Loading…
Loading…
| # | Company | Amount |
|---|---|---|
| 1 | ₹1.2 Cr |
Tender Value
₹1.6 Cr
EMD Value
₹3.2 L
Closing Date
2 Jun 2026, 3:00 pmClosed
Executive Engineer, Araria
EE
Executive Engineer, Araria Division , BUILDING CONSTRUCTION DEPARTMENT, Araria , Bihar
Superintending Engineer, Purnea Circle
SE
CONSTRUCTION OF CIVIL S.D.O RESIDENCE, FORBESGANJ IN DISTT - ARARIA
131266
02-BCD,ARARIA/2026-27
Open Tender
CIVIL
Araria
• BCD REGISTRATION
• GST REGISTRATION, ELECTRIC LICENCE
• PAN CARD, CHARACTER
• Annual Financial Turnover for Last Three Financial years:-
2023-2024
2024-2025
2025-2026
• Maximum Contract amount for one work of similar nature completed during years:-
2021-2022
2022-2023
2023-2024
2024-2025
2025-2026
• Description
Enter Number of Engineers employed to prove Bidder's Engineering Establishment Available for This Project 10 Type of Technical Staff
1. Civil Engg Degree holder
2. Civil Engg Diploma holder
3. Other Technical Staff / Supervisory Staff
• Description
Name of Plants and Equipment owned by bidder in Working Condition Which will be available at This Work Site 10 Type of Machine
1 Automatic batching plant+accessories
1 Mixer Machine With Weighing Facility
2 Steel shuttering Minimum 2000 Sft
3 Water Tanker
4 Vibrator (Needle and Surface)
• Description
Bank credit and/or Self Declaration submitted / uploaded 5 Particulars
1.Certificate of Bank for credit facility 10
• Description
Necessary undertakings submitted / uploaded 5 UNDERTAKINGS
1. Not abandoned any project
2. Never been in Litigation
3. No relative or any person Working in Department
4. Not Debarred / Blacklisted from any Govt. , PSU Dept.
• Description
Bidding Capacity in Rupees 15 Amount of Existing commitments and ongoing works in Rupees
A= Maximum ATO in Rupees
BID CAPACITY
• ALL OTHER DOCUMENTS AS PER NIT
• 50% similar nature work of total Estimated cost Rs. 16221681.00
CIVIL
PERCENTAGE
L1
1
12 documents required · 12 mandatory
₹10,000
Processing Fee: 3540
₹3.2 L
SE, BCD PURNEA & CE NORTH BCD PATNA PREBID MEETING DATE :-18-05-2026 03:00 pm & 25-05-2026 03:00 PM
23 Sept 2026
11 May 2026
2 Jun 2026
11 May 2026
2 Jun 2026
11 May 2026
18 May 2026
Earthwork in excavation in foundation trenches. do - do all complet job
Extra for every additional lift of 1.5 m or part thereof do - do all complet job
Filling available excavated earth do - do all complet job
Supplaying and filling Local Sand do - do all complet job
Providing 100A B/F soling do - do all complet job
Providing P.C.C (1:2:4) do - do all complet job
Extra for Providing and mixing water proofing material do - do all complet job
Providing and laying in position mixed design mix M-25 grade up to Plinth do - do all complet job
Providing and laying in position mixed design mix M-25 grade up in Column do - do all complet job
Centring and Shuttering in foundation do - do all complet job
Centring and Shuttering in Shelves do - do all complet job
Centring and Shuttering in roof do - do all complet job
Centring and Shuttering in Beam do - do all complet job
Centring and Shuttering in Column do - do all complet job
Weather shade,Chajjas, corbels etc. including edge
Edges of slabs and breaks in floors and wall
Brick work CM (1:6) with fly ash bricks in foundations and plinth do - do all complet job
Brick work CM (1:6) with fly ash bricks in foundations and plinth do - do all complet job
Extra for providing and placing in position 2 Nos, 6 mm dia , MS barsat every third course of half brick masonry (with F. P. S. bricks)
Providing and fixing 35 mm thick flush door. do - do all complet job
Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete asper manufacturer’s specification and direction of Engineer-in-chargeExtruded section profile size 42x50 mm
25 mm thick PVC flush door shutters made out of a one piece Multi chamber extruded PVC section of the size of 762mm X 25 mm or less as per requirement with an average wall thickness of 1 mm (± 0.3 mm). PVC foam end cap of size 23x10 mm are provided on both vertical edges to ensure the overall thickness of 25 mm. An M.S. tube having dimensions 19 mm x 19 mm and 1.0 mm (± 0.1 mm) is inserted along the hinge side of the door. Core of the door shutter should be filled with High Density Polyurethane foam. The Top & Bottom edges of the shutter are covered with an end-cap of the size 25mm X 11 mm. Door shutter shall be reinforced with special polymeric reinforcements as per manufacturer’s specification and direction of Engineer-incharge to take up necessary hardware and fixtures. Stickers indicating the locations of hardware will be pasted at appropriate places.
Extra for Providing lipping 2nd class teak wood battens do - do all complet job
Providing and fixing upvc sliding do - do all complet job
Providing and fixing brass curtain rods of wall thickness 1.25 mm with two brass brackets fixed with brass screws and wooden plugs etc.
Providing and fixing pressed steel door frame do - do all complet job
Providing and fixing stainless steel railling do - do all complet job
Providing and fixing M.S grill for window do - do all complet job
Providing and laying ceramic glazed floor tiles (300 x 300 mm) do - do all complet job
Providing and fxing ceramic glazed wall tiles do - do all complet job
Providing and laying kota stone flooring do - do all complet job
Providing and fixing kota stone skarting do - do all complet job
Providing and laying vitrifed floor tiles (60 x 60 cm) do - do all complet job
Providing and laying vitrifed floor tiles Skrting (60 x 60 cm) do - do all complet job
Providing and fixing 18 mm thick gang saw cut do - do all complet job
Providing edge moulding to 18 mm thick marble stone counters,vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
Stone tile work for wall lining do - do all complet job
Providing 12 mm CP (1:6) do - do all complet job
Providing 15 mm CP (1:4) do - do all complet job
Providing 6 mm CP (1:4) Ceiling do - do all complet job
Providing and applaying white cement based putty do - do all complet job
Distempering with oil bound washable distemper do - do all complet job
Applying priming coat ready mixed wood primer do - do all complet job
Applying priming coat ready mixed steel primer do - do all complet job
Painting with synthetic enamel paint do - do all complet job
Froming groove of uniform 12 x 12 mm do - do all complet job
Providing 12 mm CP (1:3) finished with floating coat cement do - do all complet job
Finishing wall with acrylic smooth exterior paint do - do all complet job
Providing and laying integral cement based water proofing treatment. do - do all complite job
Extra covering top of membrane do - do all complet job
Cement concrete flooring 1:2:4(1 cement:2 coarse:sand:4 do - do all complet job
Providing and fixing Heat Resistant terrace tiles (300 x 300 x 20) mm do - do all complet job
Providing Plinth Protection 750 mm wide do - do all complet job
Supplying chemical emulsion in sealed containers including delivery as specified do - do all complet job
Diluting and injecting chemical emulsion for Along external wall do - do all complet job
Diluting and injecting chemical emulsion for Along external wall do - do all complet job
Providing 250 mm wide brick drain do - do all complet job
Providing & Fixing 18 mm thick pre-laminated cement bonded wood particle
Providing & Fixing 6 mm thick pre-laminated cement bonded wood particle
Supplyingand fixing-rollingshuters of approvedmake, 80x1.25mmM.S. Laths with 1.25mm thick top cover.
Bricks
Coarse Sand
Stone Chips
Local Sand
Cement
Bricks
Providing and placing on terrace (at all floor levels) polythylene water storage ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS : 8931
Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.
Excavating trenches of required width for pipes, cables etc. Including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5M including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering, etc.And disposing of surplus excavated soil as directed within a lead of 50 m Hard/dense soil.
Providing, laying Non pressure NP2 class (light duty) RCC Pipes with collars jointed with stiff mixture of cement mortar in the propoertion of 1:2 (1 cement : 2 fine sand) including testing and jointing etc complete.
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement andmaking channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
Extra for depth for manholes
Supplying and fixing in vertical position in bore well, uPVC medium well casing (CM) pipe do - do all complet job
2.5 mm2 Cable
Providing R.C.C M-20 (1:1:5:3) do - do all complet job
Slab/ roof
Earthwork in excavation in foundation trenches. do - do all complet job
Brick work CM (1:6) in foundations and plinth. do - do all complet job
Brick work CM (1:4) with fly ash bricks in foundations and plinth. do - do all complet job
Rough cast plaster with a mixture of sand and gravel or crushed stone do - do all complet job
Providing 12 mm CP (1:4) do - do all complet job
Providing net cement punning do - do all complet job
Providing well burnt brick bats & jhama do - do all complet job
Grassing with 'Doob' grass including watering and maintenance ofthe lawn for 30 days or more tili the grass forms a thick lawn freeform weeds and fit for mowing including supplying good earth ifneeded.In rows 5 cm apart in either direction.
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20 % 1 part of stacked volume of manure after reduction by 8 % ) flooding with water, dressing including removal of rubbish and surplus earth, if any with all leads and lifts (cost of manure sludge or extra good earth if needed to be paid for separately)
Cast in Situ Cement Concrete M 20 Kerb with Channel (Construction of cement concrete kerb with channel with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M15 grade foundation 150 mm thick, kerb channel 300 mm wide, 50 mm thick in PCCM20 grade, sloped towards the kerb, kerb stone with channel laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 409). PCC M20 for Kerb Cast in situ
Providing and fixing M.S. grills of required pattern in frames ofwindows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/
painting
Providing 15mm CP in cm (1:6) on rough side of single or half brick wall with clean coarse sand etc all complete job as per building specification & direction of E/I.
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in Cement mortar 1:6 (1 cement: 6 coarse sand ). Extra tor Brick work in superstructure above plinth level upto floor V cum.
Providing designation 100 A one brick on edge soling joints filled withlocal sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of E/l
Excavating, supplying and filling of local earth (including royalty but excluding cairriage cost) by mechanical transport upto a lead of 3km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. If local earth is available at more than 3 km lead the actual lead must be approved by compitent authority. cairraiage of material will be paid seperately and calculated after deducting initial lead
Preparation and consolidation of sub grade with power road roller of8 to 12 tonne capacity after excavating earth to an average of 22.5cm depth, dressing to camber and consolidating with road rollerincluding making good the undulations etc. and re-rolling the subgrade and disposal of surplus earth with lead upto 50 metres
Construction of granular sub-base by providing close gradedMaterial conforming to specifications, mixing in a mechanical mixplant at OMC, carriage of mixed material by tippers to work site, forall leads & lifts, spreading in uniform layers of specified thicknesswith motor grader on prepared surface and compacting withvibratory power roller to achieve the desired density, complete asper specifications and directions of Engineer-in-Charge.With material conforming to Grade-I (size range 75mm to 0.075 mm) having CBR Value-30
Providing and laying C.C. pavement of mix M-25 with ready mixedconcrete from batching plant. The ready mixed concrete shall be laidand finished with screed board vibrator , vacuum dewateringprocess and finally finished by floating, brooming with wire brush etc.complete as per specifications and directions of Engineer-incharge.(The panel shuttering work shall be paid for separately).(Note:- Cement content considered in this item is @ 330 kg/cum.Excess/less cement used as per design mix is payable/ recoverableseparately).
Wiring for light point/ fan point/ exhaust fan point/ Call bell Point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit with modular switch, modular Plate, suitable size G.I box etc. as required.
Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size of G.I. box with modular plate and cover in front or in surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 25 amps modular socket outlet and 25 amps modular SP MCB 'C' curve, including connections, painting etc. as required. (for AC terminal)
Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 4 nos. 5 pin 5/6 amps modular socket outlet and 4 nos. 5/6 amps modular switch, connection etc. as reqd. (for computer terminal)
Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 2 nos. 5 pin 5/6 amps modular socket outlet and 2 nos. 5/6 amps modular switch, connection etc. as reqd.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Supply and drawing the following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
Supplying and fixing following way, horizontal type three pole & neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar,neutral bus bar,earth bar, din bar, inerconnections, powder painted including earthing etc. as reqd.(But without MCB/RCCB/Isolator)
Supplying and fixing following rating, 240/415 volts, ‘C’ curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing of following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc.as required.
Supplying and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley internal wiring, earth terminals, Bus bar Chamber, Insulator and complete in all respect etc and panel manufacturers must be approved by CPRI. (But without RYB inicator , ammeter, voltmeter, inter-connection copper conductor cable / solid copper strip, switchgears etc.
Providing and fixing following capacity four pole ON-load/ panel mounted changeover switches inside the existing cubical panel board including drilling holes in cubicle panel, making connections etc. as required.
Supplying and fixing following rating, 240/415 volts, ‘C’ curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying of copper strip of all sizes for busbar strip/interconnection including drilling holes etc as reqd.
Suppy and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc. as required.
Supply of following sizes and core PVC / XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
Supplying and fixing 2 pin, 5/6 amp. ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing batten/ angle holder including connection etc. as required.
Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required.
Supplying and fixing electronic musical call bell suitable for single phase, 230 volts complete as required.
Supplying and fixing 4' X 18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required.
Supplying and fixing surface mounted following types LED downlighter with minimum efficacy 100 lm/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, IP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required.
Supplying and fixing of 32 mm dia X 1.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV/ HPSV/ LED street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
supplying and fixing modular blanking plate on the existing modular plate & switch box but excluding modular plate as required.
Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 210 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required.
Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing & fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required.
Supplying Installation, Testing and Commissioning of on-grid Solar Photovoltaic Power Plant conforming to various applicable standards BIS, IEC, MNRE guidelines, the Central Electricity Authority Regulations and CPWD Specifications as amended up to date, consisting of Mono/Poly Crystalline silicon solar cells module, net metering facility, necessary control, protections, earthing, cabling, mounting structure, junction boxes, power conditioning units, Real time online web interfaced Data Monitoring System, Distribution panels, grid connecting arrangement, conduits, pipes, cable trays and other accessories etc. as required. a) High Energy Efficiency Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730- Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 23% at STC with temperature coefficient of Pmax better than -0.30% per 0C. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Solar Modules shall be designed to operate in relative humidity upto 100% with temperature between -10 0C and +85 0C. Further, each PV module used in any solar power project must have Radio frequency identification tag with information such as name of manufacturer, month and year of manufacturing, country of origin (separately for Solar cell and module), I-V curve, Unique Serial No and Model No of the module, Wattage, Im, Vm and FF, name of test lab issuing IEC certificate.
SOR. NO.
Earthwork in excavation in foundation trenches. do - do all complet job
Extra for every additional lift of 1.5 m or part thereof do - do all complet job
Filling available excavated earth do - do all complet job
Supplaying and filling Local Sand do - do all complet job
Providing 100A B/F soling do - do all complet job
Providing P.C.C (1:2:4) do - do all complet job
Extra for Providing and mixing water proofing material do - do all complet job
Providing and laying in position mixed design mix M-25 grade up to Plinth do - do all complet job
Providing and laying in position mixed design mix M-25 grade up in Column do - do all complet job
Centring and Shuttering in foundation do - do all complet job
Centring and Shuttering in Shelves do - do all complet job
Centring and Shuttering in roof do - do all complet job
Centring and Shuttering in Beam do - do all complet job
Centring and Shuttering in Column do - do all complet job
Weather shade,Chajjas, corbels etc. including edge
Edges of slabs and breaks in floors and wall
Brick work CM (1:6) with fly ash bricks in foundations and plinth do - do all complet job
Brick work CM (1:6) with fly ash bricks in foundations and plinth do - do all complet job
Extra for providing and placing in position 2 Nos, 6 mm dia , MS barsat every third course of half brick masonry (with F. P. S. bricks)
Providing and fixing 35 mm thick flush door. do - do all complet job
Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete asper manufacturer’s specification and direction of Engineer-in-chargeExtruded section profile size 42x50 mm
25 mm thick PVC flush door shutters made out of a one piece Multi chamber extruded PVC section of the size of 762mm X 25 mm or less as per requirement with an average wall thickness of 1 mm (± 0.3 mm). PVC foam end cap of size 23x10 mm are provided on both vertical edges to ensure the overall thickness of 25 mm. An M.S. tube having dimensions 19 mm x 19 mm and 1.0 mm (± 0.1 mm) is inserted along the hinge side of the door. Core of the door shutter should be filled with High Density Polyurethane foam. The Top & Bottom edges of the shutter are covered with an end-cap of the size 25mm X 11 mm. Door shutter shall be reinforced with special polymeric reinforcements as per manufacturer’s specification and direction of Engineer-incharge to take up necessary hardware and fixtures. Stickers indicating the locations of hardware will be pasted at appropriate places.
Extra for Providing lipping 2nd class teak wood battens do - do all complet job
Providing and fixing upvc sliding do - do all complet job
Providing and fixing brass curtain rods of wall thickness 1.25 mm with two brass brackets fixed with brass screws and wooden plugs etc.
Providing and fixing pressed steel door frame do - do all complet job
Providing and fixing stainless steel railling do - do all complet job
Providing and fixing M.S grill for window do - do all complet job
Providing and laying ceramic glazed floor tiles (300 x 300 mm) do - do all complet job
Providing and fxing ceramic glazed wall tiles do - do all complet job
Providing and laying kota stone flooring do - do all complet job
Providing and fixing kota stone skarting do - do all complet job
Providing and laying vitrifed floor tiles (60 x 60 cm) do - do all complet job
Providing and laying vitrifed floor tiles Skrting (60 x 60 cm) do - do all complet job
Providing and fixing 18 mm thick gang saw cut do - do all complet job
Providing edge moulding to 18 mm thick marble stone counters,vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
Stone tile work for wall lining do - do all complet job
Providing 12 mm CP (1:6) do - do all complet job
Providing 15 mm CP (1:4) do - do all complet job
Providing 6 mm CP (1:4) Ceiling do - do all complet job
Providing and applaying white cement based putty do - do all complet job
Distempering with oil bound washable distemper do - do all complet job
Applying priming coat ready mixed wood primer do - do all complet job
Applying priming coat ready mixed steel primer do - do all complet job
Painting with synthetic enamel paint do - do all complet job
Froming groove of uniform 12 x 12 mm do - do all complet job
Providing 12 mm CP (1:3) finished with floating coat cement do - do all complet job
Finishing wall with acrylic smooth exterior paint do - do all complet job
Providing and laying integral cement based water proofing treatment. do - do all complite job
Extra covering top of membrane do - do all complet job
Cement concrete flooring 1:2:4(1 cement:2 coarse:sand:4 do - do all complet job
Providing and fixing Heat Resistant terrace tiles (300 x 300 x 20) mm do - do all complet job
Providing Plinth Protection 750 mm wide do - do all complet job
Supplying chemical emulsion in sealed containers including delivery as specified do - do all complet job
Diluting and injecting chemical emulsion for Along external wall do - do all complet job
Diluting and injecting chemical emulsion for Along external wall do - do all complet job
Providing 250 mm wide brick drain do - do all complet job
Providing & Fixing 18 mm thick pre-laminated cement bonded wood particle
Providing & Fixing 6 mm thick pre-laminated cement bonded wood particle
Supplyingand fixing-rollingshuters of approvedmake, 80x1.25mmM.S. Laths with 1.25mm thick top cover.
Bricks
Coarse Sand
Stone Chips
Local Sand
Cement
Bricks
Providing and placing on terrace (at all floor levels) polythylene water storage ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS : 8931
Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.
Excavating trenches of required width for pipes, cables etc. Including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5M including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering, etc.And disposing of surplus excavated soil as directed within a lead of 50 m Hard/dense soil.
Providing, laying Non pressure NP2 class (light duty) RCC Pipes with collars jointed with stiff mixture of cement mortar in the propoertion of 1:2 (1 cement : 2 fine sand) including testing and jointing etc complete.
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement andmaking channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
Extra for depth for manholes
Supplying and fixing in vertical position in bore well, uPVC medium well casing (CM) pipe do - do all complet job
2.5 mm2 Cable
Providing R.C.C M-20 (1:1:5:3) do - do all complet job
Slab/ roof
Earthwork in excavation in foundation trenches. do - do all complet job
Brick work CM (1:6) in foundations and plinth. do - do all complet job
Brick work CM (1:4) with fly ash bricks in foundations and plinth. do - do all complet job
Rough cast plaster with a mixture of sand and gravel or crushed stone do - do all complet job
Providing 12 mm CP (1:4) do - do all complet job
Providing net cement punning do - do all complet job
Providing well burnt brick bats & jhama do - do all complet job
Grassing with 'Doob' grass including watering and maintenance ofthe lawn for 30 days or more tili the grass forms a thick lawn freeform weeds and fit for mowing including supplying good earth ifneeded.In rows 5 cm apart in either direction.
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20 % 1 part of stacked volume of manure after reduction by 8 % ) flooding with water, dressing including removal of rubbish and surplus earth, if any with all leads and lifts (cost of manure sludge or extra good earth if needed to be paid for separately)
Cast in Situ Cement Concrete M 20 Kerb with Channel (Construction of cement concrete kerb with channel with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M15 grade foundation 150 mm thick, kerb channel 300 mm wide, 50 mm thick in PCCM20 grade, sloped towards the kerb, kerb stone with channel laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 409). PCC M20 for Kerb Cast in situ
Providing and fixing M.S. grills of required pattern in frames ofwindows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/
painting
Providing 15mm CP in cm (1:6) on rough side of single or half brick wall with clean coarse sand etc all complete job as per building specification & direction of E/I.
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in Cement mortar 1:6 (1 cement: 6 coarse sand ). Extra tor Brick work in superstructure above plinth level upto floor V cum.
Providing designation 100 A one brick on edge soling joints filled withlocal sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of E/l
Excavating, supplying and filling of local earth (including royalty but excluding cairriage cost) by mechanical transport upto a lead of 3km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. If local earth is available at more than 3 km lead the actual lead must be approved by compitent authority. cairraiage of material will be paid seperately and calculated after deducting initial lead
Preparation and consolidation of sub grade with power road roller of8 to 12 tonne capacity after excavating earth to an average of 22.5cm depth, dressing to camber and consolidating with road rollerincluding making good the undulations etc. and re-rolling the subgrade and disposal of surplus earth with lead upto 50 metres
Construction of granular sub-base by providing close gradedMaterial conforming to specifications, mixing in a mechanical mixplant at OMC, carriage of mixed material by tippers to work site, forall leads & lifts, spreading in uniform layers of specified thicknesswith motor grader on prepared surface and compacting withvibratory power roller to achieve the desired density, complete asper specifications and directions of Engineer-in-Charge.With material conforming to Grade-I (size range 75mm to 0.075 mm) having CBR Value-30
Providing and laying C.C. pavement of mix M-25 with ready mixedconcrete from batching plant. The ready mixed concrete shall be laidand finished with screed board vibrator , vacuum dewateringprocess and finally finished by floating, brooming with wire brush etc.complete as per specifications and directions of Engineer-incharge.(The panel shuttering work shall be paid for separately).(Note:- Cement content considered in this item is @ 330 kg/cum.Excess/less cement used as per design mix is payable/ recoverableseparately).
Wiring for light point/ fan point/ exhaust fan point/ Call bell Point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit with modular switch, modular Plate, suitable size G.I box etc. as required.
Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size of G.I. box with modular plate and cover in front or in surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 25 amps modular socket outlet and 25 amps modular SP MCB 'C' curve, including connections, painting etc. as required. (for AC terminal)
Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 4 nos. 5 pin 5/6 amps modular socket outlet and 4 nos. 5/6 amps modular switch, connection etc. as reqd. (for computer terminal)
Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 2 nos. 5 pin 5/6 amps modular socket outlet and 2 nos. 5/6 amps modular switch, connection etc. as reqd.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Supply and drawing the following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
Supplying and fixing following way, horizontal type three pole & neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar,neutral bus bar,earth bar, din bar, inerconnections, powder painted including earthing etc. as reqd.(But without MCB/RCCB/Isolator)
Supplying and fixing following rating, 240/415 volts, ‘C’ curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing of following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc.as required.
Supplying and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley internal wiring, earth terminals, Bus bar Chamber, Insulator and complete in all respect etc and panel manufacturers must be approved by CPRI. (But without RYB inicator , ammeter, voltmeter, inter-connection copper conductor cable / solid copper strip, switchgears etc.
Providing and fixing following capacity four pole ON-load/ panel mounted changeover switches inside the existing cubical panel board including drilling holes in cubicle panel, making connections etc. as required.
Supplying and fixing following rating, 240/415 volts, ‘C’ curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying of copper strip of all sizes for busbar strip/interconnection including drilling holes etc as reqd.
Suppy and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc. as required.
Supply of following sizes and core PVC / XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
Supplying and fixing 2 pin, 5/6 amp. ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing batten/ angle holder including connection etc. as required.
Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required.
Supplying and fixing electronic musical call bell suitable for single phase, 230 volts complete as required.
Supplying and fixing 4' X 18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required.
Supplying and fixing surface mounted following types LED downlighter with minimum efficacy 100 lm/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, IP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required.
Supplying and fixing of 32 mm dia X 1.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV/ HPSV/ LED street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
supplying and fixing modular blanking plate on the existing modular plate & switch box but excluding modular plate as required.
Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 210 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required.
Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing & fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required.
Supplying Installation, Testing and Commissioning of on-grid Solar Photovoltaic Power Plant conforming to various applicable standards BIS, IEC, MNRE guidelines, the Central Electricity Authority Regulations and CPWD Specifications as amended up to date, consisting of Mono/Poly Crystalline silicon solar cells module, net metering facility, necessary control, protections, earthing, cabling, mounting structure, junction boxes, power conditioning units, Real time online web interfaced Data Monitoring System, Distribution panels, grid connecting arrangement, conduits, pipes, cable trays and other accessories etc. as required. a) High Energy Efficiency Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730- Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 23% at STC with temperature coefficient of Pmax better than -0.30% per 0C. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Solar Modules shall be designed to operate in relative humidity upto 100% with temperature between -10 0C and +85 0C. Further, each PV module used in any solar power project must have Radio frequency identification tag with information such as name of manufacturer, month and year of manufacturing, country of origin (separately for Solar cell and module), I-V curve, Unique Serial No and Model No of the module, Wattage, Im, Vm and FF, name of test lab issuing IEC certificate.
aoc.json
Purchase Order
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
e- NIT 02.pdf
NIT • 1.51 MB
EVALUATIONSHEETNIT10.pdf
NIT • 3.92 MB
e- NIT 02.pdf
NIT • 1.51 MB
PAPER CUTTING.pdf
NIT • 0.46 MB
NIT Construction of Civil S.D.O Residence, Forbesganj in District-Araria NIT-02.doc
NIT • 0.07 MB
BOQ Residance OK.xlsx
NIT • 0.15 MB
BOQ Residance OK.xlsx
NIT • 0.15 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .