| Sl No | Description | Qty | Unit | A.K.ENTERPRISES L3 | FCP INDIA L2 | ENGINEERING SALES & SERVICE CORPORATION L1 | CLASSIC ENTERPRISE L4 |
|---|---|---|---|---|---|---|---|
| 1.00Hydrostatic Testing of Fire Extinguishers : | |||||||
| 1.01 | Hydrostatic testing of fire extinguishers shall be carried out. The scope includes collection, safe transportation, complete discharge of the extinguisher, dismantling, internal inspection, hydrostatic pressure testing using calibrated equipment, drying, reassembly, and affixing of test certificate/tag indicating date of testing and next due date.
Any cylinder found defective, leaking, or failing the pressure test shall be rejected and replaced only after approval of the Engineer-in-Charge. All tools, equipment, and safety precautions shall be the responsibility of the contractor. | 342 | Nos | 50 ₹17,100 Lowest | 200 ₹68,400 | 75 ₹25,650 | 200 ₹68,400 |
| 2.00Annual Maintenance of Fire Extinguishers for the period of three (3) years : | |||||||
| 2.01 | Annual Maintenance Contract (AMC) for the existing fire extinguishers installed at CSIR-IICB, Jadavpr and Salt Lake campus for the period of three (3) years. The work shall include periodic inspection, checking of pressure, seals, hoses, nozzles, safety pins, and overall condition of the extinguishers.
The contractor shall carry out quarterly inspections and maintain proper service records/logbooks. Minor repairs, replacement of defective parts (excluding cylinder replacement), lubrication, and ensuring readiness of extinguishers at all times are included in the scope. Breakdown/emergency calls shall be attended as and when required basis.
All servicing shall be carried out by trained personnel, and service tags/stickers indicating the date of service and next due date shall be affixed on each extinguisher. | 392 | Nos | 147 ₹57,624 Lowest | 275 ₹1,07,800 | 216 ₹84,672 | 480 ₹1,88,160 |
| 3.00Refilling of Fire Extinguishers (ABC powder, CO₂, Dry Powder, Water, Foam, Clean Agent etc.) [Existing 392 nos FE and additional 53 nos FE as & when require basis)] The scope includes collection, safe transportation, complete discharge, cleaning, refilling with specified quantity and type of extinguishing media, pressurization, leakage testing, and reinstallation at site. New safety seals and discharge hoses (if required) shall be provided. Each refilled extinguisher shall be properly labelled with details of refilling date, next due date, and agency name. Test certificates shall be submitted to the Engineer-in-Charge. | |||||||
| 4.00Refilling of ABC type (MAP 50% concentration (Mono Ammonium Phosphate (MAP)), powder-based fire extinguishers, including complete discharge of existing contents, internal cleaning, and removal of old chemical/powder. The work shall include thorough inspection/health check-up of the cylinder, valve, hose, and other components, and Refilling shall be done with approved quality MAP 50% ABC dry chemical powder conforming to relevant BIS standards. The item also includes supply of all necessary materials, accessories, nitrogen gas pressurization, sealing, and fixing of discharge hose (if required), complete in all respects. Proper service tags indicating date of refilling and next due date shall be affixed. The warranty of the refilled chemical/powder shall be for a minimum period of 03 (three) years from the date of refilling. | |||||||
| 4.01 | 1 Kg ABC type
[Existing 40 nos FE and additional 4 nos FE (as & when require basis)] | 44 | Nos | 259 ₹11,396 | 110 ₹4,840 | 25 ₹1,100 Lowest | 160 ₹7,040 |
| 4.02 | 2 Kg ABC type
[Existing 2 nos FE and additional 1 nos FE (as & when require basis)] | 3 | Nos | 315 ₹945 | 170 ₹510 | 50 ₹150 Lowest | 275 ₹825 |
| 4.03 | 4 Kg ABC type
[Existing 86 nos FE and additional 9 nos FE (as & when require basis)] | 95 | Nos | 426 ₹40,470 | 330 ₹31,350 | 100 ₹9,500 Lowest | 350 ₹33,250 |
| 4.04 | 5 Kg ABC type
[Existing 2 nos FE and additional 1 nos FE (as & when require basis)] | 3 | Nos | 482 ₹1,446 | 370 ₹1,110 | 125 ₹375 Lowest | 390 ₹1,170 |
Tender Value
₹5.2 L
EMD Value
₹10,384
Closing Date
2 Jul 2026, 5:00 pmClosed
Administrative Officer, CSIR - IICB, Kolkata
CSIR-Indian Institute of Chemical Biology 4, Raja S. C. Mullick Road, Jadavpur, Kolkata-700032
Refilling, Servicing, and hydrostatic testing for the period of three (3) years at CSIR-IICB, Jadavpur and Salt Lake Campus.
2026_CSIR_276640_1
CSIR_IICB / Admn 26(936) / E / 2025 (2nd call)
Open Tender
Miscellaneous Works
Item Rate
1095 days
CSIR-IICB, Jadavpur and Salt Lake campus
As per NIT
4 documents required · 4 mandatory
₹0
₹10,384
Yes
CSIR-IICB, Jadavpur campus
17 Jul 2026
2 Jun 2026
3 Jul 2026
2 Jun 2026
2 Jul 2026
23 Jun 2026
16 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Hydrostatic Testing of Fire Extinguishers : | |||||
| 1.01 | Hydrostatic testing of fire extinguishers shall be carried out. The scope includes collection, safe transportation, complete discharge of the extinguisher, dismantling, internal inspection, hydrostatic pressure testing using calibrated equipment, drying, reassembly, and affixing of test certificate/tag indicating date of testing and next due date.
Any cylinder found defective, leaking, or failing the pressure test shall be rejected and replaced only after approval of the Engineer-in-Charge. All tools, equipment, and safety precautions shall be the responsibility of the contractor. | 342 | Nos | - | - |
| 2Annual Maintenance of Fire Extinguishers for the period of three (3) years : | |||||
| 2.01 | Annual Maintenance Contract (AMC) for the existing fire extinguishers installed at CSIR-IICB, Jadavpr and Salt Lake campus for the period of three (3) years. The work shall include periodic inspection, checking of pressure, seals, hoses, nozzles, safety pins, and overall condition of the extinguishers.
The contractor shall carry out quarterly inspections and maintain proper service records/logbooks. Minor repairs, replacement of defective parts (excluding cylinder replacement), lubrication, and ensuring readiness of extinguishers at all times are included in the scope. Breakdown/emergency calls shall be attended as and when required basis.
All servicing shall be carried out by trained personnel, and service tags/stickers indicating the date of service and next due date shall be affixed on each extinguisher. | 392 | Nos | - | - |
| 3Refilling of Fire Extinguishers (ABC powder, CO₂, Dry Powder, Water, Foam, Clean Agent etc.) [Existing 392 nos FE and additional 53 nos FE as & when require basis)] The scope includes collection, safe transportation, complete discharge, cleaning, refilling with specified quantity and type of extinguishing media, pressurization, leakage testing, and reinstallation at site. New safety seals and discharge hoses (if required) shall be provided. Each refilled extinguisher shall be properly labelled with details of refilling date, next due date, and agency name. Test certificates shall be submitted to the Engineer-in-Charge. | |||||
| 4Refilling of ABC type (MAP 50% concentration (Mono Ammonium Phosphate (MAP)), powder-based fire extinguishers, including complete discharge of existing contents, internal cleaning, and removal of old chemical/powder. The work shall include thorough inspection/health check-up of the cylinder, valve, hose, and other components, and Refilling shall be done with approved quality MAP 50% ABC dry chemical powder conforming to relevant BIS standards. The item also includes supply of all necessary materials, accessories, nitrogen gas pressurization, sealing, and fixing of discharge hose (if required), complete in all respects. Proper service tags indicating date of refilling and next due date shall be affixed. The warranty of the refilled chemical/powder shall be for a minimum period of 03 (three) years from the date of refilling. | |||||
| 4.01 | 1 Kg ABC type
[Existing 40 nos FE and additional 4 nos FE (as & when require basis)] | 44 | Nos | - | - |
| 4.02 | 2 Kg ABC type
[Existing 2 nos FE and additional 1 nos FE (as & when require basis)] | 3 | Nos | - | - |
| 4.03 | 4 Kg ABC type
[Existing 86 nos FE and additional 9 nos FE (as & when require basis)] | 95 | Nos | - | - |
| 4.04 | 5 Kg ABC type
[Existing 2 nos FE and additional 1 nos FE (as & when require basis)] | 3 | Nos | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.83 MB
TDFE1.pdf
Tender Documents • 2.87 MB
BOQ_323115.xls
BOQ • 0.35 MB
FElist.pdf
Additional Documents • 0.48 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .