| 1 | | SITC of 5.0 TR High Static Fan Coil Airconditioning Unit with of rated cooling capacity of 60000 BTU/hr with 2 Nos. Recip./Twin rotary type Compressor , 2 nos. IDU of rated power supply 230V-Single.ph-50Hz with centrifugal blower and corded remote control. Air-flow/per IDU 800CFM including charging of refrigerant. Make carrier / Mitshubishi Heavy Industries / Daikin / O-General | 2 | Nos | [email protected] | 120 |
| 2 | | SITC of split type fixed speed, Non-Inverter Air conditioning machine having the following major specification EER 3.5 ,Compressor Type Hyper Tropical Rotary, Rated Cooling Capacity Watts 7250, Rated Power Input Watts 2070, Air volume indoor unit m3/h 1480 6 speed fan control , Dual suction intake design, powerful cool and wide & long airflow approx-20Mtr. Air Sleep Cooling Technology, LCD remote control, Electronic metal housing box, 12 hour on and off timer, auto restart, auto double swing, etc. Refrigerant-R410A. Along with powdered coated heavy duty fancy angles with vibration pads, 3 mtrs necessary copper piping with nitrile rubber insulation, wrapping of the copper pipe is essential, complete in all respect. Min. BEE Star rating minimum- 3 star,Min.capacity 2 Tr. | 29 | Nos | [email protected] | 120 |
| 3 | | SITC of split type fixed speed, Non-Inverter Air conditioning machine having the following major specification EER 3.5 ,Compressor Type Hyper Tropical Rotary, Rated Cooling Capacity Watts 5470, Rated Power Input Watts 1560, Air volume indoor unit m3/h 1400 6 speed fan control , Dual suction intake design, powerful cool and wide & long airflow 18MTR Air Sleep Cooling Technology, LCD remote control, Electronic metal housing box, 12 hour on and off timer, auto restart, auto double swing, etc. Refrigerant-R410A.Along with powdered coated heavy duty fancy angles with vibration pads, 3 mtrs necessary copper piping with nitrile rubber insulation, wrapping of the copper pipe is essential, complete in all respect. Min. BEE Star rating 3 star,Min.capacity 1.5 Tr. | 9 | Nos | [email protected] | 120 |
| 4 | | SITC of 2.0 TR Tower type Split Air Conditioners fitted with scrolled compressor are designed to operate on single ph. 230 volts, 50 Hz. AC supply. Cooling capacity nominal BTU/HR 24000 , Min room discharge Air Flow rate 1650CMH/min. providing Refrigerant R410A/R32. The PCB board of indoor unit should be covered by metallic enclosure. Cordless remote arrangement with all modernized provision of temperature. Auto swing, | 4 | Nos | [email protected] | 120 |
| 5 | | SITC of window type fixed speed, Non-Inverter Air conditioning machine having the following major specification EER 2.98 ,Compressor Type Advanceed Hyper Tropical Rotary, Rated Cooling Capacity Watts 5370, Rated Power Input Watts 1800, Air volume m3/h 940,6 Row coil , powerful cooling and extreme airflow, LCD remote control, 12 hour on and off timer, auto restart, auto swing, etc. Refrigerant-R410A. Min. BEE Star rating 3 star,Min.capacity 1.5 Tr | 1 | Nos | [email protected] | 120 |
| 6 | | Supply and fixing 5/8 inch of hard / soft copper refrigeration pipeline with 9 mm thick Nitrile Rubber insulation, complete with fittings, elbows, bends, supporting arrangement on walls. The pipe should be wrapped with Wrapping tape through out its length. | 200 | RMT | [email protected] | 120 |
| 7 | | Supply and fixing 3/8 inch of hard / soft copper refrigeration pipeline with 9 mm thick Nitrile Rubber insulation, complete with fittings, elbows, bends, supporting arrangement on walls. The pipe should be wrapped with Wrapping tape through out its length. | 70 | RMT | [email protected] | 120 |
| 8 | | Supply and fixing 1/2 inch of hard / soft copper refrigeration pipeline with 9 mm thick Nitrile Rubber insulation, complete with fittings, elbows, bends, supporting arrangement on walls. The pipe should be wrapped with Wrapping tape through out its length. | 200 | RMT | [email protected] | 120 |
| 9 | | Supply and fixing 1/4 inch of hard / soft copper refrigeration pipeline with 9 mm thick Nitrile Rubber insulation, complete with fittings, elbows, bends, supporting arrangement on walls. The pipe should be wrapped with Wrapping tape through out its length. | 400 | RMT | [email protected] | 120 |
| 10 | | Supplying and laying of 1.1 KV grade XLPE multi core control cable of 6 Core 2.5sq mm. for connecting conrresponding IDU to corresponding ODUs as per standard code of practice and in accordance with rules of local Electric supply Authority. Make- Ploycab/Finolex/Gloster/Havells | 300 | RMT | [email protected] | 120 |