Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹7.8 L
EMD Value
₹15,650
Closing Date
17 Dec 2019, 3:30 pmClosed
Sr. Executive Engineer(EW)
OFFICE OF THE Sr. Executive Engineer(EW), ESTATE ( EM), Head Office, 1st Floor, Old Buildin,
Electrical works associated with Mortuary for Dr. B.C.Roy Hospital of Medical Science and Research at IIT KGP
2019_IITKG_516000_1
IIT/E/EM/T/59/2019-20
Open Tender
Electrical Works
Item Rate
90 days
IIT Kharagpur
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹15,650
Yes
ESTATE ( EM), Head Office, 1st Floor, Old Buildin,
3 Jan 2020
4 Nov 2019
18 Dec 2019
4 Nov 2019
17 Dec 2019
4 Nov 2019
4 Dec 2019
Amount
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 Sqmm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Make: Modular Switch- Crabtree(Athena)/Legrand (Myrius)/ MK (Wraparound Plus), Cable-1.1 kV grade FRLS Type Insulated copper conductor: Havells/Finolex/RR Kabel/KEI/Polycab, PVC Conduit - Precission (MMS) /Presto Plast/Finolex/Polycab or eqivalent approved by EIC.
Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess, including providing and fixing 6pin 5/6 amps modular socket outlet and 10 amps modular switch, connection etc. as required. Make: Switch, socket, Modular box and Plate: Crabtree (Athena)/ Legrand ( Myrius)/MK(Wraparound Plus) or eqivalent approved by EIC.
Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess, including providing and fixing 6pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. Make: Switch, socket, Modular box and Plate: Crabtree (Athena)/ Legrand ( Myrius)/MK(Wraparound Plus) or eqivalent approved by EIC.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade upto 35 sq. mm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. Crabtree (Athena)/ Legrand ( Myrius)/MK (Wraparound Plus), or eqivalent approved by EIC.
Supplying and fixing of Single pole( 6 to 32Amps) rating, 240 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make:Legrand/Hager/ Siemens or eqivalent approved by EIC.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. Make: Cable-Havells/Finolex/RR Kabel, PVC Conduit - Precission (MMS) /Presto Plast/Finolex/Polycab/KEI/Polycab or eqivalent approved by EIC.
a) 2 X 1.5 sq.mm. + 1 X 1.5 sq.mm. earth wire
b) 2 X 2.5 sq.mm. + 1 X 2.5 sq.mm. earth wire
c) 2 X 4 sq.mm. + 1 X 4 sq.mm. earth wire
d) 4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Earthing with G.I. earth pipe (Bansal/TATA medium ) 4.5 metre long, 40mm dia including accessoires, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required with extra treatment of salt and charcoal.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground / wall as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)
Supplying and laying 6 SWG GI wire at 0.50 metre below ground level/wall for conductor earth electrode, including connection/termination with GI thimble etc. as required.
Supply and fixing of 15Watt, 5000K, lumen output>100Lumens/Watt, p.f>0.9, high power LED die-cast , acrylic cover outdoor luminaire with 5 years warrenty on existing GI bracket with proper connection. (Make:Philips/Havells/ Wipro/Crompton/Bajaj) or eqivalent approved by EIC.
Supply and fixing of 40mm dia. 1mr. Long GI (TATA/BANSAL Medium) fabricated wall bracket with suitable size GI sadle, fastner etc.
Supply and fixing of 4ft, <= 18Watt, 6500K, lumen output>=2100Lumen, P.F>0.9, high power retrofit LED tube with 5 years warrenty (Make:Philips/Havells/ Wipro) or eqivalent approved by EIC.
Supply and fixing Regal Batten for LED luminaire in item no.13 (Make:Philips/Havells/ Wipro) or eqivalent approved by EIC.
Supply of 1200 mm sweep 5 star rated BLDC energy efficient ceiling fan with cu wiring having 3 nos blades, down rod, canopies, shackles, safety rope, suitable for 230 V, 50 HZ with power factor > 0.98, service ratio >7.5, air delivery > 215 CMM, Power consumption - less than 30w, THD =<10% with speed control by electronic regulator.Guarantee: Five years.Colour-White. Make: Havells/Atomberg/ Orient/ Crompton / Equivalent approved by EIC
Supply and erection of 9 mtr Hot deep galvanized street light octagonal pole( base and top dia - minimum of 150 mm and 70 mm respectively, 3 mm thickness, material construction - As per IS 5986, GI standard- as per IS 4759, Thickness of Galvanization -76 micron avarage, Base Plate - as per IS 2062) with 1500 mm single arm with inside prewired connector box and single phase mcb with foundation bolt. Make: Bajaj/ Utkarsh India/ J.K.Pole /eqivalent approved by EIC.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade above 35 sq. mm and upto 95 sq. mm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Providing, laying and fixing 80 mm dia G.I. pipe (medium class) in ground or through horizontal boring/horizontal trenchless drilling for crossing of Road (750 mm or more depth below ground) complete with G.I. fittings including trenching (750 mm deep) and re-filling etc. as required.Make: TATA/ JINDAL/SAIL or eqivalent approved by EIC.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade above 35 sq. mm and upto 95 sq. mm in the existing RCC/ HUME/ METAL pipe as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade above 35 sq. mm and upto 95 sq. mm on wall surface as required.
Supply and fixing Low noise Plastic body Exhaust fan 250 mm sweep,1280 rpm, 817 CMH as per IS 2312, 1967with double ball bearing with Guard with making hole arrangement in wall. Make:USHA/ CG/EPC/ or equivalent approved by EIC
Supply and fixing Low noise metal body Exhaust fan 300 mm sweep,1400 rpm, Air delivery-1710 M3/Min as per IS 2312, 1967with double ball bearing with Guard with making hole arrangement in wall. Make:USHA/ CG/EPC/ or equivalent approved by EIC
Supply of 3.5C x 50 sqmm Power Cables, Solid Aluminum stranded conductor, XLPE Insul ,cores laid up, PVC inner sheathed, Armoured , balance all galvanized steel strip, extruded PVC Type ST2 sheathed, 1100V grade as per IS 7908(Part 1) 1988. Cable Make: Havells/Finolex/RR kabel/KEI/Polycab/RPG or equivalent approved by EIC
Supply and installation of pole mounted LED Street Light fixture of 90W, lumen output >120, equivalent to Philips Model No- BRP 410 LED 092 CW HE NR FG S2 PSU GR in Street Light Pole with all necessary connection with mcb and wiring including 5 years warrenty on LED Light fitting. Make: Philips/ Wipro/ LT/ eqivalent approved by EIC.
Supply and installation of 4 pole 100 A, 18 KA MCCB in the existing VTPN with all complete wiring. Make: Legrand/Hager/ Siemens or eqivalent approved by EIC.
Supplying and fixing of 4 way, double door, 3 pole and neutral, sheet steel, VTPN distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, incomer kit, interconnections, power painted including earthing etc as required suitable for MCCB incomer and MCB outgoing . Make:Legrand/Hager/ Siemens/ Havells or eqivalent approved by EIC.
Supplying and making end termination with brass compression gland and aluminium lugs for 3.5 x 50 Sqmm of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Make: Dowell's / Comet / Equivalent approved by EIC
Supply of 4C x 6 sqmm Power Cables, Solid Aluminum stranded conductor, XLPE Insul ,cores laid up, PVC inner sheathed, Armoured , balance all galvanized steel strip, extruded PVC Type ST2 sheathed, 1100V grade as per IS 7908(Part 1) 1988. Cable Make: Havells/Finolex/RR kabel/KEI/Polycab/RPG or equivalent approved by EIC
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade upto 35 sq. mm in the existing RCC/ HUME/ METAL pipe as required.
Supplying and making end termination with cast resin compound including aluminium lugs and other jointing materials for 4C x 6 Sqmm of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
Erection of RCC/ PCC/Steel pole of 9 mtr length in brick ballast and ramming the foundation, finishing with 150mm thick cement concrete (1:3:6) layer on top with including excavation and refilling etc as required.
Supply and installation of 3 pole 63 A, 10 KA MCB in the existing VTPN with all complete wiring. Make: Legrand/Hager/ Siemens or eqivalent approved by EIC.
Supply and installation of 4 pole 63 A, 10 KA MCB in the existing ETPN with all complete wiring Make: Legrand/Hager/ Siemens or eqivalent approved by EIC.
Supplying and fixing following 4 way ( 4+12, double door), horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) MAke:Legrand /Hager/ABB/Siemens or eqivalent approved by EIC.
Spike Earthing: The earthing rod should be 1853 mm (i.e. 25 + 1752 + 76) long fabricated from 20 mm dia M.S. Rod, the bottom of which to be made cut of the same rod in the shape of a cone – 76 mm long and the forged head made out of the same rod with 30 mm (dia) = 25 mm (height). The earthing arrangements should consist of G.I. Bolt/nut and washers. Make: West Bengal State Electricity board approved make/ ISI Marked
POOJA ENGINEERING WORKS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .