SCH XS,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SW FLG,CS, 300,0, B16.5, SW END,SCH XS,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SW FLG,CS (NACE+H2), 300,0, B16.5, SW END,SCH XS,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005, 3.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
SW FLG,CS (H2 SER.), 300,0, B16.5, SW END,SCH XS,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
SW FLG,CS (NACE), 300,0, B16.5, SW END,SCH XS,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
SW FLG,CS (NACE), 300,0, B16.5, SW END,SCH XS,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
SW FLG,CS, 300,0, B16.5, SW END,SCH 160,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SW FLG,CS (H2 SER.), 300,0, B16.5, SW END,SCH 160,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
SW FLG,CS (H2 SER.), 300,0, B16.5, SW END,SCH 160,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
SW FLG,CS (NACE), 300,0, B16.5, SW END,SCH 160,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
SW FLG,CS (NACE), 300,0, B16.5, SW END,SCH 160,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
SW FLG,CS (NACE+H2), 300,0, B16.5, SW END,SCH XXS,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005, 3.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
SW FLG,CS (NACE+H2), 300,0, B16.5, SW END,SCH XXS,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005, 3.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
SW FLG,CS, 600,0, B16.5, SW END,SCH XS,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SW FLG,CS, 600,0, B16.5, SW END,SCH XS,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SW FLG,CS (H2 SER.), 600,0, B16.5, SW END,SCH XS,RF, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
SW FLG,CS (H2 SER.), 600,0, B16.5, SW END,SCH XS,RF, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
SW FLG,CS, 600,0, B16.5, SW END,SCH 160,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SW FLG,CS (NACE+H2), 600,0, B16.5, SW END,SCH 160,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005, 3.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
SW FLG,CS (NACE+H2), 600,0, B16.5, SW END,SCH 160,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005, 3.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
SW FLG,CS (NACE+H2), 600,0, B16.5, SW END,SCH 160,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005, 3.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
SW FLG,CS (H2 SER.), 600,0, B16.5, SW END,SCH 160,RF, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
SW FLG,CS (IBR), 300,0, B16.5, SW END,SCH XS,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.IBR CERTIFICATE IN FORM IIIC REQUIRED
SW FLG,CS (IBR), 300,0, B16.5, SW END,SCH XS,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.IBR CERTIFICATE IN FORM IIIC REQUIRED
SW FLG,CS (IBR), 300,0, B16.5, SW END,SCH 160,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.IBR CERTIFICATE IN FORM IIIC REQUIRED
SW FLG,CS (IBR), 600,0, B16.5, SW END,SCH 160,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.IBR CERTIFICATE IN FORM IIIC REQUIRED
WN FLG,CS,(INT EPOXY CTD), 150,0, B16.5, BW ENDS,SCH STD,RF, FORGED, INTERNAL EPOXY COATED, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.FOR INTERNAL COATING REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0023
WN FLG,CS,(INT EPOXY CTD), 150,0, B16.5, BW ENDS,SCH STD,RF, FORGED, INTERNAL EPOXY COATED, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.FOR INTERNAL COATING REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0023
WN FLG,CS,(INT EPOXY CTD), 150,0, B16.5, BW ENDS,SCH STD,RF, FORGED, INTERNAL EPOXY COATED, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.FOR INTERNAL COATING REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0023
WN FLG,CS,(INT EPOXY CTD), 300,0, B16.5, BW ENDS,SCH STD,RF, FORGED, INTERNAL EPOXY COATED, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.FOR INTERNAL COATING REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0023
WN FLG,CS, 300,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,CS, 600,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,CS (IBR), 600,0, B16.5, BW ENDS,SCH XS,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.IBR CERTIFICATE IN FORM IIIC REQUIRED
BF,CS (NACE), 300,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
SW FLG,CS, 600,0, B16.5, SW END,SCH 160,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,CS, 900,0, B16.5, BW ENDS,SCH XS,RTJ, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SBLD,CS, 150,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
SBLD,CS, 150,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
SBLD,CS, 150,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
SBLD,CS (NACE), 150,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
SBLD,CS (NACE), 150,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
SBLD,CS (NACE), 150,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
SBLD,CS, 300,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
SBLD,CS, 300,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
SBLD,CS, 300,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
SBLD,CS, 300,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
SBLD,CS, 300,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
SBLD,CS, 300,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
SBLD,CS, 300,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
SBLD,CS (NACE+H2), 300,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005, 3.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
SBLD,CS (NACE+H2), 300,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005, 3.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
SBLD,CS (H2 SER.), 300,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
SBLD,CS (H2 SER.), 300,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
SBLD,CS (H2 SER.), 300,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
SBLD,CS (H2 SER.), 300,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
SBLD,CS (H2 SER.), 300,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
SBLD,CS (NACE), 300,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
SBLD,CS (NACE), 300,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
SBLD,CS (NACE), 300,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
SBLD,CS (NACE), 300,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
SBLD,CS, 600,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
SBLD,CS, 600,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
SBLD,CS, 600,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
SBLD,CS, 600,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
SBLD,CS, 600,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
SBLD,CS, 600,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
SBLD,CS (NACE), 600,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
SBLD,CS (GALV.), 150,0, B16.48, FOR FF FLGS,B16.5, FIGURE 8, FLAT FACE, A105 (GALV.), ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
SBLD,CS (IBR), 150,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2.IBR CERTIFICATE IN FORM IIIC REQUIRED
SBLD,CS (IBR), 150,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2.IBR CERTIFICATE IN FORM IIIC REQUIRED
SBLD,CS (IBR), 300,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2.IBR CERTIFICATE IN FORM IIIC REQUIRED
SBLD,CS (IBR), 300,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2.IBR CERTIFICATE IN FORM IIIC REQUIRED
SBLD,CS (IBR), 300,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2.IBR CERTIFICATE IN FORM IIIC REQUIRED
SBLD,CS (IBR), 600,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2.IBR CERTIFICATE IN FORM IIIC REQUIRED
SBLD,CS, 900,0, B16.48, FOR RTJ FLGS,B16.5, FIGURE 8, FEMALE RTJ, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
SBLD,CS (NACE+H2), 150,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005, 3.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
ADAPTOR,FLGD,CS, 150,0, tkIS DRAWING, FLGD,B16.5,RF x FNPT, FORGED, DIM. ACC. TO PIN-LES-PIP-6265, BF/CPL A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
ADAPTOR,FLGD,CS, 300,0, tkIS DRAWING, FLGD,B16.5,RF x FNPT, FORGED, DIM. ACC. TO PIN-LES-PIP-6265, BF/CPL A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
ADAPTOR,FLGD,CS, 300,0, tkIS DRAWING, FLGD,B16.5,RF x FNPT, FORGED, DIM. ACC. TO PIN-LES-PIP-6265, BF/CPL A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
ADAPTOR,FLGD,CS, 300,0, tkIS DRAWING, FLGD,B16.5,RF x FNPT, FORGED, DIM. ACC. TO PIN-LES-PIP-6265, BF/CPL A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
ADAPTOR,FLGD,CS (NACE+H2), 300,0, B16.5,RF, FLGD,B16.5, REDUCING SW FLANGE WITH 1/2", SW BORE.OD,THICKNESS AND PCD, SHALL BE AS PER NOMINAL SIZE, OF FLANGE.THE SW BORE SHALL BE, OF 1/2"., BF/CPL A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005, 3.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
ADAPTOR,FLGD,CS (H2 SER.), 300,0, tkIS DRAWING, FLGD,B16.5,RF x FNPT, FORGED, DIM. ACC. TO PIN-LES-PIP-6265, BF/CPL A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
ADAPTOR,FLGD,CS (H2 SER.), 300,0, tkIS DRAWING, FLGD,B16.5,RF x FNPT, FORGED, DIM. ACC. TO PIN-LES-PIP-6265, BF/CPL A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
ADAPTOR,FLGD,CS (H2 SER.), 300,0, B16.5,RF, FLGD,B16.5, REDUCING SW FLANGE WITH 1/2", SW BORE.OD,THICKNESS AND PCD, SHALL BE AS PER NOMINAL SIZE, OF FLANGE.THE SW BORE SHALL BE, OF 1/2"., BF/CPL A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
ADAPTOR,FLGD,CS (NACE), 300,0, tkIS DRAWING, FLGD,B16.5,RF x FNPT, FORGED, DIM. ACC. TO PIN-LES-PIP-6265, BF/CPL A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
ADAPTOR,FLGD,CS, 600,0, tkIS DRAWING, FLGD,B16.5,RF x FNPT, FORGED, DIM. ACC. TO PIN-LES-PIP-6265, BF/CPL A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
ADAPTOR,FLGD,CS (H2 SER.), 600,0, tkIS DRAWING, FLGD,B16.5,RF x FNPT, FORGED, DIM. ACC. TO PIN-LES-PIP-6265, BF/CPL A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
ADAPTOR,FLGD,CS (H2 SER.), 600,0, B16.5,RF, FLGD,B16.5, REDUCING SW FLANGE WITH 1/2", SW BORE.OD,THICKNESS AND PCD, SHALL BE AS PER NOMINAL SIZE, OF 1/2"., BF/CPL A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
ADAPTOR,FLGD,CS (IBR), 300,0, tkIS DRAWING, FLGD,B16.5,RF x FNPT, FORGED, DIM. ACC. TO PIN-LES-PIP-6265, BF/CPL A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2.IBR CERTIFICATE IN FORM IIIC REQUIRED
ADAPTOR,FLGD,CS (IBR), 300,0, tkIS DRAWING, FLGD,B16.5,RF x FNPT, FORGED, DIM. ACC. TO PIN-LES-PIP-6265, BF/CPL A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2.IBR CERTIFICATE IN FORM IIIC REQUIRED
ADAPTOR,FLGD,CS (IBR), 600,0, B16.5,RF, FLGD,B16.5, REDUCING SW FLANGE WITH 1/2", SW BORE.OD,THICKNESS AND PCD, SHALL BE AS PER NOMINAL SIZE, OF FLANGE.THE SW BORE SHALL BE, OF 1/2"., BF/CPL A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2.IBR CERTIFICATE IN FORM IIIC REQUIRED
BF WITH HOLE,CS, 150,0, B16.5, FLGD,B16.5,RF, FORGED, BLIND FLANGE WITH HOLE TO SUIT, OD OF 2" PIPE, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
BF WITH HOLE,CS, 150,0, B16.5, FLGD,B16.5,RF, FORGED, BLIND FLANGE WITH HOLE TO SUIT, OD OF 2" PIPE, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
BF WITH HOLE,CS, 150,0, B16.5, FLGD,B16.5,RF, FORGED, BLIND FLANGE WITH HOLE TO SUIT, OD OF 2" PIPE, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
BF WITH HOLE,CS (NACE), 150,0, B16.5, FLGD,B16.5,RF, FORGED, BLIND FLANGE WITH HOLE TO SUIT, OD OF 2" PIPE, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
SUPPLY OF FLANGES-AS as per Material Requisition
WN FLG,AS, 300,0, B16.5, BW ENDS,SCH XS,RF, FLANGE A182 Gr.F5, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,AS, 300,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A182 Gr.F9, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,AS, 300,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A182 Gr.F9, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,AS, 300,0, B16.5, BW ENDS,SCH XS,RF, FLANGE A182 Gr.F9, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,AS, 300,0, B16.5, BW ENDS,SCH XS,RF, FLANGE A182 Gr.F9, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,AS (H2 SER.), 300,0, B16.5, BW ENDS,SCH STD,RF, NORMALIZED & TEMPERED, FLANGE A182 Gr.F11 CL.2, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
WN FLG,AS (H2 SER.), 300,0, B16.5, BW ENDS,SCH STD,RF, NORMALIZED & TEMPERED, FLANGE A182 Gr.F11 CL.2, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
WN FLG,AS (H2 SER.), 300,0, B16.5, BW ENDS,SCH XS,RF, NORMALIZED & TEMPERED, FLANGE A182 Gr.F11 CL.2, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
WN FLG,AS (NACE+H2), 600,0, B16.5, BW ENDS,SCH 160,RF, NORMALIZED & TEMPERED, FLANGE A182 Gr.F11 CL.2, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005, 3.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
BF,AS, 300,0, B16.5, RF, FLANGE A182 Gr.F9, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
BF,AS, 300,0, B16.5, RF, FLANGE A182 Gr.F9, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
BF,AS (H2 SER.), 300,0, B16.5, RF, NORMALIZED & TEMPERED, FLANGE A182 Gr.F11 CL.2, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
BF,AS (NACE+H2), 600,0, B16.5, RF, NORMALIZED & TEMPERED, FLANGE A182 Gr.F11 CL.2, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005, 3.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
SW FLG,AS, 300,0, B16.5, SW END,SCH XS,RF, FLANGE A182 Gr.F5, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SW FLG,AS, 300,0, B16.5, SW END,SCH 160,RF, FLANGE A182 Gr.F5, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SW FLG,AS, 300,0, B16.5, SW END,SCH 160,RF, FLANGE A182 Gr.F5, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SW FLG,AS, 300,0, B16.5, SW END,SCH XS,RF, FLANGE A182 Gr.F9, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SW FLG,AS, 300,0, B16.5, SW END,SCH 160,RF, FLANGE A182 Gr.F9, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SW FLG,AS, 300,0, B16.5, SW END,SCH 160,RF, FLANGE A182 Gr.F9, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SW FLG,AS, 600,0, B16.5, SW END,SCH XS,RF, FLANGE A182 Gr.F9, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,AS, 300,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A182 Gr.F5, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
BF,AS (H2 SER.), 300,0, B16.5, RF, NORMALIZED & TEMPERED, FLANGE A182 Gr.F11 CL.2, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
SBLD,AS, 300,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, NORMALIZED AND TEMPERED, A182 Gr.F9, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
SBLD,AS, 300,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, NORMALIZED AND TEMPERED, A182 Gr.F9, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
ADAPTOR,FLGD,AS, 300,0, tkIS DRAWING, FLGD,B16.5,RF x FNPT, FORGED, DIM. ACC. TO PIN-LES-PIP-6265, NORMALIZED & TEMPERED, BF/CPL A182 Gr.F5, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
ADAPTOR,FLGD,AS, 300,0, tkIS DRAWING, FLGD,B16.5,RF x FNPT, FORGED, DIM. ACC. TO PIN-LES-PIP-6265, NORMALISED AND TEMPERED, BF/CPL A182 Gr.F9, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
ADAPTOR,FLGD,AS, 600,0, tkIS DRAWING, FLGD,B16.5,RF x FNPT, FORGED, DIM. ACC. TO PIN-LES-PIP-6265, NORMALISED AND TEMPERED, BF/CPL A182 Gr.F9, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
SUPPLY OF FLANGES-SS as per Material Requisition
WN FLG,SS, 150,0, B16.5, BW ENDS,SCH 40S,RF, FLANGE A182 Gr.F304, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,SS, 150,0, B16.5, BW ENDS,SCH 40S,RF, FLANGE A182 Gr.F304, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,SS, 150,0, B16.5, BW ENDS,SCH 80S,RF, FLANGE A182 Gr.F304, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,SS, 150,0, B16.5, BW ENDS,SCH 80S,RF, FLANGE A182 Gr.F304, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,SS, 300,0, B16.5, BW ENDS,SCH 10S,RF, FLANGE A182 Gr.F304, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,SS, 300,0, B16.5, BW ENDS,SCH 10S,RF, FLANGE A182 Gr.F304, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,SS, 300,0, B16.5, BW ENDS,SCH 40S,RF, FLANGE A182 Gr.F304, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,SS, 600,0, B16.5, BW ENDS,SCH 40S,RF, FLANGE A182 Gr.F304, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,SS,DUAL, 150,0, B16.5, BW ENDS,SCH 10S,RF, FLANGE A182 Gr.F316/316L, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2. SHALL BE DUAL CERTIFIED
WN FLG,SS,DUAL, 150,0, B16.5, BW ENDS,SCH 80S,RF, FLANGE A182 Gr.F316/316L, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2. SHALL BE DUAL CERTIFIED
WN FLG,SS,DUAL, 150,0, B16.5, BW ENDS,SCH 80S,RF, FLANGE A182 Gr.F316/316L, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2. SHALL BE DUAL CERTIFIED
WN FLG,SS,DUAL, 150,0, B16.5, BW ENDS,SCH 80S,RF, FLANGE A182 Gr.F316/316L, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2. SHALL BE DUAL CERTIFIED
WN FLG,SS,DUAL, 600,0, B16.5, BW ENDS,SCH 40S,RF, FLANGE A182 Gr.F316/316L, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2. SHALL BE DUAL CERTIFIED
WN FLG,SS, 150,0, B16.5, BW ENDS,SCH 10S,RF, FLANGE A182 Gr.F316, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,SS, 150,0, B16.5, BW ENDS,SCH 10S,RF, FLANGE A182 Gr.F316, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,SS, 150,0, B16.5, BW ENDS,SCH 40S,RF, FLANGE A182 Gr.F316, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,SS, 150,0, B16.5, BW ENDS,SCH 40S,RF, FLANGE A182 Gr.F316, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,SS, 150,0, B16.5, BW ENDS,SCH 80S,RF, FLANGE A182 Gr.F316, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,SS, 150,0, B16.5, BW ENDS,SCH 80S,RF, FLANGE A182 Gr.F316, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,SS, 300,0, B16.5, BW ENDS,SCH 40S,RF, FLANGE A182 Gr.F316, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,SS, 600,0, B16.5, BW ENDS,SCH 80S,RF, FLANGE A182 Gr.F347H, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,SS, 600,0, B16.5, BW ENDS,SCH 80S,RF, FLANGE A182 Gr.F347H, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
BF,SS,DUAL, 600,0, B16.5, RF, FLANGE A182 Gr.F304/304L, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2. SHALL BE DUAL CERTIFIED
BF,SS, 150,0, B16.5, RF, FLANGE A182 Gr.F304, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
BF,SS, 150,0, B16.5, RF, FLANGE A182 Gr.F304, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
BF,SS, 150,0, B16.5, RF, FLANGE A182 Gr.F304, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
BF,SS, 300,0, B16.5, RF, FLANGE A182 Gr.F304, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
BF,SS, 300,0, B16.5, RF, FLANGE A182 Gr.F304, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
BF,SS,DUAL, 150,0, B16.5, RF, FLANGE A182 Gr.F316/316L, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2. SHALL BE DUAL CERTIFIED
BF,SS, 150,0, B16.5, RF, FLANGE A182 Gr.F316, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
BF,SS, 150,0, B16.5, RF, FLANGE A182 Gr.F316, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
BF,SS, 150,0, B16.5, RF, FLANGE A182 Gr.F316, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
BF,SS, 150,0, B16.5, RF, FLANGE A182 Gr.F316, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
BF,SS, 600,0, B16.5, RF, FLANGE A182 Gr.F347H, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SW FLG,SS,DUAL, 600,0, B16.5, SW END,SCH 80S,RF, FLANGE A182 Gr.F304/304L, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2. SHALL BE DUAL CERTIFIED
SW FLG,SS, 300,0, B16.5, SW END,SCH 40S,RF, FLANGE A182 Gr.F304, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SW FLG,SS, 300,0, B16.5, SW END,SCH 40S,RF, FLANGE A182 Gr.F304, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SW FLG,SS, 300,0, B16.5, SW END,SCH 80S,RF, FLANGE A182 Gr.F304, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SW FLG,SS, 300,0, B16.5, SW END,SCH 80S,RF, FLANGE A182 Gr.F304, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SW FLG,SS,DUAL, 300,0, B16.5, SW END,SCH 80S,RF, FLANGE A182 Gr.F316/316L, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2. SHALL BE DUAL CERTIFIED
SW FLG,SS,DUAL, 300,0, B16.5, SW END,SCH 80S,RF, FLANGE A182 Gr.F316/316L, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2. SHALL BE DUAL CERTIFIED
SW FLG,SS,DUAL, 600,0, B16.5, SW END,SCH 80S,RF, FLANGE A182 Gr.F316/316L, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2. SHALL BE DUAL CERTIFIED
SW FLG,SS, 300,0, B16.5, SW END,SCH 40S,RF, FLANGE A182 Gr.F316, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,SS,DUAL, 150,0, B16.5, BW ENDS,SCH 10S,RF, FLANGE A182 Gr.F316/316L, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2. SHALL BE DUAL CERTIFIED
BF,SS,DUAL, 150,0, B16.5, RF, FLANGE A182 Gr.F316/316L, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2. SHALL BE DUAL CERTIFIED
SW FLG,SS, 600,0, B16.5, SW END,SCH 80S,RF, FLANGE A182 Gr.F304, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SW FLG,SS,DUAL, 300,0, B16.5, SW END,SCH 80S,RF, FLANGE A182 Gr.F316/316L, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2. SHALL BE DUAL CERTIFIED
SBLD,SS,DUAL, 600,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A182 Gr.F304/304L, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. SHALL BE DUAL CERTIFIED
SBLD,SS, 150,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A182 Gr.F304, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
SBLD,SS, 150,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A182 Gr.F304, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
SBLD,SS, 300,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A182 Gr.F304, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
SBLD,SS, 600,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A182 Gr.F304, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
SBLD,SS,DUAL, 150,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A182 Gr.F316/316L, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. SHALL BE DUAL CERTIFIED
SBLD,SS,DUAL, 600,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A182 Gr.F316/316L, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. SHALL BE DUAL CERTIFIED
SBLD,SS, 600,0, B16.48, FOR RF FLGS,B16.5, FIGURE 8, FLAT FACE, A182 Gr.F347H, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
ADAPTOR,FLGD,SS,DUAL, 150,0, tkIS DRAWING, FLGD,B16.5,RF x FNPT, FORGED, DIM. ACC. TO PIN-LES-PIP-6265, FLANGE A182 Gr.F316/316L, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002, 2. SHALL BE DUAL CERTIFIED
ADAPTOR,FLGD,SS, 150,0, tkIS DRAWING, FLGD,B16.5,RF x FNPT, FORGED, DIM. ACC. TO PIN-LES-PIP-6265, BF/CPL A182 Gr.F316, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
ADAPTOR,FLGD,SS, 150,0, tkIS DRAWING, FLGD,B16.5,RF x FNPT, FORGED, DIM. ACC. TO tkUIPL DRG, 6745-PIP-000-TB-0018, (SPECIAL ADAPTER DRAWING IS, DEVELOP FOR COMPONENT COD, WAD420B), BF/CPL A182 Gr.F316, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
ADAPTOR,FLGD,SS, 150,0, tkIS DRAWING, FLGD,B16.5,RF x FNPT, FORGED, DIM. ACC. TO tkUIPL DRG, 6745-PIP-000-TB-00019, (SPECIAL ADAPTER DRAWING IS, DEVELOP FOR COMPONENT CODE, WAD420C), BF/CPL A182 Gr.F316, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
SUPPLY OF FLANGES-LTCS as per Material Requisition
WELDING NECK FLANGE,LTCS, 300,0, B16.5, BW END, SCH STD,RF, FLANGE A350 Gr.LF2 CL.1, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WELDING NECK FLANGE,LTCS, 300,0, B16.5, BW END, SCH STD,RF, FLANGE A350 Gr.LF2 CL.1, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WELDING NECK FLANGE,LTCS, 300,0, B16.5, BW END, SCH STD,RF, FLANGE A350 Gr.LF2 CL.1, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WELDING NECK FLANGE,LTCS, 300,0, B16.5, BW END, SCH XS,RF, FLANGE A350 Gr.LF2 CL.1, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
BLIND FLANGE,LTCS, 300,0, B16.5, RF, FLANGE A350 Gr.LF2 CL.1, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SW FLG,LTCS, 300,0, B16.5, SW END, SCH XS,RF, FLANGE A350 Gr.LF2 CL.1, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SW FLG,LTCS, 300,0, B16.5, SW END, SCH XS,RF, FLANGE A350 Gr.LF2 CL.1, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SW FLG,LTCS, 300,0, B16.5, SW END, SCH 160,RF, FLANGE A350 Gr.LF2 CL.1, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SBLD, LTCS, 300,0, B16.48,FF, FOR RF FLG,B16.5, 125 AARH, FIGURE 8, A350 GR.LF2 CL.1, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0002
FWD143MH+1 1/2"+-+-+-+-+-
FWD143RD+1 1/2"+-+-+-+-+-
Britex Engineering Works
FWD141MH+1"+-+-+-+-+-
FWD141RH+1/2"+-+-+-+-+-
M.S.FITTINGS MFG. CO. PVT. LTD.
Maxell Forge Industries
FWD141MN+1 1/2"+-+-+-+-+-
FWD141SD+3/4"+-+-+-+-+-
FWD141SD+1 1/2"+-+-+-+-+-
FWD143MH+1"+-+-+-+-+-
FWD143RD+3/4"+-+-+-+-+-
Utsah Engineering Private Limited
FWD141MD+1"+-+-+-+-+-
FWD141MN+1"+-+-+-+-+-
FWD141RH+1/2"+-+-+-+-+-
FWD141RH+3/4"+-+-+-+-+-
FWD141RN+1/2"+-+-+-+-+-
FWD141RN+3/4"+-+-+-+-+-
FWD143RD+1/2"+-+-+-+-+-
FWD143RH+1/2"+-+-+-+-+-
FWDZ11M+1"+-+-+-+-+-
FWDZ11M+1 1/2"+-+-+-+-+-
FWDZ11R+3/4"+-+-+-+-+-
FWDZ13R+3/4"+-+-+-+-+-
WAD141DA+2"+-+-+-+-+-
WAD141HA+2"+-+-+-+-+-
WAD143HA+2"+-+-+-+-+-
WADZ13A+2"+-+-+-+-+-
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid