DIG (Engineer) Dte. CRPF
Works Directorate, CRPF, East Block-7, Level-3, RK Puram, Sector-1, New Delhi-110066
Operation and Maintenance contract for DG sets (62.5 KVA-02 nos, 200 KVA-02 nos, and 125 KVA- 01 nos) of various capacity with main LT panels cum AMF panels
2024_CRPF_841317_1
Operation and Maintenance contract for DG sets
Open Tender
Electrical Works
Works
GC, CRPF Greater Noida
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹24,011
17 Mar 2025
24 Dec 2024
3 Jan 2025
24 Dec 2024
1 Jan 2025
24 Dec 2024
24 Dec 2024 - 31 Dec 2024
Amount
Operator for operation and Maintenance
Operator/Skilled labour-01 no (Electrician/Mechanic) for one shift (9am -5pm ) or as per direction of Engineer-in-charge.
Services and maintenance
Carrying out Services and maintenance of 02 nos DG set 62.5/63 KVA Diesel engine with AMF panel of any make to ensure smooth running of DG set for 30 mins on load. Checking for abnormal sound and leakages, carry out visual inspection of all moving parts, oil levels, oil filters, fuel filters, air filters and clean them properly, rectify the minor leakages if any. Inspect alternator, stator and rotor for normal speed & proper frequency, examine battery charging with monitoring system and recording voltages, checking battery cells gravity and topping up with distilled water, checking V belts with necessary adjustment, checking and retightening of nut bolts including coupling bolts of engine and alternator, checking & cleaning of radiator and leakage testing checking of radiator & fuel supply hose pipes, checking of AVR, excitation diodes, its connections confirming proper output voltage. checking & resetting of valve tappets, Cleaning of DG set internally using blower, cleaning radiator and Submit the servicing report to engineer in charge. (i) Topping up new lubricating oil 15W/40 or as specified grade of approved make as per IS 13656 : 2014 (ii) Topping up new glycol based coolant or as specified 50/50 with operating range from 118°C to -37°C of approved make as per direction of engineer in charge. (iii) Supplying and erecting lub oil filter element along with sealing rings, gasket etc complete suitable for DG Set as per direction of engineer in charge. (iv) Supplying and erecting fuel filter along with sealing rings, gasket, primary filter and water separator etc. complete suitable for DG Set as per direction of engineer in charge. (v) Supplying and erecting Air cleaner/Air filter element suitable for DG set as per direction of engineer in charge. (Note :-Servicing of generators shall be done quarterly or running/completion of 500 hrs., whichever earlier or as desired by Engineer-in-charge and maintenance shall be done as and when required)
Carrying out Services and maintenance of 01 no DG set 125 KVA Diesel engine with/without AMF panel of any make to ensure smooth running of DG set for 30 mins on load. Checking for abnormal sound and leakages, carry out visual inspection of all moving parts, oil levels, oil filters, fuel filters, air filters and clean them properly, rectify the minor leakages if any. Inspect alternator, stator and rotor for normal speed & proper frequency, examine battery charging with monitoring system and recording voltages, checking battery cells gravity and topping up with distilled water, checking V belts with necessary adjustment, checking and retightening of nut bolts including coupling bolts of engine and alternator, checking & cleaning of radiator and leakage testing checking of radiator & fuel supply hose pipes, checking of AVR, excitation diodes, its connections confirming proper output voltage. checking & resetting of valve tappets, Cleaning of DG set internally using blower, cleaning radiator and Submit the servicing report to engineer in charge. (i) Topping up new lubricating oil 15W/40 or as specified grade of approved make as per IS 13656 : 2014 (ii) Topping up new glycol based coolant or as specified 50/50 with operating range from 118°C to -37°C of approved make as per direction of engineer in charge. (iii) Supplying and erecting lub oil filter element along with sealing rings, gasket etc complete suitable for DG Set as per direction of engineer in charge. (iv) Supplying and erecting fuel filter along with sealing rings, gasket, primary filter and water separator etc. complete suitable for DG Set as per direction of engineer in charge. (v) Supplying and erecting Air cleaner/Air filter element suitable for DG set as per direction of engineer in charge. (Note :-Servicing of generators shall be done quarterly or running/completion of 500 hrs., whichever earlier or as desired by Engineer-in-charge and maintenance will be done as and when required)
Carrying out Services and maintenance of 02 nos DG set 200 KVA Diesel engine with AMF panel of any make to ensure smooth running of DG set for 30 mins on load. Checking for abnormal sound and leakages, carry out visual inspection of all moving parts, oil levels, oil filters, fuel filters, air filters and clean them properly, rectify the minor leakages if any. Inspect alternator, stator and rotor for normal speed & proper frequency, examine battery charging with monitoring system and recording voltages, checking battery cells gravity and topping up with distilled water, checking V belts with necessary adjustment, checking and retightening of nut bolts including coupling bolts of engine and alternator, checking & cleaning of radiator and leakage testing checking of radiator & fuel supply hose pipes, checking of AVR, excitation diodes, its connections confirming proper output voltage. checking & resetting of valve tappets, Cleaning of DG set internally using blower, cleaning radiator and Submit the servicing report to engineer in charge. (i) Topping up new lubricating oil 15W/40 or as specified grade of approved make as per IS 13656 : 2014 (ii) Topping up new glycol based coolant or as specified 50/50 with operating range from 118°C to -37°C of approved make as per direction of engineer in charge. (iii) Supplying and erecting lub oil filter element along with sealing rings, gasket etc complete suitable for DG Set as per direction of engineer in charge. (iv) Supplying and erecting fuel filter along with sealing rings, gasket, primary filter and water separator etc. complete suitable for DG Set as per direction of engineer in charge. (v) Supplying and erecting Air cleaner/Air filter element suitable for DG set as per direction of engineer in charge. (Note :-Servicing of generators shall be done quarterly or running/completion of 500 hrs., whichever earlier or as desired by Engineer-in-charge and maintenance shall be done as and when required)
Replacement of Damaged Fittings
Replacement of Fuel tank of 01 No. 200 KVA DG Set at Adm Block.
Installation/replacement of UPS Battery system (200 KVA DG Set) at Adm Block Electric control panel.
Body Painting of 125 KVA DG Set at STP-1.
Replacement of Base frame of 125 KVA DG Set at STP-1.
NOTE:- All items to be used in this work should be genuine spare parts of OEM. In case of any discrapency decision of Engineer-in-charge shall be final and abiding.
MAHI TRADERS (BID ID -3147584)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .