Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.9 LAccepted-AOC 01 ENTERPRISES | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹19.9 L+₹97,799.45 (5.18%)Rejected-Finance | L2 | Rejected-Finance Quoted other than lowest rate | |
| 3 | L3₹21.8 L+₹2.9 L (15.2%)Rejected-Finance 18969 A 1 SHRI GURU TEG BAHADUR NAGAR BIBIWALA ROAD STREET NO 15 BATHINDA 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L3 | Rejected-Finance Quoted other than lowest rate | |
| 4 | L4₹22.6 L+₹3.7 L (19.5%)Rejected-Finance 64 SHAHEED UDHAM SINGH MARKET NEAR OLD BUS STAND BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L4 | Rejected-Finance Quoted other than lowest rate |
Tender Value
₹24.5 L
EMD Value
₹49,000
Closing Date
21 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Sachin H Chavan IDSE
Garrison Engineer (North) Bathinda Mil Stn
PROVN OF SEWAGE TANK AND CERTAIN REV WORKS IN AREA UNDER AGE BR-III AND AGE EM-V OFFICE OF GE NORTH BATHINDA AT BATHINDA MIL STN
2020_MES_396918_1
8935/NIT-36/20-21
Open Tender
Civil Works
Item Rate
184 days
GE North Bathinda Mil Stn
Class E
9 documents required · 9 mandatory
₹500
Yes
GE (North) Bathinda
₹49,000
Yes
12 Jan 2021
21 Nov 2020
23 Dec 2020
21 Nov 2020
21 Dec 2020
8 Dec 2020
21 Nov 2020 - 27 Nov 2020
60 days
Amount
Surface dressing not exceeding 15cm deep in soft/ loose soil including cutting of grass, roots, bushes if any and filling of lower portion with soil obtained from cutting and excavation after sepration of grass, roots, bushes etc and dressing and removing from site all grass, roots and extra soil if any complete all as specified and as directed by Engineer-in-Charge.
Excavation in post holes in soft/loose soil n. exc 0.50 cum each, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc 25 cm including removing of surplus spoil to a distance n exc 50 mtr and making good the disturbed surfaces all as specified and directed by Engineer-in-Charge.
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundations, shafts, wells, cess pits, manholes, for taking out old pipe and laying new pipe line, for laying cable etc. not exceeding 10 Sqm on plan and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed by Engineer-in-charge.
Excavation in trenches, not exceeding 1.5 m wide and exceeding 1.5 m but not exceeding 3m in depth for foundations, shafts, wells, cess pits, manholes, for taking out old pipe and laying new pipe line, for laying cable etc. not exceeding 10 Sqm on plan and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed by Engineer-in-charge.
Excavation over areas, not exceeding 1.5mtr deep and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Excavation over areas, exceeding 1.5mtr and not exceeding 3mtr deep and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Excavation over areas, exceeding 3mtr and not exceeding 4.5mtr deep and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Excavation over areas, exceeding 4.5mtr and not exceeding 6mtr deep and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Labour for earth removing and filling under floor/plinth, spreading, levelling in layers n exc. 25 cm thick (each layer) consolidating the surface with Durmat/hand roller, rolling to required gradient and camber and upto entire satisfaction of Engineer-in-charge including levelling, well ramming including watering as required and consolidation complete all as specified and directed by Engineer-in-Charge. Note :- Extra Earth obtain from excavation (same site) shall be re-used.
Returning and filling including spreading, leveling watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Removing excavated material (surplus soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed by Engineer-in-charge.
Material and labour for hard core of broken bricks of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified & directed by Engineer-in- charge.
Demolition of cement concrete (unreinforced) in first floor, ground floor and paving not exceeding 15cm thickness below or above ground level of any description and in any position including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge
Material and labour for 75 mm thick PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in flooring, hard standing, plinth protection/path etc. finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for PCC (1:3:6), type C-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete, bed block, for embedded fencing posts & similar work etc including form work complete all as specified and as directed by Engineer-in-charge.
Material and labour for 75mm thick cement concrete ( 1:4:8), type D-2 using 40 mm graded stone aggregate as in sub base complete all as specified and as directed by Engineer-in-charge.
Material and labour for PCC ( 1:4:8), type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed by Engineer-in-charge.
Material and labour for PCC (1:2:4), type B-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete, sub base of sewage tank & similar work etc complete all as specified and as directed by Engineer-in-charge.
Material and labour for PCC (1:2:4), type B-1 using 20 mm graded stone aggregate as in foundation filling and mass concrete, bed block, for embedded posts & similar work etc complete all as specified and as directed by Engineer-in-charge.
Material and labour for PCC (1:2:4), type B-1 using 20 mm graded stone aggregate as bed block, cills, seismic and other similar bands & similar work etc above ground complete all as specified and as directed by Engineer-in-charge.
Material and labour for 25mm thick cement concrete (1:2:4), type B-0 using 12.5 mm graded stone aggregate as in sub base of floor for leveling course, surface finished rough to recieved tile/Kota stone/PCC floor work complete all as specified and as directed by the Engineer-in-Charge. (NOTE : Tile/Kota stone/PCC floor work shall be measured and paid separately under appropriate item of this schedule.
Material and labour for 25mm thick cement concrete (1:2:4), type B-0 using 12.5mm graded stone aggregate as in flooring, hard standing etc, and surface finished even & smooth without using extra cement including necessary form work complete all as specified and as directed by Engineer-in-charge.
Material and labour for 25mm thick cement concrete (1:2:4), type B-1 using 20 mm graded stone aggregate as in flooring, hard standing etc, and surface finished even & smooth without using extra cement including necessary form work complete all as specified and as directed by Engineer-in-charge.
Material and labour for 40mm thick cement concrete (1:2:4), type B-1 using 20 mm graded stone aggregate as in flooring, hard standing etc, in panels size as directed with provision of dividing strips and surface finished even & smooth without using extra cement including necessary form work complete all as specified and as directed by Engineer-in-charge. NOTE : Dividing strips shall be measured and paid separately under appropriate item of BOQ.
Material and labour for 40mm thick cement concrete (1:2:4), type B-1 using 20 mm graded stone aggregate as in sub base of floor of incenerator etc, and surface rough finished including necessary form work complete all as specified and as directed by Engineer-in-charge.
Material and labour for 50mm thick cement concrete (1:2:4), type B-1 using 20 mm graded stone aggregate as in flooring, flooring of sewage tank etc, and surface finished even & smooth without using extra cement including necessary form work complete all as specified and as directed by Engineer-in-charge.
Supply & fixing 1.5mm thick, 38mm wide PVC dividing strips inserted in position to the required design/ pattern all as specified & directed by Engineer-in- charge
Material and labour for 40 mm thick damp proof course in cement concrete (1:2:4) type B0 using 12.5mm graded stone aggregate) to horizontal or vertical surfaces including necessary form work and including mixing of liquid WPC in mortar @ 200ml per bag of cement of 50kg, complete all as specified and as directed by Engineer-in- charge. (Note :- WPC shall be measured & paid separately as Supply only)
Demolition of brick work or stone / boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, in any description including cleaning and stacking serviceable brick for re use and balance removing rubbish from the site complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work with sub class ‘B’ old size burnt clay bricks, straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work with sub class ‘B’ old size burnt clay bricks, straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:4) complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work using sub class 'B' old size bricks in one brick thick honey combing wall built in cement mortar (1:4) complete all as specified & directed by Engineer-in- charge.
Material and labour for brick work using sub class 'B' old size bricks in brick-on-edge walls (less than ½ brick thick), built in cement mortar (1:4) complete all as specified & directed by Engineer-in- charge.
Material and labour for Loose filling with broken bricks aggregates of gauge 40 to 80 mm in soakage pits, soakage wells complete all as specified & directed by Engineer-in- charge.
Material and labour for brick work with Fly Ash bricks (old size ), straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work in half brick thick wall using Fly Ash bricks (old size bricks) straight or curved on plan to any radius built in cement mortar (1:4) complete all as specified and as directed by Engineer-in- charge.
Form work to flat sides and soffits of floor or roof beams, beam haunchings , lintels, cantilevers, shelves including supports, overhangs, sides of chajjas etc and similar works rough finished flat surfaces complete all as specified & directed by Engineer-in- charge.
Form work to soffits of suspended slabs such as flat roof slabs, floor slabs, shelf slab, landings and similar work not exceeding 200mm thick (horizontal or sloping) rough finished complete all as specified and as directed by Engineer-in- charge.
Form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide, rough finished surfaces of concrete complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete reinforced of any discription and in any position, like slabs, shelves and similar suspended works, including reinforcement cut as required to facilitate demolition and prepare the surface to casting slabs/shelves and removing rubbish materials from site and deposited as directed complete all as specified and as directed by Engineer-in-charge
Material and labour for reinforced cement concrete (1:2:4) (nominal mix) type B-1 using 20mm graded stone aggregate as in beams, cantilevers, bressummers., lintels, cills, steps; seismic and other similar bands complete all as specified and as directed by Engineer-in-Charge. (NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
Material and labour for reinforced cement concrete (1:2:4) (nominal mix) type B-1 using 20mm graded stone aggregate as in slabs supported on walls, beams and columns landing, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by Engineer-in-Charge. (NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
Material and labour for mild steel TMT bars 10mm dia and over cut to length bent to shape, required including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge. (NOTE : Weight of binding wire shall not be considered for measurement and payment purpose.)
Material and labour for mild steel TMT bars 6 mm to 8mm dia cut to length bent to shape, required including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge. (NOTE : Weight of binding wire shall not be considered for measurement and payment purpose.)
Material and labour for mild steel TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders cut to length, bent to shape required including bending, cranking etc and binding with and including MS wire (annealed) not less than 0.9mm dia, complete all as specified & directed by Engineer-in- charge. (NOTE : Weight of binding wire shall not be considered for measurement and payment purpose)
Material and labour for mild steel work as in bands, rings, steps in manhole/soakage well, hooks handles manhole covers, hold fast and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed by Engineer-in- charge.
Taking down cement or cement lime plaster from brick wall etc including racking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for plastering 15mm thick in cement mortar (1:6) on any face of Brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for plastering 10mm thick in cement mortar (1:6) on any fare face of Brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for rendering/plastering 15mm thick in cement mortar (1:4) on any face of Brick walls or concrete surfaces including mixing of liquid WPC in mortar @ 200ml per bag of cement of 50kg, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge. (Note :- Water proofing compound shall be measured & paid separately as Supply only)
Material and labour for rendering/plastering 15mm thick in cement mortar (1:4) on any face of Brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for rendering/plastering 12mm thick in cement mortar (1:3) on fare face of Brick walls (sewage tank) or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for plastering 5mm thick in cement mortar (1:3) on any face of ceiling, finished fair and even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Keyed pointing in cement mortar (1:3) to brick walls surfaces, complete all as specified and as directed by the Engineer-in-Charge.
Supply only liquid water proofing compound complete all as specified and as directed by the Engineer-in-Charge. Make : Dr Fixit/Fosroc/BASF/STP
Supply and fixing 60 mm thick (M35 grade) precast interlocking tile/paving block factory casted (made by using PVC paver mould / Rubber paver moulds on Vibrating Table Machine) using grey cement and no pigment, shape haxagon / trigular / zigzag / I-shaped etc, as directed, prepolished & preglazed, specification as per relevant IS, having compressive strength not less than 350 Kg/ Sqcm, laid over sand upto required thick layer and filling the interstices etc complete all as specified and as directed by the Engineer-in-Charge. Note : - (i) Sand for filling shall be measured & paid separately as Supply only but labour for spreding leveling shall be included in the unit rate of this item)
Supply only fine sand without silt (Fazilka/Zera or any other approved sources) for filling under interlocking tiles and the interstices etc complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for PCC (1:3:6), type C-1 using 20 mm graded stone aggregate as in coping/packing around chequered tiles/interlocking tiles/PCC jalli, surface chanel & similar work etc complete all as specified and as directed by Engineer-in-charge.
Material and labour for precast cement concrete (1:2:4) type B1 using 20mm graded stone aggregate in kerb stone, quoin blocks, copings, kneelers, apex stones, boundary pillars, bed plates, bonders ( for stone walling), etc with plain fair faces, chamfers, weatherings, slightly rounded or chamfered angles and throating etc including form work and laying and setting in cement mortar (1:4) including dismantling of old damaged kerb stone and removing the debris from site all as directed.
Demolition of floor hearth or wall tilling including cement mortar bedding but not backing including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge
Material and labour for Digital glazed ceramic coloured tiles 7 to 8mm thick, rectangular area of each tile 300x600mm, as in vertical surface such as skirting, dado etc. set and jointed in neat cement slurry over and including 10 mm thick bedding layer (rendering) in cement mortar (1:4) and pointed in white or coloured cement to match the shade of tile, including necessary cutting as per site requirement, complete all as specified and directed by Engineer-in-Charge.
Material and labour for Digital glazed ceramic coloured tiles (as highlighter) 7 to 8mm thick, rectangular area of each tile 300x600mm, as in vertical surface such as skirting, dado etc. set and jointed in neat cement slurry over and including 10 mm thick bedding layer (rendering) in cement mortar (1:4) and pointed in white or coloured cement to match the shade of tile, including necessary cutting as per site requirement, complete all as specified and directed by Engineer-in-Charge.
Material and labour for Glazed ceramic coloured tiles of size 350mmx 250mm / 450mmX 350mm, 7mm thick, as in vertical surface set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 10 mm thick (Av thickness) bedding layer (rendering) in cement mortar (1:4) complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Non Skid ceramic coloured tiles 7 to 8 mm thick square or rectangular area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 15 mm thick bedding layer (screed) in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
Material and labour for Non Skid ceramic coloured tiles 7 to 8mm thick square or rectangular area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 15 mm thick bedding layer (screed) in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
Material and labour 18-20mm thick machine cut, granite duly factory grinding and polished (table rubbed and polished) of approved colour for counter sunk wash basin, plateform/cooking plateform or as directed, including screed bed 15mm thick in cement mortar (1:4) (grey cement slurry) including pointing in white cement (1:2) using marble dust with admiture of pigment to match with shade of granite stone slab including cutting as required including cleaning and extra polishing if required complete all as specified and as directed by Engineer-in-Charge.
Material and labour for moulding the edges half round on exposed side (Rounding to edges of stone slabs one edge) of granite/marble as in kitchen shelf, cooking platform, WHB counter shelf, steps, and other similar situations etc complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames, wooden/PVC doors/steel ventilator) area not exceeding 1.50 sqm each and removing from site including cutting holes for removal of old rusted hold fast and prepare the surface for new hold fast complete all as specified and as directed by Engineer-in- charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4 Sqm each and removing from site including cutting holes for removal of old rusted hold fast and prepare the surface for new hold fast complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 12mm thick Prelaminated particle board, exterior grade, prelaminated both sides with decorative choice lamination, fixed with screws/nails/fevicol to timber frame work including cutting and made to shape as required complete all as specified & directed by Engineer-in- charge.
Supply and fixing 18-20mm thick block board (grade 2, interior grade quality), commercial type fixed with screws/nails/fevicol including cutting and made to shape as required complete all as specified & directed by Engineer-in- charge.
Supply and fixing plain fillets made from second class soft wood square, rectangular or trangular in section, clean sawn, sectional area exc 3 sqcm and n exc 6 sqcm fixed to timber frame with nails complete all as specified & directed by Engineer-in- charge.
Supply & fixing Continuous (piano) hinges, mild steel, bright finish or electro galvanised, width of flap when open 30mm complete all as specified and as directed by Engineer-in-charge .
Supply & fixing brass Drawer handles, projection drop (50mm to 65mm) on screwed plate complete all as specified and as directed by Engineer-in-charge .
Supply and fixing solid PVC door frame of size 50mm x 47mm made out 5mm thick plain clour PVC sheet reinforced with MS square tube including painting of edges to match with sheet, all as specified & shown in relevant drawing of item No. 8095 in MES Schedule SSR-2010 (Part-II), fixed in opening complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing factory made solid core PVC door shutter 30mm thick (stiles) consisting of frame made out of MS tubes of 19mm gauge thickness and size of 19mmx19mm for stiles and for top and bottom rails 15mmx15mm. MS frame shall have a coat of red oxide primer of approved make and shall be covered with heat moulded plain colour PVC sheet, 'C' channel of size 30x50mm forming stiles and 5mm thick wide PVC sheet strip of 20mm width stuck inside with solvent cement for stiles, and plain colour PVC sheets for top rail, lock rail & bottom rail on either side and 10mm (5x2mm) thick, 20mm thick PVC sheet to be fitted in MS frame welded/ sealed to the stiles and rails with 30mm wide x 5mm thick PVC sheet beading on either side and joined together with solvent cement adhesive and an additional 5mm thick PVC strips of 20mm width is to be stuck on interior side of C channel using PVC solvent adhesive as per manufacturer's instructions, door to be fixed to frame with and including 3 Nos MS powder coated butt hinges of size 100mm long x 25mm wide and 2mm thick and fixing with 32mm long steel screws drilled suitable to pass through both the walls of the MS tube complete all as specified in SSR-2009 (Part-I, specifications) & shown in relevant drawing of item No. 8080 in SSR-2010 (Part-II, rates). The width of stiles & rails will be in proportion to the width of the door shutter as specified in SSR-2010 (Part-II). complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing aluminium anodised frame, made out of aluminium section weighing 0.98 Kg/mtr, for doors, windows, ventilators with one or more rebate including jointing cleat for fixing etc. complete all as specified and directed by Engineer-in-Charge. Note :- If aluminium section used other than above mentioned weighing then weight of each section shall be physically ascertained through a board of officers convened by Accepting officer and payment shall be made only after the actual weight at site.
Supply & fixing anodised aluminium door shutter, made out of aluminium section weighing 0.55 Kg/mtr, including aluminium hardware i.e. necessary joining cleats, glazing clips, rubber neoprene packing, suitable size of aluminium handles 2 Nos and aluminium hinges 04 Nos in each leaf (size of handle and hinge as directed), anodised aluminium snap beading, screws etc including fixing of glass, complete all as specified and directed by Engineer-in-Charge. Note :- (i) Aluminium chowkhat frame shall be measured and paid separately under appropriate item of BOQ as supply and fixing. (ii) Glass and other filling material in panels shall be measured and paid separately under appropriate item of BOQ as supply only.
Supply & fixing anodised aluminium window/ventilator shutter side hung type without sash bars, made out of aluminium section weighing 0.55 Kg/mtr, including necessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.), hinges type B-21 100mm long (2 No. for ventilator and 3 Nos for window each shutter) suitable handle (1 No.), including fixing of glass, complete all as specified and directed by Engineer-in-Charge. Note :- (i) Aluminium chowkhat frame shall be measured and paid separately under appropriate item of BOQ as supply and fixing. (ii) Glass and other filling material in panels shall be measured and paid separately under appropriate item of BOQ as supply only.
Supply & fixing anodised aluminium window/ventilator fixed type without sash bars, made out of aluminium section weighing 0.55 Kg/mtr, including necessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading, screws etc. including fixing of glass, complete all as specified and directed by Engineer-in-Charge. Note ;- Glass (supply only) shall be measured and paid separately under appropriate item of BOQ.
Supply & fixing 150mm long Floor door stopper of brass body and tongue with hard drawn steel spring, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing anodised aluminium handle cast type 150mm long complete all as specified & directed by Engineer-in-charge.
Supply and fixing aluminium anodised barrel tower bolt of extruded section, 150mm long complete all as specified & directed by Engineer-in-charge.
Supply & fixing mild steel 4 lever mortice lock vertical type 100mm size with original and duplicate key complete all as specified and directed by Engineer-in-Charge.
Supply & fixing aluminium (extruded section) body door closer hydraulically regulated, designation No 3, universal type suitable for door shutter of 851 to 1000mm in width and weight between 61 to 80 Kg, ISI marked complete all as specified & directed by Engineer-in-charge.
Supply only 4 mm thick sheet glass ordinary quality in squares not exceeding 0.5sqm in each pane complete all as specified & directed by Engineer-in- charge. Note :- Labour for fixing shall be included in the main item of shutters.
Supply & fixing, 4mm thick frosted eatched (one side) in squares exceeding 0.5sqm in each pane complete all as specified & directed by Engineer-in- charge.
Supply & fixing, solar control film 25 micron reflective type (gareware sun control or equivalent) pasting on glass duly air bubble free complete all as specified & directed by Engineer-in- charge.
Supply and fixing in replacement stainless steel chromium plated pipe 25mm dia, wall thickness of pipe not less than 20 guage, as curtain rod fixing with and including fancy type brackets and decorated end knobs (finials), stop roller etc, fixed on wall for doors and windows curtains, cuttings as required length and fixing at site including fixing arrangements, rawl plug, screws etc. including taking out old any type rod or pelmet boxes with curtain rod complete all as specified & directed by Engineer-in- charge.
Taking up or down existing galvanised steel water tubing (GI pipe) 15mm bore including fitting/connection from wall/ceiling/floor/concealed etc. complete all as specified and as directed by Engineer-in-charge.
Taking up or down existing galvanised steel water tubing (GI pipe) 20mm bore including fitting/connection from wall/ceiling/floor/concealed etc. complete all as specified and as directed by Engineer-in-charge.
Supply and fixing galvanized steel tubing (GI pipe) medium grade 15mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling and laid in floor or concealed in walls including cutting chases in wall (as directed ) and making good disturbed surfaces of walls including cutting and threading of pipe complete all as specified and as directed by Engineer-in- charge.
Supply and fixing galvanized steel tubing (GI pipe) medium grade 20mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling and laid in floor or concealed in walls including cutting chases in wall (as directed) and making good disturbed surfaces of walls including cutting and threading of pipe complete all as specified and as directed by Engineer-in- charge.
Supply and fixing galvanized steel tubing (GI pipe) medium grade 25mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling and laid in floor or concealed in walls including cutting chases in wall (as required) and making good disturbed surfaces of walls including cutting and threading of pipe complete all as specified and as directed by Engineer-in- charge.
Dismantling cast iron drain pipes, jointed in cement mortar of any description any dia from wall and taking out from trenches including all fittings (bend, trap, cowl, branch piece etc) and removing from the site complete all as directed by Engr-in-Charge.
Material & Labour for 100 mm bore cast iron soil waste and vent pipe (sand cast pipe ) in any length with or without ears, fixed vertical (embeded in RCC slab ) complete all as specified and as directed by Engineer-in- charge.
Material & Labour for 100 mm bore cast iron soil waste and vent pipe (sand cast pipe ) in any length with or without ears, fixed to wall with stack clamps (interval of 1m) made out of FI 50x5mm and 16mm dia round iron stay including nut bolt and jointing with cement mortar complete all as specified and as directed by Engineer-in- charge.
Material & Labour for 100 mm bore cast iron soil waste and vent pipe (sand cast pipe ) in any length with or without ears, laid in trenches or in floor jointing with cement mortar complete all as specified and as directed by Engineer-in- charge.
Material & Labour for 75 mm bore cast iron soil waste and vent pipe (sand cast pipe ) in any length with or without ears, fixed to wall with stack clamps (interval of 1m) made out of FI 50x5mm and 16mm dia round iron stay including nut bolts and jointing with cement mortar complete all as specified and as directed by Engineer-in- charge.
Material & Labour for 75 mm bore cast iron soil waste and vent pipe (sand cast pipe ) in any length with or without ears, laid in trenches or in floor jointing with cement mortar complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 100mm bore cast iron bends (any radius)/elbo, diminishing pieces or tapers (larger bore measured) with oval access door fixed with cement joints complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 75mm bore cast iron bends (any radius)/elbo, diminishing pieces or tapers (larger bore measured) with oval access door fixed with cement joints complete all as specified and as directed by Engineer-in- charge.
Supply and fixing Cast iron floor trap 100mm bore, with CP grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) using 20mm graded stone aggregate complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 100 mm cast iron sanitary connection socket to fit out let of WC complete all as specified and directed by Engineer-in-Charge.
Supply & fixing 100mm bore CI branch pieces single (equal or unequal), ordinary or inverted (Spigot or socket type) or with parallel branch fitted with oval access door as specified & directed by Engineer-in- charge.
Supply & fixing 100mm bore cast iron cowl complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints for drain or rain water fixed along walls with stack clamps made out of FI 50x5mm and 16mm dia round iron stay (interval of 1m) including PCC work, complete all as specified and as directed by Engineer-in- charge.
Supply & fixing PVC (SWR) bends (any radius) suitable for 110mm bore pipe fixed to walls or laid in floor complete all as specified and as directed by Engineer-in- charge.
Supply & fixing PVC (SWR) bends (any radius) suitable for 75mm bore pipe fixed to walls or laid in floor complete all as specified and as directed by Engineer-in- charge.
Supply & fixing PVC (SWR) vent cowl suitable for 110mm bore PVC pipe complete all as specified and as directed by Engineer-in- charge.
Supply & fixing PVC (SWR) floor trap suitable for 100/110mm bore pipe, plain with grating including jointing with solvent cement complete all as specified and as directed by Engineer-in- charge.
Supply and fixing 150mm x 150mm size salt glazed stone ware gully traps, square or round mouthed, type 'P' complete all as specified and as directed by Engineer-in- charge.
Material and labour pre-cast RCC (1:2:4) B-1 using 20 mm graded crushed stone aggregates as in pre-cast manholes cover slabs of any thickness size and shape including all necessary form work, finishing concrete surface fair and even and set in CM (1:4) at site as directed complete all as specified and directed by Engineer-in-Charge. (NOTE : Reinforcement shall be measured and paid separately under appropriate item of this schedule.
Material and labour cutting into existing manholes/septic tank for connecting new drain upto 150mm internal dia, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round to 3/4 section) in cement concrete (1:2:4) type B-1 smooth finished, and reforming benching as required complete all as specified & directed by Engineer-in-charge.
Material and labour for moorum/red bajri bed to DWC drain pipes, spread/laid in trenches in layers not exceeding 15cm thick, levelled and rammed including watering complete all as specified and directed by Engineer-in-Charge.
Supply and laying DWCPE (SN8) drain pipes 150mm inner dia as per IS-16098 (Part-II), laid in trenches on moorum bed to required slope, including all accessories/fittings/jointing ring, jointing and tested complete all as specified and as directed by Engineer-in-Charge. Make :- Rex Polyextrusion Limited/Dura line/ Alom Poly Extrusions Ltd/Jain Irrigation/Kamboj Polythene Ltd Ludhiana/Aspra Industries Delhi (Note : Excavation, earth work and Moorum bed shall be measured & paid separately under appropriate item of this BOQ)
Supply and laying DWCPE (SN8) drain pipes 200mm inner dia as per IS-16098 (Part-II), laid in trenches on moorum bed to required slope, including all accessories/fittings/jointing ring, jointing and tested complete all as specified and as directed by Engineer-in-Charge. Make :- Rex Polyextrusion Limited/Dura line/ Alom Poly Extrusions Ltd/Jain Irrigation/Kamboj Polythene Ltd Ludhiana/Aspra Industries Delhi (Note : Excavation, earth work and Moorum bed shall be measured & paid separately under appropriate item of this BOQ)
Supply & fixing vitreous China squatting pan 'Orissa' pattern white of size 580mmx440mm white with integral foot rests, excluding flushing cistern, flush pipe above floor but including PVC (SWR) 'P' trap 100/110mm bore and including setting the trap and pan in lime concrete (1 lime, 2 sand or surkhi and 5 aggretate), min. 150mm thick all round and finished just below level of rim of pan to receive the floor finishing, including PVC flush pipe upto finished floor level, joints of flush pipe and trap make leakproof and testing upto entire satisfaction of Engineer-in-charge before filling concrete complete all as specified and as directed by Engineer-in- charge.
Supply & fixing vitreous china wash down water closet pan (pedestal pattern, EWC) white clour (excluding flushing cistern and flush pipe) including connection to drain and to flushing pipe anti syphonage etc., including plastic water closet seat with cover (white or black colour) closed pattern with flat bottom and mild steel chromium plated or aluminised hinging device including stainless steel chromium plated jet spray with 01 mtr long PVC pipe with CP connector and necessary nut bolts and with necessary CP screws and plug for fixing WC complete all as specified and as directed by Engineer-in- charge.
Supply and fixing hand shower (health faucet) ABS body including 1 meter long 8mm dia flexible tube and including wall hook including taking down old any type shower complete all as specified and as directed by Engineer-in-charge. Make :- Cat Part ALD-CHR-593N of Jaquar or equivalent (Equivalency approved by GE) in make mentioned in Appx A to PSS-II
Supply & fixing in replacement plastic water closet seat with cover (white colour) closed pattern with flat bottom/recessed bottom and mild steel chromium plated or aluminised hinging device complete all as specified and as directed by Engineer-in- charge.
Supply and fixing 10 litres capacity PVC valveless syphonic action type low level flushing cistern white with inlet, ball valve, float, handle including brackets and 32mm dia PVC bend long type ( flush pipe) complete all as specified and directed by Engineer-in-Charge.
Supply & fixing Single Piece Slim Concealed Cistern Body with Installations Kit & “S-Type” drain pipe connection set for Wall Hung WC including Control Plate Opal complete all as specified and as directed by Engineer-in-Charge. Make :- Cat Part JCS-WHT-2400S (cistern) and JCP-CHR-152415 (Control plate) of Jaquar or equivalent (Equivalency approved by GE) in make mentioned in Appx A to PSS-II
Supply & fixing Rimless Wall Hung WC Size:370x545x370 mm with UF soft close seat cover, Hinges, Accessories Set, including complete fixing accessories complete all as specified and as directed by Engineer-in-Charge. Make :- Cat Part DRS-WHT-37951 of Jaquar or equivalent (Equivalency approved by GE) in make mentioned in Appx A to PSS-II Note :- Cistern with fittings shall be measured and paid separately under appropriate item of BOQ.
Supply & fixing vitreous china wash basin, white, flat back of size 550mm x 400mm, including 32mm chromium plated waste coupling and PVC waste pipe including bracket and cutting for and pinning in end of bracket or erecting including fixing only pillar tap complete all as specified and as directed by Engineer-in-Charge. (Note :- Pillar tap shall be measured & paid separately as Supply only under appropriate item of BOQ.)
Supply & fixing vitreous china wash hand basin oval type under counter, white colour, of size 595mm x 420mm x 200mm excluding taps, but including fancy type 32mm waste coupling and waste pipe, fixing/counter sunked in granite slab, complete all as specified and as directed by Engineer-in-Charge. Note :- Granite slab shall be measured and paid separately under appropriate item of BOQ. Make :- Cat Part CNS-WHT-705 of Jaquar or equivalent (Equivalency approved by GE) in make mentioned in Appx A to PSS-II
Supply & fixing in replacement vitreous china urinal, half stall type, white, including providing and fixing plugs, bedding urinal against wall in cement mortar (1:2), securing urinal to plugs with and including 60mm long brass screws, 32 mm dia full threaded PTMT waste coupling and 32mm dia waste pipe and pointing around urinal back in cement mortar, including taking down old urinal with fittings complete all as specified & directed by Engineer-in-charge.
Supply & fixing vitreous china urinal, half stall type, white, including providing and fixing plugs, bedding urinal against wall in cement mortar (1:2), securing urinal to plugs with and including 60mm long brass screws, 32 mm dia full threaded PTMT waste coupling and 32mm dia waste pipe and pointing around urinal back in cement mortar complete all as specified & directed by Engineer-in-charge.
Supply & fixing Towel Rail 450mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Toilet Roll Holder with Stainless Steel Flap, fixed on wall with chromium plated brass screws and PVC plug complete, all as specified and as directed by Engineer-in-charge. Make :- Cat Part AKP-35753PS of Jaquar or equivalent (Equivalency approved by GE) in make mentioned in Appx A to PSS-II
Supply and fixing soap dish holder, fixed on wall with chromium plated brass screws and PVC plug complete all as specified and as directed by Engineer-in-charge. Make :- Cat Part AQN-7731 of Jaquar or equivalent (Equivalency approved by GE) in make mentioned in Appx A to PSS-II
Supply and fixing Towel Ring Round, fixed on wall with chromium plated brass screws and PVC plug complete all as specified and as directed by Engineer-in-charge. Make :- Cat Part AQN-7721 of Jaquar or equivalent (Equivalency approved by GE) in make mentioned in Appx A to PSS-II
Supply and fixing Towel Rail (Single) 600mm long between flanges, fixed on wall with chromium plated brass screws and PVC plug complete all as specified and as directed by Engineer-in-charge. Make :- Cat Part AQN-7711 of Jaquar or equivalent (Equivalency approved by GE) in make mentioned in Appx A to PSS-II
Supply and fixing in replacement Glass shelf 550mm long complete all as specified and as directed by Engineer-in-charge. Make :- Cat Part AQN-7771 of Jaquar or equivalent (Equivalency approved by GE) in make mentioned in Appx A to PSS-II
Supply and fixing corner Glass shelf with bracket including taking down old any type shelf complete all as specified and as directed by Engineer-in-charge. Make :- Cat Part ACN-1173 of Jaquar or equivalent (Equivalency approved by GE) in make mentioned in Appx A to PSS-II
Supply and fixing liquid soap dispenser with glass bottle, fixed on wall with chromium plated brass screws and PVC plug complete all as specified and as directed by Engineer-in-charge. Make :- Cat Part CAN-1135N of Jaquar or equivalent (Equivalency approved by GE) in make mentioned in Appx A to PSS-II
Supply and fixing frosted glass of 6mm thick slected quaility for partition of urinal or WC area including fixing accessorioes aluminium cleats, screws, plug etc. complete all as specified and as directed by Engineer-in-charge.
Supply and fixing bib tap cast copper alloy, chromium plated, fancy type with crutch or butterfly handle with capstan head, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.
Supply and fixing stop valve/angle valve cast copper alloy, with crutch or butterfly handle, screwed down, screwed both end for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.
Supply and fixing concealed stop cock cast copper alloy, chromium plated, fancy type, long shank and cup, screwed both ends suitable for 15mm bore iron pipe complete, all as specified & directed by Engineer-in-charge. Note :- The minimum weight of stop valve/stop cock shall be as given in SSR or in relevant IS.
Supply only pillar tap cast copper alloy with capstan head, chromium plated, high pressure with or without letter 'Hot' or 'Cold' with long shank and fly nuts screwed for iron pipe or for brass ferrule 15mm bore complete, all as specified & directed by Engineer-in-charge. Note :- The minimum weight of tap shall be as given in SSR or in relevant IS
Supply & fixing in replacement Pillar taps, cast copper alloy, with capstan heads, chromium plated, fancy type screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts screwed for iron pipe or for brass ferrule 15mm bore complete, all as specified & directed by Engineer-in-charge. Note :- The minimum weight of tap shall be as given in SSR or in relevant IS
Supply & fixing cromium plated shower rose 125mm size, with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed by Engineer-in-charge.
Supply & fixing 450 mm long PVC connection 15mm size with PTMT nuts complete all as specified & directed by Engineer-in-charge.
Supply & fixing rotational moulded polyethylene water storage tank white colour of capacity 500 litres (cylindrical vertical, triple layered with closed top), hoisted and fixed in position including making inlet and out let connection and fixing ball valve and gate valve including dismantling/taking down of existing unserviceable PVC water storage tanks of any description complete all as specified and as directed by Engineer-in-charge. (Note :- Float valve and gate valve shall be measured & paid separately as Supply only under appropriate item of BOQ.)
Supply & fixing rotational moulded polyethylene water storage tank white colour of capacity 1000 litres (cylindrical vertical, triple layered with closed top), hoisted and fixed in position including inlet and out let connection and fixing ball valve and gate valve complete all as specified and as directed by Engineer-in-charge. (Note :- Float valve and gate valve shall be measured & paid separately as Supply only under appropriate item of BOQ.)
Supply only ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball (polythene float) complete, screwed suitable for 25mm bore iron pipe complete all specified and as directed by Engineer-in-charge. Note :- The minimum weight of ball valve shall be as given in SSR or in relevant IS.
Supply only ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball (polythene float) complete, screwed suitable for 20mm bore iron pipe complete all specified and as directed by Engineer-in-charge. Note :- The minimum weight of ball valve shall be as given in SSR or in relevant IS.
Supply only gun metal, globe or gate valve (ISI marked), brass cast copper alloy, with iron wheel head, screwed both ends suitable for 20mm bore iron pipes complete all as specified and as directed by Engineer-in-charge. Note :- The minimum weight of gate valve shall be as given in SSR or in relevant IS.
Supply only gun metal, globe or gate valve (ISI marked), brass cast copper alloy, with iron wheel head, screwed both ends suitable for 25mm bore iron pipes complete all as specified and as directed by Engineer-in-charge. Note :- The minimum weight of gate valve shall be as given in SSR or in relevant IS.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets any thickness including cover fillets fixed in any position with nails fixed with screws complete all as specified and as directed by Engineer-in-charge.
Supply and fixing anodised aluminium snap grid frame work of size of grid 605 x605mm for false ceiling including necessary notching and prepared holes, the snap grid shall consist of anodised aluminium main tee of size 36.5mm x 25mm x 1.4mm weighing 0.24 Kg/RM, cross and Intermediate tee of size 23.5mm x 26.4mm x 1.4mm weighing 0.191 Kg/RM. The main and cross tee shall be jointed at junction with steel screws or MS bolts, nuts and washers, the snap grid (main / cross tee sections) shall be supported at ends all along the wall with anodised aluminium angle of size 35mm x25mmx 2mm weighing 0.36 Kg/RM fixed to wall with suitable arrangement and duly suspended with 4mm GI wire hangers (upto 1200 mm length) adjusting level fixed to roof slab by means of ceiling cleats made of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long including providing 12mm thick gypsum board in grid fixed in false ceiling grid made of aluminium as per above specifications complete all as specified and as directed by Engineer-in-charge.
Material and labour for 10mm thick plaster of paris ceiling (Gypsum anhydrous) to flat surface over 2nd class soft wood fillets or metal frame work and reinforced with and including GI wire mesh complete all as specified and as directed by Engineer-in-charge. Note : - Fillets shall be measured and paid separately.
Supply and fixing Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engineer-in-charge.
Material and labour for mild steel framed work, framed/truss work for fixing GI sheets (design for framing as directed by Engineer-in-charge) and using hollow square/rectangular pipe, or other section like angle, tee, plate, distance pieces, cleats etc. and cut to shape, drilled and counter sunk for screw, as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and fixed with angle cleats or other connecting plates, gusset plates, brackets, bending and welding, riveting etc, conforming to Gde Fe-410-W (Gde E-250 quality A) complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for mild steel work tubular poles/post including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to latest relevant IS grade St-240 complete all as specified & directed by Engineer-in- charge.
Material and labour for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete including fabrication as directed, including hold fast, locking arrangement, sliding door bolt, stopper etc conforming to Fe-410-W (Gde E-250) quality A complete all as specified and as directed by Engineer-in- charge
Material and labour for preparation of new plastered surfaces of walls/pillars /cornices by brooming down with using broom/sand papering or by any other mean, washing down with water and applying two coats of cement base paint as per approved tint/colour by using paint brush complete all as specified and as directed by Engineer-in-Charge.
Material and labour for preparation of new plastered surfaces of walls/pillars /cornices by brooming down with using broom/sand papering or by any other means, and preparing the surfaces smooth by applying white cement based putty to make the surface even and smooth by using sander machine (with provision of dust sucking) upto entire satisfaction of Engineer-in-charge, and after preparing the surfaces applying two coats of oil emulsion distemper (washable), as approved tint/colour by using paint roller brush complete all as specified and as directed by Engineer-in-Charge.
Material and labour for preparation of new plastered surfaces of walls/pillars /cornices by brooming down or by sand papering or by any other mean and after preparing the surfaces applying three coats of white wash complete all as specified and as directed by Engineer-in-Charge.
Material and labour for preparing newly plastered or concrete surface of ceiling by sand papering or by any other mean and after preparing the surfaces applying three coats of white wash complete all as specified & directed by Engineer-in- charge
Material and labour for complete removal of existing treatment (any layers of existing treatment ) from walls/pillars/cornices by scraping down with using mechanical sander machine (including provision of dust sucking) upto entire satisfaction of Engineer-in-charge, brooming and washing down and preparing the surfaces smooth and after that applying average 3mm thick layer (1.5mm thick each in two layer application) of white cement based putty (wall care putty, make Birla JK or equvilent as approved by Engineer-in-charge), after applying putty first and second coat sanding the surface as per requirement by using mechanical sander machine to make the surface even and smooth upto entire satisfaction of Engineer-in-charge and after prepare the surface smooth applying two coats of oil bound distemper (washable) as per approved tint/colour by using paint brush or roller brush complete all as specified and as directed by Engineer-in-Charge. NOTE : - Each stage i.e after complete removal and before applying OBD as specified above, the surface shall be passed in writing by the Enigineer-in-charge.
Material and labour for preparation of new steel and iron surfaces of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed by Engineer-in- charge.
Material and labour for concealed Point wiring complete with 1.5 Sqmm (nominal cross section area) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC rigid conduit 20mm dia (heavy duty) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction box, Pressed steel powder coated sunken box of suitable size (Min 60mm deep, suitable length and made out of 1.6mm thick sheet) concealed in wall, 3mm thick bakelite plastic laminated hylem sheet for mounting of switches/socket/regulator with brass screws & cup washers, wiring for light /fan/ bell point controlled by one switch (on indipendent board), including provn of 1.5 Sqmm FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ).
All as per above Srl item No. 167 but for one socket out let 5/6 Amps point controlled by one switch (on same board) complete all as specified and as directed by Engineer-in-charge. (switches, sockets etc. shall be measured and paid separately under appropriate item of BOQ).
All as per above Srl item No. 167 but for one socket out let 5/6 Amps point controlled by one switch (on indipendent board and not below the any other switch board) complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ).
Material and labour for concealed Point wiring complete with 2.5 Sqmm (nominal cross section area) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC rigid conduit 20mm dia (heavy duty) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction box, Pressed steel powder coated sunken box of suitable size (Min 60mm deep, suitable length and made out of 1.6mm thick sheet), 3mm thick bakelite plastic laminated hylem sheet for mounting of switches/socket with brass screws & cup washers, wiring for one socket out let 15/16 Amps point controlled by one switch (on indipendent board), including provn of 2.5 Sqmm FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ).
Supply and fixing switch piano flush type (ISI marked) semi modular, 5/6Amps, single pole, one way fixed on laminated sheet complete all as specified and as directed by Engineer-in-charge. (Hylem sheet shall be measured and paid in point wiring item of BOQ).
Supply and fixing Socket outlet multipurpose type (ISI marked) semi modular, 2 in 1, 3/5 pin 5/6 Amp, flush type fixed on laminated sheet complete all as specified and as directed by Engineer-in-charge. (Hylem sheet shall be measured and paid in point wiring item of BOQ).
Supply and fixing switch piano flush type (ISI marked) semi modular, 15/16Amps, single pole, one way complete all as specified and as directed by Engineer-in-charge. (Hylem sheet shall be measured and paid in point wiring item of BOQ).
Supply and fixing Socket outlet multipurpose type (ISI marked) semi modular, 2 in 1, 3/5 pin 15/16 Amp, flush type fixed on laminated sheet complete all as specified and as directed by Engineer-in-charge. (Hylem sheet shall be measured and paid in point wiring item of BOQ).
Supply and fixing ceiling rose (ISI marked) surface type polycarbonate isolated body two to three terminal, topline series 20x50mm, 6 Amp, 250 volts, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing batten holder (ISI marked) polycarbonate cased body (B22 base), top line series, with back plate, 5/6Amps, 250 volts including LED lamp lumeno of 9 watt suitable for B-22 based holder complete all as specified and directed by Engineer-in-Charge.
Material and labour for concealed sub main wiring with 6 Sqmm single core (Two run) FRLSH PVC insulated multistrand copper conductor drawn through and including PVC conduit 20mm dia (medium quality ISI marked), on independent circuit from DB and including one run 6 Sqmm FRLSH PVC insulated unsheathed multi strand copper conductor continues as earth wire connected to earth dolly etc. including all fitting arrangement i.e. PVC clamp, rawl plug, screw, terminal/junction box, tee, bend etc. and including cutting of chases in wall, and making good disturbed surfaces of walls as per original complete all as specified and as directed by Engineer-in-charge. Note :-Three run of 6 sqmm copper wire and one run conduit shall be measured as one RM length for payment.
Material and labour for concealed sub main wiring with 4 Sqmm single core (Two run) FRLSH PVC insulated multistrand copper conductor drawn through and including PVC conduit 20mm dia (medium quality ISI marked), on independent circuit from DB and including one run 4 Sqmm FRLSH PVC insulated unsheathed multi strand copper conductor continues as earth wire connected to earth dolly etc. including all fitting arrangement i.e. PVC clamp, rawl plug, screw, terminal/junction box, tee, bend etc. and including cutting of chases in wall, and making good disturbed surfaces of walls as per original complete all as specified and as directed by Engineer-in-charge. Note :-Three run of 4 sqmm copper wire and one run conduit shall be measured as one RM length for payment.
Supply and fixing (concealed in wall or as directed) factory made DB (made out of CRCA sheet) SPN, 04 Way (04 modules) 230/240V, double door, earth bar, copper bus bar and neutral link, protection class IP-43 suitable for mounting MCB/Isolator, conforming to IS-8623, BS-5484 dust and vermin proof and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB’s shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing (concealed in wall or as directed) factory made DB (made out of CRCA sheet) SPN, 8 Way 240V, double door, earth bar, copper bus bar 200 Amp and neutral link, protection class IP-43 suitable for mounting MCB/Isolator, conforming to IS-8623, BS-5484 dust and vermin proof, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB’s shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing MCB ‘C’ curve suitable for 240 volts AC supply, 06 to 32 Amps, SP with over load and short circuit protection and rupturing capacity not less than 10 KA, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing MCB ‘C’ curve suitable for 240 volts AC supply, 40 Amps, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing wall mounted LED Batten T-8 Retro LED 18/20 watt (100 lumens per watt), appx 4 feet long, pre wired including LED tube light with in built driver, not less than 6000K, complete fitting and all other accessories fitting arrangements including electric connection complete all as specified and as directed by Engineer-in-Charge. Make - Cat part No BLRB 18W CWc and BLRB-DB 118 of Bajaj / LT8-20-865-2 and DMLN1 LT8-16 of Crompton / PHOTONULTRA 1213T8 SSTL 18W LED865SPC and REGALBATTENT 8UPTO 1X22W SSBSWH of Havells
Supply and fixing LED light fiting 9/10 watt (100 lumens per watt), appx 2 feet long with in built driver, complete fitting ready to use in all respect with tube rod and all other accessories fitting arrangements including electric connection complete all as specified and as directed by Engineer-in-Charge. Make - Cat part No BCLSB 10WH of Bajaj / LCTL-9-CDL of Crompton / LUMILINEBS9 WLED 865 SPCWH of Havells
Supply and fixing Sleek Pressure die cast aluminium housing/body, heat resistant clear glass, LED lens for wide beam, energy saving, IP65/66 protection, not less than 5700K, better optics for uniform distribution street/Roadway luminaire with high power LED 25 watt complete fitting with driver, LED strip and all other accessories etc, suitable for 40/32mm OD entry for direct mounting on pipe bracket, fixing on poles/along wall with and including brackets made out of GI tubing light grade 40mm dia, 2 metre long bent to shape at 120 degree angle at half metre from bottom (as per sample), fixing with MS clamp (02 Nos) and nut bolts, including before fixing applying two coats of aluminium paint on bracket and clamp over a coat of red oxide primer, including making electric connection with using twin core copper cable of suitable size complete all as specified and as directed by Engineer-in-charge. Make - Cat part No LSTS-25-CDL of Crompton/ BRLEP 25W LED WH of Bajaj / ENDURA PEARL SL25W LED757SASYTOPC of Havells / HLSLD-09-25CWL-R of Halonix
Supply and fixing in replacement recessed LED ceiling tile with wide light window for maximized glare free output suitable for 600x600mm and ceiling cutout 595x595mm modular grid/POP ceiling complete fitting with separate electronic driver and high brightness LEDs 36 W (100 lumens per watt), not less than 5700K including connecting electric connection, complete all as specified and as directed by Engineer-in-Charge. Make : Cat part No. LCTLRN-36-F0-CDL of Crompton / BZRSQL 36W GZ1 CW of Bajaj / PCGLLL 36 57 of Polycab / VENUSNEOHE2X2PLR18-42WLED857MOD of Havells
Supply and laying XLPE LT Cable of size 16 Sqmm, 2 core, 1100 Volt grade heavy duty with XLPE insulated, stranded aluminium conductor served with an inner sheathening of PVC tape armoured with Galvanized steel strip or wire and over all PVC Sheathed stranded conductor conforming to IS- 7098 (Part-I) with latest amendments laid in trenches/fixed to wall/pole/laid in floor including necessary connections and suitable size of thimbling complete all as specified and as directed by Engineer-in-charge. Note :- (i) Excavation, earth work, sand cushioning, brick protection, cutting of road and pipe shall be measured & paid separately under appropriate item of this Schedule.)
Supply and filling Local sand cushioning , with dry and clean sand, over and under the under ground cables in trenches, ducts for cable protection including consolidation, 80mm thick to the authorized width as per SSR–Part-I before laying of cable and 150mm thick after laying of cable complete all as specified and as directed by Engineer-in-Charge. (Note :- For measurement purpose puned thickness shall be measured and paid i.e 18cm.)
Supply and laying Best quality, locally available, sub class ‘B’ bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing/laying GI tubing, light grade, 25 mm bore for protection of cable or earthing lead wire under hardstanding/fixed along poles/wall, laid in in trenches etc complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing exhaust fan 300 mm sweep (BEE, 5 star rated) with louvres, 230V, single phase AC supply, hanging on wall with 4 Nos steel fastners 10mm dia 100mm long and making good the disturbed surface as per existing surfaces, and connection to fan with suitable flexible twin core round copper wire complete all as specified and directed by Engineer-in-Charge. Make - Usha / Bajaj / Khaitan / Orient / Crompton / Polar
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including earth continuity GI wire 4 mm (upto test point from earth plate i.e. 7.5m min) by means of GI bolts/nuts/washers and including protected by 15mm dia GI light grade protection pipe from earth plate to test point, including making of test point made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos- 8mm dia 25mm long hex head screw. Earth plate shall be surrounded by packed layer of char coal/coke & salt all around bottom and top with alternative layer. 20mm GI light grade pipe for watering (should be 10cm above GL) and including socket, plug, funnel, wire mesh, CI cover 10mm thick hanged to CFI frame, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate), including necessary form work, excavation and earth work in any type of soil , returning filling and disposal of surplus soil to a distance not exceeding 50m, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ
K L JINDAL AND CO.
SHARDA ENTERPRIES
M/s PANKAJ KUMAR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .