Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.1 LAccepted-AOC | ₹14.1 L Quoted ₹15.0 L | L1 | Accepted-AOC L1 |
| 2 | L2₹21.3 L+₹6.3 L (42.0%)Rejected-Finance | ₹21.3 L+₹6.3 L (42.0%) | L2 | Rejected-Finance L2 |
| 3 | L3₹22.7 L+₹7.7 L (51.6%)Rejected-Finance | ₹22.7 L+₹7.7 L (51.6%) | L3 | Rejected-Finance L3 |
| 4 | L4₹25.9 L+₹10.9 L (72.7%)Rejected-Finance | ₹25.9 L+₹10.9 L (72.7%) | L4 | Rejected-Finance L4 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
8 Dec 2020, 6:00 pmClosed
Shri Niranjan Lal GE(S) BTD
GE(S) Bathinda Bathinda Mil Stn
REPAIR REPLACEMENT OF INTERNAL UNSERVICEABLE POINT WIRING REWIRING REWIRING FITTINGS FIXTURES DBs SUB MAIN WIRING SWITCHES AND CONNECTED ACCESSORIES OF OTM OF SEC II WORKS UNDER AGE EM IV OF GE(S) BATHINDA MIL STN
2020_MES_389987_2
GE(S) BTD-33/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bathinda Mil Stn
AS PER NIT
8 documents required · 8 mandatory
₹500
GE(S) Bathinda
₹50,000
Yes
28 Jan 2021
16 Nov 2020
10 Dec 2020
16 Nov 2020
8 Dec 2020
24 Nov 2020
16 Nov 2020 - 20 Nov 2020
Amount
Taking down carefully existing unserviceable copper / aluminum point wiring (light, fan, socket) complete including removal of unserviceable fittings such as switches, switch-sockets, ceiling roses, etc and removing the retrieved materials from dismantling including making good the disturbed surface of walls, floors, ceilings etc to match with the adjoining work complete all as specified and directed by Engineer-in-Charge.
M&L point wiring for one light point / bell point /ceiling fan point/ exhaust fan point controlled by one switch with 1.5 Sqmm (nominal area) PVC insulated, unsheathed multi strand copper conductor cable FR-LSH in and including concealed PVC conduit 20 mm dia, medium duty, ISI marked including new, steel terminal sunken boxes suitable of modular switch/socket flush to surface for one light point, fan point , controlled by one switch on the same board with other switch or independent including PVC insulated unsheathed 1.5 Sqmm multi stranded copper conductor cable FR-LSH connected to common earth dolly complete including cutting, chasing the surface and then making good the same in CM (1:3) and finishing the surface to match with existing surface etc complete all as specified and directed. (Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of Sch 'A' ).
All as per item No 2 but for socket outlet 5 pin, 6 Amp on same board complete all as specified and directed by Engineer-in-charge.
All as per item No 2 but for socket outlet 5 pin, 6 Amp on independent board complete all as specified and directed by Engineer-in-charge.
All as per srl item No.2 (here-in-before) but for one socket outlet 6 pin, 6/16 Amp with cable of 2.5 Sq mm, multi stranded copper conductor FRLSH cable on the independent board including provision of 2.5 Sq mm PVC insulated unsheathed with single core, multi stranded copper conductor FRLSH cable as earth wire to common earth & connecting to earth dolly complete all as specified and directed by Engineer-in-Charge.
All as per item No 2 here in before but for one light point controlled by two way switch complete all as specified and directed by Engineer-in-Charge.
All as per item No 2 here in before but for call bell point complete all as specified and as directed by Engineer-in-Charge.
M & L for point wiring for one light / fan point controlled by one switch with 1.5 Sqmm (nominal area) PVC insulated, unsheathed multi strand copper conductor cable FR-LSH in existing conduit, and existing sunken boxes but including 3 mm thick phenolic laminated sheet top cover for sunken boxes flush to surface for one light point/fan point, controlled by one switch on the same board with other switch or independent including PVC insulated unsheathed 1.5 Sqmm copper conductor cable FR-LSH connected to common earth dolly complete including cutting, chasing the surface and then making good the same in CM (1:3) complete all as specified and directed by Engineer-in-charge. (Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of Sch 'A' ).
All as per item No 8 but for socket outlet 5 pin, 6 Amp on same board complete all as specified and directed by Engineer-in-charge.
All as per item No 8 but for socket outlet 5 pin, 6 Amp on independent board complete all as specified and directed by Engineer-in-charge.
All as per srl item No. 8 (here-in-before) but for one socket outlet 6 pin, 6/16 Amp with cable of 2.5 Sq mm, multi stranded copper conductor FRLSH cable on the independent board including provision of 2.5 Sq mm PVC insulated unsheathed with single core, multi stranded copper conductor FRLSH cable as earth wire to common earth & connecting to earth dolly complete all as specified and directed by Engineer-in-Charge.
All as per item No 8 here in before but for one light point controlled by two way switch complete all as specified and directed by Engineer-in-Charge.
All as per item No 8 here in before but for call bell point complete all as specified and as directed by Engineer-in-Charge.
S& F switch piano flush type, 6 Amp 240 Volt, AC (ISI Marked) one way etc complete all as specified and directed by Engineer-in-charge.
S& F switch piano flush type, 6 Amp 240 Volt, AC (ISI Marked) two way etc complete all as specified and directed by Engineer-in-charge.
S&F one socket outlet 5 Pin 5 Amp 230 volts AC complete all as specified and directed by Engineer-in-charge. Note:- Switch and socket shall be of same make.
S&F one socket outlet multipurpose( 2-in-1) 3 Pin 5 Amp and 15 Amp AC complete all as specified and directed by Engineer-in-charge. Note:- Switch and socket shall be of same make.
S&F 6 Amps bell push switch, 250 volts, AC ISI marked complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing call bell Ding-dong, 230 Volts AC supply complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing regulator for ceiling fan electronic step type suitable for 1200/1400 ceiling fan complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing ceiling rose surface bakelite 65mm x 50mm, 3 terminals with back plate etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing lamp holder angle/batten complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing LED bulb 5W lamp, 6500K, base B-22 efficancy not less than 90 lumen/watt complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing one module blanking plate of suitable size to fit in distribution board complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing sheet metal enclosures double door made out of CRCA mild steel sheet, flush mounted, acrylic door, 8 way, DB SPN 230 Volts, with 200 Amp rated bus bar, dust and vermin proof suitable for fixing MCB's and Isolators etc including taking down old DB of any type and capacity alongwith MCB etc complete all as specified and as directed by Engineer-in-Charge.
S & F sheet metal enclosures double door made out of CRCA mild steel sheet, flush mounted, acrylic door, 4 way, DB TPN 415 Volts, with 200 Amp rated bus bar, dust and vermin proof suitable for fixing MCB's and Isolators etc including taking down old DB of any type and capacity alongwith MCB etc complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repair MCB, SP, 6 to 32 Amps, 'C' curve, 230 Volts, breaking capacity not less than 10 KA with over load and short circuit protection complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repair MCB, SPN, 32 to 63 Amp, 230 Volts, 'C' curve breaking capacity not less than 10 KA with over load and short circuit protection,50 Hz including necessary attachment complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in repair Isolator TPN, 100 Amp, 415 Volts, 'C' curve breaking capacity not less than 10 KA with over load and short circuit protection,50 Hz including necessary attachment complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in repair Isolator TPN, 63 Amp, 415 Volts, 'C' curve breaking capacity not less than 10 KA with over load and short circuit protection,50 Hz including necessary attachment complete all as specified and as directed by Engineer-in-Charge
Supply, installation and testing of Nursing duty stn call bell with control digital 7 segment LED display panel for 40 Nos call bells, each set with control display panel having each bed indicator of bright red colour and soft ding dong bell on every push of call button and reset push button for each indicator with numeric bed number display having SMPS inbuilt and provision of several number display at a time complete all as specified and directed.
Material and Labour for sub main wiring with 2 single core cable 4 sqmm, 1100 votls grade PVC insulated unsheathed of copper multi strandard conductor FRLSH cable with continuous copper earth conductor single core multistranded PVC insulated FRLSH of size 4 sqmm, 1100 votls grade drawing through in & including PVC concealed conduit medium grade of size 20mm along with accessories such as Tee, elbow, bend etc including taking down old sum in wiring of any type and capacity complete all as specified and as directed by Engineer-in-Charge. Note :- Three runs of cable and one run of PVC conduit shall be measured as one unit.
All as per item No.32 here -in-before but sub main wiring with 2 single core cable 6 sqmm
All as per item No.32 here -in-before but sub main wiring with 2 single core cable 10 sqmm
Material and Labour for sub main wiring with 4 single core cable 16 sqmm, 1100 votls grade PVC insulated unsheathed of copper multi strandard conductor FRLSH cable with continuous copper earth conductor 2 single core multistranded PVC insulated FRLSH of size 16 sqmm, 1100 votls grade drawing through in & including steel corrugated conduit medium grade of size 25mm along with accessories such as Tee, elbow, bend etc including taking down old submain wiring of any type and capacity complete all as specified and as directed by Engineer-in-Charge. Note :- Six runs of cable and one run of steel conduit shall be measured as one unit.
Material and Labour for sub main wiring with 2 single core cable 4 sqmm, 1100 votls grade PVC insulated unsheathed of copper multi strandard conductor FRLSH cable with continuous copper earth conductor single core multistranded PVC insulated FRLSH of size 4 sqmm, 1100 votls grade drawing through existing PVC concealed conduit medium grade of size 20mm along with accessories such as Tee, elbow, bend etc including taking down old submain wiring of any type and capacity complete all as specified and as directed by Engineer-in-Charge. Note :- Two runs of cable and one run of earthing wire shall be measured as one unit.
All as per item No.36 here -in-before but sub main wiring with 2 single core cable 6 sqmm
Supply and fixing in repair 20 (+ 10%) watt Retro LED tube light fitting, wall/surface mounted, IP 20 protection, conforming to IS16106/IS16107, minimum 6000K, 4 feet long polycarbonate body, white , in built LED driver, power factor >0.95, including 18/20 watt tube rod and one batten connecting to electric point by using PVC insulated twin core copper conductor cable of suitable size complete all as specified and as directed .
S & F in repair LED light luminaire 10 (+ 10%) watt 2 ft, efficancy not less than 90 lumen/watt, extruded Aluminium/polycarbonate, PC diffusor and inbuilt driver including electrical connections with not more than 1.5 mtr long twin core round copper conductor cable of suitable size complete all as specified and as directed by Engineer-in-Charge.
S & F in repair LED panel light fitting, ceiling/surface mounted square shaped 36 (+ 10%) watt efficency not less than 90 lumen/watt, extruded aluminium/polycarbonate, PC diffuser and inbuilt driver complete fitting and all other accessories including electric connection connecting with using flexible copper wire twin core complete all as specified and directed . Note:- The rate of LED lamp of 36 watt base is deemed to be included in the quoted rate.Nothing extra shall be paid on this account.
Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (PCC 1:2:4 B-1 using 20 mm graded stone aggregates for concrete pit including 10 mm thick CI cover frame) depth of pit not less than 2.25 m below normal ground level with top edge of the plate not less than 1.5 m below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal / coal dust and common salt filling in alternate layers and connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts check nuts and washers of GI or steel and connecting to earthing test point, main switch board, testing on completion including GI pipe 20 mm dia light grade for watering and bringing out the watering pipe upto 30 cm above the normal ground level plugged at top including all fitting and GI pipe 15 mm dia light grade for the protection of GI wire from earth pit to earth point, all as specified as shown in electrical plate No 3 SSR Part-I and testing on completion including taking down old earthing complete all as specified and as directed by Engineer-in-Charge. Note :- PCC chamber shall be constructed at least 1.5 m away from earth pit pipe for watering shall be provided in slanting manner.
Note for serial item No. 43 to 78:- AARMAN COMPLAINTS/DOOR TO DOOR COMPLAINTS shall be attended on daily basis and no extra charges shall be paid on this account. Also refer Sch 'A' notes in this regard.
S& F in repair switch piano flush type, 6 Amp 240 Volt, AC one way etc complete all as specified and directed by Engineer-in-charge.
S& F in repair switch piano flush type, 6 Amp 240 Volt, AC two way etc complete all as specified and directed by Engineer-in-charge.
S&F in repair one switch 15 Amp 230 volts AC complete all as specified and directed by Engineer-in-charge. Note:- Switch and socket shall be of same make.
S&F in repair 6 Amps bell push AC ISI marked complete all as specified and as directed by Engineer-in-Charge.
S&F in repair one socket outlet 3 Pin 5 Amp AC complete all as specified and directed by Engineer-in-charge.
S&F in repair switch socket combination 2-in-1, 3 Pin 5 Amp and 15 Amp flush type universal complete all as specified and directed by Engineer-in-charge.
S&F in repair one socket outlet multipurpose( 2-in-1) 3 Pin 5 Amp and 15 Amp AC complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repair regulator for ceiling fan electronic step type suitable for 1200/1400 ceiling fan on the existing phenolic laminated sheet etc complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repair buzzer, 230 Volts AC supply complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repair modular switch piano, flush type, one way, 5/6 Amps one module 230 Volts AC complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repair modular switch piano, flush type, one way, 16 Amps one module 230 Volts AC complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repair modular, one socket outlet, 2/3 Pin, 6 Amps 230 Volts AC combined two module complete all as specified and as directed by Engineer-in-Charge. Note:- Switch and socket shall be of same make
Supply and fixing in repair modular, one socket outlet, 2/3 Pin, 16 Amps 230 Volts AC combined two module complete all as specified and as directed by Engineer-in-Charge. Note:- Switch and socket shall be of same make
Supply and fixing in repair modular fan regulator electronic step type (1-4), socket type 230-240 Volt AC supply with frame complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in repair 3mm thick Laminated Hylam sheet cover of approx size 125mmx125mm including fixing of existing switch, socket etc in new sheet complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repair 3mm thick Laminated Hylam sheet cover of approx size 125mmx200mm including fixing of existing switch, socket etc in new sheet complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repair 3mm thick Laminated Hylam sheet cover of approx size 225mmx275mm including fixing of existing switch, socket etc in new sheet complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repair 3mm thick Laminated Hylam sheet cover of approx size 275mmx 325mm including fixing of existing switch, socket etc in new sheet complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repair 10mm thick insulated sheet of approx size 325mmx 325mm fixing of MCCBs and enclosured in main distribution/junction points complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repair 20 (+ 10%) watt Retro LED tube including batten fitting, IP 20 protection, conforming to IS16106/IS16107, minimum 6000K, 4 feet, white , in built LED driver, power factor >0.95, connecting to electric point by using PVC insulated twin core copper conductor cable of suitable size complete all as specified and directed by Engineer-in-charge.
S & F in repair surface mounted, bulk head luminaire comprising of high brightness LED lamp 10/12 Watt, 6000K polycarbonate with IP65 protection, surge protection of minimum 2KV, power factor should be more than 0.90, cool while colour, total hormonic distoration (THD) should not be more than 15% lumen output should not be less than 900 lumens, total input voltage range 140-280V AC, colour rendering Index should not be less than 80 complete including all other accessories and fitting arrangement including electric connection connecting with using flexible copper wire twin core upto ceiling rose/connector complete all as specified and directed by Engineer-in-charge.
S & F in repair LED ceiling light complete, 230 volts 12 Watt LES light fixing on wall/ceiling, the system wattage of fitting should not be more than 12watt + 10% sure protection of minimum 2KV, power factor should be more than 0.90, cool while colour, total hormonic distoration (THD) should not be more than 15% lumen output should not be less than 540 lumens, total input voltage range 140-280V, AC, colour rendering index should not be less than 80 complete with all light fitting connection and connecting with twin core 60 cm long copper conductor FR-LSH cable etc complete all as specified and directed.
S & F in repair energy efficient LED street light of 25 Watt with PDC aluminium body and clear glass with lens for wide beam distribution, top maintainable type with IP 66 degree of protection, PF>0.95 with, fitting should be provided with inbuilt 5KV minimum surge protection, short circuit and over voltage protection facility for driver and fitting including 25 watt LED lamp with GI bracket-01 No, MS clamp-02 Nos suitable for walls/columns metre long twin core round copper conductor cable of 1.50 metre long twin core round copper conductor cable of suitable size and testing complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repair MCCB 4 pole, 230 volt, 63 Amp, 50 Hz with rupturing capacity not less than 16KA, 'C' series complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair MCCB 4 pole, 230 volt, 100 Amp, 50 Hz with rupturing capacity not less than 16KA, 'C' series complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair MCCB 4 pole, 230 volt, 125 Amp, 50 Hz with rupturing capacity not less than 16KA, 'C' series complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair MCCB 4 pole, 230 volt, 160 Amp, 50 Hz with rupturing capacity not less than 16KA, 'C' series complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair MCCB 4 pole, 230 volt, 200 Amp, 50 Hz with rupturing capacity not less than 16KA, 'C' series complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp 240 Volt complete all as specified and as directed by Engineer-in-Charge.
S&F in repair Intergal post top lanterns Moulded plastic capsul which houses lamp holder for 1x10W LED bulb including 1x10W LED bulb and connection of light complete all as specified and as directed by Engr-in-charge.
Supply and fixing in repair rigid non-metallic PVC conduit 25mm dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as plers, lock nuts, saddles, pipe hooks etc. complete all as specified and as directed by Engineer-in-Charge.
Supply and laying or fixing , 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape sheathed twin core 6 sq. mm nominal cross section in service connections including taking down old unserviceable wire complete all as specified and as directed by Engineer-in-Charge.
S&F in repair decorative wall light fixture made up of poly carbonate suitable for retrofit 9 watt LED lamp ( base B-22) complete with PC diffuser and including one 9W LED lamp ( base B-22), 6500K, not less than 90 lumen/watt efficancy including making connection complete all as specified and directed by Engineer-in-charge.
S & F in repair LED panel light fitting, ceiling/surface mounted square shaped 36 (+ 10%) watt efficency not less than 90 lumen/watt, extruded aluminium/polycarbonate, PC diffuser and inbuilt driver complete fitting and all other accessories including electric connection connecting with using flexible copper wire twin core complete all as specified and directed . Note:- The rate of LED lamp of 36 watt base is deemed to be included in the quoted rate.Nothing extra shall be paid on this account.
Supply and fixing environment friendly non intergral flood light LED 180W IP66 with excellent heat dissipation, light in weght and small in size with system high lumen efficancy including fixing with suitable size clamps, nuts bolts, proper connection etc complete all as specified and directed by Engr-in-Charge.
S & F in repair wall mounted LED batten fitting 10 Watt, 6500 K, 0.6m efficancy not less than 90 lumen/watt, extruded aluminium /polycarbonate, PC diffuser and inbuilt driver including electrical connections with not more than 1.5 mtr long twin core round copper conductor cable of suitable size complete all as specified and directed by Engineer-in-charge.
S&F one switch 15 Amp 230 volts AC complete all as specified and directed by Engineer-in-charge. Note:- Switch and socket shall be of same make.
M/S SODHI ASSOCIATES
M/s VISHAL ELECTRIC STORE
NASIB ENGINEERS AND CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .