Loading…
Loading…
Tender Value
₹41.0 L
EMD Value
₹82,100
Closing Date
7 Sept 2026, 11:00 am
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
TENDER
13 conditions · 2 needing a document upload
No Financial credentials are required for tenders having advertised value up to Rs.50 lakhs.
No Technical credentials are required for tenders having advertised value up to Rs.50 lakhs.
27 conditions · 3 needing a document upload
Uploading of Scanned copy of Statement of Bank details, PAN & GST.
Compliance with Public Procurement (Preference to Make inIndia) Policy: This tender complies with Public Procurement(Preference to Make in India), Order 2017-Revision dated19.07.2024 of Department of Promotion of Industry and InternalTrade, Ministry of Commerce and Industry, Govt. of India (hereinreferred to as PP-PIM), circulated vide Ministry of Railways(Railway Board)'s letter No.2020/RS(G)/779/2/Pt.1 (E3322671)dated 20.08.2024, and all its amendments. Only Class-I localsuppliers (as defined in PP-PIM) shall be eligible to bid for list ofitems specified in Ministry of Railways (Railway Board)'s letterno.2025/RS(G)/779/3 (E3488356) dated 02.05.2025. For otheritems, only Class-I and Class-II local suppliers are eligible to bid.At the time of bidding, each bidder is required to indicatepercentage of local content (as defined in PP- PIM) and provideself-certification that the item offered meets the local contentrequirement for "Class-I local supplier"/"Class-II local supplier",as the case may be. If this self-certification is not submitted, thebid will be summarily rejected. For contracts above Rs.10 crores,the provisions of Para 9(c) of PP-PIM shall be additionallyapplicable. For the purposes of this NIT, the "local content" (asdefined in PP-PIM) requirement to categorize a supplier as"Class-I local supplier" is minimum 50% and for "Class-II localsupplier" is minimum 20%. Also, the Margin of PurchasePreference (as defined in PP-PIM) is 20%. The procedure forpreference to Make in India shall be as specified in PP-PIM.Uploading of self-certificate for meeting the local contentrequirement for "Class-I local supplier"/"Class-II local supplier",as the case may be (proforma attached). Non- submission of thiscertificate will lead to summary rejection of bid. ( Click here to download Format)
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Setting up of quick coach watering system with allied facilities at SBHR station.
Y-E-29-2026-27-70~SWR
Y-E-29-2026-27-70
Open
Works - General
120 Days
Dharwad, Karnataka
₹0
₹82,100
14 Aug 2026
14 Aug 2026
24 Aug 2026
95 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 41,02,754.03 | ||
| — | 50.00 | — | — | ||
| Platform surface/concrete/Road cutting for excavation of cable trench 300 mm wide x 300 deep, re-fitting of soil and re-plastering of excavated trench with cement on the PF's to bring original shape. | — | — | — | 31,292 | |
| — | 50.00 | — | — | ||
| Excavation of cable trench below the Rail track/road crossing 450 mm wide and 1000 mm. deep in all types of soil and refilling the released ballast. | — | — | — | 13,180.5 | |
| — | 800.00 | — | — | ||
| Excavation of cable trench, 450 mm. wide and 1000 mm. deep in all types of soil and refilling the cable trench to original shape by excavated soil free from unwanted materials. | — | — | — | 1,37,648 | |
| — | 200.00 | — | — | ||
| Excavation of Trenchless duct using horizontal drilling in all types of soil for laying of LTUG/HTUG cable across the track/road. | — | — | — | 3,17,470 | |
| — | 800.00 | — | — | ||
| Supply of HDPE Pipe of dia 75 mm grade PE-100 with pressure of PN 6 for safety of cables. | — | — | — | 1,12,000 | |
| — | 800.00 | — | — | ||
| Laying of HDPE Pipe of dia 75 mm grade PE-100 with pressure of PN 6 for safety of cables and all the ends should be sealing with bituminous compound. | — | — | — | 11,592 | |
| — | 600.00 | — | — | ||
| Supply of HDPE pipe of dia 110 mm grade PE-100 with pressure of PN 8 for safety of cables. | — | — | — | 2,41,200 | |
| — | 600.00 | — | — | ||
| Laying of HDPE Pipe of dia 110 mm grade PE-100 with pressure of PN 8 for safety of cables and all the ends should be sealing with bituminous compound. | — | — | — | 12,768 | |
| — | 500.00 | — | — | ||
| Laying of 4x16 - 35 Sq mm LTUG cable with aluminium conductor including end terminations at both ends. This work includes Extension of power supply from the nearest power supply source in the excavated cable trench/in trough/on building walls/sheds/shelters etc. | — | — | — | 4,815 | |
| — | 500.00 | — | — | ||
| Laying of 4 x 50-240 Sq mm LTUG cable with aluminium conductor including end terminations at both ends. This work includes Extension of power supply from the nearest power supply source in the excavated cable trench/in trough/on building walls/sheds/shelters etc. | — | — | — | 10,870 | |
| — | 500.00 | — | — | ||
| Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of above 185 sq. mm and upto 400 sq. mm size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. | — | — | — | 1,82,000 | |
| — | 100.00 | — | — | ||
| Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) size on wall surface as required. | — | — | — | 27,100 | |
| — | 12.00 | — | — | ||
| Supply and Fixing of GI pipe 'B' class of dia 50 mm. for cable rising & protection including clamping, fixing arrangements and sealing with bituminous compound. | — | — | — | 10,702.44 | |
| — | 1.00 | — | — | ||
| Design, Supply, fixing and commissioning of 12 Way DP Double Door Distribution Board with following switchgears (All 'C' Series) incomer 40 A TP RCBO sensitivity 30 mA-1 Nos. and outgoing SP MCB 6-32A 10 Ka - 10 Nos. with required suitable hardware and internal wiring complete. | — | — | — | 10,127.63 | |
| — | 6.00 | — | — | ||
| L.T. Earthing arrangements for hard soil using 50 mm C-Class GI Pipe- 2.7 Mtr length, soil treatment by spreading of 25 kgs each of salt and charcoal, duly painting earth pit with black paint and stenciling of earth resistance value with date, including supply and laying of 6 SWG G.I. wire and other hardware to connect equipment at site complete. | — | — | — | 32,600.58 | |
| — | 10.00 | — | — | ||
| Provision of cable route indicator with supply of RCC cable marker as per specification. The engraved lettering of the cable marker shall be, 33 KV / 11 KV / LT CABLE, erection shall be digging of pit to a depth of 800mm of size 300mm x 300mm and casting of concrete foundation of size 300mm x 300mm x 300mm with RCC cable marker casted as single unit and marker shall be placed vertically with lettering portion above GL (remaining below GL) and refilling the pit, as per the instruction of Railway representative at site. | — | — | — | 5,432.7 | |
| — | 1.00 | — | — | ||
| Supply and commissioning of Pump set of 3 pump each having 60 HP Flow 320 m3/hr, Head 35m, centrifugal/in-line vertical pump with Mechanical seal, Electric Motor Motor & Pump should be including Base Plate coupling, coupling Guard and Set of Foundation Bolts. Insulation Class H and efficiency of IE3 or higher as per latest CAMTECH manual complete. | — | — | — | 11,06,798.7 | |
| — | 1.00 | — | — | ||
| Provision of suitable Civil Foundation of Pump & Common Skid Mounting for 3 no of Pumps 60 HP capacity and as instructed by Engineer in-charge of the work. | — | — | — | 1,77,000 | |
| — | 1.00 | — | — | ||
| Design, Manufacture, supply, erection, testing & commissioning of free standing floor mounted, PLC based control panel suitable for 3 Nos. Pumps (minimum 45KW) panel made up of 14 SWG CRCA (Cold Rolled Carbon Annealed) sheet after seven tank process and painting with EPOXY powder coating suitable for 3 Phase, 4 wire 415 Volts, AC supply system for comprising with:(i) Incoming 400 A with CTR 400/5 A 4 P, 35 KA B/C, Microprocessor based Adjustable MCCB = 01 No. (ii) Outgoing 125 A with CTR 125/5 A4 P 35 KA B/C, Microprocessor based Adjustable MCCB= 03 No. (iii) Outgoing 32 A 4 P 10 KA B/C, B type MCB= 02 No.(iv) Heavy duty Variable Frequency Drive (VFD) suitable for minimum 45 KW Pump=3 Nos.(v) 15 KVAR Heavy Duty Capacitor=3 No.(vi) Set /Individual Electronic Motor Protection Relay for provision of adequate protection against single phasing, under voltage, over-voltage, earth leakage, overload, dry run protection etc.=3 set(vii) Multifunction Meters for measuring (Parameters: V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Run hours, On hours, Phase angle, Interrupts, THD, Events (High-Low), Neutral Current, K Factor) along with suitable ratios CTs(Current transformer) = each incoming & outgoing =4 set The panel shall be complete with 400A Copper Bus Bars for Phases and 200A for Neutral as per drawing approved by Railways. The panel shall have LED indication light for each incoming & Outgoing shall be available for phase indication, voltage, current, ON/OFF. | — | — | — | 7,17,106 | |
| — | 500.00 | — | — | ||
| Supply and commissioning of copper shielded cable of 6 core 1.5 sq.mm for flow meter valve & butter fly valve wiring. | — | — | — | 34,750 | |
| — | 1.00 | — | — | ||
| Supply and commissioning of SCADA & COMMUNICATION, DATA ANNALZER, With LED MOINTOR of 32 " or higher With P.C. and Printer for Report Generation including UPS. | — | — | — | 3,30,000 | |
| — | 1.00 | — | — | ||
| Supply, installation, testing & commissioning of 1.5 Ton AC, 5 star BEE rating inverter type AC, high wall split ac, Eco-friendly refrigerant with remote, outdoor unit Mounting stand with copper coils and minimum 3 meter / as per requirement length of copper Pipe and suitable connecting electrical cable for installation and commissioning. As per IS 1391 latest part 2 for room air conditioner and as per technical specification. Warranty of the machine 5 year and the warranty of the compressor 10 years minimum along with the installation and commissioning of split AC. | — | — | — | 54,700.08 | |
| — | 2.00 | — | — | ||
| Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (with charcoal/ coke and salt ) as required. | — | — | — | 16,702 | |
| — | 2.00 | — | — | ||
| Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (with charcoal/ coke and salt ) as required. | — | — | — | 30,008 | |
| — | 30.00 | — | — | ||
| DG Earthing-Connections with 40x6mm copper strip in 50mm dia G.I. pipe class-B, 300 mm deep in ground/recessing in floor from earth electrode strip to neutral of transformer/alternator as per drawing and technical specification. including supply of material. | — | — | — | 24,540 | |
| — | 30.00 | — | — | ||
| DG Earthing-Connection with 40x10mm GI strip 300mm deep in ground/recessing in floor/clamping in Trenches of substation by grouting clamps manufactured with MS sheet 14 SWG, from earth electrode strip to HT panel/LT panel/AMF panel/Transformer/DG set etc. as per approved drawing and technical specification including supply of material. | — | — | — | 4,050 | |
| — | 60.00 | — | — | ||
| Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. | — | — | — | 17,220 | |
| — | 30.00 | — | — | ||
| Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. | — | — | — | 2,520 | |
| — | 30.00 | — | — | ||
| Wiring for circuit/ sub main wiring along with earth wire with the 2 X 6 sq. mm + 1 X 6 sq. mm earth wire sizes of FRLSH / HFFR PVC insulated copper conductor, single core cable in surface / concealed medium class PVC conduit / casing & capping as required at site. | — | — | — | 14,460 | |
| — | 50.00 | — | — | ||
| Wiring for circuit/ sub main wiring along with earth wire with the 2 X 4 sq. mm + 1 X 4 sq. mm earth wire sizes of FRLSH / HFFR PVC insulated copper conductor, single core cable in surface / concealed medium class PVC conduit / casing & capping as required at site. | — | — | — | 18,650 | |
| — | 100.00 | — | — | ||
| Wiring for circuit/ sub main wiring along with earth wire with the 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire sizes of FRLSH / HFFR PVC insulated copper conductor, single core cable in surface / concealed medium class PVC conduit / casing & capping as required at site. | — | — | — | 31,100 | |
| — | 20.00 | — | — | ||
| Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLSH / HFFR PVC insulated copper conductor single core cable in surface / Concealed medium class PVC conduit / Casing & capping, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLSH / HFFR PVC insulated copper conductor single core cable etc. as required.(Group - A). | — | — | — | 23,780 | |
| — | 6.00 | — | — | ||
| Supplying and fixing suitable size GI / PVC box with modular plate and cover in front on surface / recess / concealed, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. / casing & capping as per site requirement. | — | — | — | 3,270 | |
| — | 4.00 | — | — | ||
| Supplying and fixing suitable size GI / PVC box with modular plate and cover in front on surface / recess / concealed, including providing and fixing 6 pin 15/16/20 A modular socket outlet and 15/16/20 A modular switch, connections etc. / casing & capping as per site requirement. | — | — | — | 2,636 | |
| — | 8.00 | — | — | ||
| Supply, fixing, testing and commissioning of 18 - 22 watt 6500 k batten 4 feet approximate length LED lighting fixture as per specification SWR/LED LIGHT FITTING (Indoor/outdoor) /001-2016 effective from 18.04.2016 or latest. Including all other required accessories complete. | — | — | — | 5,448 | |
| — | 2.00 | — | — | ||
| Supply, fixing, testing and commissioning of 10 watt, 2 feet approximate length, 6500 k LED batten fixtures Including all other required accessories complete. | — | — | — | 356.48 | |
| — | 2.00 | — | — | ||
| Supply, Installation, Testing and commissioning of ceiling fan with Brush Less Direct Current (BLDC) motor ceiling fans 26 W 5 star rated with remote 1200 mm size as per specifications. | — | — | — | 5,764 | |
| — | 2.00 | — | — | ||
| Supply, fixing and commissioning of 200 mm size BLDC Ventilating fan complete. | — | — | — | 3,503.22 | |
| — | 4.00 | — | — | ||
| Supply of 45 Watt LED street lights, as per specification SWR/LED LIGHT FITTING (Indoor/outdoor)/001-2016 effective from 18.04.2016 r latest. | — | — | — | 7,813.64 | |
| — | 4.00 | — | — | ||
| Freight, fixing, testing and commissioning of LED street lights along with suitable size pipe bracket and hardware complete. | — | — | — | 480.88 | |
| — | 2.00 | — | — | ||
| Supply and provision of submersible Horizontal mono block pump to be installed in sump suitable for 415 V three phase supply 15 HP. Similar to Model- Kirloskar KDS-1575+ or equivalent specifications. | — | — | — | 96,887.24 | |
| — | 2.00 | — | — | ||
| Supply, installation, testing and commissioning of control panel for 15 HP mono-block submersible pump. | — | — | — | 34,246.94 | |
| — | 1.00 | — | — | ||
| Supply and provision of Three Phase Submersible Pump Set 5.5 kilo watt / 7.5 HP as per Detailed Description/Specification as per Product # 1 of GeM Contract No. GEMC- 511687794929829 dt.09/01/2025). | — | — | — | 50,107.8 | |
| — | 1.00 | — | — | ||
| Supply and provision of Micro controller based Digital type Direct On Line starter panel suitable for 5HP to 7.5HP, 3Phase submersible pump consists of 16 A Contactor - 1No, Digital voltmeter and ammeter, Dry running protection, Single Phasing Preventer and over load protection, ON/OFF push buttons, Phase indication lamps - 3Nos. | — | — | — | 7,026.8 | |
| — | 150.00 | — | — | ||
| Supply and provision of heavy duty uPVC column pipe coupler of 50 mm dia, pressure 27 kg/cm2 with collars and other required suitable accessories complete. | — | — | — | 63,900 | |
| — | 200.00 | — | — | ||
| Supplying & fixing PVC insulated PVC sheathed copper conductor submersible 3 Core 6.0 Sq mm Flat Cable, ISI Marked in existing metal/ HDPE / PVC/ pipe/ in bore well/ in sump including fixing the cable to GI/HDPE pipe with suitable cable tags of following sizes etc. complete as required. | — | — | — | 53,200 | |
| — | 30.00 | — | — | ||
| Supply, erection, testing & commissioning of Steel such as MS Channel, Flat, Angles with nuts & bolts washer of suitable size for various work of any item. | — | — | — | 3,929.4 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Tender Booklet
ATTACHMENT
Advance Correction Slips to GCC
ATTACHMENT
GCCApril-2022.pdf
ATTACHMENT
JPOintenderdocumnets.pdf
ATTACHMENT
AdvanceCorrectionSlips1-11toGCC-2022.pdf
ATTACHMENT
TB-SBHRsettingupofQuickcoachwatering_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].