Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 CrAdmitted-Finance | ₹2.3 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.6 Cr+₹24.5 L (10.6%)Admitted-Finance | ₹2.6 Cr+₹24.5 L (10.6%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | SHARAT PURI CONTRACTORS L2 | Kasana Brothers L1 |
|---|---|---|---|---|---|
| 1.00 | 2.7) Earthwork in excavation by mechanical means (hyraulic excavator) over areas (exceeding 30cm in depth, 1.5mtr in width as well as 10sqm on plan) including disposal of excavated earth, lead upto 50m and lift uptp 1.5mtr, disposed earth to be levelled and neartly dressed in all kinds of soil. | 108.76 | Cum | 180 ₹19,576.8 | 148.25 ₹16,123.67 Lowest |
| 2.00 | 2.9) Earthwork in excavation by Mechanical means (Hydraulic Excavator) in foundation trenches, drains, pipes and cables etc. (not exceeding 1.5Mtr. In width or 10Sqm on Plan) including dressing of sides and ramming of bottom, lift upto 1.5Mtr. Including getting out excavated soil and disposal of surplus soil as directed within a lead of 50Mtr. in all kind of soil. | 22.49 | Cum | 180 ₹4,048.2 | 150 ₹3,373.5 Lowest |
| 3.00 | 4.4.8) Providing & Laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work upto plinth level 1:4:8 (40mm nominal mix crushed). | 6.01 | Cum | 4,500 ₹27,045 | 3,412.8 ₹20,510.93 Lowest |
| 4.00 | 5.49) Providing & Laying icement concrete 1:4:8 (1 cement:5 Coarse Sand:10 graded brick agg. 40mm nominal size) in retaining wall/ return wall, columns etc. excluding cost of centering & shuttering all work upto floor V level | 106.2 | Cum | 3,330 ₹3,53,646 | 2,500 ₹2,65,500 Lowest |
| 5.00 | 5.1) Providing & laying in position cement concrete of specified grade excluding the cost of centering & shuttering all work upto plinth level 1:1.5:3 (1 cement: 1.5 Coarse sand: 3 Graded stone agg.) 20mm nominal mix crushed. | 53.51 | Cum | 8,000 ₹4,28,080 | 5,504.2 ₹2,94,529.74 Lowest |
| 6.00 | 5.2) Reinforcement cement concrete work in walls (any thickness) including attaches pilasters, buttresses, plinth and string course, fillets, columns, pillar, piers, abutments, posts and struts etc upto floor 5 level excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement: 1.5 Coarse sand: 3 Graded crusher stone agg. 20mm nominal mix. | 148.9 | Cum | 8,000 ₹11,91,200 | 5,500 ₹8,18,950 Lowest |
| 7.00 | Providing & laying reinforced cement concrete 1:1.5:3 (1 cement: 1.5 Coarse Sand: 3 graded stone agg. 20mm nominal size) in suspended floors, balconies, landings and staircase having slope upto 15' slope, excluding cost of centering & shuttering, all work upto floor 5 level. | 45.76 | Cum | 8,000 ₹3,66,080 | 5,500 ₹2,51,680 Lowest |
| 8.00 | 5.5) Reinforced cement concrete work in arches, archribs, domes, vaults shells, folded plate and roofs having slope more than 15° upto floor five level level including curing but excluding the cost of centering, shuttering finishing and reinforcement with: 5.5.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size). | 1.58 | Cum | 8,000 ₹12,640 | 6,033.05 ₹9,532.22 Lowest |
| 9.00 | 2.11) Filling available excavated earth (excluding Rock) in trenches, plinth, sides of foundation etc. layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering lead upto 50Mtr. And Lift upto 1.5Mtr. | 562.13 | Cum | 90 ₹50,591.7 Lowest | 102.2 ₹57,449.69 |
| 10.00 | 5.22) Reinforcement for RCC work including straightning, cutting, bending, placing in position and binding all complete (TMT Bars) | 46,375.52 | Kg | 88 ₹40,81,045.76 | 65 ₹30,14,408.8 Lowest |
Tender Value
₹2.7 Cr
EMD Value
₹5.5 L
Closing Date
27 Jan 2021, 4:00 pmClosed
Er. Arshad Mir
Office of the Deputy General Manager, JKPCC Ltd., Unit 8th Rajouri.
Construction of Balance work of Multipurpose Indoor Sports Hall at Mandi Poonch (complete job).
2021_PWDJK_113115_1
e-NIT No. 16/Rajouri of 2020-21 Dt. 05-01-2021.
Open Tender
Civil Works
Item Rate
120 days
POONCH
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,000
Yes
Financial Controller, JKPCC Ltd.
₹5.5 L
Yes
O/o Executive Director, JKPCC Ltd., Jammu
1 Mar 2021
5 Jan 2021
29 Jan 2021
5 Jan 2021
27 Jan 2021
6 Jan 2021
11 Jan 2021
Amount
2.7) Earthwork in excavation by mechanical means (hyraulic excavator) over areas (exceeding 30cm in depth, 1.5mtr in width as well as 10sqm on plan) including disposal of excavated earth, lead upto 50m and lift uptp 1.5mtr, disposed earth to be levelled and neartly dressed in all kinds of soil.
2.9) Earthwork in excavation by Mechanical means (Hydraulic Excavator) in foundation trenches, drains, pipes and cables etc. (not exceeding 1.5Mtr. In width or 10Sqm on Plan) including dressing of sides and ramming of bottom, lift upto 1.5Mtr. Including getting out excavated soil and disposal of surplus soil as directed within a lead of 50Mtr. in all kind of soil.
4.4.8) Providing & Laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work upto plinth level 1:4:8 (40mm nominal mix crushed).
5.49) Providing & Laying icement concrete 1:4:8 (1 cement:5 Coarse Sand:10 graded brick agg. 40mm nominal size) in retaining wall/ return wall, columns etc. excluding cost of centering & shuttering all work upto floor V level
5.1) Providing & laying in position cement concrete of specified grade excluding the cost of centering & shuttering all work upto plinth level 1:1.5:3 (1 cement: 1.5 Coarse sand: 3 Graded stone agg.) 20mm nominal mix crushed.
5.2) Reinforcement cement concrete work in walls (any thickness) including attaches pilasters, buttresses, plinth and string course, fillets, columns, pillar, piers, abutments, posts and struts etc upto floor 5 level excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement: 1.5 Coarse sand: 3 Graded crusher stone agg. 20mm nominal mix.
Providing & laying reinforced cement concrete 1:1.5:3 (1 cement: 1.5 Coarse Sand: 3 graded stone agg. 20mm nominal size) in suspended floors, balconies, landings and staircase having slope upto 15' slope, excluding cost of centering & shuttering, all work upto floor 5 level.
5.5) Reinforced cement concrete work in arches, archribs, domes, vaults shells, folded plate and roofs having slope more than 15° upto floor five level level including curing but excluding the cost of centering, shuttering finishing and reinforcement with: 5.5.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size).
2.11) Filling available excavated earth (excluding Rock) in trenches, plinth, sides of foundation etc. layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering lead upto 50Mtr. And Lift upto 1.5Mtr.
5.22) Reinforcement for RCC work including straightning, cutting, bending, placing in position and binding all complete (TMT Bars)
5.9) Providing & fixing Formwork including centering, strutting, propping etc. and removal of formwork for
Foundations
Suspended Floors, roofs, landing, balaconies
Lintels, beams,Plinth beams, girders, bressumers & Cantilevers
Edges of slabs & breaks in floors & walls
Columns, Pillars, Piers, Abutments, Struts
Walls any thickness including attached pillars, buttress and plinths
Stairs steps spiral stairs
Weather shade, Chajjas, corbles including edges
4.17) Providing and laying DPC 40mm thick cement concrete 1:2:4 (1 cement: 2 Sand: 4 Graded stone agg. 12.5mm size)
6.1) Brick work with commom burnt clay FPS non modular bricks of class designation 75 in F/D and plinth in cement Mortar 1:6 (Hall, Sitting area, first floor)
6.15) half Brick thick masnory with bricks of class designation 75 in foundations and plinth in 1:4 ratio
9.1) Providing wood work in frames in doors, windows, clestory windows and other frames, wroght frammed and fixed in position with holdfast lugs or with Dash fastners or Required dia and length: SAL Wood
9.6)Providing & fixing panelled or panelled & galzed shutters for Doors, windows clerstory windows including ISI marked MS pressed BUTT hinges Bright finished or required size with necessary screws excluding panelling which will be paid seperataly, all complete as per direction of Engineer In Charge. Second class Deodar Wood 35mm thick
13.1) 12mm cement plaster of mix 1:4 with making of Groove between brick work & RCC
13.2) 15mm thick plaster of mix 1:6 with making of groove between brick & RCC
13.3) 20mm thick plaster of mix 1:6 with making of groove between brick & RCC
2.23) Supplying & filling in plinth with fine sand under floors including watering, ramming, consolidating and dressing complete
11.52) Providing & Laying vitrified floor tiles in different sizes (Thickness to be specified by the manufacturers) with water absorption less than 0.08% and conforming to IS: 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 including pointing of joints with white cement and matching pigment etc, complete
11.50) Providing & fixing cermic glazed tiles 300x300mm (thickness to be specified by the Manufactures) of IST quality conforming to IS: 13755 of NITCO, Orient, SOMANY, KAJARIA or equivalent make in clours such as white, ivory, grey, fume red, brown laid on 20mm thick cement mortar 1:4 including pointing of joints with white cement and matching pigment etc.
Providing & fixing Antskid floor tiles for ramp 300x300mm (thickness to be specified by the Manufactures) of IST Quality conforming to IS: 13755 of NITCO, Orient, SOMANY, KAJARIA or equivalent make in clours such as white, ivory, grey, fume red, brown laid on 20mm thick cement mortar 1:4
11.50) Providing & fixing cermic glazed tiles conforming to IS: 13753 of minimum thickness 5mm of approved make like NITCO, Orient, SOMANY, KAJARIA or equivalent make in clours shades except Bergundy, Bottle Green, Black of any size as approved by Engineer in Charge in skirting, Risers of steps & Dados over 12mm thick base cement Mortar 1:3 and jointing with cement slurry@ 3.3Kg/Sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing & laying water proofing treatment to vertical and Horizontal surface of depressed portions of W.C Kitchen and the like consisting of i) IST course of applying cement slurry @ 4.4Kg/Sqm mixed with water proofing compound conforming to IS: 2645 in recommended proportions including rounding of junctions of vertical and horizontal surface. ii) 2nd course of 20mm cement plaster 1:3 mixed with water proofing compound in recommended proportions including rounding of junctions of verticals and horizontal surface. iii)3rd course of applying blown or residual bitumen applied HOT at 1.7Kg/Sqm of area. iv) 4th course of 400 MICRON thick PVC sheet (overlaps at joints of PVC should be 100mm wide and pasted to each other with Bitumen @ 1.7Kg/Sqm.
Providing & laying integral cement based water proofing treatment including preparation of surfaces as required for treatment of roofs, Balconies, terracies etc. constructio of following operations: a) applying a slurry coat of neat cement using 2.75 Kg/Sqm of cement admixed with water proofing compound conforming to IS: 2645 & approved by Engineer in charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying bricks bats with mortar using broken bricks/ brick bats 25mm to 11.5mm size with 50% of cement mortar 1:5 Admix with water proofing compound conforming to IS: 2645 & approved by Engineer in charge to required slope & treating similarity the adjining walls upto 300mm height including rounding of junctions of walls & slabs.
Providing Gola 75x75mm in cement concrete 1:2:4 including finishing with cement mortar 1:3 as per standard Design in 75x75mm deep chase.
Making khurras 45x45cm with average minimum thickness of 5cm cement concrete 1:2:4 (1 cement: 2 sand: 4 Graded stone agg. Of 20mm nominal size) over PVC sheet 1Mx1Mx400 Micron,Finshed with 12mm cement plaster 1:3 & a coat of neat cement, rounding the edges & making & finishing the outlet complete.
Providing & fixing 1mm thick MS steel door with frame of 40x40x6mm angle iron and 3mm MS Gusset plates at the junctions and corners, all necessary fittings complete, incl. applying a primer coat of approved steel primer using MS angle 40x40x6mm for Diagonal braces
Making plinth protection 50mm thick cement concrete 1:3:6 over 75mm Bed of Dry Brick Ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth
Providing & applying white cement based putty of average thickness 2mm, of approved brand and manufacture, over the plastered wall surface to prepare the surface even & smooth
Applying one coat of water thinable cement primer of approved brand and manufacture on wall surface water thinable cement primer (interior)
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50Gram/ Litre of approved brand and manufacture, including applying additional coats where ever required to even shade and colour two coats.
Applying one coat of water thinable cement primer of approved brand and manufacture on wall surface water thinable cement primer (Exterior)
Finishing wall with arcylic smooth paint of required shade on New work (two or more coats applied @ 1.67 Ltr/1.0 Sqm over and including base coat of water proofing cement paint applied @ 2.2Kg/10Sqm)
Applying priming coat with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard & soft wood)
Painting with synthetic enamel paint of approved brand & manufacture to give an even shade on wood work two or more coats on new work
Painting with ready mixed synthetic enamel paint of approved brand & manufacture in all shades to give an even shade on new steel work (two or more coats)
Providing 40x5mm flat iron hold fast 40cm long including fixing to frame with 10mm diameter bolts, Nuts & wooden plugs and bedding in cement concrete block 30x10x15 1:2:4 mix.
Providing & fixing Galvanised wire mesh of average width of apperture 1.4mm and nominal dia of wire 0.36mm in aluminium door , window, ventilator, shutters etc., with EPDM Rubber/ Neoprene Gaskets etc. complete as per the Architectural designs and the directions of Engineer in charge (cost of aluminium snap beeding shall be paid in basic items)
Providing & fixing ISI marked aluminium butt hinges ISI marked anodised (Anodic coating not less than grade AC 10 as per IS: 1868) Transparent or dyed to required colour or shade with necessary screws etc. complete (75x63x3.2mm)
Providing and fixing ISI marked aluminium tower bolts ISI marked anodised Transparent or dyed to required colour or shade with necessary screws etc. complete (150x10mm)
Providing & fixing ISI marked aluminium butt hinges ISI marked anodised (Anodic coating not less than grade AC 10 as per IS: 1868) Transparent or dyed to required colour or shade with necessary screws etc. complete (125mm)
Providing & fixing ISI marked aluminium sliding Door bolts ISI marked Anodised Transparent or Dyed to required colour or shade with necessary screws etc completed 300x16mm
Providing and fixing ISI marked aluminium tower bolts ISI marked anodised Transparent or dyed to required colour or shade with necessary screws etc. complete (300x10mm)
Providing and fixing ISI marked aluminium tower bolts ISI marked anodised Transparent or dyed to required colour or shade with necessary screws etc. complete (450mm)
Providing & fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete
Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position & applying a priming coat of approved steel primer all complete.
Providing corrugated colour GS sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required 0.60mm thick with zinc coating not less than 350gram/Sqm.
Providing & fixing 0.5mm thick plate colour sheet on eves boarding 30cm width of approved colour with necessary fittings & design including all lift, lead, carriage & scaffolding complete.
Prociding and fixing of 7mm to 8mm thick PVC flooring (vinyl indoor sports flooring BWF certified). The flooring shall be a Multi-layer in GEM pattern of thickness 1.5mm followed by fibre layer of better dimession stability of the product. The last layer should consist of foam layer. The flooring to be fixed with water based or rubber based adhesive to ensure better adhesion of the product. The joints of flooring to be thermowelded with PVC welding cord of similar colour. The process to be executed by an hot welding process. it should have all sports properties like shock absorption, ball rebounding etc. product should be BWF certified & IAF approved conforming to EN: 14904 Category P1 with shock absorption of 34%.
Carriage of material including loading, unloading, & stacking complete.
a. Sand by average distance 250Km
b. Aggregate by average distance 15Km
c. Bricks by 250Km
Providing & fixing water closet squatting pan (indian type W.C type) with 100mm sand cast iron por strap, 10 Ltr. Low level PVC flushing cistern including flushpipe (of approved make) "Manually controlled device" (handle lever) conforming to IS: 7231 with all fittings admixtures complete, including cutting and making good the walls and floors wherever required Orissa Pattern white viterous china W.C Pan of size 580x440mm with integral type foot rest.
Providing & fixing water white viterous china pedestal type water closet (European Type W.C) with seat and lid, strap, 10 Ltr low level PVC flushing cistern including flushpipe (of approved make) "Manually controlled device" (handle lever) conforming to IS: 7231 with all fittings admixtures complete, including cutting and making good the walls and floors wherever required Orissa Pattern white viterous china W.C Pan with ISI marked solid plastic seat and lead
Providing & fixing wash basin with CI/MS Brackets, 15mm C.P Brass Pillars Taps, 32mm C.P Brass waste of standard pattern, including painting of fittings & brackets, cutting and making Good the walls wherever required white viterous china basin size 660x460mm with a pair of 15mm C.P brass pillars taps with elbow operated levers.
Providing & fixing of 32mm CP Brass waste coupling for wash basin and sink of approved quality
Providing & fixing PVC waste pipe for sink or wash basin incl. PVC waste fitting complete (flexible pipe 32mm dia)
Providing & fixing white viterous china flat back or wall corner type lipped front urinal basin of 430x260x350mm & 340x410x265mm sizes respectively with automatic flushing cistern with CI /MS Brackets standard size of G.I flush pipe and C.P Brass spreaders with brass unions and G.I clamps complete, including painting of fitting and brackets, cutting & making good the walls and floors wherever required range of two urinal basins with 5 Ltr. PVC white automatic flushing cistern of approved quality.
Providing & fixing 100mm CP Gratings for gully, floor and Nahani Trap
Providing & fixing mirror of superior Glass (of approved quality) and required shape and size with plastic moulded frame of approved make & shade with 6mm thick hard rectangular shape 453x357mm
Providing & fixing 600x120x5mm glass shelf with edges round of supported on Anodised aluminium angle frame with C.P brass brackets and guard rail complete fixed with 40mm long screws, rawl pluges tec. Complete
Providing & fixing toilet paper holder of C.P brass
Providing & fixing PVC pipes of following dia working pressure 6Kg/CM2 of make supreme, finolex or equivalent.
a.160mm dia
b. 110mm dia
c. 75mm dia
Providing & fixing PVC bend of required degree with access door, insertion rubber washer 3mm thick, Bolts and Nuts complete (Finolex, Supreme)
a. 160mm dia working pressure 6Kg/CM2
b. 100mm dia working pressure 6Kg/CM2
c. 75mm dia working pressure 6Kg/CM2
Providing & fixing PVC plain bend of required degree (Finolex, Supreme)
a. 160mm dia working pressure 6Kg/CM2
b. 100mm dia working pressure 6Kg/CM2
c. 75mm dia working pressure 6Kg/CM2
Providing & fixing single plain junction of required Degree with PVC access door, insertion rubber washer 3mm thick bolts & Nuts complete (Finolex, Supreme or Equivalent)
a. 100x100x75mm dia working pressure 6Kg/CM2
b. 75x75mm dia working pressure 6Kg/CM2
Providing & fixing single Unequal junction of required degree with PVC access door, insertion rubber washer 3mm thick bolts & nuts complete
a.100x100x100mm dia working pressure 6Kg/Cm2
Providing & fixing single Unequal plain junction of required degree working pressure 6Kg/CM2 make supreme, Finolex or equivalent. (100x100x75mm)
Providing & fixing PVC offsets working pressure 6Kg/CM2 of make Supreme, Finolex or equivalent
a. 76mm Offsets with 75mm dia pipe
b. 76mm offsets with 100mm dia pipe
c. 152mm Offsets with 75mm dia pipe
d. 152mm offsets with 100mm dia pipe
Providing & fixing PVC Collar (Finolex, Supreme or equivalent)
a. 100mm dia working pressure 6Kg/CM2
b. 75mm dia working pressure 6k?CM2
Providing lead caulked joints to sand cast iron/ centrifugally cast (spun) iron pipes & fittings of diameter.
Providing & fixing trap of self cleaning design with screwd down or hinged grating with or without vent Arm complete, including cost of cutting and making good the walls and floors. (Finolex, Supreme or equivalent)
a. 100mm inlet & 100mm Outlet working pressure 6Kg/CM2
b.100mm Inlet & 75mm Outlet working pressure 6Kg/CM2
Cutting Chases in Brick masnory walls for following dia PVC pipes and making good the same with cement concrete 1:3:6 and 1:4 mortar
a. 100mm dia
b. 75mm dia
Providing & fixing MS Stays & Clamps for PVC Pipes of diameter
a. 100mm dia
b. 75mm dia
Providing & fixing soap Dish (C.P Brass) with Brackets
Providing & fixing towel Ring (C.P Brass)
Providing & fixing G.I Pipes complete with G.I fittings and clamps including cutting and making good the walls.
a. 15mm dia nominal bore (Medium)
b. 20mm dia nominal bore (Medium)
c. 25mm dia nominal bore (Medium)
Providing ^ fixing G.I Pipe complete with G.I pipe complete with G.I fitting including trenches & refilling etc. (External work)
a. 25mm dia nominal bore (Medium)
b. 40mm dia nominal bore (Medium)
Making connection of G.I Distribution branch with G.I Main of following sizes by providing and fixing TEE, incl. cutting & threading the pipe
a. 25 to 40mm nominal bore
Providing & fixing brass ball valve of approved quality conforming to IS: 8931 of 15mm nominal bore
Providing & fixing brass Gate valve of approved quality conforming to IS: 8931 of 20mm nominal bore
Providing & fixing brass gate valve of approved quality conforming to IS:8931 of 25mm nominal bore
Providing & fixing gun metal gate valve of approved quality conforming to IS: 8931 of 32mm nominal bore
Providing & fixing gun metal gate valve of approved quality conforming to IS: 8931 of 40mm nominal bore
Providing & fixing C.P Brass Bib cock of approved quality conforming to IS: 8931 15mm nominal bore
Providing & fixing C.P Brass Long nose Bib cock of approved quality conforming to IS Standards and weighing not less than 810 GMS, 15mm nominal bore
Providing & fixing C.P Jet with connection pipe
Providing & fixing C.P Brass Anglur valve for basin mixture and Geysor points of approved make conforming to IS 8931, 15mm nominal bore
Providing & fixing C.P Brass close hole basin mixer centre hole of approved quality and make weighing not less than 1.97Kg, 15mm nominal bore of standard back type
Providing & fixing Unplasticised PVC connection pipe with brass unions 45cm length & 15mm nominal bore
Constructing brick masnory manholes in cement mortar 1:4, RCC top slab with 1:2:4 mix, foundation concrete 1:4:8 inside plastering 12mm thick with cement mortar 1:3 with floating coat of neat cement complete as per standard design inside 90x80cm and 45cm deep including C.I cover with frame (light duty) 455x610mm. Internal dimession total weight of cover & frame to be not less than 38Kg (weight of cover 23Kg and weight of frame 15Kg) with FPS Bricktion 75s with class designation 75 & with crushed stone agg.
Providing & fixing GI Union in G.I Pipe including cutting and threading the pipe and making long screws etc, complet (new work)
a. 15mm dia nominal bore
b. 20mm dia nominal bore
c. 25mm dia nominal bore
d. 40mm dia nominal bore
Providing & placing on terrace (at all floor levels) Polyethylene water storage tank IS: 12701 marked indicating the BIS license No. with cover and suitable locking arrangement and making necessary holes for Inlet, Outlet and over flow pipes but without fitting and base support for tank (Sintex, Finolex, Electroplast, Star or equivalent) having valid ISI license
Excavating trenches of required width for pipes, cables etc. including excavations for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5m, including getting out the excavated soil and then returning the soil as required, in layers not exceeding 20CM in depth, including consolidating each deposited layer by ramming, watering etc, and disposing of surplus excavated soil as directed, within a lead of 50mtr pipes, cables etc. exceeding 80mm dia but not exceeding 300mm dia
Making chase upto 7.5x7.5 Cm in walls including making good and finishing with matching surface after housing G.I Pipe etc.
Making hole upto 20x20Cm and embedding pipes upto 150mm diameter in masnory and filling with cement concrete 1:3:6 including disposal of mulba
Making soakage pit 2.5mm dia, 3 Mtr. Deep with 45x45Cm Dry Brick Honey comb shaft with bricks of class Designation 75 and S.W drain pipe 100mm dia, 1.8mtr. Long complete as per Standard Design.
Electrical work
Sub-Head (Wiring)
Providing Primary light point wiring using 2 x 2.5mm2 stranded copper/FRLS PVC insulated wires for phase and neutral and 1.5 sq mm green for earth laid in 25 mm Dia. PVC MMS conduit,with modular switch, modular plates & suitable GI Box.Conduits shall be cleated to the surface/walls with saddles and spacers as per engg practice. Rate to include all conduits and accessories, wires. complete and civil works and making good . For point wiring in areas with false ceiling, the point shall be terminated above the false ceiling next to the lighting fixture.(SB Controlled Primary light Points)
Looping above light point ( say secondary light point using 3 x 1.5mm2 stranded copper/FRLS PVC insulated wires laid in 20 mm Dia. PVC MMS conduit;with modular switch, modular plates & suitable GI Box;. . Conduits shall be cleated to the surface/walls with saddles and spacers as per engg practice. Rate to include all conduits and accessories, wires. complete and civil works and making good . For point wiring in areas with false ceiling, the point shall be terminated above the false ceiling next to the lighting fixture.(SB Controlled Secondary light Points)
Providing Primary light point wiring using 2 x 2.5mm2 stranded copper/FRLS PVC insulated wires for phase and neutral and 1.5 sq mm green for earth laid in 25 mm Dia. PVC MMS conduit Conduits shall be cleated to the surface/walls with saddles and spacers as per engg practice. Rate to include all conduits and accessories, wires. complete and civil works and making good . For point wiring in areas with false ceiling, the point shall be terminated above the false ceiling next to the lighting fixture.(DB Controlled Primary light Points)
Looping above light point ( say secondary light point using 3 x 1.5mm2 stranded copper/FRLS PVC insulated wires laid in 25 mm Dia. PVC MMS conduit Conduits shall be cleated to the surface/walls with saddles and spacers as per engg practice. Rate to include all conduits and accessories, wires. complete and civil works and making good . For point wiring in areas with false ceiling, the point shall be terminated above the false ceiling next to the lighting fixture.(DB Controlled Secondary light Points)
Wiring for fan point/ exhaust Fan/call bell point with 1.5 sqmm. FRLS PVC insulated copper conductor single core cable in Surface/ recessed medium class PVC Conduit , with modular switch, modular plate, suitable G.I. box and earthing the point with 1.5sqmm FRLS PVC insulated copper conductor single core cable etc as required.
Wiring for Light /Power Plug with 2 x 4 sq.mm FRLS PVC Insulated Copper Conductor single core cable in surface/Recessed medium class PVC Conduit along with 1 No. 4 sq.mm FRLS PVC Insulated copper conductor single core cable for loop earthing as required.
Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLS PVC insulated copper conductor,single core Cable in surface/Recessed medium class PVC conduit as required.
2 X 2.5 SQ.MM + 1 X 2.5 SQ.MM EARTH WIRE
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
4 X 16.0 SQ.MM + 2 X 6.0 SQ.MM EARTH WIRE
Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required
Supplying and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess,including providing and fixing 3 pin 25 amps modular Multi pin socket outlet with connection,painting etc. as required.
Supplying and fixing Stepped Type Electronic Fan Regulator on the existing Modular Plate Switch Box including Connections but Excluding Modular Plate etc. as Required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Sub-Head (DB's & MCB's)
Supplying and fixing following way,Prewired TP&N PPI Distribution Board of Sheet Steel for 415 Volts on surface/Recess complete with Ready to use DBs - Provided with 100A insulated phase bus-bars,neutral bar/s with shroud/s, earth bar/s , sticking saddles , cement spill protector ,color-coded interconnecting wire set , cable ties , blanking plates and circuit identification labels.The D.B should be IK-09 Compliant.(The Cost of D.B is without MCB's)(IP Rating-43)
6Way (8 Module Incomer),(2+2+2 incomer DP RCCB),(6+6+6) SP MCB's O/G's)
Supplying,Installation ,Testing and Commissioning of Four Pole 415V ,MCB in the existing MCB DB With Connections Testing and Commissioning etc as Required
Supplying and Fixing Following rating,Double Pole (Single Phase and Neutral),240 Volts Residual Current Circuit Breaker (RCCB) having a sensitivity of current upto 300 ma in the existing MCB DB Complete with connections ,testing and commissioning as required.
Supplying and fixing 5 amps. to 32 amps.rating 240 volts 'C' series, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single Pole
Double Pole
Supply and Fixing Single Pole Blanking Plate in the Existing MCB DB complete as Required
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)
Supplying and Laying of B-Class 80 mm Dia Size G.I Pipe under the Road/Floor not less than 1 mtr below the Ground Level including cutting the Road/Floor and making Good the same as required.
Sub Head-IV(Lightning Conductor and Earthing)
ENVIRONMENTALLY SAFE MAINTENANCE FREE EARTHING SYSTEM
Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance value. Supply, installation, testing and commissioning of Advanced Maintenance Free environment friendly Earthing system consisting of 1 no. of 3mtr length, 17.2 mm dia UL certified earth electrode made of high tensile low carbon steel circular rods, molecularly bonded copper on outer surface (minimum copper bonding thickness-250 microns) with GI terminals to connect incoming strips, (Environment friendly backfill compound duly certified as per ANSI/NSF standard 60/Toxic content certificate as safe for use near potable ground water resources strictly as per specification enclosed. Make- SHREE ELECTRODES/OBO BETTERMANN/ERICO
Earth pit chamber (300mm x 300mm) with CI cover for the above.
Providing and Fixing 25 mm x 5 mm Copper Strip in 40 mm dia. G.I Pipe FRL Earth Electrode including connection with Brass nut ,bolt,spring,washer,excavation and refilling etc. as required.
Sub Head -V(SITC of Fans and Fittings)
SITC of Ceiling Fan,Capacitor type suitable for low voltage operation including wiring the down rods of standard length(Upto 30 cm)with 1.5 sq.mm FR PVC insulated,copper conductor,single core cable including providing and fixing phenolic laminated sheet cover on the Fan Box etc as Required.
1200 MM SWEEP
SITC of pre-wired 18 Watt Surface Mounted LED Ceiling Light Fitting including connections with 1.5 sq.mm FR PVC insulated copper conductor single core cable and earthing etc as required.The Light Fixture should have System Efficacy of 85 Lumens/Watt. Note:- The Vendor must supply LM-79 and LM-80 Reports for the Product.
SITC of pre-wired 6 Watt Surface Mounted LED Ceiling Light Fitting including connections with 1.5 sq.mm FR PVC insulated copper conductor single core cable and earthing etc as required.The Light Fixture should have System Efficacy of 85 Lumens/Watt. Note:- The Vendor must supply LM-79 and LM-80 Reports for the Product.
SITC of pre-wired LED Street Light Fixture Bracket Mounted Fitting 90 Watts including connections with 1.5 sq.mm FR PVC insulated copper conductor single core cable and earthing etc as required. The Light Fixture should have System Efficacy of 85 Lumens/Watt. Note:- The Vendor must supply LM-79 and LM-80 Reports for the Product.
SITC of pre-wired Surface Mounted LED Flood Light Fitting 250 Watts including connections with 1.5 sq.mm FR PVC insulated copper conductor single core cable and earthing etc as required.The Light Fixture Should Have System Efficacy of 125 Lumens/Watt.
SITC of pre-wired Surface Mounted LED Flood Light Fitting 350 Watts including connections with 1.5 sq.mm FR PVC insulated copper conductor single core cable and earthing etc as required.The Light Fixture Should Have System Efficacy of 125 Lumens/Watt. Note:- The Vendor must supply LM-79 and LM-80 Reports for the Product.
SITC of pre-wired Surface Mounted LED Flood Light Fitting 80 Watts including connections with 1.5 sq.mm FR PVC insulated copper conductor single core cable and earthing etc as required.The Light Fixture Should Have System Efficacy of 130 Lumens/Watt. Note:- The Vendor must supply LM-79 and LM-80 Reports for the Product.
Supply of AC 230/250 Volts, 50 Hz exhaust fan with louveres of Following Sizes including connection etc. complete as required .
OUTGOINGS MCCB 63 Amps TP+N with Breaking Capacity 18KA with Icu=Ics=100% with Adjustable TMR(03Nos) MCCB 40 Amps TP+N with Breaking Capacity 18KA with Icu=Ics=100% with Adjustable TMR(03 Nos) MCCB 32 Amps TP+N with Breaking Capacity 18KA with Icu=Ics=100% with Adjustable TMR(01 Nos) MCCB 25 Amps TP+N with Breaking Capacity 18KA with Icu=Ics=100% with Adjustable TMR(01 Nos) MCCB 16 Amps TP+N with Breaking Capacity 18KA with Icu=Ics=100% with Adjustable TMR(02 Nos) MCCB 20 Amps TP+N with Breaking Capacity 18KA with Icu=Ics=100% with Adjustable TMR(02 Nos) 5A Capacity Duty Contactor 480 Volts (02 Nos) 12.5A Capacity Duty Contactor 480 Volts (02 Nos) 7% 5 KVAR ,440 Volts Detuned Reactors(02 Nos) 7% 10KVAR ,440 Volts Detuned Reactors(02 Nos) Power Capacitors 7.5 KVAR 480 Volts(02 Nos) Power Capacitors 12.5 KVAR 480 Volts(02 Nos) Load Bearing Members to be made out of 1.6 mm CRCA Sheet. Partitions to be made out of 1.6 mm CRCA Sheet Gland Plates to be 3.0 mm Thick.
Servo Transformer/UPS/Lightning Conductor/Under Ground Cables
Supplying and Laying of 1 No. DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refelling the Trench Etc.as Required .
Supply , loading , Transport ,Unloading , shifting ,laying, testing and commissioning of 11KV/1.1KV Grade XLPE/PVC insulated aluminium/copper multistrande conductor steel of armoured/flexible braid power cables as per the specification. Laying of Cables in horizontal/vertical formation on cable trays, supported along RCC/steel structures if required , pipe racks and cable supports provided,Ground , include unloading, shifting upto site at various location/levels, unpacking & inspection.The scope includes clamping of cables by ready made spacers, saddles or clamps fabricated out of Aluminium strip 3 mm thick along veritacal runs and wherever specified,cutting of the cable as per actual mesurement/cable schedule, Treasing and Clamping of Cable on cable tray velcrow tap of minimum 20mm width or clamping materials in Aluminium or PVC cable tie as per site Conditions.
3.5C x 50 mm² LT XLPE (A2XFY) insulated Aluminium conductor PVC outer sheathed Armoured cable.
Supply and Making end Termination with Brass Compression Gland and Aluminium Lugs for the Following Sizes of PVC insulated and PVC Sheathed/XLPE Aluminium Conductor Cable of 1.1 KV Grade as Required
3.5C x 50 mm² LT XLPE (A2XFY) insulated Aluminium conductor PVC outer sheathed Armoured cable.
Supplying and Installing Following Size of Perforated G.I Cable Tray with Perforation not more than 17.5% in convenient Sections ,joined with connectors ,suspended from the Ceiling including bolts and Nuts ,etc as required.
200mm (W) x 50 mm (H) wide cable tray perforated type
450mm (W) x 50 mm (H) wide cable tray perforated type
Sub Head-VII(ELV)
Supplying,Installation,Testing and Commissioning of I/O Modules Complete with Box,RJ-45 Socket,Front Plate as per the Satisfaction of the Engineer Incharge. (SCHNEIDER/ LEGRAND/ NORTHWEST)
Supplying,Installation,Testing and Commissioning of I/O Modules Complete with Box,RJ-11 Socket,Front Plate as per the Satisfaction of the Engineer Incharge.(SCHNEIDER/LEGRAND)
Supplying and Fixing of Following sizes of PVC Conduit along with Accessories in surface/Recess including painting in case of surface conduit,cutting the wall and making good the same in case of recessed conduit as required.
25mm PVC Conduit
Supplying and Drawing of UTP4 pair CAT-6 LAN cable in the existing surface/Recessed Steel/PVC Conduit as required .
Supplying and Drawing of 3 Plus 1 CCTV cable in the existing surface/Recessed Steel/PVC Conduit as required .
Supplying and drawing 2 pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/PVC conduit as required.
Supply & Erection of Cat-6, 1Mtr Patch Cords complete as per specification and as desired by EIC, Make : AMP/Krone/Schenider
Supply, installation, testing and commissioning of Junction Boxes/DB-20 Pairs with Original Krone module and Back Mount Frame and have Lock -n- key, complete in all respect as per specification and desired by EIC
Supply, installation, testing and commissioning of 20 Pair jelly filled armoured cable of 0.5mm of each Pair Telephone Cable in the existing surface/ recessed steel/ PVC conduit, complete in all respect as per specification and desired by EIC
Supplying,Installation,Testing and Commissioning of 40 Inches Full H.D LED Display Monitor as per the Specifications attached.(SAMSUNG/LG/SONY)
Supply, Installation, Testing and Commissioning of Digital video recorder (DVR) having following features. Input : 16 channel video and audio inputs
Supply, Installation, Testing and Commissioning of 2 Megapixel 1080P Full HD IR Bullet Camera.
Supply, Installation, Testing and Commissioning of 8 TB Surveillance AV Storage Device.
Supply,Installation,Testing and Commissioning of Full Brass Network Connectors and Power Connector
Supply,Installation,Testing and Commissioning of 12V 10A Power Supply Units for Bullet Cameras
SHARAT PURI CONTRACTORS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.54 MB
BOQ_216339.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .