Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.3 LAccepted-Finance B 11 SCHOOL ROAD UTTAM NAGAR NEW DELHI DELHI 110059 UDYAM DL 11 0049695 | WEST DELHI | DELHI | 110059 | ₹21.3 L | L1 | Accepted-Finance Found in Order |
| 2 | L2₹21.6 LRejected-Finance GROUND FLOOR F 11 PHASE II MAYAPURI WEST DELHI DELHI 110064 | DELHI | WEST DELHI | DELHI | 110064 | ₹21.6 L | L2 | Rejected-Finance Not Found in Order |
| 3 | L3₹22.5 LRejected-Finance HOUSE NO 95 STREET NO 08 JAWAHAR COLONY NEAR LAXMI DAIRY FARIDABAD SECTOR 22 HARYANA 121005 | FARIDABAD | HARYANA | 121005 | ₹22.5 L | L3 | Rejected-Finance Not Found in Order |
| 4 | L4₹23.9 LRejected-Finance 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | ₹23.9 L | L4 | Rejected-Finance Not Found in Order |
| 5 | L5₹25.6 LRejected-Finance M 78 GARU HARKISHAN NAGAR PASCHIM VIHAR NEW DELHI 110087 | NEW DELHI | WEST DELHI | DELHI | 110087 | ₹25.6 L | L5 | Rejected-Finance Not Found in Order |
| Sl No | Description | Qty | Unit | M/S ANIL KUMAR L7 | RND ENGINEERS & CONTRACTORS L3 | AMIT ENTERPRISES L2 | M P TYAGI ENGINEERS AND CONTRACTORS L4 | RS GREEN INDIA CONSTRUCTION L6 | M/s Naresh Kumar Gupta & Co. L1 | SALUJA CONSTRUCTION CO L5 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Labour only for attending day to day external water supply complaints of all nature i.e leakage in water supply pipe lines, fitting/fixture, over flow of overhead tank, no water supply,taking out water from trenches during repair including noting the complaints in complaint register complete all as directed by Engineer-in-charge. (Any material required for attending complaints shall be measured and paid separately under respective item herein after) | 800 | EACH JOB | 29 ₹23,200 Lowest | 58 ₹46,400 | 70 ₹56,000 | 99 ₹79,200 | 110 ₹88,000 | 89 ₹71,200 | 49 ₹39,200 |
| 2.00 | Labour only for attending day to day electric supply complaints of day to day mantenance of existing LT Panels involving replacement of meterials including connecting electrical accessories / spares of water supply installation from 0830 hrs to 1730 hrs and electrical fitting & light, short circuits in pump house including nothing the complaints from Nodal Point No. I and allied areas in complaints register and distribution to the trademen complete all as directed (any meterial required for atteding complaints shall be measured & paid seperately under respective item here after)
Note:- The suitable shift duites as deems fit shall be decision of the Engr-in-charge | 400 | EACH JOB | 39 ₹15,600 Lowest | 58 ₹23,200 | 75 ₹30,000 | 99 ₹39,600 | 110 ₹44,000 | 89 ₹35,600 | 49 ₹19,600 |
| 2.01Notes for Item No 1.01 & 1.02 :- (i) The complaints shall be attended and the defects shall be rectified by a team of expert and experienced electrician/plumber as applicable assisted with adequate No of helpers complete all as specified and as directed. (ii) The complaints shall be attended and defect shall be rectified within 08 hrs commencing from date and time of notifying the complaint failing which a penalty @ Rs 500/- per complaint per day (08 hrs) shall be levied upon/imposed on the contractor and recovery shall be made from contractor's dues.Contractor rep shall be available wef 0800 hrs to 2000 Hrs to receive and notify the complained (iii) In case, after checking and attending the defect, it is not possible to rectify the defects within 08 hrs the facts shall be brought to the notice of Engineer-in -charge by the contractor /his rep . If Engineer -in-charge is satisfied with contractors view, no recovery will be made. (iv) While attending the complaint of water supply /Electric supply if earth work is required then the same shall be measured and paid seperately under appropriate item of Sch 'A' . However no extra payments shall be made for dewatering. (v) Cutting of GI pipe in position and threading is also deemed to be included in the job rate (Fitting and fixtures will be measured and paid separetely under respective item of Sch A. (vi) All T & P as well as dewatering motor single phase of 3HP with including 100 mtr cable, required for attending the complaints shall be provided by the contracor. (vii) The pipe fitter shall always be in possession of die set complete with cutters , boring Tups , Pipe wrench, Chain wrench,Caulking tools, set of spanners and ladders,wehicle/Ricksha etc Complete,all as required at site. | ||||||||||
| 2.02(viii) The elecrician shall always be in possession of all Electrician tools , LT Megger, Earth tester , Multimeter , Crimping tool, insulation tape, Hand gloves etc complete all as required at site and directed by Engr-in-charge. (ix) All material reqd at site for day to day maintenance shall be issued by Deptt under respective items here in after. | ||||||||||
| 3.00Supply only the following items :- | ||||||||||
| 4.00GI Socket Med Grade ,ISI marked of following Size:- | ||||||||||
| 4.01 | 15 mm bore | 25 | EACH | 15 ₹375 | 8 ₹200 | 5 ₹125 Lowest | 99 ₹2,475 | 30 ₹750 | 8 ₹200 | 10 ₹250 |
| 4.02 | 20mm bore | 40 | EACH | 15 ₹600 | 10 ₹400 | 7 ₹280 Lowest | 99 ₹3,960 | 35 ₹1,400 | 10 ₹400 | 12 ₹480 |
| 4.03 | 25mm bore | 40 | EACH | 15 ₹600 | 13 ₹520 | 9 ₹360 Lowest | 99 ₹3,960 | 35 ₹1,400 | 12 ₹480 | 15 ₹600 |
| 4.04 | 40mm bore | 10 | EACH | 15 ₹150 | 18 ₹180 | 15 ₹150 | 99 ₹990 | 40 ₹400 | 14 ₹140 Lowest | 20 ₹200 |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
11 Mar 2026, 6:00 pmClosed
GE U WATER SUPPLY DELHI CANTT 10
GE U WATER SUPPLY DELHI CANTT 10
PETTY REPAIR FOR ATTENDING DAY TO DAY EM EXTERNAL WATER SUPPLY AT DK PART II AND ELECTRICAL COMPLAINTS AT NODAL POINT NO I AND PUMP HOUSES AND CONNECTED AREAS OF AGE U WS No III UNDER GE U WATER SUPPLY DELHI CANTT 10
2026_MES_752278_1
GE/WS/Token No-76 OF 2025-26
Open Tender
Civil Works
Item Rate
270 days
GE U WATER SUPPLY DELHI CANTT 10
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE U WATER SUPPLY DELHI CANTT 10
₹99,000
Yes
27 Mar 2026
11 Feb 2026
13 Mar 2026
11 Feb 2026
11 Mar 2026
26 Feb 2026
Labour only for attending day to day external water supply complaints of all nature i.e leakage in water supply pipe lines, fitting/fixture, over flow of overhead tank, no water supply,taking out water from trenches during repair including noting the complaints in complaint register complete all as directed by Engineer-in-charge. (Any material required for attending complaints shall be measured and paid separately under respective item herein after)
Labour only for attending day to day electric supply complaints of day to day mantenance of existing LT Panels involving replacement of meterials including connecting electrical accessories / spares of water supply installation from 0830 hrs to 1730 hrs and electrical fitting & light, short circuits in pump house including nothing the complaints from Nodal Point No. I and allied areas in complaints register and distribution to the trademen complete all as directed (any meterial required for atteding complaints shall be measured & paid seperately under respective item here after) Note:- The suitable shift duites as deems fit shall be decision of the Engr-in-charge
Notes for Item No 1.01 & 1.02 :- (i) The complaints shall be attended and the defects shall be rectified by a team of expert and experienced electrician/plumber as applicable assisted with adequate No of helpers complete all as specified and as directed. (ii) The complaints shall be attended and defect shall be rectified within 08 hrs commencing from date and time of notifying the complaint failing which a penalty @ Rs 500/- per complaint per day (08 hrs) shall be levied upon/imposed on the contractor and recovery shall be made from contractor's dues.Contractor rep shall be available wef 0800 hrs to 2000 Hrs to receive and notify the complained (iii) In case, after checking and attending the defect, it is not possible to rectify the defects within 08 hrs the facts shall be brought to the notice of Engineer-in -charge by the contractor /his rep . If Engineer -in-charge is satisfied with contractors view, no recovery will be made. (iv) While attending the complaint of water supply /Electric supply if earth work is required then the same shall be measured and paid seperately under appropriate item of Sch 'A' . However no extra payments shall be made for dewatering. (v) Cutting of GI pipe in position and threading is also deemed to be included in the job rate (Fitting and fixtures will be measured and paid separetely under respective item of Sch A. (vi) All T & P as well as dewatering motor single phase of 3HP with including 100 mtr cable, required for attending the complaints shall be provided by the contracor. (vii) The pipe fitter shall always be in possession of die set complete with cutters , boring Tups , Pipe wrench, Chain wrench,Caulking tools, set of spanners and ladders,wehicle/Ricksha etc Complete,all as required at site.
(viii) The elecrician shall always be in possession of all Electrician tools , LT Megger, Earth tester , Multimeter , Crimping tool, insulation tape, Hand gloves etc complete all as required at site and directed by Engr-in-charge. (ix) All material reqd at site for day to day maintenance shall be issued by Deptt under respective items here in after.
Supply only the following items :-
GI Socket Med Grade ,ISI marked of following Size:-
15 mm bore
20mm bore
25mm bore
40mm bore
50mm bore
GI Elbow Med Grade, ISI marked of following Size:-
15 mm bore
20mm bore
25mm bore
40mm bore
50mm bore
GI Union Med Grade ,ISI marked of following Size:-
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
GI Nipple of different length as per requirement, both end screwed Medium Grade, ISI marked of following size:-
15 mm bore
20mm bore
25mm bore
40mm bore
50mm bore
PVC 'L' type Holder, Aluminium rod,Float Ball etc all as required at site and all as directed of following Size:-
15 mm bore
20mm bore
25mm bore
40mm bore
50mm bore
Gi Reducing socket medium grade isi marked to following sizes
25 mm x 15 mm bore
20 mm x 15 mm bore
25 mm x 20 mm bore
50 mmx 40mm bore
GI solid plug heavy duty isi marked to following sizes
15 mm bore
20mm bore
25mm bore
40mm bore
50mm bore
GI TEE of different length as per requirement, both end screwed Medium Grade, ISI marked of following size:-
15 mm x 15 mm x 15 mm
20 mm x 20 mm x 20 mm
25 mm x 25 mm x 25 mm
40 mm x 40 mm x 40 mm
50 mm x 50 mm x 50 mm
GI reducing TEE of different length as per requirement, both end screwed Medium Grade, ISI marked of following size:-
20 mm x20mmx15mm
25 mmx25mmx15mm
25 mmx25mmx20mm
40 mmx40mmx15mm
40 mmx40mmx20mm
40 mmx40mmx25mm
50 mmx50mmx15mm
50 mmx50mmx20mm
50 mmx50mmx25mm
50 mmx50mmx40mm
Supply and laying tubing GI pipe medium grade ISI marked including all fittings in old/new position in trenches/ wall/ floor including taking out as directed of following sizes :-
15mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Supply only of Lead Pig bar of standard quality inclosed container complete all as specified and directed.
Supply only Spun Yarn of best quality in bundles complete all as specified and directed.
Supply only Lead Wool
Supply only Nuts, Bolts and Washers 25 to 150 mm long of 6 to 20 mm dia complete all as specified and as directed.
Supply only PTMT Float valve with epoxy coated aluminium rod and high density HDPE ball of following sizes complete all as specified.
15 mm bore dia
20 mm bore dia
25 mm bore dia
40 mm bore dia
50 mm bore dia
Supply only gun metal gate/ball valve with iron wheel head screwed both ends for iron pipe , ISI marked , as per IS : 778 of following sizes complete all as specified.
15 mm bore dia
20 mm bore dia
25 mm bore dia
40 mm bore dia
50 mm bore dia
Supply only Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms/20mm-125gms). complete all as specified and as directed.
15 mm bore dia
20 mm bore dia
Opening the existing Sluice Valve including opening of gland cover taking out with stem nut of brass or of stainless steel & refixing the same after with & incluiding replacement of rubber packing, nut & bolts, glands dori, etc complete all as specified and directed of following sizes. (Note :- Spare parts under relevant items shall be measured and paid separately under repsiective items)
80 mm bore
100 mm bore
150 mm bore
250 mm bore
Supply only 'stem nut' made out from stainless steel of sluice valve of following sizes, complete all as specified and as directed.
80 mm bore
100 mm bore
150 mm bore
250 mm bore
Supply only 'Gland Plate' made out from Cast Iron suitable to match with existing sluice valve, sizes as under, complete all as specified and as direct
80 mm bore
100 mm bore
150 mm bore
250 mm bore
Taking up or down CI/DI/MS Pipe of following sizes including all fittings) with spigot and socketed ends and lead tyton joints including burning out lad joints and recovering lead and including cleaning for refixing or removal complete all as specified and as directed. Note:- Excavation & earth work shall be measured & paid separetely.
100 mm bore
150 mm bore
200 mm bore
100mm bore
150 mm bore
200 mm bore
Material and labour for Rubber Gasket Joint (tyton joint) including jointing material for DI/CI pipe of following sizes, complete as specified.
100 mm bore
150 mm bore
200 mm bore
Labour for cutting of existing CI / DI pipe for insertion of CI specials etc. all as required including dewatering of lekage water all as required of the following size complete all as specified and as directed .
100 mm bore
150 mm bore
200 mm bore
Supplying of DI/CI MJ collar of the following sizes:-
100 mm bore
150 mm bore
200 mm bore
250 mm bore
300 mm bore
400 mm bore
Supplying & Fixing, jointing and testing of cast iron Sluice Valve ISI marked (PN-1.0) confirming to IS 14846-2000, flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and gaskets complete all as specified.
80 mm bore pipe
100 mm bore pipe
150 mm bore pipe
200 mm bore pipe
250 mm bore pipe
Supplying & Fixing , jointing and testing in replacement of existing unservicableof cast iron NRV ISI marked (PN-1.6) confirming to IS 5312, flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and gaskets complete all as specified.
80 mm bore dia pipe
100 mm bore dia pipe
150 mm bore dia pipe
200 mm bore dia pipe
S&F in replacement three Pole Power Contactor 25 Amp 415/440 volts 50 HZ type ML 1.5 or MNX Type range 25 Amps complete all as specified and directed
S&F in replacement three Pole Power Contactor 32 Amp 415/440 volts 50 HZ type ML 2 or MNX Type range 40 Amps complete all as specified and directed
S&F in replacement Bimetal Over load relay for ML 1.5 or MNX Type with range 9-14 Amp complete all as specified and directed
S&F in replacement Bimetal Over load relay for ML 2 or MNX Type with range 13-21 Amp complete all as specified and directed
S&F in replacement Bimetal Over load relay for ML 3 or MNX Type with range 20-32 Amp complete all as specified and directed
S&F in replacement of FASD ML-1.5/MN 16 Type with relay range 9-15 Amps complete all as specified and directed
S&F in replacement of FASD ML-2.0/MN 25 Type with relay range 14-23 Amps complete all as specified and directed
Supply and fix in replacement of 3 Pole MCCB, 63 Amp, 50 Hz, 415 V with rupturing capacity 16 KA complete all as specified and directed
Supply and fix in replacement of 3 Pole MCCB, 100 Amp, 50 Hz, 415 V with rupturing capacity 16 KA complete all as specified and directed
Supply and fix in replacement of 4 Pole MCCB, 160 Amp, 50 Hz, 415 V with rupturing capacity 36 KA complete all as specified and directed
S&F in replacement moulded case circuit breakers 4 pole 400 Amps having breaking capcity 36 KA at 415 volts complete all as specified and directed
Supply and fixing in replacement of GM ball valve of sizes 12 mm dia bore including coolling pipe with check nuts, suitable length of GI nipples etc complete for Centrifugal Pump Sets complete all as specified and directed.
Supply and fixing in replacement Pressure gauge of suitable pressure upto 14 Kgs/cum all as existing including necessary fitting, complete all as specified and directed.
Testing of drinking water being collected from local source (bore wells/shallow wells/under ground sumps) in the area under AGE(U) W/S No III and submission of detailed test reqport to the office of Engineer-in-Charge. (a) Collection of water from different sources of water ie Sump, bore wells & shallow wells in sterilized bottle for testing of water of different sources from Govt Approved laboratory as mentioned in PS. (b) Carrying out minimum essential testing of water as per IS 10500-1991 mandatory for chemical colour, odour, taste, turbidity, Lead, PH value TDS total hardness, iron, chloride, fluride and residual free chlorine and Bacteriological total Collie from organisms per 100 ml (MPN) and E Collie in 100 ml) and submission the test report to EIC and after ward the same will be submit by EIC to AO with their specific recommendation regarding suitability of water for drinking purpose.
S&F modular switch, 06 Amps, single pole, one way, 230 volts, one module and IP 20 protection complete all as specified & directed
S&F modular switch, with indicator, 16 Amps, single pole, one way, 230 volts complete all as specified & directed
S&F modular socket outlet 05 Pin, 06 Amps, 02 module with shutter complete all as specified & directed
S&F modular socket outlet 2 in 1, 5 pin, 16 Amps, flush type, 230 volts with socket frame complete all as specified & directed
S&F ceiling fan regulator, stepped type of 0 to 04 rotary steps, electronic, 02 module, humfree, AC, 230 volts, 120 watts incl connection complete all as specified & directed
S&F in repairs LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed
PVC insulation tape role of length 10 M
PVC adhisive tape role of length 10 M
Supply only Ceiling rose 3 terminal PVC/Polycarbonate, isolated body 230 volt
Supply only MCB of following sizes:-
SP 6 to 32 Amp, 240 volts 'c' curve
SPN 40 Amp , 240 volts 'c' curve
Supply and fixing in repair copper terminals lugs (Thimbles) ring type medium duty for following sizes :-
Supply and fixing in repair Aluminium terminals lugs (Thimbles) ring type medium duty for following sizes :-
Supply and laying LT XLPE UG armoured , heavy duty electric cable with aluminium conductor, 1100 volts grade, of cross siectional area of following sizes including taking down the existing XLPE cable one and deposited to MES store yard all as directed:- (Note :- (a) Excavation & earth work brick protection & sand cushioning shall be measured and paid seperately under respective items. (b) Layout plant shall be given by Engineer-in-Charge to contractor in writing.
16 Sqmm, 4 core
35 Sqmm, 3.5 core
50 Sqmm, 3.5 core
70 Sqmm, 3.5 core
M/L for sand filling in cable ducts/ trenches with and including removing old sand to a distance not exceeding 50 mtr away and depositing where directed by Engineer-in-charge.
Supply and fixing in repair connecting and testing new generation energy saving & environmental friendly long life versatile pressure die cast aluminium IP-66 roadway luminaire 60 Watt LED with high power LED as light source suitable for pole/wall dia 63 mm (max) inlcuding making connection with three core PVC insulated and sheathed copper conductor cable of size 1.5 Sqmm complete all as specified and directed
Supply and fixing in replacement connecting and testing new generation energy saving & environmental friendly long life versatile pressure die cast aluminium IP-66 roadway luminaire 35 Watt LED with high power LED as light source suitable for pole/wall dia 63 mm (max) inlcuding making connection with three core PVC insulated and sheathed copper conductor cable of size 1.5 Sqmm complete all as specified and directed
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexiblecopper conductor cable of suitable size from ceiling rose complete.
Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and directed.,
S&F in replacement of Water Level Indicator (Mechinical type)at semi under ground water reserviors including providing greasing the pully, including adjustment of steel rope/float ball for its proper calibration and replacement of existing unserviceable nut and bolt, pully, float ball and steel rope making functional for its smooth effecient functioning complete all as specified and directed. Note:- Float ball and steel rope shall be measured and paid for seperately.
Supply and fixing steel rope stranded (flexible 3 mm dia complete all as specified and directed as per sample).
Suply and fixing in replacement of Brass ball of size 300 mm bore complete with suitable size u clamps for manual water level indicator coplete all as specified and as directed
Surface Excavation not exceeding 30 cm deep averaging 15 cm deep for cleaning the area by cutting the unwanted bushes/vegitation growth in and around the area of installation/around the valve pit chamber/along the pipe line routes etc and getting out soft/loose soil, all as specified and as directed at site by Engineer-in-Charge.
Earthing complete with galvanised steel earth plate ectrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to using galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
Supply and laying of rubber insulated mat of size 2.00 mtr x 1.00 mtr of 19 mm thick ISI marked complete all as specified and as directed by Engr-in-charage.
Supply and fixing rotational moulded polyethylene water storage tank, cylindrical vertical with closed top, 500 litres capacity, tripple layered, hoisted and fixed in position after taking down as existing at site (of any capacity) complete all as specified and as directed..
Supply and fixing rotational moulded polyethylene water storage tanks, cylindrical vertical with closed top, 1000 litres capacity, tripple layered, hoisted and fixed in position after taking down as existing at site (of any capacity) complete all as specified and as directed..
Material and labour for SS works of grade 304 any shape/sizes of angles irons/flat iron/MS sheet/circuler etc including necessary cutting and welding, works, and writing works (Flesheet) of suitable size of writting complete all as specified and directed by Engr-in-charge.
Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth for pipe line, etc in soft/ loose soil getting out and levelling of bottom surface to required level all as specified and as directed.
Returning filling, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick all as specified and as directed by the Engineer-in-charge.
Removing excavated material from site to a distance not exc 50mtr away and depositing where directed not exc 1.5mtr from the starting point complete all as specified and directed.
Supply & laying of Sub Class 'B' brick laid across the cable above the sand cushioning for protection of cable complete all as specified and directed
M&L Brick work with sub class 'B' old size bricks straight or curved on plan exceeding 6 m mean radious built in cement mortar 1:6 complete all as specified and directed
M & L PCC (1:3:6) type C2 using 40mm graded crushed stone aggregate as in foundation for including fair finish even and fair to exposed surfaces without using extra cement complete all as specified and as directed
M&L Machine pressed precast concrete interlocking paverblocks any shape and size confirming to IS 15658-2006 of 60 mm thick, M-40 Grade with grey cement and no pigments, over 25 mm thick sand cushioning including taking down existing pavers and deposited to store yard complete all as specified and as directed.
Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 1100 volts LT cables of different sizes from both ends, removal of fault & reconnection and testing of cables after removal of fault complete all as specified and directed by Engr-in-charge. NOTE: (a) 1100 volt cables and joints shall be measured and paid for seperately under respective items of schedule (b) Retrieved old serviceable cable cover/ bricks will be laid in trenches for cable protection. If extra PCC cover / bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Exacavation and earth work will be measured and paid for separately under respective items of schedule.
M & L for making arrangement to fix reversible gear motor of cap. 01 HP working at AC 415 volts 50 Hz suitable for opening and closing of existing suction/delivery sluice gear valve of any make and size with and including connecting cable of suitable size and DOL stater with enclouser and all connecting/ fixing arrangements etc complete all as specified and directed by Engineer-in-Charge. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
S&F in replacement of exaust fan copper wounded motor of size 300 mm sweep, heavy duty working at AC 240 volt, 50 Hz with 1450 rpm complete with louver, including nut-bolts, washer and twin core cable upto 5 RM complete all as specified and directed by enginner-in-charge.(Note :-Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
S&F in replacement of PVC insulated multistranded copper conductor cable single core 1100 Volts grade of following sizes. (Note :- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV copper conductor in weight (KG) shall be taken into account and attach with RAR/F Bill)
M & L for Chemical earthing with copper earth plate 90x60cmx5mm & copper earth strip 32x6mm
M&L for removing weeds and wild grass inside the installations using chemical spray and trimming trees and unwanted plants using petrol operated Tree/Grass cutting tools and dressing of the surface by scrapping high patches and filling low patches with the scrapping soil to give an even and neat look to the site and disposing off all the unwanted grass, bushes and debris complete all as specified and directed by the Engineer-in-Charge. (Note:- Photographs of location date wise where weeds and wild grass of istallations required to be removed before execution and after completion of work will enclosed with RAR for payment purpose. If photographs not found attached with RAR, the same payment will not be allowed).
M & L in replacement Tank Cover/Valve Chamber Cover made out of mild steel plain sheet of any thickness as in cover for existing valve chamber along with provision of angle iron frame cut to length, bent to shape, welding and fabricate to requiredd shape/ size incl necessary fixing materials like hinges, nut/ bolts etc with two coat of synthetic enamel paint over a coat of red oxide primar and incl lifting handle and taking out the old unsv valve chamber cover complete all as specified and directed. (Note :- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in scrap iron weight (KG) shall be taken into account and attach with RAR/F Bill)
M&L for painting of existing Steel/RCC surface with two coat of Black/Blue colour synthetic enamelled paint including preparation of surfaces.
M&L for writing letter or figures (Block, Roman, Italic of Indian) not exc 30cm high, letter shall be painted with thick synthetic enamel paint so that they stand out boldly and solidly without showing signs or brush mark.
Material and labour Painting with two coat supper enamelled paint with of Pump set including electric driven motor, coupling, base frame, sluice valve, NRV etc of capacity up to 200 HP complete with all as specified and as directed by Engineer-in-charge.
M & L for painting of Sluice Vlave, NRV, upto 450 mm bore with two coat of supper enamelled paint including preperation of old surface complete all as specified and as directed by Engineer-in-charge.
S & F in replacement of air vent pipe of size 150 mm bore UPVC pipe 10 kgs/cum pressure heavy duty of length 0.30 mtr long and 2 nos of UPVC bend of semi under ground reservoir any capacity including necessay PCC complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement of domestic type water flow meter class 'B' conforming to IS :779/1994 all as specified and directed
Same as above but 100 mm bore dia pipe.
Same as above but 250 mm bore dia pipe.
Same as above but 400 mm bore dia pipe.
Supply and fixing in replacement of water meter waltman type of size 600 mm bore including diconnecting of existing unsv wate meter and making connection with flanged ends, with rubber gasket sheet and nut and bolts all T & P (JCB/HYdra required complete all as specified and as directed at site by Engr in charge
M&L for interconnecting of existeing rain water drain PVC pipe of size 50mm to 80mm including connecting fittings like elbow, tee , bend and including necessory road cutting /PCC cutting all as specified and directed
M&L for manual horizental boring of road /path /hardstanding for crossing of pipe up to 100 mm dia without damaging of exting road/path /hard standing
Supplying and Fix UPVC pipe of size 50 mm (SCH-80) with and including all fittings(union, elbow, tee, socket) all as specified and directed
Supplying and Fix UPVC pipe of size 75 mm (SCH-80) with and including all fittings(union ,elbow, tee, socket) all as specified and dierected
Supplying and Fix CPVC pipe 20 MM outer dia SDR 11 and plain CPVC SDR 11 with and including all fittings(union ,elbow, tee, socket) complete all as specified and as directed
Supplying and Fix CPVC pipe 25 MM outer dia SDR 11 and plain CPVC SDR 11 with and including all fittings(union ,elbow, tee, socket)fittings complete all as specified and as directed
Supply and fixing of 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability of following sizes for hot & cold water supply all PP-R plain & brass threaded polypropylene random including connecting all plain & brass fittings(elbow, union, tee, reducer, socket, plug, hose clip etc) all as specified and as directed:-
20mm dia
25 mm dia
32mm dia
40 mm dia
50 mm dia
S & F in replacement PPR Ball valve for pipe 20 mm dia (brass insert) complete all as specified and directed.
S & F in replacement PPR Ball valve for pipe 25 mm dia (brass insert) complete all as specified and directed.
M & L for making connection of PP-R distribution branch with PP-R main of following sizes by providing and fixing tee including cutting and making fusion joint all as specified and directed
16 to 40 MM dia
50 to 75 MM dia
An amount of Rs 1,67,942.00 shall be deducted from BOQ on account of schedule of credit
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.46 MB
tender.pdf
Tender Documents • 0.79 MB
BOQ_842579.xls
BOQ • 0.48 MB
Download all tender documents and submit your bid