Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.0 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹26.2 L+₹28,000 (1.08%)Rejected-Finance 256 MODEL TOWN AMBALA CITY 134003 | AMBALA CITY | AMBALA | HARYANA | 134003 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹29.5 L+₹3.6 L (14.0%)Rejected-Finance FLAT NO A 402 SHANKAR HEIGHTS NEAR CHETANA SCHOOL HAJI MALANG ROAD KALYAN EAST THANE MUMBAI 421 306 | THANE | MAHARASHTRA | 421306 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹29.7 L+₹3.8 L (14.8%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹30.9 L+₹5.0 L (19.5%)Rejected-Finance SHOP NO 5 OPP SHANI MANDIR PROFESSOR COLONY DISTT YAMUNA NAGAR HARYANA 135001 | YAMUNANAGAR | HARYANA | 135001 | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹63,800
Closing Date
24 Aug 2021, 6:00 pmClosed
GE UTILITY
GE UTILITY AMBALA CANTT 133001
SPL REPAIRS FOR REPLACEMENT OF CI GI PIPE LINES INTO DI CI IN OLD PANIPAT LINE OF JCOs OR QTRS UNDER GE U AMBALA CANTT
2021_MES_462970_1
CA No GE U AMB 31 OF 2021-22
Open Tender
Civil Works
Item Rate
240 days
AMBALA CANTT
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE UTILITY AMBALA CANTT
₹63,800
Yes
3 Sept 2021
27 Jul 2021
26 Aug 2021
27 Jul 2021
24 Aug 2021
10 Aug 2021
27 Jul 2021 - 7 Aug 2021
Amount
Excavation in trenches not exc 1.50 metre wide not exc 1.50 metre deep in soft/ loose soil for laying of pipe line and getting out complete all as specified and directed by Engineer-in-Charge..
Returning filling in, including spreading leveling, watering and well ramming in layers not exc 25 cm all as specified and as directed by Engineer in Charge..
Removal of excavated soil surplus to the requirement to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point
Taking up/down corroded/unserviceable GI pipes 150mm dia and connection from trenches incl connected fittings/accessories complete and removing the U/S pipes from site all as directed by Engr-in-charge:-
Taking up/down corroded/unserviceable GI pipes 100mm dia and connection from trenches incl connected fittings/accessories complete and removing the U/S pipes from site all as directed by Engr-in-charge.
Taking up/down corroded/unserviceable GI pipes 50mm dia and connection from trenches incl connected fittings/accessories complete and removing the U/S pipes from site all as directed by Engr-in-charge.
Taking up/down corroded/unserviceable GI pipes 40 mm dia and connection from trenches incl connected fittings/accessories complete and removing the U/S pipes from site all as directed by Engr-in-charge.
Taking up/down corroded/unserviceable GI pipes 25 mm dia and connection from trenches incl connected fittings/accessories complete and removing the U/S pipes from site all as directed by Engr-in-charge.
Taking up/down corroded/unserviceable GI pipes 20 mm dia and connection from trenches incl connected fittings/accessories complete and removing the U/S pipes from site all as directed by Engr-in-charge.
Supply and laying Ductile iron pipe 150 mm dia, S/S,Class K- 9, ISI marked complete all as specified and directed.
Supply and laying Ductile iron pipe 100 mm dia, S/S,Class K- 9, ISI marked complete all as specified and directed.
Supply, laying & testing in trenches GI pipe, 50 mm dia medium grade ISI marked with all fittings complete all as specified and directefd.
Supply, laying & testing in trenches GI pipe, 40 mm dia medium grade ISI marked with all fittings complete all as specified and directefd.
Supply, laying & testing in trenches GI pipe, 25 mm dia medium grade ISI marked with all fittings complete all as specified and directefd.
Supply, fixing & testing on wall or laid under floor GI pipe 25 mm dia medium grade ISI marked with all fittings complete all as specified nd directefd.
Supply, fixing & testing on wall or laid under floor GI pipe 20 mm dia medium grade ISI marked with all fittings complete all as specified nd directefd.
Supply and fixing cast iron sluice valve PN-1.6 with flanged ends 150 mm nominal bore ISI marked complete with gun metal or stainless steel spindle and cast iron cap including rubber /fiber boared gasket nuts, washers etc including taking down old unserviceable sluice valves complete all as specified and as directed by Engineer-in-Charge.
Description all as per item 16 here inbefore but 100 mm bore.
Description all as per item 16 here inbefore but 80 mm bore.
Supply and fixing gun metal gate valve ISI marked with iron wheel screwed down high pressure screwed both ends for iron pipe of size 50mm bore complete all as specified and directed by Engineer-in-Charge.
Description all as per item 11 here in before but 40mm bore.
Description all as per item 11 here in before but 25mm bore.
Description all as per item 11 here in before but 20mm bore.
Taking out old/unserviceable float valve and supply & fixing PVC float valves high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule of 20mm bore complete all as specified and directed by Engineer-in-Charge.
Material and labour for rubber gasket(Tyton) joints suitable for 100 mm bore DI pipe and fittings including jointing material complete all as specified and directed by Engineer-in-Charge.
Material and labour for rubber gasket(Tyton) joints suitable for 150 mm bore DI pipe and fittings including jointing material complete all as specified and directed by Engineer-in-Charge.
Supply and fixing cast iron fitting for spigot and socket /flanged pipe such as bends (any type radius and angle) tapers any type ( straight, bends, increasing, decreasing or double socket etc) Tee pieces single branch, 'Y' junction, double branch , cross collers , caps and plugs upto 150 mm bore complete all as directed by Engineer-in-Charge.
M&L for PCC 1:3:6 type C-2 using 10mm graded mechanically crushed stone aggregate as in bed of channel foundation filling /Panel bedding and mass concrete complete all as specified and as directed.
Note :- Amount of credit of Rs. 292400.00 for retrieved materials is mentioned in Schedule of Credit mentioned in tender documents in pdf form which will be deducted offline while acceptance of tender.
M/S SHANTI CONSTRUCTION
Gupta Enterprises
BAL SINGH & SONS
JS CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .