Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.6 LAccepted-AOC 1442 1 NANADANPURA BABINA CANTT TEHSIL DISTT JHANSI UP | BABINA | JHANSI | UP | L1 | Accepted-AOC Approved by Accepting officer | |
| 2 | L2₹8.3 L+₹53,000 (6.81%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹9.9 L+₹2.2 L (27.7%)Rejected-Finance NEAR SVN UNIVERSITY NARSINGHPUR ROAD SIRONJA SAUGOR MP 470228 | SAUGOR | SAGAR | MP | 470228 | L3 | Rejected-Finance Not Lowest Bidder |
| Sl No | Description | Qty | Unit | M/S JAINENDRA KUMAR JAIN L3 | M/S SHIVA TRADERS L1 | S.R ENGINEER WORKS L2 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation in any type soil in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth (for cable, pole, stay etc) and getting out complete all as specified and directed. | 160 | Cum | 200 ₹32,000 | 160 ₹25,600 Lowest | 180 ₹28,800 |
| 2.00 | Returning filling in including spreading, leveling, watering and well ramming in layer not exc 25 cm complete all as specified and directed. | 75 | Cum | 80 ₹6,000 | 30 ₹2,250 Lowest | 60 ₹4,500 |
| 3.00 | Removing excavated material not exc 50 mtr and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed. | 86 | Cum | 80 ₹6,880 | 30 ₹2,580 Lowest | 50 ₹4,300 |
| 4.00 | Material & labour for providing dry river sand as in sand cushioning to UG cable including punning gently complete all as specified and directed.
Note : Depth after punning shall be measured and paid. | 50 | Cum | 1,050 ₹52,500 | 1,000 ₹50,000 Lowest | 1,500 ₹75,000 |
| 5.00 | Supply and laying Supplying and laying reinforced precast concrete cable cover Class LV, Type I, flat, size 250mm x 150mm x 40mm, laid as cable protection cover incl taking down old unsv bricks complete all as specified and directed. | 3,000 | Each | 35 ₹1,05,000 | 22 ₹66,000 Lowest | 38 ₹1,14,000 |
| 6.00 | Dismantling old unserviceable Steel poles/struts, any size complete all as specified and directed. | 2 | EACH | 500 ₹1,000 | 200 ₹400 Lowest | 500 ₹1,000 |
| 7.00 | Supplying & laying, 10 Sqmm, 2 core cable, XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete including taking down old unserviceable cable complete all as specified and directed. | 250 | RM | 140 ₹35,000 | 130 ₹32,500 Lowest | 140 ₹35,000 |
| 8.00 | Supplying & laying, XLPE insulated PVC inner sheathed, 16 Sqmm, 4 core, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete including taking down old unserviceable cable complete all as specified and directed. | 400 | RM | 225 ₹90,000 | 180 ₹72,000 Lowest | 200 ₹80,000 |
| 9.00 | All as per item No 08 above but cable of size 25 sqmm 3.5 core complete all as specified and directed. | 250 | RM | 240 ₹60,000 Lowest | 300 ₹75,000 | 290 ₹72,500 |
| 10.00 | All as per item No 08 above but cable of size 95 sqmm 3.5 core complete all as specified and directed. | 150 | RM | 730 ₹1,09,500 Lowest | 850 ₹1,27,500 | 850 ₹1,27,500 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
16 Jul 2026, 6:00 pmClosed
Madan Lal Beniwal, IDSE, AEE Civil
AGE I DHANA PIN 470228, DIST SAGAR, MP
REPAIR / REPLACEMENT OF LT ELECTRICAL DISTRIBUTION SYSTEM AND OH LINE AT ZONE A IN MIL STN DHANA.
2026_MES_772997_1
8300/DH/27/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE (I) Dhana
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Assistant Garrison Engineer (I) Dhana
₹20,000
Yes
20 Aug 2026
18 Jun 2026
18 Jul 2026
18 Jun 2026
16 Jul 2026
2 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in any type soil in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth (for cable, pole, stay etc) and getting out complete all as specified and directed. | 160 | Cum | - | - |
| 2 | Returning filling in including spreading, leveling, watering and well ramming in layer not exc 25 cm complete all as specified and directed. | 75 | Cum | - | - |
| 3 | Removing excavated material not exc 50 mtr and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed. | 86 | Cum | - | - |
| 4 | Material & labour for providing dry river sand as in sand cushioning to UG cable including punning gently complete all as specified and directed.
Note : Depth after punning shall be measured and paid. | 50 | Cum | - | - |
| 5 | Supply and laying Supplying and laying reinforced precast concrete cable cover Class LV, Type I, flat, size 250mm x 150mm x 40mm, laid as cable protection cover incl taking down old unsv bricks complete all as specified and directed. | 3,000 | Each | - | - |
| 6 | Dismantling old unserviceable Steel poles/struts, any size complete all as specified and directed. | 2 | EACH | - | - |
| 7 | Supplying & laying, 10 Sqmm, 2 core cable, XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete including taking down old unserviceable cable complete all as specified and directed. | 250 | RM | - | - |
| 8 | Supplying & laying, XLPE insulated PVC inner sheathed, 16 Sqmm, 4 core, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete including taking down old unserviceable cable complete all as specified and directed. | 400 | RM | - | - |
| 9 | All as per item No 08 above but cable of size 25 sqmm 3.5 core complete all as specified and directed. | 250 | RM | - | - |
| 10 | All as per item No 08 above but cable of size 95 sqmm 3.5 core complete all as specified and directed. | 150 | RM | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.70 MB
27TENDERPAGES.pdf
Tender Documents • 3.16 MB
27SoC.pdf
Additional Documents • 0.55 MB
BOQ_865732.xls
BOQ • 0.47 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .