Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.6 LAccepted-AOC | L1 | Accepted-AOC being L1 | |
| 2 | L2₹42.4 L+₹47,760.46 (1.14%)Rejected-Finance | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹42.9 L+₹95,812.52 (2.28%)Rejected-Finance 18 KUSHAL LAYOUT 1ST CROSS KAGGADASAPURA CV RAMAN NAGAR POST BENGALURU 560093 | BENGALURU | BENGALURU URBAN | KARNATAKA | 560093 | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹43.3 L+₹1.3 L (3.16%)Rejected-Finance | L4 | Rejected-Finance Rejected being L4 | |
| 5 | L5₹44.2 L+₹2.3 L (5.45%)Rejected-Finance 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BENGALURU URBAN | KARNATAKA | 560085 | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹46.5 L
EMD Value
₹93,000
Closing Date
8 Nov 2023, 6:00 pmClosed
GE I R AND D EAST BANGALORE 93
GE I R AND D EAST BANGALORE 93
REPAIR REPLACEMENT OF AC SHEETS FALSE CEILLING AND ROOF TREATMENT WORKS ALONG WITH REPALCEMENT OF WOODEN STEEL TRUSS AND REPLACEMENT WOODEN SHUTTER IN LIEU OF ALUMINIUM WINDOWS AT MES INSTALLATIONS AND MES RESIDENTIAL COMPLEX AT DFRL MYSORE
2023_MES_622567_1
8433
Open Tender
Civil Works
Item Rate
270 days
GE I R AND D EAST BANGALORE 93
D a(i)
8 documents required · 8 mandatory
₹500
GE I R AND D EAST BANGALORE 93
₹93,000
Yes
7 Feb 2024
10 Oct 2023
16 Nov 2023
10 Oct 2023
8 Nov 2023
25 Oct 2023
11 Oct 2023 - 21 Oct 2023
Amount
Taking down cement plaster of any description, thickness including racking out joints hacking for key scrubbing down with water all as specified and directed
M&L for rendering 15mm thick in cement mortar (1:4) on fair faces of brick work or concrete surfaces & finishing the surface even & rough complete all as specified & directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces of walls in cement mortar (1:6) including finishing the surface even and smooth complete all as specified & directed .
M&L for two coat of cement base paint over New surfaces including preparation of surface all as specified and as directed.
M&L for appying two coats of oil bound distemper on new plastered walls surface over a coat of primer (as per manufacturer instructions) on wall surfaces complete all as specified and directed
Dismantling of ceiling boards and wall (fibre insulation, etc or insulation boards any thickness, including cover fillets including snap grid , hanger etc complete all as specified and directed
S&F Anodised aluminium snap grid 605x605 mm with frame work inculding necessary fixing arrengements of GI wire, clits, hold fasteners etc for false ceiling complete all as specified and directed.
S&F Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions complete all as specified and directed.
Taking down chowkhats or frames with shutter (without taking off shutter from the frame) n. exc 1.50 sqm in each complete all as specified & directed.
Taking down chowkhats or frames with shutter (without taking off shutter from the frame) exc 1.50 sqm but n exc 4 sqm in each complete all as specified & directed.
Dismantling Partition boarding, any description, fixed in any position with nails complete all as specified and directed.
S&F for Anodised Powder Coating (50 Micron thick) Aluminium frame for doors, windows ventilators and Partitions with one or more rebates including joining cleat for fixing etc complete all as specified and as directed
S&F Anodised Powder Coating (50 Micron thick) Aluminium door shutters, aluminium section weighting 0.55Kg/m Including necessary jopining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, higes, anodised aluminium snap beading screws etc, complete all as specified and directed.
S&F Anodised Powder Coating (50 Micron thick) Aluminium window shutters, sliding type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, anodised aluminium fittings such as handle and spring locking system suitable for sling window shutter, screws etc. complete all as specified and directed
S&F Anodised Powder Coating Aluminium ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed
S&F for 4.8 mm thick plain sheet glass exc 0.5 sqm in each pane for aluminium partition and door complete all as specified and directed.
S&F for 4mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane all as specified and directed
M&L for 12mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work all as specified and directed
S&F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed.
S&F Mortice lock, verticaltype, size 100 mm, brass 4 levers complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings all as specified and directed.
S&F for Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed.
S&F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed.
Dismantling of structural steel work in- cluding doors, gates but excluding framed truss etc. all as specified and directed.
S&F for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 all as specified and directed.
S&F for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment, e 410 -W (Gde- E- 250) quality- A complete all as specified and directed.
S&F for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections), Fe-410- W(Gde- E-250) quality - A including distance pieces, cleats etc. all as specified and directed.
S&F Framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railigl framework of watertanks and similar work conforming to Fe-290, Gde E-165 complete all as specified and directed.
M&L for painting to steel surfaces of any description, applying two coats of synthetic enamel paint over a coat of Red oxide including preparation of New steel surface complete all as specified and as directed.
Demolition of cement concrete (un reinforced) Roofs, floors (other than ground floors),beams, staircases, landing,chajjas and similar suspended work all as specified and as directed.
Surface shall be made clean by use of wire brush, Water jet and grinding etc to remove all loose dust, Fungus oils grease etc.All the existing membrane and primer and other foreign particles shall be removed by Grinding and other mechanicals means completely to reach base slab, complete all as specified and directed.
Cutting V shaped groove over the cracks and Filling the Same with Dr. Fixit PU sealant and Pidiprime A , for deeper cracks suitable backerrod shall be provided all as specified and as directed.
Priming : Providing 1 coat of Dr. Fixit Primeseal diluted with clear water at a ratio of 2:1 and allowing it to dry got a minimum of 6 hours. (Dr Fixit Roofseal Ultra plus for Terrace) complete all as specified and directed.
Wherever required concrete work will Providing & laying average 100 mm thick protective coating of M20 garde by keeping minimum 50mm thickness at drainage point slope with 1:100 coating 12 mm with proper slope all as specified and as directed.
Demolition brickwork or stone/boulder masonry, built in cement mortar includng all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles all as specified and as directed.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in Cement Mortar (1:4) complete all as specified and directed.
M&L for Brickwork with sub- class ‘B’ bricks, straight or curved on plan to anyradius in half brick thick walls built in Cement Mortar (1:4) complete all as specified and directed.
S&F 25mm dia Mild steel, PVC coated curtain rails with brackets and complete all as specified and directed.
Supply only PVC curtain Knobs fancy type fixed with sides of curtain rod complete all as specified and directed
Dismantling of water tanks in any type and in any position exc 250 & n. exc 500 ltr capacity all as specified and as directed.
S&F 500 Ltr capacity rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and as directed.
S&F Ball brass 20mm bore valve, high pressure, with polythelene float & flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed.
S & F gun metal globe or gate valve with iron wheel screwed both ends for iron pipe of 20 mm dia complete all as specified and as directed.
M&L for Cement concrete 1:5:10 Type E2(using 40mm graded stone aggregate) in foundations, filling and mass concrete as in sub-bases floors and pavings finishing surfaces of concrete even and rough to receive the topping layer complete all as specified and directed
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
M&L for machine pressed precast concrete Coloured interlocking paver block of any shape and size conforming to IS-15658-2006 of 60mm thickness, M-35 grade with grey cement and no pigment complete all as specified and directed
AMK ENTERPRISES
TECKXPERT ENTERPRISES
AishwaryaConstructions
Lucky Enterprises
Suneetha Engineers and Contractors
SREE VINAYAKA ENTERPRISES
K. VENKATESH NAIDU
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .