Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.5 LAccepted-AOC 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹14.9 L+₹2.4 L (19.2%)Rejected-AOC | L2 | Rejected-AOC Not being L1 | |
| 3 | L3₹17.1 L+₹4.5 L (36.4%)Rejected-AOC BX 167 4 ISHWAR NAGAR PATHANKOT PUNJAB 145001 UDYAM PB 16 0001334 03AALFR1593C1ZE B R | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-AOC Not being L1 | |
| 4 | L4₹17.4 L+₹4.8 L (38.7%)Rejected-AOC | L4 | Rejected-AOC Not being L1 | |
| 5 | L5₹19.5 L+₹7.0 L (56.1%)Rejected-AOC | L5 | Rejected-AOC Not being L1 |
Tender Value
₹19 L
EMD Value
₹38,000
Closing Date
21 Mar 2020, 6:00 pmClosed
CWE Pathankot
HQ CWE Pathankot
CWE/P-56/2019-20 SPECIAL REPAIR FOR REPLACEMENT OF CONVENTIONAL SECURITY LIGHTS TO LED LIGHTS INCLUDING ALLIED CABLE SERVICES AT BASOLI MIL STATION UNDER GE BASOLI
2020_MES_327694_1
CWE/P-56/2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Basoli
class E and above Category b i
9 documents required · 9 mandatory
₹500
Yes
GE Basoli
₹38,000
Yes
28 May 2020
22 Feb 2020
23 Mar 2020
22 Feb 2020
21 Mar 2020
7 Mar 2020
Amount
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5mtr in depth for foundation of pole and laying of UG cable and getting out in any type of soil complete all as specified and directed.
Returning filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25cm completed all as specified and directed.
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5M above the starting point completed all as specified and directed.
M&L for PCC ( 1:2:4) type B1 using 20mm graded stone aggregate for coping pedestal of poles. Including necessary form work fair finished to exposed surface completed all as specified and directed.
M&L for PCC ( 1 : 3 : 6 ) type C2 using 40mm graded stone aggreghate for foundation of poles and stay assembly completed all as specified and directed.
Supply & errection of pre stressed concrete pole 9 meters long 102mmx172 mm at top and 102x279mm at bottom class-10 in PCC (1:3:6) type C2 using 40 mm graded stone aggregate in foundation including painting with synthetic enamel paint of colours black and yellow alternate strips of 30cm width upto 1.5 mtr from the top of coping complete including making suitable holes where requiredcomplete all as specified and directed. Note :- Earth work and PCC work shall be paid and measured andpaid seperately
Supply & errection of Steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31 of 9 mtr long in PCC (1:3:6) type C2 using 40 mm graded stone aggregate in foundation including painted with two coats of black bituminous paint internally through out and externaly for embeded portion and painting with one coat of red oxide primer, applying two coats of synthetic enamel aluminium paint on remaining exposed surfaces after errection complete, painting with synthetic enamel paint of colours black and yellow alternate strips of 30cm width upto 1.5 mtr from the top of coping complete including making suitable holes where required complete all as specified and directed. Note :- Earth work and PCC work shall be paid and measured andpaid seperately
Taking down old serviceable PCC/Steel Tubular LT pole of any size any location including earth work and removing/breaking the old PCC in complete and made for reuse and shifting to adjacent location for replanting all as specified and directed.
Errecting of steel tubular/PCC LT pole retrieved against Srl item No 08 here-in-before complete and planted in the earth in PCC (1:3:6) type C2 using 40 mm graded stone aggregate in foundation all as specified and directed. Note :- Earth work and PCC work shall be measured and paid separately.
Dismantling and taking down old existing ACSR conducotr any type from existing HT/LT pole all as specifed and directed
Supply and fixed in replacement aluminium conductor steel re-inforced (ACSR) Ferret of size 6/1x3.00 mm / weasal of size 6/1x2.59 mm and squirrel of size 6/1x2.11 mm for LT lines on concrete poles, stretching without kinks and bends, binding with (rates inclusive) binding wire complete all as specified and directed.
Dismantling of steel work ( brackets,clamps, channels including disc and pin insulators, nut & bolts) from existing pole all as specified and direc ted by Engr-in-Charge.
S&F in structural steel work conforming to grade Fe-410S as in cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections, including , nuts, bolts, washers, welding , bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat , one finishing coat of aluminium paint and epoxy coating, including taking down old corroded structural steel all as directed.
Dismantling insulators any type, any size complete all as specified and directed.
S & F in shackle type,vitreous Insulator incl one galvanised mild steel spindle, two galvanised iron washers,and one galvanised iron nut, 100 mm height, 115 mm dia ,suitable for 1100 Volt,and as directed by engineer in charge.
Dismantling stay assembly complete including demolition of concrete, etc. and necessary excavation as required complete all as specified and directed.
S/F stay assembly complete comprising of 20mm dia 40cm long stay bow rod 20mm dia x 1.8 Mtr long galvanised stay rod threaded and with nuts including 300mmx300mmx6mm thick plate necessary clamps etc as shown on plate No. 1 on page 495 of SSR Part-I, 2009 complete all as specified and directed. Note : Loop type insulator, stay clamp, stay wire, excavation and concrete work measured separately).
Dismantling earth wire or ACSR/stay wire, service feeder or distributor span complete all as specified and directed.
S & F galvanised steel stranded stay wire size 7/4mm for stay assembly complete all as specified and directed.
S & F for galvanised steel wire 4 mm dia all as specified complete all as specified and directed..
S & F loop type insulator iwith complete fiting porcelain, vitreous white or brown large size with over all dismensions 90x140mm , clearance of hole 25.5mm complete all as specified and directed..
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried in ground vertical to a depth not less than 2.25 mtrs deep below ground level with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanized GI wire of size 4 mm dia and 15 mm dia bore 7.5 mtr long light grade GI protection pipe for earth strip and GI watering pipe 40 mm dia medium grade from the top edge of earth plate fixed with deep cut on one end of pipe and fix from earth plate up to one feet above ground level of other end and plugged watering pipe at top with MS cap and grouted in PCC 1:2:4 of size 30 X 30 X 30 CM etc and 15 CM alternate layer of charcoal and salt around all sides of earth plate all shown in electrical plate no. of SSR part I of-2009 complete all as specified and directed.
M&L for painting with two coats of synthetic enamel paint upto 1.5 mtr above the ground level with black and yellow colour alternatively 30 cm interval from bottom of pole of 9 metre RCC/tubular pole including preparation of old treated surface complete all as specified and directed.
M&L for painting of steel tubular pole 9 mtr long in position with two coats of aluminium paint over a coat of red oxide primer after scraping the existing painting surface all as specified.
Taking out the old unsv XLPE/ AB armoured/unarmed cable in trenches or passing through pipe/fixed on pole to pole/wall all as specified and directed.
Supply and Laying in trenches or passing through pipe or fixing to pole/wall UG cable XLPE, of cross section area 50 Sq mm X 3.5 core, PVC insulated,armoured heavy duty electric cable with aluminum conductor,1100 Volts grade complete all as specified and directed. Note :- (I) Earth work/ sand cushioning shall be measured and paid separately .
All as per Srl item no. 26 here-in-before but 25 Sq mm X 3.5 core
All as per Srl item no. 26 here-in-before but 16 Sq mm X 4 core
All as per Srl item no. 26 here-in-before but 16 Sq mm X 2 core
S & F in repairs cable end joint kit for 1100 volt, out door type heat shrinkable type joint complete with all jointing material and accessories suitable for 3.5 core cable of size 25 sq mm to 50 sqmm all as directed.
S&F DWC high density polyethelene pipes in replacement having 63/50outer dia mm, inner as per site requirement having corrugation on the wall and plain surface on the inner wall conforming to IS: 14930(Part I & II) for protection of underground cable laid along pole/along wall/in PCC on GL/roof and including all fittings as required at site including aking down the old unserviceable complete all as specified and directed. Make -Trupati or Equivalent approved by CEWC/E-in-C
Supply & fixing Outdoor panel Fabrication of double and outdoor type incorporated with bus bar chamber having with aluminium busbar capacity 100 amps insulated with RYB & black PVC Insulated tape suitable for 415 Votls 3 Phase 4 wire system 50 c/s fixed on SMC/DMC in step way complete with dust and vermin proof provisions made of CRCA MS Sheet not less than 3.15 mm thick also having provision for incoming/outgoing COS/cables. 02 Nos earth terminal point complete with 10 mm bolt, 02 nos nuts and 02 Nos wahsers 3 mm thick complete earth. The panel body must be painted with power coated paint aftyer the complete 7 tanks dip process to remove all impurities from the panel sheet all the door must be fixed with detachable pin type hinges steel door locking system, all the electrical connection inside the panel from bus bar to MCCBs, shall be through aluminium strip property insulated fixed on SMC/DMC insulators. Panel body shall be fixed on iron angle frame of size 40x40x5 mm 15 cm grouted Leg height 90 CM in PCC 1:2:4 type B 1 using 20 mm graded crushed stone aggregate and 30 cm above the ground level duly painted with two coat of synthetic enamelled balck paint over a coat of red oxide primer all as specified and directed and comprising of the folowing items. (i) MCCB 100 Amps 25 K arating TPN 415 volts- 01 No (In coming)
(ii) MCB TPN 40 Amps 10 KA rating 240 Volts 'C' series -02 Nos (Outgoing) (iii) MCB SPN 63 Amps 10 KA rating (iv) RYB LED Note :- MCCB's shall be fixed in independent position , Main bus bar in step way, the depth of the panel be less than 350 mm , All the rates deemed to be included in the cost of the job. No extra cost shall be paid, before placing the order drawings shall be approved by the GE and shall be kept in record.
S&F in replacment of on laod change over switch in sheet steel enclosure with front handle of capacity 100 Amps, four pole, 415 Volts complete all as specifed and directed.
Taking out old unsv light fitting any type any size all as specified.
Supply and fix in replacment LED street light fitting of capacity 60watt energy saving and environment friendlly long life versatile pressure dia cast aluminium with protection IP 66 and impact resistance of IK07 with high power LEDs as light source with electric chip and driver (Lamp type 60W) including service bracket dia 50 mm galvanised iron pipe medium grade 0.90 metre long complete with provision of double driver and additional surge protector of capacity 10 KV all as specified and directed.
Supply and fix in replacement Energy saving new generation LED flood light fitting powder coated toughfened glass of capacity 120 Watt versatile pressure dia cast aluminium with protection IP 66 and impact resistance of iK 07 with high power LEDs as light source with electric \chip and driver including service bracket made of MS angle 40 x 40 x 5 mm with clamp made of FI 40 x 5 mm with necessary nuts, bolts and washers etc complete with provision of double driver and additonnal surege protector of capacity 10 KV all as specified and directed.
Supply and fix in replacement Energy saving new generation LED flood light fitting powder coated toughfened glass of capacity 80 Watt versatile pressure dia cast aluminium with protection IP 66 and impact resistance of iK 07 with high power LEDs as light source with electric \chip and driver including service bracket made of MS angle 40 x 40 x 5 mm with clamp made of FI 40 x 5 mm with necessary nuts, bolts and washers etc complete with provision of double driver and additonnal surege protector of capacity 10 KV all as specified and directed.
Supply and fix in replacement Energy saving new generation LED flood light fitting powder coated toughfened glass of capacity 60 Watt versatile pressure dia cast aluminium with protection IP 66 and impact resistance of iK 07 with high power LEDs as light source with electric \chip and driver including service bracket made of MS angle 40 x 40 x 5 mm with clamp made of FI 40 x 5 mm with necessary nuts, bolts and washers etc complete with provision of double driver and additonnal surege protector of capacity 10 KV all as specified and directed. Notes for Srl item no 35 to 38: (i) Contractor shall produce LM79 & LM 80 test report from OEM owned NABL accredited laboratory. (ii) Contractor shall give guarantee/ warranty of complete fitting/ fixture for minimum 2 years from the date of completion. (iii) Contractor shall arrange complete material at site for approval of GE before incorporation in the work. (iv) Driver shall be IP 66 degree of protection potted seal type with inbuilt SPD and external SPD of capacity 10 KV to be provided in addition to inbuilt.
Supply and fix out door junction box of size 350X250X150 mm made out of 2 mm thick CRCA sheet powderr coated front hinged door with openable and self closing arrangement incl aluminium bus bar 20 X 5 mm, 3 phase, 4 wire SMD/DMC insulator and cable entry glands for connection and MCB SP 6 Amps - 01 No all as required and fixed to pole with MS clamp made out of MS flate iron of size 25 X 5 mm and including nuts, bolts and washers complete all as specified and directed.
Notes : The Schedule of Credit amount shall be deducted from the total of this schedule(BoQ) to arrive at Contract Sum.
M/S Vijay Punj Constructions
M/S RUDHRAKSH TRADING CO
Ashoka Engineers
Standard engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .