Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
13 Jan 2025, 6:00 pmClosed
SUPERINTENDING ENGINEER Oand MCIV BTPS 5X200 MW Ob
Office of Superintending Engineer BTPS Obra
Reinsulation in classF and rewinding of stators of 6600V HT Motors of 5x200 MW Units BTPS Obra
2025_RVUNL_989635_1
NOBR6000007055
Open Tender
Electrical Works
Lump-sum
EMDIII BTPS OBRA
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,180
Dy Chief Account Officer CFA andBO BTPS Obra
₹40,000
24 Jan 2025
3 Jan 2025
15 Jan 2025
3 Jan 2025
13 Jan 2025
3 Jan 2025
3 Jan 2025 - 13 Jan 2025
Complete rewinding of 6.6 KV B.F.P. Motor Stator (3500KW, 54 Coils)with fresh copper and class 'F' insulation & replacement of all RTDs
Complete reinsulation of 6.6 KV B.F.P. Motor Stator (3500KW, 54 Coils)with class-F insulation and also replacement of damaged coils & replacement of all RTDs
Stator core re-staggering
Rate of new coil with fresh copper and class-F insulation for one coil only
Complete rewinding of 6.6 KV I.D. Fan Motor Stator (1700KW, 72 Coils)with fresh copper and class 'F' insulation & replacement of all RTDs
Complete reinsulation of 6.6 KV I.D. Fan Motor Stator (1700KW, 72 Coils)with class-F insulation and also replacement of damaged coils & replacement of all RTDs
Stator core re-staggering
Rate of new coil with fresh copper and class-F insulation for one coil only
Complete rewinding of 6.6 KV P.A. Fan Motor Stator (1250KW, 72 Coils)with fresh copper and class 'F' insulation & replacement of all RTD
Complete reinsulation of 6.6 KV P.A. Fan Motor Stator (1250KW, 72 Coils)with class-F insulation and also replacement of damaged coils & replacement of all RTDs
Stator core re-staggering
Rate of new coil with fresh copper and class-F insulation for one coil only
Complete rewinding of 6.6 KV F.D. Fan Motor Stator (630KW, 90 Coils) with fresh copper and class 'F' insulation & replacement of all RTDs
Complete reinsulationof 6.6 KV F.D. Fan Motor Stator (630KW, 90 Coils) with class-F insulation and also replacement of damaged coils & replacement of all RTDs
Stator core re-staggering
Rate of new coil with fresh copper and class-F insulation for one coil only
Complete rewinding of 6.6 KV C.W. Pump Motor Stator (450KW, 108 Coils)with fresh copper and class 'F' insulation & replacement of all RTDs
Complete reinsulation6.6 KV C.W. Pump Motor Stator (450KW, 108 Coils) with class-F insulation and also replacement of damaged coils & replacement of all RTDs
Stator core re-staggering
Rate of new coil with fresh copper and class-F insulation for one coil only
Complete rewinding of 6.6 KV Bowl Mill Motor Stator (340KW, 72 Coils) with fresh copper and class 'F' insulation & replacement of all RTD
Complete reinsulation of 6.6 KV Bowl Mill Motor Stator (340KW, 72 Coils)with class-F insulation and also replacement of damaged coils & replacement of all RTDs
Stator core re-staggering
Rate of new coil with fresh copper and class-F insulation for one coil only
Complete rewinding of 6.6 KV H.P. Ash Water Pump Motor Stator (262KW, 60 Coils)with fresh copper and class 'F' insulation & replacement of all RTDs
Complete reinsulation 6.6 KV H.P. Ash Water Pump Motor Stator (262KW, 60 Coils)with class-F insulation and also replacement of damaged coils & replacement of all RTDs
Stator core re-staggering
Rate of new coil with fresh copper and class-F insulation for one coil only
Complete rewinding of 6.6 KV C.E.P. Motor Stator (220KW, 48 Coils) with fresh copper and class 'F' insulation & replacement of all RTDs
Complete reinsulation of 6.6 KV C.E.P. Motor Stator (220KW, 48 Coils) with class-F insulation and also replacement of damaged coils & replacement of all RTDs
Stator core re-staggering
Rate of new coil with fresh copper and class-F insulation for one coil only
Complete rewinding of 6.6 KV S.O.P. Motor Stator (200KW, 90 Coils)with fresh copper and class 'F' insulation & replacement of all RTDs
Complete reinsulation of 6.6 KV S.O.P. Motor Stator (200KW, 90 Coils)with class-F insulation and also replacement of damaged coils & replacement of all RTDs
Stator core re-staggering
Rate of new coil with fresh copper and class-F insulation for one coil only
Complete rewinding of 6.6 KV E.F.P./H.P. Fire Pump Motor Stator (168KW, 48 Coils)with fresh copper and class 'F' insulation & replacement of all RTDs
Complete reinsulationof 6.6 KV E.F.P./H.P. Fire Pump Motor Stator (168KW, 48 Coils) with class-F insulation and also replacement of damaged coils & replacement of all RTDs
Stator core re-staggering
Rate of new coil with fresh copper and class-F insulation for one coil only
OM ELECTRICALS POWER PVT. LTD. (BID ID -4847234)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .