Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.8 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹27.7 L+₹26,030 (0.95%)Rejected-AOC | L2 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 3 | L3₹30.0 L+₹2.5 L (9.07%)Rejected-AOC | L3 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 4 | L4₹30.3 L+₹2.8 L (10.4%)Rejected-AOC 135 CHAKRANA TIWARI CHAKA NAINI PRAYAGRAJ 211008 UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211008 | L4 | Rejected-AOC OTHER THAN LOWEST BIDDER |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
31 Dec 2019, 5:00 pmClosed
GE of GE (SOUTH) AKHNOOR
GE SOUTH AKHNOOR C/O 56 APO PIN- 900234
SPECIAL REPAIR BLDG P-42 AND PROVN OF DHOBI GHAT AT 406 SATA REGT WKSP, SPECIAL REPAIR TO BLDG NO T-17, SPECIAL REPAIR TO BLDG NO P-34 INCLUDING SPECIAL REPAIR IN BLDG NO P-1C (GUARD ROOM) AT DIFFERENT LOCATIONS UNDER GE (SOUTH) AKHNOOR.
2019_MES_303751_1
NIT-02
Open Tender
Civil Works
Item Rate
180 days
GE (SOUTH) AKHNOOR
Class D and Category a(i)
8 documents required · 8 mandatory
₹500
GE SOUTH AKHNOOR
₹70,000
Yes
25 Apr 2020
4 Dec 2019
2 Jan 2020
4 Dec 2019
31 Dec 2019
21 Dec 2019
Amount
SCHEDULE 'A' PART-I : BOQ OF WORKS FOR B/R WORKS.
Dismantling asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings, complete all as specified and as directed by Engineer-In-Charge.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc, complete all as specified and as directed by Engineer-In-Charge.
Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) area not exceeding 1.50 Sqm each, complete all as specified and as directed by Engineer-In-Charge.
Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) area exceeding 1.50 Sqm but not exceeding 4.0 Sqm each, complete all as specified and as directed by Engineer-In-Charge.
Taking down shutters of any descriptions area exceeding 1.00 Sqm but not exceeding 2.00 Sqm, complete all as specified and directed by Engineer-In-Charge.
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level), including cleaning, removal and disposal of rubbish/ waste materials from premises, complete all as specified and as directed by Engineer-In-Charge.
Rendering 15mm thick on bricks or concrete masonry surfaces, on walls, in cement mortar 1:6, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-In-Charge.
Rendering 10mm thick on any type of surfaces, on ceiling, in cement mortar 1:3, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-In-Charge.
Rendering 15mm thick on bricks or concrete masonry surfaces, on walls, in cement mortar 1:4, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-In-Charge.
Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., size of frame 125x60mm, complete all as specified and as directed by Engineer-In-Charge.
Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., size of frame 105x60mm, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-10(1:3:6), type C-1, (using 20mm graded crushed stone aggregate), nominal mix, as in cills, steps; plinth courses, string courses, lacing courses, copings, kneelers, apex stones, bed plates and in hold fasts or filling in hollow of steel frame, including necessary form work, complete all as specified and as directed by Engineer-In-Charge.
Butt hinges, size 100mm, medium weight, cold rolled mild steel, and fixed, complete all as specified and as directed by Engineer-In-Charge.
Factory made, plain framed, paneled shutter (two panel) 35mm thick, 2nd class hardwood with lock rail and panel of 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS:1003 (Part-I), kiln seasoned and chemically pressure treated, complete all as specified and as directed by Engineer-In-Charge.
Glazed and skeleton shutters in second class hardwood, 35mm thick, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a); supplied and fitted to chowkhats, complete all as specified and as directed by Engineer-In-Charge.
Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples, complete all as specified and as directed by Engineer-In-Charge.
Mild steel sliding door bolts, size 300mm long, plate type, stove enameled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed, complete all as specified and as directed by Engineer-In-Charge.
Mild steel pressed handles, size 150mm, oval type, stove enamelled black, complete all as specified and as directed by Engineer-In-Charge.
Second class hardwood in small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary labours; articles not exceeding 200 Cucm each, complete all as specified and directed by Engineer-In-Charge.
Aluminium handles, cast type, anodised, size 125mm, complete all as specified and as directed by Engineer-In-Charge.
Factory made steel window, box type, using ERW hollow 'P' section, comprising double frame for and including gauged and glazed skeleton shutter, jointed internally with flat iron 40x4mm complete including grill/ guard bars of 8mm square bars fixed horizontally @100mm C/C including mild steel hinges, handles, tower bolts, stops, lugs etc, complete all as specified and as shown in drawing No- CEUZ/TD-1304, sheet No- 1/3 to 3/3 and as directed by Engineer-In-Charge.
Description all as per serial item No- 22.00 here-in-before but for ventilator top hung.
Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of mild steel tubes for top and bottom rails. Mild steel frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side and as gap insert for top rail and bottom rail; Panelling of plain colour PVC sheet to be fitted in the mild steel frame welded/ sealed to the stiles and rails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at site as per specification and drawing in SSR, complete all as specified and as directed by Engineer-In-Charge.
Solid PVC Door Frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with mild steel square tube, supplying and fixing in opening as per specification and drawing, including making good to disturbed surface of walls, complete all as specified and as directed by Engineer-In-Charge.
Sheet glass, 3.0mm thick, ordinary quality and glazing with oil putty or with wooden beadings, fixing in square not exceeding 0.50Per Square Metre in each pane, complete all as specified and as directed by Engineer-In-Charge.
Preparation of new or previously untreated wood or wooden surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified and as directed by Engineer-In-Charge.
Preparation of new or previously untreated steel surfaces of any description, not otherwise described, over 10cm width or girth including and applying two coats of synthetic enamel paint over one coat of zinc chrome primer, complete all as specified and as directed by Engineer-In-Charge.
Preparation of new plastered or unplastered surfaces of walls and applying two coats of cement paint over one coat of lime wash, complete all as specified and as directed by Engineer-In-Charge.
Preparation of new plastered or unplastered surfaces of walls and applying two coats of distemper oil emulsion over one coat of chalk whiting, on plastered surfaces, preparatory to distempering, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregate), nominal mix, 40mm thick, as in floors, finished even and smooth without using extra cement, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-7.50 (1:4:8), type D-2 (using 40mm graded crushed stone aggregate), as in or as mass concrete in foundation of poles/ stays etc, complete all as specified and as directed by Engineer-In-Charge.
Machine cut kota stone slab, (minimum size shall be 550x550mm), flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete, and including laid over screed bed or bedding layer of mortar 20mm thick in cement mortar 1:6, complete all as specified and as directed by Engineer-In-Charge.
Machine cut kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete, and including rendering 10mm thick in cement mortar 1:4, complete all as specified and as directed by Engineer-In-Charge.
Brass grating, chromium plated, size 125mm, heavy duty, complete all as specified and as directed by Engineer-In-Charge.
Integral waterproofing compound, complete all as specified and as directed by Engineer-In-Charge.
Marble work 18 to 20mm thick (table rubbed and polished), white colour, as in floring, steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade, and including laid over screed bed or bedding layer of mortar 20mm thick in cement mortar 1:6, complete all as specified and as directed by Engineer-In-Charge.
Vitrified Ceramic tiles 10mm thick (square/ rectangular) polished, non-skid, dark shed, area of each tiles not exceeding 0.36 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, and including laid over screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6, complete all as specified and as directed by Engineer-In-Charge.
Vitrified Ceramic tiles 10mm thick (square/ rectangular) polished, non-skid, dark shed, area of each tiles not exceeding 0.36 Sqm, set and fixing in skirting/ dado or any other vertical surfaces and pointed in white or coloured cement to match and including 10mm thick rendering in cement mortar 1:4, complete all as specified and as directed by Engineer-In-Charge.
Bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed for 15mm bore pipe, complete all as specified and as directed by Engineer-In-Charge.
Centre hole wall mixture, chromium plated, with round sport without pop up waste system for 15mm bore pipe, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Granite (of any type) work (table rubbed and polished), 20mm thick, in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-10(1:3:6), type C-2 (using 40mm graded crushed stone aggregate), 50mm thick, as in plinth protection, complete all as specified and as directed by Engineer-In-Charge.
Dismantling of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and as directed by Engineer-In-Charge.
Brickwork with subclass ‘B’ bricks, old size bricks, straight or curved on plan exceeding 6.0mtrs mean radius built in cement mortar 1:6, complete all as specified and as directed by Engineer-In-Charge.
Dismantling water tanks capacity exceeding 250 litres but not exceeding 500 litres and removing to store, complete all as specified and as directed by Engineer-In-Charge.
Rotational moulded polyethylene water storage tanks of 500 liters capacity, (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed for 20mm bore pipe, complete all as specified and as directed by Engineer-In-Charge.
Taking up or down steel tubing of 15mm bore pipe and connections, including cleaning for re-fixing or removal to store, complete all as specified and as directed by Engineer-In-Charge.
Taking up or down steel tubing of 20mm bore pipe and connections, including cleaning for re-fixing or removal to store, complete all as specified and as directed by Engineer-In-Charge.
Tubes, 'medium grade' galvanised, 15mm bore, ISI marked with all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts, etc and fixed complete to walls and ceilings or laid in floors, complete all as specified and as directed by Engineer-In-Charge.
Tubes, 'medium grade' galvanised, 20mm bore, ISI marked with all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts, etc and fixed complete to walls and ceilings or laid in floors, complete all as specified and as directed by Engineer-In-Charge.
Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for 15mm bore pipe, fixed in repairs, complete all as specified and as directed by Engineer-In-Charge.
Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for 20mm bore pipe, fixed in repairs, complete all as specified and as directed by Engineer-In-Charge.
Repair to balcony/ facia and soffit of chajjas by taking down old damaged plaster, over 300mm width or girth by cleaning/ preparing the surfaces by wire brush and rendering 20-25mm thick, in cement mortar 1:3, making surfaces even and smooth, without using extra cement, complete all as specified and as directed by Engineer-In-Charge. Note: Cost of Water proofing compound shall be deemed included in quoted rates.
Mild steel drapery rod, powder coated, decorative type, 20/ 25mm dia, including ends brackets and fixing arrangements, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Oval access doors with seal suitable for 100mm/ 75mm bore cast iron fittings i.e. bends, junctions etc, complete all as specified and as directed by Engineer-In-Charge.
Plate rack (kitchen stand) stainless steel, size 760x910x230mm, thickness of stainless steel sheet not less than 0.80mm, weight not less than 8.00Kg each, fixing by means of electrical drill machine, fasteners and screws, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Dismantling/ taking out of cast iron drain pipes of 100/ 75mm bore (of any specifications), as fixed on walls or laid in trenches, complete all as specified and as directed by Engineer-In-Charge.
Cast iron sand cast soil, waste and vent pipes, 100mm bore, in any length with or without ears, with cement joints, laid in trenches or in floors, fixing in repairs, complete all as specified and directed by Engineer-In-Charge.
Cast iron sand cast soil, waste and vent pipes, 75mm bore, in any length with or without ears, with cement joints, laid in trenches or in floors, fixing in repairs, complete all as specified and directed by Engineer-In-Charge.
Sinks with drainage board made of stainless steel 1.0mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mmx460mm bowl size 410mmx330mmx160mm, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
PVC connections 15mm size with brass nuts of length 450mm, complete all as specified and as directed by Engineer-In-Charge.
Vitreous China wash basin, white, flat back, size 550x400mm excluding taps, waste, chain and plug and porcelain stopper including brackets of any size, including cutting for and pinning in ends of brackets or erecting stand including fixing and supply of waste pipe of 32mm dia, waste coupling of PTMT (half or full threaded), complete all as specified and as directed by Engineer-In-Charge.
Flush pipe of polyethylene of low or high density or PVC, 32mm dia, for low level cistern, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screws as specified, complete all as specified and as directed by Engineer-In-Charge.
Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screws as specified, complete all as specified and as directed by Engineer-In-Charge.
Rolled mild steel sections as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc, conforming to Fe 410-W (Gde- E- 250) quality-A, complete all as specified and as directed by Engineer-In-Charge.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets, complete all as specified and as directed by Engineer-In-Charge.
Mild steel galvanised snap grid frame work for false ceiling, powder coated, comprising of Tee and angle, grid size 605x605mm, including Hangers 6.0mm dia, galvanised iron (upto1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of galvanised iron flat 40x3 mm size 60mm long and expansion hold fasteners 12.50mm dia, 40mm long, including 4.0mm thick everest designer ceiling board, size 595x595mm, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-15(1:2:4), type B-0 (using 12.50mm graded crushed stone aggregate), nominal mix, 25mm thick, as in floors, finished even and smooth without using extra cement, complete all as specified and as directed by Engineer-In-Charge.
Mild steel barrel tower bolts, size 200mm, stove enamelled black, with bright bolt and fixed, complete all as specified and as directed by Engineer-In-Charge.
Mild steel spring for doors, 300mm, ordinary rat tail rod pattern springs including roller and roller plate, complete all as specified and as directed by Engineer-In-Charge.
Preparation of old painted steel surfaces of any description, not otherwise described, over 10cm width or girth including and applying one coat of synthetic enamel paint, complete all as specified and as directed by Engineer-In-Charge.
Preparation of old/ decorated plastered or unplastered surfaces of walls and applying one coat of cement paint, complete all as specified and as directed by Engineer-In-Charge.
Preparation of new plastered or unplastered surfaces of walls and applying three coats of white washing, complete all as specified and as directed by Engineer-In-Charge.
Preparation of old/ decorated plastered or unplastered surfaces of walls and applying one coat of white (Lime) washing, complete all as specified and as directed by Engineer-In-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed by Engineer-In-Charge.
Non-skid, coloured, ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.11 Per Square Metre but not exceeding 0.18 Per Square Metre, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including laid over screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6, complete all as specified and as directed by Engineer-In-Charge.
Glazed ceramic tiles in vertical surface/ dado, size 300x450mm/ 300x200mm, 6/7mm thick, set and jointed in neat cement slurry and pointed in white or colour cement to match, the shade/ colour of tiles including 10mm thick rendering in cement mortar 1:4, complete all as specified and as directed by Engineer-In-Charge.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and as directed by Engineer-In-Charge.
Rolled mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS:1161-1979 grade St.-240, complete all as specified and as directed by Engineer-In-Charge.
Dismantling water tanks capacity exceeding 500 litres but not exceeding 1000 litres and removing to store, complete all as specified and as directed by Engineer-In-Charge.
Rotational moulded polyethylene water storage tanks of 1000 liters capacity, (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed for 20mm bore pipe, complete all as specified and as directed by Engineer-In-Charge.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia, complete all as specified and directed by Engineer-In-Charge.
Reinforced cement concrete M-20(1:1.5:3), type A-1, (using 20mm graded crushed stone aggregate), nominal mix, as in slabs supported on walls, beams and columns, roofs, landings, deck slabs and in shelves and the like, complete all as specified and as directed by Engineer-In-Charge.
Surface excavation not exceeding (not exceeding) 30cm deep and averaging 15cm deep and getting out in any type of soil, complete all as specified and as directed by Engineer-In-Charge.
Removing excavated materials/ soils, to a distance not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed by Engineer-In-Charge.
Plain cement concrete M-10(1:3:6), type D-2 (using 40mm graded crushed stone aggregate), 75mm thick, as in sub base of floors, finish even to recive floor finishes, complete all as specified and as directed by Engineer-In-Charge.
Chequered cement concrete coloured tiles, glossy finish, size 300mmx300mmx20/25mm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over 20mm thick screed bed or bedding layer in cement mortar 1:6, complete all as specified and as directed by Engineer-In-Charge.
Excavation in trenches, not exceeding 1.50 mtr wide and not exceeding 1.50mtr in depth; not exceeding 10 Sqm on plan and getting out, in any type of soil, for trenches/ foundation etc, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-10 (1:3:6), type C-2 (using 40mm graded crushed stone aggregate), as in or as mass concrete in foundation, complete all as specified and as directed by Engineer-In-Charge.
Brickwork with subclass ‘B’ bricks, old size bricks, straight or curved on plan exceeding 6.0mtrs mean radius built in cement mortar 1:4, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-10(1:3:6), type C-2, (using 40mm graded crushed stone aggregate), nominal mix in surface channels and drains, including necessary form work, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-15(1:2:4), type B-1, (using 20mm graded crushed stone aggregate), nominal mix, as in cills, steps; plinth courses, string courses, lacing courses, copings, kneelers, apex stones, bed plates and in hold fasts or filling in hollow of steel frame, including necessary form work, complete all as specified and as directed by Engineer-In-Charge.
Ball valves, PVC, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed for 20mm bore pipe, complete all as specified and as directed by Engineer-In-Charge.
Extra for forming fair finished drain or channel 30 Cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc., complete all as specified and as directed by Engineer-In-Charge.
Galvanised, corrugated mild steel sheeting, 0.80mm thick, with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 275, complete all as specified and as directed by Engineer-In-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25Cm, complete all as specified and directed by Engineer-In-Charge.
Preparation of new plastered or unplastered surfaces of ceiling and applying three coats of white washing, complete all as specified and as directed by Engineer-In-Charge.
Butt hinges, size 50mm, medium weight, cold rolled mild steel, and fixed, complete all as specified and as directed by Engineer-In-Charge.
Aluminium anodised, barrel tower bolts of extruded Section, size 150mm long and fixed, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregate), nominal mix, 100mm thick, as in floors, finished even and smooth without using extra cement, complete all as specified and as directed by Engineer-In-Charge.
Vitreous China squatting pan, ‘Orissa’ pattern, size 580x440mm white, with integral foot rests (excluding flushing cistern and flush pipe) but including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete including making good to dismantled floor in cement concrete M-15 (1:2:4), type B-1 (using 20mm graded crushed stone aggregates), fixing in repair, complete all as specified and as directed by Engineer-In-Charge.
Vitreous China bowl urinal flat back, size of 465x355x265mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern and flush pipe but including of waste pipe), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing flush pipe, grating and union for discharge pipe, fixing in repair, complete all as specified and as directed by Engineer-In-Charge.
Pillar taps, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed for 15mm bore pipe, complete all as specified and as directed by Engineer-In-Charge.
PVC valveless, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, capacity 10.0 litres and making good to dismantled/ damaged surfaces, fixing in repair, complete all as specified and as directed by Engineer-In-Charge.
Grating doom 100mm dia of PTMT (Minimum weight 25gms), complete all as specified and as directed by Engineer-In-Charge.
Rendering 15mm thick on fair faces of brick work or concrete surfaces in sunken floor, in cement mortar 1:3, including mixing water proofing compound @3% by weight in cement, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-In-Charge. Note: Cost of Water proofing compound shall be deemed included in the quoted rate.
Old tubes, 'any grade' galvanised, 15mm bore, with all new fittings such as bends, tees, elbows, unions, short pieces, connectors, back nuts, etc and fixed complete to walls and ceilings or laid in floors, complete all as specified and as directed by Engineer-In-Charge. Note: Cost of cutting/ chasing for pipe line making concealed in surfaces shall be deemed included in quoted rates.
Old tubes, 'any grade' galvanised, 20mm bore, with all new fittings such as bends, tees, elbows, unions, short pieces, connectors, back nuts, etc and fixed complete to walls and ceilings or laid in floors, complete all as specified and as directed by Engineer-In-Charge. Note: Cost of cutting/ chasing for pipe line making concealed in surfaces shall be deemed included in quoted rates.
Brass chromium plated shower rose 125mm size, fancy type, with arms, fixed for 15mm bore pipe, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Dismantling of old/ damaged existing roof treatment with concrete and cleaning all waste and dirt by wire mesh, picking, sweeping and washing down with water to remove dust, etc, and removal of all material out side the cant area, complete all as specified and as directed by Engineer-In-Charge.
Applying one coat of neat cement slurry with 3.0 Kg of cement per Sqm on cleaned surfaces of roof, evenly, complete all as specified and as directed by Engineer-In-Charge.
Water proof treatment on roof top with APP (Ataxic Poly Propylene) modified polymeric five layered membrane with central core of 100 micron high molecular high density polyethylene film, minimum weight not less than 3.0 Kg/ Sqm, 2.0mm thick, centre core is sandwiched on both sides by high quality polymeric mix with properties of high softening point, high heat resistance and cold resistivity to make it ideal for all water proofing treatment, with polymeric mix protection on both sides with 20 micron HMHDPE film, laid over one coat of bituminous primer conforming to IS: 3384, applied @0.40 Kg/ Sqm and one coat of hot blown bitumen of 85/25 grade, conforming to IS:702, applied @1.20Kg/ Sqm on prepared surfaces of roof, overlap should be not less than 150mm at ends and 75mm at sides, joints and overlaps uniformly bounded with LPG torch flame including applying of one coat of semi hot blown bitumen of 85/25 grade, @1.20 Kg Sqm and fine screened sand in dry condition @0.50 Kg/ Sqm after laying the membrane, complete all as specified and as directed by Engineer-In-Charge.
Rendering 10mm thick on fair faces of brick work or concrete surfaces, in cement mortar 1:4, including mixing water proofing compound @ 3% by weight in cement, rendering is to be finished even and smooth (without using extra lime or cement), complete all as specified and as directed by Engineer-In-Charge. Note: Water proofing compound measured and seperatly under respective item of BOQ.
PVC (SWR) pipes, 110mm bore, pressure capacity not less than 4.50 Kgf/Sqcm, single socketed, in any length with rubber ring joints, fixed on wall with mild steel/ PVC clamps, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
PVC (SWR) bends of 110mm bore, pressure capacity not less than 4.50 Kgf/Sqcm, any radius, fixing with adhesive, complete all as specified and as directed by Engineer-In-Charge.
Brickwork with old bricks (except bricks), straight or curved on plan exceeding 6.0mtrs mean radius built in cement mortar 1:6, complete all as specified and as directed by Engineer-In-Charge. Note: Old bricks retrieved from dismantling will be used.
Cleaning of blocked/ choked SGSW/ Cast Iron drain pipes/ sewer lines of any dia and any types, in horizontal or vertical position by rodding, from manholes to manholes and manholes end to septic tanks/ soakage wells, flushing with pressure jet of water/ sewage suction machine after taking out existing manholes covers and putting back manhole covers in original position after cleaning of lines including removing the sludge and other waste materials/ blockage in drain pipes, transport to outside of Unit/ Cantonment area and spreading bleaching powder on top of manholes covers of septic/ soakage pits or in the surrounding areas to make hygienically fit, complete all as specified and as directed by Engineer-In-Charge. Note: Cost of transportation of waste materials shall be deemed included in quoted rates.
Removing of manholes covers (any type) and dewatering/ pumping/ bailing out of contaminated water including cleaning of sludge and night soil from septic tanks/ soakage wells of any capacity and depth alongwith inlet/ outlet chambers etc by vehicle mounted sewage suction machine including pumping out the contaminated water in open drain/ low lying area to a distance exceeding 50mtr and removing the sludge, silt etc. (solid waste materials) to outside of Unit/ Cantonment area and putting back manhole covers in original position including spreading bleaching powder on top of septic tanks/ soakage wells to make it hygienically fit, complete all as specified and as directed by Engineer-In-Charge. Note: (i) Actual quantity of sludge/ waste material only shall be measured after dewatering the septic tanks only, the sludge shall be carried away in the sewage carrying tankers, of minimum capacity 7000 Ltrs each. (ii) Cost of dewatering/ pumping out of contaminated water from septic tanks and soakage shall deemed be included in quoted rates.
Mild steel in framed work such as grills, gratings, door frame etc; with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed stand for cooler mounting; walk ways; railings; wind ties, framework of water tanks and similar work conforming to Fe-290, Gde-E-165, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-15(1:2:4), type B-0 (using 12.50mm graded crushed stone aggregate), nominal mix, 25mm thick, as in floors, finished even and smooth without using extra cement, complete all as specified and as directed by Engineer-In-Charge.
Factory Made Solid PVC Moulded door Shutter with wood free EPS, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC sheet on the front face and 2mm plain colour PVC sheet on back face, supplying and fixing in frame at site as per specification and drawing, complete all as specified and as directed by Engineer-In-Charge.
Taking down shutters of any descriptions, area exceeding 1.00 Sqm but not exceeding 2.00 Sqm and re-fixing in the same openning, complete all as specified and directed by Engineer-In-Charge.
Solid PVC Door Frame of size 18mmx63mm made out of 18mm pre-laminated, coloured PVC ply sheet reinforced with mild steel tubes, supplying and fixing in opening as per specification and drawing, including making good to disturbed surface of walls, complete all as specified and as directed by Engineer-In-Charge.
Factory made solid panel PVC door shutter 20mm thick (style) consisting of frame made out of mild steel tubes for top and bottom rails. Mild steel frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side and as gap insert for top rail and bottom rail; Panelling of plain colour PVC sheet to be fitted in the mild steel frame welded/ sealed to the stiles and rails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at site as per specification and drawing in SSR, complete all as specified and as directed by Engineer-In-Charge.
Anodised aluminium powder coated (minimum thickness of powder coating 50micron) frame for doors, section of frame not less than 111.6x44.75 and 2.44mm thick, windows, ventilators with one or more rebates including joining cleat for fixing etc, complete all as specified and as directed by Engineer-In-Charge.
Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 Kg/mtr including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.). hinges type B-21 100mm long (2 Nos.) suitable handle (1 No.), fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Anodised aluminium powder coated (minimum thickness of powder coating 50micron) openable door shutters with comprising bottom rail section of frame not less than 111.6x44.75 and 2.44mm thick, top rail section 105x44.45 and 2.20mm thick, lock rail 150x44.5 and 3.0mm thick, with door handle locking system (Godrej/ Link/ Harrison), shutters frame including necessary joining cleats, glazing clips, rubber neoprene packing, 150mm long handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc and fixing 5.50mm thick plain glass sheet with rubber packing/ beading, complete all as specified and as directed by Engineer-In-Charge. Note : Cost of door frame, shutter, glass and other filling material in panels shall be deemed included in quoted rate.
Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, cverall length of cover plate 150mm, fixed in floor, complete all as specified and as directed by Engineer-In-Charge.
Door closer, aluminium extruded body section, hydraulically regulated, designation No-03, universal type, suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 kg, complete all as specified and as directed by Engineer-In-Charge.
Sheet glass, 5.50mm thick, ordinary quality and glazing with oil putty or with wooden beadings, fixing in square exceeding 0.50Sqm in each pane, complete all as specified and as directed by Engineer-In-Charge.
Aluminium anodised, barrel tower bolts of extruded Section, size 200mm long and fixed, complete all as specified and as directed by Engineer-In-Charge.
Aluminium handles, cast type, anodised, size 150mm, complete all as specified and as directed by Engineer-In-Charge.
Aluminium alloy, anodised, sliding door bolt, size 300mm, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and as directed by Engineer-In-Charge.
Continuous (piano) hinges, mild steel, bright finish or electrogalvanised, width of recess between flanges (when open) not less than 30mm, complete all as specified and as directed by Engineer-In-Charge.
Preparation of old painted wood/ wooden surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and as directed by Engineer-In-Charge.
Taking out/ cleaning away/ cutting/ uprooting of all grass vegetation, saplings, shrubs, brushwood, undergrowth, roots, and plants on the roof top and alongwith the lateral surfaces of walls of buildings by chiesling and making good to disturbed surface in cement mortar 1:4 including removing rubbish outside the periphery of cantonment area, complete all as specified and as directed by Engineer-In-Charge.
Brass chromium plated, tubular towel rail, 20mm dia, D type, 60cm long between flanges, fancy type, complete all as specified and as directed by Engineer-In-Charge.
Repair to RCC surfaces of balcony facia/ sides and soffit of chajjas, slab or projection over windows by scraping down old damaged plaster/ loose concrete from the surface of any width or girth by cleaning/ preparing the surfaces with wire brush and including fixing netting/ wire mesh of galvanised mild steel wire of 0.91mm dia and 20mm mesh size, applying plain cement concrete M-15, (1:2:4), type B-0 (using 12.50mm graded crushed stone aggregates) with necessary formwork after one coat of neat cement slurry including rendering on prepared surfaces 15-20mm thick, in cement mortar 1:3, making surfaces even and smooth, without using extra cement, including preparation of new plastered surfaces and applying two coats of finishes to match the existing surfaces or exterior emulsion paint (Apex paint) over one coat of primer, complete all as specified and as directed by Engineer-In-Charge. Note: Cost of scaffolding and necessary form work upto triple storied building shall be deemed included in quoted rate, however cost of wire mesh measured and pain separate under relevant item of BOQ.
Bib taps, cast copper alloy, chromium plated, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed for 15mm bore pipe, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Stop valves, cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for 15mm bore pipe, fixed in repairs, complete all as specified and as directed by Engineer-In-Charge.
Stop valves, cast copper alloy, fancy type, chromium plated with long shank and cup (concealed type), screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for 15mm bore pipe, fixed in repairs, complete all as specified and as directed by Engineer-In-Charge.
Vitreous China wash down water closet pan (pedestal pattern), white (including fixing bolts, flush pipe but excluding flushing cistern) and including plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device and making good to dismantled/ damaged floor in cement concrete M-15 (1:2:4), type B-1 (using 20mm graded crushed stone aggregates), complete all as specified and as directed by Engineer-In-Charge.
PVC waste pipe, 32mm bore with cup washers, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Rendering 5mm thick on any type of surfaces, on ceiling, in cement mortar 1:3, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-In-Charge.
Preparation of new/ old plastered or unplastered surfaces of walls and applying wall care putty, 3.0mm thick, as preparation of surfaces before applying any paint or oil emulsion, complete all as specified and as directed by Engineer-In-Charge.
Preparation of old plastered or unplastered surfaces of walls and applying one coat of oil emulsion after preparing of surfaces, complete all as specified and as directed by Engineer-In-Charge.
Preparation of old plastered or unplastered surfaces of walls and applying two coats of cement paint after preparing of surfaces, complete all as specified and as directed by Engineer-In-Charge.
Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications, complete all as specified and as directed by Engineer-In-Charge.
Cast iron ‘P’ or ‘S’ trap, with grating of 100mm outlet dia including jointing to waste pipe fixed in plain cement concrete, M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates), complete all as specified and as directed by Engineer-In-Charge.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) of 150mm internal dia, set in cement mortar, complete all as specified and as directed by Engineer-In-Charge.
Precast reinforced cement concrete M-20(1:1.5:3), type A-1, (using 20mm graded crushed stone aggregate), nominal mix, as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs and similar articles with plain faces as specified in clause No- 4.11.16 of SSR Part-I (2009), set in cement mortar 1:4, complete all as specified and as directed by Engineer-In-Charge.
Preparation of old/ decorated plastered or unplastered surfaces of ceiling and applying one coat of white (Lime) washing, complete all as specified and as directed by Engineer-In-Charge.
Framed work as in doors or gates of angle or other section with gusset plates, Fe 410-W (Gde-E- 250) quality-A, complete all as specified and as directed by Engineer-In-Charge.
Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exceeding 5cm but not exceeding 10cm long, diam of neck 16 to 20mm, complete all as specified and as directed.
Galvanised, corrugated mild steel sheeting, 0.63mm thick, with two corrugations side lap, fixed with L-type or J-type or cranked hook bolts sand washers, in roofs, walls etc. with grade of zinc coating 275, complete all as specified and as directed by Engineer-In-Charge.
Plain, galvanised, mild steel sheeting, 0.63mm thick, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275, fixed with L-type or J-type or cranked hook bolts sand washers, in roofs, walls etc. with grade of zinc coating 275, complete all as specified and as directed by Engineer-In-Charge.
Hardcore of broken stone, gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface
Plain cement concrete M-7.50(1:4:8), type D-1 (using 40mm graded crushed stone aggregate), nominal mix, 100mm thick, as in sub base of floors, finished even, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregate), nominal mix, 50mm thick, as in floors, finished even and smooth without using extra cement, complete all as specified and as directed by Engineer-In-Charge.
Forming 12mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’, for 50mm thick concrete slab, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-7.50(1:4:8), type D-1 (using 40mm graded crushed stone aggregate), nominal mix, 75mm thick, as in sub base of floors, finished even, complete all as specified and as directed by Engineer-In-Charge.
Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade, laid over 30mm thick well rammed sand cushion, with grey cement and no pigment, complete all as specified and as directed by Engineer-In-Charge.
SCHEDULE 'A' PART-II : BOQ OF WORKS FOR E/M WORKS.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc., complete all as specified and as directed by Engineer-In-Charge.
Point wiring (concealed to surfaces) for one light/ fan/ bell point controlled by one switch with 1.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint and with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 1.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge.
Description all as serial item No- 168.00 here-in-before but for one 3- pin, 5-Amps, socket outlet on same board.
Description all as per serial item No- 168.00 here-in-before but for one 3-pin socket outlet 5-Amps on the independent board.
Disconnecting the electric connections and taking down distribution boxes (any type) including MCBs and making good to the disturbed surfaces to match the existing surface, complete all as specified and as directed by Engineer-In-charge.
Point wiring for 3-pin, 15 Amps, switch socket combination on independent board with 2.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, FRLS, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 2.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge.
LED tube light fitting, 20 watt, indoor decorative aluminium extruded T5 LED battens, including LED lamp 20 Watt and connecting up with twin core twisted flexible copper conductor cable of suitable size, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- E-Lite LED Curve LHEXBXPNIN1W020 or equivalent in Bajaj/ Philips/ Osram.
Lamp holder, PVC Polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed by Engineer-In-Charge.
LED retrofit lamp, capacity 9 Watt, B-22 holder base with ploycarbonate body and aluminium heat sink, warm white, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- LHLDEUEEML8R009 or equivalent in Bajaj/ Philips/ Wipro.
Stepped type (multi-steps) electronic regulator for ceiling fan 1200 mm, 240 volts, 100 Watts, single pole, including connecting, complete all as specified and as directed by Engineer-In-Charge.
Switch piano, flush type, single pole, one way, 5 Amps, complete all as specified and as directed by Engineer-In-Charge.
Socket outlet, 2-in-1, 3-pin, 5 and 15 Amps, flush type, complete all as specified and as directed by Engineer-In-Charge.
Switch piano, flush type, single pole, one way, 15 Amps, complete all as specified and as directed by Engineer-In-Charge.
Ceiling rose, three phase/ PVC/ polycarbonate, isolated body, complete all as specified and as directed by Engineer-In-Charge.
Sheet metal enclosures for Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 12-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed by Engineer-In-Charge.
Socket outlet, 2-in-1, 3-pin, 5-Amps, flush type, complete all as specified and as directed by Engineer-In-Charge.
MCB, double pole, 63 Amps, 240 volts, 50 Hz, 'C' curve including necessary incoming and out going electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
MCB, single pole, 6 to 32 Amps, 240 Volts, 50 Hz, including necessary incoming and out going electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
Earthing complete with galvanised iron earth plate electrode 600x600x6mm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, connected with 4.0mm dia GI wire as earth lead, by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 20mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15, type B-1 in pit with precast RCC M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates) in cover reinforced with XPM not less than 4.0 Kg per Sqm, test point etc. all as shown in electric plate No-3 of SSR Part-I (2009), complete with necessary earth work in any type of soil, removal to a distance not exceeding 50mtr, including testing on completion, complete all as specified and as directed by Engineer-In-Charge. Note: Earth pit chamber and RCC pit cover shall be painted with two coats of red synthetic enamel paint over one coat of primer including preparing of surfaces.
Supply and fixing in replacement, 1100 Volts grade, heavy duty, multi-stranded cable, PVC insulated aluminium conductor, multi-stranded, cross sectional area 16 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1.0 metre apart Including 4.0mm suspension wire, one twin core cable flat or circular, complete all as specified and as directed by Engineer-In-Charge.
House service bracket for mounting light fittings House service bracket (hook type complete with 3.0mtr long galvanised iron pipe 40mm dia medium grade, two Nos 90° bends including mild steel clamps, hook, stay, nut, bolt and washer including painting with two coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified and directed by Engineer-In-Charge.
Sheet metal enclosures for Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 8-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed by Engineer-In-Charge.
MCB, double pole, 40 Amps, 240 volts, 50 Hz, 'C' curve including necessary incoming and out going electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
Industrial Bulkhead luminaire environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagon bulk head back-lit LED luminaire comprising of high brightness LED 10 Watt and fixing matrials such as clamps, nuts, bolts, washers etc completed including taking down old unserviceable fittings, complete all as specified and as directed by Engineer-In-Charge. Make: Havells Cat Part No- HEXAFT10WLED857SSYMBOPC or equivalent in Philips/ Bajaj.
PVC insulated FRLS cable with multi-stranded copper conductor 1100 volt grade, size 6.0 Sqmm for connection from MCB distrubition board to Electric Meter by using clips in Meter box, complete all as specified and as directed by Engineer-In-charge. Note: Two runs of cable shall be measured as one unit of length.
Replacement of old unserviceable/ damaged LT XLPE cable with new XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 25.0 Sqmm, 3.50-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed by Engineer-In-Charge.
GI pipes/ Tubes, 'light grade', galvanised, 40mm bore, ISI marked, laid in trenches or fixed to walls/ poles with mild steel clamps, nuts, bolts and washers; for protection of electric cable, complete all as specified and as directed by Engineer-In-Charge.
Sub class ‘B’ bricks, modular size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning for mechanical protection of cable, with width equal to the length of the brick, complete all as specified and directed by Engineer-In-Charge.
Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cm thick, complete all as specified and directed by Engineer-In-Charge. Note: Punned thickness shall be measured.
House service bracket for mounting light fittings House service bracket any type complete with 1.50mtr long galvanised iron pipe 40mm dia medium grade, bent to required shape including mild steel clamps of flat iron 40x6mm, hook, stay, nut, bolt and washer including painting with two coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified and directed by Engineer-In-Charge.
Street light fitting, Pressure die-cast IP 66 LED street light, including LED lamps of 45 Watt and connecting up with twin core twisted flexible copper conductor cable with suitable size, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- LHETAXU7PN6J045/ Crompton Greaves cat part No- LSTP-45-CDL/ Wipro cat part No- LR02-501-XXX-57-XX .
Taking down and re-fixing any where at same site/ locations after spray painting of ceiling fan including sweep size1200mm/ 1400mm, with synthetic enamel paint of white colour by spraying machine including filling cavities with filler, after cleaning all dusts and removing of dent from surfaces including writing of MES Nos. on bottom of fan with synthetic enamel paint of black colour, complete all as specified and as directed by Engineer-In-Charge.
Taking down unserviceable any type of submain wiring etc and making good the disturbed surfaces of walls/ floor etc matching with the existing surface, complete all as specified and as directed by Engineer-In-charge.
Sub main wiring for circuits/ submain wiring alongwith earth wire with two run of 6.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 6.0 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 25mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, complete all as specified and as directed by Engineer-In-Charge.
Bell push switch, single pole, one way, flush type, 5-Amps, 240 volts, complete all as specified and as directed by Engineer-In-Charge.
Switch piano, flush type, single pole, two way, 5 Amps, complete all as specified and as directed by Engineer-In-Charge.
Sheet metal enclosures for Triple Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 4-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed by Engineer-In-Charge.
Taking down and re-fixing any where at same site/ locations after spray painting of exhaust fan including sweeps/ blades of any size, with synthetic enamel paint of white colour by spraying machine including filling cavities with filler, after cleaning all dusts and removing of dent from surfaces including writing of MES Nos. on back of fan with synthetic enamel paint of black colour, complete all as specified and as directed by Engineer-In-Charge.
LED lamp 10/ 12 Watt, T-type and connecting up with twin core twisted flexible copper conductor cable of suitable size, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- LHLDEUECNL8R012 or equivalent in Bajaj/ Philips.
LED tube light fitting, 10 watt, retrofit, 2-fet long, indoor decorative aluminium extruded T5 LED battens, including LED lamp 10 Watt and connecting up with twin core twisted flexible copper conductor cable of suitable size, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- Lumi Line Plus BS10WLED865SPCSS or equivalent in Bajaj/ Philips/ Osram.
LED wall corner light fitting, decorative wall light made up of high grade engineering plastic material suitable for retrofit, including LED lamp 10 Watt and connecting up with twin core twisted flexible copper conductor cable of suitable size, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- LHFHCHE1TL1W020 or equivalent in Bajaj/ Philips.
Door bell, AC, 230 Volts, single pole, ding-dong type sound, completeall specified and as directed by Engineer-In-charge.
LED down light fitting, decorative type, including LED lamp 15 Watt and connecting up with twin core twisted flexible copper conductor cable of suitable size, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- CYLINDROTSS15W830S24DWHT or equivalent in Bajaj/ Philips.
LED COB swivel spotlight fitting, decorative type, including LED lamp 4 Watt and connecting up with twin core twisted flexible copper conductor cable of suitable size, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- LHEEAXPBUG1W004 or equivalent in Bajaj/ Philips.
Plug and socket board, single pole and neutral enclosure with 2 pole and earth metal, including MCB 20 Amps Single Pole and Neutral and all internal wiring with copper wire, making necessary connections, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- DHDPUSN020/DHDPUDP020 or equivalent in ABB/ Legrand/ L&T.
Point wiring (in new concealed conduits to surfaces), modular type for one light/ fan/ bell point controlled by one switch with 1.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint and including FRLS PVC green insulated unsheathed 1.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge. Note: Cost of modular boxes, modular cover plates and different types of modules including anti-corrosive screws shall be deemed included in quoted rate.
Description all as serial item No- 212.00 here-in-before but for one 3- pin, 5-Amps, socket outlet on same board.
Description all as per serial item No- 212.00 here-in-before but for one 3-pin socket outlet 5-Amps on the independent board.
Description all as per serial item No- 212.00 here-in-before but for one light point controlled by two way switches.
Sub main wiring for circuits/ submain wiring alongwith earth wire with two run of 4.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 2.50 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 25mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, complete all as specified and as directed by Engineer-In-Charge.
Point wiring (in new concealed conduits to surfaces), modular type, for 3-pin, 15 Amps, switch socket combination on independent board with 2.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, FRLS, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint and including FRLS PVC green insulated unsheathed 2.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge. Note: Cost of modular boxes, modular cover plates and different types of modules including anti-corrosive screws shall be deemed included in quoted rate.
Modular stepped type (multi-steps) electronic regulator for ceiling fan 1200 mm, 240 volts, 100 Watts, single pole, including connecting, complete all as specified and as directed by Engineer-In-Charge.
Modular bell push switch, single pole, one way, 5-Amps, 240 volts, complete all as specified and as directed by Engineer-In-Charge.
Modular socket outlet, 2-in-1, 3-pin, 5-Amps, complete all as specified and as directed by Engineer-In-Charge.
Modular switch piano, single pole, one way, 5 Amps, complete all as specified and as directed by Engineer-In-Charge.
Modular switch piano, single pole, two way, 5 Amps, complete all as specified and as directed by Engineer-In-Charge.
Modular Socket 6Amps/ 16Amps, 2/3-pin combined, 2-module,, complete all as specified and as directed by Engineer-In-Charge.
Modular switch piano, single pole, one way, 15 Amps, complete all as specified and as directed by Engineer-In-Charge.
MCB, four pole, 63 Amps, 240 volts, 50 Hz, 'C' curve including necessary incoming and out going electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged LT XLPE cable with new XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 35.0 Sqmm, 3.50-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed by Engineer-In-Charge.
Amount of Schedule of credit of for Rs 69,316.00 shall be deducted from quoted amount.
M/S Rajesh Kumar Contractor
JR CONSTRSTRUCTION CO.
VIJAY BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .