| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹13.9 CrAccepted-AOC A 153 HQ CE EC KOLKATA LEKHAPANI POST TINSUKIA DIST ASSAM STATE | ₹13.9 Cr | 1 | Accepted-AOC Being L1 bidder |
| 2 | 2₹15.2 CrRejected-Finance | ₹15.2 Cr | 2 | Rejected-Finance Being second lowest bidder L2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical EMD not submitted by the firm as per NIT Conditions |
Tender Value
₹14.2 Cr
EMD Value
₹15 L
Closing Date
4 Apr 2022, 6:00 pmClosed
CE AF SHILLONG ZONE
HQ Chief Engineer AF Shillong Zone Military Engineer Services Elephant Falls Camp Nonglyer PO Shillong 793009
PROVISION OF CERTAIN OPERATIONAL INFRASTRUCTURE AT AF STN DINJAN UNDER GE AF MOHANBARI
2022_MES_504760_1
88640/DIN/E8
Open Tender
Civil Works
750 days
GE AF MOHANBARI
As per NIT Conditions
7 documents required · 7 mandatory
₹3,000
Yes
GE AF MOHANBARI
₹15 L
Yes
HQ CE AF SHILLONG ZONE
6 Jun 2022
31 Jan 2022
6 Apr 2022
31 Jan 2022
4 Apr 2022
21 Mar 2022
2 Mar 2022
Amount
SCHEDULE 'A' PART- I (BUILDINGS/STRUCTURES) Details of prepriced Schedule is given in tender documents
SCHEDULE 'A' PART- II ( SITE CLEARANCE, SITE DEVELOPMENT AND EARTH WORK) Details of prepriced Schedule is given in tender documents
SCHEDULE 'A' PART- III (INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- IV (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- V (ROAD/ TARMAC AREA) Details of prepriced Schedule is given in tender documents
SCHEDULE 'A' PART- VI ( SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents
SCHEDULE 'A' PART- VII (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- VIII (FIRM ALARM) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- IX (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents
SCHEDULE 'A' PART- X ( EXTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents
SCHEDULE 'A' PART- XI (LIGHTENING PROTECTION) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- XII (REFRIGERATION AND AIR CONDITIONING ) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- XIII (ELECTROSTATIC DISCHARGE/EARTHING ) Details of prepriced Schedule is given in tender documents
SCHEDULE 'A' PART- XIV (ANTENNA MOUNTING POINT ) Details of prepriced Schedule is given in tender documents
SCHEDULE 'A' PART- XV (CONCRETE PLATFORM ) Details of prepriced Schedule is given in tender documents
SCHEDULE 'A' PART -XVI (MISCELLANIOUS ITEMS) Note:- This schedule is not pre-priced by MES.
INTERNAL ELECTRIFICATION S & F LED Spot light fitting 1 x 7 Watts surface mounted, complete all as specified and directed.
S & F LED security light fittings 1 x 30W with intergral reflector made of aluminium alloy LM6 with LED driver etc and all accessories pre wired and making connection with 3 core PVC insulated sheathed copper conductor cable of suitable size, complete all as specified and directed.
S & F LED Flood light fittings 1 x 30W with intergral reflector made of aluminium alloy LM6 with LED driver etc and all accessories pre wired and making connection with 3 core PVC insulated sheathed copper conductor cable of suitable size, complete all as specified and directed.
Supply and fix 415 Volt MCCB 4 pole, 160 amps, 16 kA with characterstics C ISI marked, complete all as specified and directed.
Supply and fix 415 Volt MCCB 4 pole, 63 amps, 16 kA with characterstics C ISI marked, complete all as specified and directed.
Supply and fix 230 Volt MCB 2 pole, 6-32 amps, 10 kA with characterstics C ISI marked, complete all as specified and directed.
Supply and fix 230 Volt MCB 1 pole, 6-32 amps, 10 kA with characterstics C ISI marked, complete all as specified and directed.
Supply, testing & hanging of energy savingg non-decorative ceiling fan 230 volts, single phase AC, 1200 mm sweep, BEE 5 star rated, Brushless Direct Current (BLDC) without remote type with accessories like holding down rod, hanging clamps, blades, fan hook including writing MES number (as peer standard practice) & flexible three core copper conductor cable of suitable size for connectingg withh ceiling rose complete all as specifed and directed.
Supply anf fix flame proof ceiling fan 1200 mm sweep copper wounded 230 volt 50 Hz with accessories like holding down rod, hanging clamps, blades, fan hook including writing MES number (as per standard practice) & flexible three core copper conductor cable of suibable size for connecting with ceiling rose complete all as specified and directed.
S&F exhast fan metalic steel body, single phase, 230 votls, 50Hz of size 300 mm sweep, 900/950RPM, heavy duty type with suitable metaic louver, blades, frame & flexible three core copper conductor cable of suitable size for connecting with ceiling rose complete including making of hole in wall & making good to thhe disturbed surface complete all as specified.
S&F exhast fan flame proof type, metalic steel body, single phase, 230 volts, 50 Hz of size 300 mm sweep, heavy duty type withh suitable metalic louver, blades, frame & flexible three core copper conductor cable of suitable size for connectingg complete including making of hole in wall & making good to the disturbed surface complete al as specified.
Supply and fix wall mounted fan plastic body single phase, 230V, 50 Hz of size 400mm sweep with suitable blades, frame, inbuilt fan regulator & flexible three core copper cable suitable size connecting with ceiling rose complete all as specified and directed.
M&L for submain wiring with 2 run of FRLS type PVC insulated & unsheathed multistrand copper conductor cable of nominal cross sectional area 10 Sqmm alongwith one run of FRLS type PVC insulated & unsheathed multistrand copper condutor cable of nominal cross sectional area 10 Sqmm as earth continuity conductor drawn through and including concealed PVC conduit non metallic type rigid medium grade , complete, all as specified and as directed.
M&L for submain wiring with 2 run of FRLS type PVC insulated & unsheathed multistrand copper conductor cable of nominal cross sectional area 4 Sqmm alongwith one run of FRLS type PVC insulated & unsheathed multistrand copper condutor cable of nominal cross sectional area 4 Sqmm as earth continuity conductor drawn through and including concealed PVC conduit non metallic type rigid medium grade , complete, all as specified and as directed.
INTERNAL WATER SUPPLY Supplying and fixing 2 way bib Cock with single handle and wall flange, complete all as specified and directed.
Supplying and fixing Health Faucet ABS body with 1 meter SS Braided connection pipe, complete all as specified and directed.
Supplying and fixing pillar cock with aerator, complete all as specified and directed.
Supplying and fixing wall mixer with bend pipe for overhead shower, complete all as specified and directed.
Supplying and fixing overhead shower with revolving joint and shower arm, complete all as specified and directed.
Supplying and fixing Central Hole Basin Mixer with braided connection pipe, complete all as specified and directed.
Supplying and fixing sink cock (wall mounted) with 150 mm long sewivel spout and wall flange, complete all as specified and directed.
Supplying and fixing angle cock with wall flange, complete all as specified and directed.
ROAD/ TARMAC AREA M&L for providing and laying 250mm thick GSB Grade- I of table 400-1 of MORTH, IRC Specification, spreading in layers n. exc 15 cm thick, watering, ramming/rolling by tandem vibratory roller and finishing to longitudinal gradient (1:150) & transverse gradient (1:100) for achieve field compaction at least to 98% of MDD(Maximum Dry Density) of soil complete all as specified and as directed.
Material & Labour for providing 200mm thick (compacted thickness) Wet Mix Macadam (WMM) in two layers (each layer 100 mm thick, compacted separately) with crushed stone aggregate of specified grading, s rolled and consolidated using 8 to 10 tonne capacity tandom vibratory power roller to required gradient and camber to achieve minimum 98% density of MDD determined using modified procter density determination method as per IS 2720(Part-8) and as per MORTH clause 406, complete all as specified and directed.
Material & Labour for 400 Micron thick transparent HDPE Polythene film of GRADE-I conforming to IS-10889 as anti-friction layer on the base course of RUNWAY WORK/ROAD WORK as per specification with specified overlap between adjacent strip and transverse joint etc, complete all as specified and directed. NOTE: Side lap shall be 150 mm and end lap shall be 300 mm. The rate quoted shall be deemed included for the laps.
M & L for Providing and laying 150 mm thick dry lean concrete over a prepared subgrade with coarse and fine aggregate conforming to IS:383, size of aggregate not exc 40 mm (grading and other parameters as per tabel 600-1 of MORTH, IRC SP : 49 specification), design mix(minimum cement content shall not be less than 250 kg/cum) with 7 days compressive strength as 10 N/Sqmm mixed in batching plant, transported to site laid with sensor paver including spreading and compacted by using 8 to 10 tonnes vibratory roller including necessary formwork finishing etc alll as specified and directed. NOTES: (a) No price adjustment shall be applicable if excess quantity of Cement content used in the work as approved in the Design Mix exceed 250 Kg. (b) The rate quoted shall be inclusive of use and waste of form work for total thickness.
Material & Labour for 350mm thick Pavement Quality Cement Concrete (PQC) work in pavement / Dispersal / taxi link of minimum field flexural strength 45 Kg/Sqcm (lower control limit) LCL after 28 days of pavement slab using minimum 450 Kg Ordinary Portland Cement Grade 43 per cum with not exc 31.5mm graded crushed stone aggregate conforming to IS: 383 (grading and other parameters as per table 600-1 of Morth) and mixed with non circular synthetic fibre reinforcement @ 0.25% of weight of ordinary portland cement grade 43 of PQC or as per manufacturers instuction, mixed in batching plant transported to site, laid in panels, spread and compacted using fixed form paver , mechanically vibrated and bull nosing / rounding off the edges, curing compund, finishing the surface by brooming without using extra cement etc including necessary form work etc complete all as specified and directed. Notes : (a) Flexural strength shall be established by beam test and design mix formula should be compatible to as per IRC-44-2017, IS-456. (b) The non circular fibre synthetic reinforcement mixed with concrete shall be measured and paid separately as ‘Supply only’ under respective item of BOQ. (c) All types of joints shall be measured and paid separately under respective items of BOQ. Curing compound shall be applied at the paving stage after broom finish and surface is dry and rate for use of curing compound shall be included in the unit rate quoted.
(ITEM NO 16.26 ... Contd.../) (d) No deduction shall be made from concrete for space occupied by construction and dummy joint. However, deduction shall be made for the space occupied by expansion joints. (e) Cost of any admixtures required to achieve the desired properties of concrete shall be deemed to be included in the unit rate quoted for PQC nothing extra shall be paid on this account. (f) No price adjustment shall be applicable if excess quantity of Ordinary Portland Cement grade 43 content used in the work as approved in the Design Mix exceed 400 Kg. (g) The rate quoted shall be inclusive of use and waste of form work for total thickness. (h) Surface shall be finished by traverse brooming of maximum 1.5 mm deep as per ICAO or as per requirement of Air Force Authority. (j) Ordinary Portland Cement grade 43 shall only be used.
M & L for Forming 20mm wide expansion joint filled with pre-formed expandable synthetic filler board of approved make,provision of closed cell, medium density, cross linked polyurethene back up rod of 25mm dia and sealed with pitch free polyurethene grey sealant( minimum depth of sealant above back up rod shall be 25 mm) conforming to BS-5212 (Type FB) priming the sides as recommended by manufactures instructions and applying masking tapes on edges of joint to prevent accidental spillage of sealant and removing the masking tapes after sealant is appiled, the sealant should have MAF (+)/(-) 30 as used in International Airport in India, complete all as specified.Depth of joint shall be full depth of PQC slab all as specified and direced. Note:-The rate shall include cost of 25mm dia bar.
.M & L for Forming dummy/contraction joints using diamond cutter with initial saw cut with 3 mm blade soon after concrete set for the depth of 84 mm or D/3.Widening the first saw cut to 8 mm wide 25mm deep from top ,priming top 10 mm with approved primer, applying masking tape on edges of joint to prevent accidental spillage of sealant and filling with polyurethene based sealant ( BS - 5212) to closed cell, medium density ,cross linked polyurethene foam back up rod of 10 mm dia ,for complete width of joint and removing the masking tape after filling of sealant and as specified and as per the directions of the manufacturer, complete all as specified and as directed. Note:-The rate shall include cost of 10 mm dia bar
M & L for Forming construction joint 30mm deep X10mm wide using diamond cutter with closed cell, with medium density, cross linked polythylene foam back up rod of 12mm dia, applying bond breaker tape on top of back up rod for complete width of the joint, priming top 10mm with specified primer and filling with polyurethane based sealant ( BS 5212), applying masking tape on edges of joint to prevent accidental spillage of sealant and removing the masking tape after filling of sealant and as specified and as per the directions of the manufacturer, complete all as specified and as directed. Note:- The rate shall include cost of 12 mm dia bar
M & L for applying evenly a tack coat of 2.5 Kg/10 Sqm of VG 10 including claening, swiping with brooms and remove all dust etc from DLC surface complete all as specified and directed.
SEWAGE DISPOSAL Construction of septic tank for 50 users, complete all as specified and shown on drawings.
Construction of soakage well for 50 users, complete all as specified and shown on drawings.
EXTERNAL WATER SUPPLY Supply and laying 3 layer PP-R Polypropylene random copolymer concealed pipes 110 mm outer dia, SDR 7.4 (PN 16) , UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R Plain and brass threaded polypropylene random fittings laid in trenches / wall including all fittings such as socket /Union/Tee/Reducer/Nipple/flanges etc complete all as specified and directed
Supply and fix PPR Gate Valves (Brass Insert) of 50 mm bore, complete all as specified and as directed.
Supply and fix PPR Gate Valves (Brass Insert) of 25 mm bore, complete all as specified and as directed.
Supply and fix PPR Gate Valves (Brass Insert) of 110 mm bore, complete all as specified and as directed.
Material and Labour for constrution of valves pit chamber of size (900 mm x 900 mm x 900 mm, internal ) using PCC (1:4:8) 40 mm graded stone aggregate for foundation 15 cm thick , 23 cm thick wall in CM (1:4) 10 mm thick rendering all around the brick work with 1:6 cement motar PCC (1:2:4) type B1 coping with 20 mm graded agregate for grouting MS top sheet cover with locking arrangement including 50 mm pad lock with double key arrangement MS frame out of 40 x 40x 5 mm thick angle iron including paintaing of steel surface with two coats of synthetic enamel paint over a coat of red oxide primer finishing coat including necessary excavation in any type of soil, returing filling in and removal of surplus soil to adistance not exceeding 50 mtrs all as specified and including demolition / dismantling of existing craked valve chamber complete all as specifeid and directed.
Material and labour for connecting of water supply pipe line in exisiting pipe line including cutting, threading of existing and new pipe line incluing an other material like tee,nut bolts, gaskit etc for making the joint leak proof all as specified and directed
M & L for boring of holes carefully under road / pavement / hard standing by trenches using ultra sound technique and necessary machine without damaging the existing road and getting out in any type of soil and disposal of soil to a distance not exceeding 50 m from the site of work with and including HDPE pipe of 150mm dia suitable for 0.4Mpa working pressure, complete all as specified and as directed.
EXTERNAL ELECTRIC SUPPLY Supply, install, testing and commissioning of LT outdoor Feeder Pillar Box AC 415 V, 50 Hz 3 Phase 4 wire, totally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, protection IP 54 suitable for outdoor use double door type, with bottom cable entry with suitable cable glands structure made out of 3.15 mm thick CRCA steel sheet of minimum size ( 1.5x1.8 x 0.6) m with angle iron frame work and legs of ISA 50X50X5 mm, with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter , changeover switch and MCCBs with sloping canopy at top , double hinged doors at front with suitable locking arrangement including louvers at sides duly powder coated complete for accomodating & including following accessories:- (main panel for Operational infrastructure) BUSBAR :- (a) Aluminium bus bar 800 Amps, supported on non hygroscopic fibres and brass screws for mounting -04 Nos INCOMER:- (a) Supply and fixing ACB (AIR CIRCUIT BREAKER) 4 Pole, 415 Volts of capacity 630 Amps, 50 kA with thermal magnetic release (Manual dropout type)-01 Nos
(ITEM NO 16.41 ... Contd.../) INDICATING DEVICES:- (a) Supply and fixing LED Indicating lamps for Main Supply indicating R, Y, B - 03 Nos (b ) Supply and fixing Digital Ampere Meter 31/2 digit display, 3 phase, class 1 including CT having CTR 650/5 - 01 No (c) Supply & fixing Digital Voltmeter 0-500 Volts, 3 phase, class 1- 01 No OUTGOING FEEDERS:- (a) Supply and fixing MCCB of 3 pole , 415 volts of capacity 63 amps with breaking capacity of 16 KA fixed thermal and fixed magnetic setting - 02 Nos (For Third Floor & Other Buildings) (b) Supply and fixing MCCB of 3 pole , 415volts of capacity 200 amps with breaking capacity of 36 KA, fixed thermal and fixed magnetic setting - 01 No (First Floor) (d) Supply and fixing MCCB of 3 pole , 415volts of capacity 160 amps with breaking capacity of 36 KA, fixed thermal and fixed magnetic setting - 02 Nos (For Ground floor & second floor)
Material and labour for earthing with copper earth plate electrode 600 x 600 x 3.15 mm thick burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using copper earth strip 20 x 3 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipment/ panel/ test point at another end, earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments, 20 dia bore GI pipe 'medium grade' as water pipe from earth chamber to upper edge of earth plate, test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS TMT bars 8mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles including excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate No 3 of SSR Part I and testing on completion complete all as specified and directed.
Material and labour for earthing complete with galvanised mild steel earth plate electrode 600 mm x 600 mm x 6.0mm thick burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 32 x 6 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipment/ panel/ test point at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments, 20 dia bore GI pipe 'medium grade' as water pipe from earth chamber to upper edge of earth plate, test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS TMT bars 8mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles including excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate No 3 of SSR Part I and testing on completion complete all as specified and directed.
Material and labour for earthing complete with galvanised mild steel earth plate electrode 600 mm x 600 mm x 6.0mm thick burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt and electrode connected to and including galvanized earth lead 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by GI protection pipe light garde 15mm dia conected to main earth wire on pole or control board and GI pipe light grade 20mm bore for watering, funnel with wire mesh and PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS TMT bars 8mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles including excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate No 3 of SSR Part I and testing on completion complete all as specified and directed.
Supply and fix LED street light 70 W, 230 volt, AC, 50 Hz endura pearl plus energy saving, environmental friendly, long life exclusive innovation pressure dia cast aluminium IP 66 bay light with high power LEDs as light source and impact resistance of IKO7 with 10 KV Built-in Surge protection device complete all as specified.
Supply and fix cable junction box IP 66 “halogen free and weather proof” for outdoor installation (with metric knockouts for cable entry - Black Colour) minimum size 200 x 160 x 98 mm suitable for 16/25 sqmm, 4 core cable fixed to pole with suitable FI clamp 20X3 mm nuts, bolts and washers incl 01 No miniature circuit breaker (MCBs) single pole, 240 volts, 10 KA, 10 Amps and incl suitable capacity aluminium bus bar (minimum 100 Amps-04 Nos) mounted on insulator complete all as specified and as directed.
Supply and fixing PVC insulated and PVC round sheathed, copper conductor industrial cable 1.5 sqmm, single core of copper conductor for connection of street light fittings on pole from junction box including termination clip complete all as specified or directed.
REFRIGERATION AND AIR CONDITIONING Supply and fix,commosioning,testing and installing of 5 KVA automatic voltage stablizer automatic boost/ buck transformer for low and high voltage with electronic transistors relay/ time relay for two min single phase naturally air cooled, indoor type wall mounted, designed to give output voltage 230 Volt with variation upto +/- 5% at input range between 170 to 250 Volts complete with digital meter for indication of input & output voltage including overload protection, under/ over voltage protection complete all as specified.
DG SET Supplying, installation of silent Diesel Engine Driven generating set 415 volt ,3 phase 4 wire 0.8 PF,engine as per IS 10001/10002 and alternator as per IS 13364 complete with relay panel and switch gears for Automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB norms and foundation of capacity 400 KVA Comprising and including of following:- (A) DIESEL ENGINE: Liquid cooled turbo charged with after cooler to deliver suitable BHP at 1500RPM under NTP conditions of BS 5514 and conforming to IS 10002, DIN 6271 & ISO 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation. Diesel engine of rated speed at full load electric start developing with system with radiator and including electronic governor control of class A1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer conforming to latest CPCB norms on air emission control suitable for electric start with batteries of adequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete with following- (a) Radiator with blower fan or heat exchangar with guard. (b) Pipe coupling for engine cooling system piping. (c ) Corrosion inhibitor coolant (d) Paper element filters (i) Fuel filter (ii) Lube oil filter complete with first filling of lub oil (iii) By pass
(ITEM NO 16.51 ... Contd.../) (e) Fly wheel housing and fly wheel to suit alternator. (f) Engine bearing mechanism in fly wheel housing. (g) Shut off coil with safeties for LLOP/HWT/over speed. (h) Dry type air cleaners and vacuum indicators. (j) Residential silencers silencer conforming to latest CPCB norms on air emission control. (k) Stainless steel exhaust flexible bellows. (l) Motor driven priming pump. (m) Battery charging alternator. (n) Exhaust piping made out of STIC C class, MS pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturer's recommendations to sustain back pressure with rain cap. (o) Mineral wool insulation 2 inch thick suitable for 400 degree Celsius temperature cladded with aluminium sheet 30 gauge for the entire length of exhaust pipe. (p) First fill of oil, coolant and diesel during commissioning and 12 hours testing. (q) Interconnecting copper cabling of adequate capacity batteries control. (r ) Fuel pipe class (s) Self starter (t) Electric operated electronic governor. (u) Fuel injection pump.
(ITEM NO 16.51 ... Contd.../) (v) Electronic instrument panel, complete with all accessories as per manufacturer's specifications displaying the following:- (i) Battery as per manufacturer recommendation. (ii) Water temperature. (iii) lubricating oil pressure. (iv) Engine speed -1500Rpm (v) Engine hours (vi) Frequency. (vii) Voltage. (viii) Safety control (Trip and indication). (ix) High water temperature (x) Low lube oil temperature (xi) Overspeed stop (B) ALTERNATOR- Brushless AC alternator, 3 Phase, 415 Volt, 4 wire, rated for output of 400 KVA ,minimum power factory 0.8, 1500 RPM , insulation class 'H' salient pole, revolving field, single bearing automatic voltage regulator and directly coupled with engine.
(ITEM NO 16.51... Contd.../) (C ) ENGINE INSTRUMENT PANEL- (i) Digital type controller able to display- alternator voltage, battery voltage, load current, fuel level, lub oil pressure, frequency, RPM and able to stop generator on any fault and to display parameters i.e. low battery,LLOP, under voltage, over voltage, High engine temperature and other protection as per manufacturer recommendations including necessary wiring set of relayss, MCB/Fuse etc complete. (ii) Engine start and stop switch (iii) Emergency Stop Switch (iv) DC power supply suitable for controller.
(ITEM NO 16.51 ... Contd.../) (E) BASE PLATE: Common fabricated base frame for engine & alternator made from structural Steel channel, jerk proof on PCC 1:2:4 type B1 foundation including adequate number of anti-vibration pads in adequate quantity all as per the recommendation of the manufacturer (Note:- Cost of suitable size of PCC foundation is deemed to be included in the unit rate quoted by the contractor). (F) DIESEL STORAGE TANK: Fuel tank of MS sheet of capacity not less than 12 Hrs continuous operation on full load with fuel level guage, drain plug, locking arrengements, etc including connection to Engine through fuel filter/ manual feed pump as per manufacturer recommendation. (G) ACOUSTIC ENCLOSURE: Sheet metal fabricatedcope type silent enclosure manufactured on CNC machines as per CPCB norms and power coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75 DB (A) at a distance of 1 M at 75 % load under field condition and 70DB at 3 M from Gen set when DG set is working at full load along with testing conformance, laveling certification etc as laid down in GSR No.371(E) dt 17 May 2002. (H) FOUNDATION: Foundation/ plinth shall be provided as per manufacturers recommendation. (J) MISC: Tool kit operation, maint cat, spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturers standard practice.
SPOT LIGHT Supply and fix LED spot light of capacity 35 W, 230 Volts AC, 50 HZ, track mounted type with compact housing and gear box complete with & including suitable mounting track complete all as specified and directed.
CONCRETE PLATFORM Material & Labour for bringing approved earth as stipulated in 3.22.6 of SSR Part-I from outside MOD land , complete all as specified and directed.
BHARAT ASSOCIATES PVT LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB