Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹91.7 LAccepted-AOC HOUSE NO 44 MASTER COLONY SATROD KHAS HISAR HARYANA 125044 | HISAR | HISAR | HARYANA | 125044 | ₹91.7 L Quoted ₹92.0 L | L-1 | Accepted-AOC Being L-1 |
| 2 | L-2₹92.7 LRejected-AOC FLAT NO 4 C GH 39 MANSA DEVI COMPLEX SECTOR 05 PANCHKULA 134 109 HRY | PANCHKULA | PANCHKULA | HARYANA | 134109 | ₹92.7 L | L-2 | Rejected-AOC Other than L-1 |
| 3 | L-3₹94.2 LRejected-AOC 112 SHIV NAGAR II MURALIPURA SIKAR ROAD JAIPUR RJ | JAIPUR | RAJASTHAN | 302001 | ₹94.2 L | L-3 | Rejected-AOC Other than L-1 |
| 4 | L-4₹1.0 CrRejected-AOC 795 AZAD NAGAR ROORKEE HARIDWAR PIN CODE 247667 | ROORKEE | HARIDWAR | UTTARAKHAND | 247667 | ₹1.0 Cr | L-4 | Rejected-AOC Other than L-1 |
| 5 | L-5₹1.2 CrRejected-AOC 303 GHS 88 SECTOR 20 PANCHKULA 134113 HARYANA | PANCHKULA | HARYANA | 134113 | ₹1.2 Cr | L-5 | Rejected-AOC Other than L-1 |
| Sl No | Description | Qty | Unit | R D Bansal L5 | m/s nemichand contractor L3 | m/s AR Construction co L1 | Babu Ram Sud and Sons L2 | M/S KOHLI CONSTRUCTION L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for Roughening surfaces of old concrete floor by pricking, sweeping clean and washing down with water to remove dust etc. complete all as specified and as directed by Engineer-in-Charge. | 600 | SQUARE METRE | 35 ₹21,000 | 10 ₹6,000 | 10 ₹6,000 | 20 ₹12,000 | 5 ₹3,000 |
| 2.00 | M&L for 40 mm thick PCC 1:2:4, type B-1 (using 20 mm graded stone aggegates) as in roof padding, complete all as specified and as directed by Engineer-in-Charge. | 600 | SQUARE METRE | 275 ₹1.6 L | 225 ₹1.4 L | 250 ₹1.5 L | 297 ₹1.8 L | 300 ₹1.8 L |
| 3.00 | M&L for rendering 10 mm thick in Cement Mortar 1:3 mixed with liquid water proofing compound as per manufacturer's instructions on concrete/ brick surfaces, finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge.
Note: WPC shall be measured and paid separately. | 600 | SQUARE METRE | 275 ₹1.6 L | 140 ₹84,000 | 150 ₹90,000 | 297 ₹1.8 L | 300 ₹1.8 L |
| 4.00 | Supply only integral water proofing compound, ISI marked, complete all as specified and as directed. | 330 | KILOGRAM | 75 ₹24,750 | 40 ₹13,200 | 80 ₹26,400 | 45 ₹14,850 | 75 ₹24,750 |
| 5.00 | M&L for APP based polymeric membrane minimum weight 3.6 kg/sqm and minimum 3 mm thick, reinforced with polyster non woven fabric (weight not less than 150 gm/sqm) laid over and including priming surfaces with glass fibre base (except felt) and laying APP membrane on Primed surface by torch application and sealing all joints and overlapping min 10 cm, including preparation of top surfaces of concrete complete all as specified and as directed by Engineer-in-Charge. | 600 | SQUARE METRE | 375 ₹2.3 L | 550 ₹3.3 L | 430 ₹2.6 L | 360 ₹2.2 L | 1,500 ₹9 L |
| 6.00 | M&L for preparation of new surface of roof treatment etc. and applying two coats of aluminium paint complete all as specified and as directed by Engineer-in-Charge. | 600 | SQUARE METRE | 90 ₹54,000 | 70 ₹42,000 | 50 ₹30,000 | 60 ₹36,000 | 40 ₹24,000 |
| 7.00 | Excavating in post holes (or similar holes) in hard/ dense soil, each hole not exceeding 0.5 cubic metre, getting out and removing excavated material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point, complete all as specified and as directed by Engineer-in-Charge. | 16 | EACH | 75 ₹1,200 | 300 ₹4,800 | 200 ₹3,200 | 75 ₹1,200 | 70 ₹1,120 |
| 8.00 | M&L for Plain Cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete, complete all as specified and as directed by Engineer-in-Charge. | 3.5 | CUBIC METRE | 5,500 ₹19,250 | 5,000 ₹17,500 | 3,200 ₹11,200 | 4,200 ₹14,700 | 4,500 ₹15,750 |
| 9.00 | S&F of Rolled mild steel tubular sections as in main and cross beams, hip and jack rafters; purlins, posts where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates, Fe-410-W (Gde-Fe-250) quality- B complete all as specified and as diected by Engineer-in-Charge. | 3,070 | KILOGRAM | 140 ₹4.3 L | 100 ₹3.1 L | 98 ₹3.0 L | 95 ₹2.9 L | 92 ₹2.8 L |
| 10.00 | S&F Mild Steel Works as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe-410-W (Gde-E-250) quality-B complete all as specified and as directed by Engineer-in-Charge. | 1,820 | KILOGRAM | 130 ₹2.4 L | 110 ₹2.0 L | 98 ₹1.8 L | 95 ₹1.7 L | 92 ₹1.7 L |
Updated dates
Tender Value
₹1.1 Cr
EMD Value
₹1.9 L
Closing Date
28 Jan 2026, 6:00 pmClosed
CWE Chandimandir
HQ CWE Chandimandir, PIN-134107
CWE/KAS-120/2025-26 ADDITION/ ALTERATION and SPECIAL REPAIR TO CERTAIN BUILDINGS AT 14 GORKHA TRAINING CENTRE SUBATHU UNDER GE KASAULI
2025_MES_745887_1
CWE/KAS-120/2025-26
Open Tender
Civil Works
270 days
GE Kasauli
Class B, Cate a(i)
9 documents required · 9 mandatory
₹1,000
GE Kasauli
₹1.9 L
29 Apr 2026
23 Dec 2025
31 Jan 2026
24 Dec 2025
28 Jan 2026
14 Jan 2026
24 Dec 2025 - 30 Dec 2025
M&L for Roughening surfaces of old concrete floor by pricking, sweeping clean and washing down with water to remove dust etc. complete all as specified and as directed by Engineer-in-Charge.
M&L for 40 mm thick PCC 1:2:4, type B-1 (using 20 mm graded stone aggegates) as in roof padding, complete all as specified and as directed by Engineer-in-Charge.
M&L for rendering 10 mm thick in Cement Mortar 1:3 mixed with liquid water proofing compound as per manufacturer's instructions on concrete/ brick surfaces, finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge. Note: WPC shall be measured and paid separately.
Supply only integral water proofing compound, ISI marked, complete all as specified and as directed.
M&L for APP based polymeric membrane minimum weight 3.6 kg/sqm and minimum 3 mm thick, reinforced with polyster non woven fabric (weight not less than 150 gm/sqm) laid over and including priming surfaces with glass fibre base (except felt) and laying APP membrane on Primed surface by torch application and sealing all joints and overlapping min 10 cm, including preparation of top surfaces of concrete complete all as specified and as directed by Engineer-in-Charge.
M&L for preparation of new surface of roof treatment etc. and applying two coats of aluminium paint complete all as specified and as directed by Engineer-in-Charge.
Excavating in post holes (or similar holes) in hard/ dense soil, each hole not exceeding 0.5 cubic metre, getting out and removing excavated material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point, complete all as specified and as directed by Engineer-in-Charge.
M&L for Plain Cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete, complete all as specified and as directed by Engineer-in-Charge.
S&F of Rolled mild steel tubular sections as in main and cross beams, hip and jack rafters; purlins, posts where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates, Fe-410-W (Gde-Fe-250) quality- B complete all as specified and as diected by Engineer-in-Charge.
S&F Mild Steel Works as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe-410-W (Gde-E-250) quality-B complete all as specified and as directed by Engineer-in-Charge.
S&F MS Plates (plain or chequered) in channels, angles, square cut or notched (ordinary and counter sunk) forming holes, with rivetted, bolted or welded attachment, Fe-410-W (Gde-Fe-250) quality- B complete all as specified and as directed by Engineer-in-Charge.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet, 0.50 mm thick, of any colour (approved by GE) having tensile strength of 550 Mpa as in roof covering/ cladding to wall, sunshades etc., fixed all as per manufacturer's instructions and fixed with self tapping steel screws of length not less than 50 mm complete all as specified and as directed by Engineer-in-Charge.
S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour (or decorated design cutting) having tensile strength of 550 Mpa as in roof covering/ cladding to wall, ridges, flashing, eaves board valley gutter of any shape etc, cut to designed shape (Jhhallar) as directed at site fixed all as per manufacturer's instructions and fixed with self tapping steel screws of length not less than 50 mm complete all as specified and as directed by Engineer-in-Charge.
S&F Fibre glass reinforced translucent corrugated sheeting, 2 mm thick with two corrugations side lap fixed with coach screw and washer in roof, wall etc., fixed all as per manufacturer's instructions and fixed with self tapping steel screws of length not less than 50 mm complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for mild steel work as in hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.,) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed by Engineer-in-Charge.
Demolition of cement concrete (un-reinforced) in ground floor and pavings not exceeding 15 cm thickness (below or above GL) as in plinth protection/ path/ Hard standing/ floor etc. including removal of debris outside MD land complete all as specified and as directed by Engineer-in-Charge.
M&L for Roughening surfaces of old concrete floor by pricking, sweeping clean and washing down with water to remove dust etc., and M&L for brushing neat cement slurry with 3 kg of cement per sqm complete all as specified and as directed by Engineer-in-Charge.
M&L for Machine cut kota stone slab flooring, 18-22 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including screed bed or beding layer of mortar 20 mm thick in cement mortar 1:4 for laying floor finishes to receiving the kota stone, complete all as specified and as directed by Engineer-in-Charge.
M&L for Kota stone slab 16-18 mm thick in riser of steps, skirting, dado and pillar etc., and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over and including cement screed and Screed bed or beding layer of mortar 10 mm thick in cement mortar 1:3 complete all as specified and as directed by Engineer-in-Charge.
M&L for Providing and injecting chemical emulsion for Post Constructional anti-termite treatment of soil under existing floors using emulsion @one litre per hole, 300 mm apart including drilling and plugging 12 mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed by Engineer-in-charge.
Demolition of stone slabs of any description in floors laid, bedded and pointed in any mortar complete all as specified and directed by Engineer-in-charge.
Supply and fixing factory made, rubber moulded machine pressed, coloured, chequered cement concrete tiles 300 mm x 300 mm x 25 mm thick, glossy finished (with grey cement and pigment), set, jointed and pointed in neat cement slurry with grey cement with pigment to match the colour of tiles, laid over and including 20 mm thick screed bed in cement mortar 1:6, including demolition of existing tiles complete all as specified and as directed by Engineer-in-Charge.
Material and labour for 75 mm thick plain cement concrete 1:3:6, type C-1 (using 20 mm graded crushed stone aggregate) as in plinth protection etc., finished even and smooth without using extra cement including necessary formwork, laid in alternate bays not exceeeding 2.50 metre in length, with construction joints of 6 mm thick, joint must be filled with bitumen mastic filling comprising of one part of heated bitumen 80/100 grade and three part of sand (by weight) complete all as specified and as directed by Engineer-in-charge.
Taking down existing plaster of any description on brick wall/ concrete surface/ parapet wall including racking out joints, hacking for key, scrubbing down with water etc, upto any height, complete all as specified and as directed by Engineer-in-Charge.
M&L for Rendering 15 mm thick in Cement Mortar 1:4 on fair faces of brick/ stone or concrete surfaces at any height including Pillars, cornices, chajjas (top & facia sides), sun shades etc., making sharp corners, finished even and smooth without using extra cement with water proofing compound (2% of cement content) (External surface) & curing complete all as specified and directed by Engineer-in-Charge. Note: 1. The unit rates quoted by the tenderer shall be deemed to include the cost of arrangement of necessary scaffolding, safety precaution and the like without any extra cost to the govt. 2. WPC will be measured and paid separately.
M&L for rendering 10 mm thick in cement mortar 1:6 on other than fair faces of brick/ stone or concrete surfaces, finished even and smooth without using extra cement (Internal surfaces) including proper curing complete all as specified and as directed.
M&L for rendering 5 mm thick in cement mortar 1:3 on ceiling surfaces, finished even and smooth without using extra cement complete all as specified and as directed.
M&L for preparation of new/ previously untreated surfaces of wall/ ceiling and applying 1 mm thick cement based wall care putty (applied in two layers) complete all as specified and as directed by Engineer-in-Charge.
M&L for applying two coats of oil bound distemper (OBD) over one coat of chalk white on wall surface of new/ previously untreated surfaces prepared under serial item No. 28.00 here-in-before complete all as specified and as directed by Engineer-in-Charge.
M&L for preparation of new/ previously untreated surfaces of wall and applying two coats of cement based paint including cornices, chajjas, sun shades etc. including curing the surfaces after application of cement based paint (tint as approved by GE) complete all as specified and as directed by Engineer-in-Charge.
M&L for applying two coat of oil bound distamper on ceiling surfaces of new/ previously untreated surfaces prepared under serial item no. 28.00 here-in-before complete all as specified.
M&L for preparation of old decorated surfaces of walls including cornices, chajjas, sun shades etc., and applying one coat of cement base paint with and including curing the same after application of cement base paint, complete all as specified and as directed by Engineer-in-Charge.
M&L for preparation of old decorated plastered surfaces of walls/ ceiling including scrapping down smoke, soot, and efflorescent salts and treatings oil and gresy spots, brooming down or steel wire brushing removing nails making good holes, cracks etc., using necessary filling of cement based wall care putty to obtain smooth regular/ even finish and applying one coat of oil bound distemper, complete all as specified and directed by Engineer-in-charge.
Taking down chowkhats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each with shutter(s) (without taking off shutters from the frame), including removing to store and making good the disturbed surface to match with existing surface complete all as specified and as directed by Engineer-in-Charge.
S&F factory made pressed steel frames, conforming to IS, having profile 125 mm x 60 mm for doors with one or more rebates made out of 1.25 mm thick mild steel sheet, including necessary fixing lugs, butt hinges, lock strike plate, etc., with and including filling hollow frame with plain cement concrete 1:3:6, type C-0 (using 12.5 mm graded crushed stone aggregates) complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing 2nd class hard wood Factory made plain, framed, panelled shutters, 35 mm thick (Hollock) with lock rail and panels of 9 mm thick commercial ply or 12 mm thick vaneered particle board with commercial veneered on both sides, including priming coat on shutter. The size of rail & style shall be as per IS 1003 part-1 kiln seasoned and chemically pressure treated complete all as specified and as directed by Engineer-in-Charge.
S&F 35 mm thick 2nd class hardwood glazed and Skelton shutter, open rebated and prepared to receive glass, gauge etc divided into squares (04 Nos) with plain chamfered or rounded mitred and rebated sash bars any number, edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc. Size of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and as directed by Engineer-in-Charge.
S&F Aluminium alloy, anodised sliding door bolts, 250 mm long with hasp and staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy, ISI marked, complete all as specified and as directed by Engineer-in-Charge.
S&F aluminium anodised barrel tower bolts of extruded section, 200 mm size, ISI marked, complete all as specified and as directed by Engineer-in-Charge.
S&F extruded aluminium alloy handles with plates, fabricated type, anodised 150 mm size, ISI marked, complete all as specified and as directed by Engineer-in-Charge.
S&F 300 mm, mild steel ordinary rat tail rod pattern springs including roller and roller plate complete, including welding on chowkat complete all as specified and as directed by Engineer-in-Charge.
S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperature 1.40 mm fixed with stainless steel wire staples/ beads complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of New Wooden surfaces of any description over 10 cm width and girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed by Engineer-in-charge.
M&L for preperation of new steel surfaces of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed by Engineer-in-Charge.
Material & labour for preparation of old wood or wood based surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint, complete all as specified and as directed.
Material & labour for preparation of old painted steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint, complete all as specified and as directed.
Excavation in trenches in soft/ disintegrated rock, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth; for foundation etc., or for shafts, wells, cesspits, manholes, pier holes, etc., not exceeding 10 sqm on plan and getting out complete all as specified and as directed by Engineer-in-Charge.
M&L for Plain Cement concrete 1:3:6 type C-2 (using 40 mm graded crushed stone aggregates) as in surface channel and drains, complete all as specified and as directed by Engineer-in-Charge.
M&L for Brickwork with sub-class ‘B’ bricks (old size bricks), straight or curved on plan to any radius in half brick thick walls, built in Cement Mortar 1:4, as in drains complete all as specified and as directed by Engineer-in-Charge.
Removal of excavated material (disintegrated rock) not exceeding 50 metre and at a level not exceeding 1.5 metre above the starting point and depositing where directed complete all as specified and as directed.
M&L for forming fair finished drain or drain channel 30 cm inner girth in cement concrete using extra cement including forms moulds mitred stopped ends etc., complete all as specified and as directed.
Material & Labour for Plain Cement concrete 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate) as in copings, bed plates, hold fasts, seismic and other similar bands, shelves and the like finished fair and even including necessary form work complete all as specified & as directed.
Taking down copper/ aluminium point wiring (light, fan, socket or power) complete, including fittings and fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions seperately) and making good distrubed surfaces of wall, floors, etc complete all as specified and as directed by Engineer-in-charge.
Material and labour for point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm, 1100 volts grade, two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm, 1100 volts grade for earth continuity conductor to common earth and connected to earth dolly drawn in and including concealed medium grade rigid non-metallic PVC conduit of suitable size/ bore with all fittings terminated on and including new modular GI metal sunken box of thickness not less than 1.2 mm and suitable size of frame, cover for mounting modular switch, socket and regulator fixed on surface flush with wall, for One light/ bell/ buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator, complete all as specified and as directed by Engineer-in-Charge.
All as per serial item 54.00 here-in-before but for socket outlet 3 pin 5 Amps on same board complete all as specified and as directed by Engineer-in-Charge.
All as per serial item No 54.00 here-in-before but for one socket outlet 3/ 5 pin, 5 Amps on independent board complete all as specified and as directed by Engineer-in-Charge.
All as per serial item 54.00 here-in-before but for One light point controlled by two, 2-way switches.
All as per Serial item No 54.00 here-in-before but for one socket outlet 3/5 pin, 15 Amps on independent board, size of cable 2.5 sqmm for phase, neutral & 2.5 sqmm as earth wire complete all as specified and as directed by Engineer-in-Charge.
All as per Serial item No 54.00 here-in-before but for one socket outlet 3/5 pin, 15 Amps on independent board, size of cable 4.0 sqmm for phase, neutral & 4.0 sqmm as earth wire complete all as specified and as directed by Engineer-in-Charge.
S&F modular switch, one way, 6 Amps, one module, 230 volts, single pole complete all as specified and as directed by Engineer-in-Charge.
S&F modular switch, two way, 6 Amps, one module, 230 volts, single pole complete all as specified and as directed by Engineer-in-Charge.
S&F modular switch, one way, 16 Amps, one module, 230 volts, single pole complete all as specified and as directed by Engineer-in-Charge.
S&F Modular socket outlet, 2 in 1, 3 pin 6 Amps, single pole, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
S&F Socket outlet mdoular type, multipurpose, 2/3 pin, single pole, two module, 6/16 Amps complete all as specified and as directed by Engineer-in-Charge.
S&F Modular fan step regulator, 120 watts, 2 module complete all as specified and as directed by Engineer-in-Charge.
S&F Ceiling rose 3 pin, 230 volts, PVC polycarbonate insulated body complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing DBOXx SRCD, 25 Amp, plug and play all-in-one device for providing protection from electric shock due to direct or indirect contact as well as provides protection from overload and short cicuit faults complete all as specified and as directed by Engineer-in-charge.
S&F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing LED Bulb, 12 Watt, ISI Marked complete all as specified and as directed by Engineer-in-Charge.
S&F Decorative wall light 9/12 watt LED, indoor type B-22 base, synthetic type materials, perfect ambiance for living/ bedroom suitable for all type lamp complete all as specified and directed by Engineer-in-charge.
S&F Inverter type LED tube light batten 4 feet, 1 x 18/20 watt, 230 volts inbuilt Lithium ion battery with charging time 8 to 10 Hours and back up time minimum 4 Hours complete including fitting fixed on wall/ ceiling and connecting up complete with flexible cable white of suitable size and making necessary connection complete all as specified and directed by Engineer-in-charge.
Supply and fixing LED lights fitting 1x 10 Watt, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by Engineer-in-Charge.
S&F LED 1x9W/ 1x10W bulkhead luminaires, decorative energy saving, new generation light wih opal diffuser including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing LED building security/ street light fitting 35 Watt, 230 V AC, outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/ 66 protection complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of Recess mounted LED, ultra slim 2' X 2', 36 watt, edge lit tile, extruded aluminium housing with full opal diffuser suitable for perfect lighting complete including cutting hole of required size in POP/ false ceiling and making good of disturbed surface complete all as specified and as directed by Engineer-in-Charge.
Taking down carefully copper/ aluminium sub main wiring complete, including existing batten/ conduit etc. removing materials deposited in store for keeping in safe custody and making good disturbed surfaces of walls, floors etc. complete all as specified and as directed by Engineer-in-charge.
Supply and fix Sub main wiring with 2 runs of 6.0 sqmm, single core, PVC insulated & unsheathed FRLS cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including non metallic PVC conduit (Concealed) of appropriate dia with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6.0 sqmm single core PVC insulated & unsheathed FRLS copper conductor as continous earth wire dolly and connecting to existing main switch board/ distribution board including Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 for concealed conduit wiring, etc., and making good, cutting not exceeding 10 cm girth complete all as specified and as directed by Engineer-in-charge.
Supply and fix Sub main wiring with 4 runs of 10.0 sqmm, single core, PVC insulated & unsheathed FRLS cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including non metallic PVC conduit (Concealed) of appropriate dia with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith 1 runs of 10.0 sqmm single core PVC insulated & unsheathed FRLS copper conductor as continous earth wire dolly and connecting to existing main switch board/ distribution board including Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 for concealed conduit wiring, etc., and making good, cutting not exceeding 10 cm girth complete all as specified and as directed by Engineer-in-charge.
Taking down carefully Old unserviceable DB of any size and capacity complete all as specified and as directed by Engineer-in-Charge.
S&F MCB Distribution Board, TPN, 4 Way, horizontal type, double door, flush mounting with provision for MCBs with 200 amps bus bar, neutral link, earth bar and din rail including connection and testing complete all as specified and as directed by Engineer-in-Charge.
S&F MCB Distribution Board, SPN, 8 Way, horizontal type, double door, flush mounting with provision for MCBs with 200 amps bus bar, neutral link, earth bar and din rail including connection and testing complete all as specified and as directed by Engineer-in-Charge.
S&F MCB Distribution Board, SPN, 12 Way, horizontal type, double door, flush mounting with provision for MCBs with 200 amps bus bar, neutral link, earth bar and din rail including connection and testing complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing MCB 40 Amp, TPN, 'C' series, 10 KA, 240 Volts complete all as specified and as directed by Engineer-in-charge.
Supply and fixing MCB 40 Amp, SPN, 'C' series, 10 KA, 240 Volts complete all as specified and as directed by Engineer-in-charge.
Supply and fixing MCB 6-32 Amp, SP, 'C' series, 10 KA, 240 Volts complete all as specified and as directed by Engineer-in-charge.
M&L for dismantling of ceiling Fan, cleaning the fan and fan blades, greasing including refixing the same complete all as specified and as directed by Engineer-in-charge.
S&F of fan controller as per existing model and make complete all as specified and as directed by Engineer-in-charge.
Supply and fixing exhaust fan, made of sturdy Engineering plastic complete with louvers shutters, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300 mm complete all as specified and as directed by engineer-in-charge.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in deep getting out in any type of soil for stay assembly/ laying of cable/ erection of poles etc complete all as specified and as directed by Engineer-in-charge.
Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed by Engineer-in-charge.
Removing of excavated material (soil) not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed by Engineer-in-charge.
Taking out carefully old/ unserviceable LT UG cable of any type/ size from trenches/ pole/ duct after disconnecting from Pole/ busbar including taking out all bricks/ HDPE pipe/ GI pipe used for cable protection and removing from site complete all as specified and as directed by Engineer-in-charge.
Supply, laying & testing of XLPE insulated, armoured, heavy duty LT cable, with stranded aluminium conductor, 1100 volts grade, of size 35 sqmm, 3.5 core, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete all as specified and directed by Engineer-in-Charge.
M&L for GI pipe, light grade, 50 mm bore, IS Marked for protection to cable, laid in trenches/ along the pole/ across road crossing/ passing through culvert complete all as specified and as directed by Engineer-in-Charge.
Supplying & fixing HDPE Double walled corrugated (DWC) duct pipe of 63 mm outer dia conforming to IS-14930 (Part-II) of approved colour with fittings for cable protection complete all as specified and as directed by Engineer-in-Charge.
M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick, buried directly in ground vertical to a depth not less than 2.25 metres deep below ground level with top edge of plate not less than 1.5 metre below normal gound level connected to galvanized iron strip of size 32 x 6 mm dia bolts, nuts, check nuts and washer of galvanized iron or steel all as shown in electrical plate No 3 connected to test point including testing complete including necessary excavation and earth work in any type of soil, PCC 1:3:6 type C-1 chamber, Cast Iron pit cover and frame, charcoal, salt, funnel, GI watering pipe 20 mm dia (medium grade), protection pipe 40 mm dia GI pipe (light grade) of length upto test point including taking down old earthing, any type complete all as directed by Engineer-in-Charge.
Note: The unit rate includes for protection pipe 40 mm dia and GI Strip from top of the earth plate upto 7.5 metre length.
S&F earth continuity conductor or main earthing lead 32 x 6 mm Galvanized Iron Strip; fixed to walls, on battens or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc as required complete all as specified and as directed by Engineer-in-Charge.
Supply, installation and testing outdoor type cubicle panel board bus bar box with MCCB suitable for 3 phase 4 wire, 50 Hz supply system factory fabricated made out of CRCA sheet steel of 3 mm thick for outer shell and 2 mm thick for inner shell with front openable door with locking arrangement complete with powder coat painting and suitable packing material for IP-54 degree of protection and including provision of 40 mm x 40 mm x 5 mm angle iron base frame of suitable size for mounting the panel board at a height of 450 mm above GL and grouted in PCC foundation, of suitable size for accommodating following switchgears complete:-
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.11 MB
Tenderdocuments120.pdf
Tender Documents • 0.80 MB
Additional120.pdf
Additional Documents • 0.54 MB
BOQ_835193.xls
BOQ • 0.47 MB
Download all tender documents and submit your bid