Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC H NO 19 6 243 1 NGO S COLONY SHIV NAGAR NORTH BIDAR 585401 | BIDAR | KARNATAKA | 585401 | ₹1.1 Cr | L1 | Accepted-AOC LOWEST QUOTED BIDDER |
| 2 | L2₹1.2 Cr+₹2.9 L (2.55%)Rejected-Finance | ₹1.2 Cr+₹2.9 L (2.55%) | L2 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER |
| 3 | L3₹1.2 Cr+₹5.6 L (4.94%)Rejected-Finance | ₹1.2 Cr+₹5.6 L (4.94%) | L3 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER |
| 4 | L4₹1.2 Cr+₹9.0 L (7.92%)Rejected-Finance H NO 1 7 1 79 1 ROAD NO 7 REDDY ENCLAVE TEMPLE ALWAL SECUNDERABAD 500 010 | HYDERABAD | TELANGANA | 500010 | ₹1.2 Cr+₹9.0 L (7.92%) | L4 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER |
| 5 | L5₹1.2 Cr+₹10.5 L (9.26%)Rejected-Finance | ₹1.2 Cr+₹10.5 L (9.26%) | L5 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER |
Tender Value
₹1.2 Cr
EMD Value
₹1.9 L
Closing Date
17 Dec 2019, 6:00 pmClosed
CWE (AF) SECUNDERABAD
CWE (AF) SECUNDERABAD, BOWENPALLY-POST, SECUNDERABAD-500011
ADDITION OR ALTERATION TO DSC MESS AND BILLETS AT AFA HYDERABAD
2019_MES_274291_2
86602/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AFA) HYDERABAD
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
GE (AFA) HYDERABAD
₹1.9 L
Yes
10 Jan 2020
20 Nov 2019
18 Dec 2019
20 Nov 2019
17 Dec 2019
4 Dec 2019
20 Nov 2019 - 27 Nov 2019
Amount
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stone-work and precast concrete articles complete.
Demolition of cement concrete(unreinforced) in ground floors and pavings n.exc 15 cm thickness (below or above ground level) etc complete.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded and pointed in any mortar.
Dismantling of old HP tiles/rough sahabad stone tiles of any description or thickness in roof slabs, floors or vertical surface laid, bedded and pointed in any mortar including bedding screed and backing in vertical surfaces and removal of unserviceable debris to a distance not exceeding 100m complete all as specified and as directed.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
Demolition of reinforced cement concrete in ground floors and pavings n.exc 15 cm thickness (below or above ground level) etc complete.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc.
M&L for Brushing neat cement slurry with 3.0kg of cement per sq. meter complete all as specified and as directed.
Taking down cement plaster of any description any thickness incl racking out joints hacking for key scrubbing down with water etc all as specified & directed.
Taking down chowkats or frames with shutters exc 1.5 sqm but n.exc 4 sqm each (without taking off shutters from the frame) complete all as specified and as directed.
Taking down chowkats or frames with shutters n exc 1.5 sqm (without taking off shutters from the frame) complete all as directed.
Taking down Shutters of any description exc 1 sqm but n exc 2 Sqm each and refixing in the same opening complete
Taking down Shutters of any description exc 1 sqm but n exc 2 Sqm each complete
M&L for 2nd class hard wood plain, solid, straight, chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints,supplied and fixed complete all as specified and as directed.
S&F factory made 35 mm thick flush shutters, solid core construction with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed.
S&F 35mm thick 2nd class hard wood Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and as directed.
S&F 35 mm thick 2nd class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. cla-use 8.20 (a); supplied and fitted to chowkats complete all as specified and as directed.
S&F for Factory made solid panel pvc door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel heaving a PVC sheet strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing complete.
S&F for Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specification & drawing complete
M & L for Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or FE 310-0 complete all as specified and as directed.
S & F 100 mm size butt hinges, medium weight, cold rolled mild steel etc., complete all as specified and as directed.
S&F of Aluminium anodised,barrel tower bolts of extruded section of size 200mm long etc complete all as specified and as directed.
S&F of Aluminium handles, cast type, anodized of size 150 mm long etc complete all as specified and as directed.
S&F Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type)of size 300mm and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed etc complete all as specified and as directed.
Dismantling of structural steel work including windows, ventilators, door, gates etc but excluding framed truss etc (without taking off shutters from the frames) of any description and any size complete all as directed.
Cutting openings through walls for door, window and other openings or enlarging existing openings, etc., including providing, fixing and removing, shoring, cleaning and stacking stone and removing surplus stone and rubbish off the premises etc complete.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 etc complete all as specified and as directed.
M&L for providing cement concrete PCC 1:2:4 type B-1 mix using 20 mm graded stone aggregate as in bed blocks for hold fasts etc complete all as specified and as directed.
S&F for Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed.
S&F in repairs for Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed.
Hacking out old unserviceable glass / broken glass panes of any description, from old wooden or metal frames, or stone, concrete or brick surrounds any thickness or size complete all as specified and as directed.
S&F 5mm thick Sheet glass, ordinary quality and glazing with oil putty in square in exc 0.5 sqm in each pane complete all as specified and as directed.
S&F 4mm thick figured glass, pin head type and glazing with oil putty in squares n .exc 0.5 sq. m in each pane complete all as specified and as directed.
M & L for preparation of old steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint complete all as specified and as directed.
M & L for preparation of new wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
M & L for screed bed or bedding layer of 15mm thick in cement mortar 1:6 for laying floor finishes complete all as directed.
M & L for 20 mm thick screed bed or bedding layer in cement mortar 1:6 for laying sadarali stone slab, granite and cuddapa stone floor finishes complete all as directed.
M & L rendering 10mm thick on fair faces of brick work or concrete surfaces of cement plaster 1:4 and finished even and rough as backing coat for fixing skirting or dado complete all as specified and as directed.
M&L for 20mm thick Granite (of any type) work (table rubbed and polished) full length in steps, jambs, pillars, windowcills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed. Note:- Screed bed will be measured & paid separately.
M&L for coloured Vitrified Ceramic tiles 10 mm thick (Square/rectangular) polished area of each tile not exceeding 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed. Note:- Screed bed will be measured & paid separately.
All as per Item No. 41 above but as in skirting/dado
M & L for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed. Note:- Screed bed will be measured & paid separately.
M&L for laying of Glazed ceramic tiles in vertical surface 450x 300x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match etc complete all as specified and as directed. Note:- Backing coat will be measured & paid separately.
M&L for Machine cut mirror polished Sadarali stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed. Note:- Screed bed will be measured & paid separately.
All as per item No. 45 above but in skirting /dado
M&L for Machine cut mirror polished Sadarali stone slab 20-25mm thick as in riser or steps in full length, skirting, dado and pillar laid over cement screed bed or backing coat complete all as specified and as directed. Note:- Screed bed / backing coat will be measured & paid separately.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform and other similar situations complete all as specified and as directed.
M&L for Machine cut cudappah stone slab minimum 20mm thick over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed. Note:- Screed bed will be measured & paid separately.
Taking down existing tar felt, water proofing membrane, water proofing plaster, cement mortar screed, roughening surfaces to receive plaster/screed etc. including cleaning up the surface with water and wire brush and removal of unserviceable debris to a distance n exc 100m complete all as specified and directed.
M&L for plain Cement concrete type B-1, 1:2:4 (20mm graded aggregate) average 50mm thick as padding over roof slab including maintain proper slope and making good the depressed/undulation portions on roof complete all as specified and directed by Engr-in-Charge.
M&L for Rendering 10mm thick in CM 1:3 mixed with water proofing compound/liquid as per manufactures instructions on concrete/brick surfaces finished even and fair without using extra cement complete all as specified. ( Note :- WPC will be measured and paid separately).
M&L for Cleaning the roof surfaces and applying bitumen primer @0.20 Kg per Sqm providing and laying 4mm thick APP modified water proofing membrane weight not less than 4 Kg per Sqm reinforced with non woven polyester mat weight not less 160 gm per Sqm having softening point not less than 140 Degree centigrade, longitudinal tensile strength not less than 800N per 5 cm tearing strength of 180N (by torch application method) with minimum of 10 cm side laps and 15 cm end laps by application of torch. Applying a coat of blown grade hot bitumen 90/15 over the membrane @ 1.20 kg/sqm all as specified and as per manufacturer instructions and as directed by Engineer-in-Charge.
Preparing the existing sunken floor surface thoroughly to remove all loose particles, dirt/dust particles and applying bitumen primer at 0.20 Kg/Sqm followed by APP membrane minimum 3mm thick at 3Kg/sqm and followed by blown bitumen 90/15 grade at 1.20Kg/Sqm complete all as specified and as directed.
M^&L for Cement concrete tiles 25cm x 25xm x20mm thick, machine pressed; set, jointed and poin ted in net cement slurry in floors, with grey cement and no pigment, and cut and polished complete all as specified and as directed.
Supply only intergral water proofing compound/ liquid to mixed with cement mortar etc complete all as directed.
S & F in repairs Vitreous chinaware under counter basin of size 590X420X200 mm oval shape white comprising basin, including supply and fixing of waste pipe and the following components viz. waste fittings and connecting upto supply pipes, wastes or traps, screws, plugs, cement mortar and other subsidiary materials required for fixing complete all as specified and as directed. Make : Jaquar Cat Part NO. CNS-WHT-705 or equivalent as approved by GE.
S&F in repairs of Vitreous china squatting pan, Orissa pattern of size 580 x 440mm, white with integral foot rest including connection to trap and to flushing pipe, anti-syphonage pipe, and with P or S trap, including making good to floor complete all as specified.
S&F in repairs 10litres PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets High or low level flushing cistern and connections to pipes and fixing complete all as specified.
S&F in repairs vitreous china urinals, half stall bowl type (back or corner wall type),complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; flush pipe, grating and Union for discharge pipe. (Excluding flushing cistern, flush pipe and waste pipe) including connection with waste pipe complete all as specified.
S&F in repairs Vitreous china urinal partition white of size 310x700 mm slabs terminating about 40cm above floor line complete all as specified and as directed.
S&F in repairs chromium plated urinal spreader of any colour for fixing with 15mm dia pipe (Minimum weight 60gms) complete all as specified and as directed.
S & F in repairs sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm incl taking down extg sinks complete all as specified and as directed.
S & F in reapirs pillar tap, suitable for counter type cell, fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered "Hot "or "Cold" with long screwed shanks and fly nuts, screwed for iron pipe of bore of pipe 15mm fixed complete all as specified and as directed.
S&F in repairs of Brass chromium plated shower rose LONG ARM with or without swivel joint any size including fixing to steel pipe or union, of size 125mm complete all as specified and as directed.
S&F in repairs Bib taps, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed to 15mm bore pipe complete all as specified and as directed.
S&F in repairs of stop valves 15mm dia cast copper alloy fancy type CP screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions, of 15mm bore etc complete all as specified and as directed.
S&F in repairs concealed stop cock/angle cock of 15mm dia chromium plated with long shank and cup etc complete all as specified.
S&F in repairs PVC connections 15mm size with brass union of length 450mm complete all as specified.
S&F in repairs chromium plated gratings 100mm dia with provision of with or without hole, fixed with suitable solvent cement etc., complete all as specified.
S&F in repairs of Rotational moulded PVC water storage tanks of 1000 ltrs capacity (cylindrical vertical with closed top) , two layered, hoisted and fixed in position all as specified in SSR Pt-I complete all as specified.
S&F in repairs of Ball valve 25mm dia high pressure PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum wt. 455gms etc complete all as specified.
S&F in repairs of Gun metal globe or gate valves of 25mm dia with iron wheel head screwed both ends for iron pipe etc. complete all as specified.
Cutting holes of superficial area n.exc 150 sq.cm into or through brick//PCC block masonry walls, built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required etc complete all as specified and as directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth for brick walls complete all as specified.
Taking up or down steel tubing 15mm dia and connections, including cleaning for refixing or removal to store complete all as specified.
Taking up or down steel tubing 20mm dia and connections, including cleaning for refixing or removal to store complete all as specified.
Taking up or down steel tubing 25mm dia and connections, including cleaning for refixing or removal to store complete all as specified.
S&F 20mm outer dia 3 layer PP-R Polypropylene random copolymer pipes SDR 7.4 (PN-16) UV stablised and antimicrobial fusion welded having thermal stability for hot and cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to wall, ceiling or in floors etc., complete all as specified.
S&F 25mm outer dia 3 layer PP-R Polypropylene random copolymer pipes SDR 7.4 (PN-16) UV stablised and antimicrobial fusion welded having thermal stability for hot and cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to wall, ceiling or in floors etc. complete all as specified.
S&F 32mm outer dia 3 layer PP-R Polypropylene random copolymer pipes SDR 7.4 (PN-16) UV stablised and antimicrobial fusion welded having thermal stability for hot and cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to wall, ceiling or in floors etc.complete all as specified.
Making connection of PP-R distribution branch with PP-R main of sizes 16 to 40mm bore pipe by providing and fixing tee including cutting and making fusion joint etc.
Dismantling of cast iron /PVC pipes of any description and in any position complete all as directed.
S&F 100mm cast iron sanitary connection socket to fit WC out let etc complete all as specified.
S&F 100mm bore sand Cast iron soil, waste and vent pipes, in any length with or without ears with cement joints, laid in trenches or in floors complete all as specified and as directed.
S&F 75mm bore sand Cast iron soil, waste and vent pipes, in any length with or without ears with cement joints, laid in trenches or in floors complete all as specified and as directed.
S&F of Cast iron floor trap of 75mm size with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and as directed.
S&F of Cast iron bends 100mm bore diminishing pieces or tapers complete all as specified and as directed.
S&F of Cast iron oval access door bends 75mm bore complete all as specified and as directed.
S&F of 160 mm dia PVC(SWR) pipes single socketed, in any length with rubber ring joints, fixed on walls for rain water pipe etc complete all as specified and as directed.
S&F of 110 mm dia PVC(SWR) pipes single socketed, in any length with rubber ring joints, fixed on walls for rain water pipe and wc outlet pipe complete all as specified and as directed.
S&F of 75mm dia PVC(SWR) pipes double socketed, in any length with rubber ring joints, fixed on walls for rain water pipe and wc outlet pipe complete all as specified and as directed.
S&F in repairs 160mm dia PVC (SWR) plain bend complete all as specified.
S&F in repairs 110mm dia PVC (SWR) plain bend complete all as specified.
S&F in repairs 110 mm PVC (SWR) branch piece, single (single Y) equal or unequal complete all as specified.
S&F in repairs 110 mm PVC (SWR) branch piece, single (single Y) equal or unequal with provision of access door etc complete all as specified.
S&F in repairs 75mm PVC (SWR) plain bend complete all as specified.
S&F in repairs 75mm dia PVC (SWR) plain bend with provision of access door etc complete all as specified.
S&F in repairs 110mm PVC (SWR) Vent cowl complete all as specified.
S&F in repairs 75mm PVC (SWR) Vent cowl complete all as specified.
S&F MS work as in clamps, supports or stays for rainwater pipe, ventilating pipes including bolts if required and pintle hinges; hand made sliding bolts; clamps; hold fasts; wall ties; plain angle cleats for securing and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified.
M&L for gunniting work to RCC structure as in column, soffits of slabs, chajja, fascia, lintel beam, roof beam, plinth beam, etc by removing loose concrete cover etc. cleaning the surface with wire brush and applying epoxy paint to rusted reinforcement and supply and fix welded wire mesh fabric or wire net less than 95x95x3mm th adhesive, plaster grade for concrete admixture 1 part of cement and 3.5 part sand and avreage thickness 40mm and making the surface even including 15mm thick plaster in CM 1:4 finishing the surfaces even and smooth, without using extra cement plumb and making surface true to geometry in line and including necessary form work to carried at upto double story building complete all as specified and directed. Note : Whereever reinforcement required will be measure and paid seperatly.
M&L for Rendering 15mm thick in cement mortar 1: 6 on faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M&L for Rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces external wall surfaces with WPC of finished even and smooth (without using extra cement) all as specified and as directed.Note : WPC will be measured and paid separately.
M&L for rendering 10mm thick in CM 1:4 on concrete surfaces as in ceiling finished even and smooth (without using extra cement) all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats or oil emulsion distemper over a coat of primer etc complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement based paint over a coat of primer etc complete all as specified and as directed.
M&L for preparation of newly plastered surfaces on ceiling surfaces and applying three coats of white wash complete all as specified.
M&L for complete removal of the existing treatment on walls and applying two coats of distemper oil emulsion over 3mm thick wall care putty on plastered surfaces preparatory to distemper including preparation of surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for complete removal of the existing treatment on walls and applying two coats of exterior weather coat paint over a coat of alkali resistant priming paint including preparation of surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for complete removal of existing wall surfaces and applying three coat of white wash complete all as specified and directed.
M&L for complete removal of existing ceiling surfaces and applying three coats of white wash complete all as specified and directed.
M & L for preparing old painted wood and wood based surfaces of any description, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint all as specified and directed by Engineer-in-Charge.
M & L for preparing old painted steel and iron surfaces of any description, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint all as specified and directed by Engineer-in-Charge.
M & L for preparing old painted steel surfaces of any description, not otherwise described not exceeding 10cm width or girth and applying one coat of synthetic enamel paint all as specified and directed by Engineer-in-Charge.
Excavating in post holes (or similar holes) each n exc 0.5 cu. M, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface in hard/dense soil complete
M&L for Plain cement concrete 1:4:8 in foundation filling and mass concrete type D2 using 40 mm graded stone aggregate complete all as specified and as directed.
S&F Steel work in tubular trusses including post, special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 complete all as specified and as directed.
Removing excavated material exceeding 1.5KM but not exceeding 5 KM and depositing where directed at a level n exc 1.5 m above the starting point all as specified and directed.
S&F 2mm thickness Fibre glass reinforced translucent corrugated sheeting with two corrugation side lap fixe with coach screw and washer in roof, wall etc. complete all as specified and as directed.
M&L for MS hand rail straight portion, drilled and counter sunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting etc. and similar works conforming to Fe 410-0 or Fe 310-0 complete all as specified and as directed.
S&F Stainless steel railing of height 1m with 50mm dia SS pipe as Newel post and 40mm dia SS pipe for verticals and 25mm dia SS pipe for horizontals all as shown on drawing and as specified and directed by Engr-in-charge.
Taking down carefully unserviceable point wiring of light points, fan, socket out let on TW battens / PVC pipes / sockets, switches, shades, ceiling roses, regulators, light fittings etc and removing the materials from site and making good the disturbed portion of walls/floors ceiling etc complete all as specified and as directed.
Taking down Ceiling Fan of any Sweep and Make by disconnecting Electric Connection, dismantling Blades, Down Rod and removing Ceiling Fan handed over to MES STORE YARD OF AGE E/M (AFA) Hyderabad for re-use complete all as specified and as directed.
M&L for hanging only ceiling fan / wall mounted fans as dismantled under item No. 126 above and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed by Engineer-in-charge.
Taking down carefully un serviceable MCB DB SPN / TPN with MCB,s etc and removing the materials from site and making good the disturb portion of walls/floors ceiling etc complete all as specified and as directed.
M&L for Point wiring complete with 1.5 sqmm single core FRLS grade 1100 V PVC insulated unsheathed wire with multi stranded copper conductor drawn through in and including PVC casing & capping and accessories ISI marked & PVC boxes fixed surface on wall / ceiling/ roof etc and including provision of 1.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FRLS ISI marked as earth continuity conductor etc, complete all as specified for the following :- One light / fan point controlled by one, one way switch
All as per Item No. 129 above but One 5Amps Socket point on same board
All as per Item No. 129 above but One 5Amps Socket point controlled by one, one way switch
M&L for Point wiring complete with 2.5 sqmm single core FRLS grade 1100 V PVC insulated unsheathed wire with multi stranded copper conductor drawn through in and including PVC casing & capping and accessories ISI marked & PVC boxes fixed surface on wall / ceiling/ roof etc and including provision of 2.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FRLS ISI marked as earth continuity conductor etc, for 15Amps Power Sockets etc along with 3 mm thick top laminated bakelite sheet complete all as specified and directed by Engineer-in-Charge.
S&F switch piano flush button single pole one way 5 Amp complete all as specified.
S&F of Switch socket combination polycarbonate white 5 in 1, 5 pin, 5 and 15 Amp flush type universal complete all as specified.
S&F of Switch socket combination polycarbonate white 2 in 1, 3 pin, 5Amp flush type complete all as specified and as directed.
S&F of Socket Outlet polycarbonate white 2 in 1, 3 pin, 5Amp flush type complete all as specified and as directed.
S&F of stepped type polycarbonate white electronic fan regulator flush type 2 module all as specified and as directed.
S&F of ceiling rose, three terminal, PVC/polycarbonate, insulated body, ISI marked complete all as specified and as directed.
Supply and fix socket of 32A, 3 pole, Neutral and earth terminal indoor type wall socket, with DIN rail, IP 44 including all fixing accessories etc and with one MCB TPN 32 Amp, 240V, 50 Hz, AC and including 01 No 32 Amps, 3P+N+ E Plug Sockets complete enclosed in thermo plastic enclosure all as specified and as all as directed.
S&F of single pole and neutral enclosure with a two pin and earth plug and socket complete with one number single pole MCB 20 Amps , 240 Volts complete all as specified and as directed.
S&F LED 20 to 24W decorative Wall mounted fitting, including bulb with all accessories internally pre-wired, connecting up with twin core twisted flexible copper conductor cable white colour complete all as specified and directed by Engineer-in-Charge.Make : Havells Cat Part No. 20W 840SPCWH or equivalent in Wipro/Philips/CG as approved by GE.
Supply and fix flexible LED strip, with wide viewing angle for good light distribution & IP 40 protection, linkable and easy to install, complete with separate replaceable electronic driver with all accessories internally pre-wired, connecting up with twin core twisted flexible copper conductor cable white colour complete all as specified and directed by Engineer-in-Charge. Make : Philips/CG/Havells /Wipro
Supply and Fix 1X 5 to 8W decorative recess mounting spot light in all accessories internally pre-wired, connecting up with twin core twisted flexible copper conductor cable white colour complete all as specified and directed by Engineer-in-Charge. Make : CG Cat Part No. LGSTR-07-W or equivalent in Wipro/Philips/Havells as approved by GE.
S&F surface mounted type LED tube light fitting 1 x 18 to 20watts LED batten type including LED tubes complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified. Make :CG Cat Part No. LCCLB20-CDL or equivalent in Wipro/Philips/Havells as approved by GE.
S&F surface mounted type LED tube light fitting 1 x 8 to 10watts LED batten type including LED tubes complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified. Make :CG Cat Part No. LCTL-9-CDL or equivalent in Wipro/Philips/Havells as approved by GE.
S&F recess mounting LED light fitting of size 600x600mm 36W to 40W LED complete with inbuilt driver, 230 V with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-charge. Make :CG Cat Part No. LCPL-36-CDL or equivalent in Wipro/Philips/Havells as approved by GE.
Supply and Fix 1X6 to 10W LED picture light including driver with all accessories internally pre-wired, connecting up with twin core twisted flexible copper conductor cable white colour complete all as specified and directed by Engineer-in-Charge.Make :CG /Havells/Wipro/Philips.
Supply & fix fan ceiling complete with out regulator and including connected accessories like down rod, canopy, clamps etc 230 V, 1200 mm sweep BEE 5 star rated and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing exhaust fan with louvers 450 mm sweep, 1440 RPM, Heavy duty single phase 240 Volts, AC 50 Hz and connecting up including louvers and making good with matching colour with the surroundings provision of cable 3 core of size 0.5 Sqmm (16/0.2 mm) from ceiling rose to fan , including making necessary opening on stone /brick masonry wall and all as specified and as directed. Note : For Cook House & Chapathi Making room
Supply & Fixing exhaust fan with louvers 300 mm sweep, 1440 RPM, Heavy duty single phase 240 Volts, AC 50 Hz and connecting up including louvers and making good with matching colour with the surroundings provision of cable 3 core of size 0.5 Sqmm (16/0.2 mm) from ceiling rose to fan , including making necessary opening on stone /brick masonry wall and all as specified and as directed. Note : For Toilets
Supply and fix desert cooler electric driven (single phase), having nominal air flow capacity of 4000 CuM per hour (or nearest size) with steel body including supporting mild steel stand made of 40x406mm angle iron with two coats of painting over primer complete all as specified and directed by Engineer-in-Charge.
Supply & Fix sheet steel enclosure with double door, vertical type MCB DB for MCB's fitted with busbars, earth bar and neutral links with provision of MCB TPN as incomer and TP/SP MCB's as outgoing 415 V, 4 ways IP-43-Ik 09 protection. Note : MCCB / MCB's will be measured and paid separately under relevant item.
Supply and fixing MCCB 4 pole, 63Amps, 415 volts, Breaking capacity 16KA complete all as specified and directed by Engineer-in-Charge.
Supply and fixing MCB single pole 240 volts, 6-32 amps, 10KA complete all as specified and directed by Engineer-in-Charge.
M&L for Sub Main wiring PVC insulated cable 4runs of single core 10sq mm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through and including rigid non-metallic PVC conduit / casing & capping of suitable size with ISI marked incl all specials like joint elbow, Tee, junction, bend etc and provision of two runs of PVC insulated copper conductor single core of same size for earth continuity complete all as specified and directed. Note (I): Necessary PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge for point wiring work with PVC dummy plates shall deemed to be included in the quoted rate. (II)Six runs of cable 10 sqmm and one run of conduit with necessary accessories will be measured as one unit length. (III) The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.
M&L for Sub Main wiring PVC insulated cable 2runs of single core 6sq mm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through and including rigid non-metallic PVC conduit / casing & capping of size not less than 25mm dia (ISI marked) incl all specials like joint elbow, Tee, junction , bend etc and provision of one runs of PVC insulated copper conductor single core of same size for earth continuity complete all as specified and directed. Note (I): Necessary PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge for point wiring work with PVC dummy plates shall deemed to be included in the quoted rate. (II) Three runs of cable 6 sqmm and one run of conduit with necessary accessories will be measured as one unit length. (III) The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.
M&L for earthing complete with Galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised earth wire 4mm dia connected by means of bolts, nuts, check nuts and washer of galvanised iron or steel, provision of 15 mm dia GI pipe medium grade for protection of GI earth wire and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type C1 chamber, MS funnel, wire gauge, 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I Note: (i) Cost of GI earth wire and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation,returninng & filling, PCC chamber pit,RCC cover & test point (iii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit
Surface excavation in soft/loose soils n exc 30 cm thick and avg 15cm thick complete all as specified and as directed
Rolling and consolidating formation surfaces in cutting with Exc 8 tone n exc 12 tonne capacity power roller complete all as specified and as directed.
Soling (or sub base) with broken boulders or quarried stone, interstices filled, surface formed and rolled Spread thickness 200mm and consolidated to required gradient and camber complete all as specified and as directed.
M&L for Wet Mix macadam (WMM)150mm thick compacted thickness in two layers of 75 mm thick each layer with coarse granite stone aggregate of specified grade spread using mechanical paver as specified, rolled and compacted using 8 to 12 tonne capacity vibratory power roller to required camber and gradient complete all as specified. Note: Quoted rate shall be for 150 mm thick consolidated thickness in two layers (each of 75 mm thick compacted thickness).
M&L for Paving bitumen applying evenly a priming/tack coat with bituminous primer at 6 Kgs/10Sqm using paving bitumen VG-30 over WBM surfaces allow it to penetrate at least 5 to 10 mm from top surface of WMM all as specified and as directed.
M & L for Bituminous premix semi dense asphaltic concrete (SDAC) 40mm (consolidated thickness) in single layer using paving bitumen of grade VG-30 with 5.5% minimum binder content mixed by weight of total mix as wearing course, using hot mix plant and laid by using mechanical sensor paver, rolled and compacted to required camber and gradient complete all as specified.
Preparing black top surfaces by brushing with wire brushes for removing caked mud etc, sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc, applying evenly a priming/tack coat with viscosity grade paving bitumen (VG-30) at 5 Kg per 10 Sqm and applying bituminous premix semi dense asphaltic concrete (SADC), 30 mm consolidated thickness with 5.5% binder content by weight of total mix using paving bitumen and penetration, rolled with 8 to 10 tonne capacity power roller and compacted to required camber and gradient complete all as specified and directed by Engineer-in-Charge . Note :- No price adjustment shall be applicable if excess quantity of binder content is/used/approved in execution of work under this item on plus side. However price adjustment shall be made for less quantity of binder content.
Removal of excavated soil material to a distance exc 1.5 Km but not exc 5.0 Km and depositing as directed at a level not exceeding 1.50 above the starting point.
M & L for 100 mm thick hardcore of gauge n exc. 63mm, deposited, spread, and levelled in layers n exc 15cm thick well watered and rammed to a true surface complete all as specified and as directed.
M&L for 75mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in Sub base complete all as specified and as directed.
M&L for 40 mm thick PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in paths laid In pannels complete all as specified and as directed.
Spike roiling to surfaces or making impressions of expanded metal, whilst the concrete is green complete all as specified and as directed.
M&L for screed bed or bedding layer of cement mortar 20mm thick for laying floor finishes in CM (1:6) etc complete all as specified and as directed.
M & L for laying cement chequered self glossy tile of size 300X 300X20-25mm thick jointed and pointed in with cement to matching colour etc , with greycement no pigments etc complete all as specified and as directed.
Supply and lay LT UG cable, XLPE insulated armoured, heavy duty aluminium conductor multistranded, 1100volts grade, of 10Sqmm x 2core cross sectional area laid in trenches / fixing on walls / poles or passing through GI pipe including connecting up with suitable lugs, nuts and bolts wherever required and testing complete all as specified.
Supply and fixing cable route indicator, consisting of 200mm dia 6mm thick cast iron to be painted with “BLUE” colour with inscription casting as LT Cable and fixed with and including hot dipped GI angle of size 40mm x 40mm x 6mm, 0.60m long, GI bolts, nuts embedded in ground in route of cable with and including PCC 1:3:6 type C2 of size 200mm x 200mm x 300mm complete all as specified and as directed.
Supply and fix cable junction box 200 X160 X 98 mm in size made out of thermoplastic sheet having IP 65 protection for out door installation fixed with 4 way bakelite cable terminals with one MCB SP 6 Amps to be fixed inside the box including 03 Nos polymide gland with checknut (M-32 - 3 Nos) fixed on pole with flat iron clamps of size 25 x 3 mm, nuts, bolts, washers etc., including two coats of synthetic enamel paint over a coat of redoxide zinc chrome primer all as directed by Engineer-in-charge .
M&L for Sub Main wiring PVC insulated cable 2runs of single core 1.5sq mm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through and including rigid non-metallic PVC conduit of suitable size with ISI marked incl all specials like joint elbow, Tee, junction , bend etc and provision of one runs of PVC insulated copper conductor single core of same size for earth continuity complete all as specified and directed. Note (I): Three runs of cable 1.5 sqmm and one run of conduit with necessary accessories will be measured as one unit length. (II) The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.
S&F LED Decorative Post top lantern type fitting 1x36 to40W IP 65 protection, resistant to impact and corrosion, glare free and better uniformity and accessories including of GI pipe light grade of suitable size up to required level and connecting accessories complete all as directed. Make : CG cat part No. LPTO-40-CDL/M OR equivalent in Wipro/Philips/Havells as approved by GE.
M&L for earthing complete with Galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised earth strip 25x4mm connected by means of bolts, nuts, check nuts and washer of galvanised iron or steel, provision of 40mm dia GI pipe medium grade for protection of GI earth wire and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type C1 chamber, MS funnel, wire gauge, 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I Note: (i) Cost of GI earth wire and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation,returninng & filling, PCC chamber pit,RCC cover & test point (iii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit
Excavation in trenches in soft/loose soil n.exc 1.5 m wide and n. exc 1.5 m depth and getting out complete all as specified and as directed.
M & L for cutting of road/ hard standing up to 0.3m in depth and 0.45m wide for laying of cable protection pipe including refilling, watering, well ramming and finishing with PCC 1:2:4 and matching with surroundings, removing the broken PCC / road materials and clearing the site complete all as directed by Engineer- in-charge.
Returning, filling in including spreading, leveling, and well ramming in layers not exc 25cm in soil complete all as specified and directed.
Removing surplus excavated material (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed
Supply and filling River dry sand cushioning to UG cables (8 cm deep before laying of cable and 15 cm deep over the cable) in trenches including punned thickness up to 18 cm and consolidation, complete all as directed. Note :- Punned thickness only will be considered for payment.
M&L brick sub class B designation 75 locally available best quality laid in trenches above sand cushioning for cable protection complete all as specified and directed.
M&L for light grade galvanized pipe ISI marked with all fitting, laid in trenches, under road or fixing on wall/pole/ crossing nallah etc of bore 80 mm complete all as specified and as directed .
Excavation in trenches n.exc. 1.5 m wide and n.exc. 1.5 m deep and getting out in soft/loose soil complete all as specified and as directed.
M&L for pre-cast cement concrete block masonry of Type C1 1:3:6 (using 20mm graded stone aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar 1:4 etc complete all as specified and as directed.
Forming fair finished drain using extra cement including forms, moulds, mitred/stopped ends etc., complete all as specified and as directed.
S & F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally hooping for columns, hooking ends and binding with mild steel wire annealed not less than 0.9mm dia complete all as specified and as directed.
M&L for RCC 1:2:4 Type B-1 (using 20 mm graded stone aggregate) in cover slabs including necessary form work complete all as specified and as directed.
Dismantling post or struts (wood, steel, RCC)embedded in concrete any section including taking out embedded portion from natural ground and making good disturbed ground
Dismantling wrought iron or mild steel work of any description not otherwise provided for
Dismantling fencing wire mesh, any type
M&L for excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, drains etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil.
M & L for Brick work with sub class 'B' bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:4 complete all as specified and as directed.
M&L for providing Cement concrete 1:2:4, type B-1 mix using 20 mm graded aggregate as in coping, benching/channels complete all as specified and as directed.
M&L rendering 15 mm thick in cement plaster 1:4 on fair faces of brickwork or concrete surfaces finished even and smooth without using extra cement
M & L for Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces of concrete complete all as specified and as directed.
Formwork to sides of concrete pillars, posts, struts, piers, columns and stanchions in foundations and similar work for rough finished surfaces of concrete complete all as specified and as directed.
M & L for RCC(1:2:4) Nominal Mix as in foundation, including raft, footing, foundation beam, plinth beam, bases for column etc, basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M & L for RCC(1:2:4) Nominal Mix as in columns, pillars,piers, posts and struts and mass concrete complete all as specified and as directed.
Providing, cement concrete in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates and the like including weathering, slightly rounded or chamfered an-gles and throating complete all as specified and as directed.
S & F Mild Framed work such as for portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, welding, and fixing in RCC column and beam during the casting time of column and beams post strut in fencing and , wind tie, including all necessary drilling, bolting or riveting etc., and similar work conforming to Fe 410-0 or Fe 310-0 as directed by Engr-in-Charge.
S & F Mild steel bolts exc 12mm n exc 20mm purpose made with hexagonal or square head one end and screwed the other, or screwed end to be fitted with washers and one hexagonal or square nut exc 30 cm long complete all as specified and as directed.
Surface dressing not exc 15 cm average depth cutting/uprooting filling and cleaning of shrubs, vegetation , grass bush, weeds etc incl making good the disturbed area and depositing of to a distance n. exc 50 mtr as and as directed by Engineer-in-Charge
Fixing only chain link fencing including line wires, any mesh, size type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and as directed.
Supply only galvanised chain link fencing any size or type.
M & L for preparation of new steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
M/s RL Pareek
B R C CONSTRUCTIONS
G SATISH REDDY AND CO
GUTHIKONDA BROTHERS
Dwarka Pershad Radhey Ramanlal
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .