SE EUDC-Rajbhawan
Office of the SE EUDC-Rajbhawan
17/EUDC(RB)/LESA/2024-25
2024_MVVNL_939704_1
17/EUDC(RB)/LESA/2024-25
Open Tender
Electrical Works
Fixed-rate
90 days
EUDD RAJBHAWAN Lucknow Central Zone
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
Central bank of india
₹12,000
30 Jul 2024
22 Jul 2024
27 Jul 2024
22 Jul 2024
27 Jul 2024
22 Jul 2024
Amount
Dragging, loading, carriage and unloading of following store materials with proper stacking from ESC Daliganj to JE dumps store and from JE dump store to work site within municipal area.
33 KV VCB 800 Amp. 750 MVA
33 KV Control Pannel single circuit Transformer
33 KV Lightening Arrester 400 Amp.
33 KV LINE Isolator
33KV Current Transformer 200/100/1
33 KV POST INSULATOR
ACSR Panther Conductor for Bus Bar
Fabrication & Erection of cable stand made of two nos MS channel 100x50x3 mtr. Long jointed to each other by means of 05 nos MS strip 50x6 mm of size 150 mm Long each by welding at equal distance interval as per norms and grouting in block of 300x300x700 completely providing two nos cable clamp also.(All materials will provide by contractor icluding MS channel).
Painting of all New&Previously Erected structures equipment.
Construction of masonry type plinth for 33KV VCB of size 1.6x1.6x1 M brick, sand, cement and stone grit including grouting of 4 Nos foundation Bolts for erection of 33KV VCB.
Isolator Structure-Fabrication of Isolator structure minimum 3.5 mtr overall height and 2.5 mtr above ground level as per RESSPO drawing, with help of M.S channel 125x65 mm two pieces of M.S channel joined to each other by M.S flat 50x6 mm, diagonally at the interval of 0.5 mtr and top & bottom of the structure. Grouting of Isolator structure in CC (cement ,coarse sand and stone grit of 20 mm gauge) including supply of necessary T&P and painting os structure complete.(only M.S channel and angle provided by the deptt)
Lightning Arrestor/ CT structure : - Fabrication of lightning arrestor/CT structure as per RESSPO drawing with the help of 2 nos M.S channel 125x65 mm minimum 3.5 mtr long grouting 1 mtr deep from ground level in cc in ratio 1:4:8. complete in all respect.
Erection of structures, grouting, plinthing of ALL structures equipment.
Mounting of accessories/equipment on fabricated structure complete work with making proper alignment and tightening the work includes fabrication work if required for proper operation of equipment .
33 KV VCB
33 KV lightning Arrestors
Bus/Line Isolator
Fabrication & Erection of Neutral Stand structure with foundation
Erection and commissioning of 05 MVA T/F mounting of radiator conservator tank exposure vent etc. Filling of T/F oil in radiator conservator tank with complete work as per RESPO Norms.
Jumpering complete T/F bay with ACSR panther Cond. and required clamp with nut & Bolts from 33KV existing bus bar & 33KV cable to T/F (with copper L piece) complete work.(01 no. T/F bay)
Hoisting, jumpering, clamping of 11KV 3x300 sq mm XLPE cable on cable stand, panel with proper taping with the help of empire tape. PVC tape and connectors.
Construction of Control cable trench of size 150 mm wide 300 mm deep with brick work along with provision trench cover M.S strip at the interval of 0.30 M and M.S angle at both the edge of the trench.
Construction and fixing of trench cover0.5 M wide 0.75 mm thick with cement, coarse sand & stone grit in ratio 1:2:4 for covering of cable trench150 mm wide with provision of M.S Angle and MS Bar as per RESPO Norms
Supply & Laying of copper control cable of following sizes its proper dressing ,ferruling and connection with the system.
Copper Control Cable 2x2.5 Sq. mm.
Copper Control Cable 4x2.5 Sq. mm.
Copper Control Cable 6x2.5 Sq. mm.
Pipe boring type earthing minimum 20 mtr deep from ground level or upto water level with B class G.I. pipe 2 " dia. Connection of equipment with earthing by GI strip 50x6 mm included in the job as per specification/norms for power transformer, VCB, CT/LA and other. (All materials will be Provided by contractor)
Complete work of fixing of inertlocking tils in swithchyard area. (All the materials shall be provided by contracter)
Dragging of following panels (Control and feeder pannel) from unloading place upto control room and placement erection and grouting, commissioning & testing of the same as per RESPO Norms
33 kV T/F Control panel
Supply of following auxiliary material
Rabber mat 2x1.5 Mtr.
supply and fixing on covered sland cooling fan for power transformer
supply and fixing of different type of pg clamp for 33 kv line work
All taxess as applicable shall be paid time to time extra
M/S R P ENTERPRISES
SIDDHI ENTERPRISES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .