Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹39.9 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹43.3 L+₹2.4 L (5.98%)Rejected-AOC | 2 | Rejected-AOC Not L1 | |
| 3 | 3₹45.1 L+₹4.3 L (10.5%)Rejected-AOC B 33 171 PATEL NAGAR GURUDASPUR ROAD PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | 3 | Rejected-AOC Not L1 | |
| 4 | 4₹46.7 L+₹5.9 L (14.4%)Rejected-AOC DUDH LINE NAYAGAON VILL SHADIPUR POST SRI VIJAYA PURAM TEHSIL SOUTH ANDAMAN 744106 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744106 | 4 | Rejected-AOC Not L1 | |
| 5 | 5₹47.8 L+₹7.0 L (17.1%)Rejected-AOC KTA ROAD LAMBA LINE JUNGLIGHAT PO PORT BLAIR 744103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | 5 | Rejected-AOC Not L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
9 Jun 2021, 6:00 pmClosed
GE Brichgunj
GE Brichgunj, Port Blair
REPAIR AND MAINTENANCE OF STREET LIGHTS LT DISTRIBUTION SYSTEM EARTHING SYSTEM SUMMER COOLING APPLIANCES WATER SUPPLY LINES AND OH TANKS AND REPAIRS REWIRING OF BUILDINGS AT AF STATION UNDER GE BRICHGUNJ
2021_MES_438055_1
GEBG 8124A
Open Tender
Civil Works
Item Rate
270 days
Brichgunj
As per NIT
8 documents required · 8 mandatory
₹500
GE Brichgunj
₹80,000
Yes
16 Jul 2021
23 Apr 2021
11 Jun 2021
23 Apr 2021
9 Jun 2021
10 May 2021
Amount
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick burried directly in ground earth pit not less than 2.25 M deep below ground level with top edge of the plate not less than 1.5 M below normal ground level connected to galvanised strip of 25x4 mm by means of nuts, bolts, checknuts, washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part I of 2009 connected to earthing test point or disconnecting / testing link including excavation/ earth work in any strata, removal of surplus earth, GI pipe medium grade 20 mm for watering and funnel, GI Pipe light grade 40mm dia for earth lead protection, PCC 1:3:6 type C1 chamber with chamber cover in RCC 1:2:4 type B1 including taking down of existing earthing complete all as specified and as directed
Excavation in trenches not exceeding 1.50m wide and n.exc 1.5m depth for foundation, laying of UG cables / pipeline etc or for shafts, wells, cesspits, manholes, pier holes etc not excluding 10 Sqm on plan in hard/dense soil and getting out , complete all as specified and as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n.exc. 25cm in any type of soil complete all as specified and directed.
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point as directed.
Supply and filling pulverized stone dust to the full width of trenches for protection of cables including spreading and punning down including watering consolidation complete all as specified. Note : Thickness of stone dust will be paid after cushioning after punning.
Supplying and laying unreinforced Precast Cement Concrete Cable Covers, Class LV, Type - 1, Flat, size 250mm X 150mm X 40mm in trenches for cable protection, embossed with "ELECTRIC" on the top surface incl taking down old cover complete all as specified and as directed.
Disconnecting and taking out old defective LT UG cable with aluminium conductor of any size/type from trenches/ walls/ poles/ pipes all as directed and as specified.
Supply,laying,jointing,connecting and testing of underground XLPE insulated,PVC seathed, armoured heavy duty electric LT cable,1100volts grade with aluminium stranded conductor,10sqmm 4core,laid in trenches/fixed to poles/drawn through pipes with suitable size cable glands,crimping type cable lugs,sockets etc.complete and taking down the existing cable all as specified and directed.
Description all as item No 8 hereinbefore but cable of size 16 Sqmm 4 Core all as specified and as directed.
Description all as item No 8 hereinbefore but cable of size 25 Sqmm 3.5 Core all as specified and as directed.
Description all as item No 8 hereinbefore but cable of size 35 Sqmm 3.5 Core all as specified and as directed.
Description all as item No 8 hereinbefore but cable of size 50 Sqmm 3.5 Core all as specified and as directed.
Description all as item No 8 hereinbefore but cable of size 70 Sqmm 3.5 Core all as specified and as directed.
Description all as item No 8 hereinbefore but cable of size 95 Sqmm 3.5 Core all as specified and as directed.
Description all as item No 8 hereinbefore but cable of size 10 Sqmm 2 Core all as specified and as directed.
Description all as item No 8 hereinbefore but cable of size 120 Sqmm 3.5 Core all as specified and as directed.
Description all as item No 8 hereinbefore but cable of size 240 Sqmm 3.5 Core all as specified and as directed.
Supply and lay PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, conforming to IS 694 of size 2.5 Sqmm 2 Core complete including taking down old cable all as directed and as specified.
Supply, laying and fixing in replacement 50mm bore GI pipe light grade for necessary road crossing, culverts etc for cable protection all as specified and as directed.
Supply, laying and fixing 40mm bore in replacement GI light grade for necessary road crossing, culverts etc for cable protection all as specified and as directed.
S & F in replacement Street light timer panel 3 phase of maximum load 6 KW with time switch, contactor rating 40A /TP, MCB rating 40A all as directed and as specified by Engineer-in-Charge
Supply, replacing and fixing LED street light 70W dc driver 230V, outdoor type heavy duty of suitable size street light fitting after taking down fitting and refixng back on pole all as specified and directed.
Supply, replacing and fixing LED street light 40W dc driver 230V, outdoor type heavy duty of suitable size in street light fitting after taking down fitting and refixng back on pole all as specified and directed.
Supply and fix in replacement outdoor type FRP junction box of size 300x200x105mm, light weight suitable for pole mounting using clamps/bolts and nuts including MCB SP 6 Amps single pole and necessary connector for loop in loop out cable connection complete all as specified and as directed.
Supply and fix in replacement outdoor type FRP junction box of size 140x140x105 mm, light weight suitable for pole mounting using clamps/bolts and nuts including MCB SP 6 Amps single pole and necessary connector for loop in loop out cable connection complete all as specified and as directed.
Supply and fix in replacement 25 x 4 mm GI strip as earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required complete all as specified and as directed.
Supply and fix in replacement 75W LED flood light of Pressure die cast housing and powder coated, system wattage 75W, IP protection = IP 66, PF≥ 0.90 all as specified and directed.
M&L for painting on old surfaces LT panel by spray paint after cleaning strains and grease/oil spots with sand paper & thinner and painting the cleaned surface with synthetic enamel paint of existing colour to achieve good finish by applying two coats of paints by spray painting machine carefully after disconnection of power supply and covering the meters, indicators and switches to prevent from fall of paint drop on them all as directed and as specified by Engineer in Charge.
Supply and jointing as in repair straight through joint, outdoor type 1100 volts grade, heat shrinkable type suitable for 3.5 core, 240 Sqmm to 300 sqmm LT, XLPE cable and testing after jointing complete all as specified and as directed.
Supply and jointing as in repair straight through joint, outdoor type 1100 volts grade, heat shrinkable type suitable for 3.5 core, 150 Sqmm to 185 sqmm LT, XLPE cable and testing after jointing complete all as specified and as directed.
Supply and jointing as in repair straight through joint, outdoor type 1100 volts grade, heat shrinkable type suitable for 3.5 core, 70 Sqmm to 120 sqmm LT, XLPE cable and testing after jointing complete all as specified and as directed.
Supply and jointing as in repair straight through joint, outdoor type 1100 volts grade, heat shrinkable type suitable for 3.5 core, 25 Sqmm to 50 sqmm LT, XLPE cable and testing after jointing complete all as specified and as directed.
Supply and jointing as in repair straight through joint, outdoor type 1100 volts grade heat shrinkable type suitable for 2/4 core, 10 to 16 Sqmm LT XLPE cable and testing after jointing complete all as specified and as directed.
Supply and jointing in repair end termination, outdoor type 1100 volts grade heat shrinkable type suitable for 70 to 120 Sqmm LT XLPE cable and testing after jointing complete all as specified and as directed.
Supply and jointing in repair end termination, outdoor type 1100 volts grade heat shrinkable type suitable for 240 to 300 Sqmm LT XLPE cable and testing after jointing complete all as specified and as directed.
Supply and fix in replacement aluminium crimping type lugs of size 10 sqmm complete all as specified and as directed.
Supply and fix in replacement aluminium crimping type lugs of size 16 sqmm complete all as specified and as directed.
Supply and fix in replacement aluminium crimping type lugs of size 25 sqmm complete all as specified and as directed.
Supply and fix in replacement aluminium crimping type lugs of size 35 sqmm complete all as specified and as directed.
Supply and fix in replacement aluminium crimping type lugs of size 50 sqmm complete all as specified and as directed.
Supply and fix in replacement aluminium crimping type lugs of size 70 sqmm complete all as specified and as directed.
Supply and fix in replacement aluminium crimping type lugs of size 95 sqmm complete all as specified and as directed.
Supply and fix in replacement aluminium crimping type lugs of size 120/150 sqmm complete all as specified and as directed.
Supply and fix in replacement aluminium crimping type lugs of size 240 sqmm complete all as specified and as directed.
Supply, install and connection of LT outdoor loop-in loop-out terminal box with sloping canopy of size 600x450x300mm made out of 3.15mm thick CRCA sheet duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, front and rear hinged doors mounted on 25x25x4mm MS angle iron frame 60cms height, erected in ground with PCC foundation (1:4:8) type D-2 (using 40mm graded stone aggregate) including Supply and fix in repair insulated aluminium bus bar of size 40x5 mm for 3 phase and neutral respectively mounted on insulators and terminating with suitable cable with glands including taking down old terminal boxes complete all as specified and as directed.
M&L in replacement of Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint all as directed.
M & L for PCC (1:3:6), Type C-1, (using 20 mm graded stone aggregate) as in Coping and the like including weathering, slightly rounded or chamfered angles and throating including formwork [straight or curved] complete all as specified and directed.
M&L for repairing the existing LT Panel/ feeder Pillar Box any type or size by taking proper shutdown, disconnecting and reconnecting cables, welding/drilling for smooth funtioning of panel door, locking arrangement complete all as directed and as specified by Engineer in Charge.
Supply and fix in replacement indicating lamps LED type set (R,Y,B) all as specified and directed
S &F in replacement CT Coil suitable 250/5A for different load all as directed
Supply, fabricating, fixing the CRCA sheet metal of any thickness for the body/door of the LT Panel of required size including cutting /removing of existing unserviceable part , making appropriate hole for proper cable entry/exit and with proper fasteners required as per site requirement all as specified and directed.
Supply and fix in replacement solid aluminium bus bar for 3 phase and 01 neutral of size as per the load or as specified by engineer in charge, including space provided for internal wiring of the panel and holes are to be provided for proper fasteners as required including taking out of unserviceable aluminium bus bar all as specified and as directed
Supply and fix in replacement Speader terminals suitable for MCCB of capacity 200A all as directed and as specified.
Description all as item 55 hereinbefore but for 250A capacity all as specified and as directed.
Supply only insulation tape 6m long for electrical insulation.
Supply and fix in repair energy saving LED Garden light of 10 W LEDs made up of aluminium casting with acrylic diffuser for soft illumination effect and the bollard trunk is of black powder coated with silver white finish for tripod stand with the following specification complete all as specified and as directed
Supply and fix in replacement energy saving LED Garden light of 8W LEDs made up of aluminium casting with acrylic diffuser for soft illumination effect complete all as specified and as directed :-
Supply and fix in replacement energy saving LED Garden light of 10 W LEDs made up of aluminium casting with polycarbonate diffuser for soft illumination effect and the bollard trunk is of black powder coated complete all as specified and as directed :-
Supply and fix in replacement energy saving LED Garden light of 15 W LEDs made up of aluminium casting with polycarbonate diffuser for soft illumination effect and the bollard trunk is of black powder coated complete all as specified and as directed :-
Supply and fix in replacement energy saving LED light 20W security light matching the existing pattern of aluminium casting with polycarbonate diffuser for soft illumination effect and powder coated complete on existing GI pipe all as specified and as directed.
Supply and fix in replacement energy saving LED street lightthan 36W matching the existing pattern of aluminium casting with polycarbonate diffuser for soft illumination effect and powder coated complete on existing GI pipe all as specified and as directed.
Supply and fix in replacement energy saving LED street light 70/75 W matching the existing pattern of aluminium casting with polycarbonate diffuser for soft illumination effect and powder coated complete on existing GI pipe all as specified and as directed.
Supply and fix in replacement high mast Flood Light fitting 120W energy efficient and IP65 water proof with anti glare diffuser all as directed and as specified.
Supply and fix in replacement decorative Post top lantern 40 Watts with 360º indirect light, system wattage 40 W, Resistance to impact and corrosion, Glare free and better uniformity and making good disturbed surfaces all as specified and directed
M&L for stringing, drawing wiring complete with two run 1.5 sqmm FRLS single core PVC insulated unsheathed single core cable 1100 vots grade, multistranded with copper conductor (ISI Marked) drawn througn PVC conduit with one run of 1.5 sqmm FRLS single core multistranded copper conductor as earth continuity conductor including dismantling unserviceable wiring including accessories complete all as specified and as directed. Note: (1) Two runs of cable & one run of earth continuity conductor shall be measured as one running metre.
M &L for Rigid non-metallic PVC conduit of size 20mm dia inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc on poles, pillars of gate incl taking down old conduits of any size etc all as directed and as specified.
S&F in replacement 40 mm bore, light grade, GI pipe bracket 1.0 mtr long, bend to shape including suitable size nuts, bolts and washers all as directed.
S&F in replacement 32 mm bore, light grade, GI pipe bracket 1.0 mtr long, bend to shape including suitable size nuts, bolts and washers all as directed.
Supply and fix in replacement analog timer switch programmable with 16A current carrying capacity suitable for mounting on DIN rail all as specified and as directed.
Supply and fix in replacement 4 pole contactor 255 A 2 NO +2 NC all as specified and as directed by Eng-in-Charge
Supply and fix in repairs TPN bakelite connector/terminal plate 63A 4 way to be mounted on panel along with connecting cables to the connector all as specified and as directed.
Description all as item 73 herein before but of rating 100A all as specified and as directed.
Disconnecting the existing unserviceable MCCB from panel board after disconnecting cable & supply & fix new MCCB 63A, 4 Pole, 16 KA,adjustable , fixed in existing panel including modification of existing frame and panel board door for proper installation of MCCB and connecting with existing cable including thimble,nut bolt and washers etc complete.
Description all as per item No 75 hereinbefore but of 100A, 4 Pole, 16 KA all as directed and as specified.
Description all as per item No 75 hereinbefore but of 100A, 3 Pole, 16 KA all as directed and as specified.
Disconnecting the existing unserviceable MCCB from panel board after disconnecting cable & Supply & fixing only MCCB 200A, 25 KA 4 Pole fixed in existing panel including modification of existing frame and panel board door for proper installation of MCCB and connecting with existing cable including thimble,nut bolt and washers etc complete.
Description all as item 78 hereinbefore but of 250A, 4 Pole all as directed and as specified.
Description all as item 78 hereinbefore but of 400A, 4 Pole all as directed and as specified.
M&L for detecting cable fault of size upto 240Sqmm LT, XLPE cable by means of fault finding machine / manual including excavation or earth work if required at site and as directed by Enge-in-Charge.
Supply, install, testing and commisioning of CPRI approved outdoor type LT feeder pillar box powder coated at Bde Magazine, suitable for 415V, 3 Phase, 4 wire system, 50Hz, AC supply system,double door, totally enclosed dust & weather/vermin proof made out of 3.15m thick CRCA outer sheet and 2mm inner sheet duly powder coated of suitable size with degree of protection IP 54, floor mounted free standing type, suitable for mounting following switchgear and accessories in the panel alongwith PCC (1:3:6) type C1, bedding upto height of 30cm above ground level complete and taking down existing panel all as directed by Engineer -in- Charge.
OUT GOING: (i) MCCB 100 TPN,16KA-04 Nos (ii) MCB 32 A TPN,10 kA - 2 Nos (iii) MCB 32 A SPN,10 kA - 4 Nos
Material and Labour for preparation of old surfaces of 9 mtr high RCC Poles and applying one coat of cement based paint on RCC poles including painting black and yellow strips of 30 cm each on poles upto 1.0 m from the bottom and numbering with 60mm sized letter with synthetic enamel paint complete all as specified and as directed.
Taking down high mast light fittings mechanically / manually for repair / maintenance and refixing in same position after repair / maintenance such as greasing, winch, motor servicing/ repair, starter repair etc & testing after service complete all as directed.
Taking down carefully, copper/aluminium point wiring (Light, fan, scoket or power)/power point wiring complete,, and making good disturbed surfaces of walls floors, etc.,including complete accessories all as specified and as directed by Engineer-in-Charge.
M&L Point wiring complete with 1.5 sqmm single core FRLS PVC insulated and unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including PVC casing and caping and all accessories fixed to walls / roofs / ceiling etc. and including 1.5 sqmm copper cable FRLS PVC insulated and unsheathed cable 1100 volts as earth continuity conductor and connected to common earth dolly, including fabricated steel terminal box made out of 1.60mm thick MS sheet concealed in walls, with 3mm thick laminated sheet top cover/Pre moulded PVC switch board for housing the switches, socket outlets, fan regulators etc., all as specified and as directed for the following: -
One light point/Bell point/exh fan point controlled by one switch
One fan point controlled by one switch and one regulator
One 3 pin switch socket outlet point 5 amps on same board with other switches.
One light point controlled by two two way switch.
One 3 pin switch socket outlet point 5 amps on independent board.
Material and labour for point wiring with 4 Sqmm FRLS PVC insulated and unsheathed single core stranded copper conductor cable 1100 volts in PVC casing & caping for 2 in one, 3 pin 5 Amps & 15 Amps multi purpose socket on independent board and existing cast iron or pressed steel terminal box with new laminated sheet top cover 3 mm thick, including PVC insulated & unsheathed copper conductor cable 4 Sqmm FRLS PVC insulated and unsheathed cable 1100 volts size for earth continuity conductor and connected to earth dolly including painting to existing sunken boxes with anticorrosive bituminous paint after through cleaning, all as specified and directed.
M&L Point wiring complete with 1.5 sqmm single core FRLS PVC insulated and unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including 20mm dia medium grade rigid non metallic surface PVC conduit and all accessories fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm copper cable green in colour as earth continuity conductor and connected to common earth dolly, including fabricated steel terminal box made out of 1.60mm thick MS sheet concealed in walls, with 3mm thick laminated sheet top cover for housing the switches, socket outlets, fan regulators etc., all as specified and as directed for one light point controlled by one one way switch.
All as per item No. 88 here - in - before but for one fan point controlled by one 5 Amps switch
All as per item No. 88 here - in - before but for 3 pin 5 Amps switch socket combination on independent board.
All as per item No. 88 here - in - before but for 5 Amps switch socket point on the same board controlled by one switch.
Material and labour for point wiring with 4 Sqmm FRLS PVC insulated and unsheathed single core stranded copper conductor cable 1100 volts in PVC medium grade condiut for 2 in one, 3 pin 5 Amps & 15 Amps multi purpose socket on independent board and existing cast iron or pressed steel terminal box with new laminated sheet top cover 3 mm thick, including PVC insulated & unsheathed copper conductor cable 4 Sqmm size FRLS PVC insulated and unsheathed cable 1100 volts for earth continuity conductor and connected to earth dolly including painting to existing sunken boxes with anticorrosive bituminous paint after through cleaning, all as specified and directed.
Material & labour for point wiring as per colour coding with 1.5sqmm FRLS PVC insulated unsheathed stranded copper conductor cable 1100 volt drawn through in and including 19 mm thick rigid non metallic PVC concealed conduit medium quality including new sunken terminal boxes duly epoxy painted and 3mm thick plastic laminated sheet top cover and continuity earth wire PVC insulated copper conductor standard unsheathed of size 1.5sqmm FRLS PVC insulated and unsheathed cable 1100 volts including cutting chases pinning in making good to facings where required and pointing in cement mortar 1:3 ends of edges of landing,steps, cills sunsades,shelves,lintels,etc and cutting for concealed conduit wiring etc and making good,cutting not exc 10 cm girth in brick wall complete for the following all as specified and directed.
One light point/Bell point controlled by one switch
One fan point controlled by one switch and one regulator
One 3 pin switch socket outlet point 5 amps on same board with other switches.
One light point controlled by two two way switch.
One 3 pin switch socket outlet point 5 amps on independent board.
Material and labour for point wiring with 4 Sqmm FRLS PVC insulated and unsheathed single core stranded copper conductor cable 1100 volts in and including PVC concealed conduit medium quality, for 2 in one 3 pin 5Amps & 15 Amps multi purpose socket outlet on independent board and cast iron or pressed steel terminal box duly epoxy painted and with new laminated sheet top cover 3 mm thick concealed in wall including PVC insulated & unsheathed copper conductor cable 4 Sqmm size FRLS PVC insulated and unsheathed cable 1100 volts for earth continuity conductor and connected to earth dolly as per existing all as specified and directed by Engineer-in-Charge.
S&F power / sub main wiring with Three RUNS of single core 4 Sq.mm size (greencolour as earth continuity conductor) PVC insulated , un sheathed , multi stranded copper conductor cables cables drawn through and including PVC casing and capping or non metallic rigid PVC CONDUIT 25/32mm dia and accessories, all conforming to IS specifications, fixed on wall/ceiling / trusses etc., with suitable clamps, screws etc., and connecting up with terminal lugs and taking down of existing unserviceable sub main / power wirings all as specified and as directed
S&F power / sub main wiring with Three RUNS of single core 6 Sq.mm size (greencolour as earth continuity conductor) PVC insulated , un sheathed , multi stranded copper conductor cables cables drawn through and including PVC casing and capping or non metallic rigid PVC CONDUIT 25/32mm dia and accessories, all conforming to IS specifications, fixed on wall/ceiling / trusses etc., with suitable clamps, screws etc., and connecting up with terminal lugs and taking down of existing unserviceable sub main / power wirings all as specified and as directed
M&L for point wiring with two single core 1.5 Sq.mm size multistranded copper conductor PVC insulated cables and one single core 1.5 Sq.mm size green colour PVC insulated,multistranded copper conductor PVC cable as earth continuity conductor,1100 volts grade, complete drawn through existing surface conduit/ concealed in wall / ceiling conduit with suitable clamps , screws etc., including 1.22 mm thick MS terminal boxes with 3 mm thick plastic laminated sheet top cover fixed with cadmium plated iron screws for mounting switches, sockets, fan regulators etc.,including connecting up and test and taking down old wiring all as specified and as directed for the following :-
One light /Exhaust fan point controlled by one switch
One fan point controlled by one switch/and regulator
One switch socket outlet 3 pin 5 Amps on same board along with other switches.
One switch socket outlet 3 pin 5 Amps on independent board.
One bell / buzzer point controlled by one bell push
All as per item No 97 hereinbefore but with two single core 4 Sq.mm size cables and one 1.5 sq.mm green colour cable as earth continuity conductor for one switch socket out let 3 pin 15 Amps on independent board.
S&F power / sub main wiring with Six Runs of single core 6 Sq.mm size (greencolour as earth continuity conductor) PVC insulated , un sheathed , multi stranded copper conductor cables cables drawn in existing suraface /concealed PVC/steel conduit and accessories all conforming to IS specifications and connecting up with terminal lugs and taking down of existing unserviceable sub main / power wirings all as specified and as directed
S&F power / sub main wiring with Three RUNS of single core 4 Sq.mm size (greencolour as earth continuity conductor) PVC insulated , un sheathed , multi stranded copper conductor cables drawn in existing suraface /concealed PVC/steel conduit 25mm dia and accessories, all conforming to IS specifications and connecting up with terminal lugs and taking down of existing unserviceable sub main / power wirings all as specified and as directed
Taking down of fittings and fixtures all as specified and as directed by Engineer-in-Charge.
Supply and fix switch piano flush type single pole one way 5 amps, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix switch socket outlet 3 & 2 pin (mult pin) 5 amps flush/box type, complete all as specified and as dircted by Engineer-in-Charge.
Supply and fix switch socket outlet, 2 in 1, 3 pin 15 and 5 amps, controlled by one switch flush/box type complete all as specified and as directed by Engineer-in-Charge.
Supply and fix ceiling rose surface baklite 65 x 50 mm 3 terminal, complete all as specfified and as directed by Engineer-in-Charge.
Supply and fix lamp holder(angle type) PVC body with back plate suitable for batten fittings, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix bell push single phase, 240 Volts, 50 Hz, complete all as specified and as directed by Engineer-In-Charge.
Supply and fix switch piano flush type single pole two way 5 amps, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix fan speed regulator, electronic suitable for single phase AC, 240 volts, 50 Hz,100 watts, complete all as specified and as directed by Engineer-in-Charge Make:-Anchor/Havells/Bajaj
Supply and fix bell Ding Dong 240 Volts 50 Hz complete all as specified and directed by Engr-in-Charge.
Supply and fix Cordless bell 240 Volts 50 Hz complete all as specified and directed by Engr-in-Charge.
Supply and fixing Modular switch 1 way 5 A, 1 module all as specified and directed.
Supply and fixing Modular switch 1 way 15 A, 1 module all as specified and directed.
Supply and fixing Modular Bell push 5A, 1 module all as specified and directed.
Supply and fixing modular socket outlet, 2/3 pin combined , 6/15 Amps, 2 module, 230 volts all as specified and directed.
Supply and fixing modular fan step regulator, 230 V, AC, 120W - 2 module
Supply and fix in repair metal enclosure distribution board SPN, 8 way 240 volts, with 200 amps rated bus bar, with IP 42 protection and double door, suitable for mounting MCBs, including taking down old MCB/DB, complete all as as specified and as directed by Engineer-in-Charge Make :Indoasian/C&S/Legrand Note:- Incoming & Outgoing connections from the DB shall be provided with proper lugs/thimbles etc...
Supply and fix in repair metal enclosure distribution board SPN, 4 way 240 volts, with 200 amps rated bus bar, with IP 42 protection and double door, suitable for mounting MCBs, including taking down old MCB/DB, complete all as as specified and as directed by Engineer-in-Charge Make Indoasian/C&S/Legrand Note:- Incoming & Outgoing connections from the DB shall be provided with proper lugs/thimbles etc...
Supply and fix sheet metal enclosures Loadline distribution board TPN, 4 ways 415 volts, with 200 amps rated bus bar, with IP 42 protection and double door, suitable for mounting MCBs and in and including 63A MCCB as incomming complete all as specified and as directed including taking down old MCB DBs complete including cutting chases pinning in making good to facings where required and pointing in cement mortar 1:3 ends of edges of landing,steps, cills sunsades,shelves,lintels,etc and cutting for concealed conduit wiring etc and making good,cutting not exc 10 cm girth in brick wall complete all as specified.
Supply and fix in replacement MCCB triple pole and neutral 100 amps 10 KA series complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement MCB single pole and neutral, 240 volts, 6 to 32 amps,10KA,230V, B series complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement MCB single pole 240 volts, 5 to 32 amps,10KA,B series ,230v complete all as specified and as directed by Engineer-in-Charge.
S & F in replacement Single Pole and Neutral Enclosure with Two Pin Earth Plug and Socket complete with one MCB, SP, 20 Amps, 240 Volts all as specified and as directed.
S & F LED light fitting 1 x 7 Watt, podwer coated white finish Star surface 6500k housing round shaped surface mounted LED slim panel with PMMA diffuser including high efficiency electronic driver complete with LED lamp, prewired upto connection block and connecting with three core PVC copper flexible cable of size 1.5 Sq.mm from ceiling rose to connector block, including taking down old unserviceable surface mounted fitting of any wattage, complete all as specified and directed by Engineer-in-Charge.
S & F LED mirror light fitting 1 x 10 Watt provided with high output diffuser including high efficiency electronic driver complete with LED lamp, prewired upto connection block and connecting with three core PVC copper flexible cable of size 1.5 Sq.mm from ceiling rose to connector block, including taking down old unserviceable mirror light fitting of any wattage, complete all as specified and directed by Engineer-in-Charge.
S & F LED tube light fitting 20 Watt, white colour provided with high output diffuser including high efficiency electronic driver complete with LED lamp, prewired upto connection block and connecting with three core PVC copper flexible cable of size 1.5 Sq.mm from ceiling rose to connector block, including taking down old unserviceable wall light fitting of any wattage, complete all as specified and directed by Engineer-in-Charge.
Supply and fix 10 w LED bulk head fitting prewired upto connection block and connecting with three core PVC copper flexible cable of size 1.5 Sq.mm from ceiling rose to connector block, including taking down old unserviceable fitting of any wattage, complete all as specified and directed by Engineer-in-Charge
Supply and fix Recess/surface mounted LED Ultra slim 15 w Round type with in die cast aluminium housing finished in premimum white powder coating prewired upto connection block and connecting with three core PVC copper flexible cable of size 1.5 Sq.mm from ceiling rose to connector block, including taking down old unserviceable fitting of any wattage, complete all as specified and directed by Engineer-in-Charge.
Supply and fix Surface/Recess mounted LED 2x2 Square type 32 w with in die cast aluminium housing finished in premimum white powder coating prewired upto connection block and connecting with three core PVC copper flexible cable of size 1.5 Sq.mm from ceiling rose to connector block, including taking down old unserviceable fitting of any wattage, complete all as specified and directed by Engineer-in-Charge.
Supply and fix ventilating fan suitable for on working of AC 230 V ,50 Hz 200 mm sweep ,including louvers and taking down of unserviceable item complete all as specified
Supply and fix ventilating fan Ventil Air DX whitesuitable for on working of AC 230 V ,50 Hz 250 mm sweep ,incl louvers and taking down of unserviceable item complete all as specified.
Supply and fix Wall mounting fan electric driven single phase230 volts, oscillating type, 400 mm sweep, high quality ABS base with high speed motor and balanced blades and three leafed with 3 core copper cable of suitable size, completeand taking down of unserviceable item all as per specified.
Supply and fix Wall mounting fan Swing, electric driven single phase230 volts, oscillating type, 300 mm sweep, high quality ABS base with high speed motor and balanced blades and three leafed with 3 core copper cable of suitable size, complete and taking down of unserviceable item all as per specified.
Supply and fix exhaust fans electric driven AC single phase 230 volts 300 mm sweep with louvers including grouting and making whole in wall and taking down of unserviceable item complete all as specified.
Supply and fix exhaust fans electric driven AC single phase 230 volts 380 mm sweep with louvers including grouting and making whole in wall and taking down of unserviceable item complete all as specified.
Supply & Fixing in replacement PVC Casing caping of following sizes with accessories like PVC saddles, bend,Tees,Elbow and screws etc.
S & F in replacement Heavy duty PVC Domestic Surface type for Switches of following sizes
(a) 1 Gang Box
(b) 2 Gang Box
(c) 3 Gang Box
(d) 4 Gang Box
(e) 5 Gang Box
(f) 6 Gang Box
(g) 7 Gang Box
Supply and fix in repairs fan condenser 2.5 mfd, AC 440 volts, 50 Hz complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repairs fan condenser 2 mfd, AC 440 volts, 50 Hz complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repairs ceiling fan hanging clamp with bush,locking pin and nut and bolt Including taking down complete all as specified and as directed by Engineer-in-Charge.
Material & labour, earthing complete with galvanize steel earth plate electrode 60 cms x 60 cms x6.00mm thick buried directly in ground vertically to a depth not less than 2.25 meter below ground level with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4.0mm by means of bolts ,nuts ,check nuts and washers of galvanized iron or steel and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron or steel pipe light grade 15 mm bore and water pipe 20 mm bore GI medium grade (ISI marked ) with funnel and wire mesh ,including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No, 5 of MES Sch Part-1 (2009), complete including taking down of existing earthing all as specified and directed.
M&L in replacement Stringing drawing earth continuity wire PVC insulated unsheathed multistranded copper conductor FR/FRLS by opening junction boxes/corner/wall paneling/ fitting/ fixtures etc connecting to common earth point & connecting to earth dolly for following sizes.
(a) 1.5 Sq mm
(b) 4 Sq mm
S&F 1100 Volt grade heavy duty twin core 10 Sq mm of size,(2 core) flat or circular cablePVC PVC tape and over all PVC sheathed as in sevice connections suspended by insulated hangers not more than 1.00 meter apart including 4 mm dia GI suspension wire and taking down old unservicable wire of any type and any size complete all as specified.
M&L for dismantling and removing the U/S plastic laminated sheet top cover of switch boards of any size, supply and fix new plastic laminated sheet top cover 3 mm thick of size as required at site,including necessery cutting to size, cutting / opening and removing/refixing of switches,sockets etc.,drilling holes,replacing screws etc., all as specified and as directed.
Taking out and dismantling the burnt out old winding wire complete and cleaning the internal slots of rotor with ring and rewinding the exhaust fan of size 300mm sweep motor with super enamelled copper winding wire of suitable SWG including varnishing, baking in oven and reassemling refixing at same/ required location, complete all as specified and as directed by Engr-in-Charge.
Description all as per item No 150 above but exhaust fan of 400/450mm sweep
M&L for takind down exhaust fan of any sweep and preparing of old painted surface complete and painting the same with one coat of synthetic enamel paint of existing colour and rewriting of MES No including refixing the exhaust fan in old possition complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repairs condensor 4/3.5 mfd, AC 230 volts, 50 Hz, complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repairs ball bearing suitable for exhaust fan of any sweep and make complete all as specified and as directed by Engr-in-Charge.
Taking down exhaust fan of any size/sweep from existing position complete with blades from brackets etc and servicing the same properly by cleaning, greasing, oiling and refixing in the same position all as specified and as directed by Engr-in-Charge.
Taking down wall mounted fan of any size/sweep from existing position complete with bladesfrom brackets etc and servicing the same properly by cleaning, greasing, oiling and refixing in the same position all as specified and as directed by Engr-in-Charge.
Supply and fix in repairs ball bearing suitable for wall mounted fan of any sweep and make complete all as specified and as directed by Engr-in-Charge.
Taking out and the burnt out old winding wire complete from the wall mounted fan of 400mm sweep and cleaning the internal slots of rotor with ring and rewinding motor with super enamelled copper winding wire of suitable SWG including varnishing, baking in oven and reassemling complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repairs wall mounted fan covering Net
Supply and fix in repairs wall mounted fan blade
Dismantling the burnt out old winding wire complete and cleaning the internal slots of rotor with ring and rewinding with new rotor shaft the ceiling fan of size 1200mm/1400mm sweep motor with super enamelled copper winding wire of suitable SWG including varnishing, baking in oven and reassemling complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repalcement canopy of ceiling fan, complete all as specified and as directed by Engr-in-Charge.
Dismantling and taking down ceiling fan of any size/sweep from existing position complete with blades, down rod and canopy etc and servicing the same properly by cleaning, greasing, oiling after replacing the unservicable spare parts etc, and reassembling and refixing in the same position all as specified and as directed by Engr-in-Charge. (Note: cost of supply and replacement of spare parts shall be measured and paid separately under relevant items of this Schedule.)
Supply and fix in repairs ball bearing suitable for ceiling fan of any sweep and make complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repairs down rod of appropriate size suitable for ceiling fan of any sweep and make complete all as specified and as directed by Engr-in-Charge.
Supply and fix repairs fan blade appropriate size suitable for ceiling fan of any sweep and make complete all as specified and as directed by Engr-in-Charge.
Supply & fix in repairs LED tube rod 20 W complete all as specified and directed by Engineer-in-Charge.
Supply and fix Star surface mounted LED 12 w Round type with in die cast aluminium housing finished in premimum white powder coating prewired upto connection block and connecting with three core PVC copper flexible cable of size 1.5 Sq.mm from ceiling rose to connector block, including taking down old unserviceable fitting of any wattage, complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement MCB three pole and neutral,415 volts, 6 to 32 amps,complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement MCB three pole 415 volts, 5 to 32 amps,complete all as specified and as directed by Engineer-in-Charge.
M&L for Cleaning of following capacity over head reservoir of stagging height upto 30 mtr , semi UG Sumps, Sumps, reservoirs, storage tanks, fountain with deployment of mechanical equipment such as high jet pumps for removal of dirty water, vacuum operated pump for sludge removal, cleaning of inner wall, ceiling and bottom by high pressure rotary jet 120 bar pressure, wet vacuum cleaner etc. complete all as specified and as directed The complete job of the tank cleaning process will be as under:- (i) Mechanical removal of all remaining dirty water by high capacity submersible pump set. (ii) Removal of Sludge by vacuum operated German pump. (iii) Cleaning of walls, ceiling and bottom of tank by German made high pressure rotary jet 120 bar pressure. (iv) Removal of all dirty particles by industrials wet vacuum cleaner leaving the tank physically cleaned. (v) Sterilization of tank by Echo friendly biodegradable and highly effective disinfectant against all pathogenic agents.
Notes :- (i) Contractor must clean and disinfect the water storage tank within 24 hours after giving the site by Engr-in-Charge to avoid the disturbance of water supply to the connected area. (ii) In case of any accident during the work in progress the contractor will be fully responsible to give necessary medical aids and also compensation to worker under compensation act 1923. (iii) No extra payment will be made for transportation of any machineries required for cleaning and disinfection the storage tank. (iv) Water tanks shall be cleaned once in 6 months interval or if any water contamination occures, as per directions of Engr-in-Charge. (v) Contractor must write the date of cleaning and capacity of tank at the wall of the storage tank in size of 2 ft x 2 ft base painted by synthetic enamel paint. Base should be in light blue colour and letters should be white colour without extra payment.
(a) Overhead Tank Reservoir of capacity 10000 Gallon litres
(b) SWT/storage tank of capacity 10000/15000 Litres
Collect the sample of water of 5 litres each from user end,and sending it at Govt approved lab for testing of water as per IS 10500 in a cleaned container and necessary reports should be submitted to GE Birchgunj complete all as directed by Engr in Charge.
M & L for draining out complete water from existing PVC water tank fixed on the roof top of the buildings, removing the mud, sludge etc; from the tank, cleaning the internal surface using bleaching powder and wire brush, keeping it dry, painting the external surfaces of the tank facing the road side with black/white background of size 450mm x 300mm with one coat of approved black/white synthetic enamel paint, writing on the white/black surface with white/black paint " TANK CLEANED ON (date)" size of letter shall be 50mm x 70mm, checking and correcting the air lock on occurrence next day after the cleaning of the tank, when the tank is full of water, removing the same with pump, repair the leakage if any and cleaning the vegetation etc; on surrounding RCC slab where the tank is resting,complete all as specified and directed by Engineer-in-Charge for the following capacity: - Note:- In case of any accident during the work in progress the contractor will be fully responsible to give necessary medical aids and also compensation to workers under compensation act 1923.
(a) Service tank of capacity upto 500 litres
(b) Service tank of capacity exceeding 500 litres but upto 1000 litres
(c) Service tank of capacity 2000 litres
(d) Service tank of capacity 5000 litres
S & F in replacement 20mm dia Ball Valves(float), high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe etc. complete all as specified and as directed
S & F in replacement 25mm dia Ball Valves(float), high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe etc. complete all as specified and as directed
Supply and fix PVC tank cover (top) for rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) suitable for 200/250/500/1000/2000 ltrs capacity, after taking out unserviceable PVC water tank cover complete all as directed by Engineer-in-Charge.
Supply and fix rotational moulded polyethylene water storage tanks 500 Ltrs (cylindrical vertical with closed top) with tank cover (top) hoisted and fixed in position complete after dismantling and taking down the existing unserviceable PVC water tank from terrace/structure etc complete all as directed by Engineer-in-Charge.
All as per item No 177 hereinbefore but of size 1000 ltrs capacity
All as per item No 177 hereinbefore but of size 2000 ltrs capacity
Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5 m deep and getting out for taking out or laying of pipes / cable of any size in Soft/ loose soil complete all as specified and as directed.
S&F in replacement of 20 mm CPVC pipes of pressure rating 10Kgf/sqcm fixed SDR 13.5 grade with all types of fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc) as required at site on walls, ceilings , in floors or in trench etc complete all as specified and directed.
S&F in replacement of 25 mm CPVC pipes of pressure rating 10Kgf/sqcm fixed SDR 13.5 grade with all types of fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc) as required at site on walls, ceilings , in floors or in trench etc complete all as specified and directed.
S&F in replacement of 40 mm CPVC pipes of pressure rating 10Kgf/sqcm fixed SDR 13.5 grade with all types of fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc) as required at site on walls, ceilings , in floors or in trench etc complete all as specified and directed.
S&F in replacement of 50 mm CPVC pipes of pressure rating 10Kgf/sqcm fixed SDR 13.5 grade with all types of fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc) as required at site on walls, ceilings , in floors or in trench etc complete all as specified and directed.
S&F in replacement for union socket of 20mm bore CPVC pipes of pressure rating 10Kgf/sqcm fixed Schedule 80 graded complete all as specified and directed
All as per item No 185 hereinbefore but of size 25mm bore
All as per item No 185 hereinbefore but of size 40mm bore
All as per item No 185 hereinbefore but of size 50mm bore
S&F in replacement for coupler of 20mm bore CPVC pipes of pressure rating 10Kgf/sqcm fixed of Schedule 80 graded complete all as specified and directed
All as per item No 189 but of size 25mm bore
All as per item No 189 but of size 40mm bore
All as per item No 189 but of size 50mm bore
All as per item No 189 but of size 80mm bore
S&F in replacement for Tank connector Moulded of 20mm bore CPVC pipes of pressure rating 10Kgf/sqcm fixed of Schedule 80 graded complete all as specified and directed
All as per item No 194 but of size 25mm bore
All as per item No 194 but of size 40mm bore
S&F in replacement for TEE of 20mm bore CPVC pipes of pressure rating 10Kgf/sqcm fixed of Schedule 80 graded complete all as specified and directed
All as per item No 197 but of size 25mm bore
All as per item No 197 but of size 40mm bore
S&F in replacement for Reducer of 20x15mm bore CPVC pipes of pressure rating 10Kgf/sqcm fixed of Schedule 80 graded complete all as specified and directed
All as per item No 200 but of size 25x20mm bore
All as per item No 200 but of size 40x25mm bore
All as per item No 200 but of size 50x40mm bore
S&F in replacement for Reducing Elbow of 20x15mm bore CPVC pipes of pressure rating 10Kgf/sqcm fixed of Schedule 80 graded complete all as specified and directed
All as per item No 204 but of size 25x20mm bore
S&F in replacement for Elbow of 20mm bore CPVC pipes of pressure rating 10Kgf/sqcm fixed of Schedule 80 graded complete all as specified and directed
All as per item No 206 but of size 25mm bore
All as per item No 206 but of size 40mm bore
All as per item No 206 but of size 50mm bore
All as per item No 206 but of size 80mm bore
S&F in replacement for Reducing bush of 20x15mm bore CPVC pipes of pressure rating 10Kgf/sqcm fixed of Schedule 80 graded complete all as specified and directed
All as per item No 211 but of size 25x15mm bore
All as per item No 211 but of size 25x20mm bore
S&F in replacement for 20mm dia ball valves, Union Type, high pressure, CPVC polythene gate and flynut complete all as specified and as directed.
All as per item No 214 but of size 25mm bore
All as per item No 214 but of size 40mm bore
All as per item No 214 but of size 50mm bore
M&L for CPVC Adhisive solution Gel type of Each 118ml Tin for jointing of CPVC Materials.
S& F in replacement steel water tubes medium grade (ISI marked) galvanised with all fittings laid in trench/ fixed to walls or laid on floor or in ceilings of size 15 mm bore pipe, complete, all as specified and as directed by Engr-in-Charge.
All as per item No 219 above but of size 20 mm dia.
All as per item No 219 above but of size 25 mm dia.
All as per item No 219 above but of size 40 mm dia.
All as per item No 219 above but of size 50 mm dia.
All as per item No 219 above but of size 80 mm dia.
Material and Labour for detecting leakage in GI water supply lines of 80 mm bore in any location, any depth including necessary earthwork excavation and repairing and arresting leakage by providing jointing material, flanged clamps, nuts, M seal ,collor washers & bolts etc,. complete all as specified and as directed.
Material and Labour for detecting leakage in GI water supply lines of 40/50 mm bore in any location, any depth including necessary earthwork excavation and repairing and arresting leakage by providing jointing material, flanged clamps, nuts, M seal ,collor washers & bolts etc,. complete all as specified and as directed.
Material and Labour for detecting leakage in GI water supply lines of 15/20/25 mm bore in any location, any depth including necessary earthwork excavation and repairing and arresting leakage by providing jointing material, flanged clamps, nuts, M seal ,collor washers & bolts etc,. complete all as specified and as directed.
S & F Gun metal gate valve with iron wheel head screwed both ends for iron pipe and fixed complete after dismantling and taking out the existing unserviceable Gun metal gate valve of size 15 mm all as specified and as directed by Engr-in-Charge.
S & F Gun metal gate valve with iron wheel head screwed both ends for iron pipe and fixed complete after dismantling and taking out the existing unserviceable Gun metal gate valve of size 20 mm all as specified and as directed by Engr-in-Charge.
All as per item No 229 above but of size 25 mm.
All as per item No 229 above but of size 40 mm.
All as per item No 229 above but of size 50 mm.
All as per item No 229 above but of size 80 mm.
M & L in replacement of PCC 1:3:6 type CI (using 20mm graded aggregate) as in coping (including necessary form work) complete, all as specified and as directed by Engr-in-Charge.
Supply only PH test Kit including all testing materials
Supply Only Pocket PH Meter (Dual display), Range-0.00 to 14.0 PH, Accuracy +/- 0.1 PH
Supply and fix in replacement GI union socket of 25mm bore medium grade ISI marked.
Supply and fix in replacement GI socket of 25mm bore medium grade ISI marked.
Supply and fix in replacement GI Nipple of 4 Inch size 50mm bore medium grade ISI marked.
Supply and fix in replacement GI Nipple 8 Inch 50mm bore medium grade ISI marked.
Supply and fix in replacement GI elbow of 50mm bore medium grade ISI marked.
Supply and fix in replacement GI reducer socket of 25x20mm bore medium grade ISI marked.
Supply and fix in replacement GI elbow reducer of 25x20mm bore medium grade ISI marked.
Supply and fix in replacement GI Plug of 25mm bore medium grade ISI marked.
Supply and fix in replacement GI Tee of 25mm bore medium grade ISI marked.
M & L for mild steel fabrication work for provision of access to the service water tanks, Ladders for buildings and for valve chamber covers etc with Fe 410 O or Fe-310-0 Gde after dismantling and taking down unserviceable old MS ladder complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of 80 mm CPVC pipes of pressure rating 10Kgf/sqcm fixed SDR 13.5 grade with all types of fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc) as required at site on walls, ceilings , in floors or in trench etc complete all as specified and directed.
M&L for servicing of window type air conditioner of 1/1.5/2.0 Ton capacity any make including, cleaning of air filter, condensing coil and cooling coil with CTC including refixing the unit complete in position all as specified and as directed by Engr-in-Charge.
Dismantling the following unservicable items from window type air conditioner of capacity 1/1.5 /2 Ton of any make and any type and replacing the same with new one including testing and commissioning the same all as specified and as directed by Engr-in-Charge :-
Compressor suitable for 1.5 ton
Compressor suitable for 2 ton
Blower motor single phase, 1/5 hp, 1100 rpm, 130 watts, 240 volts
Over load protector
Thremostat
Starting capacitor 80/100 mfd 230 volts
Running capacitor 36/45 mfd 230 volts
Starting relay
Blower motor fan blade set
Rubber mounting bush for blower motor
S&F in replacement copper condensor coil suitable for 1/1.5/2 T Split/window AC complete all as specified and as directed by Engr-in-Charge.
S&F in replacement copper evaporator coil (cooling ) suitable for 1/1.5/2 T Split/window AC complete all as specified and as directed by Engr-in-Charge.
M&L for servicing of split type air conditioner of 2.0/1.5/1 Ton capacity of any make including, cleaning of air filter, condensing coil and cooling coil with CTC including refixing the unit complete in position all as specified and as directed by Engr-in-Charge.
Dismantling the following unservicable items from split type air conditioner of capacity 1/1.5/2.0 Ton of any make and any type and replacing the same with new one including testing and commissioning the same all as specified and as directed by Engr-in-Charge :-
Compressor for 1/1.5 ton split type air conditioner
Compressor for 2.0 ton split type air conditioner
Oudoor fan motor for 1/1.5 ton split type air conditioner
Oudoor fan motor for 2.0 ton split type air conditioner
Indoor Blower motor for 1/1.5 ton split type air conditioner
Indoor Blower motor for 2.0 ton split type air conditioner
Starting capacitor for 2.0 ton split type air conditioner, 100/120 mfd 230 volts
Starting capacitor for 1/1.5 ton split type air conditioner, 80/100 mfd 230 volts
Running capacitor for 1/1.5 ton split type air conditioner, 36 mfd 230 volts
Running capacitor for 2.0 ton split type air conditioner, 45 mfd 230 volts
Starting relay for 1/1.5/2.0 ton split type air conditioner
PCB Electronic control board for 1.5/2.0 ton split type air conditioner
Insulation rubber hose 12mm for split AC any type
Hand Remote set for 1.5/2.0 ton split type air conditioner
Outer brass valve of size 5/8" for out door unit of split AC 2 ton
Outer brass valveof size 3/8" for out door unit of split AC 2 ton
Outer brass valve of size 1.5" for out door unit of split AC 1.5 ton
Outer brass valve of size 0.25" for out door unit of split AC 1.5 ton
MS Stand for outer unit of split AC 1.5/2 ton capacity.
Expansion valve with capillary for window/split type AC
Dismantling the following unservicable items from water cooler storage type 40/80 cooling of any make and replacing the same with brand new one including testing and commissioning the same all as specified and as directed by Engr-in-Charge :-
Compressor
Fan motor
Thermal over load protector
Starting relay
Thermostat
Starting capacitor 80/100 mfd 230 volts
Running capacitor 10 mfd 230 volts
Self closing tap of chromium plated brass, size 15mm
M&L for charging of refrigerant gas R-134 (a) in Refrigerator/watercooler of any make and type, including testing and commissioning the the equipment, complete all as specified and as directed by Engr-in-Charge.
M&L for charging of refrigerant gas R-22/ R-410/R-32 for Air conditioners of any make and type, including testing and commissioning the the equipment, complete all as specified and as directed by Engr-in-Charge.
M&L for pressure testing the compressor unit including connecting pipe line with nitrogen gas and holding the appropriated pressure for approved period (as per manufactureal instruction) and rectify the leakages by means of welding, soldering/brazing etc for window/splitt type air conditioner/ water cooler/refrigerator of any capacity and make, including testing and commissioning complete all as specified and as directed by Engr-in-Charge.
M&L for preparation of old painted surface of water cooler 40/80 ltrs cooling capacity and painting the same with two coats of synthetic enamel paint over a coat of red oxide primer, including removing corroded portion of steel surfaces and provisions of new mild steel sheet 18 guage fixed in position duly welded and suit the adjoining complete all as specified and as directed by Engr-in-Charge.
M&L for repairing of voltage stabilizer for AC 5/4 KVA capacity , SP 240 volts including replacement of relays and electronic printed circuit board (PCB) with brand new relays & PCBs and testing on completion all as specified and as directed by Engr-in-Charge.
M&L for repairing of voltage stabilizer for AC 0.5 to 3 KVA capacity, SP 240 volts including replacement of relays and electronic printed circuit board (PCB) with brand new relays & PCBs and testing on completion all as specified and as directed by Engr-in-Charge.
S&F in repairs voltage stabilizer 5 KVA capacity AC, SP 240 volts complete all as specified and as directed by Engr-in-Charge.
S&F sheet metal enclosure with industrial type socket with plug top and earth plug and socket complete with one single pole MCB 20 amps 240 volts including taking out old MCB plug and socket complete all as specified and as directed by Engr-in-Charge.
M&L for GI tray for window type AC made out of GI sheet 18 guage thick and including taking out old GI tray, complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repair of PVC conduit 20mm for drain out of air conditioner, complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repair copper tube of size 5/8 with insulation rubber hose, complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repair copper tube of size 1/2 with insulation rubber hose, complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repair copper tube of size 3/8 with insulation rubber hose, complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repair copper tube of size 1/4 with insulation rubber hose, complete all as specified and as directed by Engr-in-Charge.
ICON AGENCIES
KAPOOR AUTOMOBILES
M/S SHAJAHAN BUILDERS
kakolil trade agencies
C KUMAR
M/s.Tarun Construction
SHUSHANT ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .