Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.0 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹52.3 L+₹6.9 L (15.2%)Rejected-Finance NOT AVAILABLE | L2 | Rejected-Finance Other than being lowest | |
| 3 | L3₹54.3 L+₹8.9 L (19.7%)Rejected-Finance | L3 | Rejected-Finance Other than being lowest | |
| 4 | L4₹55.0 L+₹9.6 L (21.1%)Rejected-Finance BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | L4 | Rejected-Finance Other than being lowest |
Tender Value
₹59 L
EMD Value
₹1.1 L
Closing Date
27 Apr 2022, 6:00 pmClosed
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
REPAIR REPLACEMENT MAINTENANCE OF UPS SOLAR STREET LIGHT FITTINGS SOLAR PANEL AND MAINTENANCE OF DG SETS AND SMOKE CHIMNEY AT INHS ASVINI UNDER AGE (I) ASVINI
2022_MES_514977_1
8005/CWE(NW)MUMBAI/E8
Open Tender
Civil Works
Item Rate
330 days
AGE (I) Asvini
Class C and above and category b (I)
7 documents required · 7 mandatory
₹1,000
Yes
AGE (I) Asvini
₹1.1 L
Yes
20 May 2022
23 Mar 2022
29 Apr 2022
23 Mar 2022
27 Apr 2022
13 Apr 2022
23 Mar 2022 - 12 Apr 2022
Amount
Comprehensive maintenance of UPS system upto 3 KVA capacity -9 Nos of any make including attending fault /complaints, checking, repairng and replacement of minor parts i.e Diode, resistor, triode, LED lamps, condenser and minor electronic parts as per existing make as directed and testing after repairing to the satisfaction of Engineer-in-Charge. Note:- (i). The cost of minor parts required for maintenance shall be deemed to be included in the quoted rates. (ii) 2 No of visits shall be made by technician per month and all breakdowns shall be attended as per intimation/ call and the rate coated shall deemed to be included the same and maintaining register for past charged.
Comprehensive maintenance of UPS system 3.5 KVA to 6.25 KVA capacity -12 Nos of any make including attending fault /complaints, checking, repairing and replacement of minor parts i.e Diode, resistor, triode, LED lamps, condenser and minor electronic parts as per existing make as directed and testing after repairing to the satisfaction of Engineer-in-Charge. Note:- (i). The cost of minor parts required for maintenance shall be deemed to be included in the quoted rates. (ii) 2 No of visits shall be made by technician per month and all breakdowns shall be attended as per intimation/ call and the rate coated shall deemed to be included the same.
Comprehensive maintenance of UPS system 20 KVA capacity - 1 No of any make including attending fault / complaints, checking, repairing and replacement of minor parts i.e Diode, resistor, triode, LED lamps, condenser and minor electronic partsas per existing make as directed and testing after repairing to the satisfaction of Engineer-in-Charge. Note:- (i) The cost of minor parts required for maintenance shall be deemed to be included in the quoted rates. ii) 2 No of visits shall be made by technician per month and all breakdowns shall be attended as per intimation/ call and the rate coated shall deemed to be included the same.
Comprehensive maintenance of UPS system 30 KVA capacity - 1 No of any make including attending fault / complaints, checking, repairing and replacement of minor parts i.e Diode, resistor, triode, LED lamps, condenser and minor electronic parts as per existing make as directed and testing after repairing to the satisfaction of Engineer-in-Charge. Note:- (i) The cost of minor parts required for maintenance shall be deemed to be included in the quoted rates. ii) 2 No of visits shall be made by technician per month and all breakdowns shall be attended as per intimation/ call and the rate coated shall deemed to be included the same.
Comprehensive maintenance of UPS system 40 KVA capacity - 1 No of any make including attending fault / complaints, checking, repairing and replacement of minor parts i.e Diode, resistor, triode, LED lamps, condenser and minor electronic parts as per existing make as directed and testing after repairing to the satisfaction of Engineer-in-Charge. Note:- (i) The cost of minor parts required for maintenance shall be deemed to be included in the quoted rates. ii) 2 No of visits shall be made by technician per month and all breakdowns shall be attended as per intimation/ call and the rate coated shall deemed to be included the same.
Supply and fixing in replacement of Commercial UPS system 5.2 KVA capacity, Sine wave, Rated out put power -4420watts, Maximum charging current -21 Amperes, Max VA rating - 3501VA to 5500 VA, Protection - deep discharge, MCB, Over load, shortcircuits, Features - digital display, fast charging, easy UPS bypass, Net Weight - 44.5 Kgs, complete system and testing after replacement to the satisfaction of Engineer-in-Charge including taking down existing system complete all as specified. Make:- Luminous or Equivalent.
Supply and fixing in replacement of solar panel size 1656mm x 991mm x 40mm, 270Wp, 12/24volt, Max voltage power -31.5 Vmp(V), Max current power- 8.57 Imp (A), testing after replacement to the satisfaction of Engineer-in-Charge including taking down existing system complete all as specified and directed by Engineer-in-charge. Make:- Luminous or equvilanet approved make.
Supply and fixing in replacement of solar panel size 600mm x 450mm x 40mm, 40Wp, 12volt, Max voltage power -21.5 Vmp(V), Max current power- 2.48 Imp (A), testing after replacement to the satisfaction of Engineer-in-Charge including taking down existing system complete all as specified and directed by Engineer-in-charge. Make:- Luminous or equvilanet approved make.
Supply and fixing in replacement of Unserviceable UPS battery 12 Volts, 7.2 AH Capacity, sealed maitenance free and uninteruppted life, including taking down old unserviceable battery complete all as specified and as directed. Make:- Amaron Quanta or Equivalent of Exide/Emerson.
All as per Item No 9.00 here in before but for 12 Volts, 18 AH Capacity complete all as specified and directed by Engineer-in-charge. Make:- Amaron Quanta or Equivalent of Exide/Emerson.
All as per Item No 9.00 here in before but for 12 Volts, 26 AH Capacity complete all as specified and directed by Engineer-in-charge. Make:- Exide or Equivalent of Amaron Quanta /Emerson.
All as per Item No 9.00 here in before but for 12 Volts, 42 AH Capacity complete all as specified and directed by Engineer-in-charge. Make:- Amaron Quanta or Equivalent of Exide/Emerson.
Supply and fixing in replacement of Unserviceable solar charging battery 12 Volts, 150 AH Capacity, red charge RC 18000 tall tubular battery, long back up and low maintenance, filled height -503 x 189 x 41, including taking down old unserviceable battery complete all as specified and directed by Engineer-in-charge. Make:- Luminous RC 180000 or Equivalent of Exide/Emerson.
Supply and fixing in replacement of Unserviceable Lead acid Battery 12 Volts, 150 AH Capacity, Inverlast tall tubular battery, High life and low maintenance, including taking down old unserviceable battery complete all as specified and directed by Engineer-in-charge. Make:- Luminous Model No. ILTT 180478 or Equivalent of Exide/Emerson.
Supply and fixing in replacement of FRP solar street light battery box upto 5mm thickness, black colour, weight upto 5Kgs, fixed to pole with MS clamp 25x5 mm duly painted with one coat of red oxide and two coats of silver paint to MS clamp including taking down existing battery box complete all as specified and directed by Engineer-in-charge.. Make: RK Solar system or Equivalent.
Supply and fixing in replacement of Solar LED standloane street light 45 Watts, system volt -24 Volt, Lumens- 4725Lumen, Maximum power point tracking control with in built SCC, SPV Panel - 200wp (100 x 2 Nos), Low maintenance lead acid tubular battery-120AH (2 x60AH), Hot Dip Galvanized tubular pole length - 6 mtr above ground level with base plate and clamps including complete all accessories, Pole/box with clamp duly painted with one coat of red oxide and two coats of Syntheticenamel paint blue/silver colour including taking down existing battery box complete all as specified. Note:- Earth work and PCC foundation shall be measured and paid separately. Make:- Havells/Bajaj/CG.
Supply and fixing in replacement of Mild steel solar street light battery box 5mm to 10mm thickness, surface finished, rectangular shape, single phase, weight - upto10Kgs, fixed to pole with MS clamp 25x5 mm duly painted with one coat of red oxide and two coats of enamel paint blue/silver colour to MS box and MS clamp including taking down existing battery box complete all as specified.
Taking down carefully street light/ flood light/ post top light fittings for repair/replacement of any capacity from 40-200 W and refixing the same after all repair work complete all as specified and directed by Engr-in-charge. Note: Spares shall be measured and paid separately.
Supply only LED driver of 40/45 W LED Street light/Post top/Flood light fitting complete all as specified and directed by Engineer-in-charge.
Supply only LED driver of 60/72 W LED Street light/Flood light fitting complete all as specified and directed by Engineer-in-charge.
Supply only LED driver of 90 W LED Street light/Flood light fitting complete all as specified and directed by Engineer-in-charge.
Supply only LED driver of 100 W LED Flood light fitting complete all as specified and directed by Engineer-in-charge.
Supply only LED driver of 160 W LED Flood light fitting complete all as specified and directed by Engineer-in-charge.
Supply only LED driver of 200 W LED Flood light fitting complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of PVC insulated sheathed multistranded flexible copper conductor cable size 2.5 sqmm x 3 core, drawn through existing conduit / pipe from junction box to fitting complete including taking down old unsv cable all as complete all as specified and directed by Engineer-in-charge.
Supply, laying, testing XLPE insulated screened, PVC innersheathed galvanised steel strip or wire, armoured, heavy duty LT UG electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sqmm x 4 core including taking down existing cable complete all as specified and directed by Engineer-in-charge.
All as per Item No 26.00 here in before but for 16 Sqmm x 4 core complete all as specified and directed by Engineer-in-charge.
All as per Item No 26.00 here in before but for 10 Sqmm x 4 core complete all as specified and directed by Engineer-in-charge.
All as per Item No 26.00 here in before but for 10 Sqmm x 2 core complete all as specified and directed by Engineer-in-charge.
Excavation in trenches not exc 1.5 mtr wide and not exc1.5 mtr in depth for laying of cables etc. in any type of soil and getting out complete all as specified and directed by Engineer-in-charge.
Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in soils complete all as specified and directed by Engineer-in-charge.
Removing excavated material from the site of work to outside MD land complete all as specified and directed by Engineer-in-charge.
Material and labour for dry clean river sand for cushioning of cable in trenches for cable protection including spreading, leveling and hand punning complete all as specified in SSR Part-I and as directed by Engineer-in-Charge. Note :- Only compacted thickness of sand will be measured and paid separately.
Supply, laying un-reinforced precast concrete cable cover class LV type 1 flat size 250mm x 150 mmx 40 mm complete all as specified and directed by Engineer-in-charge.
Cutting existing road surfaces or hard standing 0.45 mtr depth (22 thick comprising bituminuous topping) for laying of pipes/cables and making good disturbed surfaces to match with existing surfaces complete all as specified and directed by Engineer-in-charge.
Material and labour for replacement 50mm High density poly-ethylene pipes (HDPE) of pressure 6 kgf/cm2 pipe, for road crossing of cable or for cable protection laid in trenches or above ground surface after taking out old one all as specified and directed.
All as per Item No.36.00 here in before but for 25mm dia (HDPE) complete all as specified and directed by Engineer-in-charge.
Material and labour for GI pipe, light grade 40mm dia for road crossing of cable for cable protection or above ground surface including taking out old one all as specified and directed.
Material and labour for Replacement of Solar street light Hot Dip Galvanized tubular poles 80mm dia complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified (7.5 meter Long) and applying one coat of steel primer and two coat of aluminium paint and marking pole ser number as per existing number including taking out old corroded/broken pole by cutting or digging complete all as specified and directed by Engineer -in-Charge. Note:- Earth work and PCC foundation shall be measured and paid separately.
Material and labour for Replacement of Post top lantern GI tubular poles 50mm dia, 5 meter Long and applying one coat of steel primer and two coat of synthetic enamel paint (block colour) and marking pole ser number as per existing number including taking out old corroded/broken pole by cutting or digging complete all as specified and directed by Engineer -in-Charge. Note:- Earth work and PCC foundation shall be measured and paid separately.
Material and labour PCC 1:4:8, type D2 (using 40 mm graded granite stone aggregate) as in foundations, filling and mass concrete for steel pole complete all as specified and directed by Engineer-in-charge.
Material and labour PCC 1:2:4, type B1 (using 20 mm graded granite stone aggregate) as in coping for steel pole including necessary formwork complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of street light bracket bend to shape made as required of 40mm dia, 1 mtr long GI pipe light grade fixed to pole/ Wall with flat iron clamp of size 40x6mm two numbers with the help of nuts and bolts for fixing of street light fitting including making all electric connection including taking out old one complete all as specified and directed by Engineer-in-charge.
Material and labour TMT Bars/ Mild steel angle cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated and inclusive of one primer coat, one under aluminium coat and one aluminium finishing coat of paint (for supporting frame for flood light fitting) complete all as specified and directed by Engineer-in-charge.
Scraping old paint from Steel/HDG tubular poles more than 5/7.5 mtr length above ground level including street light arms, applying one coat of steel primer and two coats of synthetic enamel paint (post top lantern to apply block colour and Solar street light pole to apply blue colour) and marking of pole numbers serially with 60 mm circle yellow base sticker and pole serial no written with radium letter in white colour, 150 cm above benching of pole complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of PVC insulated, stranded copper conductor of size 2 x 2.5sqmm + 1 x 1.5sqmm connecting from FRP type looping box to street light fitting connector, passing through steel tubular pole complete with fixing arrangement after taking out old u/s one complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of junction box made from FRP sheet readymade of size 300x200x110 mm including connector blocks four way having suitable size bolt to connect upto 35 sqmm x 3.5 core cable two Nos with the help of suitable gland, thimble nuts, washers supports by flat aluminium clamps not less than 25 mm x 3mm with suitable size nuts, bolts and washers inside and outside looping box including fixing with electric pole and taking out old one of any type complete as directed. Make :- National, Cat ref : NJB2520 or equivalent make as approved by Engr-in-charge.
Supply and fixing in replacement of MCB TPN 32 Amp 10 kA, 415 V, 50 Hz, AC complete. Make: Legrand Cat No. 4086 80 / ABB / Siemens complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of MCB TPN 63 Amp 10 kA, 415 V, 50 Hz, AC complete. Make: Legrand Cat No. 4086 83 / ABB / Siemens complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repair/replacement of Timer switch 3 phase, 63 Amps capacity including power contactor with all accessories as suitable for existing and after taking out unserviceable one complete all as specified and directed by Engineer-in-charge. Make :- (a) Timer switch - Legrand, Cat No 649915, MaxiRex 4QT -1 No. (b) Power contactor - Legrand, Cat No 412544, Nominal rating 25A - 2 Nos.
Taking down old unserviceable Flood light fitting MV/HPSV of any make/wattage and Supply and fixing in Turbo LED Flood light 160watts luminaries with secondary optics made in pressure die-cast housing and heat sink in aluminium extrusion with IP66, complete all as specified and directed by Engineer-in-charge. Make:- Bajaj Cat No-BARFEG 160W LED or Philips/Crompton.
Taking down old unserviceable Post top light fitting of any make/wattage and Supply and fixing in LED Post top lantern 40 watts made in cast aluminium with decorative opal polycarbonate diffuser with IP65 protection, complete all as specified and directed. Make:- Bajaj Celesta Cat No- BGCL 40W LED WH or Philips/Crompton.
Taking down old unserviceable Post top light fitting of any make/wattage and Supply and fixing in LED Post top lantern made in cast aluminium with decorative clear opal acrylic diffuser with IP65 protection, complete all as specified and directed. Make:- Bajaj Arian Cat No- BGCT W4 LED WW or Philips/Crompton.
Taking down old unserviceable Post top light fitting of any make/wattage and Supply and fixing in LED Post top lantern 45 watts made in cast aluminium with innovative glare free indirect lighting distribution and IP65 protection, complete all as specified and directed. Make:- Bajaj Tenco Cat No- BRIL 45W LED NW or Philips/Crompton.
Taking down old unserviceable Bollard/Garden light fitting of any make/wattage and Supply and fixing in LED Bollard offers a high level of durability with high impact resistance. It is easy to install, comes with ingress protection and provides compartable soft lighting complete all as specified and directed. Make:- Philips LED Bollard Cat No- BCP150 LED150/NW PSU 220-240V 7043 or Bajaj/Crompton.
Material and labour for earthing complete with Galvanised steel earth plate eletrode 60cmx60cmx6mm thick buried directly in ground vertically to (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level, connecting to the Galvanised Iron Strip of size 32x6mm size, by means of Bolts, Nuts, Check Nuts and washer made of GI or Steel Earth connecting with test point, provision of Charcal and salt in alternate layers, watering pipe 20mm dia medium grade MS funnel with jali, PCC M-15 Type B-1 in pit with XPM not elss than 4Kg per Sqm and Earthpit with cover returning, filling, removing excavated material all as specified in electrical plate No 3 of SSR Part-I making good excavated surfaces such as hard standing refixing machine pressed precast concrete interlocking paver blocks removed during excavation on earthpit to mach existing surfaces after taking out old/unserviceable one complete and testing on completion all as specified and directed by Engr-in-Charge.
Material and labour for Galvanised iron strip 32 x 6mm burried in ground or fixed on walls/floor with suitable saddles and screws beyond 7.5mtr of earth lead connecting with test point after taking out old/unserviceable one complete all as specified and directed by Engineer-in-Charge.
Supply and fixing test point terminal block for connecting the earth pit and down conductor or Aluminium strip, made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hex head screw after taking out old/unserviceable one complete all as specified and directed by Engineer-in-Charge.
HOT CRANE 5.0 TON CAPACITY:-
Comprehensive maintenance and Material and labour for over hauling of HOT Crane, of 5 ton capacity of bay length 80.0 metres, span 20.0 metres and height of lift 4.0 metres from floor level, situated at AC Plant/ DG Set room to carryimg out monthly maintenance for renewal of unserviceable gears, oiling and greasing the chain pulleys etc, including load test verticality test and deflection test complete all as specified and as directed. NOTE: (a) All miscellaneous items required for satisfactory completion of the job deemed to be included in the unit rate quoted. (b) The contractor has to employ minimum one experienced and trained electrician having full knowledge on cranes and one helper to carry out the regular maintenance once in a month for smooth and effective functioning of Cranes and the cost deemed to be included in the unit rate quoted by the contractor. (c) Technician is responsible for cleaning and maintenance for HOT cranes under monthly maintenance. (d) Necessary tools & plants like ladder etc., required to attend the break down if any, shall be provided by the contractor and the cost is deemed to include in the unit rate quoted. (e) The contractor should submit the identity proof of Technician/Person visiting the site and also responsible for the integrity of the personnel attending the break down and monthly visits. (f) Full load test with 10% over load to be carried out once in the currency of the contract and the rates will be measured and paid under respective item accordingly.
Supply and fixing in repair/replacement of MS chain pulley block 5.0 ton capacity, standard lift-9Mtr, lift speed 2-8mtr/min suitable for HOT crane 5.0 Ton complete all as specified and directed by Engineer-in-charge.
DG SET 1000KVA:-
Disconnecting & removing the unserviceable fan belt from DG set and Supply & fixing new fan belt of same size and capacity of 1000KVA/800KW DG set complete all as directed by the Engineer-in-Charge. Make : Fenner/LUCAS/TVS.
Disconnecting & removing the unserviceable diesel filter from 1000KVA/800KW DG set and Supply & Fix new diesel filter assy, cleaninng filter cell, fixing filter element with rubber gasket complete all as specified and directed by Engineer-in-charge. Make: MICO/Puralator/Bosch.
Supply and filling Engine oil 20W 40 complete all as specified and directed by Engineer-in-charge.Make: Castrol GTX/Greaves Max therm/Kirloskar.
Taking down u/s speed control unit supply and fixing new electronic speed control unit with necessary connection terminal suitable for 1000KVA/800KW DG sets complete all as specified and directed by Engineer-in-charge. Make : Kirloskar /Greaves.
Taking down u/s automatic voltage regulator, supply and fixing new regulator with UVN, PQ, F1F2 terminals rated voltage upto 180 Volts suitable for 1000KVA/800KW DG sets complete all as specified and directed by Engineer-in-charge. Make : Kirloskar/Greaves.
Supply and topping up of coolent complete all as specified and directed by Engineer-in-charge. Make: castrol/ Veedol.
Disconnecting & removing the unserviceable Battery charging unit & Supply and fix new battery charging unit of capacity suitable for 12/24 volts battery and fixing in inside the AMF panel enclosure complete all as specified and directed by Engineer-in-charge..
Taking down old fuel/Oil pipe line with benjo bolt supply and fixing new fuel/oil pipe lines (High pressure rubber pipe covered with steel armoured complete all as specified and directed by Engineer-in-charge.
Taking down self starter assembley from engine for repairs and servicing of starter including replacement of worn out parts complete all as specified and directed by Engineer-in-charge. Note : Spare required will be measured and paid separately under relevant items of the schedule.
Supply only Soleniod switch any type for self starter complete all as specified and directed by Engineer-in-charge.
Supply only Carbon brush set any type with brush holder complete all as specified and directed by Engineer-in-charge.
Supply only Drive End Plunger complete all as specified and directed by Engineer-in-charge.
Rewinding of field coils with existing gauge supper enamelled copper wire complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of unserviceable Lead acid Battery 12 Volts, 180/200AH Capacity, Inverlast tall tubular battery, Super long backup and super long life, including taking down old unserviceable battery complete all as specified and as directed. Make:- Luminous/Exide/Emerson.
Supply and fill in the batteries of DG sets distilled water and acid mix water at different locations complete all as specified and directed by Engineer-in-charge.
Supply and fixing Engine control/protection relay having the auto manual mode, contactor close/open, DG start/stop functions suitable for of capacity 1000KVA/800KW DG sets including taking down u/s protection relay complete all as specified and directed by Engineer-in-charge. Make:- L&T,C&S,Siemens.
Supply and fixing injector over flow pipe including taking down u/s pipe complete all as specified and directed by Engineer-in-charge.
Taking down dynamo assembly from engine for repair/replacement of worn out parts and refixing the same including cheking of proper charging of batteries complete all as directed.
supply and fixing non return benjo bolt including taking down unserviceable benjo bolts complete all as specified and directed by Engineer-in-charge.
Material and labour, dismantling and transporting to the workshop for opening of injectors for servicing and testing & calibration on bench at the authorised dealer / workshop with replacement of injector nozzles and "O" rings and transporting back to the place and refixing the same at the DG set engine complete all as specified and directed by Engineer-in-charge.
Material and labour for opening fuel injection pump for calibaration and tesing on bench and refixing the same after calibaration complete all as specified and directed by Engineer-in-charge.
Disconnection and removing the defective wiring from AMF Panels of any capacity and rewiring the same with copper wire of existing size,gauge and make including replacement of electrical/ electronic parts of AMF panel such as timers, contactors, Overload relays ,Micro prossser control Systems etc. for DG Set of capacity 1000KVA/800KW, complete all as directed by Engr-in-charge.
Supply and fixing Auxilary Contactors (Existing type) with logic units. Make:- L&T/ Siemens/C&S complete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement unserviceable fuel feed pump complete all as specified and directed by Engineer-in-charge.
Material and labour for removing old rusted paint from complete DG Set surfaces of the 1000 KVA capacity & AMF/DG panel complete with one coat of Primer and two coat of spray painting one by one with existing colour paint synthetic enamel type including writing Ser No of DG set complete all as specified and directed by Engineer-in-charge.
Renewal of unserviceable spares for water manifold and Radiator spares 1000KVA DG set for the following spares complete all as specified and directed by Engineer-in-charge.
Radiator rubber hoses complete all as specified and directed by Engineer-in-charge.
Clamp for hump hose complete all as specified and directed by Engineer-in-charge.
Hose clamps complete all as specified and directed by Engineer-in-charge.
Hump hose complete all as specified and directed by Engineer-in-charge.
Drain out the fuel tank of DG set of capacity 1000 Ltrs and above and keeping it in separate container disconnecting all the fuel lines and other mechanical connections and taking out the fuel tank for cleaning, internally and externally by removing all the accumulated dirt/ sediment, leak testing the tank and welding/ brazing including one coat of black synthetic enamel paint, refixing the tank in its original position, replacing the drain plug and PVC pipe protected with steel flexible pipe calibrating the fuel tank, refilling the drained out fuel back into the tank and marking of liters in gauge and provision of locking arrangements complete all as directed by Engr-in-charge.
Removing of defective engine oil control pressure switch supply & fix new engine oil control pressure switch suitable for 1000 KVA DG set of make Kirloskar- Cummins complete all as directed by Engr-in-charge.
Dismantling of exhaust pipe of the 1000KVA DG set by unscrewing nuts and bolts and taking down the pipe with muffler removing the burnt out asbestos rope and well wrapping with new aluminium metal cladding with glass wool including cleaning the silencer, and fixing the same in its original position complete all as directed by Engr- in- Charge.
SMOKE CHIMNEY:-
Complete opening dismantling of chimney hood, smoke duct by removing rusted nut bolts, supports,angles,clamps,brackets,anchor fastners washers etc. Cleaning of complete hood, smoke duct by removing deposited dust particles, ash, smoke, oil by means of cleaning agent, replacement of nut bolt washers, repiras and maintenece of aluminium filter, sheet, replacement of damaged filter, aluminium sheet of suitable gauge of size, oiling, greasing of nut bolt washers, all joints,replacement of worn out smoke duct clothing ,maintenence of blower fan and motor including painting with heat resistant aluminium paint all as directed by E-in- charge.
Taking down carefully blower motor for rewinding with suitable guage, insulating, drying, reinstalling, testing and commissioning of electric blower of capacity 7.5 HP, 3 phase, 240 volts, AC, complete with electrical connection all as directed by Engineer-in-charge .
Supply and fixing in replacement of MU- Automatic DOL starter for 3 phase, 415 volts, 50 Hz , AC Supply , suitable for 7.5 HP motor complete all as specified and directed by Engineer-in-charge.
SHREE JAGDISH FURNITURE CO.
NOEL ENGINEERS
AGRAWAL ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .