Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 LAccepted-AOC A 14 USHA SADAN NEAR POST OFFICE COLABA MUMBAI 05 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | L1 | Accepted-AOC being lowest | |
| 2 | L2₹17.5 L+₹6.3 L (56.6%)Rejected-Finance | L2 | Rejected-Finance Higher amount quoted | |
| 3 | L3₹19.7 L+₹8.5 L (75.9%)Rejected-Finance JAISALMER | BARMER | RAJASTHAN | 344001 | L3 | Rejected-Finance Higher amount quoted | |
| 4 | L4₹25.5 L+₹14.3 L (127.6%)Rejected-Finance PLOT NO 14 SHIV COLONY KATI GHATI RAJGARH ROAD ALWER RAJ | ALWAR | ALWAR | RAJASTHAN | L4 | Rejected-Finance Higher amount quoted |
Tender Value
Refer Docs
EMD Value
₹59,100
Closing Date
11 Jan 2022, 6:00 pmClosed
CWE (A) Jaisalmer
CWE (A) Jaisalmer
REPAIR TO INTERNAL ELECTRIFICATION WORKS IN AREA UNDER AGE (I) POKARAN
2021_MES_491580_1
83989
Open Tender
Electrical and Maintenance Works
Works
270 days
Pokaran
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (A) Jaisalmer
₹59,100
Yes
10 Mar 2022
30 Nov 2021
13 Jan 2022
30 Nov 2021
11 Jan 2022
15 Dec 2021
Amount
Taking down carefully copper/aluminum point wiring (light/fan/socket power) complete, including fixture and fitting such as switches, ceilling roses, pendants, regulators, socket, light fittings etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfases of walls, floors, etc complete all as specified and as directed.
Taking down main switches/DB'S alongwith existing board,MCB including removing the same from site and making the good to the disturbed surface complete all as specified and as directed.
Taking down the existing unserviceable sub main wiring of any type/description as existing at site including making good the disturbed surfaces to match with the existing finishes all as specified.
Taking down the existing old unserviceable LT cable of size 10 sqmm x 2 core complete all as specified and directed at site.
Taking down old unsv building security light fittings
M&L for point wiring for light/Fan point using colour coading as per IS with 1.5 sqmm multistranded copper conductor single core FRLS PVC insulated unsheathed 1100 volts ,ISI-694 marked drawn through medium grade PVC casing caping and accessories on wall/roof/floor etc(ISI marked0 with mild steel/pressed steel sunken box 1.6 mm thick (with earth dolly) duly painted with two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally,covered with 3 mm thick plastic laminated sheet cover for fixing of switches,socket and fan regulators etc including PVC insulated multistranded copper conductor 1.5 sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earh duly complete including making good of disturbed surfaces of wall in same specification as per existing complete all as specified and directed for the following:-
All as per ser item No 6 here-in-before but bell point point controlled by one, one way bell push comple all as specified and directed at site.
All as per ser item No 6 here-in-before but socket outlet 3 pin 5 amps same board comple all as specified and directed at site.
All as per ser item No 6 here-in-before but socket outlet 3 pin 5 amps Ind board comple all as specified and directed at site.
All as per ser item No 6 here-in-before but socket outlet 3 pin 15 amps ind board with provision of 2x 2.5 sqmm (phase & neutral) PVC insulated copper conductor cable and 1x 2.5 sqmm as earth continuity conductor on independent board complete all as specified and directed at site.
All as per ser item No 6 here-in-before but geyser/AC socket ind board with provision of 4 x 4.00 sqmm (phase & neutral) PVC insulated copper conductor cable and 1x 4.00 sqmm as earth continuity conductor on independent board complete all as specified and directed at site.
M&L for point wiring for light/Fan point using colour coading as per IS with 1.5 sqmm multistranded copper conductor single core FRLS PVC insulated unsheathed 1100 volts ,ISI-694 marked drawn through and including heavy duty ISI marked PVC concealed conduit alongwith its accessories of suitable size, with modular steel boxes of 1.6 mm thick,60 cm depth of suitable size including fixing/grouting modular boxes as per site requirement and making good to match with existing finishes including modular plate with frame suitable for mounting of modular switches/modular sockets/modular regulators etc with screw etc including running up of 1.5 sqmm copper conductor FRLS,PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly es/socket/regulator including making good of disturbed surfaces of wall in same specification as per existing shape complete all as specified and directed for the following:-
All as per ser item No 12 here-in-before but socket outlet 3 pin 5 amps same board comple all as specified and directed at site.
All as per ser item No 12 here-in-before but socket outlet 3 pin 5 amps Ind board comple all as specified and directed at site.
All as per ser item No 12 here-in-before but bell point point controlled by one, one way bell push comple all as specified and directed at site.
All as per ser item No 12 here-in-before but socket outlet 3 pin 15 amps ind board with provision of 2x2.5 sqmm (phase & neutral) PVC insulated copper conductor cable and 1x 2.5 sqmm as earth continuity conductor on independent board complete all as specified and directed at site.
Supply and Fix switch piano,flush type ,5 amps,230 volts,single pole,one way (ISI marked) complete all as specified and as directed.
Supply and Fix switch piano,flush type ,15/16 amps,230 volts,single pole,one way (ISI marked) complete all as specified and as directed.
Supply and Socket outlets multipurpose 2 in 1,3 pin ,5 amps flush type conforming to IS complete all as specified and directed at site.
Supply and Socket outlets multipurpose 2 in 1, 5/15 amps flush type conforming to IS complete all as specified and directed at site.
S&F ceiling rose three terminals PVC/polycarbonate isolated body complete all as specified and directed at site.
Supply and Fix bell push, 5 amps,230 volts, (ISI marked) complete all as specified and as directed.
S&F fan regulator step type ,240 volts complete all as specified and directed at site.
Supply and Fix modular switch 6 Amp 1 module, 240 volts complete all as specified and as directed.
Supply and Fix modular switch 16 Amp 1 module, 240 volts complete all as specified and as directed.
Supply and Fix modular Socket 6A -2/3 Pin combined,2 module, 240 volts complete all as specified and directed at site.
Supply and Fix modular Power Socket 6A/16A-2/3 pin combined 2 module, 240 volts complete all as specified and directed at site.
S&F modular fan regulator,120 w-2 module complete all as specified and directed at site.
Supply and Fix modular bell switch 6 Amp 1 module, 240 volts complete all as specified and as directed.
Supply and Fix Buzzer, Ding Dong AC 230 v,50 Hz complete all as specified and as directed.
M&L for lamp holder,PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and directed by Engineer-in-Charge
S&F MCB SP 6 to 32 Amps 240 volts 'C' series 10 KA complete all as specified and directed at site.
S&F MCB SPN 40 Amps, 240 volts 'C' series 10 KA complete all as specified and directed at site.
Supply and fix MCB DB SPN 8 way double door IP-43 suitable for housing of MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed at site.
Supply and fix MCB DB SPN 4 way double door IP-43 suitable for housing of MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed at site.
S & F LED building Security light fitting 1 x 20 watt with polycarbonate housing, Aluminum gear tray duly prewired inbuilt LED module IP 65 Protection complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of size 1.5 sq mm complete all as specified and directed
S&F in replacement service bracket for street light fitting made out of 40 mm bore light grade GI pipe of length 1.2 mtr long (approx) bend to shape 115 degree and fix to pole for fixing of street light fitting on pole/wall etc fixed with 2 Nos 32x 6 mm GI clamp, Nut,bolts,washer etc complete all as specified and directed.
M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of strata, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed. Note : (i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) Item includes cost of 7.5 M earth lead wire. Any variation in length shall be adjusted through deviation order.
S&F in repair service connection of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathed of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core multistandard cable flat or circular of 6 Sqmm 2 core including taking down old service cable complete all as specified & directed by Engineer-in-charge.
Supply and fix in repair 36 watts CFL lamp 4 pin type suitable single phase, 240 Volts, 50 Hz complete all as specified & directed by Engineer-in-charge. (Make :- Bajaj /Crompton Greaves as approved by GE).
Supply and fix in repair 11 watts CFL lamp 2 pin type suitable single phase, 240 Volts, 50 Hz complete all as specified & directed by Engineer-in-charge. (Make :- Bajaj /Crompton Greaves/Havells as approved by GE).
M&L for Sub main wiring complete with 2x6 Sqmm, single core, multi stranded copper conductor FR PVC insulated and sheathed cable 1100 Volts grade, drawn in concealed/surface PVC conduit as per direction of engr-in-charge, required along walls/ roofs etc including 6 sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly including taking down old burn out sub main wiring complete all as specified and directed at site.. Note:- All three wire/cable(phase, neutral and earth) should be run through for each individual circuit from the DBs & painting over surface conduit to be done to match with walls/ ceiling existing surfaces.
Supply and Laying in trenches/through pipes/ducts or on poles/walls jointing to O/H conductor, LT panels, main switch with cable size aluminum lugs and testing. XLPE insulated, armoured heavy duty electric cables with aluminum conductor, 1100 volt grade, all as specified directed by Engineer In charge of cross sectional area of 10 Sqmm 2 core
S & F LED batten suitable for 1X18 w T5 and T8 lamps with connectiong up with twin core twisted flexible copper conductor cable complete all as specified and directed by Engineer in charge. Make Havells cat Part No REGALBATTENT5UPTO1X18WDSBSWH or equivalent
S & F 1X18 watt LED polycarbonate Tubelight with very high efficacy suited for installation in existing T8 fitting with G13 Lamp holders including electric connection complete all as specified and directed by Engineer Incharge Make Havells cat part No PHOTONNULTRAE2.01213T8SSTL18WLED865SPC or equivalent
S&F B22 base13 watt 4 star rating LED lamp all as specified and directed at site.
S & F recessed mounting LED Square downlighter luminaire with die cast aluminium housing 15 watts incl provn of three core cable size 1.5 Sq.mm from ceiling rose to fitting with all accessories and all as specified and directed by Engineerin Charge Make- Crompton greaves Limited LSDN-15-CDL/TL/WW or Equivalent make of Havells/Philips.
S & F recessed mounting LED round shape downlighter with all accessories and all connections as specified and directed by Engineer-in-Charge, Make : Crompton greaves Limited LSDN-15-CDL/TL/WW or Equivalent make of Havells/Philips.
S & F LED post top lantern energy savin spun aluminium landscape with all accessories and connection all as specified and directed by Engineer-in-Charge, Make : HAVELLS RUBYMINIPT15WLED757PSYMTOPC or Equivalent make of Crompton/Wipro/Philips.
S & F single pole and nutral enclosure 10 A with a two pin and earth plug and socket complete with one single ple and nutral MCB complete all as specified & directed by Engineer-in-Charge
Taking down of unsv ceiling fans/exhaust fans sealing cable end,dismantling blades and removing fan and blades to store complete all as specified and directed at site.
M& L for rewinding of 1200 mm sweep ceiling fans of any make with super enameled copper winding wire of existing gauge as per old copper winding including providing insulation be varnishing (Golden), Cleaning, Oiling, Greasing, nut, bolt capacitor stand etc and refixing all the parts complete and Painting of ceiling fans of any size complete incl blades, with synthetic enamel paint by spraying including filling cavities with filler, one coat after celaning all dust etc. testing in E/M Store yard and fixing, hanging complete all as specified and directed by Engr-in-charge.
All as per item No 53 here in before but 300 mm sweep exhaust Fans
All as per item No 53 here in before but 450 mm sweep exhaust Fans
All as per item No 53 here in before but 600 mm swwep exhaust Fans
Overhauling of 1200 mm sweep ceiling fans, cleaning, oiling, Greasing,nut, bolt, capacitor stand etc complete testing all as specified & directed by EIC Note : (i) Any Un-serviceable parts required for replacement shall be measured and paid separately. (ii) overhauling of ceiling fans shall be done at MES store yard, No Extra payment shall be made on this account.
Hanging only ceiling fan and connecting up including provision of cable from ceiling rose to connector to fan complete all as specified and directed at site.
Fixing only exhaust fan and connecting up incuding provision of cable from ceiling rose/connector to fan complete all as specified and directed at site.
S&F in replacement of ball bearing (6201) suitable for Ceiling/Exhaust Fans complete all as specified and directed by Engineer-In-Charge: -
All as per ser item No 60 here in before but size of ball bearing 6202
All as per ser item No 60 here in before but size of ball bearing 6203
All as per ser item No 60 here in before but size of ball bearing 6204
Supply and fix in replacement Gun Metal bushes suitable of ceiling fans complete all as directed by EIC.
Supply and fix in replacement of Shaft suitable of ceiling fans complete all as directed by EIC.
Supply and fix in replacement Rubber reel suitable for ceiling Fans complete all as specified and directed by EIC.
Supply and fix in replacement of repair ‘U’ brackets, Nuts and bolts suitable for Rubber Reel of ceiling Fan (Any type, sweep and make) complete all as specified and directed by EIC.
Supply and fix in repair Twin core copper flexible cable of size 1.5 Sqmm PVC insulated 1100 volts for ceiling fans.
Supply and fix in repair capacitor 2.5 MFD paper insulated with aluminium body after removing unserviceable condenser complete all as specified and directed by EIC.
Supply and fix in replacement 3 pin plug top 16 Amp.
M&L for taking down geyser of cap 50 ltrs of any type/Make for existing position and location for refixing after carrying out following repairs :- (a) Dismantling geyser complete (b) Supply and replace brass door inlet outlet connection assy complete including rubber ring/gasket, screws, nuts and washers complete. (c) Cleaning & descaling inner vessel assy and pressure leakage testing.
All as per ser item No 71 here-in-before but Geyser cap of 25 ltr complete all as specified and directed at site.
M&L in repair stop valves 15mm dia bore cast copper alloy high pressure, both ends screwed.
Taking down old unsv PVC connection pipe upto size of 15 mm X 900 mm complete
Supply and replace PVC connection heavy duty, nylon braided, suitable for hot water, with brass alloy chromium plated nuts and nylon washers complete of size15mm dia x 45cms long all as directed
All as per ser item No 74 here-in-before but 600mm long
Supply replace and connect in repairs PVC insulated and sheathed 1100 Volts grade flexible three core insulated and sheathed multistranded copper condudtor cable of size 40/.0076mm.
Supply and fix in repair heating element ISI marked of suitable for 25 ltr geyser including rubber ring clamping screws etc complete Make : BAJAJ/VENUS/THEETA
All as per ser item No 77 here-in-before but suitable for 50 ltrs geyser
Supply and fix in repair thermostate switch ISI marked for geyser as per existing of range 15-65 degree temparature
Supply and fix in repair brass nut fusible plug
M&L for grouting rack bolt for holding geyser upto 50 ltrs in wall including making good and matching existing surface and finish all as directed.
ALPHA ENGINEERING COMPANY
M/s Shri Inder Construction Company
M/s Yash Electrical and Maintenance
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .