Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.5 LAccepted-AOC D 249 GREEN ESTATE A2Z BUILDER DEVELOPERS NH 58 ROORKEE ROAD MODIPURAM MEERUT UP 250110 | MEERUT | MEERUT | UP | 250110 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹26.6 L+₹1.1 L (4.32%)Rejected-Finance 54 10 C JAI DEVI NAGAR MEERUT 250 110 UP | MEERUT | UTTAR PRADESH | 250110 | L2 | Rejected-Finance In order but L2. | |
| 3 | L3₹27.3 L+₹1.7 L (6.70%)Rejected-Finance 91 DEFENCE ESTATE PHASE II NEAR AMBEDKAR PARK DEORI ROAD AGRA UP | AGRA | UTTAR PRADESH | 282001 | L3 | Rejected-Finance In order but L3. | |
| 4 | L4₹27.5 L+₹2.0 L (7.67%)Rejected-Finance 159 SHIV NAGAR MODIPURAM MEERUT 250 110 UP | MEERUT | MEERUT | UTTAR PRADESH | 250110 | L4 | Rejected-Finance In order but L4. | |
| 5 | L5₹27.9 L+₹2.3 L (9.11%)Rejected-Finance PLOT NO 46 SECTOR PH I 03 GREATER NOIDA UP 201306 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201306 | L5 | Rejected-Finance In order but L5. |
Tender Value
Refer Docs
EMD Value
₹77,500
Closing Date
23 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE Meerut
29J The Mall Road Meerut Cantt Uttar Pradesh 250001
SPL REPAIR TO INTERNAL ROAD OF SN PARK MD OFFRS ACCN UNDER GE (NORTH) MEERUT CANTT
2023_MES_629838_1
94082/MRT/2023-24/E8
Open Tender
Civil Works
Item Rate
120 days
Meerut Cantt
Please refer Tender documents
7 documents required · 7 mandatory
₹500
GE (N) Meerut
₹77,500
Yes
28 Feb 2024
24 Nov 2023
25 Dec 2023
24 Nov 2023
23 Dec 2023
8 Dec 2023
Amount
Preparing the black top surface of roads by brushing with wire brushes for removing caked mud etc and sweeping with brooms and finally fanning cleaned the surface with gunny bags to remove all loose dirt etc and M&L for applying priming/tack coat with bituminous primer (paving bitumen VG 10/30 @ 5kg per 10 Sqm) and laying of bituminous premixed SDAC 30 mm consolidated thickness with paver mixed at hot mix plant with 5.5% of paving binder and rolled to uniform smooth surface, well ramming Rolled with 8 to 12 Tone power roller and compacted to required camber and gradient complete all as specified and directed.
M&L for cleaning the road surface of dirt, oil/grease and foreign material etc and applying 2.5 mm thick road marking strips(retro reflective) of white/yellow colour using Hot Thermoplastic material by fully/semi automatic thermoplastic paint through authorised applicator complete all as specified and directed.
M&L for Repair to potholes any depth, not exceeding 1 sqm each including sweeping free from dust and mud or water scoring sunken surfaces in roads, paths, etc. cutting around edges to at least 25 mm in depth, making good by applying a tack coat of paving bitumen VG 10/30 @ 5 kg/10 sqm, putting in premixed bituminous macadam carpet well rammed & sealed with binder VG 10/30 @ 9.8 kg/10 sqm, binder with 0.09 Cum of stone chippings, 6.3mm size and again well rammed (including supply of premixed macadam, binder and chippings) depth of pot holes exc 30mm complete all as specified and directed.
M&L premix bituminous macadam mixed with paving bitumen VG 10/30 4% binder content any penetration laid/rolled and compacted to required gradients and camber (Consolidated thickness n.exc 75mm) with 8 to 10 Ton power roller complete all as specified and directed.
S&F in repair Long Solar Delinator made out of medium grade MS pipe 75mm dia, 1.20 Mtr height (0.90 above ground level and 0.30 below ground level) wrapped with three Nos high intensity reflection tape in red, yellow, white in colour of 150 mm height and 50 micron thickness of each. Reflected portion covered with welded mesh of 3mm wire dia and 50mm x 50mm mesh including necessary painting, excavation and embedding in PCC (1:2:4) block size of 250 mm x 250 mm x 350 mm all complete as specified and directed. Make-3M (ID-IE51058819) Solar Vertical Delinator or of equivalent make as approved by GE.
S&F in repair long delinator made out of Medium grade MS pipe 80mm dia, 1.10 Mtr heigh (0.80m above ground level and 0.30m below ground level) wrapped with three Nos high intensity reflection tape in red, yellow and white in colour of 150 mm height and 50 micron thickness of each. Reflected portion covered with welded mesh of 3mm wire dia and 50mm x 50mm mesh including necessary painting, excavation and embedding in PCC (1:2:4) block size of 250 mm x 250 mm x 350 mm complete all as specified and directed. Make - Oscar (Model-OS-801), 3M, TATA BP Solar or equivalent as approved by GE.
S&F in repair Bi-Directional Reflective type Road Sollar Studs, illuminated (100mmx90mmx17mm) yellow/red both sides of rectangular/square shape made out of thermoplastic body fixed on road with bitumen adhesive as per manufacture's instructions having abrasion resistance Ceremic coating and reflective surface complete all as specified and directed. Make - 3M (ID-31928514) SOLAR STUDS or of equivalent make as approved by GE.
S&F in repair cat eyes ABS body with scratch and abrasion resistant, micro prismatic, polycarbonate and ultrasonically welded lenses of temperature resistance body of size 100mmx90mmx17mm fixed on road with bituminous adhesive as per manufacturer's instructions having abrasion resistance cereamer coating and reflective surface complete all as specified and directed. Make - 3M (ID-28994191) ROAD STUDS (CAT EYES RAISED PAVEMENT MARKER SERIES 290 COLOUR - RED AND YELLOW or of equivalent make as approved by GE.
S&F in repair convex mirror 100cm outer dia having 80mm dia MS pipe post medium grade 2.5m long including necessary fixing arrangements, excavation and earth work in soft/loose soil, foundation in PCC 1:2:4 type D-2 of size as 30cmx30cmx40cm complete all as s[ecified and directed. (Make - Oscar (Model-OS-790) or equivalent as approved by GE).
S&F in repair Stainless steel Sign Board of Size 4'x3' supported on legs 50 mm dia stainless steel 304 grade pipe of height 80" on each side of road with 4'x3' SS square pipe frame of diameter 1 inch including 3mm ACP Sheet both side visibility digital HP print as per art work reflective (as directed by GE) incl excavation for post hole and M&L for embedding in PCC block 1:3:6 type (C-2 using 40 mm graded stone aggregate) of size 350 x 350 x 450 mm complete all as specified and directed.
Surface excavation in soft/loose soil as in berms dressing not exc 30 cm and averaging 15 cm deep and getting out complete all as specified and directed.
Removing excavated material not exc .50 and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
M&L for 75mm thick cement concrete 1:4:8 type D-2 using (40mm graded stone aggregate) as in sub base complete all as specified and directed.
M&L sand for cushioning including spreading and levelling in layers not exc 25mm thick complete all as specified and directed.
M&L 80mm thick M-40 grade machine pressed precast concrete coloured interlocking paver block shape & size conforming to IS-15658/2006 with pigment over sand cushioning, interlocking paver block jointed filled with sand complete all as specified and directed. Note:- Sand cushioning shall be measured & paid separately.
Punit Jain
Gupta Automobiles
Arun Construction Co.
Shri Kanchan Engineers
Maa Vaishno Enterprises
G. K. CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .