Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SO1 (Works )
ARTC and School 3rd mile Dimapur
PROVN OF REPAIR/MAINTENANCE OF AC, CEILING FANS INSTALLED IN ARTC and S AT DIMAPUR, DIPHU.SHOKHUVI
2021_ARMHA_624653_1
ARTC/DGAR/DPU/73
Open Tender
Electrical Works
Works
180 days
ARTC and School 3rd mile dimapur
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
SO1 Works ARTC and S
Exempted
18 May 2021
27 Mar 2021
10 Apr 2021
27 Mar 2021
9 Apr 2021
27 Mar 2021
27 Mar 2021 - 9 Apr 2021
90 days
Amount
BUILDING REPAIRING WORK
Dismantling & taking down unserviceable sealed unit (Compressor) from existing1.5 Ton /2 Ton Split/window Air Conditioners of any make and replacing with factory repaired and overhauled by original manufacture / authorized dealer ,1.5 / 2 ton cap sealed unit including necessary brazing and cleaning work and charging of refrigerant gas, including provision of new bushes, grommets, sleeves, washers , mounting rubbers , nuts bolts, terminal covers & clips, complete all as specified and directed
Supply and charging of refrigerant gas to Split /window Air Conditioner 2 Ton cap of any make / model/type including detection of leakage, welding and brazing to block the leakage, required pressure testing , vacuumising etc, complete all as specified and directed
Supply and charging of refrigerant gas to Split /window Air Conditioner 1.5 Ton cap of any make / model/type including detection of leakage, welding and brazing to block the leakage, required pressure testing , vacuumising etc, complete all as specified and directed
Replacement of unserviceable blower motor 1/6 Horse power, single phase 230 Volt Make AUE, Usha suitable for 2 Ton Capacity split type Air Conditioner complete all as specified and directed
Replacement of unserviceable fan motor with blade 1/32 Horse Power capacity suitable for water coolers 40/80 Ltr, complete all as specified and directed , Make:- AUE/Crompton/As approved
Replacement of unserviceable swing motor single phase forb1.5 ton 2 ton capacity split type air conditioner completed all as specified and directed
Replacement of unserviceable running capacitor 440V single phase for 1.5 ton 2 ton capacity split type air conditioner completed all as specified and directed
Replacement of unserviceable starting capacitor 220V single phase for 1.5 ton 2 ton capacity split type air conditioner completed all as specified and directed
Replacement of unserviceable contact switch, 220V single phase for 1.5 ton 2 ton capacity split type air conditioner completed all as specified and directed
Copper Tube of ½’’,1/4’’,kiniform,drainage pipe and 3 core cable including labour charge
Servicing of spit type AC s of capacity 1.5 / 2 Ton ,any make by washing the outdoor uint condenser coil with soap water jet followed with clean water jet and indoor uint with the help of blower , wiping and clean the unit dry cloth complete all as specified and directed
Taking out unserviceable PCB unit suitable unit for 1.5/2 Ton capacity for split/ window complete incl repair and replacement of accessories all as per site requirement.
Taking out unserviceable PCB unit suitable unit for 1.5/2 Ton capacity complete incl replacement of new one all as specified and directed by E-I-C
Disconnecting and taking down the complete ceiling fan with down rod from ceiling hook/Fan box any size /make/sweep at any location for carrying out over hauling such as cleaning ,oiling, lubricating, greasing etc and refixing the ceiling fan back on the same location & connecting it properly and complete all as specified and directed. Note : Any worn out/ Defective parts required to be replaced will be measured and paid for separately under relevant item.
Replacement of MS clamp (set of two nos) with nut, bolts and washer, rubber reel, safety pin, complete all as specified and directed.
Replacement of (Bearing No - 6201,6202,6203 ) Ball bearing for 1200/1400 mm sweep ceiling fan of any model complete all as specified and directed. Make: NBC/SKF/HRC
Replacement of existing unserviceable bush with new gun metal bush for any sweep/size/model of ceiling fan complete all as specified and directed
Replacement of capacitor 2.5 Mfd for ceiling fan of any make/model/sweep, complete. Make:- EPCOS/ NICCO/ USHA/ UNISTAR/HAVELLS)
Rewinding the ceiling fan motor of 1200 mm sweep, with super enamelled copper wire of appropriate gauge inc replacement of insulating materials such as laminated elytroid paper, sleeves, necessary varnishing with golden colour varnishing, greasing/oiling of bush and the bearing, replacement of missing/worn out nut, bolt& washer etc and lesting after reassembling the same complete all as specified and directed.
Rewinding the ceiling fan motor of 1400 mm sweep, with super enamelled copper wire of appropriate gauge inc replacement of insulating materials such as laminated elytroid paper, sleeves, necessary varnishing with golden colour varnishing, greasing/oiling of bush and the bearing, replacement of missing/worn out nut, bolt& washer etc and lesting after reassembling the same complete all as specified and directed.
Replacement of PVC canopy of appropriate size suitable, or existing / new down rod complete.
Replacement of down rod and making holes for fixing the nut bolt for 1200/1400 mm ceiling fan as per original pattern and as approved.
Supply and Fix step fan regulator electronic type of switch size suitable for 1200/1400 mm sweep and connecting in circuit complete, Make :SSK. /Anchor/ HAVELLS)
Screw for fan blade as per sample complete all as specified and as directed.
Replacement of ball bearing suitable for 300 mm sweep exhaust fan any modal / Make and type complete all as specified Make : NBC / SKF / TATA/ISIMARKED)
Servicing of package type AC s of capacity 7.5 Ton ,any make by washing the outdoor uint condenser coil with soap water jet followed with clean water jet and indoor uint with the help of blower , wiping and clean the unit dry cloth complete all as specified and directed
Supply and charging of refrigerant gas to Package type Air Conditioner 7.5 Ton cap of any make / model including detection of leakage, welding and brazing to block the leakage, required pressure testing , vacuumisingetc, complete all as specified and directed
Replacement of unserviceable blower motor suitable for 7.5 Ton Capacity split type Air Conditioner complete all as specified and directed. (Make: AUE / Usha)
Taking out unserviceable PCB unit suitable unit for 7.5 Ton capacity complete incl repair and replacement of accessories coded remote all as per site requirement.
Taking out unserviceable PCB unit suitable unit for 7.5 Ton capacity complete incl replacement of new one all as specified and directed by E-I-C
Taking down the Geyser of capacity 25/35 / 50 Ltr including disconnecting of electric / water supply connections from building for repair / replacement of defective components and overhauling / checking, servicing, des calling of inner tank, geyser element, checking of geyser assembly and setting of thermostat range complete and refixing the same after repair and testing including making electectric and water supply connection complete all as specified and directed. Note:- a) All safety precautions for the safety precautions for persons working during removal/fixing back of the Geyser shall be ensured by the contractor . Rates are inclusive of brazing of inner tank of copper for prevention of leakage and replacement of clamps nut bolts gasket set complete. Replacement of defective components, painting, etc., which shall be measured and paid for separately
Supply and Fixing Heating element of capacity 1.50 KW (any type), ISI marked, suitable for geyser of capacity 25Ltr complete all as specified and directed.
Supply and Fixing of Heating element of capacity 2 kW (cup type / triangular / threaded type), ISI marked, suitable for geyser of capacity 50Ltr complete all as specified and directed.
Replacement of neon Indicator lamp of red and green colour lamps suitable for geyser of capacity 25/ 50 Ltr of any type / make complete all as specified and directed
Replacement of Thermostat assembly 16 A,240 AC, ISI marked, suitable for geyser of capacity 25/35/ 50Ltr of any type / make complete all as specified and directed. Make:- Ditz / Universal /TTE/RACOLD/ as apaproved by SO1 (Works)
Replacement of PVC Helical (Hot / Cold) water connection pipe of size 450 mm x 15mm dia with two no of brass nut on each side for geyser complete all as specified and directed/ as per sample)
Replacement of unserviceable swing motor single phase forb1.5 ton 2 ton capacity split type air conditioner completed all as specified and directed
Replacement of unserviceable running capacitor 440V single phase for 1.5 ton 2 ton capacity split type air conditioner completed all as specified and directed
Replacement of unserviceable starting capacitor 220V single phase for 1.5 ton 2 ton capacity split type air conditioner completed all as specified and directed
Replacement of unserviceable contact switch220V single phase for 1.5 ton 2 ton capacity split type air conditioner completed all as specified and directed
Copper Tube of ½’’,1/4’’,kiniform,drainage pipe and 3 core cable including labour charge
Supply and fix Industrial A/C box with code wire of 5mtr length with all accessories as per standard specifications
M/S MAITRA ENTERPRISE
SHUBHAM CENTRE
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .