Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.7 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST AND REASONABLE | |
| 2 | L2₹41.7 L+₹4.8 L (13.0%)Rejected-Finance | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹42.3 L+₹5.4 L (14.6%)Rejected-Finance | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹43.8 L+₹6.9 L (18.6%)Rejected-Finance | L4 | Rejected-Finance Not lowest | |
| 5 | L5₹47.3 L+₹10.4 L (28.1%)Rejected-Finance | L5 | Rejected-Finance Not lowest |
Tender Value
₹38.8 L
EMD Value
₹77,600
Closing Date
26 Feb 2024, 6:55 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER
GARRISON ENGINEER JORHAT, MES, JORHAT-785005
SPL REPAIR TO BLDG NO P-31 OF ASC AT BHALUKMARA UNDER GE JORHAT
2024_MES_641229_1
8174/E8
Open Tender
Civil Works
Item Rate
180 days
JORHAT
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GARRISON ENGINEER Jorhat
₹77,600
Yes
18 Mar 2024
7 Feb 2024
27 Feb 2024
8 Feb 2024
26 Feb 2024
20 Feb 2024
8 Feb 2024 - 14 Feb 2024
Amount
NOTES :The bidders/contractors are advised to read tender document & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc. or for shafts, wells, cess pits, manholes, pier holes etc. not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out as in soft/loose soil.
Removing excavated material (soil) not exceeding 50 m and depositing where directed at a level n. exc. 1.50 m above the starting point.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm as in soft/loose soil.
Dismantling plain/corrugated steel sheeting, any guage, thickness including eves gutter / rain water pipe complete & removal all as specified
Dismantling steel work including gates, rafter, purlin, roof truss etc complete all as specified & as directed.
Material and labour for Rolled mild steel in roof truss (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including cleats Fe-410 W (Gde E-250) Quality-B including one shop coat of zinc chromate primer after preparation of surface complete all as specified and as directed.
Supply and fixing of pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick and an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Supply and fixing of pre-painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in ridges, tips, valley, gutters, length & girth as fixed with nail or screws complete all as specified and as directed.
Supply and fixing of plain, aluminium sheeting of Alloy 31000 H4 of 0.56 mm thick in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed) complete all as specified.
Rendering 15 mm in Cement Mortar 1:6 on fair faces of brick work or concrete surfaces finished even smooth without using extra cement to the plastered surface complete all as specified and as directed.
Material and labour for Rendering 15mm thick plaster in Cement Mortar (1:4) on fair faces of brick or concrete surface of wall and finished even and smooth without using extra cement, with water proofing treatment. Note:- Water proofing compound shall be measure and paid separately
Supply only integral liquid water proofing compound complete all as specified and directed.
Taking down cement plaster from brick or concrete surfaces of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as directed.
Material and labour for Preparation of new plaster wall surface and applying two coats of 1st quality acrylic washable distemper (ready mixed) having VOC content less than 50 gms/litre of required colour shade and as per manufacturer’s specification over a coat of primer over a coat of 1.5 mm thick cement base wall putty complete all as specified and directed.
Material and labour for complete removal of existing finishing of internal wall surface of building/structure by mechanical appliance and preparation of old surfaces and applying two coats of two coats plastic emulsion paint of required colour shade and as per manufacturer’s specification over a coat of primer o complete all as specified and directed.
Material and labour for preparation of new surfaces and and applying 2 coats of cement based paint over a coat of alkali based primer complete all as specified and directed.
Material and labour for complete removal of existing finishing of internal wall surface of building/structure by mechanical appliance and applying 2 coats of cement based paint over a coat of alkali based primer of any description over 10 cm girth or width complete all as specified and directed.
Demolition of cement concrete ( un-reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) and removing debris to a distance n.exc. 50 m etc complete all as specified and as directed.
Material and labour for 40 mm thick plain cement concrete M-15(Nominal Mix) using 20 mm graded stone aggregate as in floor, finished even and smooth with using extra cement complete all as specified and as directed.
Material and labour for Plain Cement Concrete M-15(Nominal Mix) using 20 mm gaded stone aggregate as in Surface channel and drain
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc.
Taking down chowkats/frames with shutters (without taking off shutters from the frame) etc. not exceeding 1.50 Sqm each complete all as specified and as directed.
Materials and labour for Mild Steel framed work such as guard bars, grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe-290(Gde E-165) complete all as specified and as directedincluding taking dwon old one complete all as specified and as directed.
Supply and fixing of steel ventilator with top hung shutters including hinges with steel handle and steel peg stay complete without gauged bars, dovetailed or welded complete all as specified and as directed
Supply and fixing of steel windows with side hung shutters including hinges projecting type with steel handle and steel peg stay complete with gauged bars, dovetailed or welded complete all as specified and as directed
Supply and fixing of steel windows with side hung shutters including hinges box type with steel handle and steel peg stay complete without gauged bars, dovetailed or welded complete all as specified and as directed
Supply and fixing of Steel rolling shutters, with ball bearing, as specified including top cover and anchoring rod, hasp & staple and one shop coat of primer gear operated type(mechanical type) with bevel gear box and crank handle, thickness of lath 1.25 mm including taking dwon old one complete all as specified and as directed
Supply and fixing of Safety lever locks mild steel witikh 4 levers for rolling shutters complete all as specified and as directed
Supply and fixing of sheet glass 4 mm thick ordinary quality fixed to aluminum door & window in squares in each pane of required size complete all as specified and as directed.
Supply and fixing in repair of sheet glass 4 mm thick ordinary quality fixed to aluminum door & window in squares in each pane of required size complete all as specified and as directed.
Material and labour for Stainless steel wire cloth, 0.43 mm nominal dia of wire and avergae width of aperture 1.00 mm and fixed with stainless steel wire staples complete all as specified and directed.
Material and labour as in repair for Stainless steel wire cloth, 0.43 mm nominal dia of wire and avergae width of aperture 1.00 mm and fixed with stainless steel wire staples complete all as specified and directed.
Material and labour for preparation of new steel surface and applying two coats of synthetic enamel paint over a coat of red oxide primer on new steel and iron surfaces of any description over exceeding 10 cm in width or girth complete all as specified and as directed..
Supply and fixing of uPVC of type-B for use in soil and waste discharge systems, single socket, 110 mm bore in any length including rubber ring joints and fixed to walls with clips and other standard material and all as specified in IS 13592and including taking down old pipe complete all as specified and directed.
Supply and fixing of Unplasticized (uPVC )bend for 110 mm bore uPVC pipe complete all as specified and directed.
Subtotal of Sch A part-I
SCHEDULE 'A' PART - II FOR E/M PORTION (Sl No __ to ____)
Taking down carefully unserviceable copper / aluminium point wiring (light, fan, bell socket or power) including all fittings such as switches, socket, ceiling roses , regulators and switch boxes etc complete and making good the disturbed surfaces complete all as specified and as directed.
Material and labour for point wiring with 1.5 Sq. mm (nominal area) PVC insulated and sheathed single core FRLSHcopper cable 1100 volts grade with stranded copper conductor in and including PVC cassing caping with double lock (heavy grade) and conduit accessories alongwith continuous earth wire 1.5 Sq mm PVC insulated and sheathed single core FRLSH cable 1100 volts grade with stranded copper conductor and connected to common earth dolly complete for one light/fan point controlled by one switch complete all as specified and as directed. Note:-Flush steel terminal box, inner plate and front plates shall be measured and paid seperately.
Material and labour for Point wiring with 1.5 Sq. mm (nominal area) PVC insulated and sheathed single core FRLSHcopper cable 1100 volts grade with stranded copper conductor in and including PVC cassing caping with double lock (heavy grade) and conduit accessories alongwith continuous earth wire 1.5 Sq mm PVC insulated and sheathed single core FRLSH cable 1100 volts grade with stranded copper conductor and connected to common earth dolly complete for modular one socket outlet 5 pin 6 amps on independent board complete all as specified and as directed.
Material and labour for Point wiring with 1.5 Sq. mm (nominal area) PVC insulated and sheathed single core FRLSH copper cable 1100 volts grade with stranded copper conductor in and including PVC cassing caping with double lock (heavy grade) and conduit accessories alongwith continuous earth wire 1.5 Sq mm PVC insulated and sheathed single core FRLSH cable 1100 volts grade with stranded copper conductor and connected to common earth dolly for one 5 amps socket outlet on same board with other switch complete all as specified and as directed.
Materials and Labour for Point wiring with4.00 Sq. mm (nominal area) PVC insulated and sheathed single core FRLSHcopper cable 1100 volts grade with stranded copper conductor in and including PVC cassing caping with double lock (heavy grade) and conduit accessories alongwith continuous earth wire 4.00 Sq mm PVC insulated and sheathed single core FRLSH cable 1100 volts grade with stranded copper conductor and connected to common earth dolly complete for modular one socket outlet 5 pin 16 amps on independent board complete all as specified and as directed. NOTES FOR ITEM NO 123 to 126- Flush steel terminal box, inner plate and front plates shall be measured and paid seperately.
Material and labour for Metal flush box 2 module complete all as specified and as directed.
Material and labour for Metal flush box 3 module complete all as specified and as directed.
Material and labour for Metal flush box 4 module complete all as specified and as directed.
Material and labour for Metal flush box 6 module complete all as specified and as directed.
Material and labour for White cover plate with frame (both ineer plate & outer plate cover) ,2 module complete all as specified and as directed.
Material and labour for White cover plate with frame (both ineer plate & outer plate cover) ,3 module complete all as specified and as directed.
Material and labour for White cover plate with frame (both ineer plate & outer plate cover) , 4 module complete all as specified and as directed.
Material and labour for White cover plate with frame (both ineer plate & outer plate cover) , 6 module complete all as specified and as directed.
Material and labour for Modular switch 6 Amp single pole one way complete all as specified and as directed.
Material and labour for Modular switch 16 Amp single pole one way complete all as specified and as directed.
Material and labour for Modular socket 16/6 Amp 3 pin combined shattered complete all as specified and as directed.
Material and labour for Modular socket 6 Amp 2/3 pin combined shattered complete all as specified and as directed.
Material and labour for Electronic type fan regulator step type 120 watt, 230 volt complete all as specified and as directed.
Supply and fixing ceiling rose surface bakelite 65x50mm three terminals complete all as specified and as directed.
Supply and fixing of LED surface/ceiling mounting(suspended from ceiling) box type light fitting 20Watt with LED Lamp , drive and made of epoxy powder coated extruded aluminium channel housing with high quality polycarbonate opal diffuser cover & high power LED’s as light source with 120 Lumen per watt (Minimum) and including all other standard accessories as per manufacture instructions ,internally pre-wired including connecting up three core1.00sq. mm copper conductor flexible wire/cable complete all as specified. Make : Model No CCS-100-20-65-HL2-DP-NWH of Crompton/ BCLAB 20W WH LED P of Bajaj or equivalent model of make list as given in PS as approved by GE.
Supply & Fixing of LED street light fitting ( Building Security light) of 35Watt with LED lamp’s & driver and made of pressure die-cast aluminum housing, IP 65/IP 66 road way luminaries with UV stabilized polycarbonate cover or toughen glass cover & high power LED’s as light source with 110 Lumen per watt and electronic driver with efficiency > 85% . The light fitting shall be fixed on wall/pole with and including 25 mm dia( or higher size as per manufacturers recommendation) light grade GI pipe (bend to shape or as per manufacturers recommendation ) bracket 1.5 mtr long complete with MS flat iron clamp (clamps shall be 40 x 5 mm MS flat) nuts, bolts & washers including painting the clamps with two coat of aluminium paint over a coat of red oxide primer and including taking up old light fitting complete all as specified and as directed Make:- Model No- TRP-400-35-57-SL-LM-NSR of Crompton Greave/ NXT P 36L WH CR PC SD of Bajaj or equivalent model of make list as given in PS. Notes : GI pipe bracket and clamps shall be deem to be included above quoted rate..
Supply and fixing of sheet metal enclosure for MCBs to be used singal pole & nutral double door 8 Way 200 Amps rated busbar and including fixed with 25mm x 6 mm mild steel clamp of suitable length complete all as specified and as directed.
Supply and fixing of MCB SP of rating 6 to 32 Amps 240 V complete all as specified and as directed.
Supply and fixing MCB DP 40 to 63 amps 240 volts 10KA breaking capacity complete all as specified and as directed.
Supply and fixing of sub main wiring with two single core 6.0sqmm (nominal area) PVC insulated copper conductor FRLSH, multi stranded, unsheathed 1100 volts grade IS-694 marked in PVC double lock casing caping and accessories accessories including one single core 6.0 sqmm copper conductor cable FRLSH as earth wire and including taking out old sub-main wiring complete all as specified and as directed. NOTE:- (a) All runs of copper conductor and one run of conduit shall be measured as one run length.
Material and labour for Sand cushioning to the full width of trenches for protection of cables including punning down complete all as specified and as directed. Note :- Thickness of sand cushioning shall be the thickness after punning down.
Material and labour for laying of Class designation 75 bricks, old size, flat, common clay laid in trenches across the trench as cable protection complete all as specified and as directed.
Material and labour for laying of LT XLPE insulated armoured heavy duty cable 1100 volt grade ISI marked with alumimium conductor multi strand cross sectional area 35 Sqmm x 3 ½ Core complete all as specified and as directed.
Material and labour for laying of LT XLPE insulated armoured heavy duty cable 1100 volt grade ISI marked with alumimium conductor multi strand cross sectional area 10 Sqmm x 4 Core complete all as specified and as directed.
Material and labour for laying of 40mm bore galvanised steel tubes, light grade for cable protection complete all as specified and as directed.
Material & Labour for earthing with galvanised steel earth plate electrode of size 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron using GI 4 mm dia wire as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI medium grade earth lead protection pipe, CI frame and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternatee layer complete all as specified and directed .
Material & Labour for earthing with galvanised steel earth plate electrode of size 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI strip 25x4mm as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI medium grade earth lead protection pipe, CI frame and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternatee layer and including taking down existing one complete all as specified and directed .
Supply, design, installation, testing and commissioning of factory made powder coated (CPRI approved) outdoor type, dust & vermin proof feeder pillar box made out of 3.15mm CRCA steel sheet of suitable size and angle iron 40 mm x 40mm x 6 mm , powder coated over one coat of red oxide primer suitably grouted in PCC-M10 using 20 mm graded stone aggregate including aluminum bus bar, internal wiring with PVC insulated single core cables of copper conductor of suitable size duly numbered with tags for the circuits with hinged double door shutters (front & rear), cubical type locking arrangement and slanted roof. The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 415 Volt, 3 phase, 50 Hz supply system. The panel board shall comprise of following items & all specified in SSR Part-I clause no 19.21 and all as shown on drawing . INCOMING :-
Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs ₹ ___________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ.
MS J B CONSTRUCTION AND CO
M/S GOPAL ROY AND CO
SUBHAS CONSTRUCTIONS
RAJGURU & CO
M/S RK SAHA AND CO
M/S DILIP GOSWAMI
M/S D J ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .